1 2 3 4 5

62' - 0"

A
0' - 7" 13' - 5 3/4" 0' - 3 1/2" 0' - 3 1/2" 5' - 1" 0' - 3 1/2" 37' - 3 3/4" 0' - 7"

6' - 8 1/8" 6' - 9 5/8" 4' - 1" 2' - 6 1/2" 2' - 6 1/2" 3' - 4 1/4" 3' - 6" 3' - 6" 7' - 0" 11' - 8 3/4" 8' - 2 3/4"

3 3
0' - 7"

1 1

2' - 11 1/4"
2 2

0' - 7"
4' - 2 3/4"
5

RANGE W/ HOOD
MASTER BATH

1'
VENT TO OUTSIDE

-
3

10' - 6 1/2"
MASTER

15
2' - 4 1/4"
9'-0" CLG

/3
BEDROOM

2"
12' - 8 1/4"

MIRROR

1'
KITCHEN

-
9'-0" CLG

10
3

15' - 1"
1/
32
9'-0" CLG
W1 0' - 8 3/8"

"
1' - 10 1/4" 4' - 2 3/4"
1' - 7 5/16" DINING ROOM
9' - 9" 1' - 9 15/16" 3' - 1"
9'-0" CLG

3' - 5 9/16"
W3
3
0' - 5 1/2" 0' - 3 1/2" 0' - 3 1/2" 0' - 3 1/2" 5' - 1"
0' - 6"

0' - 3 1/2"
1
5' - 1 1/8" 3' - 9" 6' - 0 1/2" 1' - 7 1/4" 3' - 5 3/4"

6' - 1"
2' - 5 1/2"

3' - 5 1/4" W.I.C.


3 MIRROR
B
0' - 3 1/2" 5' - 0 1/2"

3' - 11 11/16" 1' - 7 1/4"


BATH S&P
2' - 7"

3
35' - 6"

2' - 1" MIRROR

5' - 10 7/16"
W3 3 3

5' - 6 15/16"
9'-0" CLG MECH. FLUE
CHASE 1' - 7" 7' - 7" PANTRY
LAUNDRY

0' - 5 1/2"
S&P
11' - 0 3/8" BATH W/ SIX
SHELVES
9'-0" CLG
3 9'-0" CLG
4' - 1"

W.I.C.
Linen

1' - 8 1/4" 3' - 8" 1' - 8 1/4"


S&P

S&P

44' - 6"
0' - 3 1/2"
8
W2
0' - 3 1/2"

4' - 1"
0' - 3 1/2"
1' - 10 1/2" 1' - 10 1/2"

Main Level Plan


3 1 1
ENTRY

2' - 0 5/16"
W.I.C. 7

EGDT1100
9'-0" CLG W4
3
- - - -
2' - 9 1/4" 2' - 10 3/4" 2' - 1" 5' - 1"
LIVING ROOM

5' - 5"
5' - 8" 9'-0" CLG
11' - 5 1/4"

3' - 7" 3' - 7" W1


0' - 3 1/2" W2

7' - 5 1/2"
1 GARAGE
2
BEDROOM 2

21' - 11 1/16"
NOTE: 5/8" TYPE "X" GYP
BOARD TO BE USED
9'-0" CLG

19' - 10 3/4"
THROUGHOUT GARAGE
BEDROOM 1
6' - 0"

1 9'-0" CLG
0' - 7"

2' - 0"

1
C

13' - 0"

PROJECT TITLE:

SHEET TITLE:
0' - 7"
18

5' - 8 1/2" 5' - 8 1/2" 5' - 5" 5' - 5" 2' - 3 3/4" 8' - 3 3/4" 5' - 4 1/2" 10' - 5" 10' - 5"
GENERAL NOTES REV. # DESCRIPTION DATE

11' - 5" 10' - 10" 20' - 10"


1. IT IS THE RESPONSIBILTY OF THE GENERAL CONTRACTOR TO INSURE
0' - 7" 12' - 0" 0' - 7" 12' - 0" 0' - 7" 16' - 0" 0' - 7" 22' - 0" 0' - 7" THAT ALL PRODUCTS ARE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS.
62' - 0" 2. IT IS THE OWNER OR CONTRACTORS RESPONSIBILTY TO TAKE
NECESSARY PRECAUTIONS TO PREVENT AGAINST THE BUILD-UP OF
MOISTURE OR MOLD.
3. CONSTRUCTION MATERIALS REFERENCED HEREIN ARE FOR EXAMPLE
PURPOSES ONLY AND MAY NOT COMPLY WITH LOCAL ZONING OR
SAFETY REGULATIONS. OWNER OR CONTRACTOR SHALL BE
RESPONSIBLE FOR THE FINAL CHOICE AND SELECTION OF ALL
PROJECT #: Project Number
CONSTRUCTION MATERIALS. DATE: Issue Date
4. ALL PENETRATIONS IN TOP OR BOTTOM PLATES FOR PLUMBING OR DRAWN BY: Author
D ELECTRICAL RUNS ARE TO BE SEALED. SEE SHEET 001 FOR ADDITIONAL CHECKED BY: Checker
SPECIFICATIONS.
5. PROVIDE 1/2” WATERPROOF GYPSUM BOARD AROUND ALL TUBS, SCALE: As indicated
SHOWERS, AND SPAS.
6. VENT DRYER AND ALL FANS TO OUTSIDE AIR THROUGH VENT WITH
-
DAMPER.
-
7. USE TEMPERED GLASS IN LOCATIONS WHERE REQUIRED BY CODE.
8. ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE.

A1
9. SEE SHEETS SXXX & SXXX FOR STRUCTURAL DETAILS

1 1 Main Level A101 - NOTE


1/4" = 1'-0" 12" = 1'-0"

1 2 3 4 5
1 2 3 4 5

GFI
WP ELECTRICAL SYMBOLS LEGEND
P
3 3 3 3
+44" SINGLE-POLE SWITCH
GD +44"
DW GFCI GFCI
3 THREE-WAY SWITCH

P
TO FAN
R
+44" CEILING-MOUNTED LIGHT FIXTURE
TO FAN GFCI
WALL-MOUNTED LIGHT FIXTURE
+44"
GFI

3
+44"
CEILING FAN
R
GFCI
+44"
GFI DUPLEX OUTLET - 110 VOLTS
+44"
TV CH 220 VOLT OUTLET FOR OVENS,
3
WATER HEATERS, CLOTHES
DRYERS, WELDERS, &CT.
+44"
+44" SMOKE DETECTOR
TO FAN 3 3
GFI
B P PHONE HARD LINE OUTLET

P
3
+44"
GFI PC
PC HARD LINE OUTLET
3

TV
CABLE CONNECTION OUTLET
TO FAN

CH DOORBELL CHIME

3 3
3
PC
GFI R RECCESSED CAN LIGHT

Main Level Electrical


TV
3 WP

SPECIAL OUTLET

EGDT1100
- - - -

3
ELECTRICAL NOTES
3 On Ceiling
BUZZER GFI 1. ELECTRICAL PLANS ARE FOR LAYOUT PURPOSES ONLY. CONSULT WITH
WP A LICENSED ELECTRICIAN FOR EXACT SPECIFICATIONS TO MEET LOCAL
& GOVERNING CODES.
2. WORK IS TO COMPLY WITH ALL CODES AND ORDINANCES.
3. ALL OUTLETS ARE TO BE +44” ABOVE FLOOR LINE IN THE FOLLOWING
AREAS: PANTRY, BATHROOMS AND KITCHENS ABOVE COUNTER TOPS,
AND GARAGES.
C 4. GROUND FAULT INTERRUPT (GFI) OUTLETS ARE REQUIRED IN THE
FOLLOWING LOCATIONS: BATHROOMS, GARAGES, EXTERIOR WALLS,
SEE A100 (BASEMENT) FOR CIRCUT BREAKERS UNFINISHED AREAS, KITCHEN ISLAND, AND WITHIN 5’-0” OF SINKS.
5. PROVIDE A SEPARATE CIRCUIT FOR MICROWAVE OVEN.
6. PROVIDE A SEPARATE CIRCUIT FOR OUTLETS IN KITCHEN ISLAND.

PROJECT TITLE:
7. ALL EXTERIOR OUTLETS SHALL BE ENCLOSED IN A WEATHERPROOF

SHEET TITLE:
PROTECTIVE COVER.
8. EXTERIOR SPOTLIGHTS TO BE ON PHOTOELECTRIC CELL WITH TIMER
9. ALL RECESSED LIGHTS IN EXTERIOR CEILINGS TO BE INSULTION COVER
RATED.
10.ELECTRICAL OUTLET PLATE GASKETS SHALL BE INSULATED ON
RECEPTACLE, SWITCH, AND ANY OTHER BOXES IN EXTERIOR WALL.
REV. # DESCRIPTION DATE
11.VERIFY ALL ELECTRICAL LOCATIONS WITH OWNER.
12.CONSULT OWNER FOR EXACT PLACEMENT OF BOXES FOR
AUDIO/VISUAL EQUIPMENT.
13.CABINET LIGHTING IS TO BE SWITCHED AND INCLUDES LIGHTING INSIDE
AND UNDERNEATH UPPER CABINETS. VERIFY WITH OWNER.
14.BRACE LIGHT FIXTURES IN BEDROOMS, GREAT ROOMS, FAMILY/LIVING
ROOMS, DENS, MUSIC ROOMS, ETC. FOR CEILING FANS.
15.VERIFY THAT PANEL IS SIZED LARGE ENOUGH FOR ADDITION. INSTALL
ADDITIONAL SUB PANEL AS REQUIRED. DESIGN BUILD BY ELECTRICAL
CONTRACTOR.
16.CONTRACTOR TO INSTALL OWNER SPECIFIED FIXTURES.
PROJECT #: Project Number
DATE: Issue Date
DRAWN BY: Author
D CHECKED BY: Checker
SCALE: As indicated

1
2 Main Level Electrical
1/4" = 1'-0"
E1
1 2 3 4 5

E101 - NOTES
12" = 1'-0"