Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DYNAMIC CONE PENETROMETER TEST (DCPT)

Date of Testing: 28.12.2021

Road Name : MRL-12 Narayanapet to Putpak Via Eklaspur in Narayanapet Dist


1
Test No. :
Section / Chainage
4578M 0
: Zero Reading of DCP :
EKLASPUR TO PUTPAK
Direction : Nanotechnology
Started Test At : Stabilized Base Layer of
150mm

Test Readings
Dynamic Cone
No. of Total No of Penetratio
S.No Penetration Index -
Blows Blows n (mm)
DPI (mm/Blows)
1 0 0 0 -
2 5 5 11 2.20
3 5 10 18 1.40
4 5 15 25 1 40
1.40
5 5 20 36 2.20
6 5 25 43 1.40
7 5 30 52 1.80
8 5 35 62 2.00
9 5 40 69 1.40
10 5 45 77 1.60
11 5 50 83 1.20
12 5 55 95 2.40
13 5 60 104 1.80
14 5 65 112 1.60
15 5 70 126 2.80
16 5 75 134 1.60
17 5 80 146 2.40
Average DPI: 1.83
From above DCP-CBR Relationshi Graph, It is found that for avg DPI value of 1.83 the CBR Value obtained is : >100
For,
DPI = 1.83 => CBR > 100