Professional Documents
Culture Documents
M18 DC Photoelectric Switches With Optional Diffuse Sensitivity Adjustment SS
M18 DC Photoelectric Switches With Optional Diffuse Sensitivity Adjustment SS
M New
els
Compact ø18mmx65mm barrel type
photoelectric switches for DC operation
od
■ Diffuse, retro-reflective, polarised, through-beam
models
■ Small object detection through-beam models
■ Diagnostic CHECK function available on through-beam
models
■ IP67 nickel-plated or output-type colour-coded plastic
3
housing
■ Optional sensitivity adjustment - diffuse type (IP65) Year
Guarantee
■ Rear mounted LED operation indicator
■ Short-circuit protection
■ UL approved option SS3+SS4 models, feature flush lenses as standard
S S 2 / A N – 0 A
Specifications
Type diffuse retro-reflective polarised through-beam
Models SS2 SS3 SS4/5 SS6/SS7 SSC SSP SSE-SSR SSU-SSG SSU-SSV
Sensing range Sn 10cm(1) 10cm(1) 20cm(2) 40cm(2) 2m(3) 2m(3) 8m(4) 8m(5) 3m(6)
Emission infra-red red infrared red
Hysteresis 10%
Repeatability 5%
Tolerance -5+15% -0+20%Sn -5+15% of sensing range Sn
Supply voltage 10 - 30 VDC ripple 10% max.
Max consumption 30mA 25mA 30m A trans 15mA (with CHECK 35mA) receiver 20mA
Response time 5ms 5ms 20ms 2ms
Output type NPN or PNP - NO or NC
Load current 100 mA
Residual output voltage 1.2V max. IL = 100 mA
Leakage current 10µA max. to 30VDC
Output current limit ~200 mA at 25˚C
Electrical protections against short circuit (autoreset) - polarity reversal - inductive loads
Time before switch operation 200 ms
LED status indicator yes (at the rear)
Insulation resistance >1000M Ohm to 1000VDC
Dielectric strength 2000VAC 50Hz for 1 Minute
Noise immunity 1000V (IEC 801-4, II) plastic housing, 500V (IEC801-4, I) metal housing
Protection degree IP67 IEC IP65 IEC IP67
Materials housing: plastic body - polyamide (nylon), metal body - nickel-plated brass, lenses: acrylic, cable exit: polycarbonate
Operating temperature -25˚ + 70˚C (without freeze)
Interference by external light 3000 lux (artificial light), 10000 lux (sunlight)
Tightening torque 1Nm (10 kgcm), (plastic housing) 40Nm (408 kgcm) (metal housing)
Ambient humidity 35-85% r.h.
Weight (approx.) 100g (plastic) 120g (metal) 200g (plastic) 240g (metal)
(1)
referred to 100x100mm white matt paper; (2) referred to 200x200mm white matt paper; (3) with ø80mm reflector (RL110 supplied separately); (4) minimum detectable target ø7.5mm;
(5)
minimum detectable target ø4mm; (6) minimum detectable target ø1mm
SS
S S 2 / A N – 0 E
8m standard receiver R
Please contact IMO for details of the many other options available, including small object detection and the SP range which gives
NO output state A right angle viewing with no loss of performance.
Note: SS3 and SS4 models are available with only type C or K cable exits (right angle cable and M12 right angle plug).
Transmitter without CHECK O Connectors – please see page 332
Dimensions (mm)
65
LED LED LED LED
M18x1
M18x1
14,5
Ø10.4
18 43 4 21
8 65 8 24 4 22
M12x1
■ Standard cable exit – Option A ■ Locking nut ■ Locking nut 6 12 43 4
(SS*/**-*A model) for plastic housing for nickel-plated housing
(SS*/**-1* model) ■ M12 right angle plug exit – Option K
(SS*/**-*K model)
65
LED LED
M18x1
LED LED
M18x1
Ø10.5
Ø8
10
5 18 18 43 4
65
M12x1
M18x1
M12x1
M18x1
Ø8
12 18 43 4
15
Ø10.5
12 18 43 4
65 65
5
12 43 4 ■ M12 plug cable exit – Option E ■ M12 metal plug exit – Option H
(SS*/**-*E model) (SS*/**-1H model)
■ Right angle cable exit with sheath gripping tang
Option D (SS*/**-*D model)
Red LED showing the output state; SSE and SSU models equipped with LED showing the presence of power supply.
Cable: ø4.7mm, 2m length, 0.34mm2 conductor section, PVC material.
SS
Characteristic curves
100
■ Excess gain 15
■ Parallel displacement ■ Distance/target size ■ Excess gain ■ Parallel displacement
120 100
Gain factor
Distance Y (mm)
Gain
Distance Y (mm)
100 15 120 100 20
10 110
15
10 110
10 5 100 10
10
10 5 100 10
0 90 5
0 90 0
1 -5 80 1
White paper -5
1 -5 80 a 1
X white
-10 70 -10
a a matt
X white
paper
-10 70
Y a matt -15
,1 -15 60 paper 0,1 Black paper
0 50 100 150 0 20 40 Y 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 120 140
,1 -15 60 0,1 -20
0 50 100 150 0 20 40 60 80 100
SS2
SS2
SS2
SS3
SS3
0 20 40 60 80 100 0 20 40 60 80 100 120 140 0 20 40 60 80 100
Distance (mm) Set distance X (mm) Target dimensions a x a (mm) Distance (mm) Distance X (mm)
■ Distance/target size ■ Trimmer linearity ■ Excess gain ■ Parallel displacement ■ Distance/target size
120 120
120 100 40
Distance Xon (mm)
Gain
Distance Y (mm)
SS3
SS4
SS4
SS4
40 80 120 160 0 0 20 20 40 40 60 60 80 80100 100
Target dimension (mm) Trimmer position (°) Distance (mm) Distance X (mm) Target dimension (mm)
■ Trimmer linearity ■ Excess gain ■ Parallel displacement ■ Excess gain ■ Parallel displacement
Distance Xon (mm)
Gain
Distance Y (mm)
Gain
Distance Y (mm)
250 10 30 15
10
250 10 30 15
10
20 10
200
20 10
200
10 5
150 5
10
150 1 0 0
1
100 1 0 0
1
White paper -10 -5
100
-10 -5
50
-20
X -10
Black paper
50
-20
X -10
Y -15
0 0,1 -30 0,1
SSC
SSC
SSP
SSP
SS4
0 40 80 120 160 200 0 100 200 300 400 0 100 200 300 0 50 100 150 200 250 300
Y 0 100 200 300 400
0 0,1 -30 -15
0,1
0 40 80 Trimmer
120 160 position
200 (°) 0 100 200 Distance
300 400(cm) 0 100 Set distance
200 X300(cm) 0 100 200
Distance
300
(cm)400 0 50 Distance
100 150 X (cm)
200 250 300
Distance Y (mm)
Distance Y (mm)
600 700
100 200 100 10 8
500
600
100 100 0 86
400
500
10 0
-100 64
300
400 Interference Area
-200 2
10 -100 4
SSE-SSR
SSE-SSR
SSE-SSR
SSE-SSR
200
300
1 -300 0
-200 2 -20 100
0 4 8 12 16 20 0 2 4 6 8 10 12 -10 0 10 20
0
200 2 4 6 8 10 12
1 Distance (m) -300 Distance X (m) 0 Angle (°) 100 Distance X (m)
0 4 8 12 16 20 0 2 4 6 8 10 12 -20 -10 0 10 20
0 2 4 6 8 10 12
Distance Y (mm)
Distance Y (mm)
300
16
Operating Area
1000 200 100 300
100 12 200
16
0
100 8
100 12 200
10 100
-100 4
0
8 Interference Area
SSU-SSG
SSU-SSG
SSU-SSG
SSU-SSG
10 0 100
1 -200 0
0 3 6 9 12 -100 0 2 4 6 8 10 12 4 -6 -4 -2 0 2 4 6 0 2 4 6 8 10 12
Distance Y (mm)
Distance Y (mm)
20 70 Operating Area
4
60
100 10
1000 30 5 80
3 50
0 70
20
42 40
10 -10 60
100 10 30
31 50
-20 Interference Area
20
SSU-SSV
SSU-SSV
SSU-SSV
SSU-SSV
0
1 -30 20 10 40
10 0 1 2 3 4 5 -10 0 1 2 3 4 5 -5 -4 -3 -2 -1 0 1 2 3 4 5 0 1 2 3 4 5
30
1 -30 0 10
0 1 2 3 4 5 0 1 2 3 4 5 -5 -4 -3 -2 -1 0 1 2 3 4 5 0 1 2 3 4 5
SS
Accessories
Type Code
Swing mount bracket ST02
Axial mount bracket ST18-A
Right-angle mount bracket ST18-C PRICE
Antidust front ST30 INFORMATION
Right angle beam adapter ST03 AND ORDERING
Shutter STOS*
Protective front ST50
Reflectors see RL leaflet
12
13
2 direct the photoelectric switch to find the optimum position.
16
sensors.
The accessory allows rotation in all
This accessory consists of an internal
5.5
25
30∞
3 clamp the 4 screws
in the defined position
1 fasten the mount optical head of the photoelectric
4.1
tapping screws
ø24
The mirror inside the body is set at
5.5 44 5.5 45° to the optical axes of the sensor
material ABS material ABS allowing detection at 90°.
15° The sensitivity loss is approx. 20-30%.
.2
,,,
,,,
,,,
18
,,,
,,,
18x1 ,,,
,,,
,,,
,,,
,,,
,,,
ø22 ,,,
,,,
70.5
30
14
solvents etc.) 42
18x1 The system consists of a threaded metal
ø24 body, an O-ring and a protection glass.
O-Ring The sensitivity loss is approx. 25%.
protection
glass Right angle mount bracket (ST18-A model)
material anodized aluminium – glass *not for diffuse types
Shutter ø18mm
This accessory, available for through-beam .2
18
36.5
90
ø22
ø24
15° 15°