Table 8A: Bureau Veritas
Table 8A: Bureau Veritas
TABLE 8A
This has to be verified at site. ** Cement: Fine Aggregate (100% NRS): Coarse Aggregate
Minimum and Maximum Cement Content as Specified by the Customer.
REMARKS: (1) Coarse aggregate shall satisfy the grading requirements as per IS: 383 -2016.
(2)Correction for water absorption of sand and coarse aggregate to be applied at site.
(3)Coarse aggregate of 20mm & 10mm shall be used in the ratio of 50:50 respectively
(4)The mix proportions recommended above should be tried in the field using the proposed materials and finalized by
observing the actual performance of the concrete mix. Suitable modifications may be necessary to suit field conditions
in the light of experience as well as for the particular materials used at the site in each case.
Note : 1. The results relate only to the items tested.
2. Report shall not be reproduced, except in full, without the written approval of the laboratory.
3. Any correction invalidates this report.