Wind Load - Low Rise Buildig (NSCP Section 207E)

Component Name Purlins


Figure:
L= 10.80 m Overhangs? (Y/N) Y
B= 14.60 m GCp Zone 1-3 Pos. = 0.42
Wind(x) θ° = 15.00 ° GCp Zone 1 Neg. = -0.86
Z= 6.50 m GCp Zone 2 Neg. = -2.20
B
hr= 20.00 m GCp Zone 3 Neg. = -3.21
h= 13.25 m a= 0.90 m

L Effective Area 2.40 m2


Effective Width 0.80 m
Plan Occupancy Category IV
Basic Wind Speed, V 250 kph
Exposure Category C
θo Enclosure Classification Enclosed Buildings

hr Stucture Type Components and Cladding


h
Z
Gust Effect Factor, G 0.85
Tophographic Factor, K zt 1.0
L ∝ 9.5
Elevation
zg 274.32
Kd 0.85
GCpi (+,-) 0.18
p=qh(GCp-Gcpi) (in kPa)
Roof Pressure
h kh or kz qz or qh p w/ +Gcpi p w/ -Gcpi
Wind Normal to Ridge
Zone 1 13.25 m 1.06 2.6686 kpa 1.595 kpa -2.772 kpa
Zone 2 13.25 m 1.06 2.669 kpa 1.595 kpa -6.351 kpa
Zone 3 13.25 m 1.06 2.669 kpa 1.595 kpa -9.034 kpa
Notes: (+) and (-) signs signify wind pressures acting toward & away from respective surfaces.
Wind Pressure @ Zone 1 1.276 kn/m -2.218 kn/m
Wind Pressure @ Zone 2 1.276 kn/m -5.081 kn/m
Wind Pressure @ Zone 3 1.276 kn/m -7.227 kn/m