Professional Documents
Culture Documents
Katalog 2020 - Novi
Katalog 2020 - Novi
Product catalogue
4 About us
5 Steel fire doors
24 Veneered steel door
28 Fire / security soundproof door
31 Fire cabinet
33 Aluminium fire door
40 Aluminium fixed fire wall
45 Bulletproof door
47 X-ray door
49 Smoke door
52 Soundproof door
54 Sliding fire door
59 Fire ventilation grilles
61 Automatic device for fire door
64 Passage control
71 Panic exit devices
74 Fittings
About us
4
What do we do?
Every day, ASSA ABLOY helps billions of people experience a more open world through innovations
that enable safe, secure and convenient access to physical and digital places.
For whom?
We provide access solutions, trusted identities, entrance automation and service for institutional
and commercial customers, as well as for the residential market. The Group has the largest installed
base of products in the world with a large share of sales in the stable aftermarket.
Steel fire
doors
6
Steel fire doors / single-leaf
FERRO 62 fire
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
TECHNICAL DATA:
Glazing flange: • profiled steel sheet 1,5 mm, plasticised finish in RAL colours
Dimensions: • dimension line 185 mm (for EI30 and EI60) is the minimum distance of glass from the leaf edge
(on the door face-hinge side) and 285 mm (for EI90)
• dimension line 300 is the minimum distance of glass from the floor
Max 1500 mm
Max 2450 mm
Max 2450 mm
9
10
Steel fire doors / double-leaf
FERRO 62 fire
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
TECHNICAL DATA:
Glazing flange: • profiled steel sheet 1,5 mm, plasticised finish in RAL colours
Dimensions: • dimension line 185 mm (for EI30 and EI60) is the minimum distance of glass from the leaf edge
(on the door face-hinge side) and 285 mm (for EI90)
• dimension line 300 is the minimum distance of glass from the floor
Max 1500 mm
Max 2450 mm
14
Steel fire doors / single and double-leaf
FERRO flat 62 fire
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
Installation: • dry installation – door frame and wall joint with finish profile
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
Horizontal cross
section:
Ag = rough opening (width)
55 AA==clearance (width)
prolazni otvor
Ag = rough opening (width)
Ag = rough opening (width)
55 A
A ==clearance
prolazni otvor
(width) 55
55 AA = prolazni
= clearance otvor
(width) 55
19
20
Steel fire doors / double-leaf
FERRO-M 62 fire
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• plasticised door frame
• hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
Ag = rough opening
55 A = clearance opening 55
22
Steel door details and
installation types
INSTALLATION
DETAILS:
Steel door details and 23
installation types
INSTALLATION
DETAILS:
INSTALLATION
TYPES:
Veneered
steel door
Veneered steel door / 25
• For areas with demanding interior design, we propose improved fire doors with decorative lining
(veneer, PVC lining ...) which will harmoniously blend with the interior.
• The structure is the same as for single-leaf/double-leaf steel fire door, with the addition of door leaf
decorative lining, thickness 4mm. The selection of lining is on client’s demand (with natural
veneer or PVC board with wood pattern or coloured).
Decor thickness 4 mm
Decor thickness 4 mm
Decor thickness 4 mm
Jamb, galvanised
26
Veneered steel door /
single - leaf and double-leaf
WOODEN LINING-
DESIGNS:
INSTALLATION
55
DETAILS:
55
62
62
55
105
62
62
27
28
Fire / Security
soundproof door
Steel fire-security-soundproof door 29
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
Fittings: • fire door lock ASSA ABLOY NEMEF EXCELLENCE LINE 3-POINT LOCK
• 3D inox hinges
• fire door handle or knob with round rosette (stainless steel)
• peephole
• safety fixed pins in door leaf next to hinges, into the door jamb
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm or 70 mm
INSTALLATION 55
Ag = Rough opening
A = Clearance 55 50
Ag = Rough opening
A = Clearance 50 80
Ag = Rough opening
A = Clearance 80
DETAILS:
HALLWAY HALLWAY HALLWAY
31
Fire
cabinet
Fire cabinet
32
PPC
TECHNICAL DATA:
Construction:
- Cabinet door • galvanised steel sheet 0,8 mm
• EI60
• finishing: powder coating
- Cabinet shell
(steel panel) • galvanised steel sheet 1,5 mm
• EI90
• finishing: powder coating
• no back side
(must be fire-rated)
Gaskets: • rubber and expanding gaskets in cabinet shell (all four sides)
concrete wall
Cabinet shell
33
Aluminium fire
door
34
Aluminium fire doors / single-leaf
ALU 80
TECHNICAL DATA:
Glazing: • glazing with fire resistant glass, classes EI30, EI60 and EI90
• maximum glass pane dimensions 1070 x 2370 mm
TECHNICAL DATA:
Glazing: • glazing with fire resistant glass, classes EI30, EI60 and EI90
• maximum glass pane dimensions 1070 x 2370 mm
INSTALLATION
DETAILS:
max 2370 mm
max 2370 mm
max 1070 mm
Aluminium door installation details 39
and types
Aluminium fixed
fire wall
Aluminium fixed fire wall
41
ALU 80
TECHNICAL DATA:
max 2370 mm
max 1070 mm
42
TECHNICAL DATA:
FIRE-RATED SILICONE
Design: • fire resistance classes EI30, EI60
- Grinding glass edge for
installation in the mul-
Type designations: EI30 EI60 tiple side connecting
glass (frameless connec-
PS-30-C PS-60-C
tion, sealing with fire-ra-
ted silicone).
TECHNICAL DATA:
Bulletproof
door
Bulletproof door
46
NV-1
TECHNICAL DATA:
• internal reinforcements
X-ray door
X - ray door
48
TECHNICAL DATA:
Smoke door
Smoke doors and walls
50
- aluminium
SMOKE DOOR -
ALUMINIUM:
Type designations: • DN - 1 - A
• DN - 2 - A
• DN - FIX
as a standard product
under an applicable
standard, complete B B
classification (according
to HRN EN 13501-2)
A
B B
Smoke door - steel
51
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours or
• veneered door leaf, plasticised door frame
Installation: • dry installation – door frame and wall joint with finish profile
Leaf thickness: • 62 mm
Soundproof door
Soundproof door
53
TECHNICAL DATA:
Design: • single-leaf
• double-leaf
Finishing: • galvanised or
• plasticised in RAL colours or
• leaf veneered, door jamb plasticized
stainless steel)
• cylinder with three keys (standard or with wheel)
Leaf thickness: • 62 mm
It is possible to
manufacture single-leaf
steel fire pivot door
additionally as smoke
door – with HRN EN
1634-3 certificate
54
TECHNICAL DATA:
Finishing: • galvanised or
• plasticised in RAL colours
• guided cantilevers
with wheels
• bottom guide for door sliding (hidden under the leaf)
• door locking
possible to put the door leaf in any position (the door does not have
to be open to the maximum, this reduces draught and unfavourable working
conditions in the room protected by the door)
Sliding fire door
56
TECHNICAL DATA:
The doors are certified by a certified institution as a standard product under an applicable standard,
complete classification (according to HRN EN 13501-2)
Sliding fire door - details
57
min 280
min 280
AB AB
Structural height
Structural height
EA
AR
~ 1800 mm
C B
Structural width
Cross section B-B Cross section C-C
AB AB
min 280
min 280
AB AB
Structural height
Structural height
EA
EA
AR
G
NG
IN
DI
ID
I
SL
SL
~ 1800 mm
C B
AB AB
150 150
Elec tromagnet OPENING CLOSING CLOSING OPENING Elec tromagnet
Sliding door
installation details:
Sliding fire door - details
58
Sliding telescopic
door drawing
and installation
details:
Steel construction
for sliding door:
TECHNICAL DATA:
• protective net
Finishing: • galvanised, or
• plasticised in RAL colours
In areas with the high frequency of passage (hospitals, schools, hotels and similar), it is not
practical to open and close fire doors. We can offer equipment which keeps the door leaf (one or
both leaves) in the open position, the equipement enables undisturbed passage through doors, it is
used for automatic and proper closing when required by the user or fire alarm signal.
FD 460
Product description
ABLOY FD460 is a slim
and aesthetic fire door
closing system with sliding arm.
The door is held open by hold
open device in selected angle until the fire signal
switched off the control box APV-2
when smoke detectors react to smoke.
Overview of Advantages
• CE certifi ed according to EN1155
• Adjustable hold open angle 130°
• Adjustable hold open force
• Maximum door weight 120 kg and door width 1400 mm
• Installed with door closer that can be adjusted to force size EN 3-6
FD 462 63
Product description
ABLOY FD 462 is a slim and aestetic fire door closing system
with sliding arm. The door is hold open by hold devise in
selected angle until the power is switched off e.g. when the
control box APV-2 recive signal from fire central or form
smoke detectors.
Overview of Advantages
• CE certified according EN 1155 and EN 1158
• Adjusteble hol open angle 70°-130°
• Maximum door weight 120 kg per wing and dimenzion of
door wing in dimenzions 1250-2800mm
FUNCTION
Inactive door
With FD462 the normal day use is convenient
because both door leafs can be used independently.
Only the active door or both door leafs can be kept
Active door
open. The mechanical coordinator keeps the active
door open when inactive door is open. When the
power is switched off, i.e. when the smoke detectors
react to smoke, the inactive door closes first and when
it is almost closed, the active door starts to close. After
the active door is closed it latches the inactive door.
Hold open angle for both doors can be adjusted from
70 to 130 degrees. The Hold open devices include
adjustable hold open force. Current consumption 120
mA (24 VDC). FD120 must be used with closing
side installation of FD462.
1
4
Passage control
Passage control 65
The equipment for fire door passage control it has to be installed in such a way that it does not
disturb the fire protection function of the door and, at the same time, to ensure the control of
entering and exiting through the door into and out of protected areas. Passage control is one-
sided and both-sided. On request, we also install reed contact for detection of leaf closing. Control
device (card reader, numeric keyboard) and electrical installation shall be provided by the client or
electrical installation contractor.
4. Cable fuse
5. Reed contact
5. Reed contact
5. Reed contact
The lock type ABLOY EL 560 is an electromagnetic lock and is used for passage control, and can be
installed on doors in the evacuation route according standards EN 179 and EN 1125. The lock is self-
locking. The lock operates at a voltage of 12 VDC to 24 VDC and is fire-rated. The lock must be in a
combination of handle / handle fittings on doors.
NOTE - in double doors, this lock is installed in wing A1, support wing with latch
1. 2.
3.
1. Door lock ABLOY 560 – for steel door
2. lead cover EA280
3. cabel EA 218
1. 2.
3.
The electric strike type eff-eff 143 F is used on fire doors and is used for one side passage control.
The electric strike working on voltage 12VDC to 24VDC and is fire-rated. The electric strike is in
the normal mode of operation without voltage, while the arrival of voltage is the unblocking of the
electric strike. The electric strike goes in a combination knobe / handle Fittings: on doors.
NOTE - in double doors, this electric strike is installed in wing A2, main wing with standard
mehanical or panic lock.
The electric strike type eff-eff 332 is used on doors in the evacuation route and is used for mutual
passage control, for which it is certified according to EN 13633 and EN 13637. Electric strike is
working on 12 or 24 VDC and is not fireproof. The electric strike is in the normal mode under
constant power, when power supply is break off the electric strike is unblocked and the passage
through the door is free. The electric strikes goes in a combination of handle / handle Fittings: on
doors.
The electric strike type eff-eff 3705 is used for mutual passage control. Electric strike is working on
12 or 24 VDC and is not fireproof. The electric strike is in the normal mode under constant power,
when power supply is break off the electric strike is unblocked and the passage through the door is
free. The electric strikes goes in a combination of handle / handle Fittings: on doors.
Door lock ABLOY EL 420, EL 520
69
The lock type ABLOY EL 520 is electromotor lock and is used for passage control, and can be
installed on doors in the evacuation route according standards EN 179 and EN 1125. The lock is self-
locking. The lock operates at a voltage of 12 VDC to 24 VDC and is fire-rated. The lock must be in a
combination of konobe / handle Fittings: on doors.
NOTE - in double doors, this lock is installed in wing A1, support wing with latch
1. 2.
3.
4.
1. 2. The lock type ABLOY EL 420 is electromotor lock and is used for passage control,
and can be installed on doors in the evacuation route according standards EN
179 and EN 1125. The lock is self-locking. The lock operates at a voltage of 12
VDC to 24 VDC and is fire-rated. The lock must be in a combination of konobe /
3. handle Fittings: on doors.
NOTE - in double doors, this lock is installed in wing A1, support wing with latch
4.
The function of panic fittings is to prevent entrance through door on the locked side, and to allow
free exit at any time by activating panic mechanism. Fire door panic mechanism consists of panic
lock, automatic bolts (for double-leaf door, handle, knob or bar in compliance with EN 179 and EN
1125). It is important to point out that panic mechanisms are installed into the fire door structure.
Fittings
Fittings 75
Hydraulic closer with sliding guide – max opening angle 175° Hydraulic closer with bar
DOOR HANDLES:
PVC door handle Stainless steel door handle Stainless steel door handle
– on request
CYLINDER:
DOOR HINGES:
Inox 3D adjustable door hinges Fixed door hinges for aluminium door
for steel doors
76ASSA ABLOY is the global leader
in door opening solutions,
dedicated to satisfying
end-users‘ needs for security,
safety and convenience