Professional Documents
Culture Documents
1802 A 426-1 Toilet Elevation Type 07
1802 A 426-1 Toilet Elevation Type 07
25
Angle CONSTRUCTION ISSUE
FALSE CEILING FALSE CEILING
100
100 SIGNATURE:
Sealant KBF FOR ECCC
+2250 +2250
CFL 770 160 CFL 150
80
Wall Tile
100
400
400
6 Thk FC Board COPYRIGHT EAST COAST CONSTRUCTION COMPANY
TL 2 PTY. LTD.
SH Ledge Wall REPRODUCTION OF THE W HOLE OR PART OF THE
1050
DOCUMENT CONSTITUTES AND INFRINGES
1025
Wall Tile COPYRIGHT. THE INFORMATION, IDEAS AND
CONCEPTS CONTAINED IN THIS DOCUMENT ARE
900
900
6 Thk FC Board CONFIDENTIAL. THE RECIPIENT(S) OF THIS DOCUMENT
820 Nogging Track ARE PROHIBITED FROM DISCLOSING SUCH
INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
Stud Wall
600
600
WITHOUT PRIOR WRITTEN CONSENT OF THE
TL 2 COPYRIGHT HOLDER. ECCC HOLDS A LICENSE FROM
ARBT IN RESPECT OF PROPRITARY ITEMS
TL 2
LEDGE TOP 75x75 75x75 NOTE THIS DRAWING IS PREPARED BY EAST COAST
MX
SS TL 3 Flashing Angle Flashing Angle CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
50
FOR THE USE OF EAST COAST CONSTRUCTION
Starken Panel
150
150
594 160
2200
2250
2120
PROJECT
D-32
SUB- CONTRACTORS TO CHECK AND VERIFY ALL
1800
600
1800
1200
1200
1050
1050
1000
WC 75x75
HOB WALL 150 Flashing Angle
25
TO DETAIL
600
585
165
215
+50.0 SLOPE 1:80 SLOPE 1:100 +50.0
FFL FFL 6 Thk
FC Board
50
1200
ELEVATION - E1 ELEVATION - E2
1175
REFER DETAIL A REFER DETAIL A
Scale - 1 : 25 Scale - 1 : 25 Wall Tile Wall Tile
1163 350
108 291 2382 27 294 164 236 300 300 300 273 77 6 Thk FC Board
Stud Wall Nogging Track
FALSE CEILING FALSE CEILING A
REV
06-02-20
DATE DRN
JN BB
CHK
PRILIMINARY ISSUE
DESCRIPTION
100
100
75x75 25 75x75
Flashing Angle CLIENT:
+2250 +2250 Flashing Angle
50
CFL CFL
ASIA PACIFIC
400
400
400
400
Starken Panel
600
TL 2 EAST COAST CONSTRUCTION COMPANY PTY LTD
TL 2 Motor bed Main drainage flow E-mail: admin@ecccgroup.com.au
TL 2
Telephone: +61 (448)904475
Floor tiles Path of moisture
through grout and DETAIL AND DRAFTING:
2200
2200
mortar
FACADE 162 350
399 SS
1800
1800
600
600
1800
1800
TR
Grout
SS PH Waterproof
Drainage flange membrane Bradman Technologies Private Limited
31/22,Victoria Cresent Rd.Egmore,Chennai - 8,India
1200
1200
HOB WALL TEL: +91 44 42043347 Email: info@bradmanit.com
1000
TO DETAIL
TL 1 PROJECT:
TL 1
DETAIL - A (PADDLE FLANGE)
600
600
585
SET OUT HEIGHT TL 1 TL 2 SET OUT HEIGHT Scale - 1 : 10 54,CARL STREET,
BASED ON BASED ON TL 1 WOOLOONGABBA,QLD,AUSTRALIA
LONGEST VALLEY LONGEST VALLEY
165
215
215
+50.0 +50.0
FFL FFL DRAWING TITLE:
50
50
18-06-2020 11:36:24
ELEVATION - E3 ELEVATION - E4 MX MIXER TAP
CARL_FINISH LEGEND PH PAPER HOLDER DRAWN: CHECKED:
Scale - 1 : 25 Scale - 1 : 25 JN BB
CODE DESCRIPTION SH SHOWER HEAD
TL 1 150 X 150mm (FLOOR TILE) SS SHOWER SCREEN FIXING AT SITE FIRST ISSUE: SCALE:
NOTES:
TL 2 300 X 600mm (WALL TILE) TR TOWEL RAIL 06-02-20 As indicated @ A3
PROJECT NO DRAW ING NO REVISION
- Waterproofing as per AS 3740 TL 3 LEDGE WALL TOP FINISH (TO BE WC WATER CLOSET
CONFIRM) 1802 A 426-1 A