MÖLLER 2-Way Diverter Valve

The right direction

Product profile
• Compact design
• Low clearance volume
• Sizes
DN 50 – DN 250
• Temperature-proof up
to 200°C
• 3 methods of operation
– manual
– pneumatic
– motorized
• Direct drive without
linkage
• Long-term service
• Few parts subject towear
and tear
• Simple maintenance
• Simple replacement of
parts subject to wear
and tear
• CE Label
manual operation

2 installation
motor operated
methods

left hard
pneumatically operated

right hard

manual operation motor operated pneumatically operated


DN A B C D E F G H K C D C D
clear width max max
50 50 - 64 460 773 792 410 290 100 330 373 385 580 373 519
65 64 - 76 500 809 836 450 315 115 370 408 500 615 408 560
80 76- 95 550 835 837 500 325 115 420 425 515 612 425 556
100 95 - 119 600 875 858 550 355 125 460 473 525 622 473 576
125 119 - 143 650 922 871 600 375 150 540 510 560 637 510 592
150 143 - 168 800 931 943 710 350 150 560 500 560 699 500 649
175 175 - 200 900 1179 1167 800 445 170 620 620 665 751 620 740
200 183 - 210 950 1196 1202 850 435 185 710 623 665 783 623 761
250 228 - 260 1100 1250 1279 1000 425 240 900 650 685 832 650 803

subject to change.

Use conveying operations have of the 2-way diverter valve. The


Power plants, cement and been stopped. seal on the plate is selfadju-
metallurgic industry, and indu- sting.
strial uses where powdery, Economic operation The coating on the plate means
fine-grained, and granulated Minimal wear and tear due to a low friction and a smooth slide;
bulk material must be convey- small deflection of only 25° in the lap-in process means a
ed and distributed. the casing. long-term certain seal.
Simple diversion switchover by A wide overlap between the
Applications rotating an adapter at the inlet plate and the outlet opening
Diversion of pneumatically ensures long-term service of
conveyed bulk material to the crosshead guide and the
various reception points, e.g., sealing plate.
silo facilities. The 2-way diver- Simple inspection of all inner
ter valve can be installed hori- parts due to bottom cover.
zontally or vertically Where experience and Maintenance and repair work
innovation meet can be carried out without dis-
Operation mantling the 2-way diverter
A sealing plate is activated by a MÖLLER valve out of the pipeline.
shaft and a lever, changing its Materials Handling GmbH The few parts subject to wear
position. The 2-way diverter Haderslebener Straße 7 and tear can easily be replaced
valve has a straight passage D-25421 Pinneberg, through the bottom inspection
and a branch pipe mounted on Germany cover.
the left or right, depending on Tel. +49-4101 788-0
the pipeline course. One of the Fax +49-4101 788 140 Operating reliability
two passages is always com- E-Mail: mmh@moeller-mh.com • Sturdy housing made of cast
pletely closed. Internet: http://www.moeller-mh.com iron
The inside diameter of the 2- • Proven actuators from repu-
way diverter valve corresponds table manufacturers
to that of the pipeline. A swit- • Parts subject to wear and
chover shall be done only when tear are built to last