Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

1

Product catalogue

The global leader in


door opening solutions
2
Table of Contents
3

4 About us
5 Steel fire doors
24 Veneered steel door
28 Fire / security soundproof door
31 Fire cabinet
33 Aluminium fire door
40 Aluminium fixed fire wall
45 Bulletproof door
47 X-ray door
49 Smoke door
52 Soundproof door
54 Sliding fire door
59 Fire ventilation grilles
61 Automatic device for fire door
64 Passage control
71 Panic exit devices
74 Fittings
About us
4

METALIND - ASSA ABLOY


METALIND, as a part of ASSA ABLOY Group, is a leading manufacturer of steel fire resistant and non-
fire resistant steel doors, steel sliding gates, aluminium glazed doors and fixed glazed walls in Croatia.
Our products are customised and certified according to European standards, and are designed to
ensure people’s security, safety and convenience in residential and commercial buildings. METALIND
- ASSA ABLOY offers products that meet both safety and design requirements.

ASSA ABLOY Group


Who are we?
The ASSA ABLOY Group is the global leader in access solutions. Our offering covers products and
services related to openings, such as locks, doors, gates and entrance automation solutions. This
also includes expertise in controlling identities with keys, cards, tags, mobile and biometric identity
verification systems.

What do we do?
Every day, ASSA ABLOY helps billions of people experience a more open world through innovations
that enable safe, secure and convenient access to physical and digital places.

For whom?
We provide access solutions, trusted identities, entrance automation and service for institutional
and commercial customers, as well as for the residential market. The Group has the largest installed
base of products in the world with a large share of sales in the stable aftermarket.

Where are we?


The Group has leading positions in most of Europe, North and South America, Asia and Oceania.
5

Steel fire
doors
6
Steel fire doors / single-leaf
FERRO 62 fire

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Design: • glass pane, classes EI30, EI60, EI90


• solid, classes EI30, EI60, EI90 and EI120

Type designations: EI30 EI60 EI90 EI120


PV-1/30-S PV-1/60-S PV-1/90-S -
PV-1/30 PV-1/60 PV-1/90 PV-1/120

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

• without gasket (standard), only fire door

• with gasket – drop down seals or threshold, fire / smoke / soundproof

Fittings: • fire door lock EN 12209 (standard or panic function)


• 3D inox hinges
• fire door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: EI30 approx 40 kg/m2


EI60 approx 45 kg/m2
EI90 approx 60 kg/m2
EI120 approx 75 kg/m2

Door frame data plate: Serijski broj: Tip proizvoda:


ASSA ABLOY CROATIA d.o.o.,
00000 PV-1/30
Razredba otpornosti:
HRVATSKA
Odobreno tijelo: EI230
LTM d.o.o., HRVATSKA Godina: Razredbeni izvještaj:
2020. R-3776/13-1

Single-leaf steel fire doors may also be available in smokeproof


design – with EN 1634-3 certificate.
The doors are certified 7
by a certified institution
as a standard product
under an applicable
standard, complete
classification (according
to EN 1634-1)
8
Steel door glazing / single-leaf

TECHNICAL DATA:

Glazing flange: • profiled steel sheet 1,5 mm, plasticised finish in RAL colours

Flange Fittings: • visible screws on one side

Rubber gasket: • self-extinguishing, black

Dimensions: • dimension line 185 mm (for EI30 and EI60) is the minimum distance of glass from the leaf edge
(on the door face-hinge side) and 285 mm (for EI90)
• dimension line 300 is the minimum distance of glass from the floor

• the largest single glass pane: 1130 x 2450 mm

• any combination in between min and max surfaces is possible

Leaf glazing design:

Max 1130 mm Max 1130 mm Max 1130 mm


Max 1500 mm

Max 1500 mm
Max 2450 mm

Max 2450 mm
9
10
Steel fire doors / double-leaf
FERRO 62 fire

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door frame: sheet thickness 1,5 mm

Design: • glass pane, classes EI30, EI60, EI90


• solid, classes EI30, EI60, EI90 and EI120

Type designations: EI30 EI60 EI90 EI120


PV-2/30-S PV-2/60-S PV-2/90-S -
PV-2/30 PV-2/60 PV-2/90 PV-2/120

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

without gasket (standard), only fire door


with gasket – drop down seals or threshold, fire / smoke / soundproof

Fittings: • fire door lock EN 12209 (standard or panic function)


• 3D inox hinges
• fire door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: EI30 approx 40 kg/m2


EI60 approx 45 kg/m2
EI90 approx 60 kg/m2
EI120 approx 75 kg/m2

Door frame data plate:


Serijski broj: Tip proizvoda:
ASSA ABLOY CROATIA d.o.o.,
00000 PV-2/30
HRVATSKA Razredba otpornosti:
Odobreno tijelo: EI230
LTM d.o.o., HRVATSKA Godina: Razredbeni izvještaj:
2020. R-3849/14-1

Double-leaf steel fire doors may also be available in smokeproof


design – with EN 1634-3 certificate.
The doors are certified 11
by a certified institution
as a standard product
under an applicable
standard, complete
classification (according
to EN 1634-1)
12
Steel door glazing / double-leaf

TECHNICAL DATA:

Glazing flange: • profiled steel sheet 1,5 mm, plasticised finish in RAL colours

Flange fixing: • visible screws on one side

Rubber gasket: • self-extinguishing, black

Dimensions: • dimension line 185 mm (for EI30 and EI60) is the minimum distance of glass from the leaf edge
(on the door face-hinge side) and 285 mm (for EI90)
• dimension line 300 is the minimum distance of glass from the floor

• the largest single glass pane: 1130 x 2450 mm

• any combination in between min and max surfaces is possible

Leaf glazing design:

Max 1130 mm Max 1130 mm Max 1130 mm Max 1130 mm


Max 1500 mm
Max 2450 mm
1130 mm 1130 mm 1130 mm 1130 mm 13

Max 1500 mm
Max 2450 mm
14
Steel fire doors / single and double-leaf
FERRO flat 62 fire

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Design: • glass pane, classes EI30, EI60, EI90


• solid, classes EI30, EI60, EI90 and EI120

Type designations: EI30 EI60 EI90 EI120


PV-1/30-S PV-1/60-S PV-1/90-S -
PV-1/30 PV-1/60 PV-1/90 PV-1/120

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

• without gasket (standard), only fire door

• with gasket – drop down seals or threshold, fire / smoke / soundproof

Fittings: • fire door lock EN 12209 (standard or panic function)


• 3D inox hinges
• fire door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: EI30 approx 40 kg/m2


EI60 approx 45 kg/m2
EI90 approx 60 kg/m2
Horizontal cross EI120 approx 75 kg/m2

section:
Ag = rough opening (width)

A = clearance (width) Ag = rough opening (width)


Ag = rough opening (width)
A = clearance (width)
A = clearance (width)

Single-leaf steel fire doors may also be available in smokeproof


design – with EN 1634-3 certificate.
The doors are certified 15
by a certified institution
as a standard product
under an applicable
standard, complete
classification (according
to EN 1634-1)
16
Steel doors / single and double-leaf
FERRO 62/40

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Type designations: Single-leaf Double-leaf


IND/1-S IND/2-S
IND/1 IND/2

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber black
• in floor

without gasket (standard)


with gasket – drop down seals or threshold

Fittings: • door lock (standard or panic function)


• 3D inox hinges
• door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm and 40 mm

Leaf weight: • approx 40 kg/m2


17
18
Steel doors / single and double-leaf
KAKVARIUM 62

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Type designations: Single-leaf Double-leaf


K-IND/1-S K-IND/2-S
K-IND/1 K-IND/2

Finishing: • galvanised or
• plasticised in RAL colours or

Gaskets: • in door frame (three-sided)


rubber
• in floor

without gasket (standard)


with gasket – drop down seals or threshold

Fittings: • door lock (standard or panic function)


• 3D inox hinges
• door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: • approx 40 kg/m2

Horizontal cross
section:
Ag = rough opening (width)

55 AA==clearance (width)
prolazni otvor
Ag = rough opening (width)
Ag = rough opening (width)

55 A
A ==clearance
prolazni otvor
(width) 55
55 AA = prolazni
= clearance otvor
(width) 55
19
20
Steel fire doors / double-leaf
FERRO-M 62 fire

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door frame: sheet thickness 1,5 mm

Design: • glass pane, classes EI30, EI60, EI90


• solid, classes EI30, EI60, EI90

Type designations: EI30 EI60 EI90 EI120


PV-2/30-S-M PV-2/60-S-M PV-2/90-S-M -
PV-2/30-M PV-2/60-M PV-2/90-M PV-2/120

Finishing: • galvanised or
• plasticised in RAL colours or
• plasticised door frame

Gaskets: • in door frame (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

without gasket (standard), only fire door


with gasket – drop down seals or threshold, fire / smoke / soundproof

Fittings: • fire door lock EN 12209 (standard or panic function)


• 3D inox hinges
• fire door handle with round rosette (black PVC or stainless steel)

• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: EI30 approx 40 kg/m2


EI60 approx 45 kg/m2
EI90 approx 60 kg/m2
EI120 approx 75 kg/m2

Door frame data plate:

Serijski broj: Tip proizvoda:


ASSA ABLOY CROATIA d.o.o.,
00000 PV-2/30 -M
HRVATSKA Razredba otpornosti:
Odobreno tijelo: EI230
LTM d.o.o., HRVATSKA Godina: Razredbeni izvještaj:
2020. R-3849/14-1
The doors are certified 21
by a certified institution
as a standard product
under an applicable
standard, complete
classification (according
to EN 1634-1)

Ag = rough opening

55 A = clearance opening 55
22
Steel door details and
installation types

INSTALLATION
DETAILS:
Steel door details and 23

installation types

INSTALLATION
DETAILS:

INSTALLATION
TYPES:

DOOR SWING DIRECTION:

LEAF AND FLOOR JOINT - STEEL DOORS:


24

Veneered
steel door
Veneered steel door / 25

single-leaf and double-leaf

• For areas with demanding interior design, we propose improved fire doors with decorative lining

   (veneer, PVC lining ...) which will harmoniously blend with the interior.

• The structure is the same as for single-leaf/double-leaf steel fire door, with the addition of door leaf

    decorative lining, thickness 4mm. The selection of lining is on client’s demand (with natural
     veneer or PVC board with wood pattern or coloured).

• The installation of decorative lining on both or only on one side is possible.

CAN’T BE USED ON DOORS TYPE FERRO FLAT 62, KAKVARIUM 62

INSTALLATION joint Decor thickness 4 mm joint Decor thickness 4 mm


DETAILS: inox 3D inox 3D

Decor thickness 4 mm

Jamb, galvanised Jamb, galvanised

joint joint Decor thickness 4 mm


inox 3D inox 3D

Jamb, galvanised Jamb, galvanised

Decor thickness 4 mm joint


Decor thickness 4 mm Decor thickness 4 mm inox 3D

Decor thickness 4 mm
Decor thickness 4 mm

Jamb, galvanised
26
Veneered steel door /
single - leaf and double-leaf

WOODEN LINING-
DESIGNS:

INSTALLATION
55
DETAILS:
55
62

62

55

105
62

62
27
28

Fire / Security
soundproof door
Steel fire-security-soundproof door 29

CLASSIC EI30 - in RAL colours


DECORE EI30 - with veneered door-leaf

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm, steel structure reinforcement
on edges and diagonally
• door jamb: sheet thickness 2 mm

Type designations: EI30 EI60 EI90 EI120


Classic PPV30-C PV-1/60-S PV-1/90-S -
Decor PPV30-D PV-1/60 PV-1/90 PV-1/120

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

• with gasket – drop down seals or threshold, fire / smoke / soundproof

Fittings: • fire door lock ASSA ABLOY NEMEF EXCELLENCE LINE 3-POINT LOCK
• 3D inox hinges
• fire door handle or knob with round rosette (stainless steel)

• cylinder MAUER ELITE 2 (with 5 keys and the owner’s card)

• cylinder and handle rosette are round, separated

• additional cylinder mechanical protection by defender (stainless steel)

• peephole

• safety fixed pins in door leaf next to hinges, into the door jamb

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm or 70 mm

MAUER ELITE 2 Cylinder Peephole


Fire / Security - soundproof door
30

INSTALLATION 55
Ag = Rough opening
A = Clearance 55 50
Ag = Rough opening
A = Clearance 50 80
Ag = Rough opening
A = Clearance 80
DETAILS:
HALLWAY HALLWAY HALLWAY
31

Fire
cabinet
Fire cabinet
32

PPC

TECHNICAL DATA:

Construction:
- Cabinet door • galvanised steel sheet 0,8 mm
• EI60
• finishing: powder coating

• fire-rated glass EI60; dimensions 35 x 35 cm, thickness 25 mm

- Cabinet shell
(steel panel) • galvanised steel sheet 1,5 mm
• EI90
• finishing: powder coating

• no back side

• back side is a wall for mounting

(must be fire-rated)

Gaskets: • rubber and expanding gaskets in cabinet shell (all four sides)

Fittings: • fire-rated central lock (EN 12209)


• hinges with ball bearing (pcs.2)
• halfcylinder with 3 keys

• fire-rated expanding grills (pcs.2)

Installation: • on the brick or concrete wall


• dry assembly walls (with steel construction for mounting)
• installations for fire cabinet must be done concealed

• Dimensions according to the size of fire central

Most common dimensions 80 x 80 x 25 cm,


inside dimensions 65,8 x 65,8 x 18,5 cm.

Option: • ventilation fire-rated expanding grill

concrete wall

concrete wall Cabinet shell

Cabinet shell
33

Aluminium fire
door
34
Aluminium fire doors / single-leaf
ALU 80

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• fire insulation lining
• finish lining - standard aluminium profiles 70 and 104 mm

Design: • fire resistance classes EI30, EI60 and EI90

Type designations: EI30 EI60 EI90 EI120


PV-1/30-A PV-1/60-A PV-1/90-A -

Finishing: • plasticised in RAL colour

Gaskets: • in door jamb (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

without gasket (standard), or


with gasket – drop down seals or threshold

Fittings: • fire door lock EN 12209 (central)


• ball bearing joint (2 pcs)
• fire door handle with oval rosette EN 1906 – stainless steel

• rosette for cylinder and handle, oval, separated – stainless steel

• cylinder with three keys (standard or with wheel)

• hydraulic door closer for fire door EN 1154

Glazing: • glazing with fire resistant glass, classes EI30, EI60 and EI90
• maximum glass pane dimensions 1070 x 2370 mm

Installation: • on finished wall


• on unfinished wall – installation of door buck, wall finishing
before door installation

Door jamb data plate: Serijski broj: Tip proizvoda:


ASSA ABLOY CROATIA d.o.o.,
00000 PV-1/30-A
Razredba otpornosti:
HRVATSKA
Odobreno tijelo: EI230
LTM d.o.o., HRVATSKA Godina: Razredbeni izvještaj:
2020. R-3740/13-3
The doors are certified 35
by a certified institution
according to EN 1634-1
36
Aluminium fire doors / double-leaf
ALU 80

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• fire insulation lining
• finish lining – standard aluminium profiles 70 and 104 mm

Design: • fire resistance classes EI30, EI60 and EI90

Type designations: EI30 EI60 EI90 EI120


PV-2/30-A PV-2/60-A PV-2/90-A -

Finishing: • plasticised in RAL colour

Gaskets: • in door jamb (three-sided)


rubber – self-extinguishing, black
expanded, black
• in floor

without gasket (standard), or


with gasket – drop down seals or threshold

Fittings: • fire door lock EN 12209 (central)


• ball bearing joint (2 pcs)
• fire door handle with round rosette EN 1906 – stainless steel

• rosette for cylinder and handle, oval, separated – stainless steel

• cylinder with three keys (standard or with wheel)

• hydraulic door closer for fire door EN 1154

Glazing: • glazing with fire resistant glass, classes EI30, EI60 and EI90
• maximum glass pane dimensions 1070 x 2370 mm

Installation: • on finished wall


• on un-finished wall – installation of door buck, wall finishing
before door installation

Door jamb data plate: Serijski broj: Tip proizvoda:


ASSA ABLOY CROATIA d.o.o.,
00000 PV-2/30-A
HRVATSKA Razredba otpornosti:
Odobreno tijelo: EI230
LTM d.o.o., HRVATSKA Godina: Razredbeni izvještaj:
2020. R-3771/13-1
The doors are certified 37
by a certified institution
as a standard product
under an applicable
standard, complete
classification
(according
to EN 1634-1)
38
Aluminium door installation details
and types
Aluminium fire doors and walls are constructed with steel pipes lined with fire insulation
lining. Standard aluminium profiles, width 70 and 104 mm, are installed on insulation
lining, without screws.

INSTALLATION
DETAILS:

max 2370 mm
max 2370 mm

max 1070 mm
Aluminium door installation details 39

and types

Dimensions are valid for EI30 and EI60,


for EI90 dimension 80 increases to 95.
40

Aluminium fixed
fire wall
Aluminium fixed fire wall
41

ALU 80

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• fire insulation lining
• finish lining – standard aluminium profiles 104 mm

Design: • fire resistance classes EI30, EI60, EI90 and EI120

Type designations: EI30 EI60 EI90 EI120


PS-30-A PS-60-A PS-90-A PS-120-A

Finishing: • plasticised in RAL colour

Gaskets: • rubber – self-extinguishing, black


max 2370 mm
max 2370 mm

max 2370 mm

max 1070 mm
42

Maximum glass plane


1070 x 2370 mm
Aluminium fixed fire wall with
43

connected glass EI30, EI60

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• fire insulation lining
• finish lining – standard aluminium profiles 104 mm


FIRE-RATED SILICONE
Design: • fire resistance classes EI30, EI60
- Grinding glass edge for
installation in the mul-
Type designations: EI30 EI60 tiple side connecting
glass (frameless connec-
PS-30-C PS-60-C
tion, sealing with fire-ra-
ted silicone).

Finishing: • plasticised in RAL colour

Gaskets: • rubber – self-extinguishing, black


44
Horizontal systems EI60

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• fire insulation lining
• finish lining – standard aluminium profiles 104 mm

Design: • fire resistance classes EI60

Type designations: EI60


PS-60-H

Finishing: • plasticised in RAL colour

Gaskets: • rubber – self-extinguishing, black


45

Bulletproof
door
Bulletproof door
46

NV-1

TECHNICAL DATA:

Construction: • basic supporting structure made of steel pipes


• galvanised steel sheet metal lining, no finishing paint
• finish lining – standard aluminium profile 70 and 104 mm

• other parts, sheet thickness up to 4 mm

• internal reinforcements

Design: • ballistic resistance, class 3 (Magnum 357)

Type designations: • NV-1/KL-3

Finishing: • plasticised in RAL colours

Gaskets: • in door jamb (three-sided)


rubber, black

Fittings: • door lock DIN 18250 (central)


• ball bearing joint (2 pcs)
• fire door handle with round rosette – stainless steel

• rosette for cylinder and handle, oval, separated – stainless steel

• cylinder with three keys (standard or with wheel)

• hydraulic door closer for fire door EN 1154

• automatic door bolt in secondary leaf-top

Glazing: • armoured glass, ballistic resistance class BR3 (Magnum 357)


certified in compliance with EN 1063 standard
• panel, ballistic resistance class BR3

Installation: • on finished wall, vertical reinforced concrete tie beams


• threshold on the floor is necessary

Tested: • IGH - Zagreb


47

X-ray door
X - ray door
48

Type, composition, thickness, method of installation


and other characteristics of elements used for the
construction of a room in which x-ray machine,
accelerator or any other machine generating ionizing
radiation shall be foreseen and specified in the design,
taking into consideration the maximum energy and
strength of radiation, orientation of the beam and the
effective time of radiation generation.

TECHNICAL DATA:

Door type: • sliding


• pivot

Material: • galvanised steel sheet (leaf 1mm, door jamb 2mm)


plasticised in RAL colours
• stainless steel sheet

Barrier: • lead (panels or composed elements)


thickness according to the type of radiation up to 60 mm

Fittings: • special lock for x-ray door


• door jamb gasket – rubber (three-sided)
• ball bearing joint, only for the pivot door

• stainless steel handle

• leaf and floor joint according to the type of radiation

Installation: • door jamb and wall joint lined with lead

Additional equipment: • passage control


(determined by the • automatic opening/closing
client/design):
49

Smoke door
Smoke doors and walls
50

- aluminium

SMOKE DOOR -
ALUMINIUM:

Construction: • standard aluminium profile

Design: • single-leaf pivot, glass door


• double-leaf pivot, glass door

Type designations: • DN - 1 - A
• DN - 2 - A
• DN - FIX

Finishing: • plasticised in RAL colours

Gaskets: • in door jamb (three-sided)


rubber – self-extinguishing, black
expanded, black

• in floor with gasket drop down seals

Fittings: • lock, central


• joints, plasticised
• handle, of choice

• rosette for cylinder and handle oval, separated

• cylinder with three keys (standard or with wheel) (p. 44)

• hydraulic door closer for fire door EN 1154 (p. 44)

• door bolts in fixed leaf (only double-leaf door)

a) automatic, for doors with automatic device or panic fixings


b) folding for permanently closed secondary leaf

Glazing: • glass thickness 12 mm

The doors are certified


by a certified institution
A

as a standard product
under an applicable
standard, complete B B

classification (according
to HRN EN 13501-2)
A

B B
Smoke door - steel
51

TECHNICAL DATA:

Construction: • galvanised steel sheet


• door leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Type designations: Single-leaf Double-leaf


DN/1-S DN/2-S
DN/1 DN/2

Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame

Gaskets: • in door frame (three-sided)


rubber black
• in floor

with gasket – drop down seals

Fittings: • door lock (standard or panic function)


• 3D inox hinges
• door handle with round rosette (black PVC or stainless steel)

• cylinder with three keys (standard or with button)

• cylinder and handle rosette are round, separated

• hydraulic door closer with guide rail (standard RAL 9006)

Installation: • dry installation – door frame and wall joint with finish profile

Leaf thickness: • 62 mm

Leaf weight: • approx 40 kg/m2

Glazing: • glass thicnkess 12 mm


5-10
52

Soundproof door
Soundproof door
53

TECHNICAL DATA:

Construction: • galvanised steel sheet


• leaf: sheet thickness 0,8 mm
• door jamb: sheet thickness 1,5 mm

Design: • single-leaf
• double-leaf

Finishing: • galvanised or
• plasticised in RAL colours or
• leaf veneered, door jamb plasticized

Gaskets: • in door jamb (detail – bottom page drawing)


• in floor (detail – bottom page drawing)

Fittings: • lock (standard or panic design)
• 3D inox hinges
• handle for fire door with round rosette (standard PVC black or

stainless steel)
• cylinder with three keys (standard or with wheel)

• rosette for cylinder and handle round, separated

Installation: • door jamb and wall joint filled-in (by plastering)

Leaf thickness: • 62 mm

Leaf weight: • approx 60 kg/m²

It is possible to
manufacture single-leaf
steel fire pivot door
additionally as smoke
door – with HRN EN
1634-3 certificate
54

Sliding fire door


Sliding fire door
55

TECHNICAL DATA:

Construction: • galvanised steel sheet


• leaf: sheet thickness 0,8 - 1 mm
• other parts, sheet thickness 1,5 mm

Design: • single-leaf sliding door,class EI-90................................................ PV-1/90-K


• single-leaf sliding with pivot door,
class EI-90 ........................................................................................... PV-1/30-K-Z, PV-1/60-K-Z, PV-1/90-K-Z
• single-leaf sliding door, telescopic design,

class EI-90............................................................................................ PV-90-K-T


• double-leaf sliding door, class EI-90............................................ PV-2/90-K

• single-leaf sliding door, class EI-120............................................ PV-1/120-K

• double-leaf sliding door, class EI-120......................................... PV-2/120-K

Finishing: • galvanised or
• plasticised in RAL colours

Finishing and • weight for door closing (secures safe closing)


equipment • hydraulic brake regulates permanent leaf closing speed
(standard): up to 20 cm/s
• steel guide suspended on the wall above the opening

• guided cantilevers

• panel suspension – self-adjustable hinged sliding mechanism

with wheels
• bottom guide for door sliding (hidden under the leaf)

• automatic device for the open position of leaf and

release of the central station alarm signal or


manually by the control box push button
• electromagnet for keeping the leaf in the open position

Finishing and • electric motor for opening and closing


equipment • door leaf position detector (open, closed)
(additional): • optical smoke detector (when there is no central fire

station on the facility)


• light and sound signalling

• door locking

Installation: • on the finished wall


(reinforced by vertical and horizontal reinforced concrete wall)
• on the gypsum cardboard wall with steel construction

Door operation: • manual opening and closing


(opening and closing force up to 50 N)
• closed door shall be pushed to the maximum open position in

order to connect the weight to the electromagnet


• once the electromagnet is in contact with the weight, it is

possible to put the door leaf in any position (the door does not have
to be open to the maximum, this reduces draught and unfavourable working
conditions in the room protected by the door)
Sliding fire door
56

TECHNICAL DATA:

Door operation: • automatic closing is done by weight after the electromagnet


is released upon the activation of the automatic closing system or
by the control box push button
• sliding speed up to 20 cm/s, regulated by the hydraulic brake

The doors are certified by a certified institution as a standard product under an applicable standard,
complete classification (according to HRN EN 13501-2)
Sliding fire door - details
57

FIRERESISTANT SLIDING DOORS

Sliding door SCHEME & DETAILS FOR SLIDING DOORS :


standard drawing: Opti cal smoke detector (both sides - min 2 pcs )
C B
Elec tromagnet min 150 min 150

min 280

min 280
AB AB

Voltage 230 VAC P=6W (3x1,5mm ²)


Smoke detector (4x0,8 mm ²)
A

Fire alarm (2x0,8mm ²)

Structural height

Structural height
EA
AR

Passing height of the hinged door


I NG
ID
SL

~ 1800 mm
C B

Structural width
Cross section B-B Cross section C-C

AB AB

min 250 150


CLOSING OPENING Elec tromagnet
Control box
type : APV-2 Opti cal smoke detector

SCHEME & DETAILS FOR SLIDING TWO WING DOORS :

Optical smoke detector (bouth side - min 2 pcs )


C B
Elec tromagnet Ele c tromagnet min 150 min 150

Voltage 230 VAC P=6W (3x1,5mm ²)

min 280

min 280
AB AB

Smoke detector (4x0,8 mm ²)


Fire alarm (2x0,8mm ²)
A

Structural height

Structural height
EA

EA

Passing height of the hinged door


AR

AR
G

NG
IN

DI
ID

I
SL

SL

~ 1800 mm

C B

Cross section Cross section


B-B C-C
Structural width

AB AB

150 150
Elec tromagnet OPENING CLOSING CLOSING OPENING Elec tromagnet

Optical smoke detector

Sliding door
installation details:
Sliding fire door - details
58

Sliding telescopic
door drawing
and installation
details:

Steel construction
for sliding door:

Sliding door opening


orientation:
59

Fire ventilation grilles


60
Fire ventilation grilles

TECHNICAL DATA:

Construction: • fire ventilation grilles, class EI90


• fire ventilation dampers, class EI90

Design: • in wall (ventilation grille)


• in leaf (ventilation grille, damper)

Useful area: • grille up to 60 % net


• damper up to 80 % net

Installation: • galvanised steel sheet


• expanded materials
• meltable fuse

• protective net

Finishing: • galvanised, or
• plasticised in RAL colours

Thickness: • 125 mm in door leaf


61

Automatic device for


fire door
62
Automatic device for
fire pivot door

In areas with the high frequency of passage (hospitals, schools, hotels and similar), it is not
practical to open and close fire doors. We can offer equipment which keeps the door leaf (one or
both leaves) in the open position, the equipement enables undisturbed passage through doors, it is
used for automatic and proper closing when required by the user or fire alarm signal.

Keeping the fire door


175
in open position
and its automatic
closing complies with
applicable regulations.
For the automatic
closing system a
performance test
certificate is issued by
a certified company.

FD 460

Product description
ABLOY FD460 is a slim
and aesthetic fire door
closing system with sliding arm.
The door is held open by hold
open device in selected angle until the fire signal
switched off the control box APV-2
when smoke detectors react to smoke.

Overview of Advantages
• CE certifi ed according to EN1155
• Adjustable hold open angle 130°
• Adjustable hold open force
• Maximum door weight 120 kg and door width 1400 mm
• Installed with door closer that can be adjusted to force size EN 3-6
FD 462 63

Product description
ABLOY FD 462 is a slim and aestetic fire door closing system
with sliding arm. The door is hold open by hold devise in
selected angle until the power is switched off e.g. when the
control box APV-2 recive signal from fire central or form
smoke detectors.

Overview of Advantages
• CE certified according EN 1155 and EN 1158
• Adjusteble hol open angle 70°-130°
• Maximum door weight 120 kg per wing and dimenzion of
door wing in dimenzions 1250-2800mm

FUNCTION

Inactive door
With FD462 the normal day use is convenient
because both door leafs can be used independently.
Only the active door or both door leafs can be kept

Active door
open. The mechanical coordinator keeps the active
door open when inactive door is open. When the
power is switched off, i.e. when the smoke detectors
react to smoke, the inactive door closes first and when
it is almost closed, the active door starts to close. After
the active door is closed it latches the inactive door.
Hold open angle for both doors can be adjusted from
70 to 130 degrees. The Hold open devices include
adjustable hold open force. Current consumption 120
mA (24 VDC). FD120 must be used with closing
side installation of FD462.

1
4

1. Door cordinator FD462


2
2. APV2 control box
3. Manual switch APV2 control box
3
4. Optical smoke detector

Optical smoke detector


64

Passage control
Passage control 65

The equipment for fire door passage control it has to be installed in such a way that it does not
disturb the fire protection function of the door and, at the same time, to ensure the control of
entering and exiting through the door into and out of protected areas. Passage control is one-
sided and both-sided. On request, we also install reed contact for detection of leaf closing. Control
device (card reader, numeric keyboard) and electrical installation shall be provided by the client or
electrical installation contractor.

Passage control table:

1. Central electro lock EN12209


in door leaf, lock without contact
blocked (voltage on - free entrance)
U=12 VDC or 24 VDC, I=250 mA

4. Cable fuse

5. Reed contact

Entrance by the key or control device


Exit free

2. Electro strike (F class) in door jamb


opposite of central leaf lock, without
voltage electro strike is blocked
(voltage on - free entrance)
U=12 VDC or 24 VDC, I=250 mA

5. Reed contact

Entrance by the key or control device


Exit free

3. Electro strike (not F class) in door


jamb above door leaf, electro strike
is blocked under voltage
(voltage off - entrance / exit free)
U=12 VDC or 24 VDC, I=250 mA

5. Reed contact

Entrance/exit free by control device


In case of fire, for free entrance/exit,
connection on fire central must be
provided
66
1. Lock for passage control

The lock type ABLOY EL 560 is an electromagnetic lock and is used for passage control, and can be
installed on doors in the evacuation route according standards EN 179 and EN 1125. The lock is self-
locking. The lock operates at a voltage of 12 VDC to 24 VDC and is fire-rated. The lock must be in a
combination of handle / handle fittings on doors.

NOTE - in double doors, this lock is installed in wing A1, support wing with latch

Passage control table 1.

1. 2.

3.
1. Door lock ABLOY 560 – for steel door
2. lead cover EA280
3. cabel EA 218

1. 2.

3.

1. Door lock ABLOY 460 – for aluminium door


2. lead cover EA280
3. cabel EA 218
2. Electric strike 67

The electric strike type eff-eff 143 F is used on fire doors and is used for one side passage control.
The electric strike working on voltage 12VDC to 24VDC and is fire-rated. The electric strike is in
the normal mode of operation without voltage, while the arrival of voltage is the unblocking of the
electric strike. The electric strike goes in a combination knobe / handle Fittings: on doors.

NOTE - in double doors, this electric strike is installed in wing A2, main wing with standard
mehanical or panic lock.

Passage control table 2.


3. Electric strike
68

The electric strike type eff-eff 332 is used on doors in the evacuation route and is used for mutual
passage control, for which it is certified according to EN 13633 and EN 13637. Electric strike is
working on 12 or 24 VDC and is not fireproof. The electric strike is in the normal mode under
constant power, when power supply is break off the electric strike is unblocked and the passage
through the door is free. The electric strikes goes in a combination of handle / handle Fittings: on
doors.

Passage control table 3.

The electric strike type eff-eff 3705 is used for mutual passage control. Electric strike is working on
12 or 24 VDC and is not fireproof. The electric strike is in the normal mode under constant power,
when power supply is break off the electric strike is unblocked and the passage through the door is
free. The electric strikes goes in a combination of handle / handle Fittings: on doors.
Door lock ABLOY EL 420, EL 520
69

The lock type ABLOY EL 520 is electromotor lock and is used for passage control, and can be
installed on doors in the evacuation route according standards EN 179 and EN 1125. The lock is self-
locking. The lock operates at a voltage of 12 VDC to 24 VDC and is fire-rated. The lock must be in a
combination of konobe / handle Fittings: on doors.

NOTE - in double doors, this lock is installed in wing A1, support wing with latch

1. 2.

3.

4.

1. Door lock ABLOY 520 – for steel door


2. lead cover EA280
3. cabel EA 218
4. control box EA 420

1. 2. The lock type ABLOY EL 420 is electromotor lock and is used for passage control,
and can be installed on doors in the evacuation route according standards EN
179 and EN 1125. The lock is self-locking. The lock operates at a voltage of 12
VDC to 24 VDC and is fire-rated. The lock must be in a combination of konobe /
3. handle Fittings: on doors.

NOTE - in double doors, this lock is installed in wing A1, support wing with latch

4.

1. Door lock ABLOY 420 – for aluminium door


2. lead cover EA280
3. cabel EA 218
4. control box EA 420
70 The lock type ABLOY EL 520 is an electromotor lock and is used for passage control, and can be
installed on doors in the evacuation route according standards EN 179 and EN 1125. The lock is
self-locking. The lock operates at a voltage of 12 VDC to 24 VDC and is fire-rated. The lock must
be in a combination of konobe / handle Fittings: on doors. In combination with the PE 925 lock on
double-leafed swing doors to ensure passage control, the PE 925 lock can also be fitted to doors on
the evacuation route.
71

Panic exit devices


72 The basic function of the fire door is to prevent spreading of fire all over the building. Fire protection
studies, in addition to determining fire areas, also define evacuation exits. Any door, fire door also, in
the evacuation exit may be equipped with PANIC fittings.

The function of panic fittings is to prevent entrance through door on the locked side, and to allow
free exit at any time by activating panic mechanism. Fire door panic mechanism consists of panic
lock, automatic bolts (for double-leaf door, handle, knob or bar in compliance with EN 179 and EN
1125). It is important to point out that panic mechanisms are installed into the fire door structure.

1. Standard panic lock - main wing


4.
2. Standard panic lock - slave wing
3.
2.
1. 3. Panic push bar - main wing

4. Panic push bar - slave wing

PANIC LOCKS FOR SINGLE OR DOUBLE


WING DOOR - TYPE ASSAABLOY ONE SYSTEM
PANIC PUSH BAR - TYPE ASSAABLOY ONE SYSTEM INOX 73

PANIC LOCKS FOR SINGLE OR DOUBLE


WING DOOR - TYPE ASSAABLOY CORNY

PANIC PUSH BAR - TYPE ASSAABLOY CORNY PVC BLACK


74

Fittings
Fittings 75

HYDRAULIC DOOR For fire door in compliance with EN 1154


CLOSERS ASSA ABLOY:

Hydraulic closer with sliding guide – max opening angle 175° Hydraulic closer with bar

DOOR HANDLES:

PVC door handle Stainless steel door handle Stainless steel door handle
– on request

CYLINDER:

Standard cylinder Cylinder with wheel

DOOR HINGES:

Inox 3D adjustable door hinges Fixed door hinges for aluminium door
for steel doors
76ASSA ABLOY is the global leader
in door opening solutions,
dedicated to satisfying
end-users‘ needs for security,
safety and convenience

ASSA ABLOY CROATIA d.o.o.


43000 Bjelovar
Pakračka ulica 6, Croatia
Centrala: +385 (0) 43 242 434
Fax: +385 (0) 43 242 435
E-mail: prodaja@assaabloy.com
www.metalind.hr

You might also like