MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Miniature Contactors AC+DC

Rated Current
Dimensions
380~440V
Coil Voltage
Type Frame Product Code
WxHxD KW AMP AMP 50/60Hz
(mm) AC3 AC1 AC3

AC24V D3783

AC48V D3784

AC110V D3785
GMC-6M 45x58x57 2.2KW 20A 6A
3-Pole 6A AC3 AC240V -
Auxiliary:
1NO or 1NC AC400V D3786
Ue: 690V AC550V -
Ui: 690V
Uimp: 6KV DC12V -

DC24V -
GMD-6M 45x58x69 2.2KW 20A 6A
DC48V -

DC110V -

AC24V D3792

AC48V D3793

AC110V D3794
GMC-9M 45x58x57 4KW 20A 9A
3-Pole 9A AC3 AC240V D3836
Auxiliary:
1NO or 1NC AC400V D6321
Ue: 690V AC550V D3795
Ui: 690V
Uimp: 6KV DC12V -

DC24V D3858
GMD-9M 45x58x69 4KW 20A 9A
DC48V -

DC110V -

AC24V D3807

AC48V D3805

AC110V D3809
GMC-12M 45x58x57 5.5KW 20A 12A
3-Pole 12A AC3 AC240V D2502
Auxiliary:
1NO or 1NC AC400V D3804
Ue: 690V AC550V D3806
Ui: 690V
Uimp: 6KV DC12V D3822

DC24V A2349
GMD-12M 45x58x69 5.5KW 20A 12A
DC48V -

DC110V -

AC24V D7499

AC48V D3816

AC110V D3817
GMC-16M 45x58x57 7.5KW 20A 16A
3-Pole 16A AC3 AC240V D2503
Auxiliary:
1NO or 1NC AC400V D3826
Ue: 690V AC550V D3818
Ui: 690V
Uimp: 6KV DC12V -

DC24V -
GMD-16M 45x58x69 7.5KW 20A 16A
DC48V -

DC110V -

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
102 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Miniature Thermal Overload

Rated Current
Applied To AC3 380~440VAC Product
Type Model
Product Code
Mid range In AMP Range In AMP
0.21A 0.16 - 0.25A D160

0.33A 0.25 - 0.4A D161

0.52A 0.4 - 0.63A D162

0.82A 0.63 - 1A D163

1.3A 1 - 1.6A D164


Class 10 Screw 2.1A 1.6 - 2.5A D165
Type
GMC-6 ~ 16M
Ue: 690V GTK-12M 3.3A 2.5 - 4A D166
GMD-6 ~ 16M
Ui: 680V
Uimp: 6KV 5.0A 4 - 6A D2774

6.5A 5 - 8A D167

7.5A 6 - 9A D2775

8.5A 7 - 10A D168

12A 9 - 13A D2777

14A 12 - 16A D2778

Miniature Contactors Accessories

Type Model Applied To Product Description Product Code


2NO D4287
AU-2M
1NO+1NC D3039
(top mount)
2NC D213

Auxiliary GMC-6 ~ 16M 4NO -


AU2/4: Top Mount GMD-6 ~ 16M 3NO+1NC D4302
AU-4M
2NO+2NC D204
(top mount)
1NO+3NC D4301
4NC -

1NO D4303

Auxiliary AU-1M GMC-6 ~ 16M


AU-1: Side Mount (side mount) GMD-6 ~ 16M

1NC D4304

ON-DELAY IN D2422
AC/DC 24-48V
OFF-DELAY IF D7749
Electronic Front
GMC-6 ~ 16M
Mount Timer AT-12M
GMD-6 ~ 16M
0.1-30 seconds
ON-DELAY 2N D1834

AC100-220V
OFF-DELAY 2F D7750

AC12 - 48V SURGE ABSORBER D4319

AC60 - 127V SURGE ABSORBER D4317

AC200-240V SURGE ABSORBER D4318


Surge GMC-6 ~ 16M
AS-12M DC12-24V SURGE ABSORBER D4322
Absorber Unit GMD-6 ~ 16M
DC30-72V SURGE ABSORBER D4320

DC100-127V SURGE ABSORBER D4323

DC200-250V SURGE ABSORBER D4321

GMC-6 ~ 16M
Interlock Device AR-12M MINI-CONTACTOR INTERLOCK UNIT D211
GMD-6 ~ 16M

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 103
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Screw Type Magnetic Contactors 3-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage
Type Frame Product Code
WxHxD KW AMP AMP 50/60Hz
(mm) AC3 AC1 AC3

AC24V D3351

AC48V D3352

AC110V D3353
MC-9B (AC) 45x73.5x86 4KW 25A 9A
AC240V D3354

Magnetic Contactor
AC415V D3355
22AF 3-Pole 9A AC3
Auxiliary: 1NO+1NC
Ue: 690V
AC550V D3356
Ui: 690V
Uimp: 6KV
DC12V D3357

DC24V D3358
MC-9B (DC) 45x73.5x117.7 4KW 25A 9A
DC48V D3359

DC110V D3360

AC24V D3361

AC48V D3362

AC110V D3363
MC-12B (AC) 45x73.5x86 5.5KW 25A 12A
AC240V D3364

Magnetic Contactor AC415V D3365


22AF 3-Pole 12A AC3
Auxiliary: 1NO+1NC
Ue: 690V AC550V D3366
Ui: 690V
Uimp: 6KV
DC12V D3367

DC24V D3368
MC-12B (DC) 45x73.5x117.7 5.5KW 25A 12A
DC48V D3369

DC110V D3370

AC24V D3371

AC48V D3372

AC110V D3373
MC-18B (AC) 45x73.5x86 7.5KW 32A 18A
AC240V D3374

Magnetic Contactor
22AF 3-Pole 18A AC3 AC415V D3375
Auxiliary: 1NO+1NC
Ue: 690V
Ui: 690V AC550V D3376
Uimp: 6KV

DC12V D3377

DC24V D3378
MC-18B (DC) 45x73.5x117.7 7.5KW 32A 18A
DC48V D3379

DC110V D3380

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
104 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Screw Type Magnetic Contactors 3-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage Product
Type Frame
WxHxD KW AMP AMP 50/60Hz Code
(mm) AC3 AC1 AC3

AC24V D3381

AC48V D3382

AC110V D3383
MC-22B (AC) 45x73.5x86 11KW 40A 22A
AC240V D3384

Magnetic Contactor
22AF 3-Pole 22A AC3 AC415V D3385
Auxiliary: 1NO+1NC
Ue: 690V
Ui: 690V AC550V D3386
Uimp: 6KV

DC12V D3387

DC24V D3388
MC-22B (DC) 45x73.5x117.7 11KW 40A 22A
DC48V D3389

DC110V D3390

AC24V D3391

AC48V D3392

AC110V D3393
MC-32A (AC) 69x83x93 15KW 50A 32A
AC240V D3394

Magnetic Contactor
40AF 3-Pole 32A AC3 AC415V D3395
Auxiliary: 2NO+2NC
Ue: 690V
Ui: 1000V AC550V D3396
Uimp: 8KV

DC12V D3397

DC24V D3398
MC-32A (DC) 69x83x120 15KW 50A 32A
DC48V D3399

DC110V D3400

AC24V D3401

AC48V D3402

AC110V D3403

MC-40A (AC) 69x83x93 18.5KW 60A 40A


AC240V D3404

Magnetic Contactor
AC415V D3405
40AF 3-Pole 40A AC3
Auxiliary: 1NO+1NC
Ue: 690V AC550V D3406
Ui: 1000V
Uimp: 8KV
DC12V D3407

DC24V D3408

MC-40A (DC) 69x83x120 18.5KW 60A 40A


DC48V D3409

DC110V D3410

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 105
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Screw Type Magnetic Contactors 3-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage Product
Type Frame
WxHxD KW AMP AMP 50/60Hz Code
(mm) AC3 AC1 AC3

AC24V D3411

AC48V D3412

AC110V D3413
MC-50A (AC) 79x106x129 22KW 70A 50A
Magnetic Contactor AC240V D3414
65AF 3-Pole AC3
Auxiliary: 1NO+1NC AC415V D3415
Ue: 690V AC550V D3416
Ui: 1000V
Uimp: 8KV DC12V D3417

DC24V D3418
MC-50A (DC) 79x106x149 22KW 70A 50A
DC48V D3419

DC110V D3420

AC24V D3421

AC48V D3422

AC110V D3423
MC-65A (AC) 79x106x129 30KW 100A 65A
Magnetic Contactor AC240V D3424
65AF 3-Pole AC3
Auxiliary: 2NO+2NC AC415V D3425
Ue: 690V AC550V D3426
Ui: 1000V
Uimp: 8KV DC12V D3427

DC24V D3428
MC-65A (DC) 79x106x149 30KW 100A 65A
DC48V D3429

DC110V D3430

AC24V D3431

AC48V D3432

AC110V D3433
MC-75A (AC) 94x140x137 37KW 110A 75A
AC240V D3434
Magnetic Contactor
100AF 3-Pole AC3
AC415V D3435
Auxiliary: 2NO+2NC
Ue: 690V
AC550V D3436
Ui: 1000V
Uimp: 8KV
DC12V D3437

DC24V D3438
MC-75A (DC) 94x140x174 37KW 110A 75A
DC48V D3439

DC110V D3440

AC24V D3441

AC48V D3442

AC110V D3443
MC-85A (AC) 94x140x137 45KW 135A 85A
AC240V D3444
Magnetic Contactor
100AF 3-Pole AC3
AC415V D3445
Auxiliary: 2NO+2NC
Ue: 690V
AC550V D3446
Ui: 1000V
Uimp: 8KV
DC12V D3447

DC24V D3448
MC-85A (DC) 94x140x174 45KW 135A 85A
DC48V D3449

DC110V D3450

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
106 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Lug Type Magnetic Contactors 3-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage Product
Type Frame WxHxD KW AMP AMP 50/60Hz Code
(mm) AC3 AC1 AC3

AC24V D3451
AC48V D3452
MC-100A AC110V D3453
Magnetic Contactor 94x140x137 55KW 160A 105A
(AC) AC240V D3454
100AF 3-Pole AC3
Auxiliary: 2NO+2NC AC415V D3455
Ue: 690V AC550V D3456
Ui: 1000V
Uimp: 8KV DC12V D3457
MC-100A DC24V D3458
94x140x174 55KW 150A 105A
(DC) DC48V D3459
DC110V D3460
AC24V D3461
AC48V D3462

Magnetic Contactor MC-130A AC110V D3463


95x158x132 60KW 180A 130A
150AF 3-Pole AC3 (AC) AC240V D3464
Auxiliary: 2NO+2NC
AC415V D3465
Ue: 690V
Ui: 1000V AC550V D3466
Uimp: 8KV DC24V D3467
MC-130A
95x158x132 60KW 180A 130A DC48V D3468
(DC)
DC110V D3469
AC24V D3470
AC48V D3471

Magnetic Contactor MC-150A AC110V D3472


95x158x132 75KW 200A 150A
150AF 3-Pole AC3 (AC) AC240V D3473
Auxiliary: 2NO+2NC
AC415V D3474
Ue: 690V
Ui: 1000V AC550V D3475
Uimp: 8KV DC24V D3476
MC-150A
95x158x132 75KW 200A 150A DC48V D3477
(DC)
DC110V D3478
AC/DC24V D3479
AC/DC48V D3480
MC-185A 90KW 250A 185A AC/DC100-220C D3481

Magnetic Contactor AC400V D3482


225AF 3-Pole AC3 AC500V D3483
Auxiliary: 2NO+2NC
138x203x181 AC/DC24V D3484
Ue: 690V
Ui: 1000V AC/DC48V D3485
Uimp: 8KV
MC-225A 132KW 300A 225A AC/DC100-220C D3486
AC400V D3487

AC500V D3488

AC/DC100-220C D3489
MC-265A 147KW 320A 265A AC400V D3490
AC500V D3491
AC/DC100-220C D3492
Magnetic Contactor AC400V D3493
MC-330A 160KW 350A 330A
400AF 3-Pole AC3
Auxiliary: 2NO+2NC AC500V D3494
163x243x196
Ue: 690V
Ui: 1000V AC/DC100-220C D3495
Uimp: 8KV
AC400V D3496
MC-400A 200KW 420A 400A

AC500V D3497

AC/DC100V D3498

Magnetic Contactor
500AF 3-Pole AC3 AC/DC200V D3499
Auxiliary: 2NO+2NC
MC-500A 285x312x242 265KW 550A 500A
Ue: 690V
Ui: 1000V
Uimp: 8KV AC400V D3500

AC500V D3501

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 107
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Lug Type Magnetic Contactors 3-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage
Type Frame Product Code
WxHxD KW AMP AMP 50/60Hz
(mm) AC3 AC1 AC3

AC/DC100V D3502

AC/DC200V D3503

AC400V D3504
Magnetic Contactor
630AF 3-Pole AC3
Auxiliary: 2NO+2NC MC-630A 285x312x242 330KW 660A 630A
Ue: 690V
Ui: 1000V
Uimp: 8KV
AC500V D3505

AC/DC100V D3506

AC/DC200V D3507

AC400V D3508
Magnetic Contactor
800AF 3-Pole AC3
Auxiliary: 2NO+2NC
MC-800A 285x312x242 440KW 900A 800A
Ue: 690V
Ui: 1000V
Uimp: 8KV
AC500V D3509

Screw Type Magnetic Contactors 4-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage Product
Type Frame
WxHxD KW AMP AMP 50/60Hz Code
(mm) AC3 AC1 AC3

AC24V D4234

AC48V D4235

Magnetic Contactor AC110V D4236


9AF 4-Pole AC3 MC-9A/4 (AC) 47.2x80.5x86.8 4KW 25A 9A
Ue: 690V AC240V D4231
Ui: 690V
Uimp: 6KV
AC415V D4237

AC550V D4238

AC24V D4112

AC48V D4113
Magnetic Contactor
12AF 4-Pole AC3 AC110V D4114
Ue: 690V MC-12A/4 (AC) 47.2x80.5x86.8 5.5KW 25A 12A
Ui: 690V AC240V D4111
Uimp: 6KV
AC415V D4115

AC550V D4116

AC24V D4136

AC48V D4137
Magnetic Contactor
18AF 4-Pole AC3 AC110V D4138
Ue: 690V MC-18A/4 (AC) 47.2x80.5x86.8 7.5KW 32A 18A
Ui: 690V AC240V D4141
Uimp: 6KV
AC415V D4139

AC550V D4140

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
108 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Screw Type Magnetic Contactors 4-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage
Type Frame Product Code
WxHxD KW AMP AMP 50/60Hz
(mm) AC3 AC1 AC3

AC24V D4156
AC48V D4157
Magnetic Contactor
22AF 4-Pole AC3 AC110V D4155
Ue: 690V MC-22A/4(AC) 47.2X80.5X86.8 11KW 40A 22A AC240V D4154
Ui: 690V
Uimp: 6KV AC415V D4159

AC550V D4160

AC24V D4176
AC48V D6225
Magnetic Contactor
32AF 4-Pole AC3 AC110V D7531
Ue: 690V MC-32A/4 (AC) 55X83.5X94.5 15KW 50A 32A AC240V D4174
Ui: 690V
Uimp: 6KV AC415V D4730

AC550V D4731

AC24V D6224
Magnetic Contactor AC48V D4732
40AF 4-Pole AC3
AC110V D6226
Ue: 690V
MC-40A/4 (AC) 55X83.5X94.5 18,5KW 60A 40A AC240V D3655
Ui: 690V
Uimp: 6KV AC415V D4733

AC550V D4734

AC24V D5002

AC48V D4735
Magnetic Contactor
50AF 4-Pole AC3 AC110V D6223
Ue: 690V MC-50A/4 (AC) 91X123.5X118 22KW 70A 50A
Ui: 690V AC240V D3656
Uimp: 6KV
AC415V D4729

AC550V D4736

AC24V D4757

AC48V D4737
Magnetic Contactor
65AF 4-Pole AC3 AC110V D4758
Ue: 690V MC-65A/4 (AC) 91X123.5X118 30KW 100A 65A
Ui: 690V AC240V D4759
Uimp: 6KV
AC415V D4738

AC550V D4739

AC24V D4677

AC48V D4740

Magnetic Contactor
AC110V D4678
75AF 4-Pole AC3
Ue: 690V MC-75A/4 (AC) 91X123.5X118 37KW 110A 75A
Ui: 690V
AC240V D4679
Uimp: 6KV

AC415V D4741

AC550V D4742

AC24V D4680

AC48V D4743
Magnetic Contactor
85AF 4-Pole AC3 AC110V D4681
Ue: 690V MC-85A/4 (AC) 91X123.5X118 45KW 135A 85A
Ui: 690V AC240V D4682
Uimp: 6KV
AC415V D4744

AC550V D4745

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 109
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Screw Type Magnetic Contractors 4-Pole

Rated Current
Dimensions
380~440VAC
Coil Voltage
Type Frame Product Code
WxHxD KW AMP AMP 50/60Hz
(mm) AC3 AC1 AC3

AC24V D3451

AC48V D4746
Magnetic Contactor
100AF 4-Pole AC3 AC110V D4107
Ue: 690V MC-100A/4 (AC) 170X203X185 55KW 160A 105A
Ui: 690V AC240V D4108
Uimp: 6KV
AC415V D4748

AC550V D4749

AC24V D4124

AC48V D4125

Magnetic Contactor AC110V D4126


130AF 4-Pole AC3
Ue: 690V MC-130A/4 (AC) 170X203X185 60KW 180A 130A
Ui: 690V
Uimp: 6KV AC240V D4127

AC400V D4128

AC500V D4129

AC24V D4130

AC48V D4131
Magnetic Contactor
150AF 4-Pole AC3 AC110V D4134
Ue: 690V MC-150A/4 (AC) 170X203X185 75KW 200A 150A
Ui: 690V AC240V D4135
Uimp: 6KV
AC415V D4132

AC550V D4133

AC/DC24V D4148

AC/DC48V D4149
Magnetic Contactor
185AF 4-Pole AC3
Ue: 690V MC-185A/4 170X203X185 90KW 250A 185A AC/DC100-220C D4150
Ui: 690V
Uimp: 6KV
AC400V D4152

AC500V D4153

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
110 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTOR ACCESSORIES
Contactor Accessories

Applied
Type Model Description Product Code
To Product

US-11 AC/DC 24~48V D4959

US-12 AC/DC 100~125V D4960


Surge Unit
Ui: 1000V MC-9B ~ MC-150A
Uimp: 8KV
IP20 US-13 AC/DC 200~240V D4961

US-14 AC 380~440V D4962

UR-02 MC-9B ~ MC-150A 2NC D4327

AR-180 MC-185A ~ MC-400A HORIZONTAL D210


Mechanical Interlock
Unit AR-600 HORIZONTAL D4968
MC-500A ~ MC-800A
AR-600 VERTICAL D4969

2NO D4963
UA-2 1NO+1NC D4756
2NC D3645
Auxiliary 4NO D3646
Contacts MC-9B ~ MC-150A FRONT MOUNT
3NO+1NC D3647
Ue: 600V
Ui: 600V UA-4 2NO+2NC D202
Uimp: 6KV 1NO+3NC D3648
Rated Current: 16A (UA-1: 10A)
4NC D3649
UA-1 1NO+1NC D200
MC-185A ~ MC-800A SIDE MOUNT
AU-100E 1NO+1NC D4687

AC-9 MC-9B ~ MC-40A 560-2160A D3529

Capacitor Discharge Unit


(Pre-Loading Resistor)
3-Pole N/O
AC-50 MC-50A ~ MC-100A 2160-3040A D3530

UT1F OFF-DELAY D3740


AC/DC24-48V
UT1N ON-DELAY D3741
Electronic Front Mount Timer
MC-9A ~ MC-150A
0.1-30 seconds
UT2F OFF-DELAY D3742
AC110-220V
UT2N ON-DELAY D3743

MC-9A ~ MC-85A D3781

Safety Cover AP-9 SAFETY COVER

MC-185A ~ MC-800A D3780

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 111
MOTOR CONTROL AND ACCESSORIES

CONTACTOR ACCESSORIES
Coils for 3-Pole Contactors

Applied
Type Model Voltage Product Code
To product

AC24V D4930

AC48V D4931

AC110V D4932

AC240V D4933

AC415V D4934

MC-32A
Replacement Coils AC550V 50/60Hz D4935
MC40A
MC-32A ~ MC-40A
DC12V -

DC24V -

DC48V -

DC110V -

DC250V -

AC24V D3748

AC48V D3749

AC110V D3750

AC240V D3751

AC415V D3752

MC-50A
Replacement Coils AC550V 50/60Hz D3753
MC65A
MC-50A ~ MC-65A
DC12V -

DC24V -

DC48V -

DC110V -

DC250V -

AC24V D4936

AC48V D4937

AC110V D4938

AC240V D4939

AC415V D4940

MC-75A
Replacement Coils AC550V 50/60Hz D4941
MC100A
MC-75A ~ MC-100A
DC12V -

DC24V -

DC48V -

DC110V -

DC250V -

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
112 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTOR ACCESSORIES
Coils for 3-Pole Contractors

Apply To
Type Model Voltage Product Code
Product

AC24V D4943

AC48V D4944

AC110V D4945
MC-130A
Replacement Coils
MC-150A
MC-130A ~ MC-150A
AC220V D4946

AC400V D4947
50/60Hz
AC500V D4948

DC24V -

DC48V -
Replacement Coils MC-130A
MC-130A ~ MC-150A MC-150A
DC110V -

DC220V -

AC/DC24V D4949

AC/DC48V D4950

Replacement Coils MC-185A


AC/DC100~240V COMMON COIL D4951
MC-185A ~ MC-225A MC-225A

AC400V D4952

AC500V D4953

AC/DC100~240V D4954

Replacement Coils MC-265A


AC400V COMMON COIL D4955
MC-265A ~ MC-400A MC-400A

AC500V -

AC/DC110V D4956

AC/DC240V D4957

Replacement Coils MC-500A


COMMON COIL
MC-500A ~ MC-800A MC-800A

AC400V D4958

AC500V D5080

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 113
MOTOR CONTROL AND ACCESSORIES

THERMAL OVERLOAD UNITS


Thermal Overload Relays

Rated Current AC3


Dimensions Product Code
380~440VAC
Applied To
Type Frame
WxHxD Product Mid Range Range Class Class
(mm) In AMP In AMP 10 20

0.14A 0.1 - 0.16A D3510 -

0.21A 0.16 - 0.25A D3511 -

0.33A 0.25 - 0.4A D3512 -

0.52A 0.4 - 0.63A D3513 -

0.82A 0.63 - 1A D3514 -

1.3A 1 - 1.6A D3515 -

2.1A 1.6 - 2.5A D3516 -

3.3A 2.5 - 4A D3517 -

5A 4 - 6A D3518 -
MC-9B TO
MT-32 (3K) 45x75x90
MC-40A
6.5A 5 - 8A D3519 -

7.5A 6 - 9A D3520 -

8.5A 7 - 10A D3521 -

11A 9 - 13A D3522 -

15A 12 - 18A D3523 -

19A 16A- 22A D3524 -


Thermal
Overload
21.5A 16A-22A D4697 -
Screw Type
Ue: 690V
27A 18-25A D4698 -
Ui: 680V
Uimp: 6KV
34A 22-32A D4699 -

1.3A 1 - 1.6A - D4750

2.1A 1.6 - 2.5A - D4688

3.3A 2.5 - 4A - D4689

5A 4 - 6A - D4690

6.5A 5 - 8A - D4691

7.5A 6 - 9A - D4692
MC-9B TO
MT-32 (3D) 45x75x90 8.5A 7 - 10A - D4693
MC-40A
11A 9 - 13A - D4694

15A 12 - 18A - D4695

19A 16A- 22A - D4696

21.5A 18 - 25A - D4697

27A 22 - 32A - D4698

34A 28 - 40A - D4699

42A 34 - 50A D4700 -

MT-63 (3K)
Thermal 54A 45 - 65A D4701 -
Overload
MC-50A TO
Ue: 690V 55x81x100
MC-65A
Ui: 680V
Uimp: 6KV 42A 34 - 50A - D4702

MT-63 (3D)
54A 45 - 65A - D4703

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
114 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

THERMAL OVERLOAD UNITS


Thermal Overload Relays

Rated Current AC3


Dimensions
380~440VAC
Applied To Product
Type Frame
WxHxD Product Mid Range Range Code
(mm) In AMP In AMP

65A 54 - 75A D4708

74A 63 - 85A D4709


MT-95 (3K)
CLASS 10
83A 70 - 95A D4710
Thermal
Overload 90A 80 - 100A D4711
MC-75A TO
Ue: 690V 70x97x110
MC-100A
Ui: 680V 65A 54 - 75A D4704
Uimp: 6KV
74A 63 - 85A D4705
MT-95 (3D)
CLASS 20
83A 70 - 95A D4706

90A 80 - 100A D4707

93A 80 - 105A D4712


MT-150 (3K)
113A 95 - 130A D4713
Thermal CLASS 10
Overload
130A 110 - 150A D4714
Lug Type MC-130A TO
95x109x113
Ue: 690V MC-150A
93A 80 - 105A D4715
Ui: 680V
Uimp: 6KV MT-150 (3D)
113A 95 - 130A D4716
CLASS 20
130A 110 - 150A D4717

153A 120 - 180A D4718


MT-225 (3K)
Thermal CLASS 10
200A 160 - 240A D4719
Overload
MC-185A TO
Ue: 690V 147x141x184
MC-225A
Ui: 680V
153A 120 - 180A D4720
Uimp: 6KV MT-225 (3D)
CLASS 20
200A 160 - 240A D4721

265A 200 - 330A D4722


MT-400 (3K)
CLASS 10

Thermal 350A 260 - 400A D4723


Overload
MC-265 TO
Ue: 690V 151x171x198
MC-400
Ui: 680V
Uimp: 6KV 265A 200 - 330A D4724

MT-400 (3D)
CLASS 20
350A 260 - 400A D4725

515A 400 - 630A -

MT-800 (3K)
CLASS 10

Thermal 660A 520 - 800A -


Overload
MC-500 TO
Ue: 690V 360x530x212
MC-800
Ui: 680V
Uimp: 6KV 515A 400 - 630A D4726

MT-800 (3D)
CLASS 20

660A 420 - 800A D4727

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 115
MOTOR CONTROL AND ACCESSORIES

THERMAL AND ELECTRONIC OVERLOAD UNITS


Thermal Overload Accessories

Applied
Type Model Description Product Code
To Product

UZ-32 MT-32 SEPARATE MOUNTING UNIT D6231

UZ-63/S MT-63 SEPARATE MOUNTING UNIT D6252


Adaptor

UZ-95/S MT-95 SEPARATE MOUNTING UNIT D3727

UZ-150/S MT-150 SEPARATE MOUNTING UNIT D4974

UM-4R 400mm CABLE D4326

Remote Reset UM-5R MT-32 ~ MT-95 500mm CABLE -

UM-6R 600mm CABLE -

Electronic Motor Protection Relay

Dimensions Rated Current


Adjustment Product
Type Frame WxHxD AMP Range Code
(mm) AC3

0.15 - 0.75KW 1.5A 0.3 - 1.5A D7269

GMP22-3SR 0.35 - 2.2KW 5A 1 - 5A D7270

53x87.5x68 2.2 - 11KW 22A 4.4 - 22A D7271


Electronic
Motor Protection Relay
Separate Mount Unit 1.8 - 10KW 20A 4 - 20A D7274
3x CT and direct
GMP40-3SR
100-260V Control
Protection: 4 - 18.5KW 40A 8 - 40A D7275
• Overcurrent/Stall
• Phase Failure/Reverse
GMP80-3SR 89x97x77.5 7.5 - 37KW 80A 16-80A D4066

GMP60-T
0-30KW 60A 0.5-60A -
110V
72x63x69
GMP60-T
60A 0.5-60A -
220V

DMP-06S 0.22 - 3KW 6A 0.5 - 6A D4055

D4056 (110V)
DMP-60S 0.22 - 30KW 60A 5 - 60A
Digital Motor D4058 (220V)
Protection Relay 78x109x97
(SZ = With Ground Fault)
DMP-06SZ 0.22 - 3KW 6A 0.5 - 6A D4059

D4061 (110V)
DMP-60SZ 0.22 - 30KW 60A 5 - 60A
D4060 (220V)

1.5MTR -

1MTR -
DMP Extension
EXTENSION CABLE FOR DIGITAL MOTOR PROTECTION RELAY (DMP)
Cable
2MTR D7853

4MTR -

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
116 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Manual Motor Starters

Dimension Rated Current


Adjustment
Type Model WxHxD Product Code
KW AC3 Amp AC3 Range In AMP
(mm)
0.18KW 0.4A 0.25 ~ 0.4A D3200
0.2KW 0.63A 0.4 ~ 0.63A D3201
0.3KW 1A 0.63 ~ 1A D1
0.55KW 1.6A 1 ~ 1.6A D2
0.75KW 2.5A 1.6 ~ 2.5A D3
Manual Motor
Starter 3-Pole (32AF) 1.5KW 4A 2.5 ~ 4A D4
100% Ics; Icu 2.2KW 6A 4 ~ 6A D5
25kA @ 400/415V MMS-32H 45x94x85.3
• Overload Protection 3KW 8A 5 ~ 8A D6
• Phase Fail Protection 4KW 10A 6 ~ 10A D7
• Short Circuit Protection
5.5KW 13A 9 ~ 13A D8
7.5KW 17A 11 ~ 17A D9
10KW 22A 14 ~ 22A D10
11KW 26A 18 ~ 26A D11
15KW 32A 22 ~ 32A D12

18.5KW 40A 28 ~ 40A D14

Manual Motor
Starter 3-Pole (63AF)
100% Ics; Icu
100kA @ 400/415V MMS-63S 55x140x130.3 22KW 50A 34 ~ 50A D7666
• Overload Protection
• Phase Fail Protection
• Short Circuit Protection

30KW 63A 45 ~ 63A D3215

Manual Motor Starter Accessories

Type Model Fit To MMS Description Product Code

MEH-32 MMS-32 D4561

Extended
Rotary MEH-63 MMS-63 Lockable Handle With 315mm Shaft D4562
Handle

MEH-100 MMS-100 D4563

1NO+1NC D206

FX FRONT MOUNTED 2NO D5003


Auxiliary 2NC D7746
MMS-32 ~ 100
Contacts
2-Pole 1NO+1NC D207

LX SIDE MOUNTED ON LEFT 2NO D7747


2NC D7748

1NO+1NC D4272

Magnetic Trip LAM SIDE MOUNTED ON LEFT 2NO D4271

2NC D4273

1NO+1NC D4269
Any Trip Alarm
Switch LA SIDE MOUNTED ON LEFT 2NO D4268
2-Pole
2NC D4270

AC24V D4068
MMS-32 ~ 100
AC110-127V D4069
Shunt Trip AC220-230V D173
(Cannot be used in RS SIDE MOUNTED ON RIGHT
combination with RU or RUX) AC240V D4070
AC380-400V D4071
AC415-440V D4072
AC24V D14576
AC110-127V D14577
Under Voltage Trip
(Cannot be used in RU SIDE MOUNTED ON RIGHT AC240V D2976
combination with RSor RUX)
AC380-400V D2697

AC415-440V D4275

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 117
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Manual Motor Starter Accessories

Type Model Fit To MMS Description Product Code


AC24V D4276
AC110-127V D4277
Under Voltage Trip AC220-230V E85
(Cannot be used in MMS-32 ~ 100
RUX SIDE MOUNTED ON RIGHT AC240V D4278
combination with RSor RU)
AC380-400V D4279

AC415-440V D4280

PB322 2x TERMINALS D212


MMS-32H 63A RATED
PB323 3x TERMINALS D4281
Phase Busbar
PB632 2x TERMINALS D4284
MMS-63S 108A RATED
PB633 3x TERMINALS D4977

IP65
EPH-32 MMS-32H ENCLOSURE SURFACE MOUNT IP65 D2690
Enclosure

DA-16HA DIRECT MOUNT WITH (AC) GMC-6M - 16M D4286


DA-16HD DIRECT MOUNT WITH (DC) GMD-6M - 16M D14578
MMS-32H
DA-32HA DIRECT MOUNT WITH (AC) MC-9 - 32 D4298
Direct
Adaptor DA-32HD DIRECT MOUNT WITH (DC) MC-9 - 32 (DC) D14579
Contactor to Manual DA-63A DIRECT MOUNT WITH (AC) MC-35 - 63 D4299
Motor Starter Adapter MMS-63
DA-63D DIRECT MOUNT WITH (DC) MC-35 - 63 (DC) D14580
DA-95A DIRECT MOUNT WITH (AC) MC-35 - 63 D4300
MMS-100
DA-95D DIRECT MOUNT WITH (DC) MC-35 - 63 (DC) D14581
Lug Type Contactors To Be Used With The Above Adaptors
MU-45 MMS-32H 45MM MOUNTING UNIT FOR MMS D4288
Mounting Unit MU-55 MMS-63 55MM MOUNTING UNIT FOR MMS D4289
MU-70 MMS-100 70MM MOUNTING UNIT FOR MMS D4290

DIRECT ONLINE STARTERS


Magnetic Direct Online Starters (No Overload)

AC1 AC3 KW Product


Type Model Coil Voltage
RATING RATING RATING Code
GMW-9 25A 9A 220V 4KW D4994
GMW-12 25A 12A 220V 12KW D4996
GMW-18 40A 18A 220V 18KW D4998
GMW-22 40A 22A 220V 22KW D5000
GMW - DOL Starters GMW-9 25A 9A 415V 4KW D4995
GMW-12 25A 12A 415V 12KW D4997
GMW-18 40A 18A 415V 18KW D4999
GMW-22 40A 22A 415V 22KW D5001

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
118 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

STAR DELTA STARTERS

Type KW Rating Overload Range Enclosure Product Code


Enclosed Star Delta
11kW 12-18A 300x300x200 D7245
15kW 16-22A 400x300x200 D7246
18,5kW 18-26A 400x300x200 D7247
22kW 24-36A 400x300x200 D7248
30kW 28-40A 500x400x200 D7249
37kW 34-50 600x400x250 D14582

55kW 54-75 600x400x250 D13947

Enclosed Star Delta with Isolator


11kW 12-18A 300x300x200 D7251
15kW 16-22A 400x300x200 D7252
18,5kW 18-26A 400x300x200 D7253
22kW 24-36A 400x300x200 D7254
30kW 28-40A 600x400x250 D7255
37kW 34-50 600x400x250 D14583

55kW 54-75 600x400x250 D13947

Enclosed Star Delta with Isolator and Amp Meter


11kW 12-18A 300x300x200 D7843
15kW 16-22A 400x300x200 D7844
18,5kW 18-26A 400x300x200 D7845
22kW 24-36A 400x300x200 D7846
30kW 28-40A 600x400x250 D7847
37kW 34-50 600x400x250 D7849

55kW 54-75 600x400x250 D14584

Type KW Rating @400 Overload Range Product Code


Open Star Delta

11kW 12-18A D7257

15kW 16-22A D7258

18,5kW 18-26A D7259

22kW 24-36A D7260

Extra’s
• Phase Failure
• Ammeter and CT
• 24Hr Timer
• Selector Switch
• Pressure Switch
• Indicator Lamp
• Selector Switches

Note:
• Star Delta Starters and direct online units can be built to customers’ specifications.

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 119
MOTOR CONTROL AND ACCESSORIES

MISCELLANEOUS
Pushbutton and Pilot Light Series

Type Description Product Code


1N/O WHITE D1427

1N/O BLACK D1428

22mm Flush 1N/O GREEN D1429


22mm Pushbutton Pushbutton c/w Fixing
Collar and Contact Block 1N/C RED D1431

1N/O YELLOW D1434

1N/O BLUE D1435

1N/O 2 Pos Stay Put Selector D1437

22mm Selector Switch 2N/O 3 Pos Stay Put Selector D1438


22mm Selector Switch and Key Switch c/w
and Key Switch Fixing Collar and Contact
1N/O 2 Pos Stay Put Key Switch D1442
Block

2N/O 3 Pos Stay Put Key Switch D1443

22mm Stop/Start c/w


22mm Stop/Start Com-
Fixing Collar and Contact 1N/O+1N/C GREEN/RED D1454
bination
Block

Emergency Stop Twist to


D1457
Release
22mm Emergency Stop Emergency Stop Push-Pull D1458
1N/C RED
Buttons
Emergency Stop Key
D1455
Release

24V D14585
110V D14587
WHITE
240V D999
380V D1459
24V D4504
110V D14588
RED
240V D998
380V D1461
24V D4504
22mm LED Pilot Light 110V D14589
22mm LED Pilot Light GREEN
Complete Unit 240V D997
380V D1460
24V D4506
110V D14590
YELLOW
240V D1000
380V D1462
24V D14586
110V D1239
BLUE
240V D996
380V D1462

Pushbutton And Pilot Light Accessories

Type Description Product Code


N/O Contact Block 1N/O D1473
Spare Contact Block N/C Contact Block 1N/C D1474
And Fixing Collar
Fixing Collar D1472

1 Hole Yellow
65X65mm L901
Empty Enclosure

1 Hole Grey
65X65mm L900
Empty Enclosure
Empty Enclosures
2 Hole Grey
100x65mm L902
Empty Enclosure

3 Hole Grey
135x65mm L903
Empty Enclosure

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
120 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
TeSys D-Range Contactors

TeSys D contactors for motor control up to 75kW at 400V, in category AC-3.


For connection by screw clamp terminals and lugs selection.

LC1 D09** LC1 D25** LC1 D65A** LC1 D95A** LC1 D115A** LC1D150**

3-Pole Contactors

Standard Power Ratings Of 3-Phase Motors


50-60 Hz In Category Ac-3(Ø ≤ 60 °C)

220V 380V Rated Operational Current


415V 440V Auxillary
230V 400V In Ac-3 440V Up To
Model Configuration
kW kW kW kW A
Connection by screw clamp terminals
LC1 D09** 2.2 4 4 4 9 1NO+1NC

LC1 D12** 3 5.5 5.5 5.5 12 1NO+1NC

LC1 D18** 4 7.5 9 9 18 1NO+1NC

LC1 D25** 5.5 11 11 11 25 1NO+1NC

LC1 D32** 7.5 15 15 15 32 1NO+1NC

LC1 D38** 9 18.5 18.5 18.5 38 1NO+1NC

Power connections by EverLink® BTR screw connectors(4) and control by spring terminals
LC1 D40A** 11 18.5 22 22 40 1NO+1NC

LC1 D50A** 15 22 25 30 50 1NO+1NC

LC1 D65A** 18.5 30 37 37 65 1NO+1NC

Connection by screw clamp terminals or connectors


LC1 D80A** 22 37 45 55 80 1NO+1NC

LC1 D95A** 25 45 45 55 95 1NO+1NC

LC1 D115A** 30 55 59 75 115 1NO+1NC

LC1 D150A** 40 75 80 90 150 1NO+1NC

Connection by lugs or bars


In the references selected above, insert a figure 6 before the voltage code.
Example: LC1 D09•• becomes LC1 D096••

Notes:
**Please refer to the table below for coil sizes.
- Standard control circuit voltages (for other voltages, please consult your local branch).

TeSys Contactors Separate Components


Auxiliary Contact Blocks and Add-on Modules

AC Supply

Volts 24 48 110 230 400 500

LC1 D09…D150 (D115 And D150 Coils With Built-In Suppression as Standard, by Bi-Directional Peak Limiting Diode).

50/60 Hz B7 E7 F7 P7 V7 S7

LC1 D80…D115

50 Hz B5 E5 F5 P5 V5 S5

60 Hz B6 E6 F6 - - -

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 121
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Replacement Coils for D-Range

AC coils for TeSys D, 3 or 4-pole contactors

For~contactors LC1 D09...D38


Specifications
Average consumption at 20 °C:
- inrush (cos = 0.75) 70 VA, LXD1••
- sealed (cos = 0.3) 50 Hz: 7 VA, 60 Hz: 7.5 VA
Operating range (ø≤ 60 °C): 50 Hz: 0.8…1.1 Uc, 60 Hz: 0.85…1.1 Uc.

Control Circuit Average Resistance At Inductance Of


Model Voltage Uc 20 °C ± 10 % Closed Circuit Product Code

V Ω H

50/60 Hz

LXD 1J7 12 1.33 0.05 D14685

LXD 1B7 24 5.37 0.22 D2023

LXD 1E7 48 21.7 0.87 D2024

LXD 1F7 110 124.1 4.6 D2025

LXD 1P7 230 538.6 20 D14686

LXD 1N7 415 1694 65 D14687

LXD 1S7 500 2499 95 D2028

AC coils for TeSys D, 3 or 4-pole contactors

For~contactors LC1 D40A...D65A


Specifications
Average consumption at 20 °C:
- inrush (cos = 0.75) 160 VA,
- sealed (cos = 0.3) 50 Hz: 15 VA, 60 Hz: 15 VA LXD 3••
Operating range (ø≤ 60 °C): 50 Hz: 0.8…1.1 Uc, 60 Hz: 0.85…1.1 Uc.

Control Circuit Average Resistance At Inductance Of


Voltage Uc 20 °C ± 10 % Closed Circuit
Product Code
Model
V Ω H

50/60 Hz

LXD 3J5 (2) 12 0.49 0.49 D14688

LXD 3B7 24 1.98 1.98 D14689

LXD 3E7 48 7.97 7.97 D14690

LXD 3F7 110 42.28 42.28 D14691

LXD 3P7 230 192 192 D14692

LXD 3N7 415 635 635 D14693

LXD 3S7 500 878 878 D14694

Note:
- The last 2 digits in the reference represent the voltage code.
- This coil can only be used on 50 Hz.

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
122 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Replacement Coils for D-Range

AC coils for TeSys D, 3 or 4-pole contactors

For 3 or 4-pole contactors LC1D40, D50, D65, D80, D95

Specifications
Average consumption at 20 °C:
- inrush (cos = 0.75) 50 Hz: 200 VA, 60 Hz: 220 VA LXD 6••
- sealed (cos = 0.3) 50 Hz: 20 VA, 60 Hz: 22 VA
Operating range (ø≤ 55 °C): 0.85…1.1 Uc.

Control Circuit Average Resistance At Inductance Of


Voltage Uc 20 °C ± 10 % Closed Circuit
Model Product Code

V Ω H

50/60 Hz

LX1 D6B7 24 1.22 0.08 D146795

LX1 D6E7 48 5 0.32 D14676

LX1 D6F7 110 26 1.7 D2034

LX1 D6P7 230/240* 115 7.7 D14677

LX1 D6V7 415 349 23 D14678

Note:
- The last 2 digits in the reference represent the voltage code.
* This coil can be used on 220/240 V at 50 Hz and on 240 V only at 60 Hz.

AC coils for TeSys D, 3 or 4-pole contactors

For 3 or 4-pole contactors LC1, D115, LC1 D150

Specifications
Average consumption at 20 °C:
- inrush cos = 0.9 - 280 to 350 VA,
LX1 D8••
- sealed cos = 0.9 - 2 to 18 VA.
Operating range (ø≤ 55 °C): 0.8…1.15 Uc.
Coils with integral suppression device fitted as standard, class B.

Control Circuit Average Resistance At Inductance Of


Model Voltage Uc 20 °C ± 10 % Closed Circuit Product Code

V Ω H

50/60 Hz

LX1 D8B7 24 147 3.03 D14679

LX1 D8E7 48 1061 24.19 D14680

LX1 D8F7 110 4377 109.69 D14681

LX1 D8P7 230 9895 210.72 D14682

LX1 D8N7 415 21 011 482.42 D14683

LX1 D8S7 500 32 249 938.41 D14684

Note:
The last 2 digits in the reference represent the voltage code.

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 123
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
TeSys D-Range Contactor Accessories
Instantaneous auxiliary contact blocks

Instantaneous auxiliary contact blocks for connection by screw clamp terminals:


For use in normal operating environments.
In order to mount an LAD 8N on an LC1 D80 to D95, a set of shims must be ordered separately.

Number Of Contacts Per


Model Clip-On Mounting (1) Description Product Code
Block

LAD N10 1NO+0NC D1901


1
LAD N01 0NO+1NC D1899

LAD N11 1NO+1NC D1902

LAD N20 2 2NO+0NC D1903

LAD N02 0NO+2NC D14646


Front
LAD N22 2NO+2NC D1904

LAD N13 1NO+3NC D14647

LAD N40 4 4NO+0NC D2744

LAD N04 0NO+4NC D1900

LAD N31 3NO+1NC D1905

LAD 8N11 1NO+1NC D14648

LAD 8N20 Side 2 2NO+0NC D14649

LAD 8N02 0NO+2NC D14650

Time delay auxiliary contact blocks


Mechanical latch blocks
Time delay auxiliary contact blocks for connection by screw clamp terminals
LAD T0 and LAD R0: with extended scale from 0.1 to 0.6 s.
LAD S2: with switching time of 40ms ±15ms between opening of the N/C contact and closing of the N/O contact

LAD T•3 LAD 6K10•


LAD T•

Time Delay
Model Clip-On Mounting Number Of Contacts Product Code
Type Setting Range

LAD T0 0.1…3 s D14645

LAD T2 0.1…30 s D1909


On-delay
LAD T4 10…180 s D1910

LAD S2 Front 1 N/O + 1 N/C 1…30 s D1908

LAD R0 0.1…3 s D3077

LAD R2 Off-delay 0.1…30 s D1906

LAD R4 10…180 s D1907

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
124 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
TeSys D-Range Contactor Accessories
Component parts for assembling reversign contactors for motor control, low-speed/high-speed starters and star-delta starters
For 3-Pole reversing contactors for motor control
Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer.

LAD 9R1 LAD 9R3 LA9 D 8069

For Contactors (1) Product


Model Description (2 Identical Contactors) Code

Kits for Assembly of Reversing Contactors

Kit Comprising:
LAD 9R1V • a mechanical interlock LAD 9V2 with electrical interlocking LAD 9V1. LC1 D09 to D38 D1911
• a set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing)

Kit Comprising:
LAD 9R1 • a mechanical interlock LAD 9V2 without electrical interlocking LC1 D09 to D38 D14659
• a set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing)

Kit Comprising:
LAD 9R3 • mechanical interlock LAD 4CMa, LC1 D40A to D65A D14660
• 9a set of power connections LA9 D65A6

LAD 9V2 LC1 D09 to D38 D1912

LAD 4CM LC1 D40A to D65A D4608

Mechanical interlock without integral electrical interlocking

LA9 D50978 LC1 D80 and D95 (~) D8074

LA9 D80978 LC1 D80 and D95 (­­ ) D14661

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 125
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
TeSys F-Range Contactors

TeSys F contactors for motor control in utilisation category AC-3 (115 to 800 A)
Control circuit: AC or DC

LC1 F225 LC1 F630

3-Pole Contactors

Standard Power Ratings Of 3-Phase Motors


50-60 Hz In Category Ac-3(Ø ≤ 60 °C)

Rated
220V 380V Operational Current
230V 400V 415V 440V
Type In AC-3 440 V Auxiliary Product Code
Up To Configuration
kW kW kW kW A
LC1 F115** 30 55 59 59 115 1NO+1NC D1959

LC1 F150** 40 75 80 80 150 1NO+1NC D14668

LC1 F185** 55 90 100 100 185 1NO+1NC D3017

LC1 F225** 63 110 110 110 225 1NO+1NC D3018

LC1 F265** 75 132 140 140 265 1NO+1NC D3019

LC1 F330** 100 160 180 200 330 1NO+1NC D14669

LC1 F400** 110 200 220 250 400 1NO+1NC D14670

LC1 F500** 147 250 280 295 500 1NO+1NC D14671

LC1 F630** 200 335 375 400 630 1NO+1NC D14672

LC1 F780** 220 400 425 425 780 1NO+1NC D14673

LC1 F800** 250 450 450 450 800 1NO+1NC D14674

Note:
** Refer to table below for coil voltage.

Volts ~ 24 48 110 230 415

LC1 F115…F225 B5 E5 F5 P5 N5
50 Hz (coil LX1)

60 Hz (coil LX1) E6 F6

40…400 Hz (coil LX9) E7 F7 P7 N7

LC1 F265…F330 B7 E7 F7 P7 N7
40…400 Hz (coil LX1)

LC1 F400…F630 E7 F7 P7 N7
40…400 Hz (coil LX1)

LC1 F780 F7 P7 N7
40…400 Hz (coil LX1)

LC1 F800 FW MW QW
40…400 Hz (coil LX4) (4)

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
126 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Replacement Coils for F-Range

AC 50/60 Hz Supply Coils


Specification
- Average consumption at 20°C:
- inrush 50Hz: 550VA; 60Hz: 660 VA,
- sealed 50Hz: 45VA; 60 Hz: 55 VA, cos ø = 0.3.
- Heat dissipation: 12…16 W.
- Operating time at Uc: closing = 23…35 ms, opening = 5…15 ms.

References
- Maximum ambient air temperature: 55 °C.
- Operating cycles/hour (ø ≤ 55 °C): ≤ 2400.

LX1 FF•••

Control Circuit
Voltage Average Resistance at Inductance of Closed
20 °C ± 10 % Circuit Product
Model Voltage Code
Code
Uc - 50 Hz

V Ω H
For contactors LC1, F115 and LC1, F150

LX1 FF024 24 0.27 0.04 B5 D14662

LX1 FF048 48 1.17 0.16 E5 D14663

LX1 FF110 110 6.38 0.86 F5 D14664

LX1 FF220 220 28.1 3.44 P5 D2042

LX1 FF415 415 95.1 12 N5 D2043

LX1 FF500 500 141 17 S5 D2044

LX1 FG•••

Control Circuit
Voltage Average Resistance at Inductance Of Closed
Model 20 °C ± 10 % Circuit Voltage Code Product Code
Uc - 50 Hz
V Ω H
For Contactors LC1, F185 and LC1, F225

LX1 FG024 24 0.18 0.03 B5 D2045

LX1 FG048 48 0.71 0.12 E5 D14665

LX1 FG110 110 4.18 0.65 F5 D3294

LX1 FG220 230 16.5 2.59 P5 D2046

LX1 FG415 415 62.3 9.06 N5 D14666

LX1 FG500 500 82.7 12.8 S5 -

Note:
• Items above with (-) in the codes column are available on special request

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 127
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
Replacement Coils for F-Range

TeSys F ontactors AC 40 to 400 Hz Supply Coils

Specification
Average consumption at 20 °C for 50 or 60 Hz and cos ø =0.9:
- inrush: 600…700 VA,
- sealed: 8…10 VA.
Operating time at Uc: closing = 40…65 ms, opening = 100…170 ms.

References
- Low sealed consumption.
- Operate on networks with harmonic numbers ≤ 7.
- Operating cycles/hour (ø≤ 55 °C): ≤2400. LX1 FH•••2

Control Circuit Average Resistance At 20 °C ± 10 % Inductance Of


Model Voltage Inrush Sealed Closed Circuit Voltage Code Product Code
V Ω Ω H
For Contactors LC1 F265 and LC1 F330
LX1 FH0242 24 0.8 20 (1) B7 D14640
LX1 FH0482 48 2.96 67 (1) E7 D14641
LX1 FH1102 110 18.7 440 (1) F7 D3295
LX1 FH2202 230 70.6 1578 (1) P7 D3293
LX1 FH3802 415 217 4631 (1) N7 D2048
LX1 FH5002 480/500 329 8543 (1) S7 D14642

TeSys F ontactors AC 40 to 400 Hz Supply Coils

Specification
Average consumption at 20 °C for 50 or 60 Hz and cos ø =0.9:
- Inrush: 1000…1150 VA,
- Sealed: 12…18 VA.
Operating time at Uc: closing = 40…65 ms, opening = 100…170.

LX1 FJ•••

Control Circuit Average Resistance At 20 °C ± 10 % Inductance Of


Model Voltage Inrush Sealed Closed Circuit Voltage Code Product Code
V Ω Ω H
For Contactors LC1 F400
LX1 FJ048 48 1.6 29.5 0.18 F7 D14643
LX1 FJ110 110/120 9.8 230 1.35 F7 D2049
LX1 FJ220 230 37 1030 5.1 P7 D2050
LX1 FJ415 415 145 4070 19.4 N7 -
LX1 FJ500 500 190 4980 25.5 S7 D14644

TeSys F Contactors AC 40 to 400 Hz Supply Coils

Specification
Average consumption at 20 °C for 50 or 60 Hz and cos ø =0.9:
- inrush: 1050…1150 VA,
- sealed: 16…20 VA.
Operating cycles/hours (ø ≤ 55°C): ≤2400.
Heat dissipation:18 W.
Operating time at Uc: closing = 40…75 ms, opening = 100…170 ms.

References
Low sealed consumption.
Operate on networks with harmonic numbers ≤ 7. LX1 FK•••

Control Circuit Average Resistance At 20 °C ± 10 % Inductance Of


Model Voltage Inrush Sealed Closed Circuit Voltage Code Product Code
V Ω Ω H
For Contactors LC1 F500
LX1 FK048 48 1.9 33.5 0.19 E7 D14631
LX1 FK110 110/120 9.55 260 1.25 F7 D14632
LK1 FK220 230 35.5 915 4.55 P7 D12280
LX1 FK415 415 143 3730 18.4 N7 D14633
LX1 FK500 500 172 4590 22.8 S7 D14634

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
128 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS

TeSys F ontactors AC 40 to 400 Hz Supply Coils

Specification
Average consumption at 20 °C for 50 or 60 Hz and cos ø =0.9:
- inrush: 1500…1730 VA,
- sealed: 20…25 VA.
Operating cycles/hours (ø ≤ 55°C): ≤1200.
Heat dissipation: 20 W.
Operating time at Uc: closing = 40…80 ms, opening = 100…200 ms.

LX1 FL•••

Control Circuit Average Resistance At 20 °C ± 10 % Inductance Of


Model Voltage Inrush Sealed Closed Circuit Voltage Code Product Code
V Ω Ω H
For Contactors LC1 F630 and LC1 F800

LX1 FL048(1) 48 1.1 17.1 0.09 E7 D14635

LX1 FL110 110/120 6.45 165 1.85 F7 D14636

LK1 FL220 230 25.5 730 3.35 P7 D14637

LX1 FL415 415 96 2960 13 N7 D14638

LX1 FL500 500 120 3660 16.5 S7 D14639

Note:
(1) Incompatible with LC1F1250.
- Higher amperage available

TeSys F-Range Contactors Accessories


TeSys F contactors, Auxiliary contact blocks
Instantaneous auxiliary contact blocks with dust and damp protected contacts
Recommended for use in particularly harsh industrial environments

Maximum Number Of
Number Of Blocks Per Contactor Product
Model Description
Contacts Code
Clip-On Mounting

LAD N10 1NO+0NC D1901


1 1
LAD N01 0NO+1NC D1899
LAD N11 1NO+1NC D1902
LAD N20 2 2 2NO+0NC D1903
LAD N02 0NO+2NC D14646
LAD N22 2NO+2NC D1904
LAD N13 1NO+3NC D14647
LAD N40 4 2 4NO+0NC D2744
LAD N04 0NO+4NC D1900
LAD N31 3NO+1NC D1905

Time delay auxiliary contact blocks

Mximum Number Of
Time Delay
Number Of Blocks Per Contactor Product
Reference
Contacts Code
Clip-On Mounting Type Range
LAD T2 0.1...30 D1909
On-delay
LAD T4 1 N/O 10...180 D3075
+ 2
LAD R2 1N/C 0.1...30 D1906
Off-delay
LAD R4 10...180 D1907

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 129
MOTOR CONTROL AND ACCESSORIES

OVERLOADS
TeSys Thermal Motor Protection Overload Relays for D-Range Contactors
TeSys D, 3-pole thermal overload relays
Differential thermal overload relays
for use with fuses or magnetic circuit-breakers GV2 L and GV3 L
• Compensated relays with manual or automatic reset,\
• with relay trip indicator,
• for AC or DC

LRD•• LRD 3•• LRD 33•• LRD 3••6

For Use With


Model Relay Setting Range (A) Product Code
Contactor LC1

Class 10 A (1) For Connection By Screw Clamp Terminals Or Connectors

LRD 01 0.10...0.16* D09...D38 D14651


LRD 02 0.16...0.25* D09...D38 D2787D
LRD 03 0.25...0.40* D09...D38 D14652
LRD 04 0.40...0.63* D09...D38 D1973
LRD 05 0.63...1* D09...D38 D1974
LRD 06 1...1.6 D09...D38 D1975
LRD 07 1.6...2.5 D09...D38 D1976
LRD 08 2.5...4 D09...D38 D1977
LRD 10 4...6 D09...D38 D1978
LRD 12 5.5...8 D09...D38 D1979
LRD 14 7...10 D09...D38 D1780
LRD 16 9...13 D12...D38 D1781
LRD 21 12...18 D18...D38 D1782
LRD 22 16...24 D25...D38 D1783
LRD 32 23...32 D25...D38 D1784
LRD 35 30...38 D32 and D38 D1785

Class 10 A (1) For Connection Byever Link® Btr Screw Connectors (3)

LRD 313 9...13 D40A...D65A D14653


LRD 318 12...18 D40A...D65A D14654
LRD 325 17...25 D40A...D65A D14655
LRD 332 23...32 D40A...D65A D14656
LRD 340 30...40 D40A...D65A D4753
LRD 350 37...50 D40A...D65A D14657
LRD 365 48...65 D50A and D65A D14658

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
130 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

THERMAL AND ELECTRONIC OVERLOADS


TeSys Thermal Motor Protection Overload Relays for D-Range Contactors

For Use With


Model Relay Setting Range (A) Product Code
Contactor LC1

Class 10 A (1) For Connection By Screw Clamp Terminals Or Connectors


LRD 3322 17...25 D80 and D95 D1985
LRD 3353 23...32 D80 and D95 D1986
LRD 3355 30...40 D80 and D95 D1987
LRD 3357 37...50 D80 and D95 D1988
LRD 3359 48...65 D80 and D95 D1989
LRD 3361 55...70 D80 and D95 D1990
LRD 3363 63...80 D80 and D95 D1991
LRD 3365 80...104 D80 and D95 D1992
LRD 4365 80...104 D115 and D150 D1994
LRD 4367 95...120 D115 and D150 D1995
LRD 4369 110...140 D150 D2276

Note:
* Independant mounting only; use LA7D3064

TeSys Electronic Motor Protection Overload Relays For F-Range Contactors

3-Pole electronic thermal overload relays, TeSys LR9 F for motor protection

LR9 F53•• LR9 F73••

Relay Setting Range


For Direct Mounting Beneath
Model Product Code
Contactor Lc1
A
Class 10 (2)
LR9 F5357 30…50 F115…F185 D14714

LR9 F5363 48…80 F1 15…F185 D14715

LR9 F5367 60…100 F1 15…F185 D14716

LR9 F5369 90…150 F1 15…F185 D14717

LR9 F5371 132…220 F185…F400 D5048

LR9 F7375 200…330 F225…F500 D14718

LR9 F7379 300…500 F225…F500 D14719

LR9 F7381 380…630 F400…F630 and F800 D14720

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 131
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Thermal-Magnet Motor Circuit Breakers 0.06...15kW

Thermal-magnetic circuit-breakers GV2-ME for connection by screw clamp terminals


GV2-ME with pushbutton control, GV2-P control by rotary knob

Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting Magnetic
Range of Tripping Product
400/415 V 500 V thermal trips Current Code
Model
P Icu Ics(1) P Icu Ics(1)
A A(d±20%)
kW kA kW kA

GV2ME01 0.1…0.16 1.5 D14721

GV2ME02 0.06 * * 0.16…0.25 2.4 D14722

GV2ME03 0.09 * * 0.25…0.40 5 D1884

GV2ME04 0.12 * * 0.40…0.63 8 D1885

GV2ME05 0.25 * * 0.63…1 13 D1886

GV2ME06 0.37 * * 0.37 * * 1…1.6 22.5

GV2ME06 0.55 * * 0.55 * * 1…1.6 22.5 D1887

GV2ME06 0.75 * * 1…1.6 22.5

GV2ME07 0.75 * * 1.1 * * 1.6…2.5 33.5


D1888
0.75 * * 1.1 * * 1.6…2.5 33.5

GV2ME08 1.1 * * 1.5 * * 2.5…4 51

1.1 * * 1.5 * * 2.5…4 51


D889
GV2ME08 1.5 * * 2.2 * * 2.5…4 51

1.5 * * 2.2 * * 2.5…4 51

GV2ME10 2.2 * * 3 50 100 4…6.3 78


D1890
2.2 * * 3 * * 4…6.3 78

GV2ME14 3 * * 4 10 100 6…10 138

3 * * 4 50 100 6…10 138


D1891
GV2ME14 4 * * 5.5 10 100 6…10 138

4 * * 5.5 50 100 6…10 138

GV2ME16 5.5 15 50 7.5 6 75 9…14 170

5.5 * * 7.5 42 75 9…14 170


D1892
GV2ME16 9…14 170

9…14 170

GV2ME20 7.5 15 50 9 6 75 13…18 223


D1893
7.5 50 50 9 10 75 13…18 223

GV2ME21 9 15 40 11 4 75 17…23 327


D1894
9 50 50 11 10 75 17…23 327

GV2ME22 (2) 11 15 40 15 4 75 20…25 327


D1895
11 50 50 15 10 75 20…25 327

GV2ME32 15 10 50 18.5 4 75 24…32 416


D1896
15 50 50 18.5 10 75 24…32 416

Note:
* >100kA
(1) as % of Icu
(2) Combined with a recommended contactor

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
132 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Magnetic Circuit Breakers

Magnetic circuit-breakers GV2-L for connection by screw clamp terminals


GV2-LE control by rocker lever, GV2-L control by rotary knob

Magnetic Tripping
Standard power ratings of 3-Phase motors 50/60Hz in category AC-3 Use in association with thermal Product
protection Current
Code
Model
400/415V 500V 690V
Rating d±20% overload relay
P Icu Ics(1) P Icu Ics(1) P Icu Ics(1)
kW kA kW kA kW kA A A Model Product Code
GV2LE03 0.06 * * 0.4 5 LR2K0302 D14792 D14756

GV2LE03 LR2K0304 or D14793 D14756


0.09 * * 0.4 5
GV2L03 LRD03 D14652 D14768

GV2LE04 LR2K0304 or D14793 D14757


0.12 * * 0.37 * * 0.63 8
GV2L04 LRD04 D1973 D14769

GV2LE04 LR2K0305 or D14794 D14757


0.18 * * 0.63 8
GV2L04 LRD04 D1973 D14769

GV2LE05 LR2K0305 or D14794 D14758


0.55 * * 1 13
GV2L05 LRD05 D1974 D14770

GV2LE05 LR2K0306 or D2018 D14758


0.25 * * 1 13
GV2L05 LRD05 D1974 D14770

GV2LE05 LR2K0306 or D2018 D14758


0.75 * * 1 13
GV2L05 LRD06 D1975 D14770

GV2LE06 LR2K0306 or D2018 D14759


0.37 * * 0.37 * * 1 13
GV2L06 LRD05 D1974 D14771

GV2LE06 LR2K0307 or D2019 D14759


0.55 * * 0.55 * * 1.1 * * 1.6 22.5
GV2L06 LRD06 D1975 D14771

LR2K0307 or D2019
GV2LE07 0.75 * * 1.6 22.5 D14760
LRD06 D1975
GV2L07 0.75 * * 1.1 * * 1.5 2.5 33.5 LR2K0308 D2020 D14760
GV2LE08 D14761
0.75 * * 1.1 * * 1.5 2.5 33.5 LRD07 D1976
GV2L08 D14773

LR2K0308 or D2020
GV2LE08 1.1 * * 2.5 33.5 D14761
LRD08 D1977
GV2L08 1.5 1.5 * * 3 3 75 4 51 LR2K0310 D14795 D14773
GV2LE08 1.5 * * 1.5 * * 3 4 100 4 51 LRD08 D1977 D14761

LR2K0312 or D14796
GV2L08 2.2 4 51 D14773
LRD08 D1977
GV2LE10 2.2 * * 3 50 100 4 3 75 6.3 78 LR2K0312 D14796 D14762
GV2L10 2.2 * * 3 * * 4 4 100 6.3 78 LRD10 D1978 D14774
GV2LE14 3 * * 4 10 100 5.5 3 75 10 138 LR2K0314 D14797 D14763
GV2L14 3 * * 4 10 100 5.5 4 100 10 138 LRD12 D1979 D14775

GV2LE14 LR2K0316 or D14798 D14763


4 * * 5.5 10 100 10 138
GV2L14 LRD14 D1980 D14775
GV2LE14 7.5 3 75 10 138 LRD14 D1980 D14763
GV2L14 7.5 4 100 10 138 LRD14 D1980 D14775
GV2LE16 9 3 75 14 170 LRD16 D1981 D14764
GV2L16 9 4 100 14 170 LRD16 D1981 D14776
GV2LE16 5.5 15 50 7.5 6 75 11 3 75 14 170 LR2K0321 D14799 D14764
GV2L16 5.5 50 50 7.5 10 75 11 4 100 14 170 LRD16 D1981 D14776
GV2LE20 7.5 15 50 9 6 75 15 3 75 18 223 LRD21 D1982 D14765
GV2L20 7.5 50 50 9 10 75 15 4 100 18 223 LRD21 D1982 D14777
GV2LE22 9 15 40 11 4 75 18.5 3 75 25 327 LRD22 D1983 D14766
GV2L22 9 50 50 11 10 75 18.5 4 100 25 327 LRD22 D1983 D14778
GV2LE22 11 15 40 15 4 75 25 327 LRD22 D1983 D14766
GV2L22 11 50 50 15 10 75 25 327 LRD22 D1983 D14778
GV2LE32 15 10 50 18.5 4 75 22 3 75 32 416 LRD32 D1984 D14767
GV2L32 15 50 50 18.5 10 75 22 4 100 32 416 LRD32 D1984 D14779

Note:
* >100kA (1) as % of Icu Common accessories GV2 / GV3
For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 133
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Thermal-Magnet and Magnetic Motor Circuit-breakers
with Screw Clamp Connections Accesories

GV3 APN02

Sold in Weight
Model Description Application Product Code
lots of kg
For mounting a GV2 ME or GV2 LE by screw
GV2 AF02 10 0.021 D14695
fixing
Adapter plates
For mounting a GV2 ME or GV2 P and contactor
LAD 311 1 0.040 D14696
LC1 D09...D38 with front faces aligned

GV1 F03 Height compensation plate 7.5mm 10 0.003 D14697

Between GV2 and a contactor LC1 K or LP1 K


GV2 AF01 10 0.020 D14591

GV2 AF3 Combination blocks Between GV2 and a contactor LC1 D09...D38 D3340

Between GV2 mounted on LAD 311 an


GV2 AF4 D14699
contactor LC1 D09...D38

With 3-pole connection for mounting a GV2


GK2 AF01 Motor starter adapter plates 1 0.120 D14700
and a contactor LC1 D09...D25

Pitch Weight
Model Description Application Product Code
mm kg
GV2 G245 45 0.038 D14701
GV2 G254 2 tap-offs 54 0.038 D14592
GV2 G272 72 0.042 D14702
GV2 G345 45 0.058 D14703
Sets of 3-pole 3 tap-offs
GV2 G354 54 0.060 D14704
63A busbars
GV2 G445 45 0.077 D10705
GV2 G454 4 tap-offs 54 0.085 D1881
GV2 G472 72 0.094 D14706
GV2 G554 5 tap-offs 54 0.100 D14698

Sold in lots Weight


Model Description Application Product Code
of kg
GV1 G10 Protective end cover For unused busbar oulets 5 0.005 D14707

GV1 G09 Terminal block Connection from the top 1 0.040 D14708
(for supply to one or more GV2 G
Can be filled with current limiter GV1 L3 (GV2
GV2 G05 busbar sets) 1 0.115 D1880
ME and GV2 P)
LA9 E07 Cover for terminal block For mounting in modular panels 10 0.005 D14709
Flexible 3-pole connection (for
Centre distance between mounting rails:
GV1 G02 connecting a GV2 to a contactor 10 0.013 D14710
100...120mm
LC1-D09...D25
Set of connections (upstream/ For connecting GV2 ME to a printed circuit
GV2 GA01 10 0.045 D14711
downstream). board
"Large Spacing" adapter UL 508
GV2 GH7 For GV2••HP (except 32A) 1 0.040 D14712
type E
Clip-in marker holders (supplied
LA9 D92 For GV2 P, GV2 L, GV2 LE and GV2 RT (8x22mm) 100 0.001 D14713
with each circuit-breaker)

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
134 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Thermal-Magnet and Magnetic Motor Circuit-breakers
with Screw Clamp Connections Accesories
Product Information

Extended Rotary Handle


Allows a circuit-breaker or a starter-controller installed in back of an enclosure to be operated from the front of the enclosure.
A rotary handle can be black or red/yellow, IP54 or IP65. It includes a function for locking the circuit-breaker or the starter in the O (off) or I (on) position
(depending of the type of rotary handle) by means of up to 3 padlocks with shank diameter of 4 to 8mm. The extended shaft must be adjusted to use in
different size enclosures. The IP54 rotary handle is fixed with a nut (ø22) to make easier the assembling. The new Laser Square tool brings the accuracy to
align the circuit breaker and the rotary handle.

Padlock external operators for GV2P and GV2L

Description
1 Kit hanle + mounting system
2 Universal handle
3 Shaft
4 Bracket
5 Shaft support plate for deep enclosure
6 Retrofit accessory
7 Laser square accessory

Kit handle + mounting system


Model Description Item Weight Product Code
GV2 APN01 Black handle, front plate, with trip status, IP54 1 0.300 D14780
GV2 APN02 Red handle, front plate, with trip status, IP54 1 0.300 D14593
GV2 APN04 Red handle, front plate, without trip status, IP64 1 0.300 D14781
Padlocking in "On" and "Off" position
GV2 AP03 0.280 D14782
Black handle, blue ffront plate, IP54
Kit handle + mounting system
GV APB54 Black handle, IP54 2 0.140 D14783
GV APR54 Red handle, IP54 2 0.140 D14784
GV APR64 Red handle, IP64 2 0.140 D14785
Shaft
GV APA1 For GV2 P/L L = 315mm 3 0.110 D14786

Bracket
GV APH02 For GV2 P/L 4 0.300 D14787

Shaft support plate for deep enclosure


GV APK11 For GV2 P/L Depth > 250mm 5 0.030 D14788

Retrofit accessory
GV APP1 For GV2 P/L 6 0.100 D14789

Laser Square accessory


GV APL01 For GV2 P/L 7 0.160 D14790

Stcker Sold in lots


GV APSFR Warning label For French 10 -
GV APSEN For English 10 D14791
GV APSDE For German 10 -
GV APSES For Spanish 10 -
GV APSCN For Chinese 10 -
GV APSPT For Portuguese 10 -
GV APSRU For Russian 10 -
GV APSIT For Italian 10 -
Padlocking device
Model Description Weight Product Code
For all GV2 device
GV2 V03 0.092 D14594
For use with up to 4 padlocks, ø6mm shank max. (padlocks not included)

Contact Blocks
Model Description Type of contacts Weight Product Code
GV AE1 N/O or N/C (1) 0.015 D14723
GV AE11 (2) N/O or N/C 0.020 D1868
GV AE20 (2) Instantaneous auxiliary contacts N/O or N/O 0.020 D14724
GV2 AN11 N/O or N/C 0.050 D1869
GV2 AN20 N/O or N/O 0.050 D14725

GV AED101 (2) N/O (fault) +N/O 0.020 D14726


GV AED011 (2) N/O (fault) +N/O 0.020 D14727
GV AD1010 Fault signalling contact + instantaneous +N/O 0.055 D14728
N/O (fault)
GV AD1001 auxiliary contact +N/C 0.055 D14729
GV AD0110 +N/O 0.055 D14730
N/O (fault)
GV AD0101 +N/C 0.055 D14731
GV AM11 Short-circuit signalling contact C/O common point 0.045 D14732

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 135
MOTOR CONTROL AND ACCESSORIES

MOTOR CIRCUIT BREAKERS


Thermal-Magnet and Magnetic Motor Circuit-breakers
with Screw Clamp Connections Accesories

Electric trips - undervoltage or shunt (4)


Model Mounting Voltage Weight Product Code
GV A•025 50Hz 0.105 D14733
24V
GV A•026 60Hz 0.105 D14734
GV A•055 50Hz 0.105 D14735
48V
GV A•056 60Hz 0.105 D14736
GV A•107 100 50Hz 0.105 D14737
GV A•107 100...110V 60Hz 0.105 D14737
GV A•115 50Hz 0.105 D14738
110...115V
GV A•116 60Hz 0.105 D14739
GV A•125 120...127V 50Hz 0.105 D14740
GV A•115 127V 60Hz 0.105 D14728
GV A•207 Side 200V 50Hz 0.105 D14741
GV A•207 (1 block on RH side of circuit-breaker) 200V...220V 60Hz 0.105 D14741
GV A•225 50Hz 0.105 D14742
220V...240V
GV A•226 60Hz 0.105 D14743
GV A•385 50Hz 0.105 D14744
380V...400V
GV A•386 60Hz 0.105 D14745
GV A•415 415V...440V 50Hz 0.105 D14746
GV A•416 415V 60Hz 0.105 D14747
GV A•385 440V 50Hz 0.105 D14744
GV A•415 480V 60Hz 0.105 D14746
GV A•505 500V 50Hz 0.105 D14748
GV A•505 600V 60Hz 0.105 D14748
Accessories
Model Description Voltage Weight Product Code
GV3 G264 Sets of 3-pole 2 tap-off GV3 P•• and GV3 L•• 0.150 D14749
115A busbars 3 tap-off
GV3 G364
Pitch: 64mm
GV3 P•• and GV3 L•• 0.250 D14750
Cover "Large Spacing" UL 508 type E
GV3 G66
(Only one cover required on supply side)
GV3 P•• 0.020 D14751
IP20 cover
LAD 96570
for use when mounted with circuit-breakers
GV3 P••6 and GV3 L••6 0.021 D14752
LAD 96575 Size 4 Allen key, insulated, 1000V GV3 P••6 and GV3 L••6 0.010 D14753
Padlocking device
LAD ALLEN4 (5) for use with up to 4 padlocks (not supplied) GV3 P•• and GV3 L•• 0.026 D14754
ø6mm shank max.
Retrofit plate Replacement of GV3 ME GV3 P•• and GV3 L••
GV2 V03
for screw fixing with GV3 P•• or GV2 P•• GV3 P••6 and GV3 L••6
0.092 D14594
LAD 7X3 0.150 D14755

Notes:
(1) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted.
(2) Contact blocks available in version with spring terminal connections. Add a figure 3 at the end of the references selected above.
Example: GV AED101 becomes GV AED1013.
(3) The GV AD•• is always mounted next to the circuit-breakers.
(4) To order an undervoltage trip: replace the dot(•) in the reference with a U, example: GV AU025.
To order a shunt trip: replace the dot(•) in the reference with a S, example: GV AS025.
(5) Sold in lots of 5.

TeSys Contactors Accessories


TeSys Enclosed Starters

Enclosed thermal-magnetic motor circuit-breakers


GV2 ME and accessories, for customer assembly.

GVC2 MC

Enclosures for thermal-magnetic circuit-breakers GV2 ME

Possible no of side
mounting auxiliary contact
Model Type Degree of protection blocks on GV2 ME Product code
Left Hand Right
Side Hand Side

Surface mounting, double


GV2 MC02 insulated with protective IP55 1 1 D1883
conductor. Sealable cover

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
136 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

CONTACTORS
TeSys Contactors Accessories
TeSys Protection Components

Thermal-magnetic and magnetic motor circuit-breakers GV2 with screw clamp connections accessories.

Accessories

Model Description Application Sold in lots of Product Code

Between GV2 and contactor LC1


GV2 AF01 10 D14591
K or LP1 K
Combination Blocks
Between GV2 and contactor LC1
GV2 AF3 10 D3340
D09...D38

Pitch
Model Description Application Product Code
(mm)

GV2 G254 2 tap-offs 54 D14592


Sets of 3-pole
63 A busbars
GV2 G454 4tap-offs 54 D1881

Model Description Product Code

Kit Handle and Mounting system

GV2 APN02 Red handle, front plate with trip status, IP54 D14593

Padlocking Device
For all GV2 Device
GV2 V03 For use with up to 4 padlocks, ø 6mm shank max. D14594
(padlocks not included)

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 137
MOTOR CONTROL AND ACCESSORIES

PUSH BUTTONS, SWITCHES AND PILOT LIGHTS


Push buttons, Switches and Pilot Lights Ø 22 with Metal Bezel

Pushbuttons, spring return


Type of head Chromium plated circular bezel

= +
Degree of protection IP66 / Nema 4X, 13 / Class 1
ø22.5 (22.4+0.4
0 recommended)
Mounting (mm)
30 (horizontal) x 40 (vertical)
Depth (mm) 43
Connection (!) Screw clamp terminals

Flush Flush Booted


Colours Auxiliary
Model Product Code Model Product Code
Unmarked
Black NO XB4BA21 D14612 XB4BP21 D14615
Green NO XB4BA31 D2724 XB4BP31 D14616
Red NO XB4BA42 D6982 XB4BP42 D14617
Yellow NO XB4BA51 D14613 XB4BP51 D14618
Blue NO XB4BA61 D14614 XB4BP61 D14619
With international marking

Green NO XB4BA3311 D14620

Red NC XB4BA4322 D14621

White NO XB4BA3341 D14622

Black NO XB4BA3351 D14623

Unmarked
Black NO XB4BC21 D14624
Red NC XB4BL42 D14625
With international marking
Double-headed pushbuttons Triple-headed pushbuttons
Degree of protection IP66 - IP69K IP66 - IP69K
Complete For user assembly Complete For user assembly

NO + NC XB4BL73415 ZB4BZ105 ZB4BL7341


ZB4BZ105
NO + NC + NO J14626 J14627 ZB4BA71123
+ ZBE102

Note:
- All of the above products complete.
- Please enquire at your nearest branch for parts.
- For a full range of Push Buttons Switches and Pilot lights, please enquire at you nearest branch.
- Type oh head: Chromium plated circular bezel
- IP Rating: IP66

Ø 40mm Mushroom Head Emergency Pushbuttons.

+
Trigger action (EN/ISO 13850)
Unmarked

Colours Auxiliary Model Product Code

Red NO + NC ZB4BT84 D14628

Red NO + NC ZB4BS844 D14629

Red NO + NC ZB4BS944 D14630

Note:
(2) Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850, to Machinery Directive
2006/42/EC and to standard EN/IEC 60947-5-5. Please consult your Regional Sales Office for a full explanation of these standards and directives.

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
138 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

PUSH BUTTONS, SWITCHES AND PILOT LIGHTS


Push buttons, Switches and Pilot Lights Ø 22 with Metal Bezel

Light functions

Pilot Lights
Circular bezel
Type of head
Smooth lens cap
Degree of protection

Mounting (mm)
IP66 / Nema 4X, 13 / Class 1
ø22.5 (22.4+0.4
0 recommended)
= +
30 (horizontal) x 40 (vertical)
Depth (mm) 43
Connection (!) Screw clamp terminals
Light source Integral LED

Pilot Lights
Supply voltage 230...240V AC
Colours Model Product Code
White XB4BVM1 D3093
Green XB4BVM3 D3094
Red XB4BVM4 D3095
Yellow XB4BVM5 D3096
Blue XB4BVM6 D3097

= +
Illuminated pushbuttons and selector switches
Supply voltage 230...240V AC
Colours Model Product Code
White XB4BW31M5 D14603
Green B4BW33M5 D14604
Red XB4BW34M5 D14605
Yellow XB4BW35M5 D14606
Blue XB4BW36M5 D14607

Illuminated Selector switches (2position Stay Put)


Supply voltage 230...240V AC
Colours Model Product Code
Green XB4BK123M5 D14608

Red XB4BK124M5 D14609

Yellow XB4BK125M5 D14610

Double-headed Pushbuttons with LED Pilot Light (1 Flush Green Push, 1 Projecting Red Push)
Supply voltage 230...240V AC
Colours Model Product Code
White XB4BW73731M5 D14611

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue. VOLTEX CATALOGUE 139
MOTOR CONTROL AND ACCESSORIES

MISCELLANEOUS
Separate Components and Accessories

Electrical blocks (1) (2)

Single contact blocks Light blocks with integral LED Light block, direct supply

Consumption
Rated operational characteristic AC-15, 240 V - 3A
24 V AC/
18 mA
DC

14 mA 120 V AC
Positive operation of contacts NC contacts with positive
conforming to IEC/EN 60947-5-1 opening operation
14 mA 240 V AC

To combine with heads for integral LED For BA 9s bulb (not included)
Screw Spring
clamp clamp
24 V AC/ 110…120 230…240
terminal terminal 250 V max., 2.4 W max.
DC V AC V AC

NC ZBE101 ZBE1015 white ZBVB1 ZBVG1 ZBVM1 ZBV6

NO ZBE102 ZBE1025 green ZBVB3 ZBVG3 ZBVM3 Colour provided by lens

References red ZBVB4 ZBVG4 ZBVM4

orange ZBVB5 ZBVG5 ZBVM5

blue ZBVB6 ZBVG6 ZBVM6

Diecast metal enclosures


1 vertical row 2 vertical rows
(Zinc alloy, usable depth 49 mm)
Number of
Front face dimensions 1 2 3 4 2 4 6
cut-outs

80 x 80 mm XAPM1201 - - - XAPM1202 - -

References 80 x 130 mm - XAPM2202 XAPM2203 - - XAPM2204 -

80 x 175 mm - - XAPM3203 XAPM3204 - - XAPM3206

For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes and
140 VOLTEX CATALOGUE product type for spec purposes. Refer to appendix for additional information, certification required and full technical specification from the supplier. All details provided are for indicative purposes only. Complete T & C's at back of catalogue.
MOTOR CONTROL AND ACCESSORIES

MISCELLANEOUS

Accessories
Legend holders, 30 x 40mm, for 8 x 27mm legends
white or
Marking Background colour: black or red
yellow

Blank ZBY2101 ZBY4101

0 (red
International ZBY2931 I ZBY2147 AUTO ZBY2115 STOP ZBY2304
background)

English OFF ZBY2312 ON ZBY2311 START ZBY2303 -


Models (10)* ARRET (red b/ ARRET-
French ZBY2104 ZBY2166 MARCHE ZBY2103 -
grnd) MARCHE

German AUS ZBY2204 AUS-EIN ZBY2266 EIN ZBY2203 -

PARADA (red PARADA-


Spanish ZBY2404 ZBY2466 MARCHA ZBY2403 -
b/grnd) MARCHA

Legend holders, 30 x 50 mm, for 18 x 27 mm legends


black or red white or yellow

Models (10)* Blank ZBY6101 ZBY6102

Ø 60 mm legend for mushroom head Emergency stop pushbutton


Background
Yellow
colour

Emergency Arret
Marking Blank Not Halt Parada De Emergencia
Stop D’urgence

References ZBY9140 ZBY9330 ZBY9130 ZBY9230 ZBY9430

Romeo Series Joystick Control Switches


Romeo joysticks are designed to control complex machine tools in heavy-duty and/or
aggressive environments. Rod movement in both directions can be customised.

• Simple, convrnient wiring and termination facility


• Conformity to standards: IEC.EN 60204-1, 60947-1, 60947-5-1, 61000-6-2/3

- Utilisation category: AC 15
- Rated operational current: 2A
- Rated operational voltge: 48 Vac
- Connections: screw type terminal

No. Steps
No. Steps
Lever Guide Description Model Product Code

With No Contact In The Handle Grip

1 1 111 Joystick Control Switch PF580L011003 D14595

2 0 4400 Joystick Control Switch PF580C020003 D14596

2 2 4444 Joystick Control Switch PF580L022003 D14597

3 0 6600 Joystick Control Switch PF580C030003 D14598

3 3 6666 Joystick Control Switch PF580L033003 D14599

4 4 4444 Joystick Control Switch PF580L044003 D14600

5 0 5500 Joystick Control Switch PF580C05003 D14601

5 5 5555 Joystick Control Switch PF580L055003 D14602