Refractory Lining
Oct,2011
page 1 of 26
Technical Specification
Refractory and Insulating Linings
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 2 of 26
Technical Specification
Refractory and Insulating Linings
Contents:
1. General
1. General
This technical specification is the basis for procurement and/or supply of the refractory
and insulating linings. It contains the required technical data and information.
Details on the build-up of the walls and the allocation of qualities within the different plant
sections have been given in the relevant separate material specifications (item 3 below
refers).
The suggestions for lining given by us under item 3) below are exclusively based on
qualities that have stood the test in the cement industry. The quality data have been taken
from the catalogs of well-known refractory producers and given as average values.
Obviously, there are alternatives to our suggestions. However, it would go beyond the
scope of this document to comment on all opportunities.
The chemical and physical properties we have specified, in particular, abrasion and alkali
resistance as well as thermal shock resistance shall be duly observed.
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 5 of 26
kiln hood
1000 – 1200°C
(without radiation heat from the kiln)
Important information:
• For balancing the thermal expansions between the cyclone stages, the ceilings
of the cyclone stages are operating according to the principle of a membrane.
When reaching operating temperature, the cyclone ceilings return into their
horizontal position. In this way, the thermal expansions between the cyclone
stages can be balanced without additional compensators.
After the installation of the bricklining and the insulating lining, this basic
operating mode must be ensured.
During the assembly, the cyclone ceilings are lifted, e.g. preloaded, see BA 412-
1505 with drawing ZD 412-241 D/E. Then, the refractory and insulating lining is
installed.
The working sequence, i.e. first preloading, then installing, must be observed.
• The maximum plate temperature of all components in the area of the preheater
must not exceed 140 degrees centigrade.
Preconditions are an intact refractory lining and „normal operation“ of the plant.
Information on the operating temperatures of the different components have
been given under item 2.2) above.
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 9 of 26
The following qualities are recommended. Quality data see chapter 5.:
wall system:
working 1st 2nd
component total
lining insulation insulation
main part type thickn. type thickn. type thickn. thickn.
bricks castable mm mm mm mm
2xStage I
roof - FC1 160 - - - - 160
spiral, straight - FC1 65 IP1 25 - - 90
spiral, inclined - FC1 65 IP1 25 - - 90
walls, round - FC1 65 IP1 25 - - 90
cone - FC1 65 IP1 25 - - 90
star for stage I - FC1 80 - - - - 80
2xGas duct II-I
adapter element - FC1 65 IP1 25 - - 90
bend - FC1 115 - - - - 115
walls, round FB1 - 115 - - - - 115
cone - FC1 115 - - - - 115
2xStage II / top section
roof - FC1 150 IP1 80 - - 230
spiral, straight FB1 - 115 IP1 100 - - 215
spiral, inclined - FC1 115 IP1 100 - - 215
walls, round FB1 - 115 IP1 100 - - 215
2xStage II / bottom section
cone FB1 - 115 IP1 100 - - 215
cone tip - FC1 115 IP1 100 - - 215
2xBend III-II
roof - FC1 150 IP1 80 - - 230
walls, straight - FC1 115 IP1 100 - - 215
walls, round FB1 - 115 IP1 100 - - 215
2xGas duct III-II
walls, round FB1 - 115 IP1 100 - - 215
cone - FC1 115 IP1 100 - - 215
2xStage III / top section
roof - FC1 150 IP1 80 - - 230
spiral, straight FB1 - 115 IP1 100 - - 215
spiral, inclined - FC1 115 IP1 100 - - 215
walls, round FB1 - 115 IP1 100 - - 215
2xStage III / bottom section
cone FB1 - 115 IP1 100 - - 215
cone tip - FC1 115 IP1 100 - - 215
2xBend IV-III
roof - FC1 150 IP1 80 - - 230
walls, straight - FC1 115 IP1 100 - - 215
walls, round FB1 - 115 IP1 100 - - 215
2xGas duct IV-III
walls, round FB1 - 115 IP1 100 - - 215
cone - FC1 115 IP1 100 - - 215
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 10 of 26
Important note:
A guide value for the maximum shell temperature of the rotary kiln is 350°C.
The steel normally used for the kiln tube no longer features a defined stability at
temperatures above 350°C. However, as long as the kiln continues to revolve
temperatures up to 400°C do not yet mean an immediate risk.
Temperatures above 400°C mean a direct danger for the stability of the kiln tube.
The following qualities are recommended. Quality data see chapter 5.:
Split up of zones:
Important information:
• The maximum plate temperature of the kiln hood must not be more than 200°C.
Preconditions are an intact refractory lining and „normal operation“ of the plant.
Operating temperatures of the different components have been given under 2.2)
above.
• It should be emphasized at this juncture that for reasons of strength the rear
wall of the kiln hood has to be of concave shape, i.e. slightly vaulted towards
the plate shell. The brickwork shall then be bricked up stepwise towards the
cooler shaft in order not to create larger surfaces near the cooler connection
that will encourage the formation of dust deposits.
The following qualities are recommended. Quality data see chapter 5.:
wall system:
working 1st 2nd
component total
lining insulation insulation
main part type thickn. type thickn. type thickn. thickn. surface
2
bricks castable mm mm mm mm approx. m
head wall at kiln end
walls, straight - HC3 230 IB1 65 IP2 60 355 XX
arch section
arch roof HB3 - 230 IB1 65 IP2 60 355 XX
side walls
walls, straight HB3 - 230 IB1 65 IP2 60 355 XX
rear wall with door
walls, straight HB3 - 230 IB1 65 IP2 60 355 XX
connection to inlet duct
for dust chamber
roof - HC3 150 IB1 65 IP2 40 255 X
walls, straight / bottom HB3 - 115 IB1 65 IP2 60 240 XX
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 14 of 26
The refractory encasing consists of the wear layer made up of suitable castable and a
corresponding anchoring system.
The following qualities are recommended. Quality data see chapter 5.:
Encasing:
working lining thickness length
zone
type mm mm
3.5 Tertiary air duct: Diam. 2.710/3.100 x 98m long with slide gate:
Important information:
• The maximum plate temperature of the tertiary air duct must not be more than
140°C.
Preconditions are an intact refractory lining and „normal operation“ of the plant.
Operating temperatures of the different components have been given under 2.2)
above.
The following qualities are recommended. Quality data see chapter 5.:
wall system:
working 1st 2nd
component total
lining insulation insulation
main part type thickn. type thickn. type thickn. thickn.
bricks castable mm mm mm mm
tertiary air duct
walls, round FB2 - 100 IP2 40 IP1 60 200
connection to dust chamber
adapter element - FC3 100 IP2 40 IP1 60 200
connection to preheater
walls, round FB2 - 100 IP2 40 IP1 60 200
working
component volume
lining
main part type thickn.
3
bricks castable mm approx. m
slide gate
walls, straight - HC4 210 1.7
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 16 of 26
3.6 Dust settling chamber: Diam. 6.30/6.73m with inlet duct and dust return chute:
Important information:
• The maximum plate temperature of dust settling chamber, inflow channel and
dust return system must not exceed 140°C.
Preconditions are an intact refractory lining and „normal operation“ of the plant.
The operating temperatures of the different components have been given under
2.2) above.
Roof arrangement acc-214-011-100060-SH1
The following qualities are recommended. Quality data see chapter 5.:
wall system:
working 1st 2nd
component total
lining insulation insulation
main part type thickn. type thickn. type thickn. thickn.
bricks castable mm mm mm mm
dust chamber
roof - FC4 150 IP2 80 - - 230
walls, straight - FC4 115 IP2 40 IP1 60 215
walls, round FB3 - 115 IP2 40 IP1 60 215
cone FB3 - 115 IP2 40 IP1 60 215
cone tip - FC4 115 IP2 40 IP1 60 215
inlet duct
roof - FC4 150 IP2 80 - - 230
walls, straight FB3 - 115 IP2 40 IP1 60 215
bottom FB3 - 115 IP2 40 IP1 60 215
dust return chute
walls, round - HC2 80 - - - - 80
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 17 of 26
Important information:
• The maximum plate temperature of the Pyro floor cooler must not exceed 140°C.
Preconditions are an intact refractory lining and „normal operation“ of the plant.
The operating temperatures of the different components have been given under
2.2) above.
The following qualities are recommended. Quality data see chapter 5.:
wall system:
working 1st 2nd
component total
lining insulation insulation
main part type thickn. type thickn. type thickn. thickn.
bricks castable mm mm mm mm
inlet zone
head wall HB3 - 175 IP2 50 IP1 65 290
side walls HB3 - 175 IP2 50 IP1 65 290
horse shoe I - HC3 300 IB2 500 - - 800
horse shoe II - HC3 300 IB2 500 - - 800
bull nose HB3 -x 175 IP2 50 IP1 65 290
recuperative zone
roof HB3 - 180 IM1 75 - - 255
side walls HB3 - 175 IP2 50 IP1 65 290
recuperative wall/side walls - HC3 150 IC2 50 - - 200
below beam - HC3 180 IC2 50 - - 230
middle zone
roof FB2 - 180 IM1 75 - - 255
side walls, upper part FB2 - 175 IP2 75 - - 250
□side walls, lower part (clinker bed) - HC3 175 IP2 75 - - 250
waste air take off
roof, inclined - FC2 150 IP2 80 - - 230
side wall, inclined - FC2 115 IP2 60 - - 175
side wall, upper part FB2 - 175 IP2 75 - - 250
□side wall, lower part (clinker bed) - HC3 175 IP2 75 - - 250
partitions walls 1 and 2 - FC2 115 IP2 60 - - 175
outlet zone
roof FB2 - 180 IM1 75 - - 255
side walls, upper part FB2 - 175 IP2 75 - - 250
behind armouring - - - IC2 220 - - 220
end wall FB1 - 115 IP2 60 - - 175
2xgas duct III-II with bend 1.4301 304 X5 CrNi 18 10 1.4301 304 X5 CrNi 18 10
2xgas duct IV-III with bend 1.4301 304 X5 CrNi 18 10 1.4301 304 X5 CrNi 18 10
gas duct V-IV with bend 1.4301 304 X5 CrNi 18 10 1.4301 304 X5 CrNi 18 10
2xgas duct V-VI with bend 1.4301 304 X5 CrNi 18 10 1.4301 304 X5 CrNi 18 10
bend 90°/stage VI 1.4841 314 X15 CrNiSi 25 20 1.4845 310S X12 CrNi 25 21
connection to inlet duct for 1.4837 - GX 40 CrNiSi25-12 1.4845 310S X12 CrNi 25 21
dust chamber
dust chamber 1.4841 314 X15 CrNiSi 25 20 1.4845 310S X12 CrNi 25 21
inlet duct 1.4841 314 X15 CrNiSi 25 20 1.4845 310S X12 CrNi 25 21
waste air take off 1.4837 - GX 40 CrNiSi25-12 1.4845 310S X12 CrNi 25 21
BB1 BB2
basic brick basic brick
raw material basis magnesia spinel magnesia spinel
material resistent to resistent to
characteristics thermal shocks thermal shocks
characteristic
85-89% MgO 89-93% MgO
component
3 3
bulk density ~ 2.9 kg/dm ~ 2.9 kg/dm
2 2
cold chrushing strength ≥ 50 N/mm ≥ 50 N/mm
refractoriness under load,
> 1700 °C > 1700 °C
ta-value
apparent porosity ≤ 18 % ≤ 18 %
remarks chrome ore free chrome ore free
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 23 of 26
IB1 IB2
fire light brick fire light brick
light weight light weight
raw material basis
fireclay fireclay
characteristic
~38% Al2O3 ~35% Al2O3
component
3 3
bulk density ~ 0.5 kg/dm ~ 0.8 kg/dm
2 2
cold chrushing strength ≥ 1.5 N/mm ≥ 1.5 N/mm
classification
1260°C 1350°C
temperature
400°C ~ 0.16 W/mK ~ 0.36 W/mK
thermal
conductivity 800°C ~ 0.20 W/mK ~ 0.41 W/mK
1000°C ~ 0.25 W/mK ~ 0.47 W/mK
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011
page 25 of 26
IC1 IC2
insulating insulating
castable castable
raw material basis light weight light weight
fireclay fireclay
characteristic
~30% Al2O3 ~40% Al2O3
component
3 3
material required ~ 1.0 kg/dm ~ 2.1 kg/dm
cold chrushing 2 2
≥ 2.0 N/mm ≥ 30 N/mm
strength, 1000°C
max. temperature of
~ 1200 °C ~ 1200 °C
application
300°C ~ 0.25 W/mK ~ 0.40 W/mK
thermal
700°C ~ 0.25 W/mK ~ 0.40 W/mK
conductivity
1000°C ~ 0.30 W/mK ~ 0.50 W/mK
DCVL / India
P-02-0098.
Refractory Lining
Oct,2011