Professional Documents
Culture Documents
Siemens TIA
Siemens TIA
Siemens TIA
SIMATIC
Products for
Totally Integrated
Automation
Catalog Edition
ST 70 2021 siemens.com/tia
© Siemens 2021
Related catalogs
SIMATIC HMI / ST 80/ST PC SITRAIN
PC-based Automation Digital Industry Academy
Human Machine Interface Systems
PC-based Automation
E86060-K4678-A111-C7-7600 www.siemens.com/tst
E86060-D4001-A510-D9 www.siemens.com/automation-contact
© Siemens 2021
Components can be selected, Intelligent selection wizards Required modules, devices and Time savings of 80% in design –
configured and ordered quickly, check the compatibility of the networks are automatically thanks to ease of use and
easily and securely from the configured components and generated and clearly compared intelligent support
Siemens automation portfolio enable error-free ordering to one another
Siemens ST 70 · 2021 1
© Siemens 2021
2 Siemens ST 70 · 2021
© Siemens 2021
Digital Enterprise
The building blocks that ensure
everything works together
perfectly in the digital enterprise
Digitalization is already changing all areas of life and existing
business models. It is placing greater pressure on industry
while at the same time creating new business opportunities.
Today, thanks to scalable solutions from Siemens, companies
can already become a digital enterprise and ensure their
competitiveness.
Today manufacturers Consumers want cus- To ensure a high level of Today the product itself Increasing networking
have to bring products to tomized products, but at quality while meeting needs to be sustainable escalates the threat to
market at an ever-increas- a price they would pay legal requirements, and environmentally production facilities
ing pace despite the for a mass-produced companies have to friendly, while energy of cyberattacks. Today
growing complexity of item. That only works establish closed quality efficiency in production more than ever, com-
these products. In the if production is more loops and enable the has become a competi- panies need suitable
past, a major manufac- flexible than ever traceability of products. tive advantage. security measures.
turer would push aside a before.
small one, but now it is a
fast manufacturer that
overtakes a slow one.
4 Siemens ST 70 · 2021
© Siemens 2021
Siemens ST 70 · 2021 5
© Siemens 2021
6 Siemens ST 70 · 2021
1
© Siemens 2021
Introduction
Siemens ST 70 · 2021
© Siemens 2021
2/2 Introduction
2/35 LOGO!Power
2/35 Introduction
2/36 1-phase, 5 V DC
2/39 1-phase, 12 V DC
2/42 1-phase, 15 V DC
2/45 1-phase, 24 V DC
Siemens ST 70 · 2021
© Siemens 2021
■ Overview
• The space-saving basic variants
• Interface for the connection of expansion modules,
up to 24 digital inputs, 20 digital outputs, 8 analog inputs
2
and 8 analog outputs can be addressed
• All basic units with integrated web server
• Enclosure width 72 mm (4 MW)
• All basic units with Ethernet interface for communication with
LOGO! 8, LOGO! TDE, SIMATIC Controllers, SIMATIC Panels
and PCs
• Use of standard micro CF cards
■ Technical specifications
2
Article number 6ED1052-1CC08-0BA1 6ED1052-1MD08-0BA1 6ED1052-1HB08-0BA1 6ED1052-1FB08-0BA1
LOGO! 24CE, LOGO!12/24RCE, LOGO! 24RCE, LOGO!230RCE,
8DI(4AI)/4DO, 400 Blocks 8DI(4AI)/4DO, 400 Blocks 8DI/4DO, 400 Blocks 8DI/4DO, 400 Blocks
Display
with display Yes Yes Yes Yes
Installation type/mounting
Mounting on 35 mm DIN rail, on 35 mm DIN rail, on 35 mm DIN rail, on 35 mm DIN rail,
4 spacing units wide 4 spacing units wide 4 spacing units wide 4 spacing units wide
Supply voltage
Rated value (DC)
• 12 V DC Yes
• 24 V DC Yes Yes Yes
• 115 V DC Yes
• 230 V DC Yes; 240 V DC
Rated value (AC)
• 24 V AC Yes
• 115 V AC Yes
• 230 V AC Yes; 240 V AC
Time of day
Time switching clocks
• Number 400; Max. 400, 400; Max. 400, 400; Max. 400, 400; Max. 400,
function-specific function-specific function-specific function-specific
• Power reserve 480 h 480 h 480 h 480 h
Digital inputs
Number of digital inputs 8; Of which 4 can be used in 8; Of which 4 can be used in 8 8
analog mode (0 to 10 V) analog mode (0 to 10 V)
Digital outputs
Number of digital outputs 4; Transistor 4; Relays 4; Relays 4; Relays
Short-circuit protection Yes; electrical (1 A) No; external fusing No; external fusing No; external fusing
necessary necessary necessary
Output current
• for signal "1" permissible range 0.3 A 10 A
for 0 to 55 °C, max.
Relay outputs
Switching capacity of contacts
- with inductive load, max. 3A 3A 3A
- with resistive load, max. 10 A 10 A 10 A
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class B, Yes; Radio interference Yes; Radio interference Yes; Radio interference Yes; Radio interference
for use in residential areas suppression according to suppression according to suppression according to suppression according to
EN55011, EN55011, EN55011, EN55011,
Limit Value Class B Limit Value Class B Limit Value Class B Limit Value Class B
Standards, approvals, certificates
CE mark Yes Yes Yes Yes
CSA approval Yes Yes Yes Yes
UL approval Yes Yes Yes Yes
FM approval Yes Yes Yes Yes
developed in acc. with IEC 61131 Yes Yes Yes Yes
according to VDE 0631 Yes Yes Yes Yes
Marine approval Yes Yes Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -20 °C; No condensation -20 °C; No condensation -20 °C; No condensation -20 °C; No condensation
• max. 55 °C 55 °C 55 °C 55 °C
Altitude during operation
relating to sea level
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 080 hPa ... 795 hPa 1 080 hPa ... 795 hPa 1 080 hPa ... 795 hPa 1 080 hPa ... 795 hPa
(-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Dimensions
Width 71.5 mm 71.5 mm 71.5 mm 71.5 mm
Height 90 mm 90 mm 90 mm 90 mm
Depth 60 mm 60 mm 60 mm 60 mm
■ Overview
• Basic variants optimized for costs
• Interface for the connection of expansion modules,
up to 24 digital inputs, 20 digital outputs, 8 analog inputs
2
and 8 analog outputs can be addressed
• With connection option for LOGO! TDE text display
• All basic units with integrated web server
• Enclosure width 72 mm (4 MW)
• All basic units with Ethernet interface for communication with
LOGO! 8, LOGO! TDE, SIMATIC Controllers, SIMATIC Panels
and PCs
• Use of standard micro CF cards
■ Technical specifications
2
Article number 6ED1052-2CC08-0BA1 6ED1052-2MD08-0BA1 6ED1052-2HB08-0BA1 6ED1052-2FB08-0BA1
LOGO! 24CEo, LOGO!12/24RCEO, LOGO! 24RCEO, 8DI/4DO, LOGO!230RCEo, 8DI/4DO,
8DI(4AI)/4DO, 8DI(4AI)/4DO, 400 Blocks 400 Blocks 400 Blocks
400 Blocks
Installation type/mounting
Mounting on 35 mm DIN rail, on 35 mm DIN rail, on 35 mm DIN rail, 4 spacing on 35 mm DIN rail,
4 spacing units wide 4 spacing units wide units wide 4 spacing units wide
Supply voltage
Rated value (DC)
• 12 V DC Yes
• 24 V DC Yes Yes Yes
• 115 V DC Yes
• 230 V DC Yes; 240 V DC
Rated value (AC) Yes
• 115 V AC Yes
• 230 V AC Yes; 240 V AC
Time of day
Time switching clocks
• Number 400; Max. 400, 400; Max. 400, 400; Max. 400, 400; Max. 400,
function-specific function-specific function-specific function-specific
• Power reserve 480 h 480 h 480 h
Digital inputs
Number of digital inputs 8; Of which 4 can be used 8; Of which 4 can be used 8 8
in analog mode (0 to 10 V) in analog mode (0 to 10 V)
Digital outputs
Number of digital outputs 4; Transistor 4; Relays 4; Relays 4; Relays
Short-circuit protection Yes; electrical (1 A) No; external fusing No; external fusing No; external fusing
necessary necessary necessary
Output current
• for signal "1" permissible range 0.3 A 10 A
for 0 to 55 °C, max.
Relay outputs
Switching capacity of contacts
- with inductive load, max. 3A 3A 3A
- with resistive load, max. 10 A 10 A 10 A
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class B, Yes; Radio interference Yes; Radio interference Yes; Radio interference Yes; Radio interference
for use in residential areas suppression according to suppression according to suppression according to suppression according to
EN55011, EN55011, EN55011, EN55011,
Limit Value Class B Limit Value Class B Limit Value Class B Limit Value Class B
Standards, approvals, certificates
CE mark Yes Yes Yes Yes
CSA approval Yes Yes Yes Yes
UL approval Yes Yes Yes Yes
FM approval Yes Yes Yes Yes
developed in accordance Yes Yes Yes Yes
with IEC 61131
according to VDE 0631 Yes Yes Yes Yes
Marine approval Yes Yes Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -20 °C; No condensation -20 °C; No condensation -20 °C; No condensation -20 °C; No condensation
• max. 55 °C 55 °C 55 °C 55 °C
Altitude during operation
relating to sea level
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 080 hPa ... 795 hPa 1 080 hPa ... 795 hPa (-1 000 1 080 hPa ... 795 hPa 1 080 hPa ... 795 hPa
(-1 000 m ... +2 000 m) m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Dimensions
Width 71.5 mm 71.5 mm 71.5 mm 71.5 mm
Height 90 mm 90 mm 90 mm 90 mm
Depth 60 mm 60 mm 60 mm 60 mm
■ Overview
• Expansion modules for connection to LOGO! Modular
• With digital inputs and outputs, analog inputs,
or analog outputs
2
■ Technical specifications
2
Article number 6ED1055-1CB00-0BA2 6ED1055-1HB00-0BA2 6ED1055-1MB00-0BA2 6ED1055-1FB00-0BA2
LOGO! DM8 24 Exp. mod., LOGO! DM8 24R Exp. mod. LOGO! DM8 12/24R LOGO! DM8 230R Exp. mod.
4DI/4DO 2 MW, 4DI/4DO Exp. mod. 2 MW, 4DI/DO 2 MW, 4DI/4DO
Installation type/mounting
Mounting on 35 mm DIN rail, on 35 mm DIN rail, on 35 mm DIN rail, on 35 mm DIN rail,
2 spacing units wide 2 spacing units wide 2 spacing units wide 2 spacing units wide
Supply voltage
Rated value (DC)
• 12 V DC Yes
• 24 V DC Yes Yes Yes
• 115 V DC Yes
• 230 V DC Yes
Rated value (AC)
• 24 V AC Yes
• 115 V AC Yes
• 230 V AC Yes
Line frequency
• permissible range, lower limit 47 Hz 47 Hz
• permissible range, upper limit 63 Hz 63 Hz
Digital inputs
Number of digital inputs 4 4 4 4
Input voltage
• Type of input voltage DC AC/DC DC AC/DC
• for signal "0" < 5 V DC < 5 V AC/DC < 5 V DC < 40 V AC, < 30 V DC
• for signal "1" > 12 V DC > 12 V AC/DC > 8.5 V > 79 V AC, > 79 V DC
Input current
• for signal "0", max. 0.88 mA 1.1 mA 0.88 mA 0.06 mA; 0.05 mA with AC,
(permissible quiescent current) 0.06 mA with DC
• for signal "1", typ. 2.1 mA 2.63 mA 1.5 mA 0.13 mA
Input delay
(for rated value of input voltage)
for standard inputs
- at "0" to "1", max. 1.5 ms 1.5 ms 1.5 ms 40 ms
- at "1" to "0", max. 1.5 ms 15 ms 1.5 ms 75 ms
Digital outputs
Number of digital outputs 4 4; Relays 4; Relays 4; Relays
Short-circuit protection Yes No No No
Controlling a digital input Yes Yes Yes
Switching capacity of the outputs
• on lamp load, max. 1 000 W 1 000 W 1 000 W; 500 W at 115V AC
Parallel switching of two outputs
• for uprating No No No No
Switching frequency
• with resistive load, max. 10 Hz 2 Hz 2 Hz 2 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz
• mechanical, max. 10 Hz 10 Hz 10 Hz
Relay outputs
Switching capacity of contacts
- with inductive load, max. 3A 3A 3A
- with resistive load, max. 5A 5A 5A
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class B, Yes Yes Yes Yes
for use in residential areas
■ Technical specifications
2
Article number 6ED1055-1CB00-0BA2 6ED1055-1HB00-0BA2 6ED1055-1MB00-0BA2 6ED1055-1FB00-0BA2
LOGO! DM8 24 Exp. mod., LOGO! DM8 24R Exp. mod. LOGO! DM8 12/24R LOGO! DM8 230R Exp. mod.
4DI/4DO 2 MW, 4DI/4DO Exp. mod. 2 MW, 4DI/DO 2 MW, 4DI/4DO
Standards, approvals, certificates
CE mark Yes Yes Yes Yes
CSA approval Yes Yes Yes Yes
UL approval Yes Yes Yes Yes
FM approval Yes Yes Yes Yes
developed in accordance Yes Yes Yes Yes
with IEC 61131
according to VDE 0631 Yes Yes Yes
Marine approval Yes Yes Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. 0 °C; ES03 and higher: 0 °C; ES03 and higher: 0 °C; ES03 and higher: 0 °C; ES03 and higher:
-20 °C -20 °C -20 °C -20 °C
• max. 55 °C 55 °C 55 °C 55 °C
Dimensions
Width 35.5 mm 35.5 mm 35.5 mm 35.5 mm
Height 90 mm 90 mm 90 mm 90 mm
Depth 58 mm 58 mm 58 mm 58 mm
■ Technical specifications
2
Article number 6ED1055-1CB10-0BA2 6ED1055-1NB10-0BA2 6ED1055-1FB10-0BA2
LOGO! DM16 24 Exp. mod., 4 MW, LOGO! DM16 24R Exp. mod. 4 MW, LOGO! DM16 230R Exp. mod. 4 MW,
8DI/8DO 8DI/8DO 8DI/8DO
Digital outputs
Number of digital outputs 8 8; Relays 8; Relays
Short-circuit protection Yes No No
Controlling a digital input Yes Yes
Switching capacity of the outputs
• on lamp load, max. 1 000 W 1 000 W; 500 W at 115V AC
Parallel switching of two outputs
• for uprating No No No
Switching frequency
• with resistive load, max. 10 Hz 2 Hz 2 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz
• mechanical, max. 10 Hz 10 Hz
Relay outputs
Switching capacity of contacts
- with inductive load, max. 3A 3A
- with resistive load, max. 5A 5A
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class B, Yes Yes Yes
for use in residential areas
Standards, approvals, certificates
CE mark Yes Yes Yes
CSA approval Yes Yes Yes
UL approval Yes Yes Yes
FM approval Yes Yes Yes
developed in accordance Yes Yes Yes
with IEC 61131
according to VDE 0631 Yes Yes Yes
Marine approval Yes Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. 0 °C; ES03 and higher: -20 °C 0 °C; ES03 and higher: -20 °C 0 °C; ES03 and higher: -20 °C
• max. 55 °C 55 °C 55 °C
Dimensions
Width 71.5 mm 71.5 mm 71.5 mm
Height 90 mm 90 mm 90 mm
Depth 58 mm 58 mm 58 mm
■ Technical specifications
2
Article number 6ED1055-1MA00-0BA2 6ED1055-1MD00-0BA2
LOGO! AM2 Exp. mod., 12/24V, 2AI, LOGO! AM2 RTD, 2AI, -50..+200DECR/C
Installation type/mounting
Mounting on 35 mm DIN rail, 2 spacing units wide on 35 mm DIN rail, 2 spacing units wide
Supply voltage
Rated value (DC)
• 12 V DC Yes; 10.8 V DC to 28.8 V DC Yes; 10.8 V DC to 28.8 V DC
• 24 V DC Yes; 10.8 V DC to 28.8 V DC Yes; 10.8 V DC to 28.8 V DC
Analog inputs
Number of analog inputs 2 2; 2 or 3 wire connection
Input ranges
• Voltage Yes No
• Current Yes No
• Resistance thermometer No Yes; For PT100/PT1000 sensors
Input ranges (rated values),
voltages
• 0 to +10 V Yes No
Input ranges (rated values),
currents
• 0 to 20 mA Yes; 0 mA or 4 mA to 20 mA No
Input ranges (rated values),
resistance thermometer
• Pt 100 No Yes
EMC
Emission of radio interference
acc. to EN 55 011
• Limit class B, Yes Yes
for use in residential areas
Standards, approvals, certificates
CE mark Yes Yes
CSA approval Yes Yes
UL approval Yes Yes
FM approval Yes Yes
developed in accordance Yes Yes
with IEC 61131
according to VDE 0631 Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. 0 °C; ES03 and higher: -20 °C 0 °C; ES03 and higher: -20 °C
• max. 55 °C 55 °C
Dimensions
Width 35.5 mm 35.5 mm
Height 90 mm 90 mm
Depth 58 mm 58 mm
■ Technical specifications
2
Article number 6ED1055-1MM00-0BA2 Article number 6ED1055-1MM00-0BA2
LOGO! AM2 AQ, 2AQ, 0-10V, LOGO! AM2 AQ, 2AQ, 0-10V,
0/4-20mA 0/4-20mA
Installation type/mounting Standards, approvals, certificates
Mounting on 35 mm DIN rail, CE mark Yes
2 spacing units wide CSA approval Yes
Supply voltage UL approval Yes
Rated value (DC) 24 V FM approval Yes
Analog outputs developed in accordance Yes
Number of analog outputs 2 with IEC 61131
Output ranges, voltage according to VDE 0631 Yes
• 0 to 10 V Yes Marine approval Yes
Output ranges, current Ambient conditions
• 0 to 20 mA Yes Ambient temperature
• 4 mA to 20 mA Yes during operation
EMC • min. 0 °C; ES03 and higher: -20 °C
Emission of radio interference • max. 55 °C
acc. to EN 55 011 Dimensions
• Limit class B, Yes Width 35.5 mm
for use in residential areas Height 90 mm
Depth 58 mm
2
SIPLUS LOGO! 8 logic module
SIPLUS LOGO! 24CE
24 V DC supply voltage,
8 digital inputs 24 V DC,
of which 4 can be used
in analog mode (0 to 10 V),
4 digital outputs 24 V DC, 0.3 A,
integrated time switch
Ethernet interface;
400 function blocks
can be interlinked,
modular expansion capability
Extended temperature range and 6AG1052-1CC08-7BA1
exposure to media
SIPLUS LOGO! 12/24RCE
12...24 V DC supply voltage,
8 digital inputs 12/24 V DC,
of which 4 can be used
in analog mode (0 to 10 V),
4 relay outputs 10 A,
integrated time switch,
• The space-saving basic variants Ethernet interface;
• Interface for connecting expansion modules, 400 function blocks
up to 24 digital inputs, 20 (16) digital outputs, 8 analog inputs can be interlinked,
modular expansion capability
and 8 (2) analog outputs can be addressed
Extended temperature range and 6AG1052-1MD08-7BA1
• With connection option for LOGO! TD text display (can be exposure to media
connected to all LOGO! 0BA6 and 0BA7 basic variants);
LOGO! TDE can be connected to LOGO! 8 or higher SIPLUS LOGO! 24RCE
24 V AC/DC supply voltage,
New for LOGO! 8 8 digital inputs 24 V AC/DC,
• All basic units with integrated web server 4 relay outputs 10 A,
integrated time switch,
• Same enclosure width as LOGO! 0BA6 (4 MW) Ethernet interface;
• All basic units with Ethernet interface for communication 400 function blocks
can be interlinked,
with LOGO!, SIMATIC Controllers, SIMATIC Panel and PC modular expansion capability
• Use of standard micro CF cards Extended temperature range and 6AG1052-1HB08-7BA1
exposure to media
LOGO! 0BA7 versions:
SIPLUS LOGO! 230RCE
• Ethernet interface for communication with
SIMATIC Controllers, SIMATIC Panel and PC 115...230 V AC/DC supply voltage,
8 digital inputs 115...230 V AC/DC,
• Networking of max. 8 LOGO! devices 4 relay outputs 10 A,
• Use of standard SD card or SIMATIC Memory Card integrated time switch,
Ethernet interface;
Note: 400 function blocks
can be interlinked,
SIPLUS LOGO! 6/7 versions are not compatible with modular expansion capability
SIPLUS LOGO! 8. Extended temperature range and 6AG1052-1FB08-7BA1
SIPLUS extreme products are based on SIMATIC standard exposure to media
products. The contents listed here were taken from the Accessories
corresponding standard products. SIPLUS extreme-specific SIPLUS LOGO! TDE 6AG1055-4MH08-2BA1
information was added.
(Extended temperature range
-25 ... +60 °C (start-up -20 °C)
and exposure to media)
6-line text display, can be
connected to all LOGO! 8 variants
with and without display,
with 2 Ethernet interfaces;
incl. installation accessories.
Requires additional 12 V DC or
24 V AC/DC power supply
LOGO!Soft Comfort V8 6ED1058-0BA08-0YA1
For programming on the PC
in LAD/FBD;
executes on Windows 8, 7, XP,
Linux and Mac OSX; on DVD
Front panel mounting set 6AG1057-1AA00-0AA2
Width 8 MW, with keys
■ Technical specifications
2
Article number 6AG1052-1CC08-7BA1 6AG1052-1MD08-7BA1 6AG1052-1FB08-7BA1 6AG1052-1HB08-7BA1
Based on 6ED1052-1CC08-0BA1 6ED1052-1MD08-70BA1 6ED1052-1HB08-0BA1 6ED1052-1FB08-0BA1
SIPLUS LOGO! 24CE SIPLUS LOGO! 12/24RCE SIPLUS LOGO! 230RCE SIPLUS LOGO! 24RCE
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin; -25 °C; = Tmin; -25 °C; = Tmin; -25 °C; = Tmin;
Startup @ -20 °C Startup @ -20 °C Startup @ -20 °C Startup @ -20 °C
• max. 60 °C; = Tmax 60 °C; Tmax; Tmax > +55 °C 60 °C; Tmax; Tmax > +55 °C 70 °C; Tmax; Tmax > +55 °C
max. load 1 A per relay or max. load 1 A per relay max. load 1 A per relay or
max. load 3 A per relay and max. load 3 A per relay
half the number of DIs and half the number of DIs
(no adjacent points) (no adjacent points)
• At cold restart, min. -20 °C; incl. condensation / -20 °C; incl. condensation / -20 °C; incl. condensation / -20 °C; incl. condensation /
frost permitted frost permitted frost permitted frost permitted
(no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 2 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K)
at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K) at
at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; 100 %; 100 %; 100 %;
tested in accordance RH incl. condensation / frost RH incl. condensation / frost RH incl. condensation / frost RH incl. condensation / frost
with IEC 60068-2-38, max. (no commissioning in (no commissioning in (no commissioning in (no commissioning in
bedewed state), horizontal bedewed state), horizontal bedewed state), horizontal bedewed state), horizontal
installation installation installation installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and Yes; Incl. diesel and Yes; Incl. diesel and Yes; Incl. diesel and
available coolants and lubricants oil droplets in the air oil droplets in the air oil droplets in the air oil droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
2
Article number 6AG1052-1CC08-7BA1 6AG1052-1MD08-7BA1 6AG1052-1FB08-7BA1 6AG1052-1HB08-7BA1
Based on 6ED1052-1CC08-0BA1 6ED1052-1MD08-70BA1 6ED1052-1HB08-0BA1 6ED1052-1FB08-0BA1
SIPLUS LOGO! 24CE SIPLUS LOGO! 12/24RCE SIPLUS LOGO! 230RCE SIPLUS LOGO! 24RCE
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt
spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
of environmental conditions must remain in place over must remain in place over must remain in place over must remain in place over
acc. to EN 60721, EN 60654-4 the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
and ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 Yes; Class 2 Yes; Class 2 Yes; Class 2
assemblies acc. to EN 61086 for high reliability for high reliability for high reliability for high reliability
• Protection against fouling Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
acc. to EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
2
SIPLUS LOGO! 8 logic module
SIPLUS LOGO! 24CEo
24 V DC supply voltage
8 digital inputs 24 V DC,
of which 4 can be used
in analog mode (0 to 10 V)
4 digital outputs 24 V DC, 0.3 A,
Integrated time switch
Ethernet interface;
without display and keyboard
400 function blocks
can be interlinked,
modular expansion capability
Extended temperature range and 6AG1052-2CC08-7BA1
exposure to media
SIPLUS LOGO! 230RCEo
115...230 V AC/DC supply voltage
8 digital inputs 115...230 V AC/DC
4 relay outputs 10 A
Integrated time switch
Ethernet interface;
• Basic variants optimized for costs without display or keyboard
• Interface for connecting expansion modules, 400 function blocks
up to 24 digital inputs, 16 (20) digital outputs, 8 analog inputs can be interlinked,
modular expansion capability
and 2 (8) analog outputs can be addressed
Extended temperature range and 6AG1052-2FB08-7BA1
• With connection option for LOGO! TD text display exposure to media
(can be connected to all LOGO! 0BA6 basic variants)
SIPLUS LOGO! 24RCEo
New for SIPLUS LOGO! 8 24 V AC/DC supply voltage,
• All basic units with integrated web server 8 digital inputs 24 V AC/DC,
4 relay outputs 10 A,
• Same enclosure width as LOGO! 0BA6 (4 MW) integrated time switch,
• All basic units with Ethernet interface for communication Ethernet interface;
with LOGO!, SIMATIC Controllers, SIMATIC Panel and PC without display or keyboard;
400 function blocks
• Use of standard micro CF cards can be interlinked,
modular expansion capability
Note:
Extended temperature range and 6AG1052-2HB08-7BA1
SIPLUS LOGO! 6 versions are not compatible with exposure to media
SIPLUS LOGO! 8. SIPLUS LOGO! 12/24RCEo
SIPLUS extreme products are based on SIMATIC standard 12...24 V DC supply voltage
products. The contents listed here were taken from the 8 digital inputs 12...24 V DC,
respective standard products. SIPLUS extreme-specific of which 4 can be used
in analog mode (0 to 10 V)
information was added. 4 relay outputs 10 A
Integrated time switch
Ethernet interface;
without display and keyboard
400 function blocks
can be interlinked,
modular expansion capability
Extended temperature range and 6AG1052-2MD08-7BA1
exposure to media
Accessories
SIPLUS LOGO! TDE 6AG1055-4MH08-2BA1
(Extended temperature range
-25 ... +60 °C (start-up -20 °C)
and exposure to media)
6-line text display, can be
connected to all LOGO! 8 variants
with and without display,
with 2 Ethernet interfaces;
incl. installation accessories.
Requires additional 12 V DC or
24 V AC/DC power supply
LOGO!Soft Comfort V8 6ED1058-0BA08-0YA1
For programming on the PC
in LAD/FBD;
executes on Windows 8, 7, XP,
Linux and Mac OSX; on DVD
Front panel mounting set
Width 8 MW, with keys 6AG1057-1AA00-0AA2
■ Technical specifications
2
Article number 6AG1052-1CC08-7BA1 6AG1052-1MD08-7BA1 6AG1052-1HB08-7BA1 6AG1052-1FB08-7BA1
Based on 6ED1052-2CC08-0BA1 6ED1052-2MD08-0BA1 6ED1052-2HB08-0BA1 6ED1052-2FB08-0BA1
SIPLUS LOGO! 24CE SIPLUS LOGO! 12/24RCE SIPLUS LOGO! 24RCE SIPLUS LOGO! 230RCE
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin; -25 °C; = Tmin; -25 °C; = Tmin; -25 °C; = Tmin;
Startup @ -20 °C Startup @ -20 °C Startup @ -20 °C Startup @ -20 °C
• max. 60 °C; = Tmax 60 °C; Tmax; Tmax > +55 °C 70 °C; Tmax; Tmax > +55 °C 60 °C; Tmax; Tmax > +55 °C
max. load 1 A per relay or max. load 1 A per relay or max. load 1 A per relay
max. load 3 A per relay and max. load 3 A per relay and
half the number of DIs half the number of DIs
(no adjacent points) (no adjacent points)
• At cold restart, min. -20 °C; incl. condensation / -20 °C; incl. condensation / -20 °C; incl. condensation / -20 °C; incl. condensation /
frost permitted frost permitted frost permitted frost permitted
(no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 2 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m)
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; 100 %; 100 %; 100 %;
tested in accordance RH incl. condensation / frost RH incl. condensation / frost RH incl. condensation / frost RH incl. condensation / frost
with IEC 60068-2-38, max. (no commissioning in (no commissioning in (no commissioning in (no commissioning in
bedewed state), horizontal bedewed state), horizontal bedewed state), horizontal bedewed state), horizontal
installation installation installation installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil drop- Yes; Incl. diesel and oil drop- Yes; Incl. diesel and oil drop- Yes; Incl. diesel and oil drop-
available coolants and lubricants lets in the air lets in the air lets in the air lets in the air
Use in stationary industrial
systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
2
Article number 6AG1052-1CC08-7BA1 6AG1052-1MD08-7BA1 6AG1052-1HB08-7BA1 6AG1052-1FB08-7BA1
Based on 6ED1052-2CC08-0BA1 6ED1052-2MD08-0BA1 6ED1052-2HB08-0BA1 6ED1052-2FB08-0BA1
SIPLUS LOGO! 24CE SIPLUS LOGO! 12/24RCE SIPLUS LOGO! 24RCE SIPLUS LOGO! 230RCE
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt
spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil)
Remark
- Note regarding classificatio * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
n of environmental conditions must remain in place over must remain in place over must remain in place over must remain in place over
acc. to EN 60721, EN 60654-4 the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
and ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 Yes; Class 2 Yes; Class 2 Yes; Class 2
assemblies acc. to EN 61086 for high reliability for high reliability for high reliability for high reliability
• Protection against fouling Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
acc. to EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
2
SIPLUS LOGO! 8
expansion modules
SIPLUS LOGO! DM8 24
24 V DC supply voltage,
4 digital inputs 24 V DC,
4 digital outputs 24 V DC, 0.3 A
Extended temperature range and 6AG1055-1CB00-7BA2
exposure to media
SIPLUS LOGO! DM8 230R
115...230 V AC/DC supply voltage,
4 digital inputs 115...230 V AC/DC,
4 relay outputs 5 A
Extended temperature range and 6AG1055-1FB00-7BA2
exposure to media
SIPLUS LOGO! DM8 24R
24 V AC/DC supply voltage,
4 digital inputs 24 V AC/DC,
4 relay outputs 5 A
• Expansion modules for connection to LOGO! modular Extended temperature range and 6AG1055-1HB00-7BA2
exposure to media
• With digital inputs and outputs, analog inputs,
or analog outputs SIPLUS LOGO! AM2
12...24 V DC supply voltage,
Note: 2 analog inputs 0 to 10 V or
SIPLUS LOGO! 6 versions are not compatible with 0 to 20 mA, 10-bit resolution
SIPLUS LOGO! 8. Extended temperature range and 6AG1055-1MA00-7BA2
exposure to media
SIPLUS extreme products are based on SIMATIC standard
SIPLUS LOGO! DM8 12/24R
products. The contents listed here were adopted from the
respective standard products. SIPLUS extreme specific 12...24 V DC supply voltage,
information was added. 4 digital inputs 12...24 V DC,
4 relay outputs 5 A
Extended temperature range and 6AG1055-1MB00-7BA2
exposure to media
LOGO! AM2 RTD
12...24 V DC supply voltage,
2 analog inputs Pt100,
temperature range -50 °C to 200 °C
Extended temperature range and 6AG1055-1MD00-7BA2
exposure to media
SIPLUS LOGO! AM2 AQ
24 V DC supply voltage,
2 analog outputs 0 to 10 V,
0/4 to 20 mA
Extended temperature range and 6AG1055-1MM00-7BA2
exposure to media
SIPLUS LOGO! DM16 24R
24 V DC supply voltage,
8 digital inputs 24 V DC,
8 relay outputs 5 A
Extended temperature range and 6AG1055-1NB10-7BA2
exposure to media
Accessories
LOGO!Soft Comfort V8 6ED1058-0BA08-0YA1
For programming on the PC
in LAD/FBD;
executes on Windows 8, 7, XP,
Linux and Mac OSX; on DVD
Front panel mounting set
Width 8 MW, with keys 6AG1057-1AA00-0AA2
■ Technical specifications
2
Article number 6AG1055-1CB00-7BA2 6AG1055-1HB00-7BA2 6AG1055-1MB00-7BA2
Based on 6ED1055-1CB00-0BA2 6ED1055-1HB00-0BA2 6ED1055-1MB00-0BA2
SIPLUS LOGO! DM8 24 V8 SIPLUS LOGO! DM8 24R V8 SIPLUS LOGO! DM8 12/24R V8
Ambient conditions
Ambient temperature
during operation
• min. -40 °C; = Tmin; Startup @ -25 °C -40 °C; = Tmin; Startup @ -25 °C -40 °C; = Tmin; Startup @ -25 °C
• max. 70 °C; Tmax; Tmax > +55 °C max. load 70 °C; = Tmax; Tmax > +55 °C max. 70 °C; = Tmax; Tmax > +55 °C max.
0.2 A per output load 3 A per relay or max. total current load 3 A per relay or max. total current
10 A 10 A
• At cold restart, min. -25 °C; incl. condensation / frost -25 °C; incl. condensation / frost -25 °C; incl. condensation / frost
permitted (no commissioning under permitted (no commissioning under permitted (no commissioning under
condensation conditions) condensation conditions) condensation conditions)
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m)// (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation / frost 100 %; RH incl. condensation / frost 100 %; RH incl. condensation / frost
tested in accordance with (no commissioning in bedewed state), (no commissioning in bedewed state), (no commissioning in bedewed state),
IEC 60068-2-38, max. horizontal installation horizontal installation horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the Yes; Incl. diesel and oil droplets in the Yes; Incl. diesel and oil droplets in the
available coolants and lubricants air air air
Use in stationary industrial
systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
of environmental conditions remain in place over the unused remain in place over the unused remain in place over the unused
acc. to EN 60721, EN 60654-4 interfaces during operation! interfaces during operation! interfaces during operation!
and ANSI/ISA-71.04
■ Technical specifications
2
Article number 6AG1055-1CB00-7BA2 6AG1055-1HB00-7BA2 6AG1055-1MB00-7BA2
Based on 6ED1055-1CB00-0BA2 6ED1055-1HB00-0BA2 6ED1055-1MB00-0BA2
SIPLUS LOGO! DM8 24 V8 SIPLUS LOGO! DM8 24R V8 SIPLUS LOGO! DM8 12/24R V8
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
acc. to EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
2
Article number 6AG1055-1FB00-7BA2 6AG1055-1NB10-7BA2
Based on 6ED1055-1FB00-0BA2 6ED1055-1NB10-0BA2
SIPLUS LOGO! DM8 230R V8 SIPLUS LOGO! DM16 24R V8
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling Yes; Type 1 protection Yes; Type 1 protection
acc. to EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance Yes; Conformal coating, Class A Yes; Conformal coating, Class A
of Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
2
Article number 6AG1055-1MA00-7BA2 6AG1055-1MD00-7BA2
Based on 6ED1055-1MA00-0BA2 6ED1055-1MD00-0BA2
SIPLUS LOGO! AM2 V8 SIPLUS LOGO! AM2 RTD
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling Yes; Type 1 protection Yes; Type 1 protection
acc. to EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Overview
Note on compatibility:
2 Communications module Can be used with:
LOGO! CMK2000 communications module LOGO! ...0BA8
LOGO! CSM 12/24 LOGO! ...0BA7/...0BA8
LOGO! CSM 230 LOGO! ...0BA7
LOGO! CMR2020 LOGO! ...0BA8
LOGO! CMR2040 LOGO! ...0BA8
2
Interfaces
Number of industrial Ethernet 1; Ethernet, 1 port, RJ45
interfaces
Number of other interfaces 1; EIB/KNX
Transmission rate, max. 100 Mbit/s over Ethernet,
9 600 bit/s over KNX
Design of plug-in connection KNX terminal 0.6 mm² - 1.0 mm²
Protocols
EIB/KNX Yes
Web server
• supported Yes
Communication functions
S7 basic communication
• supported No
LOGO! communication
• supported Yes
Interrupts/diagnostics/
status information
• Expansion module for LOGO! 8 basic versions Diagnostics indication LED
• For integrating LOGO! 8 in KNX installations • RUN/STOP LED Yes
• With 24 digital inputs, 20 digital outputs as well as 8 analog EMC
inputs and outputs for processing process signals via KNX. Emission of radio interference
acc. to EN 55 011
■ Ordering data Article No. • Limit class B,
for use in residential areas
Yes;
In accordance with EN 61000-6-3
LOGO! CMK2000 6BK1700-0BA20-0AA0 Standards, approvals, certificates
communications module CE mark Yes
For integrating LOGO! 8 CSA approval Yes
in the KNX building system bus,
max. 50 communication objects UL approval Yes
can be configured; cULus Yes
RJ45 port for Ethernet;
FM approval No
supply voltage 24 V DC/40 mA
RCM (formerly C-TICK) No
KC approval Yes
■ Technical specifications EAC (formerly Gost-R) Yes
according to VDE 0631 No
Article number 6BK1700-0BA20-0AA0
Marine approval No
LOGO! CMK2000
Ambient conditions
General information
Ambient temperature
Firmware version during operation
• FW update possible Yes • min. 0 °C
Installation type/mounting • max. 55 °C
Mounting on 35 mm DIN rail, Relative humidity
4 spacing units wide
• Operation, max. 95 %
Supply voltage
Connection method
Rated value (DC) 24 V
Design of electrical connection for 2 screw-type terminals: L+,
• 12 V DC No supply voltage M 0.5 mm² - 2.5 mm² Screw-type
• 24 V DC Yes terminal: FE 0.5 mm² ... 6.0 mm²
Rated value (AC) Dimensions
• 24 V AC No Width 71.5 mm; 4TE
Input current Height 90 mm
Current consumption, max. 0.04 A Depth 58.5 mm
Power loss Weights
Power loss, max. 1.1 W Weight, approx. 0.14 kg
Memory
Flash Yes
Time of day
Clock synchronization
• supported Yes
2
LOGO! CSM
compact switch modules
Unmanaged switch for connection
of one LOGO! and up to three
further nodes on Industrial Ethernet
with 10/100 Mbps; 4 x RJ45 ports;
LED diagnostics, LOGO! module
• LOGO! CSM12/24 6GK7177-1MA20-0AA0
external 12 V DC or
24 V DC power supply, for
LOGO! ... 0BA7/... 0BA8
• LOGO! CSM230 6GK7177-1FA10-0AA0
external 115 ... 240 V AC power
supply, for LOGO! ... 0BA7
Accessories
IE TP cord RJ45/RJ45
TP cable 4 x 2 with 2 RJ45 plugs
• 0.5 m 6XV1870-3QE50
•1m 6XV1870-3QH10
•2m 6XV1870-3QH20
The module is used to connect a LOGO! and up to three other •6m 6XV1870-3QH60
nodes to an Industrial Ethernet network with 10/100 Mbps in an • 10 m 6XV1870-3QN10
electrical linear, tree or star topology. IE FC outlet RJ45 6GK1901-1FC00-0AA0
The essential features of the LOGO! CSM are: For connection of
• Unmanaged 4-port switch, of which one port is on the front for Industrial Ethernet FC cables
and TP cords; graduated prices
easy diagnostics access for 10 and 50 units or more
• Two versions for the voltage ranges 12/24 V DC or
230 V AC/DC
• Problem-free connection using four RJ45 standard
connectors
• Space-saving, optimized for connection to LOGO!
• Low-cost solution for implementing small,
local Ethernet networks
• Stand-alone use for networking any Ethernet devices
■ Technical specifications
2
Article number 6GK7177-1FA10-0AA0 6GK7177-1MA20-0AA0
product type designation LOGO! CSM 230 LOGO! CSM 12/24
transfer rate
transfer rate 10 Mbit/s, 100 Mbit/s 10 Mbit/s, 100 Mbit/s
interfaces for communication
integrated
number of electrical connections
• for network components or 4 4
terminal equipment
number of 100 Mbit/s SC ports
• for multimode 0 0
number of 1000 Mbit/s LC ports
• for multimode 0 0
• for single mode (LD) 0 0
interfaces other
number of electrical connections
• for power supply 1 1
type of electrical connection
• for power supply 3-pole terminal block 3-pole terminal block
supply voltage, current
consumption, power loss
type of voltage 1 of the supply voltage DC DC
• supply voltage 1 rated value 230 V 24 V
• power loss [W] 1 rated value 1.5 W
• supply voltage 1 rated value 100 ... 240 V 10.2 ... 30.2 V
• consumed current 1 maximum 0.02 A 0.15 A
• type of electrical connection 1 3-pole terminal block 3-pole terminal block
for power supply
• product component 1 fusing Yes Yes
at power supply input
type of voltage 2 of the supply voltage
• supply voltage 2 rated value 100 ... 240 V
ambient conditions
ambient temperature
• during operation 0 ... 55 °C 0 ... 55 °C
• during storage -40 ... +70 °C -40 ... +70 °C
• during transport -40 ... +70 °C -40 ... +70 °C
relative humidity
• at 25 °C without condensation 90 % 90 %
during operation maximum
protection class IP IP20 IP20
design, dimensions and weights
design LOGO! module LOGO! module
width 72 mm 71.5 mm
height 90 mm 90 mm
depth 55 mm 58.2 mm
net weight 0.155 kg 0.15 kg
fastening method
• 35 mm top hat DIN rail mounting Yes Yes
• wall mounting Yes Yes
• S7-300 rail mounting No No
• S7-1500 rail mounting No No
■ Technical specifications
2
Article number 6GK7177-1FA10-0AA0 6GK7177-1MA20-0AA0
product type designation LOGO! CSM 230 LOGO! CSM 12/24
product functions management,
configuration, engineering
product function
• multiport mirroring No No
product function switch-managed No No
standards, specifications,
approvals
standard
• for FM FM3600 and 3611: CL. I, Div2, Group A,B,C,D T4, CL I,
Zone 2, Group IIC, T4, Ta=55°C
• for safety from CSA and UL UL60079-0, UL60079-15, CSA C22.2 UL 508, CSA C22.2 No. 142
standards, specifications,
approvals CE
certificate of suitability CE marking Yes Yes
standards, specifications,
approvals hazardous environments
standard for hazardous zone no ATEX: EN 60079-0 : 2009,EN 60079-15 :2010
(Directive 94/9/EC), IECEx: IEC 60079-0 :2011,
IEC 60079-15 :2010
• from CSA and UL Haz-Loc ANSI/ISA 12.12.01: CL. I, Div2,
Group A,B,C,D T4, CL I, Zone 2, Group IIC, T4, Ta=55°C
certificate of suitability
• CCC for hazardous zone Yes
according to GB standard
standards, specifications,
approvals other
certificate of suitability
• C-Tick Yes Yes
• KC approval No No
standards, specifications,
approvals marine classification
Marine classification association
• American Bureau of No No
Shipping Europe Ltd. (ABS)
• French marine classification society No No
(BV)
• Det Norske Veritas (DNV) No No
• Germanische Lloyd (GL) No No
• Lloyds Register of Shipping (LRS) No No
• Nippon Kaiji Kyokai (NK) No No
• Polski Rejestr Statkow (PRS) No No
2
Communications Module Radio
LOGO! CMR
Communications modules
for connection of LOGO! 8 to
GSM/GPRS or LTE network;
1x RJ45 port for Industrial Ethernet
connection;
2x digital input; 2x digital output;
read/write access to LOGO! tags;
possible to send/receive
text messages;
GPS position detection; time-of-day
synchronization/forwarding with real
time clock; configuration and
diagnostics per web interface;
Note country approvals:
www.siemens.com/mobilenetwork-
approvals
LOGO! CMR2020 6GK7142-7BX00-0AX0
For connecting LOGO! 8
to a GSM/GPRS network
LOGO! CMR in combination with the LOGO! logic module is a LOGO! CMR2040 6GK7142-7EX00-0AX0
cost-efficient communication system suitable for monitoring and For connecting LOGO! 8
controlling distributed plants and systems via text message or to an LTE network
email. Accessories
LOGO! CMR can send text messages or emails to predefined Mobile wireless antennas
mobile network numbers as well as receive text messages from ANT794-4MR 6NH9860-1AA00
predefined mobile network numbers. For indoor and outdoor use;
5 m connecting cable permanently
Sending a text message/email can be initiated by events in the connected to antenna;
LOGO! basic module as well as by the two digital alarm inputs SMA connector; incl. installation
of the LOGO! CMR. The values in the LOGO! logic module can bracket, screws, wall anchors
be directly influenced by receiving a text message. ANT896-4MA 6GK5896-4MA00-0AA3
The LOGO! CMR offers comfortable Web Based Management Rod antenna for direct mounting on
device; SMA male connector
commissioning and diagnostics via local and/or remote access.
ANT896-4ME 6GK5896-4ME00-0AA0
The two digital outputs can also be switched remotely by Cylinder-shaped antenna for
incoming text messages/emails. remote installation,
e.g. on a control cabinet;
LOGO! CMR determines the current position of the module N-Connect female connector
based on the GPS signal received by the GPS antenna. In addi- GPS antenna
tion, the LOGO! 8 logic module can be time-synchronized by
means of the time included in the GPS signal. Determination of ANT895-6ML 6GK5895-6ML00-0AA0
time by means of an NTP server or from the data of the mobile GPS/Glonass antenna for remote
installation indoor and outdoor,
network provider offers more options for synchronization of the magnet or screw mounting,
LOGO! BM with the current time of day. 30 cm cable with N-Connect female
connector
Product version:
Antenna adapter cable
• LOGO! CMR2020 for use in GSM/GPRS mobile wireless
networks N-Connect/SMA male/male flexible
connecting cable, pre-assembled,
• LOGO! CMR2040 for use in LTE mobile wireless networks connecting cable;
suitable for 0 ... 6 GHz, IP68
Warning! The country-specific mobile network approvals must • 0.3 m 6XV1875-5LE30
be observed: •1m 6XV1875-5LH10
DE: http://www.siemens.de/mobilfunkzulassungen •2m 6XV1875-5LH20
•5m 6XV1875-5LH50
EN: http://www.siemens.com/mobilenetwork-approvals
2
IWLAN RCoax/antenna Stainless steel enclosure 6NH3112-3BA00-1XX1
N-Connect male/male in IP68 degree of protection
flexible connecting cable
Stainless steel enclosure
Flexible connecting cable for in IP68 degree of protection;
connecting an RCoax cable or suitable for SIMATIC RTU3030C;
antenna to a SCALANCE W-700 temperature range -60 to +135 °C;
Access Point with N-Connect matte surface; cover with
connectors; pre-assembled with Pin Torx screws and padlock
two N-Connect male connectors; 7 cable openings and opening for
suitable from 0 ... 6 GHz, IP68 mobile wireless antenna prepared;
•1m 6XV1875-5AH10 please order the needed quantity of
•2m 6XV1875-5AH20 cable glands and sealing plugs
separately
•5m 6XV1875-5AH50
• 10 m 6XV1875-5AN10 Aluminum enclosure 6NH3112-3BA00-1XX3
in IP68 degree of protection
Cabinet feedthrough
Aluminum enclosure in IP68 degree
IWLAN RCOAX N-Connect/ 6GK5798-2PP00-2AA6 of protection; suitable for
N-Connect female/female SIMATIC RTU3030C; temperature
panel feedthrough; range -40 to +80 °C; cover with
Control cabinet feedthrough Pin Torx screws; 7 cable openings
for wall thickness max. 4.5 mm; and opening for mobile wireless
2.4 GHz and 5 GHz, antenna prepared; please order the
suitable from 0 ... 6 GHz, IP67 needed quantity of cable glands
and sealing plugs separately
Lightning protector LP798-2N
Cable gland PG16 F 6NH3112-3BA00-1XX4
Lightning protector with N/N 6GK5798-2LP00-2AA6
for IP68 enclosure
female/female connection for
ANT 790 antennas, Cable gland, M16, IP68,
IP67 (-40 to +85 °C), -40 to +100 °C; nickel-plated brass;
frequency range: 0 … 6 GHz suitable for enclosure
with article numbers
Patch cable
6NH3112-3BA00-1x X1 and
IE TP Cord RJ45/RJ45 6NH3112-3BA00-1x X3
pack quantity = 2 units
TP cable 4 x 2 with 2 RJ45 plugs
• 0.5 m 6XV1870-3QE50 Sealing plug M16 6NH3112-3BA00-1XX5
for IP68 enclosure
•1m 6XV1870-3QH10
•2m 6XV1870-3QH20 Sealing plug, M16, IP68,
•6m 6XV1870-3QH60 -40 to +100 °C; nickel-plated brass;
suitable for enclosure
• 10 m 6XV1870-3QN10 with article numbers
IE FC RJ45 outlet 6GK1901-1FC00-0AA0 6NH3112-3BA00-1x X1 and
6NH3112-3BA00-1x X3,
For connection of pack quantity = 2 units
Industrial Ethernet FC cables
and TP Cords; graduated prices
for 10 and 50 units or more
LOGO! CSM12/24 6GK7177-1MA20-0AA0
Compact Switch Module
for connecting a
LOGO! (...0BA7/...0BA8) and up to
3 additional nodes to Industrial
Ethernet; 12/24 V DC power supply
LOGO! CSM230 6GK7177-1FA10-0AA0
Compact Switch Module for
connecting a LOGO! (... 0BA7)
and up to 3 additional nodes
to Industrial Ethernet
115 ... 240 V AC/DC power supply
■ Technical specifications
2
Article number 6GK7142-7BX00-0AX0 6GK7142-7EX00-0AX0
product type designation LOGO! CMR2020 LOGO! CMR2040
transfer rate
transfer rate
• at the 1st interface 10 ... 100 Mbit/s 10 ... 100 Mbit/s
• for GPRS transmission
- with downlink maximum 80 kbit/s 85.6 kbit/s
- with uplink maximum 40 kbit/s 85.6 kbit/s
• for LTE transmission
- with downlink maximum 100 Mbit/s
- with uplink maximum 50 Mbit/s
interfaces
number of interfaces 1 1
acc. to Industrial Ethernet
number of electrical connections
• at the 1st interface 1 1
acc. to Industrial Ethernet
• for external antenna(s) 2 2
• for power supply 1 1
number of slots
• for SIM cards 1 1
• for memory cards 1 1
type of electrical connection
• at the 1st interface RJ45 port RJ45 port
acc. to Industrial Ethernet
type of electrical connection
• for external antenna(s) SMA socket (50 ohms) SMA socket (50 ohms)
• for power supply 3-pole terminal block 3-pole terminal block
type of antenna
• at connection 1 connectable GPS Antenna GPS Antenna
• at connection 2 connectable Mobile radio antenna (GPRS/GSM) Mobile radio antenna (GPRS/GSM, UMTS, LTE)
wire length of antenna wire maximum 15 m 15 m
slot version
• for SIM card Standard Standard
• of the memory card microSD microSD
storage capacity of the memory card 32 Gibyte 32 Gibyte
maximum
performance class of the memory Class 6 Class 6
card minimum necessary
type of file system type of file system FAT32 FAT32
signal inputs/outputs
number of electrical connections 2 2
for digital input signals
type of electrical connection 3 pole terminal block 3 pole terminal block
for digital input signals
digital input version not galvanically isolated, not debounced not galvanically isolated, not debounced
input voltage at digital input
• with signal <0> at DC 0 ... 5 V 0 ... 5 V
• for signal <1> at DC 8.5 ... 24 V 8.5 ... 24 V
input current at digital input 5.5 mA 5.5 mA
for signal <1> maximum
number of electrical connections 2 2
for digital output signals
■ Technical specifications
2
Article number 6GK7142-7BX00-0AX0 6GK7142-7EX00-0AX0
product type designation LOGO! CMR2020 LOGO! CMR2040
type of electrical connection 3 pole terminal block 3 pole terminal block
for digital output signals
digital output version transistor, not potential seperated transistor, not potential seperated
output voltage at digital output
• for signal <1> 12 ... 24 V; Value of the actual supply voltage 12 ... 24 V; Value of the actual supply voltage
• for signal <0> 0 ... 5 V 0 ... 5 V
output current at digital output 0.3 A 0.3 A
for signal <1> maximum
wireless technology
type of mobile wireless service
• is supported SMS Yes Yes
• is supported GPRS Yes Yes
• note GPRS (Multislot Class 10, Mobile Station Class B) LTE
type of wireless network is supported
• GSM Yes Yes
• UMTS No Yes
• LTE No Yes
operating frequency operating frequency for GSM transmission 850 operating frequency for GSM transmission 900
for GSM transmission MHz, operating frequency for GSM transmission 900 MHz, operating frequency for GSM transmission 1800 MHz
MHz, operating frequency for GSM transmission 1800
MHz, operating frequency for GSM transmission 1900 MHz
operating frequency operating frequency with UMTS transmission 850
with UMTS transmission MHz, operating frequency with UMTS transmission 900
MHz, operating frequency with UMTS transmission 2100
MHz
operating frequency operating frequency for LTE transmission 800
for LTE transmission MHz, operating frequency for LTE transmission 1800
MHz, operating frequency for LTE transmission 2600 MHz
supply voltage, current
consumption, power loss
type of voltage of the supply voltage DC DC
supply voltage external 12 ... 24 V 12 ... 24 V
supply voltage external at DC 12 ... 24 V 12 ... 24 V
supply voltage for GPS antenna 3.8 V; at 5 mA: 3,575 V / at 10 mA: 3,35 V / 3.8 V; at 5 mA: 3,575 V / at 10 mA: 3,35 V /
maximum at 15 mA: 3,125 V at 15 mA: 3,125 V
relative positive tolerance 20 % 20 %
at DC at 24 V
relative negative tolerance 10 % 10 %
at DC at 12 V
consumed current
• from external supply voltage 0.25 A 0.25 A
at DC at 12 V maximum
• from external supply voltage 0.125 A 0.125 A
at DC at 24 V maximum
output current for GPS antenna 15 mA 15 mA
maximum
power loss [W] 3W 3W
ambient conditions
ambient temperature
• during operation -20 ... +70 °C -20 ... +70 °C
• during storage -40 ... +85 °C -40 ... +85 °C
• during transport -40 ... +85 °C -40 ... +85 °C
relative humidity
• at 25 °C without condensation 95 % 95 %
during operation maximum
protection class IP IP20 IP20
■ Technical specifications
2
Article number 6GK7142-7BX00-0AX0 6GK7142-7EX00-0AX0
product type designation LOGO! CMR2020 LOGO! CMR2040
design, dimensions and weights
module format Compact module, for rail mounting Compact module, for rail mounting
width 71.5 mm 71.5 mm
height 90 mm 90 mm
depth 58.2 mm 58.2 mm
net weight 0.16 kg 0.16 kg
fastening method
• 35 mm top hat DIN rail mounting Yes Yes
• wall mounting Yes Yes
product features,
product functions,
product components general
product function
• DynDNS client Yes Yes
• no-ip.com client Yes Yes
performance data
number of possible connections to 1 1
the LOGO! logic module
number of users/telephone 20 20
numbers/email addresses definable
maximum
number of user groups definable 10 10
maximum
number of signals for monitoring or 32 32
device control definable maximum
number of events for monitoring 32 32
definable maximum
number of actions definable maximum 32 32
number of assignments definable 32 32
maximum
number of alias SMS commands 20 20
definable maximum
number of constants definable 10 10
maximum
performance data IT functions
number of possible connections
• as server by means of HTTP 2 2
maximum
• as server by means of HTTPS 2; http and https can be combined (max. number of 2; http and https can be combined (max. number of
maximum 2 connections cannot be exceeded). Max. one connection 2 connections cannot be exceeded). Max. one connection
via https is possible on the mobile wireless interface. via https is possible on the mobile wireless interface.
• as email client maximum 1 1
number of free texts for emails and 20 20
SMS maximum
number of characters per free text 160 160
for emails or SMS maximum
performance data teleservice
product function
• remote firmware update Yes Yes
• remote configuration Yes Yes
product functions management,
configuration, engineering
configuration software
• required Web interface Web interface
product functions diagnostics
product function web-based Yes Yes
diagnostics
■ Technical specifications
2
Article number 6GK7142-7BX00-0AX0 6GK7142-7EX00-0AX0
product type designation LOGO! CMR2020 LOGO! CMR2040
product functions security
operating mode Yes; Open VPN Server in PSK mode Yes; Open VPN Server in PSK mode
Virtual Private Network (VPN)
product function with VPN connection OpenVPN PSK OpenVPN PSK
type of encryption algorithms AES-128 CBC AES-128 CBC
with VPN connection
type of authentication Yes Yes
with Virtual Private Network PSK
type of hashing algorithms SHA-256 SHA-256
with VPN connection
number of possible connections 1 1
with VPN connection
product function
• password protection Yes Yes
for Web applications
• password protection for VPN Yes Yes
• encrypted data transmission Yes Yes
• switch-off of non-required services Yes Yes
• log file for unauthorized access Yes Yes
product functions time
product function pass on time Yes Yes
synchronization
accuracy of the hardware real time 7.5 s 7.5 s
clock per day maximum
time synchronization
• from NTP-server Yes Yes
• from GPS-signal Yes Yes
• from mobile network provider Yes Yes
• PC Yes Yes
• manual setting Yes Yes
product functions
position detection
product function
• position detection with GPS Yes Yes
• pass on position data Yes Yes
standards, specifications,
approvals hazardous environments
certificate of suitability CCC Yes Yes
for hazardous zone according to
GB standard
■ Overview
Product highlights of the product line
• Low width 2
with minimum of 18 mm to maximum of 72 mm, thus requiring
very little space in the control cabinet or distribution board
• High energy efficiency
with efficiency levels of up to 90% over the entire performance
range and ERP-compliant no-load losses of < 0.3 W
• Global use
due to operating temperature range from -25 °C to +70 °C and
international certificates
• Supply
of NEC Class 2 electric circuits with limited output current
(100 VA)
• Load monitoring via current monitor
using real-time measurement of the output current
without disconnecting the cable, i.e. without interrupting the
DC supply
• Flexible mounting
The flat power supply unit for distribution boards with top hat DIN rail or wall mounting in different installation
positions
Small. Clever. LOGO!Power: Thanks to its stepped profile de-
sign, the LOGO! 8 product line is ideally suited for installation in • Flexible operation
small distribution boards. The 12 V and 24 V versions are ideal in all standard 1-phase supply networks thanks to wide-range
for supplying LOGO! controllers with the corresponding voltage input of 100 … 240 V AC without switchover and operation on
input. The high level of efficiency across the entire load range as DC networks with 110 … 300 V DC
well as the low no-load losses result in lower overall energy • Reliability
consumption. Greater convenience when commissioning and due to problem-free connection of loads with high inrush
servicing thanks to the integrated current monitor. The extended currents thanks to power reserve during startup as well as
ambient temperature range from -25 °C to +70 °C enables a host constant current in the event of overload
of additional applications.
To further increase 24 V availability, the 24 V LOGO!Power power
supplies can be combined with the buffer module BUF1200,
DC UPS, redundancy and selectivity modules.
This powerhouse can be used in any industry: e.g. in building
technology applications for light and heating controllers or for
access control systems. LOGO!Power is also well-suited for use
in industrial automation, such as in packaging machine,
machine tool, conveyor belt or sorting system applications.
■ Overview
Thanks to its stepped profile design, the LOGO!Power product
2 line is ideally suited for installation in small distribution boards.
The stabilized power supplies with wide-range input are avail-
able with an output voltage of 5 V in two performance classes.
Product highlights
• Single-phase, 5 V DC/ 3 A and 6.3 A
• Wide-range input, input voltage 100 … 240 V AC
(85 … 264 V), 110 … 300 V DC
• Narrow unit with 36 mm or 54 mm width and overall depth of
53 mm in LOGO! design
• Up to 80% efficiency
• Integrated current monitor: Actual output current
measurement directly at the power supply unit
• cULus, cURus, NEC class 2, ABS, DNV GL certifications
■ Technical specifications
Article number 6EP3310-6SB00-0AY0 6EP3311-6SB00-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 5 V/3 A 5 V/6.3 A
Input
Input 1-phase AC or DC 1-phase AC or DC
Rated voltage value Vin rated 100 ... 240 V 100 ... 240 V
Voltage range AC 85 ... 264 V 85 ... 264 V
input voltage
• at DC 110 ... 300 V 110 ... 300 V
Wide-range input Yes Yes
Overvoltage resistance 300 V AC for 1 s 300 V AC for 1 s
Mains buffering at Vin = 187 V at Vin = 187 V
Mains buffering at Iout rated, min. 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V
Rated line frequency 1 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz
Rated line range 47 ... 63 Hz 47 ... 63 Hz
input current
• at rated input voltage 120 V 0.36 A 0.71 A
• at rated input voltage 230 V 0.22 A 0.37 A
Switch-on current limiting (+25 °C), 26 A 50 A
max.
I²t, max. 0.8 A²·s 3 A²·s
Built-in incoming fuse internal internal
Protection in the mains power input Recommended miniature circuit breaker: Recommended miniature circuit breaker:
(IEC 898) from 6 A characteristic B or from 2 A characteristic C from 10 A characteristic B or from 6 A characteristic C
■ Technical specifications
2
Article number 6EP3310-6SB00-0AY0 6EP3311-6SB00-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 5 V/3 A 5 V/6.3 A
Output
Output Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage Vout DC 5V 5V
■ Technical specifications
2
Article number 6EP3310-6SB00-0AY0 6EP3311-6SB00-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 5 V/3 A 5 V/6.3 A
Safety
Primary/secondary isolation Yes Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178 and EN 50178
Protection class Class II (without protective conductor) Class II (without protective conductor)
Degree of protection (EN 60529) IP20 IP20
Approvals
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), cULus-listed (UL 508, CSA C22.2 No. 107.1), File E197259;
File E197259; cURus-Recognized (UL 60950, CSA C22.2 cURus-recognized (UL 60950, CSA C22.2 No. 60950),
No. 60950), File E151273, NEC class 2 (acc. to UL 1310) File E151273
Explosion protection ATEX (EX) II 3G Ex nA IIC T3; cULus Class I Div. 2 ATEX (EX) II 3G Ex nA IIC T3; cULus Class I Div. 2
(ANSI/ISA-12.12.01, CSA C22.2 No. 213) Group ABCD, T4, (ANSI/ISA-12.12.01, CSA C22.2 No. 213) Group ABCD, T4,
File E488866 File E488866
certificate of suitability NEC Class 2 Yes No
FM approval Class I, Div. 2, Group ABCD, T4 Class I, Div. 2, Group ABCD, T4
CB approval Yes Yes
certificate of suitability EAC approval Yes Yes
Marine approval ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation not applicable not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2
environmental conditions
ambient temperature
• during operation -25 ... +70 °C -25 ... +70 °C
- Note with natural convection with natural convection
• during transport -40 ... +85 °C -40 ... +85 °C
• during storage -40 ... +85 °C -40 ... +85 °C
Humidity class according to Climate class 3K3, 5 … 95% no condensation Climate class 3K3, 5 … 95% no condensation
EN 60721
Mechanics
Connection technology screw-type terminals screw-type terminals
Connections
• Supply input L, N: 1 screw terminal each for 0.5 ... 2.5 mm² L, N: 1 screw terminal each for 0.5 ... 2.5 mm²
single-core/finely stranded single-core/finely stranded
• Output +, -: 1 screw terminal each for 0.5 ... 2.5 mm² +, -: 1 screw terminal each for 0.5 ... 2.5 mm²
• Auxiliary - -
width of the enclosure 36 mm 54 mm
height of the enclosure 90 mm 90 mm
depth of the enclosure 53 mm 53 mm
required spacing
• top 20 mm 20 mm
• bottom 20 mm 20 mm
• left 0 mm 0 mm
• right 0 mm 0 mm
Weight, approx. 0.12 kg 0.2 kg
product feature of the enclosure Yes Yes
housing can be lined up
Installation Snaps onto DIN rail EN 60715 35x7.5/15, Snaps onto DIN rail EN 60715 35x7.5/15,
direct mounting in different mounting positions direct mounting in different mounting positions
MTBF at 40 °C 2 931 709 h 2 654 280 h
other information Specifications at rated input voltage and ambient Specifications at rated input voltage and ambient
temperature +25 °C (unless otherwise specified) temperature +25 °C (unless otherwise specified)
■ Overview
Thanks to its stepped profile design, the LOGO!Power product
line is ideally suited for installation in small distribution boards.
The stabilized power supplies with wide-range input are avail-
2
able with an output voltage of 12 V in three performance classes.
The 12 V versions are ideal for supplying LOGO! PLCs with the
corresponding voltage input.
Product highlights
• Single-phase, 12 V DC/ 0.9 A, 1.9 A and 4.5 A
• Wide-range input, input voltage 100 … 240 V AC
(85 … 264 V), 110 … 300 V DC
• Narrow unit with width of 18 mm, 36 mm or 54 mm and overall
depth of 53 mm in LOGO! design
• Up to 87.1% efficiency
• Integrated current monitor: Actual output current
measurement directly at the power supply unit
(for devices at least 36 mm wide)
• cULus, cURus, NEC class 2, ABS, DNV GL certifications
■ Technical specifications
Article number 6EP3320-6SB00-0AY0 6EP3321-6SB00-0AY0 6EP3322-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power
Power supply, type 12 V/0.9 A 12 V/1.9 A 12 V/4.5 A
Input
Input 1-phase AC or DC 1-phase AC or DC 1-phase AC or DC
Rated voltage value Vin rated 100 ... 240 V 100 ... 240 V 100 ... 240 V
Voltage range AC 85 ... 264 V 85 ... 264 V 85 ... 264 V
input voltage
• at DC 110 ... 300 V 110 ... 300 V 110 ... 300 V
Wide-range input Yes Yes Yes
Overvoltage resistance 300 V AC for 1 s 300 V AC for 1 s 300 V AC for 1 s
Mains buffering at Vin = 187 V at Vin = 187 V at Vin = 187 V
Mains buffering at Iout rated, min. 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V
Rated line frequency 1 50 Hz 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz 60 Hz
Rated line range 47 ... 63 Hz 47 ... 63 Hz 47 ... 63 Hz
input current
• at rated input voltage 120 V 0.3 A 0.53 A 1.13 A
• at rated input voltage 230 V 0.2 A 0.3 A 0.61 A
Switch-on current limiting (+25 °C), 20 A 25 A 50 A
max.
I²t, max. 0.8 A²·s 0.8 A²·s 3 A²·s
Built-in incoming fuse internal internal internal
Protection in the mains power input Recommended miniature circuit Recommended miniature circuit Recommended miniature circuit
(IEC 898) breaker: from 6 A characteristic B or breaker: from 6 A characteristic B or breaker: from 10 A characteristic B or
from 2 A characteristic C from 2 A characteristic C from 6 A characteristic C
■ Technical specifications
2
Article number 6EP3320-6SB00-0AY0 6EP3321-6SB00-0AY0 6EP3322-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power
Power supply, type 12 V/0.9 A 12 V/1.9 A 12 V/4.5 A
Output
Output Controlled, isolated DC voltage Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage Vout DC 12 V 12 V 12 V
■ Technical specifications
2
Article number 6EP3320-6SB00-0AY0 6EP3321-6SB00-0AY0 6EP3322-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power
Power supply, type 12 V/0.9 A 12 V/1.9 A 12 V/4.5 A
Safety
Primary/secondary isolation Yes Yes Yes
galvanic isolation Safety extra-low output voltage Uout Safety extra-low output voltage Uout Safety extra-low output voltage Uout
acc. to EN 60950-1 and EN 50178 acc. to EN 60950-1 and EN 50178 acc. to EN 60950-1 and EN 50178
Protection class Class II (without protective conductor) Class II (without protective conductor) Class II (without protective conductor)
Degree of protection (EN 60529) IP20 IP20 IP20
Approvals
CE mark Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, cULus-Listed (UL 508, cULus-Listed (UL 508,
CSA C22.2 No. 107.1), File E197259; CSA C22.2 No. 107.1), File E197259; CSA C22.2 No. 107.1), File E197259;
cURus-Recognized (UL 60950, cURus-Recognized (UL 60950, cURus-Recognized (UL 60950,
CSA C22.2 No. 60950), File E151273, CSA C22.2 No. 60950), File E151273, CSA C22.2 No. 60950), File E151273,
NEC class 2 (acc. to UL 1310) NEC class 2 (acc. to UL 1310) NEC class 2 (acc. to UL 1310)
Explosion protection ATEX (EX) II 3G Ex nA IIC T3; ATEX (EX) II 3G Ex nA IIC T3; ATEX (EX) II 3G Ex nA IIC T3;
cULus Class I Div. 2 cULus Class I Div. 2 cULus Class I Div. 2
(ANSI/ISA-12.12.01, (ANSI/ISA-12.12.01, (ANSI/ISA-12.12.01,
CSA C22.2 No. 213) Group ABCD, T4, CSA C22.2 No. 213) Group ABCD, T4, CSA C22.2 No. 213) Group ABCD, T4,
File E488866 File E488866 File E488866
certificate of suitability NEC Class 2 Yes Yes No
FM approval Class I, Div. 2, Group ABCD, T4 Class I, Div. 2, Group ABCD, T4 Class I, Div. 2, Group ABCD, T4
CB approval Yes Yes Yes
certificate of suitability EAC approval Yes Yes Yes
Marine approval ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation not applicable not applicable not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
environmental conditions
ambient temperature
• during operation -25 ... +70 °C -25 ... +70 °C -25 ... +70 °C
- Note with natural convection with natural convection with natural convection
• during transport -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
• during storage -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
Humidity class according to Climate class 3K3, 5 … 95% Climate class 3K3, 5 … 95% Climate class 3K3, 5 … 95%
EN 60721 no condensation no condensation no condensation
Mechanics
Connection technology screw-type terminals screw-type terminals screw-type terminals
Connections
• Supply input L, N: 1 screw terminal each L, N: 1 screw terminal each L, N: 1 screw terminal each
for 0.5 ... 2.5 mm2 single-core/ for 0.5 ... 2.5 mm2 single-core/ for 0.5 ... 2.5 mm2 single-core/
finely stranded finely stranded finely stranded
• Output +, -: 1 screw terminal each +, -: 1 screw terminal each +, -: 1 screw terminal each
for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm²
• Auxiliary - - -
width of the enclosure 18 mm 36 mm 54 mm
height of the enclosure 90 mm 90 mm 90 mm
depth of the enclosure 53 mm 53 mm 53 mm
required spacing
• top 20 mm 20 mm 20 mm
• bottom 20 mm 20 mm 20 mm
• left 0 mm 0 mm 0 mm
• right 0 mm 0 mm 0 mm
Weight, approx. 0.07 kg 0.12 kg 0.2 kg
product feature of the enclosure Yes Yes Yes
housing can be lined up
Installation Snaps onto DIN rail EN 60715 Snaps onto DIN rail EN 60715 Snaps onto DIN rail EN 60715
35x7.5/15, direct mounting in different 35x7.5/15, direct mounting in different 35x7.5/15, direct mounting in different
mounting positions mounting positions mounting positions
MTBF at 40 °C 3 793 080 h 2 938 542 h 2 566 680 h
other information Specifications at rated input voltage Specifications at rated input voltage Specifications at rated input voltage
and ambient temperature +25 °C and ambient temperature +25 °C and ambient temperature +25 °C
(unless otherwise specified) (unless otherwise specified) (unless otherwise specified)
■ Overview
Thanks to its stepped profile design, the LOGO!Power product
2 line is ideally suited for installation in small distribution boards.
The stabilized power supplies with a wide-range input are avail-
able with an output voltage of 15 V in two performance classes.
Product highlights
• Single-phase, 15 V DC/ 1.9 A and 4.0 A
• Wide-range input, input voltage 100 … 240 V AC
(85 … 264 V), 110 … 300 V DC
• Narrow unit with 36 mm or 54 mm width and overall depth of
53 mm in LOGO! design
• Up to 88.4% efficiency
• Integrated current monitor: Actual output current
measurement directly at the power supply unit
• cULus, cURus, NEC class 2, ABS, BV, DNV GL,
LRS certifications
■ Technical specifications
Article number 6EP3321-6SB10-0AY0 6EP3322-6SB10-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 15 V/1.9 A 15 V/4 A
Input
Input 1-phase AC or DC 1-phase AC or DC
Rated voltage value Vin rated 100 ... 240 V 100 ... 240 V
Voltage range AC 85 ... 264 V 85 ... 264 V
input voltage
• at DC 110 ... 300 V 110 ... 300 V
Wide-range input Yes Yes
Overvoltage resistance 300 V AC for 1 s 300 V AC for 1 s
Mains buffering at Vin = 187 V at Vin = 187 V
Mains buffering at Iout rated, min. 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V
Rated line frequency 1 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz
Rated line range 47 ... 63 Hz 47 ... 63 Hz
input current
• at rated input voltage 120 V 0.63 A 1.24 A
• at rated input voltage 230 V 0.33 A 0.68 A
Switch-on current limiting (+25 °C), 25 A 55 A
max.
I²t, max. 0.8 A²·s 3 A²·s
Built-in incoming fuse internal internal
Protection in the mains power input Recommended miniature circuit breaker: Recommended miniature circuit breaker:
(IEC 898) from 6 A characteristic B or from 2 A characteristic C from 10 A characteristic B or from 6 A characteristic C
■ Technical specifications
2
Article number 6EP3321-6SB10-0AY0 6EP3322-6SB10-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 15 V/1.9 A 15 V/4 A
Output
Output Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage Vout DC 15 V 15 V
■ Technical specifications
2
Article number 6EP3321-6SB10-0AY0 6EP3322-6SB10-0AY0
Product LOGO!Power LOGO!Power
Power supply, type 15 V/1.9 A 15 V/4 A
Safety
Primary/secondary isolation Yes Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178 and EN 50178
Protection class Class II (without protective conductor) Class II (without protective conductor)
Degree of protection (EN 60529) IP20 IP20
Approvals
CE mark Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), cULus-Listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-Recognized (UL 60950, CSA C22.2 File E197259; cURus-Recognized (UL 60950, CSA C22.2
No. 60950), File E151273, NEC class 2 (acc. to UL 1310) No. 60950), File E151273, NEC class 2 (acc. to UL 1310)
Explosion protection ATEX (EX) II 3G Ex nA IIC T3; cULus Class I Div. 2 ATEX (EX) II 3G Ex nA IIC T3; cULus Class I Div. 2
(ANSI/ISA-12.12.01, CSA C22.2 No. 213) Group ABCD, T4, (ANSI/ISA-12.12.01, CSA C22.2 No. 213) Group ABCD, T4,
File E488866 File E488866
certificate of suitability NEC Class 2 Yes Yes
FM approval Class I, Div. 2, Group ABCD, T4 Class I, Div. 2, Group ABCD, T4
CB approval Yes Yes
certificate of suitability EAC approval Yes Yes
Marine approval ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS
EMC
Emitted interference EN 55022 Class B EN 55022 Class B
Supply harmonics limitation not applicable not applicable
Noise immunity EN 61000-6-2 EN 61000-6-2
environmental conditions
ambient temperature
• during operation -25 ... +70 °C -25 ... +70 °C
- Note with natural convection with natural convection
• during transport -40 ... +85 °C -40 ... +85 °C
• during storage -40 ... +85 °C -40 ... +85 °C
Humidity class according to Climate class 3K3, 5 … 95% no condensation Climate class 3K3, 5 … 95% no condensation
EN 60721
Mechanics
Connection technology screw-type terminals screw-type terminals
Connections
• Supply input L, N: 1 screw terminal each for 0.5 ... 2.5 mm² L, N: 1 screw terminal each for 0.5 ... 2.5 mm²
single-core/finely stranded single-core/finely stranded
• Output +, -: 1 screw terminal each for 0.5 ... 2.5 mm² +, -: 1 screw terminal each for 0.5 ... 2.5 mm²
• Auxiliary - -
width of the enclosure 36 mm 54 mm
height of the enclosure 90 mm 90 mm
depth of the enclosure 53 mm 53 mm
required spacing
• top 20 mm 20 mm
• bottom 20 mm 20 mm
• left 0 mm 0 mm
• right 0 mm 0 mm
Weight, approx. 0.12 kg 0.2 kg
product feature of the enclosure Yes Yes
housing can be lined up
Installation Snaps onto DIN rail EN 60715 35x7.5/15, Snaps onto DIN rail EN 60715 35x7.5/15,
direct mounting in different mounting positions direct mounting in different mounting positions
MTBF at 40 °C 2 938 542 h 2 566 680 h
other information Specifications at rated input voltage and Specifications at rated input voltage and
ambient temperature +25 °C (unless otherwise specified) ambient temperature +25 °C (unless otherwise specified)
2
LOGO!Power 1-phase,
24 V DC/0.6 A
Stabilized power supply 6EP3330-6SB00-0AY0
Input: 100 … 240 V AC
(110 ... 300 V DC)
Output: 24 V DC/0.6 A
LOGO!Power 1-phase,
24 V DC/1.3 A
Stabilized power supply 6EP3331-6SB00-0AY0
Input: 100 … 240 V AC
(110 ... 300 V DC)
Output: 24 V DC/1.3 A
LOGO!Power 1-phase,
24 V DC/2.5 A
Stabilized power supply 6EP3332-6SB00-0AY0
Thanks to its stepped profile design, the LOGO!Power product Input: 100 … 240 V AC
line is ideally suited for installation in small distribution boards. (110 ... 300 V DC)
Output: 24 V DC/2.5 A
The stabilized power supplies with wide-range input are avail-
able with an output voltage of 24 V in four performance classes. LOGO!Power 1-phase,
The 24 V versions are ideal for supplying LOGO! PLCs with the 24 V DC/4 A
corresponding voltage input. Stabilized power supply 6EP3333-6SB00-0AY0
Input: 100 … 240 V AC
To further increase the 24 V availability, the LOGO!Power power (110 ... 300 V DC)
supplies can be combined with DC UPS, redundancy and Output: 24 V DC/4 A
selectivity modules. Add-on modules
Product highlights SITOP redundancy modules For more information, visit:
https://www.siemens.com/
• Single-phase, 24 V DC/ 0.6 A, 1.3 A, 2.5 A and 4.0 A sitop-redundancy/mall
• Input voltage 100 … 240 V AC (85 … 264 V), 110 … 300 V DC SITOP selectivity modules For more information, visit:
• Narrow unit with width of 18 mm, 36 mm, 54 mm or 72 mm and https://www.siemens.com/
overall depth of 53 mm in LOGO! design sitop-selectivity/mall
• Up to 90% efficiency SITOP buffer module BUF1200 For more information, visit:
https://www.siemens.com/
• Integrated current monitor: Actual output current sitop-buffering/mall
measurement directly at the power supply unit DC UPS modules
(for devices at least 36 mm wide)
SITOP DC UPS For more information, visit:
• cULus, cURus, NEC class 2, ABS, BV, DNV GL, https://www.siemens.com/
LRS certifications sitop-ups/mall
■ Technical specifications
2
Article number 6EP3330-6SB00-0AY0 6EP3331-6SB00-0AY0 6EP3332-6SB00-0AY0 6EP3333-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power LOGO!Power
Power supply, type 24 V/0.6 A 24 V/1.3 A 24 V/2.5 A 24 V/4 A
Input
Input 1-phase AC or DC 1-phase AC or DC 1-phase AC or DC 1-phase AC or DC
Rated voltage value Vin rated 100 ... 240 V 100 ... 240 V 100 ... 240 V 100 ... 240 V
Voltage range AC 85 ... 264 V 85 ... 264 V 85 ... 264 V 85 ... 264 V
input voltage
• at DC 110 ... 300 V 110 ... 300 V 110 ... 300 V 110 ... 300 V
Wide-range input Yes Yes Yes Yes
Overvoltage resistance 300 V AC for 1 s 300 V AC for 1 s 300 V AC for 1 s 300 V AC for 1 s
Mains buffering at Vin = 187 V at Vin = 187 V at Vin = 187 V at Vin = 187 V
Mains buffering at Iout rated, min. 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V 40 ms; at Vin = 187 V
Rated line frequency 1 50 Hz 50 Hz 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz 60 Hz 60 Hz
Rated line range 47 ... 63 Hz 47 ... 63 Hz 47 ... 63 Hz 47 ... 63 Hz
input current
• at rated input voltage 120 V 0.3 A 0.7 A 1.22 A 1.95 A
• at rated input voltage 230 V 0.2 A 0.35 A 0.66 A 0.97 A
Switch-on current limiting (+25 °C), 20 A 25 A 52 A 31 A
max.
I²t, max. 0.8 A²·s 0.8 A²·s 3 A²·s 2.5 A²·s
Built-in incoming fuse internal internal internal internal
Protection in the mains power input Recommended miniature Recommended miniature Recommended miniature Recommended miniature
(IEC 898) circuit breaker: from 6 A circuit breaker: from 6 A circuit breaker: from 10 A circuit breaker: from 10 A
characteristic B or from 2 A characteristic B or from 2 A characteristic B or from 6 A characteristic B or from 6 A
characteristic C characteristic C characteristic C characteristic C
Output
Output Controlled, isolated Controlled, isolated Controlled, isolated Controlled, isolated
DC voltage DC voltage DC voltage DC voltage
Rated voltage Vout DC 24 V 24 V 24 V 24 V
■ Technical specifications
2
Article number 6EP3330-6SB00-0AY0 6EP3331-6SB00-0AY0 6EP3332-6SB00-0AY0 6EP3333-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power LOGO!Power
Power supply, type 24 V/0.6 A 24 V/1.3 A 24 V/2.5 A 24 V/4 A
Efficiency
Efficiency at Vout rated, Iout rated, 81 % 86 % 90 % 89 %
approx.
Power loss at Vout rated, Iout rated, 3W 5W 7W 12 W
approx.
power loss [W] during no-load 0.3 W 0.3 W 0.3 W 0.3 W
operation maximum
Closed-loop control
Dynamic mains compensation 0.2 % 0.2 % 0.2 % 0.2 %
(Vin rated ±15 %), max.
Dynamic load smoothing 2% 1% 2% 2%
(Iout: 10/90/10 %), Uout ± typ.
Load step setting time 10 to 90%, typ. 1 ms 1 ms 1 ms 1 ms
Load step setting time 90 to 10%, typ. 1 ms 1 ms 1 ms 1 ms
Protection and monitoring
Output overvoltage protection Yes, according to Yes, according to Yes, according to Yes, according to
EN 60950-1 EN 60950-1 EN 60950-1 EN 60950-1
Current limitation, typ. 0.8 A 1.7 A 3.2 A 5A
property of the output short-circuit Yes Yes Yes Yes
proof
Short-circuit protection Constant current Constant current Constant current Constant current
characteristic characteristic characteristic characteristic
enduring short circuit current
RMS value
• maximum 0.8 A 1.7 A 3.2 A 5A
overcurrent overload capability overload capability 150% overload capability 150% overload capability 150% overload capability 150%
in normal operation Iout rated typ. 200 ms Iout rated typ. 200 ms Iout rated typ. 200 ms Iout rated typ. 200 ms
Overload/short-circuit indicator - - - -
measuring point for output current 50 mV =^ 1.3 A 50 mV =^ 2.5 A 50 mV =^ 4 A
overcurrent overload capability when 150% Iout rated typ. 200 ms 150% Iout rated typ. 200 ms 150% Iout rated typ. 200 ms 150% Iout rated typ. 200 ms
switching on
Safety
Primary/secondary isolation Yes Yes Yes Yes
galvanic isolation Safety extra-low output Safety extra-low output Safety extra-low output Safety extra-low output
voltage Uout acc. to voltage Uout acc. to voltage Uout acc. to voltage Uout acc. to
EN 60950-1 and EN 50178 EN 60950-1 and EN 50178 EN 60950-1 and EN 50178 EN 60950-1 and EN 50178
Protection class Class II (without protective Class II (without protective Class II (without protective Class II (without protective
conductor) conductor) conductor) conductor)
Degree of protection (EN 60529) IP20 IP20 IP20 IP20
Approvals
CE mark Yes Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, cULus-Listed (UL 508, cULus-Listed (UL 508, cULus-listed (UL 508,
CSA C22.2 No. 107.1), CSA C22.2 No. 107.1), CSA C22.2 No. 107.1), CSA C22.2 No. 107.1),
File E197259; File E197259; File E197259; File E197259;
cURus-Recognized cURus-Recognized cURus-Recognized cURus-recognized
(UL 60950, CSA C22.2 (UL 60950, CSA C22.2 (UL 60950, CSA C22.2 (UL 60950, CSA C22.2
No. 60950), File E151273, No. 60950), File E151273, No. 60950), File E151273, No. 60950), File E151273
NEC class 2 NEC class 2 NEC class 2
(acc. to UL 1310) (acc. to UL 1310) (acc. to UL 1310)
Explosion protection ATEX (EX) II 3G Ex nA IIC T3; ATEX (EX) II 3G Ex nA IIC T3; ATEX (EX) II 3G Ex nA IIC T3; ATEX (EX) II 3G Ex nA IIC T3;
cULus Class I Div. 2 cULus Class I Div. 2 cULus Class I Div. 2 cULus Class I Div. 2
(ANSI/ISA-12.12.01, (ANSI/ISA-12.12.01, (ANSI/ISA-12.12.01, (ANSI/ISA-12.12.01,
CSA C22.2 No. 213) CSA C22.2 No. 213) CSA C22.2 No. 213) CSA C22.2 No. 213)
Group ABCD, T4, Group ABCD, T4, Group ABCD, T4, Group ABCD, T4,
File E488866 File E488866 File E488866 File E488866
certificate of suitability NEC Class 2 Yes Yes Yes No
FM approval Class I, Div. 2, Class I, Div. 2, Class I, Div. 2, Class I, Div. 2,
Group ABCD, T4 Group ABCD, T4 Group ABCD, T4 Group ABCD, T4
CB approval Yes Yes Yes Yes
certificate of suitability EAC approval Yes Yes Yes Yes
Marine approval ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS ABS, BV, DNV GL, LRS
EMC
Emitted interference EN 55022 Class B EN 55022 Class B EN 55022 Class B EN 55022 Class B
Supply harmonics limitation not applicable not applicable not applicable EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
■ Technical specifications
2
Article number 6EP3330-6SB00-0AY0 6EP3331-6SB00-0AY0 6EP3332-6SB00-0AY0 6EP3333-6SB00-0AY0
Product LOGO!Power LOGO!Power LOGO!Power LOGO!Power
Power supply, type 24 V/0.6 A 24 V/1.3 A 24 V/2.5 A 24 V/4 A
environmental conditions
ambient temperature
• during operation -25 ... +70 °C -25 ... +70 °C -25 ... +70 °C -25 ... +70 °C
- Note with natural convection with natural convection with natural convection with natural convection
• during transport -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
• during storage -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
Humidity class according to Climate class 3K3, 5 … 95% Climate class 3K3, 5 … 95% Climate class 3K3, 5 … 95% Climate class 3K3, 5 … 95%
EN 60721 no condensation no condensation no condensation no condensation
Mechanics
Connection technology screw-type terminals screw-type terminals screw-type terminals screw-type terminals
Connections
• Supply input L, N: 1 screw terminal L, N: 1 screw terminal L, N: 1 screw terminal L, N: 1 screw terminal
each for 0.5 ... 2.5 mm² each for 0.5 ... 2.5 mm² each for 0.5 ... 2.5 mm² each for 0.5 ... 2.5 mm²
single-core/finely stranded single-core/finely stranded single-core/finely stranded single-core/finely stranded
• Output +, -: 1 screw terminal each +, -: 1 screw terminal each +, -: 1 screw terminal each +, -: 1 screw terminal each
for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm²
• Auxiliary - - - -
width of the enclosure 18 mm 36 mm 54 mm 72 mm
height of the enclosure 90 mm 90 mm 90 mm 90 mm
depth of the enclosure 53 mm 53 mm 53 mm 53 mm
required spacing
• top 20 mm 20 mm 20 mm 20 mm
• bottom 20 mm 20 mm 20 mm 20 mm
• left 0 mm 0 mm 0 mm 0 mm
• right 0 mm 0 mm 0 mm 0 mm
Weight, approx. 0.07 kg 0.12 kg 0.2 kg 0.29 kg
product feature of the enclosure Yes Yes Yes Yes
housing can be lined up
Installation Snaps onto DIN rail Snaps onto DIN rail Snaps onto DIN rail Snaps onto DIN rail
EN 60715 35x7.5/15, EN 60715 35x7.5/15, EN 60715 35x7.5/15, EN 60715 35x7.5/15,
direct mounting in different direct mounting in different direct mounting in different direct mounting in different
mounting positions mounting positions mounting positions mounting positions
MTBF at 40 °C 4 415 040 h 3 094 996 h 2 864 520 h 2 391 480 h
other information Specifications at rated Specifications at rated Specifications at rated Specifications at rated
input voltage and ambient input voltage and ambient input voltage and ambient input voltage and ambient
temperature +25 °C temperature +25 °C temperature +25 °C temperature +25 °C
(unless otherwise specified) (unless otherwise specified) (unless otherwise specified) (unless otherwise specified)
2
SIPLUS LOGO!Power 24 V 1.3 A 6AG1331-6SB00-7AY0
Extended temperature range and
exposure to media
Input 100 ... 240 V AC
Output 24 V DC, 1.3 A
SIPLUS LOGO!Power 24 V 2.5 A 6AG1332-6SB00-7AY0
Extended temperature range and
exposure to media
Input 100 ... 240 V AC
Output 24 V DC, 2.5 A
SIPLUS LOGO!Power 24 V 4 A 6AG1333-6SB00-7AY0
Extended temperature range and
exposure to media
Thanks to its stepped profile design, the SIPLUS LOGO!Power Input 100 ... 240 V AC
Output 24 V DC, 4 A
product family is ideally suited for low installation depths, such
as in miniature distribution boards. The stabilized power sup-
plies with a wide range input of 100 … 240 V AC (85 … 264 V)
and 110 ... 300 V DC are available with an output voltage of 24 V
in four performance classes. The 24 V versions are ideal for
supplying SIPLUS LOGO! controllers with the corresponding
voltage input. The high level of efficiency across the entire load
range as well as the low no-load losses result in lower overall
energy consumption. Greater convenience when commission-
ing and servicing thanks to integrated current monitor
(for devices at least 36 mm wide). The extended temperature
range enables a host of additional applications.
Main product highlights
• 24 V DC / 0.6 A, 1.3 A, 2.5 A and 4.0 A
• Narrow unit with width of 18 mm, 36 mm, 54 mm or 72 mm and
overall depth of 53 mm in LOGO! design
• Flexible mounting: top hat DIN rail or wall mounting in a range
of
installation positions
• Higher energy efficiency: up to 90% efficiency over the entire
load range as well as no-load power losses of < 0.3 W
• Integrated current monitor: Actual output current
measurement directly at the power supply unit
(for devices at least 36 mm wide)
• Global use: International certifications such as UL, CSA, FM or
ATEX
■ Technical specifications
2
Article number 6AG1331-6SB00-7AY0 6AG1332-6SB00-7AY0 6AG1333-6SB00-7AY0
Based on 6EP3331-6SB00-0AY0 6EP3332-6SB00-0AY0 6EP3333-6SB00-0AY0
Product SIPLUS LOGO!Power SIPLUS LOGO!Power SIPLUS LOGO!Power
Power supply, type 24 V/1.3 A 24 V/2.5 A 24 V/4 A
environmental conditions
ambient temperature in horizontal -40; Startup @ -25 °C ... +70; -40; Startup @ -25 °C ... +70; -40; Startup @ -25 °C ... +70;
mounting position during operation with natural convection with natural convection with natural convection
minimum
ambient temperature in horizontal
mounting position during operation
maximum
ambient temperature during storage -40 ... +85 -40 ... +85 -40 ... +85
and transport
installation altitude at height above 6 000 m 6 000 m 6 000 m
sea level maximum
ambient condition relating to In case of operation at altitudes of In case of operation at altitudes of In case of operation at altitudes of
ambient temperature - air pressure - 2000 - 6000 m above sea level: Output 2000 - 6000 m above sea level: Output 2000 - 6000 m above sea level: Output
installation altitude power derating of -7.5 %/1000 m or power derating of -7.5 %/1000 m or power derating of -7.5 %/1000 m or
reduction of the ambient temperature reduction of the ambient temperature reduction of the ambient temperature
by 5 K/1000 m by 5 K/1000 m by 5 K/1000 m
relative humidity with condensation 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
acc. to IEC 60068-2-38 maximum (no commissioning if condensation is (no commissioning if condensation is (no commissioning if condensation is
present), horizontal installation present), horizontal installation present), horizontal installation
chemical resistance to commercially Yes; incl. diesel and oil droplets in the Yes; incl. diesel and oil droplets in the Yes; incl. diesel and oil droplets in the
available cooling lubricants air air air
resistance to biologically active Yes; Class 3B2 mold, fungal, sponge Yes; Class 3B2 mold, fungal, sponge Yes; Class 3B2 mold, fungal, sponge
substances conformity acc. to spores (except fauna); class 3B3 upon spores (except fauna); class 3B3 upon spores (except fauna); class 3B3 upon
EN 60721-3-3 request request request
resistance to chemically active Yes; Class 3C4 (RH < 75%) incl. Yes; Class 3C4 (RH < 75%) incl. Yes; Class 3C4 (RH < 75%) incl.
substances conformity acc. to salt spray acc. to EN 60068-2-52 salt spray acc. to EN 60068-2-52 salt spray acc. to EN 60068-2-52
EN 60721-3-3 (severity level 3) (severity level 3) (severity level 3)
resistance to mechanically active Yes; Class 3S4 incl. sand, dust Yes; Class 3S4 incl. sand, dust Yes; Class 3S4 incl. sand, dust
substances conformity acc. to
EN 60721-3-3
resistance to biologically active Yes; Class 6B2 mold, fungal, sponge Yes; Class 6B2 mold, fungal, sponge Yes; Class 6B2 mold, fungal, sponge
substances conformity acc. to spores (except fauna) spores (except fauna) spores (except fauna)
EN 60721-3-6
resistance to chemically active Yes; Class 6C3 (RH < 75%) incl. Yes; Class 6C3 (RH < 75%) incl. Yes; Class 6C3 (RH < 75%) incl.
substances conformity acc. to salt spray acc. to EN 60068-2-52 salt spray acc. to EN 60068-2-52 salt spray acc. to EN 60068-2-52
EN 60721-3-6 (severity level 3) (severity level 3) (severity level 3)
resistance to mechanically active Yes; Class 6S3 incl. sand, dust Yes; Class 6S3 incl. sand, dust Yes; Class 6S3 incl. sand, dust
substances conformity acc. to
EN 60721-3-6
coating for equipped printed circuit Yes; Class 2 for high availability Yes; Class 2 for high availability Yes; Class 2 for high availability
board acc. to EN 61086
type of coating protection against Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
pollution according to EN 60664-3
type of test of the coating acc. to Yes; Discoloration of the coating during Yes; Discoloration of the coating during Yes; Discoloration of the coating during
MIL-I-46058C service life possible service life possible service life possible
product conformity of the coating Yes; Conformal Coating, Class A Yes; Conformal Coating, Class A Yes; Conformal Coating, Class A
Qualification and Performance of
Electrical Insulating Compound for
Printed Board Assemblies acc. to
IPC-CC-830A
2
LOGO!Soft Comfort V8 6ED1058-0BA08-0YA1
for programming on the PC
in LAD/FBD;
executes on Windows 8, 7, XP,
Linux and Mac OSX; on DVD
2
LOGO! Starter Kits
In TANOS Box,
with LOGO! Soft Comfort V8,
WinCC Basic, Ethernet cable
LOGO! Starter Kit 12/24RCE 6ED1057-3BA01-0AA8
With LOGO! 12/24RCE,
power supply, screwdriver,
in Systainer
LOGO! Starter Kit 130 RCE 6ED1057-3BA03-0AA8
With LOGO! 230RCE,
power supply, screwdriver,
in Systainer
LOGO! Starter Kit 12/24 V 6ED1057-3BA11-0AA8
With LOGO! 12/24RCEO,
LOGO! TD, power supply,
screwdriver, in Systainer
There are now six LOGO! 8 Starter Kits for price-conscious LOGO! 8 KP300 Basic Starter Kit 6AV2132-0HA00-0AA1
beginners – each individually configured for the specific With LOGO! 12/24RCE,
requirements. LOGO! Power 24 V 1.3 A,
• LOGO! Starter Kit 12/24RCE; KP300 Basic mono PN
With LOGO! 12/24RCE, power supply, screwdriver, LOGO! 8 KTP400 Basic Starter Kit 6AV2132-0KA00-0AA1
in Systainer With LOGO! 12/24RCE,
• LOGO! Starter Kit 130 RCE; LOGO! Power 24 V 1.3 A,
With LOGO! 230RCE, power supply, screwdriver, KTP400 Basic
in Systainer LOGO! 8 KTP700 Basic Starter Kit 6AV2132-3GB00-0AA1
• LOGO! Starter Kit 12/24 V; With LOGO! 12/24RCE,
With LOGO! 12/24RCEO, LOGO! TD, power supply, LOGO! Power 24 V 1.3 A,
screwdriver, in Systainer KTP700 Basic
2
LOGO!Contact
Switching module for
direct switching of resistive loads
up to 20 A and motors up to 4 kW
Switching voltage 24 V 6ED1057-4CA00-0AA0
Switching voltage 230 V 6ED1057-4EA00-0AA0
■ Technical specifications
Article number 6ED1057-4CA00-0AA0 6ED1057-4EA00-0AA0
LOGO! Contact Mod., DC 24V, 3NO/1NC LOGO! Contact Mod., AC 230V,3NO/1NC
Standards, approvals, certificates
CE mark Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -25 °C -25 °C
• max. 55 °C 55 °C
Dimensions
Width 36 mm 36 mm
Height 72 mm 72 mm
Depth 55 mm 55 mm
Weights
Weight, approx. 160 g 160 g
2
Front panel mounting kit
Width 4 MW, with keys 6AG1057-1AA00-0AA3
Width 8 MW, with keys 6AG1057-1AA00-0AA2
LOGO! and SIPLUS LOGO! are designed for quick and easy
mounting on top hat DIN rails. With the mounting kit, these de-
vices can also be easily and safely installed in front panels. If the
supplied washer and seals are used, the devices are reliably
protected against harsh environmental conditions up to the IP65
degree of protection.
■ Overview
The wiring of the
• SIMATIC S7-1500 IO (25 mm) 2
• SIMATIC ET 200SP
• SIMATIC S7-1200
• LOGO!
with the sensors/actuators is a significant factor with respect to
time/cost overhead during configuration, control cabinet design,
procurement and ease of servicing. The SIMATIC TOP connect
system cabling makes connection easy, fast and secure.
■ Design
The unshielded universal connecting cable is offered for a wide • 16-pin ID (insulation displacement) connector for connection
range of control cabinet concepts. to the SIMATIC TOP connect terminal modules for 8 I/Os:
- 3-wire connection using the appropriate terminal module for
It comprises: quick, error-free wiring
• 16-pin round cable with a core diameter of 0.14 mm2, - Galvanic isolation and adaptation using a coupling relay
pre-assembled with wire end ferrules for connection to the for easy implementation of potential groups in the system
controller: - High output current (up to 4 A), even for higher switching
- labeled with "0" … "7" for the control inputs/outputs frequencies, using an optocoupler module (overload and
- labeled with "M" for mass short-circuit proof)
- labeled with "L+" for 24 V DC potential - Implementation of isolating terminals using switch modules
enabling individual signals to be measured
- Channel-wise protection of I/Os using a fuse module with a
thermal fuse
SIMATIC S7-1500,
I/O module (25 mm) incl.
front connector module
Siemens ST 70 · 2021
© Siemens 2021
■ Overview
• Compact controllers for the low to mid-performance ranges
• Large-scale integration, space-saving, powerful
• With exceptional real-time performance and powerful
communication options:
3 - Controller with integrated PROFINET IO controller interface
for communication between SIMATIC controllers, HMI,
programming device or other automation components
• All CPUs can be used in stand-alone mode, in networks and
within distributed structures
• Extremely simple installation, programming and operation
• Integrated web server with standard and user-specific
web pages
• Data logging functionality for archiving of data at runtime from
the user program
• Powerful, integrated technology functions such as counting,
measuring, closed-loop control, and Motion Control
• Integrated digital and analog inputs/outputs
• Flexible expansion facilities
- Signal boards for direct use in a controller
- Signal modules for expansion of controllers with input/output
channels;
including an Energy Meter module for recording and
preparing energy data
- Accessories, e.g. power supply, switch module or
SIMATIC memory card
■ Technical specifications
General technical specifications SIMATIC S7-1200 General technical data of SIPLUS S7-1200
Degree of protection IP20 acc. to IEC 529 Ambient temperature range -40/-25/-20 ... +55/+60/+70 °C
Ambient temperature Conformal coating Coating of the printed circuit boards
• Operation and the electronic components
(95% humidity)
- Horizontal installation -20 ... +60 °C
Technical specifications The technical specifications of the
standard product apply except for
3
- Vertical installation -20 ... +50 °C the ambient conditions.
• Transportation and storage -40 ... +70 °C Ambient conditions
- With 95% humidity 25 ... 55 °C
Extended range of environmental
Insulation conditions
• 5/24 V DC circuits 500 V AC test voltage • with reference to ambient Tmin ... Tmax at
• 115/230 V AC circuits to ground 1500 V AC test voltage temperature, air pressure and 1080 hPa ... 795 hPa
• 115/230 V AC circuits to 1500 V AC test voltage altitude (-1000 m ... +2000 m) //
115/230 V AC circuits Tmin ... (Tmax - 10K) at
795 hPa ... 658 hPa
• 230 V AC circuits to 1500 V AC test voltage
(+2000 m ... +3500 m) //
5/24 V DC circuits
Tmin ... (Tmax - 20K) at
• 115 V AC circuits to 1500 V AC test voltage 658 hPa ... 540 hPa
5/24 V DC circuits (+3500 m ... +5000 m)
Electromagnetic compatibility Requirements of the EMC directive • At cold restart, min. 0° C
• Noise immunity acc. to Test acc. to: Relative humidity
EN 50082-2 IEC 801-2, IEC 801-3, IEC 801-4,
• with condensation, max. 100 %; RH incl. bedewing/frost
EN 50141, EN 50204, IEC 801-5,
(no commissioning in bedewed state)
VDE 0160
• Emitted interference acc. to Test according to Resistance
EN 50081-1 and EN 55011, Class A, • to biologically active Yes; Class 3B2 mold and fungal
EN 50081-2 Group 1 substances/compliance with spores (except fauna); the supplied
EN 60721-3-3 plug covers must remain in place on
Mechanical strength
the unused interfaces during
• Vibrations, test acc. to / tested with IEC 68, Part 2-6: operation.
10 ... 57 Hz;
• to chemically active Yes; Class 3C4 (RH < 75%) incl.
constant amplitude
substances/compliance with salt spray in accordance with
0.3 mm;
EN 60721-3-3 EN 60068-2-52 (severity 3);
58 ... 150 Hz;
the supplied plug covers must remain
constant acceleration
in place on the unused interfaces
1 g (mounted on DIN rail) or
during operation.
2 g (mounted in switchboard);
mode of vibration: • to mechanically active substances, Yes; Class 3S4 incl. sand, dust;
frequency sweeps with a sweep compliance with EN 60721-3-3 the supplied plug covers must remain
rate of 1 octave/minute; in place on unused interfaces during
duration of vibration: operation.
10 frequency sweeps per axis in
each direction of the three mutually
perpendicular axes
• Shocks, test acc. to / tested with IEC 68, Part 2-27/half-sine:
magnitude of shock 15 g
(peak value), duration 11 ms,
6 shocks in each of the three mutually
perpendicular axes
■ Overview
• Controller for intro to S7
• Expandable by:
- 1 signal board (SB), battery board (BB) or communication
board (CB)
3 - Max. 3 communications modules (CM)
3
battery (CR1025) is not included in Front flap set (spare part)
scope of supply
For CPU 1211C/1212C 6ES7291-1AA30-0XA0
Digital input simulator
Simulator Module SIM 1274 STEP 7 Professional / Basic V17
(optional)
Target system:
8 input switches, for CPU 1211C / 6ES7274-1XF30-0XA0 SIMATIC S7-1200, S7-1500,
CPU 1212C S7-300, S7-400, WinAC
Analog input simulator Requirement:
Simulator Module SIM 1274 Windows 10 (64-bit)
(optional) • Windows 10 Home Version 1909,
2004, 20H2 (only STEP 7 Basic)
2 potentiometers 6ES7274-1XA30-0XA0 • Windows 10 Professional Version
1909, 2004, 20H2
SIMATIC Memory Card (optional) • Windows 10 Enterprise Version
4 MB 6ES7954-8LC03-0AA0 1909, 2004, 20H2
• Windows 10 IoT Enterprise 2016
12 MB 6ES7954-8LE03-0AA0 LTSB
24 MB 6ES7954-8LF03-0AA0 • Windows 10 IoT Enterprise 2019
LTSC
256 MB 6ES7954-8LL03-0AA0 Windows Server (64-bit)
• Windows Server 2016 Standard
2 GB 6ES7954-8LP03-0AA0 (full installation)
32 GB 6ES7954-8LT03-0AA0 • Windows Server 2019 Standard
(full installation)
Terminal block (spare part)
Type of delivery:
For CPU 1211C AC/DC/relay 9 languages: de, en, zh included,
• For DI, 14-pin, tin-coated, coded; fr, sp, it, ru, jp, kr as download
4 units STEP 7 Professional V17, 6ES7822-1AA07-0YA5
- Screw-type system 6ES7292-1AP40-0XA0 floating license
- Push-in system 6ES7292-2AP40-0XA0 STEP 7 Professional V17, 6ES7822-1AE07-0YA5
• For DO, 8-pin, tin-coated, coded; floating license,
4 units software download including
- Screw-type system 6ES7292-1AH40-0XA0 license key 1)
- Push-in system 6ES7292-2AH40-0XA0 Email address required for delivery
• For AI, 3-pin, gold-plated; 4 units
STEP 7 Basic V17, floating license 6ES7822-0AA07-0YA5
- Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0 STEP 7 Basic V17, floating license, 6ES7822-0AE07-0YA5
software download including
For CPU 1211C DC/DC/DC license key1)
• For DI, 14-pin, tin-coated; 4 units Email address required for delivery
- Screw-type system 6ES7292-1AP30-0XA0
- Push-in system 6ES7292-2AP30-0XA0
• For DO, 8-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AH30-0XA0
- Push-in system 6ES7292-2AH30-0XA0
• For AI, 3-pin, gold-plated; 4 units
- Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
For CPU 1211C DC/DC/relay
• For DI, 14-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AP30-0XA0
- Push-in system 6ES7292-2AP30-0XA0
• For DO, 8-pin, tin-coated, coded;
4 units
- Screw-type system 6ES7292-1AH40-0XA0
- Push-in system 6ES7292-2AH40-0XA0
• For AI, 3-pin, gold-plated; 4 units
- Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
1) For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7211-1HE40-0XB0 6ES7211-1BE40-0XB0 6ES7211-1AE40-0XB0
CPU 1211C, DC/DC/Relay, CPU 1211C, AC/DC/Relay, CPU 1211C, DC/DC/DC, 6DI/4DO/2AI
6DI/4DO/2AI 6DI/4DO/2AI
General information
• Programming package STEP 7 V17 or higher STEP 7 V17 or higher STEP 7 V17 or higher
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes
Rated value (AC)
• 120 V AC Yes
• 230 V AC Yes
Encoder supply
24 V encoder supply
• 24 V L+ minus 4 V DC min. 20.4 to 28.8V L+ minus 4 V DC min.
Memory
Work memory
• integrated 50 kbyte 50 kbyte 50 kbyte
Load memory
• integrated 1 Mbyte 1 Mbyte 1 Mbyte
• Plug-in (SIMATIC Memory Card), with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
max.
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / instruction 0.08 µs; / instruction 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
Data areas and their retentivity
Flag
• Size, max. 4 kbyte; Size of bit memory address 4 kbyte; Size of bit memory address 4 kbyte; Size of bit memory address
area area area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Digital inputs
Number of digital inputs 6; Integrated 6; Integrated 6; Integrated
• of which inputs usable 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
for technological functions
Digital outputs
Number of digital outputs 4; Relays 4; Relays 4
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Number of analog inputs 2 2 2
Input ranges
• Voltage Yes Yes Yes
Analog outputs
Number of analog outputs 0 0 0
1. Interface
Protocols
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Yes; Yes;
Optionally also encrypted Optionally also encrypted Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy No No No
■ Technical specifications
Article number 6ES7211-1HE40-0XB0 6ES7211-1BE40-0XB0 6ES7211-1AE40-0XB0
CPU 1211C, DC/DC/Relay, CPU 1211C, AC/DC/Relay, CPU 1211C, DC/DC/DC, 6DI/4DO/2AI
6DI/4DO/2AI 6DI/4DO/2AI
Protocols
Open IE communication
• TCP/IP Yes Yes Yes
3
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
OPC UA
• OPC UA Server Yes; Yes; Yes;
data access (read, write, subscribe), data access (read, write, subscribe), Data access (read, write, subscribe),
method call, runtime license required method call, runtime license required runtime license required
Communication functions
S7 communication
• supported Yes Yes Yes
Integrated Functions
Frequency measurement Yes Yes Yes
controlled positioning Yes Yes Yes
Number of position-controlled 8 8 8
positioning axes, max.
Number of positioning axes via Up to 4 with SB 1222 Up to 4 with SB 1222 4; With integrated outputs
pulse-direction interface
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free RH < 60% condensation-free
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 90 mm 90 mm 90 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 380 g 420 g 370 g
■ Overview
• Controller for intro to S7 with basic expansion options
• Expandable by:
- 1 signal board (SB), battery board (BB)
or communication board (CB)
3 - 2 signal modules (SM)
- Max. 3 communications modules (CM)
3
CPU 1212C - Push-in system 6ES7292-2BC30-0XA0
Analog input simulator For CPU 1212C DC/DC/DC
Simulator Module SIM 1274 • For DI, 14-pin, tin-coated; 4 units
(optional)
- Screw-type system 6ES7292-1AP30-0XA0
2 potentiometers 6ES7274-1XA30-0XA0 - Push-in system 6ES7292-2AP30-0XA0
SIMATIC Memory Card (optional) • For DO, 8-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AH30-0XA0
4 MB 6ES7954-8LC03-0AA0
- Push-in system 6ES7292-2AH30-0XA0
12 MB 6ES7954-8LE03-0AA0 • For AI, 3-pin, gold-plated; 4 units
24 MB 6ES7954-8LF03-0AA0 - Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
256 MB 6ES7954-8LL03-0AA0
For CPU 1212C DC/DC/relay
2 GB 6ES7954-8LP03-0AA0
• For DI, 14-pin, tin-coated; 4 units
32 GB 6ES7954-8LT03-0AA0 - Screw-type system 6ES7292-1AP30-0XA0
Extension cable for two-tier 6ES7290-6AA30-0XA0 - Push-in system 6ES7292-2AP30-0XA0
configuration • For DO, 8-pin, tin-coated, coded;
4 units
For connecting digital/analog signal
- Screw-type system 6ES7292-1AH40-0XA0
modules;
length 2 m - Push-in system 6ES7292-2AH40-0XA0
• For AI, 3-pin, gold-plated; 4 units
Starter Kit CPU 1212C 6ES7212-1BE34-4YB0
AC/DC/relay - Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
Complete offer SIMATIC S7-1200,
starter box, comprising: RJ45 cable grip
CPU 1212C AC/DC/relay, simulator, 4 units per pack
STEP 7 BASIC, manual CD,
SIMATIC OPC UA S7-1200 Basic Single port 6ES7290-3AA30-0XA0
Runtime license, info material,
in Systainer Front flap set (spare part)
■ Technical specifications
Article number 6ES7212-1AE40-0XB0 6ES7212-1BE40-0XB0 6ES7212-1HE40-0XB0
CPU 1212C ,DC/DC/DC, 8DI/6DO/2AI CPU 1212C, AC/DC/Relay, 8DI/6DO/2AI CPU 1212C, DC/DC/Relay, 8DI/6DO/2AI
General information
Product type designation CPU 1212C DC/DC/DC CPU 1212C AC/DC/relay CPU 1212C DC/DC/relay
3 Engineering with
• Programming package STEP 7 V17 or higher STEP 7 V17 or higher STEP 7 V17 or higher
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes
Rated value (AC)
• 120 V AC Yes
• 230 V AC Yes
Encoder supply
24 V encoder supply
• 24 V L+ minus 4 V DC min. 20.4 to 28.8V L+ minus 4 V DC min.
Memory
Work memory
• integrated 75 kbyte 75 kbyte 75 kbyte
Load memory
• integrated 2 Mbyte 2 Mbyte 2 Mbyte
• Plug-in (SIMATIC Memory Card), with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
max.
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / instruction 0.08 µs; / instruction 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
Data areas and their retentivity
Flag
• Size, max. 4 kbyte; Size of bit memory address area 4 kbyte; Size of bit memory address area 4 kbyte; Size of bit memory address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Digital inputs
Number of digital inputs 8; Integrated 8; Integrated 8; Integrated
• of which inputs usable for 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
technological functions
Digital outputs
Number of digital outputs 6 6; Relays 6; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Number of analog inputs 2 2 2
Input ranges
• Voltage Yes Yes Yes
Analog outputs
Number of analog outputs 0 0 0
1. Interface
Protocols
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Yes; Yes;
Optionally also encrypted Optionally also encrypted Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy No No No
■ Technical specifications
Article number 6ES7212-1AE40-0XB0 6ES7212-1BE40-0XB0 6ES7212-1HE40-0XB0
CPU 1212C ,DC/DC/DC, 8DI/6DO/2AI CPU 1212C, AC/DC/Relay, 8DI/6DO/2AI CPU 1212C, DC/DC/Relay, 8DI/6DO/2AI
Protocols
Open IE communication
• TCP/IP
• ISO-on-TCP (RFC1006)
Yes
Yes
Yes
Yes
Yes
Yes
3
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
OPC UA
• OPC UA Server Yes; Yes; Yes;
data access (read, write, subscribe), data access (read, write, subscribe), data access (read, write, subscribe),
method call, runtime license required method call, runtime license required method call, runtime license required
Communication functions
S7 communication
• supported Yes Yes Yes
Integrated Functions
Frequency measurement Yes Yes Yes
controlled positioning Yes Yes Yes
Number of position-controlled 8 8 8
positioning axes, max.
Number of positioning axes via 4; With integrated outputs Up to 4 with SB 1222 Up to 4 with SB 1222
pulse-direction interface
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C; Number of simultaneously 60 °C; Number of simultaneously 60 °C; Number of simultaneously
activated inputs or outputs 4 or 3 activated inputs or outputs 4 or 3 activated inputs or outputs 4 or 3
(no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal
or 50 °C vertical, 8 or 6 at 55 °C or 50 °C vertical, 8 or 6 at 55 °C or 50 °C vertical, 8 or 6 at 55 °C
horizontal or 45 °C vertical horizontal or 45 °C vertical horizontal or 45 °C vertical
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free RH < 60% condensation-free
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 90 mm 90 mm 90 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 370 g 425 g 385 g
■ Overview
• Controller for intro to S7 with flexible expansion options
• Expandable by:
- 1 signal board (SB), battery board (BB)
or communication board (CB)
3 - 8 signal modules (SM)
- Max. 3 communications modules (CM)
3
CPU 1214C/1215C Front flap set (spare part)
Analog input simulator For CPU 1214C 6ES7291-1AB30-0XA0
Simulator Module SIM 1274
(optional) STEP 7 Professional / Basic V17
2 potentiometers 6ES7274-1XA30-0XA0 Target system:
SIMATIC S7-1200, S7-1500,
SIMATIC Memory Card (optional) S7-300, S7-400, WinAC
4 MB 6ES7954-8LC03-0AA0 Requirement:
Windows 10 (64-bit)
12 MB 6ES7954-8LE03-0AA0 • Windows 10 Home Version 1909,
24 MB 6ES7954-8LF03-0AA0 2004, 20H2 (only STEP 7 Basic)
• Windows 10 Professional Version
256 MB 6ES7954-8LL03-0AA0 1909, 2004, 20H2
2 GB 6ES7954-8LP03-0AA0 • Windows 10 Enterprise Version
1909, 2004, 20H2
32 GB 6ES7954-8LT03-0AA0 • Windows 10 IoT Enterprise 2016
LTSB
Extension cable for two-tier 6ES7290-6AA30-0XA0 • Windows 10 IoT Enterprise 2019
configuration LTSC
For connecting digital/analog signal Windows Server (64-bit)
modules; length 2 m • Windows Server 2016 Standard
(full installation)
Terminal block (spare part) • Windows Server 2019 Standard
(full installation)
For CPU 1214C AC/DC/relay
• For DI, 20-pin, tin-coated, coded; Type of delivery:
4 units 9 languages: de, en, zh included,
fr, sp, it, ru, jp, kr as download
- Screw-type system 6ES7292-1AV40-0XA0
- Push-in system 6ES7292-2AV40-0XA0 STEP 7 Professional V17, 6ES7822-1AA07-0YA5
• For DO, 12-pin, tin-coated, coded; floating license
4 units STEP 7 Professional V17, 6ES7822-1AE07-0YA5
- Screw-type system 6ES7292-1AM40-0XA0 floating license,
- Push-in system 6ES7292-2AM40-0XA0 software download including
• For AI, 3-pin, gold-plated; 4 units license key 1)
- Screw-type system 6ES7292-1BC30-0XA0 Email address required for delivery
- Push-in system 6ES7292-2BC30-0XA0 STEP 7 Basic V17, floating license 6ES7822-0AA07-0YA5
For CPU 1214C DC/DC/DC STEP 7 Basic V17, floating license, 6ES7822-0AE07-0YA5
• For DI, 20-pin, tin-coated; 4 units software download including
- Screw-type system 6ES7292-1AV30-0XA0 license key1)
- Push-in system 6ES7292-2AV30-0XA0 Email address required for delivery
• For DO, 12-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AM30-0XA0
- Push-in system 6ES7292-2AM30-0XA0
• For AI, 3-pin, gold-plated; 4 units
- Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
For CPU 1214C DC/DC/relay
• For DI, 20-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AV30-0XA0
- Push-in system 6ES7292-2AV30-0XA0
• For DO, 12-pin, tin-coated, coded;
4 units
- Screw-type system 6ES7292-1AM40-0XA0
- Push-in system 6ES7292-2AM40-0XA0
• For AI, 3-pin, gold-plated; 4 units
- Screw-type system 6ES7292-1BC30-0XA0
- Push-in system 6ES7292-2BC30-0XA0
1) For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7214-1BG40-0XB0 6ES7214-1AG40-0XB0 6ES7214-1HG40-0XB0
CPU 1214C, AC/DC/Relay, CPU 1214C, DC/DC/DC, CPU 1214C, DC/DC/Relay,
14DI/10DO/2AI 14DI/10DO/2AI 14DI/10DO/2AI
General information
• Programming package STEP 7 V17 or higher STEP 7 V17 or higher STEP 7 V17 or higher
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes
Rated value (AC)
• 120 V AC Yes
• 230 V AC Yes
Encoder supply
24 V encoder supply
• 24 V 20.4 to 28.8V L+ minus 4 V DC min. L+ minus 4 V DC min.
Memory
Work memory
• integrated 100 kbyte 100 kbyte 100 kbyte
Load memory
• integrated 4 Mbyte 4 Mbyte 4 Mbyte
• Plug-in (SIMATIC Memory Card), with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
max.
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / instruction 0.08 µs; / instruction 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
Data areas and their retentivity
Flag
• Size, max. 8 kbyte; Size of bit memory address area 8 kbyte; Size of bit memory address area 8 kbyte; Size of bit memory address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Digital inputs
Number of digital inputs 14; Integrated 14; Integrated 14; Integrated
• of which inputs usable for 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
technological functions
Digital outputs
Number of digital outputs 10; Relays 10 10; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Number of analog inputs 2 2 2
Input ranges
• Voltage Yes Yes Yes
Analog outputs
Number of analog outputs 0 0 0
1. Interface
Protocols
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Yes; Yes;
Optionally also encrypted Optionally also encrypted Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy No No No
■ Technical specifications
Article number 6ES7214-1BG40-0XB0 6ES7214-1AG40-0XB0 6ES7214-1HG40-0XB0
CPU 1214C, AC/DC/Relay, CPU 1214C, DC/DC/DC, CPU 1214C, DC/DC/Relay,
14DI/10DO/2AI 14DI/10DO/2AI 14DI/10DO/2AI
Protocols
Open IE communication
• TCP/IP Yes Yes Yes
3
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
OPC UA
• OPC UA Server Yes; Yes; Yes;
data access (read, write, subscribe), data access (read, write, subscribe), data access (read, write, subscribe),
method call, runtime license required method call, runtime license required method call, runtime license required
Communication functions
S7 communication
• supported Yes Yes Yes
Integrated Functions
Frequency measurement Yes Yes Yes
controlled positioning Yes Yes Yes
Number of position-controlled 8 8 8
positioning axes, max.
Number of positioning axes via Up to 4 with SB 1222 4; With integrated outputs Up to 4 with SB 1222
pulse-direction interface
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C; Number of simultaneously 60 °C; Number of simultaneously 60 °C; Number of simultaneously
activated inputs or outputs 7 or 5 activated inputs or outputs 7 or 5 activated inputs or outputs 7 or 5
(no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal
or 50 °C vertical, 14 or 10 at 55 °C or 50 °C vertical, 14 or 10 at 55 °C or 50 °C vertical, 14 or 10 at 55 °C
horizontal or 45 °C vertical horizontal or 45 °C vertical horizontal or 45 °C vertical
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free RH < 60% condensation-free
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 110 mm 110 mm 110 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 455 g 415 g 435 g
■ Overview
• Powerful controller with enhanced networking option
• Expandable by:
- 1 signal board (SB), battery board (BB)
or communication board (CB)
3 - 8 signal modules (SM)
- Max. 3 communications modules (CM)
3
battery (CR1025) is not included 4 units per pack
Digital input simulator Dual port 6ES7290-3AB30-0XA0
Simulator Module SIM 1274
(optional) STEP 7 Professional / Basic V17
14 input switches, for 6ES7274-1XH30-0XA0 Target system:
CPU 1214C/1215C SIMATIC S7-1200, S7-1500,
S7-300, S7-400, WinAC
Analog input simulator
Simulator Module SIM 1274 Requirement:
(optional) Windows 10 (64-bit)
• Windows 10 Home Version 1909,
2 potentiometers 6ES7274-1XA30-0XA0 2004, 20H2 (only STEP 7 Basic)
• Windows 10 Professional Version
SIMATIC Memory Card (optional) 1909, 2004, 20H2
4 MB 6ES7954-8LC03-0AA0 • Windows 10 Enterprise Version
1909, 2004, 20H2
12 MB 6ES7954-8LE03-0AA0 • Windows 10 IoT Enterprise 2016
24 MB 6ES7954-8LF03-0AA0 LTSB
• Windows 10 IoT Enterprise 2019
256 MB 6ES7954-8LL03-0AA0 LTSC
Windows Server (64-bit)
2 GB 6ES7954-8LP03-0AA0 • Windows Server 2016 Standard
32 GB 6ES7954-8LT03-0AA0 (full installation)
• Windows Server 2019 Standard
Extension cable for two-tier 6ES7290-6AA30-0XA0 (full installation)
configuration
Type of delivery:
For connecting digital/ 9 languages: de, en, zh included,
analog signal modules; fr, sp, it, ru, jp, kr as download
length 2 m STEP 7 Professional V17, 6ES7822-1AA07-0YA5
Terminal block (spare part) floating license
For CPU 1215C AC/DC/relay STEP 7 Professional V17, 6ES7822-1AE07-0YA5
• For DI, 20-pin, tin-coated, coded; floating license, software download
4 units including license key 1)
- Screw-type system 6ES7292-1AV40-0XA0 Email address required for delivery
- Push-in system 6ES7292-2AV40-0XA0 STEP 7 Basic V17, floating license 6ES7822-0AA07-0YA5
• For DO, 12-pin, tin-coated, coded;
4 units STEP 7 Basic V17, floating license, 6ES7822-0AE07-0YA5
software download including
- Screw-type system 6ES7292-1AM40-0XA0 license key1)
- Push-in system 6ES7292-2AM40-0XA0
Email address required for delivery
• For analog signals, 6-pin,
gold-plated; 4 units
- Screw-type system 6ES7292-1BF30-0XB0
- Push-in system 6ES7292-2BF30-0XB0
For CPU 1215C DC/DC/DC
• For DI, 20-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AV30-0XA0
- Push-in system 6ES7292-2AV30-0XA0
• For DO, 12-pin, tin-plated, coded;
tin-plated; 4 units
- Screw-type system 6ES7292-1AM30-0XA0
- Push-in system 6ES7292-2AM30-0XA0
• For analog signals, 6-pin,
gold-plated; 4 units
- Screw-type system 6ES7292-1BF30-0XB0
- Push-in system 6ES7292-2BF30-0XB0
For CPU 1215C DC/DC/relay
• For DI, 20-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AV30-0XA0
- Push-in system 6ES7292-2AV30-0XA0
• For DO, 12-pin, tin-coated, coded;
4 units
- Screw-type system 6ES7292-1AM40-0XA0
- Push-in system 6ES7292-2AM40-0XA0
• For analog signals, 6-pin,
gold-plated; 4 units
- Screw-type system 6ES7292-1BF30-0XB0
- Push-in system 6ES7292-2BF30-0XB0
1) For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7215-1AG40-0XB0 6ES7215-1BG40-0XB0 6ES7215-1HG40-0XB0
CPU 1215C, DC/DC/DC, CPU 1215C, AC/DC/RLY, CPU 1215C, DC/DC/RLY,
14DI/10DO/2AI/2AO 14DI/10DO/2AI/2AO 14DI/10DO/2AI/2AO
General information
• Programming package STEP 7 V17 or higher STEP 7 V17 or higher STEP 7 V17 or higher
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes
Rated value (AC)
• 120 V AC Yes
• 230 V AC Yes
Encoder supply
24 V encoder supply
• 24 V L+ minus 4 V DC min. 20.4 to 28.8V L+ minus 4 V DC min.
Memory
Work memory
• integrated 125 kbyte 125 kbyte 125 kbyte
Load memory
• integrated 4 Mbyte 4 Mbyte 4 Mbyte
• Plug-in (SIMATIC Memory Card), with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
max.
Backup
• without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / instruction 0.08 µs; / instruction 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
Data areas and their retentivity
Flag
• Size, max. 8 kbyte; Size of bit memory address area 8 kbyte; Size of bit memory address area 8 kbyte; Size of bit memory address area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Digital inputs
Number of digital inputs 14; Integrated 14; Integrated 14; Integrated
• of which inputs usable for 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
technological functions
Digital outputs
Number of digital outputs 10 10; Relays 10; Relays
• of which high-speed outputs 4; 100 kHz Pulse Train Output
Analog inputs
Number of analog inputs 2 2 2
Input ranges
• Voltage Yes Yes Yes
Analog outputs
Number of analog outputs 2 2 2
Output ranges, current
• 0 to 20 mA Yes Yes Yes
■ Technical specifications
Article number 6ES7215-1AG40-0XB0 6ES7215-1BG40-0XB0 6ES7215-1HG40-0XB0
CPU 1215C, DC/DC/DC, CPU 1215C, AC/DC/RLY, CPU 1215C, DC/DC/RLY,
14DI/10DO/2AI/2AO 14DI/10DO/2AI/2AO 14DI/10DO/2AI/2AO
1. Interface
Protocols
• PROFINET IO Controller Yes Yes Yes
3
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Yes; Yes;
Optionally also encrypted Optionally also encrypted Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy Yes Yes Yes
Protocols
Open IE communication
• TCP/IP Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes
• UDP Yes Yes Yes
Web server
• supported Yes Yes Yes
OPC UA
• OPC UA Server Yes; Yes; Yes;
data access (read, write, subscribe), data access (read, write, subscribe), data access (read, write, subscribe),
method call, runtime license required method call, runtime license required method call, runtime license required
Communication functions
S7 communication
• supported Yes Yes Yes
Integrated Functions
Frequency measurement Yes Yes Yes
controlled positioning Yes Yes Yes
Number of position-controlled 8 8 8
positioning axes, max.
Number of positioning axes via 4; With integrated outputs Up to 4 with SB 1222 Up to 4 with SB 1222
pulse-direction interface
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C; Number of simultaneously 60 °C; Number of simultaneously 60 °C; Number of simultaneously
activated inputs or outputs 7 or 5 activated inputs or outputs 7 or 5 activated inputs or outputs 7 or 5
(no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal (no adjacent points) at 60 °C horizontal
or 50 °C vertical, 14 or 10 at 55 °C or 50 °C vertical, 14 or 10 at 55 °C or 50 °C vertical, 14 or 10 at 55 °C
horizontal or 45 °C vertical horizontal or 45 °C vertical horizontal or 45 °C vertical
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free RH < 60% condensation-free
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- SCL Yes Yes Yes
Dimensions
Width 130 mm 130 mm 130 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 500 g 550 g 585 g
■ Overview
• Powerful controller for extremely fast signal processing
• Expandable by:
- 1 signal board (SB), battery board (BB)
or communication board (CB)
3 - 8 signal modules (SM)
- Max. 3 communications modules (CM)
■ Technical specifications
Article number 6ES7217-1AG40-0XB0 Article number 6ES7217-1AG40-0XB0
CPU 1217C, DC/DC/DC, CPU 1217C, DC/DC/DC,
14DI/10DQ/2AI/2AQ 14DI/10DQ/2AI/2AQ
General information Protocols
■ Overview
• The superior compact solution
• With 14 integral input/outputs
• Expandable with:
- 1 signal board (SB) or communication board (CB);
not possible with: 6AG1212-1AE40-2XB0,
6AG1212-1BE40-2XB0, 6AG1212-1HE40-2XB0 3
- 2 signal modules (SM)
- Max. 3 communications modules (CM)
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
3
with 6AG1212-1....-2XB0)
Integrated program/data memory
75 KB, load memory 1 MB; 2 inputs, 24 V DC,
Power supply 24 V DC; IEC type 1 sinking input;
Boolean execution times 2 transistor outputs 24 V DC,
0.1 μs per operation; 0.5 A, 5 W;
8 digital inputs, can be used as HSC at
6 digital outputs (relays), up to 30 kHz
2 analog inputs; • Suitable for areas with extreme 6AG1223-0BD30-4XB0
Expandable by up to exposure to media (conformal
3 communications modules, coating)
2 signal modules, and 1 signal • Ambient temperature 6AG1223-0BD30-5XB0
board/communication board; -25 ... +55 °C
Digital inputs can be used as HSC
at 100 kHz 2 inputs, 5 V DC, 200 kHz 6AG1223-3AD30-5XB0
• For areas with extreme exposure 6AG1212-1HE40-4XB0 2 outputs 5 V DC, 0.1 A, 200 kHz
to media (conformal coating); 2 inputs, 24 V DC, 200 kHz 6AG1223-3BD30-5XB0
ambient temperature 2 outputs 24 V DC, 0.1 A, 200 kHz
-20 ... +60 °C
• For areas with extreme exposure 6AG1212-1HE40-2XB0 SIPLUS SB 1232 analog output
to media (conformal coating); signal board
ambient temperature
(Extended temperature range and
-40 ... +70 °C
exposure to media; cannot be used
Accessories with 6AG1212-1....-2XB0)
SIPLUS SB 1221 digital input Ambient temperature range
signal board -25 ... +55 °C
(Extended temperature range and 1 analog output, ±10 V with 12 bits 6AG1232-4HA30-5XB0
exposure to media; cannot be used or 0 ... 20 mA with 11 bits
with 6AG1212-1....-2XB0)
Ambient temperature range
4 inputs, 5 V DC, 200 kHz, 6AG1221-3AD30-5XB0 0 ... +55 °C
sourcing input
1 analog output, ±10 V with 12 bits 6AG1232-4HA30-4XB0
4 inputs, 24 V DC, 200 kHz, 6AG1221-3BD30-5XB0 or 0 ... 20 mA with 11 bits
sourcing input
SIPLUS CB 1241 RS 485
SIPLUS SB 1222 digital output communication board
signal board
(Extended temperature range and
(Extended temperature range and exposure to media; cannot be used
exposure to media; cannot be used with 6AG1212-1....-2XB0)
with 6AG1212-1....-2XB0)
For point-to-point connection, 6AG1241-1CH30-5XB1
4 outputs, 5 V DC, 0.1 A, 200 kHz 6AG1222-1AD30-5XB0 with 1 RS 485 interface
4 outputs, 24 V DC, 0.1 A, 200 kHz 6AG1222-1BD30-5XB0 Additional accessories See SIMATIC S7-1200
CPU 1212C page 3/9
■ Technical specifications
Article number 6AG1212-1AE40-4XB0 6AG1212-1AE40-2XB0
Based on 6ES7212-1AE40-0XB0 6ES7212-1AE40-0XB0
SIPLUS S7-1200 CPU 1212C DC/DC/DC SIPLUS S7-1200 CPU 1212C DC/DC/DC
Ambient conditions
Ambient temperature
during operation
3
• min. -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
• max. 60 °C; Number of simultaneously activated inputs 70 °C; = Tmax; Tmax > +55 °C number of simultaneously
or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or switched-on digital inputs 4, digital outputs 3, analog inputs
50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical 2 (no adjacent points) with horizontal mounting position;
Tmax > +60 °C number of simultaneously switched-on
digital inputs 3, digital outputs 2, analog inputs 0
(no adjacent points) with horizontal mounting position
• At cold restart, min. 0 °C -25 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under condensation conditions) (no commissioning under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1212-1BE40-4XB0 6AG1212-1BE40-2XB0
Based on 6ES7212-1BE40-0XB0 6ES7212-1BE40-0XB0
SIPLUS S7-1200 CPU 1212C AC/DC/RLY SIPLUS S7-1200 CPU 1212C AC/DC/RLY
Ambient conditions
3 Ambient temperature during
operation
• min. -20 °C; = Tmin; Startup @ 0 °C -40 °C; = Tmin; Startup @ -25 °C
• max. 60 °C; Number of simultaneously activated inputs or 70 °C; = Tmax; Tmax > +55 °C number of simultaneously
outputs 4 or 3 (no adjacent points) at 60 °C horizontal or switched-on digital inputs 4, digital outputs 3, analog
50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical inputs 2 (no adjacent points) with horizontal mounting
position; Tmax > +60 °C number of simultaneously
switched-on digital inputs 3, digital outputs 2, analog
inputs 0 (no adjacent points) with horizontal mounting
position
• At cold restart, min. 0 °C -25 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC (+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under condensation conditions) (no commissioning under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1212-1HE40-4XB0 6AG1212-1HE40-2XB0
Based on 6ES7212-1HE40-0XB0 6ES7212-1HE40-0XB0
SIPLUS S7-1200 CPU 1212C DC/DC/RLY SIPLUS S7-1200 CPU 1212C DC/DC/RLY
Ambient conditions
Ambient temperature
during operation
3
• min. -20 °C; = Tmin; Startup @ 0 °C -40 °C; = Tmin; Startup @ -25 °C
• max. 60 °C; Number of simultaneously activated inputs or 70 °C; = Tmax; Tmax > +55 °C number of simultaneously
outputs 4 or 3 (no adjacent points) at 60 °C horizontal or switched-on digital inputs 4, digital outputs 3, analog
50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical inputs 2 (no adjacent points) with horizontal mounting
position; Tmax > +60 °C number of simultaneously
switched-on digital inputs 3, digital outputs 2, analog
inputs 0 (no adjacent points) with horizontal mounting
position
• At cold restart, min. 0 °C -25 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC (+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under condensation conditions) (no commissioning under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Overview
• The compact high-performance CPU
• With 24 integrated I/Os
• Expandable with:
- 1 signal board (SB) or communication board (CB);
3 not possible with: 6AG1214-1AG40-2XB0,
6AG1214-1BG40-2XB0, 6AG1214-1HG40-2XB0
- 8 signal modules (SM)
- Max. 3 communications modules (CM)
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
3
with 6AG1214-1....-2XB0)
Integrated program/data memory
100 KB, load memory 2 MB; 2 inputs, 24 V DC,
Power supply 24 V DC; IEC type 1 sinking input;
Boolean execution times 2 transistor outputs 24 V DC,
0.1 μs per operation; 0.5 A, 5 W;
14 digital inputs, can be used as HSC at
10 digital outputs (relays), up to 30 kHz
2 analog inputs; • Suitable for areas with 6AG1223-0BD30-4XB0
Expandable by up to extreme exposure to media
3 communications modules, (conformal coating)
8 signal modules, and 1 signal • Ambient temperature 6AG1223-0BD30-5XB0
board/communication board; -25 ... +55 °C
Digital inputs can be used as HSC
at 100 kHz 2 inputs, 5 V DC, 200 kHz 6AG1223-3AD30-5XB0
• For areas with extreme exposure 6AG1214-1HG40-4XB0 2 outputs 5 V DC, 0.1 A, 200 kHz
to media (conformal coating); 2 inputs, 24 V DC, 200 kHz 6AG1223-3BD30-5XB0
ambient temperature 2 outputs 24 V DC, 0.1 A, 200 kHz
-20 ... +60 °C
• For areas with extreme exposure 6AG1214-1HG40-5XB0 SIPLUS SB 1232 analog output
to media (conformal coating); signal board
ambient temperature
(Extended temperature range and
-40 ... +60 °C
exposure to media; cannot be used
• For areas with extreme exposure 6AG1214-1HG40-2XB0 with 6AG1214-1....-2XB0)
to media (conformal coating);
ambient temperature Ambient temperature range
-40 ... +70 °C -25 ... +55 °C
Accessories 1 analog output, ±10 V with 12 bits 6AG1232-4HA30-5XB0
or 0 ... 20 mA with 11 bits
SIPLUS SB 1221 digital input
signal board Ambient temperature range
0 ... +55 °C
(Extended temperature range and
exposure to media; cannot be used 1 analog output, ±10 V with 12 bits 6AG1232-4HA30-4XB0
with 6AG1214-1....-2XB0) or 0 ... 20 mA with 11 bits
4 inputs, 5 V DC, 200 kHz, 6AG1221-3AD30-5XB0 SIPLUS CB 1241 RS 485
sourcing input communication board
4 inputs, 24 V DC, 200 kHz, 6AG1221-3BD30-5XB0 (Extended temperature range and
sourcing input exposure to media; cannot be used
with 6AG1214-1....-2XB0)
SIPLUS SB 1222 digital output
signal board For point-to-point connection, 6AG1241-1CH30-5XB1
with 1 RS 485 interface
(Extended temperature range and
exposure to media; cannot be used Additional accessories See SIMATIC S7-1200
with 6AG1214-1....-2XB0) CPU 1214C page 3/13
4 outputs, 5 V DC, 0.1 A, 200 kHz 6AG1222-1AD30-5XB0
4 outputs, 24 V DC, 0.1 A, 200 kHz 6AG1222-1BD30-5XB0
■ Technical specifications
Article number 6AG1214-1AG40-4XB0 6AG1214-1AG40-5XB0 6AG1214-1AG40-2XB0
Based on 6ES7214-1AG40-0XB0 6ES7214-1AG40-0XB0 6ES7214-1AG40-0XB0
SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C
DC/DC/DC DC/DC/DC DC/DC/DC
3 Ambient conditions
Ambient temperature
during operation
• min. -20 °C; = Tmin; Startup @ 0 °C -40 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ -25 °C
• max. 60 °C; Number of simultaneously 60 °C; = Tmax; Tmax > +55 °C number 70 °C; = Tmax; Tmax > +55 °C number
activated inputs or outputs 7 or 5 (no of simultaneously switched-on digital of simultaneously switched-on digital
adjacent points) at 60 °C horizontal or inputs 7, digital outputs 5, analog inputs 7, digital outputs 5, analog
50 °C vertical, 14 or 10 at 55 °C inputs 2 (no adjacent points) with inputs 2 (no adjacent points) with
horizontal or 45 °C vertical horizontal mounting position horizontal mounting position; Tmax >
+60 °C number of simultaneously
switched-on digital inputs 7, digital
outputs 5, analog inputs 1 (no adjacent
points) with horizontal mounting
position
• At cold restart, min. 0 °C -25 °C -25 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
■ Technical specifications
Article number 6AG1214-1AG40-4XB0 6AG1214-1AG40-5XB0 6AG1214-1AG40-2XB0
Based on 6ES7214-1AG40-0XB0 6ES7214-1AG40-0XB0 6ES7214-1AG40-0XB0
SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C
DC/DC/DC DC/DC/DC DC/DC/DC
Usage in industrial process
technology 3
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1214-1BG40-4XB0 6AG1214-1BG40-5XB0 6AG1214-1BG40-2XB0
Based on 6ES7214-1BG40-0XB0 6ES7214-1BG40-0XB0 6ES7214-1BG40-0XB0
SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C
AC/DC/RLY AC/DC/RLY AC/DC/RLY
3 Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1214-1HG40-4XB0 6AG1214-1HG40-5XB0 6AG1214-1HG40-2XB0
Based on 6ES7214-1HG40-0XB0 6ES7214-1HG40-0XB0 6ES7214-1HG40-0XB0
SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C
DC/DC/RLY DC/DC/RLY DC/DC/RLY
Ambient conditions
Ambient temperature
3
during operation
• min. -20 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ 0 °C start-up @ -25 °C start-up @ -25 °C
• max. 60 °C; Number of simultaneously 60 °C; = Tmax; Tmax > +55 °C number 70 °C; = Tmax; Tmax > +55 °C number
activated inputs or outputs 7 or 5 of simultaneously switched-on digital of simultaneously switched-on digital
(no adjacent points) at 60 °C horizontal inputs 7, digital outputs 5, analog inputs 7, digital outputs 5, analog
or 50 °C vertical, 14 or 10 at 55 °C inputs 2 (no adjacent points) with inputs 2 (no adjacent points) with
horizontal or 45 °C vertical horizontal mounting position horizontal mounting position; Tmax >
+60 °C number of simultaneously
switched-on digital inputs 7, digital
outputs 5, analog inputs 1 (no adjacent
points) with horizontal mounting
position
• At cold restart, min. 0 °C -25 °C -25 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax - 20 K) at Tmin ... (Tmax - 20 K) at Tmin ... (Tmax - 20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m); (+3 500 m ... +5 000 m); (+3 500 m ... +5 000 m);
above 2 000 m max. 132 V AC above 2 000 m max. 132 V AC above 2 000 m max. 132 V AC
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
■ Technical specifications
Article number 6AG1214-1HG40-4XB0 6AG1214-1HG40-5XB0 6AG1214-1HG40-2XB0
Based on 6ES7214-1HG40-0XB0 6ES7214-1HG40-0XB0 6ES7214-1HG40-0XB0
SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C SIPLUS S7-1200 CPU 1214C
DC/DC/RLY DC/DC/RLY DC/DC/RLY
■ Overview
• The compact high-performance CPU
• With 24 integrated I/Os
• Expandable with:
- 1 signal board (SB) or communication board (CB);
not possible with: 6AG1215-1AG40-2XB0,
6AG1215-1BG40-2XB0, 6AG1215-1HG40-2XB0 3
- 8 signal modules (SM)
- Max. 3 communications modules (CM)
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
3
with 6AG1215-1....-2XB0)
Integrated program and data
memory 125 KB, load memory 2 inputs, 24 V DC,
4 MB; IEC type 1 sinking input;
power supply 24 V DC; 2 transistor outputs 24 V DC,
Boolean execution times 0.5 A, 5 W;
0.085 μs per operation; can be used as HSC at
14 digital inputs, up to 30 kHz
10 digital outputs (relay), • Suitable for areas with extreme 6AG1223-0BD30-4XB0
2 analog inputs, exposure to media (conformal
2 analog outputs; coating)
expandable by up to • Ambient temperature 6AG1223-0BD30-5XB0
3 communications modules, -25 ... +55 °C
8 signal modules and 1 signal
board/communication board; 2 inputs, 5 V DC, 200 kHz 6AG1223-3AD30-5XB0
digital inputs usable as HSC with 2 outputs 5 V DC, 0.1 A, 200 kHz
100 kHz
2 inputs, 24 V DC, 200 kHz 6AG1223-3BD30-5XB0
• For areas with extreme exposure 6AG1215-1HG40-4XB0
2 outputs 24 V DC, 0.1 A, 200 kHz
to media (conformal coating);
ambient temperature SIPLUS SB 1232 analog output
-20 ... +60 °C signal board
• For areas with extreme exposure 6AG1215-1HG40-5XB0
(Extended temperature range and
to media (conformal coating);
exposure to media; cannot be used
ambient temperature
with 6AG1215-1....-2XB0)
-40 ... +60 °C
• For areas with extreme exposure 6AG1215-1HG40-2XB0 Ambient temperature range
to media (conformal coating); -25 ... +55 °C
ambient temperature
-40 ... +70 °C 1 analog output, ±10 V with 12 bits 6AG1232-4HA30-5XB0
or 0 ... 20 mA with 11 bits
Accessories
Ambient temperature range
SIPLUS SB 1221 digital input 0 ... +55 °C
signal board
1 analog output, ±10 V with 12 bits 6AG1232-4HA30-4XB0
(Extended temperature range and or 0 ... 20 mA with 11 bits
exposure to media; cannot be used
with 6AG1215-1....-2XB0) SIPLUS CB 1241 RS 485
communication board
4 inputs, 5 V DC, 200 kHz, 6AG1221-3AD30-5XB0
sourcing input (Extended temperature range and
exposure to media; cannot be used
4 inputs, 24 V DC, 200 kHz, 6AG1221-3BD30-5XB0 with 6AG1215-1....-2XB0)
sourcing input
for point-to-point connection, 6AG1241-1CH30-5XB1
SIPLUS SB 1222 digital output with 1 RS 485 interface
signal board
Additional accessories See SIMATIC S7-1200
(Extended temperature range and CPU 1215C, page 3/17
exposure to media; cannot be used
with 6AG1215-1....-2XB0)
4 outputs, 5 V DC, 0.1 A, 200 kHz 6AG1222-1AD30-5XB0
4 outputs, 24 V DC, 0.1 A, 200 kHz 6AG1222-1BD30-5XB0
■ Technical specifications
Article number 6AG1215-1AG40-4XB0 6AG1215-1AG40-5XB0 6AG1215-1AG40-2XB0
Based on 6ES7215-1AG40-0XB0 6ES7215-1AG40-0XB0 6ES7215-1AG40-0XB0
SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C
DC/DC/DC DC/DC/DC DC/DC/DC
Ambient conditions
Ambient temperature during
3
operation
• min. -20 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ 0 °C start-up @ -25 °C start-up @ -25 °C
• max. 60 °C; Number of simultaneously 60 °C; = Tmax; Tmax > +55 °C number 70 °C; = Tmax; Tmax > +55 °C number
activated inputs or outputs 7 or 5 (no of simultaneously switched-on digital of simultaneously switched-on digital
adjacent points) at 60 °C horizontal or inputs 7, digital outputs 5, analog inputs 7, digital outputs 5, analog
50 °C vertical, 14 or 10 at 55 °C inputs 2, analog outputs 2 (no adjacent inputs 2, analog outputs 2 (no adjacent
horizontal or 45 °C vertical points) with horizontal mounting points) with horizontal mounting
position position; Tmax > +60 °C number of
simultaneously switched-on digital
inputs 7, digital outputs 5, analog
inputs 1, analog outputs 1 (no adjacent
points) with horizontal mounting
position
• At cold restart, min. 0 °C -25 °C -25 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1215-1AG40-4XB0 6AG1215-1AG40-5XB0 6AG1215-1AG40-2XB0
Based on 6ES7215-1AG40-0XB0 6ES7215-1AG40-0XB0 6ES7215-1AG40-0XB0
SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C
DC/DC/DC DC/DC/DC DC/DC/DC
3 Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1215-1BG40-4XB0 6AG1215-1BG40-5XB0 6AG1215-1BG40-2XB0
Based on 6ES7215-1BG40-0XB0 6ES7215-1BG40-0XB0 6ES7215-1BG40-0XB0
SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C
AC/DC/RLY AC/DC/RLY AC/DC/RLY
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
3
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1215-1HG40-4XB0 6AG1215-1HG40-5XB0 6AG1215-1HG40-2XB0
Based on 6ES7215-1HG40-0XB0 6ES7215-1HG40-0XB0 6ES7215-1HG40-0XB0
SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C SIPLUS S7-1200 CPU 1215C
DC/DC/RLY DC/DC/RLY DC/DC/RLY
3
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Overview
• Standard controller with integrated safety functions:
- Standardized and convenient diagnostic functions for
standard and safety
- Uniform symbols, data consistency, ...
• Modular system with scalable range of CPUs and expandable
I/O quantity structure: 3
- One engineering for standard and fail-safe automation
- Use of the standard I/O modules together with the fail-safe
I/O modules in the central system
- Integrated standard PROFINET functionalities for
PROFINET controllers and PROFINET iDevice services
- Connection of distributed standard I/O via field bus such as
PROFINET or PROFIBUS
- F-library certified by the German Technical Inspectorate
(TÜV) for all common safety functions
- Free programming of the safety logic using FBD and LAD
- Standard-compliant printout of the F-program
The fail-safe SIMATIC S7-1200 Controllers are based on the • One integrated engineering for both standard and safety from
S7-1200 standard CPUs and offer additional safety-related S7-1200 to S7-300/400/1500 and WinAC RTX F:
functions. - STEP 7 Safety Basic for easy engineering of the CPU 1200 FC
They can be used for safety-oriented tasks according - STEP 7 Safety Advanced for the entire fail-safe SIMATIC S7
to IEC 61508 up to SIL 3 and ISO 13849-1 up to PL e. portfolio
Safety-related programs are created in the TIA Portal. • Integrated system diagnosis of the CPUs, for standard and
The STEP 7 Safety engineering tool offers commands, safety:
operations and blocks for safety-related programs in the - Consistent plain text display of system diagnostic
LAD and FBD languages. To this end, there is a library with information in the TIA Portal, HMI and web server
pre-configured, TÜV-approved blocks for safety-related - Messages are updated even if the CPU is in STOP state
functions. - System diagnostics integrated in the CPU firmware.
Configuration by user not required
- The diagnostics is automatically updated on configuration
changes.
• 2 fail-safe compact controllers with graded performances
in the versions DC/DC/DC and DC/DC/relay
3
100 KB, load memory 2 MB; 150 KB, load memory 4 MB;
supply voltage 24 V DC; supply voltage 24 V DC;
Boolean execution times Boolean execution times
0.085 μs per operation; 0.085 μs per operation;
8 digital inputs, 14 digital inputs,
6 digital outputs, 10 digital outputs,
2 analog inputs; expandable by 2 analog inputs;
up to 3 communications modules, 2 analog outputs; expandable by
2 signal modules, and 1 signal up to 3 communications modules,
board/communication board; 8 signal modules, and 1 signal
digital inputs can be used as HSC board/communication board;
at 100 kHz, digital inputs can be used as HSC
24 V DC digital outputs can be at 100 kHz,
used as pulse outputs (PTO) or 24 V DC digital outputs can be
pulse-width modulated outputs used as pulse outputs (PTO) or
(PWM) at 100 kHz pulse-width modulated outputs
(PWM) at 100 kHz
Fail-safe compact CPU, 6ES7212-1HF40-0XB0
DC/DC/relay; Fail-safe compact CPU, 6ES7215-1HF40-0XB0
integrated program/data memory DC/DC/relay;
125 KB, load memory 2 MB; integrated program/data memory
supply voltage 24 V DC; 150 KB, load memory 4 MB;
Boolean execution times supply voltage 24 V DC;
0.085 μs per operation; Boolean execution times
8 digital inputs, 0.085 μs per operation;
6 digital outputs (relays), 14 digital inputs,
2 analog inputs; 10 digital outputs (relays),
expandable by up to 2 analog inputs;
3 communications modules, 2 analog outputs;
2 signal modules, and 1 signal expandable by up to
board/communication board; 3 communications modules,
digital inputs can be used as HSC 8 signal modules, and 1 signal
at 100 kHz board/communication board;
Digital inputs can be used as HSC
CPU 1214FC at 100 kHz
Fail-safe compact CPU, 6ES7214-1AF40-0XB0 Accessories
DC/DC/DC;
integrated program/data memory SIMATIC S7-1200 Fail-Safe Starter
125 KB, load memory 4 MB; Kit
supply voltage 24 V DC;
Boolean execution times With CPU 1212 FC DC/DC/relay; 6ES7212-1HF41-4YB1
0.085 μs per operation; also includes:
14 digital inputs, F-digital input SM 1226 16 x 24 V
10 digital outputs, DC, F-digital output SM 1226 4 x 24
2 analog inputs; V DC, input simulator, STEP 7 Basic
expandable by up to and STEP 7 Safety Basic V16,
3 communications modules, SIMATIC OPC UA S7-1200 Basic,
8 signal modules, and 1 signal info material; in Systainer
board/communication board; With CPU 1214 FC DC/DC/relay; 6ES7212-1HF42-4YB1
digital inputs can be used as HSC also includes: F-digital input
at 100 kHz, SM 1226 16 x 24 V DC,
24 V DC digital outputs can be F-digital output SM 1226 4 x 24 V DC,
used as pulse outputs (PTO) or input simulator, STEP 7 Safety Basic,
pulse-width modulated outputs SIMATIC OPC UA S7-1200 Basic,
(PWM) at 100 kHz info material; in Systainer
Fail-safe compact CPU, 6ES7214-1HF40-0XB0 Simulator (optional) 6ES7274-1XH30-0XA0
DC/DC/relay;
integrated program/data memory 14 incoming circuit breakers
125 KB, load memory 4 MB; supply
SIMATIC Memory Card (optional)
voltage 24 V DC;
Boolean execution times 4 MB 6ES7954-8LC03-0AA0
0.085 μs per operation;
14 digital inputs, 12 MB 6ES7954-8LE03-0AA0
10 digital outputs (relays), 24 MB 6ES7954-8LF03-0AA0
2 analog inputs;
expandable by up to 256 MB 6ES7954-8LL03-0AA0
3 communications modules,
8 signal modules, and 2 GB 6ES7954-8LP03-0AA0
1 signal board/communication board; 32 GB 6ES7954-8LT03-0AA0
digital inputs can be used as HSC
at 100 kHz
3
programs for SIMATIC S7-1200 FC,
Terminal block (spare part) S7-1500F, S7-1500F Software
For CPU 1214FC, DC/DC/DC Controller, S7-300F, S7-400F,
• For DI, with 20 screws, tin-coated; 6ES7292-1AV30-0XA0 WinAC RTX F, ET 200SP F
4 units Controller and the fail-safe
ET 200SP, ET 200MP, ET 200S,
• For DO, with 12 screws, tin-coated; 6ES7292-1AM30-0XA0 ET 200M, ET 200iSP, ET 200pro and
4 units ET 200eco I/O
• For AI, with 3 screws, gold-plated; 6ES7292-1BC30-0XA0 Requirement:
4 units STEP 7 Professional V17
For CPU 1214FC, DC/DC/relay Note:
• For DI, with 20 screws, tin-coated; 6ES7292-1AV30-0XA0 As of TIA Portal V16,
4 units the SIMATIC STEP 7 Safety software
• For DO, with 12 screws, tin-coated, 6ES7292-1AM40-0XA0 is an integral component of the
coded; 4 units SIMATIC STEP 7 product setup.
• For AI, with 3 screws, gold-plated; 6ES7292-1BC30-0XA0 The functionality of SIMATIC STEP 7
4 units Safety is activated by means of the
license key supplied in each case.
For CPU 1215FC, DC/DC/DC
Floating license for 1 user; 6ES7833-1FA17-0YA5
• For DI, with 20 screws, tin-coated; 6ES7292-1AV30-0XA0 license key on USB flash drive
4 units
• For DO, with 12 screws, tin-coated; 6ES7292-1AM30-0XA0 Floating license for 1 user; 6ES7833-1FA17-0YH5
4 units license key for download1);
• For AI, with 6 screws, gold-plated; 6ES7292-1BF30-0XB0 Email address required for delivery
4 units STEP 7 Safety Basic V17
For CPU 1215FC, DC/DC/relay Task:
• For DI, with 20 screws, tin-coated; 6ES7292-1AV30-0XA0 Engineering tool for configuring
4 units fail-safe user programs for
• For DO, with 12 screws, tin-coated, 6ES7292-1AM40-0XA0 SIMATIC S7-1200 FC
coded; 4 units Requirement:
• For AI, with 6 screws, gold-plated; 6ES7292-1BF30-0XB0 STEP 7 Basic V17 and higher
4 units Note:
Front flap set (spare part) As of TIA Portal V16,
the SIMATIC STEP 7 Safety software
For CPU 1214FC 6ES7291-1AB30-0XA0 is an integral component of the
SIMATIC STEP 7 product setup.
For CPU 1215FC 6ES7291-1AC30-0XA0
The functionality of SIMATIC STEP 7
RJ45 cable grip Safety is activated by means of the
license key supplied in each case.
4 units per pack
Floating license for 1 user; 6ES7833-1FB17-0YA5
Single port 6ES7290-3AA30-0XA0 license key on USB flash drive
Dual port 6ES7290-3AB30-0XA0 Floating license for 1 user; 6ES7833-1FB17-0YH5
license key for download1);
email address required for delivery
1) For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7212-1AF40- 6ES7212-1HF40- 6ES7214-1AF40- 6ES7214-1HF40- 6ES7215-1AF40- 6ES7215-1HF40-
0XB0 0XB0 0XB0 0XB0 0XB0 0XB0
CPU 1212FC, CPU 1212FC, CPU 1214 FC, CPU 1214 FC, CPU 1215 FC, CPU 1215 FC,
DC/DC/DC, DC/DC/Relay, DC/DC/DC, DC/DC/Relay, DC/DC/DC,14DI/ DC/DC/RLY,14DI/
8DI/6DO/2AI 8DI/6DO/2AI 14DI/10DO/2AI 14DI/10DO/2AI 10DO/2AI/2AO 10DO/2AI/2AO
General information
Product type designation CPU 1212FC CPU 1212FC CPU 1214FC CPU 1214FC CPU 1215FC CPU 1215FC
DC/DC/DC DC/DC/relay DC/DC/DC DC/DC/Relay DC/DC/DC DC/DC/relay
Engineering with
• Programming package STEP 7 V17 or STEP 7 V17 or STEP 7 V17 or STEP 7 V17 or STEP 7 V17 or STEP 7 V17 or
higher higher higher higher higher higher
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7212-1AF40- 6ES7212-1HF40- 6ES7214-1AF40- 6ES7214-1HF40- 6ES7215-1AF40- 6ES7215-1HF40-
0XB0 0XB0 0XB0 0XB0 0XB0 0XB0
CPU 1212FC, CPU 1212FC, CPU 1214 FC, CPU 1214 FC, CPU 1215 FC, CPU 1215 FC,
DC/DC/DC, DC/DC/Relay, DC/DC/DC, DC/DC/Relay, DC/DC/DC,14DI/ DC/DC/RLY,14DI/
8DI/6DO/2AI 8DI/6DO/2AI 14DI/10DO/2AI 14DI/10DO/2AI 10DO/2AI/2AO 10DO/2AI/2AO
3 Encoder supply
24 V encoder supply
• 24 V L+ minus 4 V DC L+ minus 4 V DC L+ minus 4 V DC L+ minus 4 V DC L+ minus 4 V DC L+ minus 4 V DC
min. min. min. min. min. min.
Memory
Work memory
• integrated 100 kbyte 100 kbyte 125 kbyte 125 kbyte 150 kbyte 150 kbyte
Load memory
• integrated 2 Mbyte 2 Mbyte 4 Mbyte 4 Mbyte 4 Mbyte 4 Mbyte
• Plug-in (SIMATIC Memory Card), with SIMATIC with SIMATIC with SIMATIC with SIMATIC with SIMATIC with SIMATIC
max. memory card memory card memory card memory card memory card memory card
Backup
• without battery Yes Yes Yes Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / 0.08 µs; / 0.08 µs; / 0.08 µs; / 0.08 µs; / 0.08 µs; /
instruction instruction instruction instruction instruction instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
Data areas and their retentivity
Flag
• Size, max. 4 kbyte; Size of bit 4 kbyte; Size of bit 8 kbyte; Size of bit 8 kbyte; Size of bit 8 kbyte; Size of bit 8 kbyte; Size of bit
memory address memory address memory address memory address memory address memory address
area area area area area area
Process image
• Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte 1 kbyte 1 kbyte 1 kbyte
• Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte 1 kbyte 1 kbyte 1 kbyte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes Yes Yes Yes
Digital inputs
Number of digital inputs 8; Integrated 8; Integrated 14; Integrated 14; Integrated 14; Integrated 14; Integrated
• of which inputs usable for 4; HSC (High 4; HSC (High 6; HSC (High 6; HSC (High 6; HSC (High 6; HSC (High
technological functions Speed Counting) Speed Counting) Speed Counting) Speed Counting) Speed Counting) Speed Counting)
Digital outputs
Number of digital outputs 6 6; Relays 10 10; Relays 10 10; Relays
• of which high-speed outputs 4; 100 kHz Pulse 4; 100 kHz Pulse 4; 100 kHz Pulse
Train Output Train Output Train Output
Analog inputs
Number of analog inputs 2 2 2 2 2 2
Input ranges
• Voltage Yes Yes Yes Yes Yes Yes
Analog outputs
Number of analog outputs 0 0 0 2 2
Output ranges, current
• 0 to 20 mA Yes Yes
1. Interface
Protocols
• PROFINET IO Controller Yes Yes Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes Yes Yes
• Open IE communication Yes; Optionally Yes; Optionally Yes; Optionally Yes; Optionally Yes; Optionally Yes; Optionally
also encrypted also encrypted also encrypted also encrypted also encrypted also encrypted
• Web server Yes Yes Yes Yes Yes Yes
• Media redundancy No No No No Yes; as MRP client Yes
■ Technical specifications
Article number 6ES7212-1AF40- 6ES7212-1HF40- 6ES7214-1AF40- 6ES7214-1HF40- 6ES7215-1AF40- 6ES7215-1HF40-
0XB0 0XB0 0XB0 0XB0 0XB0 0XB0
CPU 1212FC, CPU 1212FC, CPU 1214 FC, CPU 1214 FC, CPU 1215 FC, CPU 1215 FC,
DC/DC/DC, DC/DC/Relay, DC/DC/DC, DC/DC/Relay, DC/DC/DC,14DI/ DC/DC/RLY,14DI/
8DI/6DO/2AI 8DI/6DO/2AI 14DI/10DO/2AI 14DI/10DO/2AI 10DO/2AI/2AO 10DO/2AI/2AO
Protocols 3
Open IE communication
• TCP/IP Yes Yes Yes Yes Yes Yes
• ISO-on-TCP (RFC1006) Yes Yes Yes Yes Yes Yes
• UDP Yes Yes Yes Yes Yes Yes
Web server
• supported Yes Yes Yes Yes Yes Yes
OPC UA
• OPC UA Server Yes; data access Yes; data access Yes; data access Yes; data access Yes; data access Yes; data access
(read, write, (read, write, (read, write, (read, write, (read, write, (read, write,
subscribe), method subscribe), method subscribe), method subscribe), method subscribe), method subscribe), method
call, runtime license call, runtime license call, runtime license call, runtime license call, runtime license call, runtime license
required required required required required required
Communication functions
S7 communication
• supported Yes Yes Yes Yes Yes Yes
Integrated Functions
Frequency measurement Yes Yes Yes Yes Yes Yes
controlled positioning Yes Yes Yes Yes Yes Yes
Number of position-controlled 8 8 8 8 8 8
positioning axes, max.
Number of positioning axes via Up to 4 with SB Up to 4 with SB 4; With integrated Up to 4 with SB 4; With integrated Up to 4 with SB
pulse-direction interface 1222 1222 outputs 1222 outputs 1222
PID controller Yes Yes Yes Yes Yes Yes
Number of alarm inputs 4 4 4 4 4 4
Number of pulse outputs 4 4 4
Limit frequency (pulse) 100 kHz 100 kHz 100 kHz
Ambient conditions
Ambient temperature during
operation
• min. 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C
• max. 55 °C; Number of 55 °C; Number of 55 °C; Number of 55 °C; Number of 55 °C; Number of 55 °C; Number of
simultaneously simultaneously simultaneously simultaneously simultaneously simultaneously
activated inputs or activated inputs or activated inputs or activated inputs or activated inputs or activated inputs or
outputs 4 or 3 outputs 4 or 3 outputs 4 or 3 outputs 4 or 3 outputs 4 or 3 outputs 4 or 3
(no adjacent (no adjacent (no adjacent (no adjacent (no adjacent (no adjacent
points) at 60 °C points) at 60 °C points) at 60 °C points) at 60 °C points) at 60 °C points) at 60 °C
horizontal or 50 °C horizontal or 50 °C horizontal or 50 °C horizontal or 50 °C horizontal or 50 °C horizontal or 50 °C
vertical, 8 or 6 at vertical, 8 or 6 at vertical, 8 or 6 at vertical, 8 or 6 at vertical, 8 or 6 at vertical, 8 or 6 at
55 °C horizontal or 55 °C horizontal or 55 °C horizontal or 55 °C horizontal or 55 °C horizontal or 55 °C horizontal or
45 °C vertical 45 °C vertical 45 °C vertical 45 °C vertical 45 °C vertical 45 °C vertical
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; S02: < 0.5 ppm; S02: < 0.5 ppm; S02: < 0.5 ppm; S02: < 0.5 ppm; S02: < 0.5 ppm;
condensation H2S: < 0.1 ppm; H2S: < 0.1 ppm; H2S: < 0.1 ppm; H2S: < 0.1 ppm; H2S: < 0.1 ppm; H2S: < 0.1 ppm;
RH < 60% RH < 60% RH < 60% RH < 60% RH < 60% RH < 60%
condensation-free condensation-free condensation-free condensation-free condensation-free condensation-free
Configuration
Programming
Programming language
- LAD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- FBD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- SCL Yes Yes Yes Yes Yes Yes
Dimensions
Width 90 mm 90 mm 110 mm 110 mm 130 mm 130 mm
Height 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm
Weights
Weight, approx. 370 g 385 g 415 g 435 g 500 g 585 g
■ Overview
Characteristics SIPLUS SIPLUS
CPU 1214 FC CPU 1215 FC
Variants DC/DC/DC, DC/DC/DC
DC/DC/relay
■ Technical specifications
Article number 6AG1214-1AF40-5XB0 6AG1214-1HF40-5XB0 6AG1215-1AF40-5XB0
Based on 6ES7214-1AF40-0XB0 6ES7214-1HF40-0XB0 6ES7215-1AF40-0XB0
SIPLUS S7-1200 CPU 1214FC SIPLUS S7-1200 CPU 1214FC SIPLUS S7-1200 CPU 1215FC
DC/DC/DC DC/DC/RLY DC/DC/DC
3 Ambient conditions
Ambient temperature during
operation
• min. -25 °C; = Tmin -25 °C; = Tmin -25 °C; = Tmin
• max. 55 °C; = Tmax 55 °C; = Tmax 55 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; incl. condensation / frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under permitted (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes Yes Yes
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas trichlorethylene; harmful gas trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6ES7221-1BF32-0XB0 6ES7221-1BH32-0XB0
Digital Input SM 1221, 8DI, 24V DC Digital Input SM 1221, 16DI, 24V DC
General information
Product type designation SM 1221, DI 8x24 V DC SM 1221, DI 16x24 V DC
Supply voltage
Rated value (DC) 24 V 24 V
Input current
from backplane bus 5 V DC, max. 105 mA 130 mA
Digital inputs
• from load voltage L+ (without load), 4 mA; per channel 4 mA; per channel
max.
Output voltage
Power supply to the transmitters
• present Yes Yes
Digital inputs
Number of digital inputs 8 16
• in groups of 2 4
Input characteristic curve in Yes Yes
accordance with IEC 61131, type 1
Number of simultaneously
controllable inputs
all mounting positions
- up to 40 °C, max. 8 16
horizontal installation
- up to 40 °C, max. 8 16
- up to 50 °C, max. 8 16
vertical installation
- up to 40 °C, max. 8 16
Input voltage
• Rated value (DC) 24 V 24 V
• for signal "0" 5 V DC at 1 mA 5 V DC at 1 mA
• for signal "1" 15 V DC at 2.5 mA 15 V DC at 2.5 mA
■ Technical specifications
Article number 6ES7221-1BF32-0XB0 6ES7221-1BH32-0XB0
Digital Input SM 1221, 8DI, 24V DC Digital Input SM 1221, 16DI, 24V DC
Input current
• for signal "0", max. 1 mA 1 mA
3 (permissible quiescent current)
• for signal "1", min. 2.5 mA 2.5 mA
• for signal "1", typ. 4 mA 4 mA
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and
12.8 ms, selectable in groups of four 12.8 ms, selectable in groups of four
for interrupt inputs
- parameterizable Yes Yes
Interrupts/diagnostics/
status information
Alarms
• Diagnostic alarm Yes Yes
Diagnostics indication LED
• for status of the inputs Yes Yes
Potential separation
Potential separation digital inputs
• between the channels, in groups of 2 4
Standards, approvals, certificates
CE mark Yes Yes
CSA approval Yes Yes
UL approval Yes Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Connection method
required front connector Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes
Dimensions
Width 45 mm 45 mm
Height 100 mm 100 mm
Depth 75 mm 75 mm
Weights
Weight, approx. 170 g 210 g
■ Technical specifications
Article number 6ES7221-3AD30-0XB0 6ES7221-3BD30-0XB0
Signal Board SB 1221, 4 DI 5VDC 200KHz Signal Board SB 1221, 4 DI 24VDC 200KHz
General information
Product type designation SB 1221, DI 4x5 V DC 200 kHz SB 1221, DI 4x24 V DC 200 kHz
Input current
from backplane bus 5 V DC, typ. 40 mA 40 mA
Digital inputs
Number of digital inputs 4; Current-sourcing 4; Current-sourcing
• in groups of 4 4
Input voltage
• Type of input voltage DC DC
• Rated value (DC) 5V 24 V
• for signal "0" (L+ minus 1.0 V DC) ... L+ (2.2 ... 0 mA) (L+ minus 5.0 V DC) ... L+ (1.4 ... 0 mA)
• for signal "1" 0 V ... (L+ minus 2.0 V DC (20 ... 5.1 mA)) 0 V ... (L+ minus 10 V DC (10 ... 2.9 mA))
Input current
• for signal "0", max. 2.2 mA 1.4 mA
(permissible quiescent current)
• for signal "1", min. 5.1 mA 2.9 mA
• for signal "1", typ. 7 mA
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs;
0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 /
20.0 ms 20.0 ms
for interrupt inputs
- parameterizable Yes Yes
for technological functions
- parameterizable Yes Yes
Diagnostics indication LED
• for status of the inputs Yes Yes
■ Technical specifications
Article number 6ES7221-3AD30-0XB0 6ES7221-3BD30-0XB0
Signal Board SB 1221, 4 DI 5VDC 200KHz Signal Board SB 1221, 4 DI 24VDC 200KHz
Standards, approvals, certificates
CE mark Yes Yes
3 CSA approval
UL approval
Yes
Yes
Yes
Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes
Dimensions
Width 38 mm 38 mm
Height 62 mm 62 mm
Depth 21 mm 21 mm
Weights
Weight, approx. 35 g 35 g
• For flexible adaptation of the controller to the relevant task For connecting digital/analog signal
modules; length 2 m
• For subsequent expansion of the system with additional outputs
Terminal block (spare part)
For 6ES7222-1BF32-0XB0,
6ES7222-1BH32-0XB0
• 7-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AG30-0XA0
- Push-in system 6ES7292-2AG30-0XA0
For 6ES7222-1HF32-0XB0
• 7-pin, tin-coated, left coded;
4 units
- Screw-type system 6ES7292-1AG40-0XA1
- Push-in system 6ES7292-2AG40-0XA1
For 6ES7222-1HH32-0XB0
• 7-pin, tin-coated, right coded;
4 units
- Screw-type system 6ES7292-1AG40-0XA0
- Push-in system 6ES7292-2AG40-0XA0
For 6ES7222-1XF32-0XB0
• 11-pin, tin-coated, right coded;
4 units
- Screw-type system 6ES7292-1AL40-0XA0
- Push-in system 6ES7292-2AL40-0XA0
Front flap set (spare part)
For modules with a width of 45 mm 6ES7291-1BA30-0XA0
For modules with a width of 70 mm 6ES7291-1BB30-0XA0
■ Technical specifications
Article number 6ES7222-1BF32- 6ES7222-1BH32- 6ES7222-1BH32- 6ES7222-1HF32- 6ES7222-1HH32- 6ES7222-1XF32-
0XB0 0XB0 1XB0 0XB0 0XB0 0XB0
Digital Output Digital Output Digital Output Digital Output Digital Output Digital Output
SM1222, 8 DO, SM1222, 16 DO, SM1222, 16DO, SM 1222, 8 DO, SM1222, 16 DO, SM 1222, 8 DO,
24V DC 24V DC 24V DC sink Relay Relay Changeover
3 General information
Product type designation SM 1222, DQ SM 1222, DQ SM 1222, DO SM 1222, DQ SM 1222, DQ SM 1222, DQ
8x24 V DC/0.5 A 16x24 V DC/0.5 A 16x 24 V DC/0.5 A 8x relay/2 A 16x relay/2 A 8x relay/2 A
Sink
Input current
from backplane bus 5 V DC, max. 120 mA 140 mA 140 mA 120 mA 135 mA 140 mA
Digital outputs
• from load voltage L+, max. 11 mA/relay coil 11 mA/relay coil 16.7 mA/relay coil
Digital outputs
Number of digital outputs 8 16 16 8 16 8
• in groups of 1 1 1 2 1 1
Current-sinking Yes
Short-circuit protection No; to be provided No; to be provided No; to be provided No; to be provided No; to be provided No; to be provided
externally externally externally externally externally externally
Limitation of inductive shutdown typ. (L+) -48 V typ. (L+) -48 V Typ 45 V
voltage to
Switching capacity of the outputs
• with resistive load, max. 0.5 A 0.5 A 0.5 A 2A 2A 2A
• on lamp load, max. 5W 5W 5W 30 W with DC, 30 W with DC, 30 W with DC,
200 W with AC 200 W with AC 200 W with AC
Output voltage
• Rated value (DC) 24 V 24 V 24 V 5 V DC to 5 V DC to 5 V DC to
30 V DC 30 V DC 30 V DC
• Rated value (AC) 5 V AC to 5 V AC to 5 V AC to
250 V AC 250 V AC 250 V AC
• for signal "0", max. 0.1 V; 0.1 V; L+ minus
with 10 kOhm load with 10 kOhm load 0.75 V DC
with 10k Load
• for signal "1", min. 20 V DC 20 V DC
Output current
• for signal "1" rated value 0.5 A 0.5 A 0.5 A 2A 2A 2A
• for signal "0" residual current, max. 10 µA 10 µA 75 µA
Output delay with resistive load
• "0" to "1", max. 50 µs 50 µs 20 µs 10 ms 10 ms 10 ms
• "1" to "0", max. 200 µs 200 µs 350 µs 10 ms 10 ms 10 ms
Total current of the outputs
(per group)
horizontal installation
- up to 50 °C, max. 4 A; Current per 8 A; Current per 8 A; Current per 10 A; Current per 10 A; Current per 2 A; Current per
mass mass mass mass mass mass
Relay outputs
• Number of relay outputs 8 16 8
• Rated supply voltage of relay 24 V 24 V 24 V
coil L+ (DC)
• Number of operating cycles, max. mechanically mechanically mechanically
10 million, 10 million, 10 million,
at rated load at rated load at rated load
voltage 100 000 voltage 100 000 voltage 100 000
Switching capacity of contacts
- with inductive load, max. 0.5 A 0.5 A 0.5 A 2A 2A 2A
- on lamp load, max. 5W 5W 5W 30 W with DC, 30 W with DC, 30 W with DC,
200 W with AC 200 W with AC 200 W with AC
- with resistive load, max. 0.5 A 0.5 A 0.5 A 2A 2A 2A
■ Technical specifications
Article number 6ES7222-1BF32- 6ES7222-1BH32- 6ES7222-1BH32- 6ES7222-1HF32- 6ES7222-1HH32- 6ES7222-1XF32-
0XB0 0XB0 1XB0 0XB0 0XB0 0XB0
Digital Output Digital Output Digital Output Digital Output Digital Output Digital Output
SM1222, 8 DO, SM1222, 16 DO, SM1222, 16DO, SM 1222, 8 DO, SM1222, 16 DO, SM 1222, 8 DO,
24V DC 24V DC 24V DC sink Relay Relay Changeover
Interrupts/diagnostics/
status information
3
Alarms
• Diagnostic alarm Yes Yes Yes Yes Yes Yes
Diagnostics indication LED
• for status of the outputs Yes Yes Yes Yes Yes Yes
Potential separation
Potential separation digital outputs
• between the channels Relays Relays Relays
• between the channels, in groups of 1 1 1 2 4 1
• between the channels and 500 V AC 500 V AC 500 V AC 1 500 V AC for 1 500 V AC for 1 500 V AC for
backplane bus 1 minute 1 minute 1 minute
Standards, approvals, certificates
CE mark Yes Yes Yes Yes Yes Yes
CSA approval Yes Yes Yes Yes Yes Yes
UL approval Yes Yes Yes Yes Yes Yes
cULus Yes Yes Yes Yes Yes Yes
FM approval Yes Yes Yes Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes Yes Yes Yes
KC approval Yes Yes Yes Yes Yes Yes
Marine approval Yes Yes Yes Yes Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C 60 °C 60 °C; Number of 60 °C; Number of
simultaneously simultaneously
activated outputs: activated outputs:
8 (no adjacent 4 (no adjacent
points) at 60 °C points) at 60 °C
horizontal or 50 °C horizontal or 50 °C
vertical, 16 at vertical, 8 at 55 °C
55 °C horizontal or horizontal or 45 °C
45 °C vertical vertical
Connection method
required front connector Yes Yes Yes Yes Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes Yes Yes Yes Yes
Dimensions
Width 45 mm 45 mm 45 mm 45 mm 45 mm 70 mm
Height 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm
Weights
Weight, approx. 180 g 220 g 220 g 190 g 260 g 310 g
■ Technical specifications
Article number 6ES7222-1AD30-0XB0 6ES7222-1BD30-0XB0
Signal Board SB1222, 4 DQ 5VDC 200KHz Signal Board SB1222, 4 DQ 24VDC 200KHz
General information
Product type designation SB 1222, DQ 4x5 V DC 200 kHz SB 1222, DQ 4x24 V DC 200 kHz
Input current
from backplane bus 5 V DC, typ. 35 mA 35 mA
3
Digital outputs
Number of digital outputs 4; MOSFET, solid-state (current-sinking/current-sourcing) 4; MOSFET, solid-state (current-sinking/current-sourcing)
• in groups of 4 4
Short-circuit protection No No
Switching capacity of the outputs
• with resistive load, max. 0.1 A 0.1 A
Load resistance range
• upper limit 7Ω 11 Ω
Output voltage
• Rated value (DC) 5V 24 V
• for signal "0", max. 0.2 V 1 V; with 10 kOhm load
• for signal "1", min. L+ minus 0.7 V DC L+ (-1.5 V)
• for signal "1", max. 6V
Output current
• for signal "1" permissible range, 0.1 A 0.1 A
max.
Diagnostics indication LED
• for status of the outputs Yes Yes
Standards, approvals, certificates
CE mark Yes Yes
CSA approval Yes Yes
UL approval Yes Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes
Dimensions
Width 38 mm 38 mm
Height 62 mm 62 mm
Depth 21 mm 21 mm
Weights
Weight, approx. 35 g 35 g
3
8 x 24 V DC transistor outputs,
0.5 A, 5 W
16 inputs, 24 V DC, 6ES7223-1BL32-0XB0
IEC type 1 sinking input;
16 x 24 V DC transistor outputs,
0.5 A, 5 W
16 inputs, 24 V DC, 6ES7223-1BL32-1XB0
IEC type 1 sinking input;
16 x 24 V DC transistor outputs,
0.5 A, 5 W, switching to P potential
8 inputs, 24 V DC, 6ES7223-1PH32-0XB0
IEC type 1 sinking input;
8 relay outputs,
5 ... 30 V DC/5 ... 250 V AC, 2 A,
30 W DC/200 W AC
16 inputs, 24 V DC, 6ES7223-1PL32-0XB0
IEC type 1 sinking input;
• Digital inputs and outputs as supplement to the integral I/O 16 relay outputs,
of the CPUs 5 ... 30 V DC/5 ... 250 V AC, 2 A,
• For flexible adaptation of the controller to the relevant task 30 W DC/200 W AC
• For subsequent expansion of the system with additional inputs 8 inputs, 120/230 V AC; 6ES7223-1QH32-0XB0
8 relay outputs,
and outputs 5 ... 30 V DC/5 ... 250 V AC, 2 A,
30 W DC/200 W AC
Extension cable for two-tier 6ES7290-6AA30-0XA0
configuration
For connecting digital/analog signal
modules; length 2 m
Terminal block (spare part)
For 6ES7223-1BH32-0XB0
• 7-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AG30-0XA0
- Push-in system 6ES7292-2AG30-0XA0
For 6ES7223-1BL32-0XB0
• 11-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AL30-0XA0
- Push-in system 6ES7292-2AL30-0XA0
For 6ES7223-1PH32-0XB0
• 7-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AG30-0XA0
- Push-in system 6ES7292-2AG30-0XA0
• 7-pin, tin-coated, right coded;
4 units
- Screw-type system 6ES7292-1AG40-0XA0
- Push-in system 6ES7292-2AG40-0XA0
For 6ES7223-1PL32-0XB0
• 11-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AL30-0XA0
- Push-in system 6ES7292-2AL30-0XA0
• 11-pin, tin-coated, coded;
4 units
- Screw-type system 6ES7292-1AL40-0XA0
- Push-in system 6ES7292-2AL40-0XA0
For 6ES7223-1QH32-0XB0
• 7-pin, tin-coated, right coded;
4 units
- Screw-type system 6ES7292-1AG40-0XA0
- Push-in system 6ES7292-2AG40-0XA0
Front flap set (spare part)
For modules with a width of 45 mm 6ES7291-1BA30-0XA0
For modules with a width of 70 mm 6ES7291-1BB30-0XA0
■ Technical specifications
Article number 6ES7223-1BH32- 6ES7223-1BL32- 6ES7223-1BL32- 6ES7223-1PH32- 6ES7223-1PL32- 6ES7223-1QH32-
0XB0 0XB0 1XB0 0XB0 0XB0 0XB0
Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
SM 1223, SM 1223, SM 1223, SM 1223, SM 1223, SM 1223,
8 DI/8 DO 16DI/16DO 16DI/16DO 8DI/8DO 16DI/16DO 8DI AC/ 8DO
General information
sink Rly
3
Product type designation SM 1223, SM 1223, SM 1223, SM 1223, SM 1223, SM 1223,
DI 8x24 V DC, DI 16x24 V DC, DI 16x24 V DC, DI 8x24 V DC, DI 16x24 V DC, DI 8x120/230 V AC,
DQ 8x24 V DC DQ 16x24 V DC DO 16x 24 V DC DQ 8x relay DQ 16x relay DQ 8x relay
Sink
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V 24 V 24 V
Input current
from backplane bus 5 V DC, max. 145 mA 185 mA 185 mA 145 mA 180 mA 120 mA
Digital inputs
• from load voltage L+ (without load), 4 mA; per channel 4 mA; per channel 4 mA; per channel 4 mA/input 4 mA/input
max. 11 mA/relay 11 mA/relay
Output voltage
Power supply to the transmitters
• present Yes Yes Yes Yes Yes Yes
Digital inputs
Number of digital inputs 8 16 16 8 16 8
• in groups of 2 2 2 2 2 4
Input characteristic curve in Yes Yes Yes Yes Yes Yes
accordance with IEC 61131, type 1
Number of simultaneously
controllable inputs
all mounting positions
- up to 40 °C, max. 8 16 16 8 16 8
horizontal installation
- up to 40 °C, max. 8 16 16 8 16 8
- up to 50 °C, max. 8 16 16 8 16 8
vertical installation
- up to 40 °C, max. 8 16 16 8 16 8
Input voltage
• Type of input voltage DC DC DC DC DC AC
• Rated value (DC) 24 V 24 V 24 V 24 V 24 V
• Rated value (AC) 120/230 V AC
• for signal "0" 5 V DC at 1 mA 5 V DC at 1 mA 5 V DC at 1 mA 5 V DC at 1 mA 5 V DC at 1 mA 20 V AC at 1 mA
• for signal "1" 15 V DC at 2.5 mA 15 V DC at 2.5 mA 15 V DC at 2.5 mA 15 V DC at 2.5 mA 15 V DC at 2.5 mA 79 V AC at 2.5 mA
Input current
• for signal "0", max. 1 mA 1 mA 1 mA 1 mA 1 mA 1 mA
(permissible quiescent current)
• for signal "1", min. 2.5 mA 2.5 mA 2.5 mA 2.5 mA 2.5 mA 2.5 mA
• for signal "1", typ. 4 mA 4 mA 4 mA 4 mA 4 mA 9 mA
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.2 ms, 0.4 ms, Yes; 0.2 ms, 0.4 ms, Yes; 0.2 ms, 0.4 ms, Yes; 0.2 ms, 0.4 ms, Yes; 0.2 ms, 0.4 ms, Yes; 0.2 ms, 0.4 ms,
0.8 ms, 1.6 ms, 0.8 ms, 1.6 ms, 0.8 ms, 1.6 ms, 0.8 ms, 1.6 ms, 0.8 ms, 1.6 ms, 0.8 ms, 1.6 ms,
3.2 ms, 6.4 ms and 3.2 ms, 6.4 ms and 3.2 ms, 6.4 ms and 3.2 ms, 6.4 ms and 3.2 ms, 6.4 ms and 3.2 ms, 6.4 ms and
12.8 ms, selectable 12.8 ms, selectable 12.8 ms, selectable 12.8 ms, selectable 12.8 ms, selectable 12.8 ms, selectable
in groups of four in groups of four in groups of four in groups of four in groups of four in groups of four
for interrupt inputs
- parameterizable Yes Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7223-1BH32- 6ES7223-1BL32- 6ES7223-1BL32- 6ES7223-1PH32- 6ES7223-1PL32- 6ES7223-1QH32-
0XB0 0XB0 1XB0 0XB0 0XB0 0XB0
Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
SM 1223, SM 1223, SM 1223, SM 1223, SM 1223, SM 1223,
8 DI/8 DO 16DI/16DO 16DI/16DO 8DI/8DO 16DI/16DO 8DI AC/ 8DO
3 Digital outputs
sink Rly
■ Technical specifications
Article number 6ES7223-1BH32- 6ES7223-1BL32- 6ES7223-1BL32- 6ES7223-1PH32- 6ES7223-1PL32- 6ES7223-1QH32-
0XB0 0XB0 1XB0 0XB0 0XB0 0XB0
Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
SM 1223, SM 1223, SM 1223, SM 1223, SM 1223, SM 1223,
8 DI/8 DO 16DI/16DO 16DI/16DO 8DI/8DO 16DI/16DO 8DI AC/ 8DO
Potential separation
sink Rly
3
Potential separation digital inputs
• between the channels, in groups of 2 2 2 2 2 2
Potential separation digital outputs
• between the channels Relays Relays Relays
• between the channels, in groups of 1 1 1 2 4 2
• between the channels and 500 V AC 500 V AC 500 V AC 1 500 V AC for 1 500 V AC for 1 500 V AC for
backplane bus 1 minute 1 minute 1 minute
Standards, approvals, certificates
CE mark Yes Yes Yes Yes Yes Yes
CSA approval Yes Yes Yes Yes Yes Yes
UL approval Yes Yes Yes Yes Yes Yes
cULus Yes Yes Yes Yes Yes Yes
FM approval Yes Yes Yes Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes Yes Yes Yes
KC approval Yes Yes Yes Yes Yes Yes
Marine approval Yes Yes Yes Yes Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C 60 °C 60 °C; Number of 60 °C; Number of
simultaneously simultaneously
activated outputs: activated outputs:
8 (no adjacent 4 (no adjacent
points) at 60 °C points) at 60 °C
horizontal or 50 °C horizontal or 50 °C
vertical, 16 at vertical, 8 at 55 °C
55 °C horizontal or horizontal or 45 °C
45 °C vertical vertical
Connection method
required front connector Yes Yes Yes Yes Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes Yes Yes Yes Yes
Dimensions
Width 45 mm 70 mm 70 mm 45 mm 70 mm 45 mm
Height 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm
Weights
Weight, approx. 210 g 310 g 310 g 230 g 350 g 230 g
3
2 x 24 V DC transistor outputs,
0.5 A, 5 W;
can be used as HSC at
up to 30 kHz
2 inputs, 5 V DC, 200 kHz 6ES7223-3AD30-0XB0
2 outputs 5 V DC, 0.1 A, 200 kHz
2 inputs, 24 V DC, 200 kHz 6ES7223-3BD30-0XB0
2 outputs 24 V DC, 0.1 A, 200 kHz
Terminal block (spare part)
for signal board
with 6 screws, gold-plated; 4 pcs. 6ES7292-1BF30-0XA0
■ Technical specifications
Article number 6ES7223-0BD30-0XB0 6ES7223-3AD30-0XB0 6ES7223-3BD30-0XB0
Signal Board SB1223, 2 DI/2 DO Signal Board SB 1223, Signal Board SB 1223,
2DI/2DQ 5V 200KHz 2DI/2DQ 24V 200KHz
General information
Product type designation SB 1223, DI 2x24 V DC/ SB 1223, DI 2x5 V DC/ SB 1223, DI 2x24 V DC/
DQ 2x24 V DC DQ 2x5 V DC 200 kHz DQ 2x24 V DC 200 kHz
Input current
from backplane bus 5 V DC, typ. 50 mA 35 mA 35 mA
Output voltage
Power supply to the transmitters
• Supply current, max. 4 mA; per channel
Digital inputs
Number of digital inputs 2; Current-sinking 2; Current-sourcing 2; Current-sourcing
• in groups of 1 2 2
Input characteristic curve in Yes
accordance with IEC 61131, type 1
Number of simultaneously
controllable inputs
all mounting positions
- up to 40 °C, max. 2 2
Input voltage
• Type of input voltage DC DC DC
• Rated value (DC) 24 V 5V 24 V
• for signal "0" 0 to 5 V (L+ minus 1.0 V DC) ... L+ (L+ minus 5.0 V DC) ... L+
• for signal "1" +15 to +30 V 0 V ... (L+ minus 2.0 V DC) 0 V ... (L+ minus 10 V DC)
Input current
• for signal "0", max. (permissible 1 mA 2.2 mA 1.4 mA
quiescent current)
• for signal "1", min. 5.1 mA 2.9 mA
• for signal "1", typ. 0.5 A 7 mA
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 /
3.2 ms, 6.4 ms and 12.8 ms, selectable 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 /
in groups of four 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 /
20.0 ms 20.0 ms
for interrupt inputs
- parameterizable Yes Yes Yes
for technological functions
- parameterizable Yes Yes Yes
■ Technical specifications
Article number 6ES7223-0BD30-0XB0 6ES7223-3AD30-0XB0 6ES7223-3BD30-0XB0
Signal Board SB1223, 2 DI/2 DO Signal Board SB 1223, Signal Board SB 1223,
2DI/2DQ 5V 200KHz 2DI/2DQ 24V 200KHz
Digital outputs
Number of digital outputs 2; MOSFET, solid-state
(current-sinking/current-sourcing)
2; MOSFET, solid-state
(current-sinking/current-sourcing)
2; MOSFET, solid-state
(current-sinking/current-sourcing) 3
• in groups of 1 2 2
Short-circuit protection No No No
Switching capacity of the outputs
• with resistive load, max. 0.5 A 0.1 A 0.1 A
• on lamp load, max. 5W
Load resistance range
• upper limit 0.6 Ω 7Ω
Output voltage
• Rated value (DC) 24 V 5V 24 V
• for signal "0", max. 0.1 V; with 10 kOhm load 0.2 V 1V
• for signal "1", min. 20 V L+ minus 0.7 V DC L+ (-1.5 V)
• for signal "1", max. 6V
Output current
• for signal "1" permissible range, 0.5 A 0.1 A 0.1 A
max.
• for signal "0" residual current, max. 10 µA
Interrupts/diagnostics/
status information
Alarms Yes
Diagnostics function Yes
Diagnostics indication LED
• for status of the inputs Yes Yes Yes
• for status of the outputs Yes Yes Yes
Standards, approvals, certificates
CE mark Yes Yes Yes
CSA approval Yes Yes Yes
UL approval Yes Yes Yes
cULus Yes Yes Yes
FM approval Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes
KC approval Yes Yes Yes
Marine approval Yes Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes Yes
Dimensions
Width 38 mm 38 mm 38 mm
Height 62 mm 62 mm 62 mm
Depth 21 mm 21 mm 21 mm
Weights
Weight, approx. 40 g 35 g 35 g
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1221-1BF32-2XB0 6AG1221-1BF32-4XB0 6AG1221-1BH32-2XB0 6AG1221-1BH32-4XB0
Based on 6ES7221-1BF32-0XB0 6ES7221-1BF32-0XB0 6ES7221-1BH32-0XB0 6ES7221-1BH32-0XB0
SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221
8DI 8DI 16DI 16DI
Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin -20 °C; = Tmin -40 °C; = Tmin -20 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ 0 °C start-up @ -25 °C start-up @ 0 °C
• max. 70 °C; = Tmax; 60 °C; = Tmax 70 °C; = Tmax; 60 °C; = Tmax
Tmax > +60 °C number of Tmax > +60 °C number of
simultaneously activated simultaneously activated
inputs 4 (no adjacent points) inputs 8 (no adjacent points)
for horizontal mounting for horizontal mounting
position position
• At cold restart, min. -25 °C 0 °C -25 °C 0 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
■ Technical specifications
Article number 6AG1221-1BF32-2XB0 6AG1221-1BF32-4XB0 6AG1221-1BH32-2XB0 6AG1221-1BH32-4XB0
Based on 6ES7221-1BF32-0XB0 6ES7221-1BF32-0XB0 6ES7221-1BH32-0XB0 6ES7221-1BH32-0XB0
SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221 SIPLUS S7-1200 SM 1221
8DI 8DI 16DI 16DI
Resistance
Coolants and lubricants
3
- Resistant to commercially Yes Yes Yes Yes
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores fungal spores fungal spores fungal spores
(excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna);
Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 permissible); level LC3 permissible); level LC3 permissible); level LC3
(salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3
(oil) (oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1221-3AD30-5XB0 6AG1221-3BD30-5XB0
Based on 6ES7221-3AD30-0XB0 6ES7221-3BD30-0XB0
SIPLUS S7-1200 SB 1221 4DI 5VDC SIPLUS S7-1200 SB 1221 4DI 24VDC
Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
• max. 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation / frost (no commissioning in 100 %; RH incl. condensation / frost (no commissioning in
accordance with IEC 60068-2-38, bedewed state), horizontal installation bedewed state), horizontal installation
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Technical specifications
Article number 6AG1221-3AD30-5XB0 6AG1221-3BD30-5XB0
Based on 6ES7221-3AD30-0XB0 6ES7221-3BD30-0XB0
SIPLUS S7-1200 SB 1221 4DI 5VDC SIPLUS S7-1200 SB 1221 4DI 24VDC
Use on ships/at sea
- to biologically active substances
according to EN 60721-3-6
Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
Class 6B3 on request Class 6B3 on request
3
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1222-1BF32-2XB0 6AG1222-1BF32-4XB0 6AG1222-1BH32-2XB0 6AG1222-1BH32-4XB0
Based on 6ES7222-1BF32-0XB0 6ES7222-1BF32-0XB0 6ES7222-1BH32-0XB0 6ES7222-1BH32-0XB0
SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222
8DQ 8DQ 16DQ 16DQ
Ambient conditions
Ambient temperature during
3
operation
• min. -40 °C; = Tmin (incl. -20 °C; = Tmin (incl. -40 °C; = Tmin (incl. -20 °C; = Tmin (incl.
condensation/frost); condensation/frost); condensation/frost); condensation/frost);
start-up @ -25 °C start-up @ 0 °C start-up @ -25 °C start-up @ 0 °C
• max. 70 °C; = Tmax; 60 °C; = Tmax 70 °C; = Tmax; 60 °C; = Tmax
Tmax > +60 °C number of Tmax > +60 °C number of
simultaneously activated simultaneously activated
outputs 4 (no adjacent outputs 8 (no adjacent
points) for horizontal points) for horizontal
mounting position mounting position
• At cold restart, min. -25 °C 0 °C -25 °C 0 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1222-1BF32-2XB0 6AG1222-1BF32-4XB0 6AG1222-1BH32-2XB0 6AG1222-1BH32-4XB0
Based on 6ES7222-1BF32-0XB0 6ES7222-1BF32-0XB0 6ES7222-1BH32-0XB0 6ES7222-1BH32-0XB0
SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222
8DQ 8DQ 16DQ 16DQ
■ Technical specifications
Article number 6AG1222-1HF32-2XB0 6AG1222-1HF32-4XB0 6AG1222-1XF32-2XB0 6AG1222-1XF32-4XB0
Based on 6ES7222-1HF32-0XB0 6ES7222-1HF32-0XB0 6ES7222-1XF32-0XB0 6ES7222-1XF32-0XB0
SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222 SIPLUS S7-1200 SM 1222
8DQ RLY 8DQ RLY 8DQ RLY 8DQ RLY
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
3
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 permissible); level LC3 permissible); level LC3 permissible); level LC3
(salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3
(oil) (oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1222-1HH32-2XB0 6AG1222-1HH32-4XB0
Based on 6ES7222-1HH32-0XB0 6ES7222-1HH32-0XB0
SIPLUS S7-1200 SM 1222 16DQ RLY SIPLUS S7-1200 SM 1222 16DQ RLY
Ambient conditions
3 Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
• max. 70 °C; = Tmax; Tmax > +60 °C number of simultaneously 60 °C; = Tmax
activated outputs 8 (no adjacent points) for horizontal
mounting position
• At cold restart, min. -25 °C 0 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC (+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under condensation conditions) (no commissioning under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1222-1AD30-5XB0 6AG1222-1BD30-5XB0
Based on 6ES7222-1AD30-0XB0 6ES7222-1BD30-0XB0
SIPLUS S7-1200 SB 1222 4DQ 5VDC SIPLUS S7-1200 SB 1222 4DQ 24VDC
Ambient conditions
3 Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
• max. 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation / frost (no commissioning in 100 %; RH incl. condensation / frost (no commissioning in
accordance with IEC 60068-2-38, bedewed state), horizontal installation bedewed state), horizontal installation
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1223-1BH32-2XB0 6AG1223-1BH32-4XB0 6AG1223-1PH32-2XB0 6AG1223-1PH32-4XB0
Based on 6ES7223-1BH32-0XB0 6ES7223-1BH32-0XB0 6ES7223-1PH32-0XB0 6ES7223-1PH32-0XB0
SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223
8DI/8DQ 8DI/8DQ 8DI/8DQ RLY 8DI/8DQ RLY
3 Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin -20 °C; = Tmin -40 °C; = Tmin -20 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ 0 °C start-up @ -25 °C start-up @ 0 °C
• max. 70 °C; = Tmax; 60 °C; = Tmax 70 °C; = Tmax; 60 °C; = Tmax
Tmax > +60 °C number of Tmax > +60 °C number of
simultaneously activated simultaneously activated
outputs 4, inputs 4 outputs 4, inputs 4
(no adjacent points) for (no adjacent points) for
horizontal mounting position horizontal mounting position
• At cold restart, min. -25 °C 0 °C -25 °C 0 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax - 20 K) at Tmin ... (Tmax - 20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m); (+3 500 m ... +5 000 m);
above 2 000 m max. 132 V AC above 2 000 m max. 132 V AC
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes Yes Yes Yes
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1223-1BH32-2XB0 6AG1223-1BH32-4XB0 6AG1223-1PH32-2XB0 6AG1223-1PH32-4XB0
Based on 6ES7223-1BH32-0XB0 6ES7223-1BH32-0XB0 6ES7223-1PH32-0XB0 6ES7223-1PH32-0XB0
SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223
8DI/8DQ 8DI/8DQ 8DI/8DQ RLY 8DI/8DQ RLY
Usage in industrial process
technology 3
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 permissible); level LC3 permissible); level LC3 permissible); level LC3
(salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3
(oil) (oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1223-1PL32-2XB0 6AG1223-1PL32-4XB0 6AG1223-1BL32-2XB0 6AG1223-1BL32-4XB0
Based on 6ES7223-1PL32-0XB0 6ES7223-1PL32-0XB0 6ES7223-1BL32-0XB0 6ES7223-1BL32-0XB0
SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223 SIPLUS S7-1200 SM 1223
16DI/16DQ RLY 16DI/16DQ RLY 16DI/16DQ 16DI/16DQ
■ Technical specifications
Article number 6AG1223-1QH32-2XB0 6AG1223-1QH32-4XB0
Based on 6ES7223-1QH32-0XB0 6ES7223-1QH32-0XB0
SIPLUS S7-1200 SM 1223 8DI AC/8DQ RLY SIPLUS S7-1200 SM 1223 8DI AC/8DQ RLY
Ambient conditions
Ambient temperature during
operation
3
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
• max. 70 °C; = Tmax; Tmax > +60 °C number of simultaneously 60 °C; = Tmax
activated outputs 4, inputs 4 (no adjacent points)
for horizontal mounting position
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 080 hPa ... 795 hPa Tmin ... Tmax at 1 080 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
3 2 inputs, 24 V DC,
IEC type 1 sinking input;
2 x 24 V DC transistor outputs,
0.5 A, 5 W;
can be used as HSC at up to
30 kHz
• Suitable for areas with extreme 6AG1223-0BD30-4XB0
exposure to media (conformal
coating)
• Ambient temperature 6AG1223-0BD30-5XB0
-25 ... +55 °C
2 inputs, 5 V DC, 200 kHz 6AG1223-3AD30-5XB0
2 outputs 5 V DC, 0.1 A, 200 kHz
2 inputs, 24 V DC, 200 kHz 6AG1223-3BD30-5XB0
2 outputs 24 V DC, 0.1 A, 200 kHz
• Digital inputs and outputs as supplement to the integral I/O of Accessories See SIMATIC S7-1200 digital
the SIPLUS S7-1200 CPUs input/output SB 1223, page 3/62
• Can be plugged directly into the CPU (cannot be used for
+70 °C version)
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1223-0BD30-4XB0 6AG1223-0BD30-5XB0 6AG1223-3AD30-5XB0 6AG1223-3BD30-5XB0
Based on 6ES7223-0BD30-0XB0 6ES7223-0BD30-0XB0 6ES7223-3AD30-0XB0 6ES7223-3BD30-0XB0
SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223
2DI/2DQ 24VDC 2DI/2DQ 24VDC 2DI/2DQ 5VDC 2DI/2DQ, 24VDC
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost) (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ -25 °C start-up @ -25 °C
• max. 60 °C; = Tmax 60 °C; = Tmax 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost permitted condensation / frost condensation / frost condensation / frost
max. (no commissioning in (no commissioning in (no commissioning in (no commissioning in
bedewed state) bedewed state), horizontal bedewed state), horizontal bedewed state), horizontal
installation installation installation
■ Technical specifications
Article number 6AG1223-0BD30-4XB0 6AG1223-0BD30-5XB0 6AG1223-3AD30-5XB0 6AG1223-3BD30-5XB0
Based on 6ES7223-0BD30-0XB0 6ES7223-0BD30-0XB0 6ES7223-3AD30-0XB0 6ES7223-3BD30-0XB0
SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223 SIPLUS S7-1200 SB 1223
2DI/2DQ 24VDC 2DI/2DQ 24VDC 2DI/2DQ 5VDC 2DI/2DQ, 24VDC
Resistance
Coolants and lubricants
3
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 permissible); level LC3 permissible); level LC3 permissible); level LC3
(salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3
(oil) (oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6ES7231-4HD32-0XB0 6ES7231-4HF32-0XB0 6ES7231-5ND32-0XB0
Analog Input SM 1231, 4AI Analog Input SM 1231, 8AI Analog Input SM 1231, 4AI 16bit
General information
Product type designation SM 1231, AI 4x13 bit SM 1231, AI 8x13 bit SM 1231, AI 4x16 bit
Supply voltage
Rated value (DC) 24 V 24 V 24 V
Input current
Current consumption, typ. 45 mA 45 mA 65 mA
from backplane bus 5 V DC, typ. 80 mA 90 mA 80 mA
Analog inputs
Number of analog inputs 4; Current or voltage differential inputs 8; Current or voltage differential inputs 4; Current or voltage differential inputs
permissible input voltage for voltage 35 V 35 V ±35 V
input (destruction limit), max.
permissible input current for current 40 mA 40 mA 40 mA
input (destruction limit), max.
Cycle time (all channels) max. 625 µs 625 µs 100 µs
Input ranges
• Voltage Yes; ±10V, ±5V, ±2.5V Yes; ±10V, ±5V, ±2.5V Yes; ±10V, ±5V, ±2.5V or ±1.25V
• Current Yes; 4 to 20 mA, 0 to 20 mA Yes; 4 to 20 mA, 0 to 20 mA Yes; 4 to 20 mA, 0 to 20 mA
• Thermocouple No No No
• Resistance thermometer No No No
• Resistance No Yes No
Input ranges (rated values),
voltages
• -1.25 V to +1.25 V Yes
• -10 V to +10 V Yes Yes Yes
• -2.5 V to +2.5 V Yes Yes Yes
• -5 V to +5 V Yes Yes Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes Yes Yes
• 4 mA to 20 mA Yes Yes Yes
Thermocouple (TC)
Temperature compensation
- parameterizable No
■ Technical specifications
Article number 6ES7231-4HD32-0XB0 6ES7231-4HF32-0XB0 6ES7231-5ND32-0XB0
Analog Input SM 1231, 4AI Analog Input SM 1231, 8AI Analog Input SM 1231, 4AI 16bit
Analog value generation
for the inputs
Integration and conversion
time/resolution per channel 3
• Resolution with overrange 12 bit; + sign 12 bit; + sign 15 bit; + sign
(bit including sign), max.
• Integration time, parameterizable Yes Yes Yes
• Interference voltage suppression 40 dB, DC to 60 V for interference 40 dB, DC to 60 V for interference 40 dB, DC to 60 V for interference
for interference frequency f1 in Hz frequency 50 / 60 Hz frequency 50 / 60 Hz frequency 50 / 60 Hz
Smoothing of measured values
• parameterizable Yes Yes Yes
Errors/accuracies
Temperature error 25 °C ±0.1%, to 55 °C ±0.2% total 25 °C ±0.1%, to 55 °C ±0.2% total 25 °C ±0.1% / ±0.3% total
(relative to input range), (+/-) measurement range measurement range measurement range
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input range, (+/-) 0.1 % 0.1 % 0.1 %
• Current, relative to input range, (+/-) 0.1 % 0.1 % 0.1 %
Interference voltage suppression for
f = n x (f1 +/- 1 %),
f1 = interference frequency
• Common mode voltage, max. 12 V 12 V 12 V
Interrupts/diagnostics/
status information
Alarms Yes Yes Yes
Diagnostics function Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes Yes
Diagnoses
• Monitoring the supply voltage Yes Yes Yes
• Wire-break Yes Yes Yes
Diagnostics indication LED
• for status of the inputs Yes Yes Yes
• for maintenance Yes Yes Yes
Standards, approvals, certificates
CE mark Yes Yes Yes
CSA approval Yes Yes Yes
UL approval Yes Yes Yes
cULus Yes Yes Yes
FM approval Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes
KC approval Yes Yes Yes
Marine approval Yes Yes Yes
■ Technical specifications
Article number 6ES7231-4HD32-0XB0 6ES7231-4HF32-0XB0 6ES7231-5ND32-0XB0
Analog Input SM 1231, 4AI Analog Input SM 1231, 8AI Analog Input SM 1231, 4AI 16bit
Ambient conditions
Ambient temperature during
3 operation
• min. -20 °C -20 °C -20 °C
• max. 60 °C 60 °C 60 °C
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free RH < 60% condensation-free
Connection method
required front connector Yes Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes Yes
Dimensions
Width 45 mm 45 mm 45 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 180 g 180 g 180 g
■ Technical specifications
Article number 6ES7231-4HA30-0XB0 Article number 6ES7231-4HA30-0XB0
Signal Board SB 1231, 1 AI Signal Board SB 1231, 1 AI
General information Errors/accuracies
Product type designation SB 1231, AI 1x12 bit Temperature error 25 °C ±0.3%, to 55 °C ±0.6% total
Supply voltage (relative to input range), (+/-) measurement range
Rated value (DC) 24 V Interrupts/diagnostics/
status information
Input current
Alarms Yes
from backplane bus 5 V DC, typ. 55 mA
Diagnostics function Yes
Analog inputs
Alarms
Number of analog inputs 1; Current or voltage differential
inputs • Diagnostic alarm Yes
permissible input voltage for current ±35 V Diagnoses
input (destruction limit), max. • Wire-break No
permissible input voltage for voltage 35 V Diagnostics indication LED
input (destruction limit), max. • for status of the inputs Yes
permissible input current for voltage 40 mA • for maintenance Yes
input (destruction limit), max.
Standards, approvals, certificates
permissible input current for current 40 mA
input (destruction limit), max. CE mark Yes
Cycle time (all channels) max. 156.25 µs; 400 Hz suppression CSA approval Yes
Input ranges UL approval Yes
• Voltage Yes; ±10V, ±5V, ±2.5V cULus Yes
• Current Yes; 0 to 20 mA FM approval Yes
• Thermocouple No RCM (formerly C-TICK) Yes
• Resistance thermometer No KC approval Yes
• Resistance No Marine approval Yes
Input ranges (rated values), Ambient conditions
voltages Ambient temperature during
• -10 V to +10 V Yes operation
• -2.5 V to +2.5 V Yes • min. -20 °C
• -5 V to +5 V Yes • max. 60 °C
Input ranges (rated values), currents Pollutant concentrations
• 0 to 20 mA Yes • SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free
Analog outputs
Connection method
Number of analog outputs 0
required front connector Yes
Cable length
Mechanics/material
• shielded, max. 100 m; shielded, twisted pair
Enclosure material (front)
Analog value generation for the
inputs • Plastic Yes
Integration and conversion Dimensions
time/resolution per channel Width 38 mm
• Resolution with overrange 11 bit; + sign Height 62 mm
(bit including sign), max.
Depth 21 mm
• Integration time, parameterizable Yes
Weights
• Interference voltage suppression for 40 dB, DC to 60 Hz
interference frequency f1 in Hz Weight, approx. 35 g
Smoothing of measured values
• parameterizable Yes
■ Technical specifications
Article number 6ES7232-4HB32-0XB0 6ES7232-4HD32-0XB0
Analog Output SM 1232, 2AO Analog Output SM 1232, 4AO
General information
Product type designation SM 1232, AQ 2x14 bit SM 1232, AQ 4x14 bit
Supply voltage
Rated value (DC) 24 V 24 V
Input current
Current consumption, typ. 45 mA 45 mA
from backplane bus 5 V DC, typ. 80 mA 80 mA
Analog outputs
Number of analog outputs 2; Current or voltage 4; Current or voltage
Output ranges, voltage
• -10 V to +10 V Yes Yes
Output ranges, current
• 0 to 20 mA Yes Yes
Load impedance
(in rated range of output)
• with voltage outputs, min. 1 000 Ω 1 000 Ω
• with current outputs, max. 600 Ω 600 Ω
Cable length
• shielded, max. 100 m; shielded, twisted pair 100 m; shielded, twisted pair
Analog value generation for
the outputs
Integration and conversion
time/resolution per channel
• Resolution with overrange 14 bit; Voltage: 14 bit; Current : 13 bit 14 bit; Voltage: 14 bit; Current : 13 bit
(bit including sign), max.
Errors/accuracies
Temperature error 25 °C ±0.3%, to 55 °C ±0.6% total measurement range 25 °C ±0.3%, to 55 °C ±0.6% total measurement range
(relative to output range), (+/-)
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to output range, (+/-) 0.3 % 0.3 %
• Current, relative to output range, (+/-) 0.3 % 0.3 %
Interference voltage suppression for
f = n x (f1 +/- 1 %),
f1 = interference frequency
• Common mode voltage, max. 12 V 12 V
■ Technical specifications
Article number 6ES7232-4HB32-0XB0 6ES7232-4HD32-0XB0
Analog Output SM 1232, 2AO Analog Output SM 1232, 4AO
Interrupts/diagnostics/
status information
Alarms
Diagnostics function
Yes
Yes
Yes
Yes
3
Alarms
• Diagnostic alarm Yes Yes
Diagnoses
• Monitoring the supply voltage Yes Yes
• Wire-break Yes Yes
• Short-circuit Yes Yes
Diagnostics indication LED
• for status of the outputs Yes Yes
• for maintenance Yes Yes
Standards, approvals, certificates
CE mark Yes Yes
CSA approval Yes Yes
UL approval Yes Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free
Connection method
required front connector Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes
Dimensions
Width 45 mm 45 mm
Height 100 mm 100 mm
Depth 75 mm 75 mm
Weights
Weight, approx. 180 g 180 g
■ Technical specifications
Article number 6ES7232-4HA30-0XB0 Article number 6ES7232-4HA30-0XB0
Signal Board SB 1232, 1 AO Signal Board SB 1232, 1 AO
General information Interrupts/diagnostics/
Product type designation SB 1232, AQ 1x12 bit status information
Input current Alarms Yes
from backplane bus 5 V DC, typ. 15 mA Diagnostics function Yes
Output voltage Diagnostics indication LED
Power supply to the transmitters • for status of the outputs Yes
• Supply current, max. 25 mA Standards, approvals, certificates
Analog inputs CE mark Yes
Number of analog inputs 0 CSA approval Yes
Analog outputs UL approval Yes
Number of analog outputs 1 cULus Yes
Cycle time (all channels) max. Voltage: 300 μS (R), 750 μS (1 uF) FM approval Yes
Current: 600 ms (1 mH); 2 ms (10 mH) RCM (formerly C-TICK) Yes
Output ranges, voltage KC approval Yes
• -10 V to +10 V Yes Marine approval Yes
Output ranges, current Ambient conditions
• 0 to 20 mA Yes Ambient temperature during
Load impedance operation
(in rated range of output) • min. -20 °C
• with voltage outputs, min. 1 000 Ω • max. 60 °C
• with current outputs, max. 600 Ω Pollutant concentrations
Cable length • SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm;
• shielded, max. 100 m; shielded, twisted pair condensation RH < 60% condensation-free
Analog value generation Mechanics/material
for the outputs Enclosure material (front)
Conversion principle Differential • Plastic Yes
Integration and conversion Dimensions
time/resolution per channel Width 38 mm
• Resolution with overrange 12 bit Height 62 mm
(bit including sign), max.
Depth 21 mm
Errors/accuracies
Weights
Temperature error 25 °C ±0.5%, to 55 °C ±1%
(relative to output range), (+/-) Weight, approx. 40 g
3
2 analog outputs, ±10 V with 14 bits
or 0 ... 20 mA with 13 bits
Terminal block (spare part)
For 6ES7234-4HE32-0XB0
• 7-pin, gold-plated; 4 units
- Screw-type system 6ES7292-1BG30-0XA0
- Push-in system 6ES7292-2BG30-0XA0
Extension cable for two-tier 6ES7290-6AA30-0XA0
configuration
For connecting digital/analog signal
modules; length 2 m
Front flap set (spare part)
For modules with a width of 45 mm 6ES7291-1BA30-0XA0
■ Technical specifications
Article number 6ES7234-4HE32-0XB0 Article number 6ES7234-4HE32-0XB0
Analog I/O SM 1234, 4AI/2AO Analog I/O SM 1234, 4AI/2AO
General information Analog outputs
Product type designation SM 1234, AI 4x13 bit/AQ 2x14 bit Number of analog outputs 2; Current or voltage
Supply voltage Output ranges, voltage
Rated value (DC) 24 V • -10 V to +10 V Yes
Input current Output ranges, current
Current consumption, typ. 60 mA • 0 to 20 mA Yes
from backplane bus 5 V DC, typ. 80 mA • 4 mA to 20 mA Yes
Analog inputs Load impedance
Number of analog inputs 4; Current or voltage differential (in rated range of output)
inputs • with voltage outputs, min. 1 000 Ω
permissible input voltage for voltage 35 V • with current outputs, max. 600 Ω
input (destruction limit), max. Cable length
permissible input current for current 40 mA • shielded, max. 100 m; shielded, twisted pair
input (destruction limit), max.
Analog value generation
Cycle time (all channels) max. 625 µs for the inputs
Input ranges Integration and conversion
• Voltage Yes; ±10V, ±5V, ±2.5V time/resolution per channel
• Current Yes; 4 to 20 mA, 0 to 20 mA • Resolution with overrange 12 bit; + sign
Input ranges (rated values), (bit including sign), max.
voltages • Integration time, parameterizable Yes
• -10 V to +10 V Yes • Interference voltage suppression for 40 dB, DC to 60 V for interference
• -2.5 V to +2.5 V Yes interference frequency f1 in Hz frequency 50 / 60 Hz
• -5 V to +5 V Yes Smoothing of measured values
Input ranges (rated values), currents • parameterizable Yes
• 0 to 20 mA Yes Analog value generation
for the outputs
• 4 mA to 20 mA Yes
Integration and conversion
time/resolution per channel
• Resolution with overrange 14 bit; Voltage: 14 bit; Current : 13 bit
(bit including sign), max.
■ Technical specifications
Article number 6ES7234-4HE32-0XB0 Article number 6ES7234-4HE32-0XB0
Analog I/O SM 1234, 4AI/2AO Analog I/O SM 1234, 4AI/2AO
Errors/accuracies Standards, approvals, certificates
Temperature error (relative to input 25 °C ±0.1%, to 55 °C ±0.2% CE mark Yes
3 range), (+/-)
Temperature error (relative to output
total measurement range
25 °C ±0.3%, to 55 °C ±0.6%
CSA approval
UL approval
Yes
Yes
range), (+/-) total measurement range
cULus Yes
Basic error limit
(operational limit at 25 °C) FM approval Yes
• Voltage, relative to input range, (+/-) 0.1 % RCM (formerly C-TICK) Yes
• Current, relative to input range, (+/-) 0.1 % KC approval Yes
• Voltage, relative to output range, (+/-) 0.3 % Marine approval Yes
• Current, relative to output range, (+/-) 0.3 % Ambient conditions
Interference voltage suppression for Ambient temperature during
f = n x (f1 +/- 1 %), operation
f1 = interference frequency • min. -20 °C
• Common mode voltage, max. 12 V • max. 60 °C
Interrupts/diagnostics/ Pollutant concentrations
status information
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm;
Alarms Yes condensation RH < 60% condensation-free
Diagnostics function Yes Connection method
Alarms required front connector Yes
• Diagnostic alarm Yes Mechanics/material
Diagnoses Enclosure material (front)
• Monitoring the supply voltage Yes • Plastic Yes
• Wire-break Yes Dimensions
• Short-circuit Yes Width 45 mm
Diagnostics indication LED Height 100 mm
• for status of the inputs Yes Depth 75 mm
• for status of the outputs Yes Weights
• for maintenance Yes Weight, approx. 220 g
Potential separation analog outputs
• between the channels and the No
power supply of the electronics
■ Overview
• For the convenient recording of temperatures with great • Also for the measurement of analog signals with a low level
accuracy (±80 mV)
• 7 common thermocouple types can be used • Can easily be retrofitted to existing plant
■ Technical specifications
Article number 6ES7231-5QD32-0XB0 6ES7231-5QF32-0XB0
S7-1200, analog Input SM 1231 TC, 4 AI S7-1200, analog Input SM 1231 TC, 8 AI
General information
Product type designation SM 1231, AI 4x16 bit TC SM 1231, AI 8x16 bit TC
Supply voltage
Rated value (DC) 24 V 24 V
Input current
Current consumption, typ. 40 mA 40 mA
from backplane bus 5 V DC, typ. 80 mA 80 mA
Analog inputs
Number of analog inputs 4; Thermocouples 8; Thermocouples
Technical unit for temperature Degrees Celsius/degrees Fahrenheit Degrees Celsius/degrees Fahrenheit
measurement adjustable
Input ranges
• Voltage Yes Yes
• Current No No
• Thermocouple Yes; J, K, T, E, R, S, N, C, TXK/XK(L); Yes; J, K, T, E, R & S, B, N, C, TXK/XK(L);
voltage range: ±80 mV voltage range: ±80 mV
• Resistance thermometer No No
• Resistance No No
Input ranges (rated values),
voltages
• -80 mV to +80 mV Yes Yes
Input ranges (rated values),
thermocouples
• Type B Yes Yes
• Type C Yes Yes
• Type E Yes Yes
• Type J Yes Yes
• Type K Yes Yes
• Type N Yes Yes
• Type R Yes Yes
• Type S Yes Yes
• Type T Yes Yes
• Type TXK/TXK(L) to GOST Yes Yes
Thermocouple (TC)
Temperature compensation
- parameterizable No No
■ Technical specifications
Article number 6ES7231-5QD32-0XB0 6ES7231-5QF32-0XB0
S7-1200, analog Input SM 1231 TC, 4 AI S7-1200, analog Input SM 1231 TC, 8 AI
Analog value generation
for the inputs
3
thermocouples type J, K
• Also for the measurement of analog signals with a low level
(±80 mV) Accessories
■ Technical specifications
Article number 6ES7231-5QA30-0XB0 Article number 6ES7231-5QA30-0XB0
Signal Board SB 1231 TC, 1 AI Signal Board SB 1231 TC, 1 AI
General information Errors/accuracies
Product type designation SB 1231, AI 1x16 bit TC Temperature error 25 °C ±0.1%, to 55 °C ±0.2% total
Supply voltage (relative to input range), (+/-) measurement range
Rated value (DC) 24 V Repeat accuracy in steady state at 0.5 %
25 °C (relative to output range), (+/-)
Input current
Interference voltage suppression for
Current consumption, typ. 5 mA f = n x (f1 +/- 1 %),
from backplane bus 5 V DC, typ. 20 mA f1 = interference frequency
Analog inputs • Common mode interference, min. 120 dB
Number of analog inputs 1; Thermocouples Interrupts/diagnostics/
status information
permissible input voltage for current ±35 V
input (destruction limit), max. Alarms Yes
Technical unit for temperature Degrees Celsius/degrees Fahrenheit Diagnostics function Yes; Can be read out
measurement adjustable Alarms
Input ranges • Diagnostic alarm Yes
• Voltage Yes Diagnoses
• Current No • Wire-break Yes
• Thermocouple Yes; J, K, T, E, R & S, B, N, C, Diagnostics indication LED
TXK/XK(L);
voltage range: ±80 mV • for status of the inputs Yes
• Resistance thermometer No • for maintenance Yes
• Resistance No Standards, approvals, certificates
Input ranges (rated values), CE mark Yes
voltages CSA approval Yes
• -80 mV to +80 mV Yes UL approval Yes
Input ranges (rated values), cULus Yes
thermocouples FM approval Yes
• Type J Yes RCM (formerly C-TICK) Yes
• Type K Yes KC approval Yes
Thermocouple (TC) Marine approval Yes
Temperature compensation Ambient conditions
- parameterizable No Ambient temperature during
Analog outputs operation
Number of analog outputs 0 • min. -20 °C
Cable length • max. 60 °C
• shielded, max. 100 m; shielded, twisted pair Pollutant concentrations
Analog value generation • SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm;
for the inputs condensation RH < 60% condensation-free
Integration and conversion Connection method
time/resolution per channel required front connector Yes
• Resolution with overrange 15 bit; + sign Mechanics/material
(bit including sign), max.
Enclosure material (front)
• Integration time, parameterizable No
• Plastic Yes
• Interference voltage suppression 85 dB at 10 / 50 / 60 / 400 Hz
for interference frequency f1 in Hz Dimensions
Smoothing of measured values Width 38 mm
• parameterizable Yes Height 62 mm
Depth 21 mm
Weights
Weight, approx. 35 g
■ Overview
• For the convenient recording of temperatures with great • Most popular resistance temperature sensors can be used
accuracy • Can easily be retrofitted to existing installation
• 4 inputs
■ Technical specifications
Article number 6ES7231-5PD32-0XB0 6ES7231-5PF32-0XB0
S7-1200, analog Input SM 1231 RTD, 4 AI S7-1200, analog Input SM 1231 RTD, 8 AI
General information
Product type designation SM 1231, AI 4x16 bit RTD SM 1231, AI 8x16 bit RTD
Supply voltage
Rated value (DC) 24 V 24 V
Input current
Current consumption, typ. 40 mA 40 mA
from backplane bus 5 V DC, typ. 80 mA 80 mA
Analog inputs
Number of analog inputs 4; Resistance thermometer 8; Resistance thermometer
permissible input voltage for voltage ±35 V ±35 V
input (destruction limit), max.
Technical unit for temperature Degrees Celsius/degrees Fahrenheit Degrees Celsius/degrees Fahrenheit
measurement adjustable
Input ranges
• Voltage No No
• Current No No
• Thermocouple No No
• Resistance thermometer Yes; Resistance-type transmitter: Pt10, Pt50, Pt100, Pt200, Yes; Resistance-type transmitter: Pt10, Pt50, Pt100, Pt200,
Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10,
Cu50, Cu100, LG-Ni1000 Cu50, Cu100, LG-Ni1000
• Resistance Yes; 150 Ω, 300 Ω, 600 Ω Yes; 150 Ω, 300 Ω, 600 Ω
■ Technical specifications
Article number 6ES7231-5PD32-0XB0 6ES7231-5PF32-0XB0
S7-1200, analog Input SM 1231 RTD, 4 AI S7-1200, analog Input SM 1231 RTD, 8 AI
Input ranges (rated values),
resistance thermometer
• Cu 10
• Ni 100
Yes
Yes
Yes
Yes
3
• Ni 1000 Yes Yes
• LG-Ni 1000 Yes Yes
• Ni 120 Yes Yes
• Ni 200 Yes Yes
• Ni 500 Yes Yes
• Pt 100 Yes Yes
• Pt 1000 Yes Yes
• Pt 200 Yes Yes
• Pt 500 Yes Yes
Input ranges (rated values),
resistors
• 0 to 150 ohms Yes Yes
• 0 to 300 ohms Yes Yes
• 0 to 600 ohms Yes Yes
Thermocouple (TC)
Temperature compensation
- parameterizable No No
Analog value generation for the
inputs
Integration and conversion
time/resolution per channel
• Resolution with overrange 15 bit; + sign 15 bit; + sign
(bit including sign), max.
• Integration time, parameterizable No No
• Interference voltage suppression for 85 dB at 50 / 60 / 400 Hz 85 dB at 50 / 60 / 400 Hz
interference frequency f1 in Hz
Errors/accuracies
Temperature error (relative to input 25 °C ±0.1%, to 55 °C ±0.2% total measurement range 25 °C ±0.1%, to 55 °C ±0.2% total measurement range
range), (+/-)
Repeat accuracy in steady state at 0.05 % 0.05 %
25 °C (relative to output range), (+/-)
Interference voltage suppression for
f = n x (f1 +/- 1 %), f1 = interference
frequency
• Common mode interference, min. 120 dB 120 dB
Interrupts/diagnostics/
status information
Alarms Yes Yes
Diagnostics function Yes; Can be read out Yes; Can be read out
Alarms
• Diagnostic alarm Yes Yes
Diagnoses
• Monitoring the supply voltage Yes Yes
• Wire-break Yes Yes
Diagnostics indication LED
• for status of the inputs Yes Yes
• for maintenance Yes Yes
■ Technical specifications
Article number 6ES7231-5PD32-0XB0 6ES7231-5PF32-0XB0
S7-1200, analog Input SM 1231 RTD, 4 AI S7-1200, analog Input SM 1231 RTD, 8 AI
Standards, approvals, certificates
CE mark Yes Yes
3 CSA approval
UL approval
Yes
Yes
Yes
Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Pollutant concentrations
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm; S02: < 0.5 ppm; H2S: < 0.1 ppm;
condensation RH < 60% condensation-free RH < 60% condensation-free
Connection method
required front connector Yes Yes
Mechanics/material
Enclosure material (front)
• Plastic Yes Yes
Dimensions
Width 45 mm 70 mm
Height 100 mm 100 mm
Depth 75 mm 75 mm
Weights
Weight, approx. 220 g 220 g
■ Technical specifications
Article number 6ES7231-5PA30-0XB0 Article number 6ES7231-5PA30-0XB0
Signal Board SB 1231 RTD Signal Board SB 1231 RTD
General information Errors/accuracies
Product type designation SB 1231, AI 1x16 bit RTD Temperature error 25 °C ±0.1%, to 55 °C ±0.2% total
Supply voltage (relative to input range), (+/-) measurement range
Rated value (DC) 24 V Repeat accuracy in steady state at 0.05 %
25 °C (relative to output range), (+/-)
Input current
Interference voltage suppression for
Current consumption, typ. 5 mA f = n x (f1 +/- 1 %),
from backplane bus 5 V DC, typ. 20 mA f1 = interference frequency
Analog inputs • Common mode interference, min. 120 dB
Number of analog inputs 1; Resistance thermometer Interrupts/diagnostics/
status information
permissible input voltage for current ±35 V
input (destruction limit), max. Alarms Yes
Technical unit for temperature Degrees Celsius/degrees Fahrenheit Diagnostics function Yes; Can be read out
measurement adjustable Alarms
Input ranges • Diagnostic alarm Yes
• Voltage Yes Diagnoses
• Current No • Wire-break Yes
• Thermocouple No Diagnostics indication LED
• Resistance thermometer Yes; Platinum (Pt) • for status of the inputs Yes
• Resistance Yes; 150 Ω, 300 Ω, 600 Ω • for maintenance Yes
Input ranges (rated values), Standards, approvals, certificates
resistance thermometer
CE mark Yes
• Pt 100 Yes
CSA approval Yes
• Pt 1000 Yes
UL approval Yes
• Pt 200 Yes
cULus Yes
• Pt 500 Yes
FM approval Yes
Input ranges (rated values),
resistors RCM (formerly C-TICK) Yes
• 0 to 150 ohms Yes KC approval Yes
• 0 to 300 ohms Yes Marine approval Yes
• 0 to 600 ohms Yes Ambient conditions
Thermocouple (TC) Ambient temperature during
operation
Temperature compensation
• min. -20 °C
- parameterizable No
• max. 60 °C
Analog outputs
Pollutant concentrations
Number of analog outputs 0
• SO2 at RH < 60% without S02: < 0.5 ppm; H2S: < 0.1 ppm;
Cable length condensation RH < 60% condensation-free
• shielded, max. 100 m; shielded, twisted pair Connection method
Analog value generation required front connector Yes
for the inputs
Mechanics/material
Integration and conversion
time/resolution per channel Enclosure material (front)
• Resolution with overrange 15 bit; + sign • Plastic Yes
(bit including sign), max. Dimensions
• Integration time, parameterizable No Width 38 mm
• Interference voltage suppression 85 dB at 10 / 50 / 60 / 400 Hz Height 62 mm
for interference frequency f1 in Hz Depth 21 mm
Weights
Weight, approx. 35 g
3
networks (TN, TT) up to 480 V AC;
• Current measurement performed by 1 A and 5 A current current range: 1 A, 5 A;
transformers recording of voltage, current, phase
angles, power ratings, energy
• Can be used in TN and TT networks values, frequencies; with channel
• Data backup of measurement data in the event of a power diagnostics
failure Extension cable for two-tier 6ES7290-6AA30-0XA0
configuration
For connecting digital/analog signal
modules; length 2 m
Terminal block (spare part)
• For voltage input (top), 7-pin,
tin-coated, coded in middle
- Screw-type system 6ES7292-1AG40-0XA2
- Push-in system 6ES7292-2AG40-0XA2
For current input (bottom), 7-pin,
tin-coated
- Screw-type system 6ES7292-1AG30-0XA0
- Push-in system 6ES7292-2AG30-0XA0
Front flap set (spare part)
For modules with a width of 45 mm 6ES7291-1BA30-0XA0
■ Technical specifications
Article number 6ES7238-5XA32-0XB0 Article number 6ES7238-5XA32-0XB0
SM 1238 Energy Meter 480V AC SM 1238 Energy Meter 480V AC
General information Installation type/mounting
Product type designation SM 1238, AI energy meter 480 V AC Mounting position Horizontal, vertical
Product function Supply voltage
• Voltage measurement Yes Design of the power supply from CPU
- with voltage transformer Yes Type of supply voltage DC
• Current measurement Yes Input current
- without current transformer No Current consumption, max. 180 mA
- with current transformer Yes Analog inputs
• Energy measurement Yes Cycle time (all channels), typ. 50 ms; Time for consistent update of
• Frequency measurement Yes all measured and calculated values
(cyclic und acyclic data)
• Power measurement Yes
Interrupts/diagnostics/
• Active power measurement Yes status information
• Reactive power measurement Yes Alarms
• I&M data Yes; I&M 0 • Diagnostic alarm Yes
• Isochronous mode No • Limit value alarm Yes
Engineering with • Hardware interrupt No
• STEP 7 TIA Portal V13 SP1 Diagnostics indication LED
configurable/integrated from version
• Monitoring of the supply voltage Yes
Operating mode (PWR-LED)
• cyclic measurement Yes • Channel status display Yes; green LED
• acyclic measurement Yes • for channel diagnostics Yes; red Fn LED
• Acyclic measured value access Yes • for module diagnostics Yes; green/red DIAG LED
• Fixed measured value sets Yes
• Freely definable measured value sets No
■ Technical specifications
Article number 6ES7238-5XA32-0XB0 Article number 6ES7238-5XA32-0XB0
SM 1238 Energy Meter 480V AC SM 1238 Energy Meter 480V AC
Integrated Functions Accuracy class according to
Measuring functions IEC 61557-12
• Measuring procedure for voltage
measurement
TRMS - Measured variable apparent
power
0.5
3
• Measuring procedure for current TRMS - Measured variable active power 0.5
measurement - Measured variable power factor 0.5
• Type of measured value acquisition seamless - Measured variable active energy 0.5
• Curve shape of voltage Sinusoidal or distorted - Measured variable neutral current 0.5; calculated
• Buffering of measured variables Yes - Measured variable phase angle ±1 °; not covered by IEC 61557-12
• Parameter length 74 byte - Measured variable frequency 0.05
• Bandwidth of measured value 2 kHz; Harmonics: 39 / 50 Hz, Potential separation
acquisition 32 / 60 Hz Potential separation channels
Measuring range • between the channels and Yes; 3 700V AC (type test) CAT III
- Frequency measurement, min. 45 Hz backplane bus
- Frequency measurement, max. 65 Hz Standards, approvals, certificates
Measuring inputs for voltage CE mark Yes
- Measurable line voltage between 277 V CSA approval Yes
phase and neutral conductor UL approval Yes
- Measurable line voltage between 480 V cULus Yes
the line conductors
FM approval Yes
- Measurable line voltage between 0 V
phase and neutral conductor, min. RCM (formerly C-TICK) Yes
- Measurable line voltage between 293 V KC approval Yes
phase and neutral conductor, max. Marine approval Yes
- Measurable line voltage between 0V Dimensions
the line conductors, min.
Width 45 mm
- Measurable line voltage between 508 V
the line conductors, max. Height 100 mm
- Internal resistance line conductor 3.4 MΩ Depth 75 mm
and neutral conductor Weights
- Power consumption per phase 20 mW Weight, approx. 165 g
- Impulse voltage resistance 1 kV Data for selecting a current
1,2/50µs transformer
- Measurement category for voltage CAT II; CAT III in case of guaranteed • Burden power current transformer As a function of cable length and
measurement in accordance with protection level of 1.5 kV x/1A, min. cross section, see device manual
IEC 61010-2-030
• Burden power current transformer As a function of cable length and
Measuring inputs for current x/5A, min. cross section, see device manual
- measurable relative current (AC), 1 %; Relative to the secondary rated
min. current 5 A
- measurable relative current (AC), 100 %; Relative to the secondary
max. rated current 5 A
- Continuous current with AC, 5A
maximum permissible
- Apparent power consumption per 0.6 V·A
phase for measuring range 5 A
- Rated value short-time withstand 100 A
current restricted to 1 s
- Input resistance measuring range 25 mΩ; At the terminal
0 to 5 A
- Surge strength 10 A; for 1 minute
- Zero point suppression Parameterizable: 2 ... 250 mA,
default 50 mA
■ Technical specifications
Article number 6AG1231-4HD32-4XB0 6AG1231-4HF32-4XB0 6AG1231-5ND32-4XB0
Based on 6ES7231-4HD32-0XB0 6ES7231-4HF32-0XB0 6ES7231-5ND32-0XB0
SIPLUS S7-1200 SM 1231 4AI 13Bit SIPLUS S7-1200 SM 1231 8AI 13Bit SIPLUS S7-1200 SM 1231 4AI 16Bit
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin -20 °C; = Tmin -20 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ 0 °C start-up @ 0 °C start-up @ 0 °C
• max. 60 °C; = Tmax 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
■ Technical specifications
Article number 6AG1231-4HD32-4XB0 6AG1231-4HF32-4XB0 6AG1231-5ND32-4XB0
Based on 6ES7231-4HD32-0XB0 6ES7231-4HF32-0XB0 6ES7231-5ND32-0XB0
SIPLUS S7-1200 SM 1231 4AI 13Bit SIPLUS S7-1200 SM 1231 8AI 13Bit SIPLUS S7-1200 SM 1231 4AI 16Bit
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
3
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1232-4HB32-4XB0 6AG1232-4HD32-2XB0 6AG1232-4HD32-4XB0
Based on 6ES7232-4HB32-0XB0 6ES7232-4HD32-0XB0 6ES7232-4HD32-0XB0
SIPLUS S7-1200 SM 1232 2AQ 13Bit SIPLUS S7-1200 SM 1232 4AQ 14Bit SIPLUS S7-1200 SM 1232 4AQ 14Bit
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin -40 °C; = Tmin -20 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ 0 °C start-up @ -25 °C start-up @ 0 °C
• max. 60 °C; = Tmax 70 °C; = Tmax 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
■ Technical specifications
Article number 6AG1232-4HB32-4XB0 6AG1232-4HD32-2XB0 6AG1232-4HD32-4XB0
Based on 6ES7232-4HB32-0XB0 6ES7232-4HD32-0XB0 6ES7232-4HD32-0XB0
SIPLUS S7-1200 SM 1232 2AQ 13Bit SIPLUS S7-1200 SM 1232 4AQ 14Bit SIPLUS S7-1200 SM 1232 4AQ 14Bit
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
3
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request (excluding fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1232-4HA30-4XB0 6AG1232-4HA30-5XB0
Based on 6ES7232-4HA30-0XB0 6ES7232-4HA30-0XB0
SIPLUS S7-1200 SB 1232 1AQ SIPLUS S7-1200 SB 1232 1AQ
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
• max. 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under condensation conditions) (no commissioning under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
■ Technical specifications
Article number 6AG1232-4HA30-4XB0 6AG1232-4HA30-5XB0
Based on 6ES7232-4HA30-0XB0 6ES7232-4HA30-0XB0
SIPLUS S7-1200 SB 1232 1AQ SIPLUS S7-1200 SB 1232 1AQ
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
3
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1234-4HE32-2XB0 6AG1234-4HE32-4XB0
Based on 6ES7234-4HE32-0XB0 6ES7234-4HE32-0XB0
SIPLUS S7-1200 SM 1234 4AI/2AQ SIPLUS S7-1200 SM 1234 4AI/2AQ 13Bit
Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
• max. 70 °C; = Tmax; Tmax > +60 °C number of simultaneously 60 °C; = Tmax
used outputs 1, inputs 2 (no adjacent points) for horizontal
mounting position
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
■ Technical specifications
Article number 6AG1234-4HE32-2XB0 6AG1234-4HE32-4XB0
Based on 6ES7234-4HE32-0XB0 6ES7234-4HE32-0XB0
SIPLUS S7-1200 SM 1234 4AI/2AQ SIPLUS S7-1200 SM 1234 4AI/2AQ 13Bit
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
3
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1231-5QF32-4XB0 6AG1231-5QD32-4XB0
Based on 6ES7231-5QF32-0XB0 6ES7231-5QD32-0XB0
SIPLUS S7-1200 SM 1231 8AI TC 16Bit SIPLUS S7-1200 SM 1231 4AI TC 16Bit
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
• max. 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
■ Technical specifications
Article number 6AG1231-5QF32-4XB0 6AG1231-5QD32-4XB0
Based on 6ES7231-5QF32-0XB0 6ES7231-5QD32-0XB0
SIPLUS S7-1200 SM 1231 8AI TC 16Bit SIPLUS S7-1200 SM 1231 4AI TC 16Bit
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
3
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1231-5PD32-4XB0 6AG1231-5PD32-2XB0 6AG1231-5PF32-4XB0 6AG1231-5PF32-2XB0
Based on 6ES7231-5PD32-0XB0 6ES7231-5PD32-0XB0 6ES7231-5PF32-0XB0 6ES7231-5PF32-0XB0
SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231
4AI RTD 16Bit 4AI RTD 16Bit 8AI RTD 16Bit 8AI RTD 16Bit
Ambient conditions
Ambient temperature during
operation
• min. -20 °C; = Tmin -40 °C; = Tmin -20 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ 0 °C start-up @ -25 °C start-up @ 0 °C start-up @ -25 °C
• max. 60 °C; = Tmax 70 °C; = Tmax 60 °C; = Tmax 70 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
■ Technical specifications
Article number 6AG1231-5PD32-4XB0 6AG1231-5PD32-2XB0 6AG1231-5PF32-4XB0 6AG1231-5PF32-2XB0
Based on 6ES7231-5PD32-0XB0 6ES7231-5PD32-0XB0 6ES7231-5PF32-0XB0 6ES7231-5PF32-0XB0
SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231 SIPLUS S7-1200 SM 1231
4AI RTD 16Bit 4AI RTD 16Bit 8AI RTD 16Bit 8AI RTD 16Bit
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
3
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 permissible); level LC3 permissible); level LC3 permissible); level LC3
(salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3 (salt spray) and level LB3
(oil) (oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1231-5PA30-5XB0 Article number 6AG1231-5PA30-5XB0
Based on 6ES7231-5PA30-0XB0 Based on 6ES7231-5PA30-0XB0
SIPLUS S7-1200 SB 1231 1AI RTD SIPLUS S7-1200 SB 1231 1AI RTD
Ambient conditions Use on ships/at sea
Ambient temperature during - to biologically active substances Yes; Class 6B2 mold and fungal
operation according to EN 60721-3-6 spores (excluding fauna); Class 6B3
• min. -40 °C; = Tmin on request
(incl. condensation/frost); - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt
start-up @ -25 °C according to EN 60721-3-6 spray acc. to EN 60068-2-52
• max. 60 °C; = Tmax (severity degree 3); *
Altitude during operation - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
relating to sea level according to EN 60721-3-6
• Installation altitude above sea level, 5 000 m Usage in industrial process
max. technology
• Ambient air temperature-barometric Tmin ... Tmax at - Against chemically active Yes; Class 3 (excluding
pressure-altitude 1 140 hPa ... 795 hPa substances acc. to EN 60654-4 trichlorethylene)
(-1 000 m ... +2 000 m) // - Environmental conditions for Yes; Level GX group A/B
Tmin ... (Tmax - 10 K) at process, measuring and control (excluding trichlorethylene; harmful
795 hPa ... 658 hPa systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits
(+2 000 m ... +3 500 m) // of EN 60721-3-3 class 3C4
Tmin ... (Tmax -20 K) at permissible); level LC3 (salt spray)
658 hPa ... 540 hPa and level LB3 (oil)
(+3 500 m ... +5 000 m) Remark
Relative humidity - Note regarding classification of * The supplied plug covers must
• With condensation, tested in 100 %; RH incl. condensation / frost environmental conditions acc. to remain in place over the unused
accordance with IEC 60068-2-38, (no commissioning in bedewed EN 60721, EN 60654-4 and interfaces during operation!
max. state), horizontal installation ANSI/ISA-71.04
Resistance Conformal coating
Coolants and lubricants • Coatings for printed circuit board Yes; Class 2 for high reliability
- Resistant to commercially Yes; Incl. diesel and oil droplets in assemblies acc. to EN 61086
available coolants and lubricants the air • Protection against fouling acc. to Yes; Type 1 protection
Use in stationary industrial systems EN 60664-3
- to biologically active substances Yes; Class 3B2 mold, fungus and dry • Military testing according to Yes; Discoloration of coating
according to EN 60721-3-3 rot spores (with the exception of MIL-I-46058C, Amendment 7 possible during service life
fauna); Class 3B3 on request • Qualification and Performance of Yes; Conformal coating, Class A
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Electrical Insulating Compound for
according to EN 60721-3-3 spray acc. to EN 60068-2-52 Printed Board Assemblies
(severity degree 3); * according to IPC-CC-830A
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
3
Specification V1.1
Terminal block (spare part)
• 7-pin, tin-coated; 4 units
- Screw-type system 6ES7292-1AG30-0XA0
- Push-in system 6ES7292-2AG30-0XA0
■ Technical specifications
Article number 6ES7278-4BD32-0XB0 Article number 6ES7278-4BD32-0XB0
S7-1200, SM1278, S7-1200, SM1278,
4 X IO-Link Master 4 X IO-Link Master
General information Ambient conditions
Product type designation SM 1278 4xIO-Link master Ambient temperature
Supply voltage during operation
Rated value (DC) 24 V • min. -20 °C
Interrupts/diagnostics/ • max. 60 °C
status information Connection method
Diagnostics function Yes required front connector Yes
Standards, approvals, certificates Dimensions
CE mark Yes Width 45 mm
CSA approval Yes Height 100 mm
UL approval Yes Depth 75 mm
cULus Yes Weights
FM approval Yes Weight, approx. 150 g
RCM (formerly C-TICK) Yes
KC approval Yes
Marine approval Yes
6AG1278-4BD32-2XB0
number of simultaneously
controllable inputs and outputs
max. 50%
■ Technical specifications
Article number 6AG1278-4BD32-2XB0 6AG1278-4BD32-4XB0
Based on 6ES7278-4BD32-0XB0 6ES7278-4BD32-0XB0
SIPLUS S7-1200 SM 1278 IO-Link Master SIPLUS S7-1200 SM 1278 IO-Link Master
Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C -20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
• max. 70 °C; = Tmax 60 °C; = Tmax
• At cold restart, min. -25 °C 0 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Technical specifications
Article number 6AG1278-4BD32-2XB0 6AG1278-4BD32-4XB0
Based on 6ES7278-4BD32-0XB0 6ES7278-4BD32-0XB0
SIPLUS S7-1200 SM 1278 IO-Link Master SIPLUS S7-1200 SM 1278 IO-Link Master
Use on ships/at sea
- to biologically active substances
according to EN 60721-3-6
Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
Class 6B3 on request Class 6B3 on request
3
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
environmental conditions acc. to unused interfaces during operation! unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
3
components based on
characteristic values and
frequency-selective analysis
functions.
Accessories
SIPLUS CMS1200, 6AT8007-1AA20-0AA0
SM 1281 shield clamp set
For EMC-compliant connection of
signal and encoder cables to
SIPLUS CMS1200 SM 1281
Condition Monitoring.
SIPLUS VIB-SENSOR S01 6AT8002-4AB00
Piezoelectric sensor for connection
to SIPLUS CMS1200 SM 1281
Condition Monitoring.
■ Technical specifications
Article number 6AT8007-1AA10-0AA0 Article number 6AT8007-1AA10-0AA0
SM1281_Condition_Monitoring SM1281_Condition_Monitoring
General information Power loss
Product type designation SM1281 Power loss, typ. 4.8 W
Product description S7-1200 module for the monitoring Memory
of vibrations on mechanical Total memory capacity 1 Gbyte
components based on parameters
and frequency-selective analysis Hardware configuration
functions Design of hardware configuration Modular, up to 7 modules per CPU
Installation type/mounting Speed input
Mounting type Rail or wall mounting Number of speed inputs 1
Mounting position Horizontal, vertical Input voltage
Recommended mounting position Horizontal • 24 V DC digital Yes
Supply voltage Sensor input
Type of supply voltage DC Number of IEPE sensor inputs 4
Rated value (DC) 24 V Sampling frequency, max. 46 875 Hz
permissible range, lower limit (DC) 20.4 V Interfaces
permissible range, upper limit (DC) 28.8 V Type of data transmission Export of raw data as WAV file for
Input current further analysis (e.g. using
CMS X-Tools) can be downloaded
Current consumption, typ. 200 mA via browser/FTP, online data transfer
Current consumption, max. 250 mA to CMS X-Tools
from backplane bus 5 V DC, typ. 80 mA Ethernet interface Yes
from backplane bus 5 V DC, max. 85 mA Protocols
Bus communication Yes
Web server
• HTTP Yes
■ Technical specifications
Article number 6AT8007-1AA10-0AA0 Article number 6AT8007-1AA10-0AA0
SM1281_Condition_Monitoring SM1281_Condition_Monitoring
Interrupts/diagnostics/ Standards, approvals, certificates
status information Certificate of suitability CE
Alarms
• Diagnostic alarm Yes
Ambient conditions
Free fall
3
Diagnostics indication LED • Fall height, max. 0.3 m; five times,
• for status of the inputs Yes in product package
• for maintenance Yes Software
• Status indicator digital input (green) No Browser software required Web browser Mozilla Firefox (ESR31)
Integrated Functions or Microsoft Internet Explorer (10/11)
Monitoring functions Connection method
• Monitoring of the sensor inputs Yes; Cable break and short-circuit required front connector Yes
• Vibration characteristic monitoring Yes Design of electrical connection Screw connection
via RMS value of the vibration speed Mechanics/material
• Vibration characteristic monitoring Yes Material of housing Plastic: polycarbonate,
via RMS value of the vibration abbreviation: PC- GF 10 FR
acceleration Dimensions
• Vibration characteristic monitoring Yes Width 70 mm
via diagnostic characteristic value
Height 112 mm
• Frequency-selective monitoring via Yes
vibration speed spectrum Depth 75 mm
• Frequency-selective monitoring via Yes Weights
vibration acceleration spectrum Weight, approx. 260 g
• Frequency-selective monitoring via Yes
envelope curve analysis
Measuring functions
• Physical measuring principle Vibration acceleration
Measuring range
- Measurement range vibration 0.1 Hz
frequency, min.
- Measurement range vibration 10 000 Hz
frequency, max.
■ Technical specifications
Article number 6ES7274-1XF30-0XA0 6ES7274-1XH30-0XA0
S7-1200 Simulator Module SIM1274, 8 Inp S7-1200 Simulator Module SIM1274, 14 Inp
General information
Product type designation SIM 1274, 8DI SIM 1274, 14 DI
Supply voltage
Rated value (DC) 24 V 24 V
Digital inputs
Number of digital inputs 8 14
Digital outputs
Number of digital outputs 0 0
Dimensions
Width 43 mm 67 mm
Height 35 mm 35 mm
Depth 23 mm 23 mm
3
CPU in FW version 3.0 or higher;
battery (CR 1025) is not included
Terminal block (spare part)
For signal board
with 6 screws, gold-plated; 4 units 6ES7292-1BF30-0XA0
■ Technical specifications
Article number 6ES7297-0AX30-0XA0 Article number 6ES7297-0AX30-0XA0
Battery Board BB 1297 f. CPU 12xx Battery Board BB 1297 f. CPU 12xx
General information Ambient conditions
Product type designation BB 1297 Free fall
Interrupts/diagnostics/ • Fall height, max. 0.3 m; five times,
status information in product package
Alarms Yes Ambient temperature during
Diagnostics function Yes operation
Diagnostics indication LED • min. -20 °C
• for maintenance Yes; The maintenance LED (MAINT) • max. 60 °C
of the PLC signals that the battery Ambient temperature during
needs to be replaced. storage/transportation
Standards, approvals, certificates • min. -40 °C
CE mark Yes • max. 70 °C
CSA approval Yes Air pressure acc. to IEC 60068-2-13
FM approval Yes • Operation, min. 795 hPa
RCM (formerly C-TICK) Yes • Operation, max. 1 080 hPa
Marine approval Yes • Storage/transport, min. 660 hPa
• Storage/transport, max. 1 080 hPa
Relative humidity
• Operation at 25 ? without 95 %
condensation, max.
Mechanics/material
Enclosure material (front)
• Plastic Yes
Dimensions
Width 38 mm
Height 62 mm
Depth 21 mm
Weights
Weight, approx. 40 g
■ Overview
SIWAREX WP231 is a versatile, legal for trade weighing module
for all simple weighing and force measuring tasks. The compact
module is easy to install in the SIMATIC S7-1200 automation
system. It can also be operated without a SIMATIC CPU.
■ Technical specifications
SIWAREX WP231 SIWAREX WP231
Integration in automation systems Load cells Full-bridge strain gauges in 4-wire or
6-wire system
S7-1200 SIMATIC S7-1200 system bus
Load cell powering
3 Operator panel and/or automation
systems from other vendors
Via Ethernet (Modbus TCP/IP) or
RS 485 (Modbus RTU) Supply voltage
(regulated via feedback)
4.85 V DC
Communication interfaces • SIMATIC S7-1200 backplane bus
• RS 485 (Modbus RTU, Permissible load resistance
Siebert remote display) • RLmin > 40 Ω
• Ethernet (SIWATOOL V7, • RLmax < 4 100 Ω
Modbus TCP/IP)
• Analog output 0/4 - 20 mA With SIWAREX IS Ex interface
• 4 × digital outputs 24 V DC, • RLmin > 50 Ω
floating, short-circuit proof
• RLmax < 4 100 Ω
• 4 × digital inputs 24 V DC, floating
Load cell characteristic 1 … 4 mV/V
Commissioning options • Using SIWATOOL V7
• Using function block in Permissible range of the -21.3 ... +21.3 mV
SIMATIC S7-1200 CPU / measurement signal
Touch Panel (with 4 mV/V sensors)
• Using Modbus TCP/IP
• Using Modbus RTU Max. distance of load cells 500 m (229.66 ft)
■ Overview
SIWAREX WP241 is a flexible weighing module for belt scales.
The compact module is easy to install in the SIMATIC S7-1200
automation system. It can also be operated as a stand-alone
module, i.e. without a SIMATIC CPU.
■ Technical specifications
SIWAREX WP241 SIWAREX WP241
Integration in automation systems Load cells Full-bridge strain gauges in 4-wire or
6-wire system
S7-1200 SIMATIC S7-1200 system bus
Load cell powering
Operator panel and/or automation Via Ethernet (Modbus TCP/IP) or
systems from other vendors RS 485 (Modbus RTU) Supply voltage 4.85 V DC
(regulated via feedback)
Communication interfaces • SIMATIC S7-1200 backplane bus
• RS 485 (Modbus RTU) Permissible load resistance
• Ethernet (SIWATOOL V7, • RLmin > 40 Ω
Modbus TCP/IP) • RLmax < 4 100 Ω
• Analog output 0/4 - 20 mA
• 4 × digital outputs, 24 V DC, With SIWAREX IS Ex interface
floating, short-circuit proof • RLmin > 50 Ω
• 4 × digital inputs 24 V DC, floating
• RLmax < 4 100 Ω
Commissioning options • Using SIWATOOL V7
Load cell characteristic 1 … 4 mV/V
• Using function block in
SIMATIC S7-1200 CPU / Touch Permissible measurement signal -21.3 ... +21.3 mV
Panel range
• Using Modbus TCP/IP
• Using Modbus RTU Max. distance of load cells 500 m (229.66 ft)
■ Overview
SIWAREX WP251 is a flexible weighing module for dosing
and filling processes. The compact module can be installed
seamlessly in the SIMATIC S7-1200 automation system. It can
also be used without a SIMATIC CPU in stand-alone mode.
Accessories Commissioning
SIWAREX JB junction box, 7MH5001-0AA20 Commissioning charge for one 9LA1110-8SN50-0AA0
aluminum housing static scale with SIWAREX
module
For connecting up to 4 load cells in
3 parallel, and for connecting
multiple junction boxes.
(Flat charge for travel and setup
must be ordered separately)
SIWAREX JB junction box, 7MH5001-0AA00 Scope:
stainless steel housing • Recording of data
• Checking of mechanical
For connecting up to 4 load cells in installation of the scale
parallel. • Checking of electrical wiring and
SIWAREX JB junction box, 7MH5001-0AA01 function
stainless steel housing (ATEX) • Static adjustment of the scale
Requirements:
For parallel connection of up to
• Mechanical design functional
4 load cells (for zone allocation,
• Modules electrically wired and
see manual or type-examination
tested
certificate).
• Calibration weights available
SIWAREX IS Ex interface • Free access to scale
For intrinsically safe connection of Flat charge for travel and setup 9LA1110-8RA10-0AA0
load cells. With ATEX approval in Germany
(not UL/FM). Suitable for SIWAREX
electronic weighing systems.
Compatibility of load cells must be
checked separately.
• Short-circuit current 7MH4710-5BA
< 199 mA DC
• Short-circuit current 7MH4710-5CA
< 137 mA DC
Cable (optional)
Cable Li2Y 1 × 2 × 0.75 ST +
2 × (2 × 0.34 ST) – CY
For connecting SIWAREX
electronic weighing systems to
junction box (JB), extension box
(EB) and Ex interface or between
two EBs. For permanent
installation. Occasional bending is
possible.
External diameter: approx.
10.8 mm (0.43 inch)
Permissible ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Sold by the meter.
• Sheath color: orange 7MH4702-8AG
• For hazardous atmospheres. 7MH4702-8AF
Sheath color: blue.
Ground terminal for connecting 6ES5728-8MA11
the load cell cable shield to the
grounded DIN rail
■ Technical specifications
SIWAREX WP251 SIWAREX WP251
Weighing modes • Non automatic weighing instrument Number of measurements/second 100 or 120 (selectable)
(NAWI) (filling + removal)
(legal-for-trade in accordance Filter • Low-pass filter 0.1 ... 50 Hz
• Average value filter
3
with OIML R76)
• Catchweighing instrument (CWI) Load cells Strain gauges in 4-wire or 6-wire
(filling + removal) (legal-for-trade in system
accordance with OIML R51) Load cell powering
• Gravimetric filling instrument (GFI)
(legal-for-trade in accordance with Supply voltage 4.85 V DC
OIML R61) (regulated via feedback)
• Discontinuous totalizing automatic Permissible load resistance
weighing instrument (DTI) - • RLmin > 40 Ω
(legal-for-trade in accordance • RLmax < 4 100 Ω
with OIML R107)
With SIWAREX IS Ex interface
Integration in automation systems
• RLmin > 50 Ω
S7-1200 SIMATIC S7-1200 system bus • RLmax < 4 100 Ω
Operator panel and/or automation Via Ethernet (Modbus TCP/IP) or Load cell characteristic 1 … 4 mV/V
systems from other vendors RS 485 (Modbus RTU)
Permissible range of the -21.3 ... +21.3 mV
Ports • 1 × SIMATIC S7-1200 system bus measurement signal
• 1 × Ethernet (SIWATOOL and (with 4 mV/V sensors)
Modbus TCP/IP)
• 1 x RS 485 (Modbus RTU or remote Max. distance of load cells 500 m (229.66 ft)
display) Connection to load cells in Ex zone 1 Optionally via SIWAREX IS Ex interface
• 1 x analog output (0/4 - 20 mA)
• 4 × digital inputs (24 V DC, floating) Certificates • ATEX Zone 2
• 4 × digital outputs (24 V DC, • UL
floating, short-circuit proof) • KCC
• EAC
Functions • 3 limits • RCM
• Tare
• Tare specification Calibration approvals • EU type-examination certificate
• Zeroing 2014/31/EU (NAWI) according to
• Zero adjustment OIML R76
• Statistics • EU type-examination certificate
• Automatic correction of the shut-off 2014/32/EU (MID) according to
points OIML R61 and OIML R51
• Internal protocol memory for • EU type-examination certificates
550 000 entries 2014/32/EU (MID) according to
• Trace function for signal analysis OIML R107
• Internal restore point
• Stand-alone mode or Auxiliary power supply
SIMATIC S7-1200 integrated Rated voltage 24 V DC
Parameter assignment • Full access using function block in Max. power consumption 200 mA
SIMATIC S7-1200
• Full access using Modbus TCP/IP Max. power consumption 3 mA
• Full access using Modbus RTU SIMATIC Bus
Remote display IP degree of protection to IP20
DIN EN 60529; IEC 60529
Connection Via RS 485
Climatic requirements
Scale adjustment PC software SIWATOOL (Ethernet),
S7-1200 function block and touch Tmin(IND) ... Tmax(IND)
panel or directly connected operator (operating temperature)
panel (Modbus) • Vertical installation -10 ... +40 °C (14 ... 104 °F)
• Horizontal installation -10 ... +55 °C (14 ... 131 °F)
Measuring accuracy
EMC requirements According to EN 45501
Error limit according to DIN 1319-1 of 0.05%
full-scale value at 20 °C ± 10 K Dimensions 70 × 75 × 100 mm
(68 °F ± 10 K) (2.76 × 2.95 × 3.94 inch)
Internal resolution Up to ± 4 million parts
■ Technical specifications
Article number 6ES7241-1CH32-0XB0 6ES7241-1AH32-0XB0
Communications Module cm 1241, RS422/485 Communications Module cm 1241, RS232
General information
Product type designation CM 1241 RS 422 / 485 CM 1241 RS 232
Supply voltage
Rated value (DC) 24 V 24 V
Input current
Current consumption, max. 220 mA; From backplane bus 5 V DC 200 mA; From backplane bus 5 V DC
Interfaces
Interfaces/bus type RS 232C (V.24)
Number of interfaces 1 1
Point-to-point connection
• Cable length, max. 1 000 m 10 m
Integrated protocol driver
- Freeport Yes Yes
- ASCII Yes; Available as library function Yes; Available as library function
- Modbus RTU master Yes Yes
- MODBUS RTU slave Yes Yes
- USS Yes; Available as library function
■ Technical specifications
Article number 6ES7241-1CH32-0XB0 6ES7241-1AH32-0XB0
Communications Module cm 1241, RS422/485 Communications Module cm 1241, RS232
Protocols
Integrated protocols
Freeport
- Telegram length, max. 1 kbyte 1 kbyte
3
- Parity No parity (standard); even, uneven, mark No parity (standard); even, uneven, mark
(parity bit always 1); space (parity bit always 0) (parity bit always 1); space (parity bit always 0)
3964 (R)
- Telegram length, max. 1 kbyte 1 kbyte
- Parity No parity (standard); even, uneven, mark No parity (standard); even, uneven, mark
(parity bit always 1); space (parity bit always 0) (parity bit always 1); space (parity bit always 0)
Modbus RTU master
- Address area 1 through 49 999 (Standard Modbus addressing) 1 through 49 999 (Standard Modbus addressing)
- Number of slaves, max. 247; slave numbers 1 through 247, per MODBUS network 247; slave numbers 1 through 247, per MODBUS network
segment maximum 32 devices, additional repeaters segment maximum 32 devices, additional repeaters
needed to expand the network to maximum configuration needed to expand the network to maximum configuration
MODBUS RTU slave
- Address area 1 through 49 999 (Standard Modbus addressing) 1 through 49 999 (Standard Modbus addressing)
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes
Diagnostics indication LED
• for status of the outputs Yes Yes
Standards, approvals, certificates
CE mark Yes Yes
CSA approval Yes Yes
UL approval Yes Yes
cULus Yes Yes
FM approval Yes Yes
RCM (formerly C-TICK) Yes Yes
KC approval Yes Yes
Marine approval Yes Yes
Ambient conditions
Ambient temperature during
operation
• min. -20 °C -20 °C
• max. 60 °C 60 °C
Dimensions
Width 30 mm 30 mm
Height 100 mm 100 mm
Depth 75 mm 75 mm
Weights
Weight, approx. 155 g 150 g
■ Technical specifications
Article number 6ES7241-1CH30-1XB0 Article number 6ES7241-1CH30-1XB0
Communication Board CB 1241, Communication Board CB 1241,
RS485 RS485
General information Interrupts/diagnostics/
Product type designation CB 1241 RS 485 status information
Input current Diagnostics function Yes
from backplane bus 5 V DC, typ. 50 mA Standards, approvals, certificates
Interfaces CE mark Yes
Point-to-point connection CSA approval Yes
• Cable length, max. 1 000 m UL approval Yes
Integrated protocol driver cULus Yes
- Freeport Yes FM approval Yes
- ASCII Yes; Available as library function RCM (formerly C-TICK) Yes
- Modbus RTU master Yes KC approval Yes
- MODBUS RTU slave Yes Marine approval Yes
- USS Yes; Available as library function Ambient conditions
Protocols Ambient temperature
during operation
Integrated protocols
• min. -20 °C
Freeport
• max. 60 °C
- Telegram length, max. 1 kbyte
Dimensions
- Parity No parity (standard); even,
uneven, mark (parity bit always 1); Width 38 mm
space (parity bit always 0) Height 62 mm
3964 (R) Depth 21 mm
- Telegram length, max. 1 kbyte Weights
- Parity No parity (standard); even, Weight, approx. 40 g
uneven, mark (parity bit always 1);
space (parity bit always 0)
Modbus RTU master
- Address area 1 through 49 999
(Standard Modbus addressing)
- Number of slaves, max. 247; slave numbers 1 through 247,
per MODBUS network segment
maximum 32 devices, additional
repeaters needed to expand the
network to maximum configuration
MODBUS RTU slave
- Address area 1 through 49 999
(Standard Modbus addressing)
CM 1242-5 communications
module
Communications module for 6GK7242-5DX30-0XE0
electrical connection of
3
SIMATIC S7-1200 to PROFIBUS
as a DP slave module
Accessories
PROFIBUS FastConnect
connection plug RS485
With 90° cable outlet;
insulation displacement technology,
max. transmission rate 12 Mbps
• Without programming device 6ES7972-0BA52-0XA0
• With programming device 6ES7972-0BB52-0XA0
PROFIBUS FC Standard Cable
2-core bus cable, shielded, 6XV1830-0EH10
special design for fast mounting,
sold by the meter;
delivery unit: max. 1000 m,
DP-M DP-S FMS PG/OP S7 minimum order quantity 20 m,
sold by the meter
G_IK10_XX_10322
PROFIBUS FastConnect
Stripping Tool
Stripping tool for fast stripping of 6GK1905-6AA00
the PROFIBUS FastConnect bus
The CM 1242-5 communications module is used to connect cable
a SIMATIC S7-1200 to PROFIBUS as a DP slave and has
PROFIBUS bus terminal 12M
the following characteristics:
• PROFIBUS DPV1 slave in accordance with IEC 61158 Bus terminal for connection of 6GK1500-0AA10
PROFIBUS nodes at up to 12 Mbps
• Module replacement without PG supported with connecting cable
• Power is supplied via the backplane bus so that no extra
cabling is required
• Support of all standard baud rates from 9.6 kbps to 12 Mbps
• Compact industry-standard enclosure in S7-1200 design for
mounting on a DIN rail
• Fast commissioning thanks to easy configuration using
STEP 7 without additional programming overhead
The CM 1242-5 is intended for use in factory automation.
Low-cost PROFIBUS-based automation solutions can be
created on the basis of the SIMATIC S7-1200 for optimal
production.
■ Technical specifications
Article number 6GK7242-5DX30-0XE0 Article number 6GK7242-5DX30-0XE0
product type designation CM 1242-5 product type designation CM 1242-5
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-1200 single
3 • at the 1st interface acc. to
PROFIBUS
9.6 kbit/s ... 12 Mbit/s
width
width
30 mm
interfaces height 100 mm
number of interfaces acc. to Industrial 0 depth 75 mm
Ethernet net weight 0.115 kg
number of electrical connections fastening method
• at the 1st interface acc. to 1 • 35 mm top hat DIN rail mounting Yes
PROFIBUS
• S7-300 rail mounting No
• for power supply 0
• wall mounting Yes
type of electrical connection
product features, product functions,
• at the 1st interface acc. to 9-pin Sub-D socket (RS485) product components general
PROFIBUS
number of units
supply voltage, current
consumption, power loss • per CPU maximum 3
type of voltage of the supply voltage DC performance data PROFIBUS DP
supply voltage 1 from backplane bus 5 V service as DP slave
consumed current • DPV0 Yes
• from backplane bus at DC 0.15 A • DPV1 Yes
at 5 V typical data volume
power loss [W] 0.75 W • of the address range of the inputs as 240 byte
ambient conditions DP slave total
ambient temperature • of the address range of the outputs 240 byte
as DP slave total
• for vertical installation during 0 ... 45 °C
operation performance data telecontrol
• for horizontally arranged busbars 0 ... 55 °C protocol is supported
during operation • TCP/IP No
• during storage -40 ... +70 °C product functions management,
• during transport -40 ... +70 °C configuration, engineering
relative humidity configuration software
• at 25 °C without condensation 95 % • required STEP 7 Basic/Professional
during operation maximum
protection class IP IP20
■ More information
More information
Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/15750/man
■ Overview ■ Application
The AS-Interface data decoupling module is designed for
AS-Interface networks with 30 V or 24 V supply (AS-i Power24V).
Operation of an AS-i network with the data decoupling module
and a 30 V standard power supply unit is technically equivalent
to the use of an AS-Interface power supply unit and offers the
service-proven features of AS-Interface for all applications. 3
AS-i Power24V uses a 24 V power supply unit in conjunction with
a data decoupling module and is particularly suitable for
• Compact machines using AS-Interface input/output modules
• Applications in the control cabinet for AS-Interface integration
of SIRIUS 3RT2 contactors using 3RA27 function modules
Note:
The power supply units must comply with the standard ES1
(IEC 62368-1) or PELV (Protective Extra Low Voltage) or SELV
(Safety Extra Low Voltage), have a residual ripple of < 250 mVss,
and in the event of a fault must limit the output voltage to
a maximum of 40 V.
With the aid of the DCM 1271 data decoupling module, Recommended
the AS-Interface network can also be supplied with 24 V DC or
30 V DC from a standard power supply unit and the transmission • SITOP-power supplies, see
of data and power can be implemented on one cable. https://mall.industry.siemens.com/mall/en/WW/Catalog/
Products/10244081?tree=CatalogTree or
The DCM 1271 data decoupling module has the same type of https://support.industry.siemens.com/cs/ww/en/view/
enclosure as an S7-1200 module and can therefore be perfectly 109745655
combined with the AS-i Master CM 1243-2.
• PSN130S 30 V power supply units, see
The DCM 1271 data decoupling module has no connection to https://mall.industry.siemens.com/mall/en/WW/Catalog/
the backplane bus of the SIMATIC S7-1200 and is therefore not Products/10174512?tree=CatalogTree.
counted as a communications module for the calculation of the
maximum configuration. Note on AS-i Power24V:
The length of an AS-i Power24V network is restricted to 50 m
Features of the DCM 1271 data decoupling module in order to limit the voltage drop along the cable.
• Design: S7-1200, 30 mm wide, degree of protection IP20
AS-i Masters, AS-i slaves and the sensors and actuators
• Detachable terminals (included in delivery) supplied through the AS-i cable must be designed for
• Single data decoupling the reduced voltage. Sensors and actuators for the standard
• Supply of several AS-i networks with a single power supply unit voltage range of 10 to 30 V can be supplied with sufficient
voltage.
• Operation with 24 V DC or 30 V DC, grounded or
non-grounded Please also observe the requirements specified under
• Current limitation at 4 A "AS-i Power24V" for the operation of a AS-i Power24V network,
see
• Integrated ground-fault detection https://mall.industry.siemens.com/mall/en/WW/Catalog/
• Diagnostic LEDs for ground faults and overloads Products/10057530?tree=CatalogTree.
• Signaling contact for ground-fault detection
PROFINET
Ground-fault detection
The integrated ground fault detection functions with grounded S7-1200 with DCM 1271, CM 1243-2
and non-grounded power supply: The connection of negative and 24 V standard power supply unit
pole and ground (upstream from the data decoupling module)
customary with 24 V DC power supplies is permitted. A ground
fault to the negative or positive pole on the AS-Interface network
(behind the data decoupling module) is identified and signaled
Up to 50 m
via LED and a transistor output.
■ Benefits AS-Interface
• The AS-Interface system can also be used in tightly budgeted I/O modules
applications because no AS-Interface power supply unit
needs to be purchased
• Applications benefit in addition from the advantages of Configuration of an AS-i Power24V network with AS-Interface DCM 1271
data decoupling module
a modern bus system:
- High level of standardization
- Additional diagnostics and maintenance information
- Faster commissioning
CM 1243-5 communications
module
Communications module for 6GK7243-5DX30-0XE0
electrical connection of SIMATIC
3
S7-1200 to PROFIBUS as a DPV1
master
Accessories
PROFIBUS FastConnect
connection plug RS485
With 90° cable outlet;
insulation displacement technology,
max. transmission rate 12 Mbps
• Without programming device 6ES7972-0BA52-0XA0
• With programming device 6ES7972-0BB52-0XA0
PROFIBUS FC Standard Cable
2-core bus cable, shielded, 6XV1830-0EH10
special design for fast mounting,
delivery unit: max. 1000 m,
minimum order quantity 20 m,
DP-M DP-S FMS PG/OP S7 sold by the meter
PROFIBUS FastConnect
G_IK10_XX_10323
Stripping Tool
Stripping tool for fast stripping of 6GK1905-6AA00
the PROFIBUS FastConnect bus
cable
The CM 1243-5 communications module is used to connect
a SIMATIC S7-1200 to PROFIBUS as a DP master and has PROFIBUS bus terminal 12M
the following characteristics: Bus terminal for connection of 6GK1500-0AA10
• PROFIBUS DPV1 master in accordance with IEC 61158 PROFIBUS nodes up to 12 Mbps
with connecting cable
• Support of up to 16 PROFIBUS DP slaves
• Communication with other S7 controllers based on
S7 communication
• Allows programming devices and operator panels
with PROFIBUS interfaces to be connected to
the SIMATIC S7-1200
• Module replacement without programming device supported
• Support of all standard baud rates from 9.6 kbps to 12 Mbps
• Compact industrial enclosure in SIMATIC S7-1200 design for
mounting on a DIN rail
• Fast commissioning thanks to easy configuration using
STEP 7 without additional programming overhead
The CM 1243-5 is intended for use in factory automation.
Low-cost PROFIBUS-based automation solutions can be
created on the basis of the SIMATIC S7-1200 for optimal
production.
■ Technical specifications
Article number 6GK7243-5DX30-0XE0 Article number 6GK7243-5DX30-0XE0
product type designation CM 1243-5 product type designation CM 1243-5
transfer rate product features, product functions,
transfer rate product components general
3
further nodes to Industrial Ethernet
with 10/100 Mbps;
4 x RJ45 ports; external 24 V DC
power supply, diagnostics on LEDs,
S7-1200 module including
electronic manual on CD-ROM
SIPLUS NET CSM 1277 compact 6AG1277-1AA10-4AA0
switch module
Unmanaged switch for connection
of SIPLUS S7-1200 and up to three
further stations to Industrial
Ethernet with 10/100 Mbps;
4 x RJ45 ports; external 24 V DC
power supply, LED diagnostics,
S7-1200 module including
electronic manual on CD-ROM
Accessories
• Unmanaged switch for connecting a SIMATIC S7-1200 to an IE FC TP trailing cable 2 x 2 6XV1840-3AH10
Industrial Ethernet network with a line, tree or star topology (Type C)
• Multiplication of Ethernet interfaces on a SIMATIC S7-1200 for 4-core, shielded TP installation
additional connection of up to three programming devices, cable for connection to
operator controls, and further Ethernet nodes IE FC outlet RJ45/ IE FC RJ45
plug 180/90 for use as trailing
• Simple, space-saving mounting on the SIMATIC S7-1200 DIN rail cable; PROFINET-compatible;
• Low-cost solution for implementing small, local Ethernet with UL approval;
sold by the meter; max. delivery
networks unit 1 000 m, minimum order
• Connection without any problems using RJ45 standard plug quantity 20 m
connectors IE FC RJ45 plug 180 2 x 2
• Simple and fast status display via LEDs on the device RJ45 plug connector for
• Integral autocrossover function permits use of uncrossed Industrial Ethernet with a rugged
metal housing and integrated
connecting cables insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables;
180° cable outlet; for network
components and CPs/CPUs with
Industrial Ethernet interface
• 1 pack = 1 unit 6GK1901-1BB10-2AA0
• 1 pack = 10 units 6GK1901-1BB10-2AB0
• 1 pack = 50 units 6GK1901-1BB10-2AE0
IE FC outlet RJ45 6GK1901-1FC00-0AA0
For connection of Industrial
Ethernet FC cables and TP cords;
graduated prices for 10 and 50
units or more
IE TP cord RJ45/RJ45
• TP cord pre-assembled 6XV1850-2GE50
with 2 RJ45 plug connectors;
length: 0.5 m
• TP cable 4 x 2 6XV1870-3QE50
with 2 RJ45 plug connectors;
length: 0.5 m
■ Technical specifications
Article number 6GK7277-1AA10-0AA0 Article number 6GK7277-1AA10-0AA0
product type designation SCALANCE CSM 1277 product functions management,
transfer rate configuration, engineering
transfer rate 10 Mbit/s, 100 Mbit/s product function
■ More information
Selection Tool:
To support the selection of SCALANCE network components,
the TIA Selection Tool is available at:
http://www.siemens.com/tst
CP 1243-1 communications
processor
CP 1243-1 communications 6GK7243-1BX30-0XE0
processor for connecting
3
SIMATIC S7-1200 as an additional
Ethernet interface and for
connection to control centers
via telecontrol protocols
(DNP3, IEC 60870, TeleControl
Basic), security (firewall, VPN)
Accessories
Compact Switch Module CSM 1277
Unmanaged switch for connecting 6GK7277-1AA10-0AA0
a SIMATIC S7-1200 and up to three
further nodes to Industrial Ethernet
with 10/100 Mbps; 4 x RJ45 ports;
external 24 V DC power supply,
LED diagnostics, S7-1200 module
including electronic device manual
on CD-ROM
IE FC RJ45 plugs
The CP 1243-1 communications processor is used for
connecting the SIMATIC S7-1200 to telecontrol centers RJ45 connectors for Industrial
via remote networks and telecontrol protocols Ethernet with a rugged metal
enclosure and integrated insulation
(DNP3, IEC 60870-5-104, TeleControl Basic), displacement contacts for
and for safe communication via IP-based networks. connecting Industrial Ethernet FC
installation cables
The CP has the following features:
IE FC RJ45 plug 180
• Ethernet-based connection to TeleControl Server Basic,
e.g. via Internet 180° cable outlet; for network
components and CPs/CPUs with
• Data transfer of measured values, control variables, or alarms Industrial Ethernet interface
optimized for telecontrol systems • 1 pack = 1 unit 6GK1901-1BB10-2AA0
• Automatic sending of alert emails • 1 pack = 10 units 6GK1901-1BB10-2AB0
• 1 pack = 50 units 6GK1901-1BB10-2AE0
• Data buffering of up to 64,000 values ensures a secure
database even with temporary connection failures IE FC TP standard cable GP 2 x 2
(Type A)
• Secure communication via VPN connections based on IPSec
4-core, shielded TP installation 6XV1840-2AH10
• Access protection via stateful inspection firewall cable for connection to
• Support of SINEMA Remote Connect with autoconfiguration IE FC outlet RJ45/IE F RJ45 plug;
PROFINET-compatible;
• Clearly laid out LED signaling for fast and easy diagnostics with UL approval;
sold by the meter;
• Compact industrial enclosure in S7-1200 design for mounting max. length 1 000 m,
on a DIN rail minimum order quantity 20 m
• Fast commissioning thanks to easy configuration using IE FC Stripping Tool
STEP 7
Pre-adjusted stripping tool for fast 6GK1901-1GA00
stripping of Industrial Ethernet FC
cables
■ Technical specifications
Article number 6GK7243-1BX30-0XE0 Article number 6GK7243-1BX30-0XE0
product type designation CP 1243-1 product type designation CP 1243-1
transfer rate supply voltage, current
transfer rate consumption, power loss
• at the 1st interface 10 ... 100 Mbit/s type of voltage of the supply voltage DC
interfaces supply voltage 1 from backplane bus 5 V
number of interfaces acc. to 1 consumed current
Industrial Ethernet • from backplane bus at DC at 5 V 0.25 A
number of electrical connections typical
• at the 1st interface acc. to Industrial 1 power loss [W] 1.25 W
Ethernet
• for power supply 0
type of electrical connection
• at the 1st interface acc. to Industrial RJ45 port
Ethernet
■ Technical specifications
Article number 6GK7243-1BX30-0XE0 Article number 6GK7243-1BX30-0XE0
product type designation CP 1243-1 product type designation CP 1243-1
ambient conditions performance data teleservice
ambient temperature diagnostics function online Yes
3 • for vertical installation during
operation
-20 ... +60 °C diagnostics with SIMATIC STEP 7
product function
• for horizontally arranged busbars -20 ... +70 °C • program download with Yes
during operation SIMATIC STEP 7
• during storage -40 ... +70 °C • remote firmware update Yes
• during transport -40 ... +70 °C product functions management,
relative humidity configuration, engineering
• at 25 °C without condensation 95 % configuration software
during operation maximum • required STEP 7 Basic/Professional
protection class IP IP20 product functions diagnostics
design, dimensions and weights product function web-based Yes
module format Compact module S7-1200 single diagnostics
width product functions security
width 30 mm firewall version stateful inspection
height 110 mm product function with VPN connection IPsec, SINEMA RC
depth 75 mm type of encryption algorithms with AES-256, AES-192, AES-128,
net weight 0.122 kg VPN connection 3DES-168
fastening method type of authentication procedure with Preshared key (PSK), X.509v3
VPN connection certificates
• 35 mm top hat DIN rail mounting Yes
type of hashing algorithms with MD5, SHA-1, SHA-2
• wall mounting Yes VPN connection
product features, product functions, number of possible connections with 8
product components general VPN connection
number of units product function
• per CPU maximum 3 • password protection for Web No
performance data open applications
communication • password protection for teleservice No
number of possible connections for access
open communication • encrypted data transmission Yes
• by means of T blocks maximum like CPU • ACL - IP-based No
performance data S7 • ACL - IP-based for PLC/routing No
communication
• switch-off of non-required services Yes
number of possible connections for
S7 communication • blocking of communication via No
physical ports
• maximum like CPU
• log file for unauthorized access No
performance data IT functions
product functions time
number of possible connections
protocol is supported
• as email client maximum 1
• NTP Yes
performance data telecontrol
• NTP (secure) Yes
suitability for use
time synchronization
• node station No
• from NTP-server Yes
• substation Yes
• from control center Yes
• TIM control center No
control center connection For use with TeleControl Server
Basic, WinCC and PCS7
• by means of a permanent supported
connection
• note Connection to SCADA system via
Telecontrol Server Basic and
Standard Telecontrol protocols
protocol is supported
• DNP3 Yes
• IEC 60870-5 Yes
product function data buffering if Yes; 64,000 events
connection is aborted
number of data points per station 500
maximum
number of stations for direct
communication with Telecontrol
Server Basic
• in send direction maximum 3
• in receive direction maximum 15
Communications processor
CP 1242-7 GPRS1)
Communications processor CP 6GK7242-7KX31-0XE0
1242-7 GPRS V2 for connecting
3
SIMATIC S7-1200 to TeleControl
Server Basic via GSM/GPRS mobile
radio network
Accessories
ANT794-4MR antenna 6NH9860-1AA00
Omnidirectional antenna for GSM
(2G), UMTS (3G) and LTE (4G)
networks; omnidirectional;
weatherproof for indoor and
outdoor use; 5 m cable with
fixed connection to antenna;
SMA connector; including mounting
bracket, screws, wall plugs
ANT794-3M antenna 6NH9870-1AA00
Flat panel antenna for GSM (2G)
networks, for triband with
The CP 1242-7 GPRS V2 communications processor is used to 900/1 800/1 900 MHz; weatherproof
connect a SIMATIC S7-1200 to the globally available GSM/GPRS for indoor/outdoor use, 1.2 m cable
mobile radio network and has the following characteristics: with fixed connection to antenna;
SMA connector, incl. assembly
• Worldwide wireless exchange of data between S7-1200 adhesive tape
controllers and/or between S7-1200 controllers and control 1)
Please note country approvals under:
centers with an Internet connection www.siemens.com/mobilenetwork-approvals
• Communication based on the GPRS (General Packet Radio
Service) mobile wireless service with data transmission
speeds of up to 86 kbps in the downlink and 43 kbps in
■ Technical specifications
the uplink Article number 6GK7242-7KX31-0XE0
• GPRS mode with fixed IP addresses and dynamic IP product type designation CP 1242-7 V2
addresses with standard mobile phone contract transfer rate
• Time synchronization based on NTP (Network Time Protocol) transfer rate
• Sending and receiving of text messages • for GPRS transmission
• LED signaling for fast diagnostics - with downlink maximum 86 kbit/s
• Compact industrial enclosure in S7-1200 design for mounting - with uplink maximum 43 kbit/s
on a DIN rail interfaces
• Fast commissioning thanks to easy configuration using number of interfaces acc. to 0
Industrial Ethernet
STEP 7
number of electrical connections
In conjunction with the TeleControl Server Basic software, the • for external antenna(s) 1
CP 1242-7 forms a telecontrol system with additional properties:
• for power supply 1
• Connection of up to 5000 telecontrol stations to the control number of slots
center via an OPC interface
• for SIM cards 1
• Data buffering in the substations in the event of connection type of electrical connection
failures
• for external antenna(s) SMA socket (50 ohms)
• Central status monitoring of the substations • for power supply 3-pole terminal block
• No special provider services required for fixed IP addresses slot version
• Teleservice access with STEP 7 to the substations via the • for SIM card Standard
Internet
The CP 1242-7 V2 is a new product version of the CP 1242-7.
The concept for process data transmission has been expanded
with a simple data point configuration, which enables
substantially easier commissioning without high programming
overhead and minimizes susceptibility to errors during the
projects implementation phase. CP 1242-7 has also been
equipped with new functions, such as access to the internal web
server of the S7-1200. This opens up numerous new application
areas.
■ Technical specifications
Article number 6GK7242-7KX31-0XE0 Article number 6GK7242-7KX31-0XE0
product type designation CP 1242-7 V2 product type designation CP 1242-7 V2
wireless technology product features, product functions,
type of mobile wireless service product components general
3 • is supported SMS
• is supported GPRS
Yes
Yes
number of units
• per CPU maximum 3
• note GPRS (Multislot Class 10) performance data
type of wireless network is supported number of users/telephone numbers 10
definable maximum
• GSM Yes
performance data open
• UMTS No communication
• LTE No number of possible connections for
operating frequency open communication
• 850 MHz Yes • by means of T blocks maximum like CPU
• 900 MHz Yes performance data IT functions
• 1800 MHz Yes number of possible connections
• 1900 MHz Yes • as email client maximum 1
transmit power performance data telecontrol
• at operating frequency 900 MHz 2W control center connection Telecontrol Server Basic
• at operating frequency 1800 MHz 1W • by means of a permanent supported
connection
• at operating frequency 1900 MHz 1W
• by means of demand-oriented supported
supply voltage, current connection
consumption, power loss
• note Connection to SCADA system using
type of voltage of the supply voltage DC OPC interface
supply voltage external 24 V protocol is supported
supply voltage external at DC rated 24 V • DNP3 No
value
• IEC 60870-5 No
relative positive tolerance at DC 20 %
at 24 V product function data buffering Yes; 64,000 events
if connection is aborted
relative negative tolerance at DC 20 %
at 24 V number of stations for direct
communication with Telecontrol
consumed current Server Basic
• from external supply voltage at DC 0.1 A • in send direction maximum 3
at 24 V typical
• in receive direction maximum 15
• from external supply voltage at DC 0.22 A
at 24 V maximum performance data teleservice
power loss [W] 2.4 W diagnostics function online Yes
diagnostics with SIMATIC STEP 7
ambient conditions
product function
ambient temperature
• program download with Yes
• for vertical installation during -20 ... +60 °C SIMATIC STEP 7
operation
• remote firmware update Yes
• for horizontally arranged busbars -20 ... +70 °C
during operation product functions management,
configuration, engineering
• during storage -40 ... +70 °C
configuration software
• during transport -40 ... +70 °C
• required STEP 7 Basic/Professional
relative humidity
product functions diagnostics
• at 25 °C without condensation 95 %
during operation maximum product function web-based Yes
diagnostics
protection class IP IP20
product functions security
design, dimensions and weights
product function
module format Compact module S7-1200 single
width • password protection for teleservice Yes
access
width 30 mm
• encrypted data transmission Yes
height 100 mm
product functions time
depth 75 mm
protocol is supported
net weight 0.133 kg
• NTP Yes
fastening method
time synchronization
• 35 mm top hat DIN rail mounting Yes
• from control center Yes
• S7-300 rail mounting No
• wall mounting Yes
Communication processor
CP 1243-7 LTE
Communication processor for
connecting SIMATIC S7-1200 to
3
TeleControl Server Basic via
LTE mobile wireless network
• CP 1243-7 LTE EU 6GK7243-7KX30-0XE0
Frequencies in European band:
700, 1 700 MHz
Frequencies in European band:
700, 1 700 MHz
• CP 1243-7 LTE US 6GK7243-7SX30-0XE0
Frequencies in North American
band: 800, 1 800, 2 600 MHz
Accessories
ANT794-4MR antenna 6NH9860-1AA00
Omnidirectional antenna for GSM
(2G), UMTS (3G) and LTE (4G)
networks; omnidirectional;
weatherproof for indoor and
CP 1243-7 LTE is used to connect the S7-1200 to a mobile outdoor use; 5 m cable with fixed
wireless 4th Generation LTE (Long Term Evolution) network. connection to antenna; SMA
connector; including mounting
The increased data rates compared to GPRS and widespread bracket, screws, wall plugs
introduction of LTE open up new areas of application.
The CP1243-7 is characterized by the following properties:
• 1 connection to LTE (4G) mobile wireless network
(various versions for EU and North America)
• Data transfer of measured values, control variables, or alarms
optimized for telecontrol systems
• Operation with fixed IP addresses and dynamic IP addresses
with standard cellular phone contract
• Time synchronization based on NTP (Network Time Protocol)
• "On-demand" connection setup via voice call or SMS
• Sending and receiving of SMS
• Teleservice access with STEP 7 to substations via mobile
wireless networks
• Compact industrial enclosure in S7-1200 design for mounting
on a DIN rail
• Temperature range in operation: -20°C to +70°C
• DIN rail mounting
• Diagnostics LEDs (overall status and details)
• Integrated security functions (VPN and firewall)
• Access to the CPU web server
• Fast commissioning due to simplified configuration with STEP 7
• Data buffering of up to 64 000 values ensures a secure
database even with temporary connection failures
• Support of SINEMA Remote Connect with autoconfiguration
■ Technical specifications
Article number 6GK7243-7KX30- 6GK7243-7SX30- Article number 6GK7243-7KX30- 6GK7243-7SX30-
0XE0 0XE0 0XE0 0XE0
product type designation CP 1243-7 LTE EU CP 1243-7 LTE US product type designation CP 1243-7 LTE EU CP 1243-7 LTE US
transfer rate supply voltage, current
3 transfer rate
• for LTE transmission
consumption, power loss
type of voltage of the supply DC DC
voltage
- with downlink maximum 42 Mbit/s 42 Mbit/s
supply voltage external 24 V 24 V
- with uplink maximum 5.76 Mbit/s 5.76 Mbit/s
supply voltage external at DC 24 V 24 V
interfaces rated value
number of interfaces acc. 0 0 relative positive tolerance at DC 20 % 20 %
to Industrial Ethernet at 24 V
number of electrical connections relative negative tolerance at DC 20 % 20 %
• for external antenna(s) 1 1 at 24 V
• for power supply 1 1 consumed current
number of slots • from external supply voltage 0.1 A 0.1 A
at DC at 24 V typical
• for SIM cards 1 1
• from external supply voltage 0.22 A 0.22 A
type of electrical connection at DC at 24 V maximum
• for external antenna(s) SMA socket SMA socket ambient conditions
(50 ohms) (50 ohms)
ambient temperature
• for power supply 3-pole terminal 3-pole terminal
block block • for vertical installation -20 ... +60 °C -20 ... +60 °C
during operation
slot version
• for horizontally arranged -20 ... +70 °C -20 ... +70 °C
• for SIM card Standard Standard busbars during operation
wireless technology • during storage -40 ... +70 °C -40 ... +70 °C
type of mobile wireless service • during transport -40 ... +70 °C -40 ... +70 °C
• is supported SMS Yes Yes relative humidity
• is supported GPRS Yes Yes • at 25 °C without condensation 95 % 95 %
• note GPRS (Multislot GPRS (Multislot during operation maximum
Class 10) Class 10) protection class IP IP20 IP20
type of wireless network is design, dimensions and weights
supported
module format Compact module Compact module
• GSM Yes Yes S7-1200 single S7-1200 single
• UMTS Yes Yes width width
• LTE Yes Yes width 30 mm 30 mm
operating frequency height 100 mm 100 mm
• 850 MHz Yes depth 75 mm 75 mm
• 1900 MHz Yes net weight 0.133 kg 0.133 kg
operating frequency for operating fastening method
GSM transmission frequency for • 35 mm top hat DIN rail mounting Yes Yes
GSM transmission
900 MHz, operat- • S7-300 rail mounting No No
ing frequency for • wall mounting Yes Yes
GSM transmis-
sion 1800 MHz product features, product
functions, product components
operating frequency with operating general
UMTS transmission frequency with
UMTS transmis- number of units
sion 900 MHz, • per CPU maximum 3 3
operating
frequency with
UMTS transmis-
sion 2100 MHz
operating frequency for operating fre- operating
LTE transmission quency for LTE frequency for
transmission LTE transmission
800 MHz, operat- 700 MHz, operat-
ing frequency for ing frequency for
LTE transmission LTE transmission
1800 MHz, oper- 1700 MHz
ating frequency
for LTE transmis-
sion 2600 MHz
■ Technical specifications
Article number 6GK7243-7KX30- 6GK7243-7SX30- Article number 6GK7243-7KX30- 6GK7243-7SX30-
0XE0 0XE0 0XE0 0XE0
product type designation CP 1243-7 LTE EU CP 1243-7 LTE US product type designation CP 1243-7 LTE EU CP 1243-7 LTE US
performance data product functions management,
number of users/telephone
numbers definable maximum
10 10 configuration, engineering
configuration software 3
performance data open • required STEP 7 Basic/ STEP 7 Basic/
communication Professional Professional
number of possible connections product functions diagnostics
for open communication product function web-based Yes Yes
• by means of T blocks maximum like CPU like CPU diagnostics
performance data IT functions product functions security
number of possible connections firewall version stateful inspection stateful inspection
• as email client maximum 1 1 product function with VPN IPsec, IPsec,
performance data telecontrol connection SINEMA RC SINEMA RC
suitability for use type of encryption algorithms with AES-256, AES-256,
VPN connection AES-192, AES-192,
• substation Yes Yes AES-128, AES-128,
control center connection Telecontrol Server Telecontrol Server 3DES-168, 3DES-168,
Basic Basic DES-56 DES-56
• by means of a permanent supported supported type of authentication procedure Preshared key Preshared key
connection with VPN connection (PSK), X.509v3 (PSK), X.509v3
certificates certificates
• by means of demand-oriented supported supported
connection type of hashing algorithms with MD5, SHA-1 MD5, SHA-1
VPN connection
• note Connection to Connection to
SCADA system SCADA system number of possible connections 1 1
using OPC using OPC with VPN connection
interface interface product function
protocol is supported • password protection for Yes Yes
• DNP3 No No teleservice access
• IEC 60870-5 No No • encrypted data transmission Yes Yes
product function data buffering if Yes; 64,000 Yes; 64,000 product functions time
connection is aborted events events protocol is supported
number of stations for direct • NTP Yes Yes
communication with Telecontrol
Server Basic time synchronization
• in send direction maximum 3 3 • from control center Yes Yes
• in receive direction maximum 15 15
performance data teleservice
diagnostics function online Yes Yes
diagnostics with SIMATIC STEP 7
product function
• program download with Yes Yes
SIMATIC STEP 7
• remote firmware update Yes Yes
3
the SINAUT ST7 telecontrol protocol
to higher-level ST7 stations or to an
ST7 control center, or a DNP3 or
IEC-capable control center via
a corresponding DNP3 or
IEC 60870-5-104 open telecontrol
protocols
Accessories
SINAUT engineering software 6NH7997-0CA55-0AA0
V5.5 + SP3
On CD, consisting of:
• SINAUT ST7/DNP3 configuration
and diagnostic software for
STEP 7 V5.6
• SINAUT TD7 block library
• Electronic manual in German
The CP 1243-8 IRC (Industrial Remote Communication) and English
communications processor is used for connecting SINAUT engineering software V5.5 6NH7997-0CA55-0GA0
a SIMATIC S7-1200 via the SINAUT ST7 telecontrol protocol Upgrade from V5.0, V5.1, V5.2, V5.3
to higher-level ST7 stations or to an ST7 control center. or V5.4
The CP 1243-8 IRC (as of HW2 and firmware V3.0) also offers TeleService module
connection to a DNP3 or IEC-capable control center via
Connection to TS Adapter IE
a corresponding open DNP3 or IEC 60870-5-104 telecontrol Basic/Advanced or CP 1243-8 IRC.
protocol. The CP 1243-8 IRC (as of HW2 and firmware V3.0) also Power supply via TS Adapter IE
offers connection to a DNP3 or IEC-capable control center via Basic/Advanced or CP 1243-8 IRC.
a corresponding open DNP3 or IEC 60870-5-104 telecontrol TS module RS 232 6ES7972-0MS00-0XA0
protocol.
TS module modem 6ES7972-0MM00-0XA0
The CP has the following features:
TS module ISDN 6ES7972-0MD00-0XA0
• Support for telecontrol protocol SINAUT ST7, DNP3,
CSM 1277 compact switch 6GK7277-1AA10-0AA0
IEC 60870-5-104 module
• Two WAN connections for selecting the communication paths: Unmanaged switch for connecting
- Ethernet-based connection: RJ45 port on the module for a SIMATIC S7-1200 and up to three
connecting external routers, e.g. SCALANCE M further nodes to Industrial Ethernet
- Additional connection configurable via plug-in TS modules with 10/100 Mbps; 4 x RJ45 ports;
external 24 V DC power supply,
• Both WAN interfaces can also be operated simultaneously: LED diagnostics, S7-1200 module
Route redundancy including electronic device manual
on CD-ROM
• Data transfer of measured values, control variables, or alarms
optimized for telecontrol systems 1)
Please note country approvals under:
• Automatic transmission of alarms per email or text message http://www.siemens.com/mobilenetwork-approvals.
■ Technical specifications
Article number 6GK7243-8RX30-0XE0 Article number 6GK7243-8RX30-0XE0
product type designation CP 1243-8 IRC product type designation CP 1243-8 IRC
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-1200 single
• at the 1st interface
• at the 2nd interface
10 ... 100 Mbit/s
0.3 ... 115.2 kbit/s width
width
30 mm
3
interfaces height 110 mm
number of interfaces acc. to Industrial 1 depth 75 mm
Ethernet net weight 0.122 kg
number of electrical connections fastening method
• at the 1st interface acc. to Industrial 1 • 35 mm top hat DIN rail mounting Yes
Ethernet • S7-300 rail mounting No
• for power supply 1 • wall mounting Yes
type of electrical connection product features, product functions,
• at the 1st interface acc. to Industrial RJ45 port product components general
Ethernet number of units
type of electrical connection • per CPU maximum 1
• at interface 2 for external data Interface to the TS Module • note One CP pluggable on left side of
transmission CPU, one TS Module pluggable left
• for power supply 3-pole terminal block side of CP.
supply voltage, current performance data open
consumption, power loss communication
type of voltage of the supply voltage DC number of possible connections for
supply voltage 1 from backplane bus 5 V open communication
supply voltage external 24 V • by means of T blocks maximum like CPU
supply voltage external 19.2 ... 28.8 V performance data S7
communication
supply voltage external at DC rated 24 V
value number of possible connections for
S7 communication
supply voltage external at DC rated 19.2 ... 28.8 V
value • maximum Configured S7-Connection for
ST7-Communication
consumed current
• with PG connections maximum 2
• from backplane bus at DC at 5 V 0.25 A
typical • with OP connections maximum 1
• from external supply voltage at DC at 0.1 A service
24 V typical • SINAUT ST7 via S7 communication Yes
power loss [W] 2.4 W; 1.25 W from S7-1200 performance data IT functions
backplane without TS module. number of possible connections
2.4 W from 24 V DC external with
TS module • as email client maximum 1
ambient conditions
ambient temperature
• for vertical installation during -20 ... +60 °C
operation
• for horizontally arranged busbars -20 ... +70 °C
during operation
• during storage -40 ... -70 °C
• during transport -40 ... +70 °C
relative humidity
• at 25 °C without condensation 95 %
during operation maximum
protection class IP IP20
■ Technical specifications
Article number 6GK7243-8RX30-0XE0 Article number 6GK7243-8RX30-0XE0
product type designation CP 1243-8 IRC product type designation CP 1243-8 IRC
performance data telecontrol product functions diagnostics
suitability for use product function web-based Yes
3 • node station
• substation
No
Yes
diagnostics
product functions security
• TIM control center No firewall version stateful inspection
• note Ethernet and TS Module can be operating mode Virtual Private Yes
operated in parallel Network (VPN)
control center connection control center with ST7 function product function with VPN connection IPsec, SINEMA RC
• by means of a permanent supported type of encryption algorithms with AES-256, AES-192, AES-128,
connection VPN connection 3DES-168, DES-56
protocol is supported type of authentication procedure with Preshared key (PSK),
VPN connection X.509v3 certificates
• DNP3 Yes
type of hashing algorithms with MD5, SHA-1
• IEC 60870-5 Yes VPN connection
• SINAUT ST7 protocol Yes number of possible connections with 8
product function data buffering if Yes; DNP3, IEC60870-5: VPN connection
connection is aborted 64000 events, product function
SINAUT ST7: 16000 telegrams
• password protection for teleservice No
number of data points per station 500 access
maximum
• encrypted data transmission Yes
transmission format
• MSC client via GPRS modem with Yes
• for SINAUT ST7 protocol with Yes MSC capability
multi-master polling 10-bit
protocol
• for SINAUT ST7 protocol with polling Yes
or spontaneous 10-bit or 11-bit • is supported MSC protocol Yes
operating mode for scanning of data • with Virtual Private Network MSC is TCP/IP
transmission supported
• with dedicated line/radio link with Polling key length for MSC with Virtual Private 128 bit
SINAUT ST7 protocol Network
• with dial-up network with spontaneous number of possible connections
SINAUT ST7 protocol • as MSC client with VPN connection 1
hamming distance • as MSC server with VPN connection 0
• for SINAUT ST7 protocol 4 product functions time
performance data teleservice protocol is supported
diagnostics function online Yes • NTP Yes
diagnostics with SIMATIC STEP 7 time synchronization
product function • from NTP-server Yes
• program download with Yes • from control center Yes
SIMATIC STEP 7
accessories
• remote firmware update Yes
accessories TS Module RS232 or
product functions management, TS Module MODEM or
configuration, engineering TS Module ISDN or
protocol is supported TS Module GSM pluggable
• SNMP v3 Yes
• DCP Yes
configuration software
• required SINAUT ES V5.5 and STEP7 V13 SP1
or higher
• for PG configuring required Yes
SINAUT ST7 configuration
software for PG
■ Technical specifications
Article number 6GT2002-0LA00 Article number 6GT2002-0LA00
product type designation RF120C communications module product type designation RF120C communications module
transfer rate design, dimensions and weights
transfer rate at the point-to-point 115.2 kbit/s width 30 mm
3 connection serial maximum
interfaces
height
depth
100 mm
75 mm
design of the interface for RS422/RS232 net weight 0.15 kg
point-to-point connection
fastening method S7-1200 rack
number of readers connectable 1
wire length for RS 422 interface 1 000 m
type of electrical connection maximum
• of the backplane bus S7-1200 backplane bus product features, product functions,
• for supply voltage Screw terminals product components general
design of the interface to the reader sub-D, 9-pin, female display version 4 LEDs for reader connection,
for communication 1 LED for device status
mechanical data product function addressable No
material Xantar MX 1094 transponder file handler
color Ti-grey 24L01 protocol is supported
tightening torque of the screw for 0.45 N·m • S7 communication Yes
securing the equipment maximum product functions management,
supply voltage, current configuration, engineering
consumption, power loss type of programming ID profile, library with functions
supply voltage type of computer-switched acyclic communication
• at DC rated value 24 V communication
• at DC 20 ... 30 V standards, specifications, approvals
consumed current at DC at 24 V certificate of suitability CE, FCC, cULus, KCC, C-Tick, FM
• without connected devices typical 0.03 A certificate of suitability
• with connected devices maximum 1A • IECEx Yes
ambient conditions • for IECEx as marking Ex: II 3G Ex nAA IIC T4 Gc
ambient temperature MTBF 196 y
• during operation 0 ... 55 °C
• during storage -40 ... +70 °C
• during transport -40 ... +70 °C
protection class IP IP20
shock resistance According to IEC 61131-2
shock acceleration 300 m/s²
vibrational acceleration 100 m/s²
SIPLUS CM 1241
communications module
(Extended temperature range and
exposure to media)
Ambient temperature -40 ... +70° C
Communications module for 6AG1241-1AH32-2XB0
3
point-to-point connection,
with one RS 232 interface
Communications module for 6AG1241-1CH32-2XB0
point-to-point connection,
with one RS 485 interface
Suitable for areas with
extreme exposure to media
(conformal coating)
Communications module for 6AG1241-1AH32-4XB0
point-to-point connection,
with one RS 232 interface
Communications module for 6AG1241-1CH32-4XB0
point-to-point connection,
• For fast, high-performance serial data exchange via with one RS 485 interface
point-to-point coupling Accessories See SIMATIC S7-1200
communications module
• Implemented protocols: ASCII, USS drive protocol, CM 1241, page 3/128
Modbus RTU
• Additional protocols can also be loaded
• Simple parameterization with STEP 7 Basic
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1241-1AH32-4XB0 6AG1241-1AH32-2XB0 6AG1241-1CH32-4XB0 6AG1241-1CH32-2XB0
Based on 6ES7241-1AH32-0XB0 6ES7241-1AH32-0XB0 6ES7241-1CH32-0XB0 6ES7241-1CH32-0XB0
SIPLUS S7-1200 CM 1241 SIPLUS S7-1200 CM1241 SIPLUS S7-1200 CM 1241 SIPLUS S7-1200 CM 1241
RS232 RS232 RS422/485 RS422/485
Ambient conditions
Ambient temperature
during operation
• min. -20 °C; = Tmin -40 °C; = Tmin -20 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ -25 °C start-up @ 0 °C start-up @ -25 °C
• max. 60 °C; = Tmax 70 °C; = Tmax 60 °C; = Tmax 70 °C; Tmax > 60 °C,
derating: Max. one module
may be configured; this
module must be the last
module on the CM bus;
minimum clearance on the
left side of at least 45 mm
Altitude during operation
relating to sea level
• Installation altitude above sea level, max. 5 000 m 5 000 m 5 000 m 5 000 m
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
■ Technical specifications
Article number 6AG1241-1AH32-4XB0 6AG1241-1AH32-2XB0 6AG1241-1CH32-4XB0 6AG1241-1CH32-2XB0
Based on 6ES7241-1AH32-0XB0 6ES7241-1AH32-0XB0 6ES7241-1CH32-0XB0 6ES7241-1CH32-0XB0
SIPLUS S7-1200 CM 1241 SIPLUS S7-1200 CM1241 SIPLUS S7-1200 CM 1241 SIPLUS S7-1200 CM 1241
RS232 RS232 RS422/485 RS422/485
■ Technical specifications
Article number 6AG1241-1CH30-5XB1 Article number 6AG1241-1CH30-5XB1
Based on 6ES7241-1CH30-1XB0 Based on 6ES7241-1CH30-1XB0
SIPLUS S7-1200 CB 1241 RS485 SIPLUS S7-1200 CB 1241 RS485
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold and fungal
during operation according to EN 60721-3-6 spores (excluding fauna);
• min. -40 °C; = Tmin Class 6B3 on request
(incl. condensation/frost); - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt
start-up @ -25 °C according to EN 60721-3-6 spray acc. to EN 60068-2-52
• max. 60 °C; = Tmax (severity degree 3); *
Altitude during operation - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
relating to sea level according to EN 60721-3-6
• Installation altitude above sea level, 5 000 m Usage in industrial process
max. technology
• Ambient air temperature-barometric Tmin ... Tmax at - Against chemically active Yes; Class 3 (excluding
pressure-altitude 1 140 hPa ... 795 hPa substances acc. to EN 60654-4 trichlorethylene)
(-1 000 m ... +2 000 m) // - Environmental conditions for Yes; Level GX group A/B
Tmin ... (Tmax - 10 K) at process, measuring and control (excluding trichlorethylene;
795 hPa ... 658 hPa systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
(+2 000 m ... +3 500 m) // the limits of EN 60721-3-3 class 3C4
Tmin ... (Tmax -20 K) at permissible); level LC3 (salt spray)
658 hPa ... 540 hPa and level LB3 (oil)
(+3 500 m ... +5 000 m) Remark
Relative humidity - Note regarding classification of * The supplied plug covers must
• With condensation, tested in 100 %; RH incl. condensation/frost environmental conditions acc. to remain in place over the unused
accordance with IEC 60068-2-38, (no commissioning under EN 60721, EN 60654-4 and interfaces during operation!
max. condensation conditions) ANSI/ISA-71.04
Resistance Conformal coating
Coolants and lubricants • Coatings for printed circuit board Yes; Class 2 for high reliability
- Resistant to commercially Yes; Incl. diesel and oil droplets in assemblies acc. to EN 61086
available coolants and lubricants the air • Protection against fouling acc. to Yes; Type 1 protection
Use in stationary industrial systems EN 60664-3
- to biologically active substances Yes; Class 3B2 mold, fungus and dry • Military testing according to Yes; Discoloration of coating
according to EN 60721-3-3 rot spores (with the exception of MIL-I-46058C, Amendment 7 possible during service life
fauna); Class 3B3 on request • Qualification and Performance of Yes; Conformal coating, Class A
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Electrical Insulating Compound for
according to EN 60721-3-3 spray acc. to EN 60068-2-52 Printed Board Assemblies
(severity degree 3); * according to IPC-CC-830A
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
3
to media (e.g. sulfur chlorine
atmosphere).
Technical specifications The technical data of the standard
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity 100%, condensation/frost
permissible. No commissioning
if condensation present.
Biologically active substances, Class 3B2 mold and fungal spores
compliance with EN 60721-3-3 (excluding fauna). The supplied plug
covers must remain in place over the
unused interfaces during operation!
Chemically active substances, Class 3C4 incl. salt spray in
compliance with EN 60721-3-3 accordance with EN60068-2-52
(degree of severity 3). The supplied
DP-M DP-S FMS PG/OP S7 plug covers must remain in place
over the unused interfaces during
operation!
G_IK10_XX_10322
3
to media (e.g. sulfur chlorine
atmosphere).
Technical specifications The technical data of the standard
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity 100%, condensation/frost
permissible. No commissioning
if condensation present.
Biologically active substances, Class 3B2 mold and fungal spores
compliance with EN 60721-3-3 (excluding fauna). The supplied plug
covers must remain in place over the
unused interfaces during operation!
Chemically active substances, Class 3C4 incl. salt spray in
compliance with EN 60721-3-3 accordance with EN60068-2-52
(degree of severity 3). The supplied
DP-M DP-S FMS PG/OP S7 plug covers must remain in place
over the unused interfaces during
operation!
G_IK10_XX_10323
SIPLUS CP 1243-1
communications module
(Extended temperature range and
exposure to environmental
3
substances)
Communications processor for 6AG1243-1BX30-2AX0
connecting SIMATIC S7-1200 as an
additional Ethernet interface and for
connection to control centers via
telecontrol protocols (DNP3,
IEC 60870, TeleControl Basic),
security (firewall, VPN)
Accessories See communications processor
SIMATIC S7-1200 CP 1243-1,
page 3/141
■ Technical specifications
Article number 6AG1243-1BX30-2AX0 Article number 6AG1243-1BX30-2AX0
Based on 6GK7243-1BX30-0XE0 Based on 6GK7243-1BX30-0XE0
product type designation SIPLUS S7-1200 CP 1243-1 product type designation SIPLUS S7-1200 CP 1243-1
ambient conditions resistance to chemically active
3 ambient temperature
• for vertical installation during -40 ... +60 °C
substances
• conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt
operation spray in accordance with
EN 60068-2-52 (Severity 3).
• for horizontally arranged busbars -40 ... +70 °C The supplied plug covers must
during operation remain in place on the unused
• during storage -40 ... +70 °C interfaces during operation.
• during transport -40 ... +70 °C • conformity acc. to EN 60721-3-6 Yes
installation altitude at height above 5 000 m resistance to mechanically active
sea level maximum substances
ambient condition relating to ambient Tmin ... Tmax at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
temperature - air pressure - 1 140 hPa ... 795 hPa The supplied plug covers must
installation altitude (-1 000 m ... +2 000 m) // remain in place over the unused
Tmin ... (Tmax - 10 K) at interfaces during operation.
795 hPa ... 658 hPa • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
(+2 000 m ... +3 500 m) // The supplied plug covers must
Tmin ... (Tmax - 20 K) at remain in place over the unused
658 hPa ... 540 hPa interfaces during operation.
(+3 500 m ... +5 000 m)
coating for equipped printed circuit Yes; Class 2 for high availability
relative humidity board acc. to EN 61086
• with condensation acc. to 100 %; RH including type of coating protection against Yes; Protection of the type 1
IEC 60068-2-38 maximum condensation/frost pollution according to EN 60664-3
(no commissioning when
condensation is present), type of test of the coating acc. to Yes; Coating discoloration during
horizontal installation MIL-I-46058C service life possible
chemical resistance to commercially Yes; incl. airborne diesel and oil product conformity of the coating Yes; Conformal coating, class A
available cooling lubricants droplets Qualification and Performance of
Electrical Insulating Compound for
resistance to biologically active Printed Board Assemblies acc. to
substances IPC-CC-830A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal protection class IP IP20
spores (excluding fauna),
Class 3B3 on request
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and
dry rot spores (excluding fauna)
■ Overview
The wiring of the
• SIMATIC S7-1500 IO (25 mm)
• SIMATIC ET 200SP
• SIMATIC S7-1200
3 • LOGO!
with the sensors/actuators is a significant factor with respect to
time/cost overhead during configuration, control cabinet design,
procurement and ease of servicing. The SIMATIC TOP connect
system cabling makes connection easy, fast and secure.
■ Design
The unshielded universal connection cable is offered for a wide • 16-pin ID connector (insulation displacement) for connection
range of control cabinet concepts. to the SIMATIC TOP connect terminal modules for 8 I/Os:
- 3-wire connection using the appropriate terminal module for
It comprises: quick, error-free, wiring
• 16-pin round cable with a core diameter of 0.14 mm2, - Galvanic isolation and adaptation using a coupling relay for
pre-assembled with wire end ferrules for connection easy implementation of potential groups in the system
to the controller: - High output current (up to 4 A), even for higher switching
- labeled with "0" … "7" for the control inputs/outputs frequencies, using an optocoupler module (overload and
- labeled with "M" for mass short-circuit proof)
- labeled with "L+" for 24 V DC potential - Implementation of isolating terminals using switch modules
enabling individual signals to be measured
- Channel-wise protection of I/Os using a fuse module with
a thermal fuse
SIMATIC S7-1500,
I/O module (25 mm) incl.
front connector module
3
8 inputs 24 V DC (SIL 3/category 3
or category 4/PL e)
or a combination of both
Accessories
Terminal block (spare part)
With 11 screws, tin-coated; 4 units 6ES7292-1AL30-0XA0
Front flap set (spare part)
For modules with a width of 70 mm 6ES7291-1BB30-0XA0
STEP 7 Safety Advanced V17
Task:
Engineering tool for configuring and
programming fail-safe user
programs for SIMATIC S7-1200 FC,
S7-1500F, S7-1500F Software
Controller, S7-300F, S7-400F,
• Digital inputs as supplement to the integral I/O of the CPUs WinAC RTX F, ET 200SP F
• Integrated into the overall automation for the implementation Controller and the fail-safe
ET 200SP, ET 200MP, ET 200S,
of safety-related requirements ET 200M, ET 200iSP, ET 200pro and
• With integrated safety functions ET 200eco I/O
Requirement:
• Communication with fail-safe CPUs via PROFIsafe STEP 7 Professional V17
mechanisms Note:
• For flexible adaptation of the controller to the corresponding task As of TIA Portal V16,
• For subsequent expansion of the system with additional inputs the SIMATIC STEP 7 Safety software
is an integral component of the
• Operable exclusively in the central system SIMATIC STEP 7 product setup.
The functionality of SIMATIC STEP 7
Safety is activated by means of the
license key supplied in each case.
Floating license for 1 user; 6ES7833-1FA17-0YA5
license key on USB flash drive
Floating license for 1 user; 6ES7833-1FA17-0YH5
license key for download1);
Email address required for delivery
STEP 7 Safety Basic V17
Task:
Engineering tool for configuring
fail-safe user programs for
SIMATIC S7-1200 FC
Requirement:
STEP 7 Basic V17 and higher
Note:
As of TIA Portal V16,
the SIMATIC STEP 7 Safety software
is an integral component of the
SIMATIC STEP 7 product setup.
The functionality of SIMATIC STEP 7
Safety is activated by means of the
license key supplied in each case.
Floating license for 1 user; 6ES7833-1FB17-0YA5
license key on USB flash drive
Floating license for 1 user; 6ES7833-1FB17-0YH5
license key for download1);
email address required for delivery
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7226-6BA32-0XB0 Article number 6ES7226-6BA32-0XB0
Digital Input SM 1226, Digital Input SM 1226,
F-DI 16x 24VDC F-DI 16x 24VDC
General information Standards, approvals, certificates
Product type designation
Supply voltage
SM 1226, F-DI 16x24 V DC CE mark
cULus
Yes
Yes
3
Rated value (DC) 24 V FM approval Yes
Input current Highest safety class achievable in
from backplane bus 5 V DC, max. 155 mA; Current consumption safety mode
(SM Bus, 5 V DC): 155 mA • Performance level according to 1-channel, Category 3,
Digital inputs ISO 13849-1 PL d;
2-channel, Category 3 or 4,
• from load voltage L+ (without load), 130 mA; 130 mA + 6 mA / input used + PL e
max. any Vs1/Vs2 current used
• SIL acc. to IEC 61508 SIL 2 (single-channel),
Digital inputs SIL 3 (two-channel)
Number of digital inputs 16; 16 (1oo1) or 8 (1oo2); Ambient conditions
Note: You can individually assign
each pair of inputs "a.x" and "b.x" as Ambient temperature during
a single (1oo2)-channel or as operation
2 separate (1oo1)-channels • min. 0 °C
horizontal installation • max. 55 °C
- up to 50 °C, max. 16; 16 inputs at 55 °C horizontal Mechanics/material
vertical installation Enclosure material (front)
- up to 40 °C, max. 16; 16 inputs at 45 °C vertical • Plastic Yes
Input voltage Dimensions
• for signal "0" -30 V DC to +5 V DC Width 70 mm
• for signal "1" 15 V DC to 30 V DC Height 100 mm
Input current Depth 75 mm
• for signal "0", max. 0.5 mA Weights
(permissible quiescent current) Weight, approx. 250 g
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.8 / 1.6 / 3.2 / 6.4 / 12.8 ms
Diagnostics indication LED
• for status of the inputs Yes
3 Accessories
Terminal block (spare part)
With 11 screws, tin-coated; 4 units 6ES7292-1AL30-0XA0
Front flap set (spare part)
For modules with a width of 70 mm 6ES7291-1BB30-0XA0
STEP 7 Safety Advanced V17
Task:
Engineering tool for configuring and
programming fail-safe user
programs for SIMATIC S7-1200 FC,
S7-1500F, S7-1500F Software
Controller, S7-300F, S7-400F,
WinAC RTX F, ET 200SP F
Controller and the fail-safe I/O
ET 200SP, ET 200MP, ET 200S,
• Digital outputs as a supplement to the integral I/O of the CPUs ET 200M, ET 200iSP, ET 200pro and
• Integrated into the overall automation for the implementation ET 200eco
Requirement:
of safety-related requirements STEP 7 Professional V17
• With integrated safety functions Note:
• Communication with fail-safe CPUs via PROFIsafe As of TIA Portal V16,
mechanisms the SIMATIC STEP 7 Safety software
is an integral component of the
• For flexible adaptation of the controller to the corresponding task SIMATIC STEP 7 product setup.
• For subsequent expansion of the system with additional The functionality of SIMATIC STEP 7
Safety is activated by means of the
outputs license key supplied in each case.
• Operable exclusively in the central system Floating license for 1 user; 6ES7833-1FA17-0YA5
license key on USB flash drive
Floating license for 1 user; 6ES7833-1FA17-0YH5
license key for download1);
Email address required for delivery
STEP 7 Safety Basic V17
Task:
Engineering tool for configuring
fail-safe user programs for
SIMATIC S7-1200 FC
Requirement:
STEP 7 Basic V17 and higher
Note:
As of TIA Portal V16,
the SIMATIC STEP 7 Safety software
is an integral component of the
SIMATIC STEP 7 product setup.
The functionality of SIMATIC STEP 7
Safety is activated by means of the
license key supplied in each case.
Floating license for 1 user; 6ES7833-1FB17-0YA5
license key on USB flash drive
Floating license for 1 user; 6ES7833-1FB17-0YH5
license key for download1);
email address required for delivery
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7226-6DA32-0XB0 Article number 6ES7226-6DA32-0XB0
Digital Output SM 1226, Digital Output SM 1226,
F-DQ 4x 24VDC F-DQ 4x 24VDC
General information Standards, approvals, certificates
Product type designation
Input current
SM 1226 F-DQ 4x 24 VDC CE mark
cULus
Yes
Yes
3
from backplane bus 5 V DC, max. 125 mA FM approval Yes
Digital outputs Highest safety class achievable
• from load voltage L+, max. 170 mA in safety mode
Digital outputs • Performance level according to Category 4, PL e
ISO 13849-1
Number of digital outputs 4
• SIL acc. to IEC 61508 SIL 3
• in groups of 1
Ambient conditions
Short-circuit protection Yes
Ambient temperature
Switching capacity of the outputs during operation
• with resistive load, max. 30 Hz • min. 0 °C
• on lamp load, max. 10 Hz • max. 55 °C
Output voltage Mechanics/material
• Rated value (DC) 24 V Enclosure material (front)
Output current • Plastic Yes
• for signal "1" rated value 2A Dimensions
• for signal "0" residual current, max. P-switch: 0.5 mA, maximum; Width 70 mm
M-switch: 0.5 mA, maximum
Height 100 mm
Diagnostics indication LED
Depth 75 mm
• for status of the outputs Yes
Weights
Weight, approx. 270 g
■ Technical specifications
Article number 6ES7226-6RA32-0XB0 Article number 6ES7226-6RA32-0XB0
Digital Output SM 1226, Digital Output SM 1226,
F-DQ 2x Relay F-DQ 2x Relay
General information Standards, approvals, certificates
Product type designation
Input current
SM 1226, F-DQ 2x relay/5 A CE mark
cULus
Yes
Yes
3
from backplane bus 5 V DC, max. 120 mA FM approval Yes
Digital outputs Highest safety class achievable
• from load voltage L+, max. 300 mA in safety mode
Digital outputs • Performance level according Category 4, PL e
to ISO 13849-1
Number of digital outputs 2
• SIL acc. to IEC 61508 SIL 3
Short-circuit protection No
Ambient conditions
Output voltage
Ambient temperature
• Rated value (DC) 5 V DC to 30 V DC during operation
• Rated value (AC) 5 V AC to 250 V AC • min. 0 °C
Relay outputs • max. 55 °C
• Number of relay outputs 2; 2 circuits per output Mechanics/material
Switching capacity of contacts Enclosure material (front)
- with inductive load, max. 0.1 Hz, accordance with • Plastic Yes
IEC 60947-5-1, DC-13; 2 Hz,
accordance with IEC 60947-5-1, Dimensions
AC-15 Width 70 mm
- with resistive load, max. 2 Hz Height 100 mm
Diagnostics indication LED Depth 75 mm
• for status of the outputs Yes Weights
Weight, approx. 300 g
3 Ambient conditions
Ambient temperature during
operation
• min. -25 °C; = Tmin
• max. 55 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under
• Digital inputs as supplement to the integral I/O of the CPUs max. condensation conditions)
• Integrated into the overall automation for the implementation Resistance
of safety-related requirements Coolants and lubricants
• With integrated safety functions - Resistant to commercially Yes
available coolants and lubricants
• Communication with fail-safe CPUs via PROFIsafe Use in stationary industrial systems
mechanisms
- to biologically active substances Yes; Class 3B2 mold, fungus and dry
• For flexible adaptation of the controller to the corresponding according to EN 60721-3-3 rot spores (with the exception of
task fauna); Class 3B3 on request
• For subsequent expansion of the system with additional inputs - to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52
• Operable exclusively in the central system (severity degree 3); *
Note - to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
SIPLUS extreme products are based on SIMATIC standard Use on ships/at sea
products. The contents listed here were taken from the - to biologically active substances Yes; Class 6B2 mold and fungal
respective standard products. SIPLUS extreme-specific according to EN 60721-3-6 spores (excluding fauna);
information was added. Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt
■ Ordering data Article No. according to EN 60721-3-6 spray acc. to EN 60068-2-52
(severity degree 3); *
SIPLUS SM 1226 fail-safe digital 6AG1226-6BA32-5XB0 - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
input signal module according to EN 60721-3-6
Usage in industrial process
(Extended temperature range and technology
environmental stress)
- Against chemically active Yes; Class 3 (excluding
16 inputs, 24 V DC substances acc. to EN 60654-4 trichlorethylene)
(SIL 2/category 3/PL d) or
8 inputs 24 V DC (SIL 3/category 3 - Environmental conditions for Yes; Level GX group A/B (excluding
or category 4/PL e) process, measuring and control trichlorethylene; harmful gas
or a combination of both systems acc. to ANSI/ISA-71.04 concentrations up to the limits of
EN 60721-3-3 class 3C4
Accessories See SIMATIC SM 1226 permissible); level LC3 (salt spray)
fail-safe digital input signal module, and level LB3 (oil)
page 3/164 Remark
- Note regarding classification of * The supplied plug covers must
environmental conditions acc. to remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life
• Qualification and Performance of Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
3 Ambient conditions
Ambient temperature during
operation
• min. -25 °C; = Tmin
• max. 55 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under
• Relay outputs as a supplement to the integral I/O of the CPUs max. condensation conditions)
• Integrated into the overall automation for the implementation Resistance
of safety-related requirements Coolants and lubricants
• With integrated safety functions - Resistant to commercially Yes
available coolants and lubricants
• Communication with fail-safe CPUs via PROFIsafe mechanisms Use in stationary industrial systems
• For flexible adaptation of the controller to the corresponding task - to biologically active substances Yes; Class 3B2 mold, fungus and dry
• For subsequent expansion of the system with additional outputs according to EN 60721-3-3 rot spores (with the exception of
fauna); Class 3B3 on request
• Operable exclusively in the central system - to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt
Note according to EN 60721-3-3 spray acc. to EN 60068-2-52
(severity degree 3); *
SIPLUS extreme products are based on SIMATIC standard - to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
products. The contents listed here were taken from the according to EN 60721-3-3
corresponding standard products. SIPLUS extreme-specific Use on ships/at sea
information was added. - to biologically active substances Yes; Class 6B2 mold and fungal
according to EN 60721-3-6 spores (excluding fauna);
■ Ordering data Article No.
- to chemically active substances
Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl. salt
SIPLUS SM 1226 fail-safe relay 6AG1226-6RA32-5XB0 according to EN 60721-3-6 spray acc. to EN 60068-2-52
output signal module (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
2 relay outputs according to EN 60721-3-6
Accessories See SIMATIC SM 1226 Usage in industrial process
fail-safe relay output signal module, technology
page 3/168
- Against chemically active Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B (excluding
process, measuring and control trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of
EN 60721-3-3 class 3C4
permissible); level LC3 (salt spray)
and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must
environmental conditions acc. to remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life
• Qualification and Performance of Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6EP1332-1SH71 Article number 6EP1332-1SH71
Product S7-1200 PM1207 Product S7-1200 PM1207
Power supply, type 24 V/2.5 A Power supply, type 24 V/2.5 A
Current range 0 ... 2.5 A Approvals
3 supplied active power typical
short-term overload current
60 W CE mark
UL/cUL (CSA) approval
Yes
cULus-Listed (UL 508, CSA C22.2
• on short-circuiting during 6A No. 107.1), File E197259;
the start-up typical cURus-Recognized (UL 60950-1,
CSA C22.2 No. 60950-1)
• at short-circuit during 6A File E151273
operation typical
Explosion protection ATEX (EX) II 3G Ex nA II T4;
duration of overloading capability cULus (ISA 12.12.01, CSA C22.2
for excess current No.213) Class I, Div. 2, Group ABCD,
• on short-circuiting during 100 ms T4, File E330455
the start-up certificate of suitability NEC Class 2 No
• at short-circuit during operation 100 ms FM approval Class I, Div. 2, Group ABCD, T4
Parallel switching for enhanced Yes CB approval Yes
performance
certificate of suitability EAC approval Yes
Numbers of parallel switchable units 2
for enhanced performance Marine approval ABS, BV, DNV GL, LRS, NK
Efficiency EMC
Efficiency at Uout rated, Iout rated, 83 % Emitted interference EN 55022 Class B
approx. Supply harmonics limitation not applicable
Power loss at Uout rated, Iout rated, 12 W Noise immunity EN 61000-6-2
approx. environmental conditions
Closed-loop control ambient temperature
Dynamic mains compensation 0.3 % • during operation 0 ... 60 °C
(Uin rated ±15 %), max.
- Note with natural convection
Dynamic load smoothing 3%
(Iout: 50/100/50 %), Uout ± typ. • during transport -40 ... +85 °C
Load step setting time 50 to 100%, typ. 5 ms • during storage -40 ... +85 °C
Load step setting time 100 to 50%, typ. 5 ms Humidity class according to Climate class 3K3, 5 … 95%
EN 60721 no condensation
setting time maximum 5 ms
Mechanics
Protection and monitoring
Connection technology screw-type terminals
Output overvoltage protection < 33 V
Connections
Current limitation, typ. 2.65 A
• Supply input L, N, PE: 1 screw terminal each
property of the output short-circuit Yes for 0.5 ... 2.5 mm²
proof
• Output L+, M: 2 screw terminals each
Short-circuit protection Constant current characteristic for 0.5 ... 2.5 mm²
enduring short circuit current RMS • Auxiliary -
value
width of the enclosure 70 mm
• typical 2.7 A
height of the enclosure 100 mm
Overload/short-circuit indicator -
depth of the enclosure 75 mm
Safety
required spacing
Primary/secondary isolation Yes
• top 20 mm
galvanic isolation Safety extra-low output voltage Uout
acc. to EN 60950-1 and EN 50178 • bottom 20 mm
Protection class Class I • left 0 mm
leakage current • right 0 mm
• maximum 3.5 mA Weight, approx. 0.3 kg
Degree of protection (EN 60529) IP20 product feature of the enclosure Yes
housing can be lined up
Installation Snaps onto DIN rail EN 60715
35x7.5/15, wall mounting
MTBF at 40 °C 1 492 537 h
other information Specifications at rated input voltage
and ambient temperature +25 °C
(unless otherwise specified)
■ Overview
• Stabilized power supply for SIPLUS S7-1200
• In the S7-1200 design
• Input 120/230 V AC, output 24 V DC, 2.5 A
(derating: 1.5 A above 60 °C)
Note: 3
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
3
Article No. based on 6EP1332-1SH71
Input 120/230 V AC,
output 24 V DC, 2.5 A; Input voltage, nominal value 120/230 V AC (auto-switching)
derating from +55 °C to +70 °C • Range 85 … 132 V/176 ... 264 V AC
to 1.2 A output current
Mains buffering > 20 ms (at 93/187 V)
Ambient temperature 6AG1332-1SH71-7AA0
-25 ... +70 °C Line frequency, nominal 50/60 Hz
• Range 47 … 63 Hz
Ambient temperature 6AG1332-1SH71-4AA0
0 ... +60 °C Input current, nominal value 1.2/0.67 A
• Inrush current (25 °C) <13 A
• Recommended circuit-breaker 16 A Charact. B, 10 A Charact. C
Output voltage, nominal value 24 V DC
• Tolerance ± 3%
• Residual ripple < 150 mVpp
• Adjustment No
Output current, nominal value 2.5 A (derating: 1.5 A above 60 °C)
Efficiency at nominal values, approx. 83%
Parallel operation Yes, 2 units
Electronic short-circuit protection Yes, automatic restart
Radio interference suppression Class B
(EN 55022)
Operating display Green LED for "24 V o.k."
Supply-harmonics limitation Not applicable
(EN 61000-3-2)
Degree of protection (EN 60529) IP20
Protection class Class 1
Electric isolation SELV acc. to EN 60950 and EN 50178
Ambient temperature 0 … +60 °C
-40 ... +70 °C
Transport and storage temperature -40 ... +85 °C
Installation DIN rail EN 60715 35x7.5/15
Dimensions (W x H x D) in mm 70 x 100 x 75
Weight, approx. 0.3 kg
Certifications CE
The innovative high-resolution widescreen displays with SIMATIC HMI TP700 Basic 6AV2143-6GB00-0AA0
Keyless
64 000 colors are also suitable for upright installation, and they
can be dimmed down to 100%. The innovative operator Touch screen operation;
interface with improved usability opens up a diverse range of 7" TFT display, 65 536 colors,
options thanks to new controls and graphics. The new USB PROFINET interface
interface enables the connection of keyboard, mouse or SIMATIC HMI KTP900 Basic 6AV2123-2JB03-0AX0
barcode scanner, and supports the simple archiving of data on Key/touch-screen operation;
a USB flash drive as well as the manual backup and restoring 9" TFT display, 65 536 colors,
of the complete panel. PROFINET interface
SIMATIC HMI TP900 Basic 6AV2143-6JB00-0AA0
The integrated Ethernet or RS 485/422 interface Keyless
(version-specific) enables simple connection to the controller.
Touch screen operation;
http://www.siemens.com/basic-panels 9" TFT display, 65 536 colors,
PROFINET interface
SIMATIC HMI KTP1200 Basic 6AV2123-2MB03-0AX0
Key/touch-screen operation;
12" TFT display, 65 536 colors,
PROFINET interface
SIMATIC HMI KTP1200 Basic DP 6AV2123-2MA03-0AX0
Key/touch-screen operation;
12" TFT display, 65 536 colors,
PROFIBUS interface
Starter kits
Starter kit LOGO! + KP300 Basic 6AV2132-0HA00-0AA1
mono PN
Starter kit LOGO! + KTP400 Basic 6AV2132-0KA00-0AA1
Starter kit LOGO! + KTP700 Basic 6AV2132-3GB00-0AA1
Starter kits with a LOGO! consist of:
• the respective SIMATIC HMI
Basic Panel
SIMATIC HMI KP300 Basic
mono PN
SIMATIC HMI KTP400 Basic
SIMATIC HMI KTP700 Basic
• LOGO! 12/24 RCE
• LOGO! POWER 24 V 1.3 A
• LOGO! SOFT COMFORT V7
• WINCC BASIC (TIA Portal)
• Ethernet CAT5 cable, 2 m
Documentation
Additional information on the http://support.automation.
manual for the Basic Panels is siemens.com
available on the Internet at:
Accessories See Catalog ST 80 / ST PC or
Industry Mall
■ Technical specifications
Article number 6AG1123-2DB03-2AX0 6AG1123-2GB03-2AX0 6AG1123-2GA03-2AX0
Based on 6AV2123-2DB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2GA03-0AX0
SIPLUS HMI KTP400 BASIC SIPLUS HMI KTP700 BASIC SIPLUS HMI KTP700 BASIC DP
Ambient conditions
Suited for indoor use Yes Yes
Suited for outdoor use No No
Ambient temperature during
operation
• Operation (vertical installation)
- For vertical installation, min. -20 °C; = Tmin -20 °C -20 °C; = Tmin
- For vertical installation, max. 60 °C; = Tmax 50 °C 50 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning when condensation
max. condensation conditions) condensation conditions) present), vertical mounting position
■ Technical specifications
Article number 6AG1123-2DB03-2AX0 6AG1123-2GB03-2AX0 6AG1123-2GA03-2AX0
Based on 6AV2123-2DB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2GA03-0AX0
SIPLUS HMI KTP400 BASIC SIPLUS HMI KTP700 BASIC SIPLUS HMI KTP700 BASIC DP
Resistance
3 Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful gas (excluding trichlorethylene; harmful gas (excluding trichlorethylene; harmful gas
systems acc. to ANSI/ISA-71.04 concentrations up to the limits of concentrations up to the limits of concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil) level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1123-2JB03-2AX0 6AG1123-2MB03-2AX0 6AG1123-2MA03-2AX0
Based on 6AV2123-2JB03-0AX0 6AV2123-2MB03-0AX0 6AV2123-2MA03-0AX0
SIPLUS HMI KTP900 BASIC SIPLUS HMI KTP1200 BASIC SIPLUS HMI KTP1200 BASIC DP
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
3
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation / frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning in bedewed state), (no commissioning when condensation
max. condensation conditions) horizontal installation present), vertical mounting position
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1647-0AH11-2AX0 6AG1647-0AA11-2AX0
Based on 6AV6647-0AH11-3AX0 6AV6647-0AA11-3AX0
SIPLUS HMI KP300 BASIC MONO PN 3,6" SIPLUS KTP400 BASIC MONO PN 3,8"
Ambient conditions
Suited for indoor use
Suited for outdoor use
Yes
No
Yes
No
3
Ambient temperature during
operation
• Operation (vertical installation)
- For vertical installation, min. -25 °C -10 °C
- For vertical installation, max. 60 °C 60 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over * The supplied plug covers must remain in place over
environmental conditions acc. to the unused interfaces during operation! the unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0
Based on 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIPLUS HMI KTP400 SIPLUS HMI TP700 SIPLUS HMI TP900 SIPLUS HMI TP1200
COMFORT COMFORT COMFORT COMFORT
Ambient conditions
Suited for indoor use Yes Yes Yes Yes
3
Suited for outdoor use No No No No
Ambient temperature
during operation
• Operation (vertical installation)
- For vertical installation, min. 0 °C; = Tmin 0 °C; = Tmin 0 °C; = Tmin 0 °C; = Tmin
- For vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt permissible); level LC3 (salt
spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil) spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
■ Technical specifications
Article number 6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0
Based on 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIPLUS HMI KTP400 SIPLUS HMI TP700 SIPLUS HMI TP900 SIPLUS HMI TP1200
COMFORT COMFORT COMFORT COMFORT
3 Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1124-1DC01- 6AG1124-1GC01- 6AG1124-1JC01- 6AG1124-1MC01- 6AG1124-1QC02-
4AX0 4AX0 4AX0 4AX0 4AX1
Based on 6AV2124-1DC01- 6AV2124-1GC01- 6AV2124-1JC01-0AX0 6AV2124-1MC01- 6AV2124-1QC02-
0AX0 0AX0 0AX0 0AX1
SIPLUS HMI KP400
COMFORT
SIPLUS HMI KP700
COMFORT
SIPLUS HMI KP900
COMFORT
SIPLUS HMI KP1200
COMFORT
SIPLUS HMI KP1500
Comfort 3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold
according to EN 60721-3-6 and fungal spores and fungal spores and fungal spores and fungal spores and fungal spores
(excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna);
Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3
according to EN 60721-3-6 (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt
spray acc. to spray acc. to spray acc. to spray acc. to spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl.
according to EN 60721-3-6 sand, dust; * sand, dust; * sand, dust; * sand, dust; * sand, dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding (excluding (excluding (excluding (excluding
trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group
process, measuring and control A/B (excluding A/B (excluding A/B (excluding A/B (excluding A/B (excluding
systems acc. to ANSI/ISA-71.04 trichlorethylene; harmful trichlorethylene; harmful trichlorethylene; harmful trichlorethylene; harmful trichlorethylene; harmful
gas concentrations gas concentrations gas concentrations gas concentrations gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class
3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible);
level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray)
and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug * The supplied plug * The supplied plug * The supplied plug * The supplied plug
environmental conditions acc. to covers must remain in covers must remain in covers must remain in covers must remain in covers must remain in
EN 60721, EN 60654-4 and place over the unused place over the unused place over the unused place over the unused place over the unused
ANSI/ISA-71.04 interfaces during interfaces during interfaces during interfaces during interfaces during
operation! operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of
MIL-I-46058C, Amendment 7 coating possible coating possible coating possible coating possible coating possible
during service life during service life during service life during service life during service life
• Qualification and Performance of Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal
Electrical Insulating Compound for coating, Class A coating, Class A coating, Class A coating, Class A coating, Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1124-0QC02-4AX1 6AG1124-0UC02-4AX1 6AG1124-0XC02-4AX1
Based on 6AV2124-0QC02-0AX1 6AV2124-0UC02-0AX1 6AV2124-0XC02-0AX1
SIPLUS HMI TP1500 Comfort SIPLUS HMI TP1900 Comfort SIPLUS HMI TP2200 Comfort
Altitude during operation relating to
3 sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 080 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax - 20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
• SIMATIC S7-1200 + KTP400 Basic Starter Kit; SIMATIC S7-1200 + KTP400 Basic 6AV6651-7KA02-3AA4
Starter Kit
Consisting of:
CPU 1212C AC/DC/relay, HMI KTP400 Basic, input simulator, Consisting of:
STEP 7 Basic, manual CD, SIMATIC OPC UA S7-1200 Basic CPU 1212C AC/DC/relay,
HMI KTP400 Basic, input simulator,
Runtime license, Systainer STEP 7 Basic, manual CD,
• SIMATIC S7-1200 + KTP700 Basic Starter Kit; SIMATIC OPC UA S7-1200 Basic
Consisting of: Runtime license, Systainer
CPU 1212C AC/DC/relay, HMI KTP700 Basic, input simulator, SIMATIC S7-1200 + KTP700 Basic 6AV6651-7DA02-3AA4
STEP 7 Basic, manual CD, SIMATIC OPC UA S7-1200 Basic Starter Kit
Runtime license, Systainer Consisting of:
• SIMATIC S7-1200 Fail-Safe Starter Kit CPU 1212C AC/DC/relay,
- With CPU 1212 FC DC/DC/relay; HMI KTP700 Basic, input simulator,
STEP 7 Basic, manual CD,
also includes: SIMATIC OPC UA S7-1200 Basic
F-digital input SM 1226 16 x 24 V DC, Runtime license, Systainer
F-digital output SM 1226 4 x 24 V DC, input simulator, SIMATIC S7-1200 Fail-Safe Starter
STEP 7 Basic and STEP 7 Safety Basic V16, SIMATIC OPC Kit
UA S7-1200 Basic, info material; in Systainer
- With CPU 1214 FC DC/DC/relay; With CPU 1212 FC DC/DC/relay; 6ES7212-1HF41-4YB1
also includes:
also includes: F-digital input SM 1226
F-digital input SM 1226 16 x 24 V DC, 16 x 24 V DC,
F-digital output SM 1226 4 x 24 V DC, input simulator, F-digital output SM 1226
STEP 7 Safety Basic, SIMATIC OPC UA S7-1200 Basic, 4 x 24 V DC, input simulator,
info material; in Systainer STEP 7 Basic and
STEP 7 Safety Basic V16,
SIMATIC OPC UA S7-1200 Basic,
info material; in Systainer
With CPU 1214 FC DC/DC/relay; 6ES7212-1HF42-4YB1
also includes:
F-digital input SM 1226
16 x 24 V DC,
F-digital output SM 1226
4 x 24 V DC, input simulator,
STEP 7 Safety Basic,
SIMATIC OPC UA S7-1200 Basic,
info material; in Systainer
■ More information
The CANopen bus can be configured via any commercially
available CANopen configuration tool. HMS Industrial Networks
Note also supplies suitable "CM CANopen Configuration Studio"
The CM CANopen module is an HMS Industrial Networks software with the product. The configuration is saved directly on
product and can only be obtained through HMS. the module by means of a USB connection. Routing via
PROFIBUS/PROFINET is not possible.
The following description contains information on
supplementary products that are manufactured and marketed, Preprogrammed function blocks are available for easier PLC
not by Siemens, but by third-parties outside the Siemens group programming in the TIA Portal.
("external companies"). These external companies organize the For further information, please contact HMS Industrial Networks
manufacture, sale and delivery of their products independently. directly:
Their own terms and conditions of business and delivery apply.
http://www.ixxat.com/cm-canopen
Responsibility for these supplementary products and for the
associated information presented here rests exclusively with Ordering and Support
the respective external company. Unless compulsory by law,
Siemens assumes no liability and makes no guarantee for Please note that ordering and support for the module are
supplemental products of external companies. Please refer also exclusively carried out via HMS Industrial Networks. Please
to the note on "Exemption from liability/Use of hyperlinks" contact HMS Industrial Networks directly should you have any
(see "More information"). questions concerning this module. The relevant contact details
can be found on the Internet at
Overview
http://www.ixxat.com/cm-canopen
An interface module is available for operating the
SIMATIC S7-1200 on CANopen. It can be used together with Exemption from liability/Use of hyperlinks
system and IO components of the S7-1200 automation system. Siemens has prepared this description with great care. It is not
CiA and CANopen are registered Community Trademarks of possible, however, for Siemens to verify that the data supplied
CAN in Automation e.V. by external companies is complete, correct or up to date.
The possibility that individual items of information might be
incorrect, incomplete, or not up-to-date cannot therefore be
■ Application ruled out. Unless compulsory by law, Siemens accepts no
CANopen is a widely used industrial bus system and can be liability for the usability of the data or of the product for
used for a variety of different applications. The module allows the user per se.
simple and cost-effective connection of CANopen applications This article contains third-party Web addresses. Siemens is
to SIMATIC. not responsible for the contents of these Web sites, nor does
• Control of hydraulic valves/axes in vehicles Siemens adopt these Web sites and their contents, as Siemens
does not control the presented information and cannot be held
• Control of motors in packaging machines or conveyors
responsible for the content and information they contain.
• Capturing of angular encoder positions in wind turbines You therefore use these links at your own risk.
• Capturing of control devices on machines, e.g. joysticks
• Capturing the measured data of path encoders, inclinometers
or angular encoders, e.g. for tower cranes and gantry cranes
Siemens ST 70 · 2021
© Siemens 2021
■ Overview
Integrated technology
• Motion Control integrated without additional modules:
- Standardized blocks (PLCopen) for connection of analog
and PROFIdrive-capable drives
- The Motion Control functionality supports speed-controlled
axes, positioning axes, relative synchronous operation
(synchronizing without specification of the synchronized
position), as well as external encoders, output cams and
4 probes.
- Extended Motion Control functions such as absolute
synchronous operation (synchronizing with specification
of the synchronized position), camming and functions for
controlling kinematics are also integrated in the technology
CPUs.
• Comprehensive trace functions for all CPU tags for real-time
diagnostics and sporadic error detection;
With its extended ambient conditions, the SIMATIC S7-1500 can for effective commissioning and quick optimization of drives
be used almost anywhere. Many PLCs can be operated in a and controls
temperature range from -25°C to +60°C and at altitudes up to • Comprehensive control functionalities:
5,000 m as standard. A wide range of SIPLUS PLCs is available e.g. easily configurable blocks for automatic optimization
for requirements beyond this. of the control parameters for optimum control quality
The SIMATIC S7-1500 is • Additional functions through available technology modules:
e.g. high-speed counting, position detection, or measurement
• a modular, scalable, and universally usable system in functions for signals up to 1 MHz
IP20 degree of protection
• the system solution for a variety of automation applications in Safety Integrated
discrete automation • Protection of personnel and machinery – within the framework
• maximum performance combined with excellent usability of an integrated complete system
• configurable in the Totally Integrated Automation Portal with • Fail-safe SIMATIC S7-1500(T)F Controllers for processing
STEP 7 Professional V12 or higher standard and safety programs on the same controller.
The fail-safe and standard user programs are created in the
Performance TIA Portal with the same editors; fail-safe data, for example,
• Increase in performance through can therefore be evaluated like standard data in the standard
- Faster command execution user program. Due to this integration the system benefits and
- Language extensions the comprehensive functionality of SIMATIC are also available
- New data types for fail-safe applications.
- Faster backplane bus
- Optimized code generation
• Powerful communication:
- PROFINET IO (2-port switch) as standard interface;
from CPU 1515-2 PN, one or more additional integrated
PROFINET interfaces, e.g. for network separation, for
connecting further PROFINET devices or for high-speed
communication as an I-Device
- OPC UA server (data access) and client as runtime option
for the easy connection of SIMATIC S7-1500 to non-Siemens
devices/systems
- Expandable with communications modules for bus systems
and point-to-point connection
■ Overview
Redundant systems
Primary Backup
Sync 4
1-Ring
ET 200SP ET 200MP
Primary Backup
Sync
1-Ring
ET 200SP ET 200MP
■ Overview
Security Integrated Integrated system diagnostics
• Password-based know-how protection against unauthorized • Integrated system diagnostics for CPUs, activated by default:
read-out and modification of program blocks - Consistent plain text display of system diagnostic
• Copy protection for greater protection against unauthorized information in the display, TIA Portal, HMI, and web server,
copying of program blocks: even for drive messages. Messages are updated even
With copy protection, individual blocks on the SIMATIC if the CPU is in STOP state.
Memory Card can be tied to its serial number so that the block - System diagnostics integrated in the CPU firmware.
can only be run if the configured memory card is inserted into Configuration by user not required. The diagnostics
4 the CPU.
• Rights concept with four different authorization levels:
is automatically updated on configuration changes.
Support of SIMATIC ProDiag S7-1500
Different access rights can be assigned to various user • ProDiag is a concept for the easy creation of machine and
groups. The new protection level 4 makes it possible to also plant diagnostics It increases availability and supports with
restrict communication to HMI devices. fault analysis and elimination on-site.
• Improved manipulation protection:
Changed or unauthorized transfers of engineering data are Datalog (archives) and recipes
detected by the controller. • SIMATIC Memory Card:
• For use of an Ethernet CP (CP 1543-1): - Plug-in load memory
- Additional access protection by means of a firewall - Permits firmware updates
- Establishment of secure VPN connections - Storage option for STEP 7 projects (including comments
and symbols), additional documentation, or csv/ASCII files
Design and handling (for recipes and archives)
• CPUs with display for plain text information (display simulator - Easy access to plant-relevant operating data and
tool on the Internet): configuration data with Office tools via the SD card reader
- Information about article numbers, firmware version, and the (two-way data exchange from and to the PLC)
serial number of all connected modules can be displayed • Integrated web server:
- Setting the IP address of the CPU and additional network - Easy access to plant-relevant operating data and
settings possible directly on site, without programming configuration data, Motion Control diagnostics and display
device on the display of trace recordings via a web browser
- Display of occurring error messages directly as plain text
message, meaning reduction in downtime Approvals
• Uniform front connectors for all modules and integrated The SIMATIC S7-1500 complies with the following national
potential bridges for flexible potential group formation simplify and international standards:
stock keeping and reduce wiring effort • cULus approval
• Integrated DIN rail in the S7-1500 mounting rail: • cULus HazLoc approval
quick and easy installation of additional components such as
miniature circuit breakers, relays, etc. • FM approval
• Central expansion with signal modules: • ATEX approval (only for 24 V; not for 230 V)
for flexible adaptation to any application • CE
• System cabling for digital signal modules: • RCM (formerly C-Tick)
for fast and clearly arranged connecting to sensors and • KCC
actuators in the field and simple wiring inside the control
cabinet • IECEx (24 V only; not for 230 V)
• Power supply: • EN 61000-6-4
- Load power supply modules (PMs) for supplying the module • EN 60068-2-1/-2/-6/-14/-27/-30/-32
with 24 V • EN 61131-2
- Power supply modules to supply power to the internal
module electronics via the backplane bus You can find the marine approvals available for the S7-1500 on
- System power supply modules for retentively storing the Internet (SIMATIC Customer Support):
the entire work memory on the controller http://www.siemens.com/automation/support
• Distributed expansion:
- Use of up to 30 signal modules, communication modules, The S7-1500 system is also suitable for operating at elevations
and technology modules via the PROFINET interface module up to 5000 m. You can find a list of all currently approved
IM 155-5 for the ET 200MP I/O system modules here:
- No difference in terms of handling and system functions https://support.industry.siemens.com/cs/ww/en/view/109763260
in central and distributed operation
■ Technical specifications
General technical specifications SIMATIC S7-1500 General technical specifications SIPLUS S7-1500
Degree of protection IP20 acc. to IEC 60 529 Ambient temperature range -40/-25/-20 ... +55/60/70 °C
Ambient temperature Conformal coating Coating of the printed circuit boards
• Horizontal installation 0...60 °C (display: at an operating and the electronic components
temperature of typ. 50 °C, the display Technical specifications The technical data of the standard
is switched off.) product applies except for the
• Vertical installation 0... 40 °C (display: at an operating ambient conditions.
temperature of typ. 40 °C, the display
Relative humidity
is switched off.)
10 %...95 %, no condensation
Ambient conditions
Extended range of environmental
4
conditions
Atmospheric pressure From 1080 to 795 hPa • with reference to ambient Tmin ... Tmax at
(corresponds to an altitude temperature, air pressure 1080 hPa ... 795 hPa
of -1000 to +2000 m) and altitude (-1000 m ... +2000 m) //
Insulation Tmin ... (Tmax - 10K) at
• < 50 V 707 V DC test voltage (type test) 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
• < 150 V 2200 V DC test voltage Tmin ... (Tmax - 20K) at
• < 250 V 2500 V DC test voltage 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Electromagnetic compatibility Requirements of the EMC directive;
interference immunity according to • At cold restart, min. 0° C
IEC 61000-6-2 Relative humidity
• Pulse-shaped disturbance variables Test according to: • with condensation, max. 100 %; RH incl. bedewing/frost
Electrostatic discharge according to (no commissioning in bedewed state)
IEC 61000-4-2,
burst pulses according to Resistance
IEC 61000-4-4, • to biologically active Yes; Class 3B2 mold and fungal
energy single pulse (surge) substances/compliance with spores (except fauna); the supplied
according to IEC 61000-4-5, EN 60721-3-3 plug covers must remain in place on
• Sinusoidal disturbance variables Test according to: the unused interfaces during
HF irradiation according to operation.
IEC 61000-4-3, • to chemically active Yes; Class 3C4 (RH < 75%) incl. salt
HF decoupling according to substances/compliance with spray in accordance with
IEC 61000-4-6 EN 60721-3-3 EN 60068-2-52 (severity 3);
Requirements of the EMC directive; the supplied plug covers must remain
interference emission according to in place on the unused interfaces
EN 61000-6-4 during operation.
• Emission of radio frequency Interference emission according to • to mechanically active substances, Yes; Class 3S4 incl. sand, dust; the
interference 61000-6-4 compliance with EN 60721-3-3 supplied plug covers must remain in
place on unused interfaces during
Interference emission of operation.
electromagnetic fields according to
EN 61000-6-4
Mechanical stress
• Vibrations Testing according to EN 60068-2-6
Tested with:
5 Hz ≤ f ≤ 8.4 Hz,
constant amplitude 7 mm;
9 Hz ≤ f ≤ 150 Hz, constant
acceleration 2 g;
duration of vibration: 10 frequency
passes per axis in each direction of
the 3 mutually perpendicular axes
• Shock Testing according to EN 60068-2-27
Tested with:
Half-wave:
strength of shock 15 g peak value,
11 ms duration;
shock direction: 3 shocks each
in ± direction in each of the
3 mutually vertical axes
• Entry-level CPU in the S7-1500 Controller product range • The CPU for applications with medium requirements for
• Suitable for applications with medium requirements for program/data storage in the S7-1500 Controller product range
program scope and processing speed • Medium to high processing speed for binary and
• Used as central PLC in production lines with central and floating-point arithmetic
distributed I/O • Used as central PLC in production lines with central and
• PROFINET IO IRT interface with 2-port switch distributed I/O
• PROFINET IO controller for operating distributed I/O on • PROFINET IO IRT interface with 2-port switch
PROFINET • PROFINET IO controller for operating distributed I/O on
• PROFINET I-Device for connecting the CPU as an intelligent PROFINET
PROFINET device under a SIMATIC or non-Siemens • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET IO controller PROFINET device under a SIMATIC or non-Siemens
• OPC UA Server and Client as runtime option for the easy PROFINET IO controller
connection of SIMATIC S7-1500 to non-Siemens • OPC UA Server and Client as runtime option for the easy
devices/systems with the functions: connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Data Access devices/systems with the functions:
- OPC UA Security - OPC UA Data Access
- OPC UA Methods Call, Support - OPC UA Security
- OPC UA Companion Specifications - OPC UA Methods Call
- OPC UA Alarms & Conditions - Support of OPC UA Companion specifications
• Central and distributed isochronous mode - OPC UA Alarms & Conditions
• Integrated Motion Control functionalities for controlling speed- • Central and distributed isochronous mode
controlled and positioning axes, support for external • Integrated Motion Control functionalities for controlling speed-
encoders, output cams/cam tracks and probes controlled and positioning axes, support for external
• Integrated web server for diagnostics with the option of encoders, output cams/cam tracks and probes
creating user-defined web pages • Integrated web server for diagnostics with the option of
creating user-defined web pages
Note:
Note:
SIMATIC Memory Card required for operation of the CPU
SIMATIC Memory Card required for operation of the CPU
• The CPU for applications with medium to high requirements • The CPU with a large program and data memory in the
for program/data storage in the S7-1500 Controller product S7-1500 Controller product range for applications with high
range requirements regarding program scope and networking.
• Medium to high processing speed for binary and floating- • High processing speed for binary and floating-point arithmetic
point arithmetic • Used as central PLC in production lines with central and
• Used as central PLC in production lines with central and distributed I/O
distributed I/O • PROFINET IO IRT interface with 2-port switch
• PROFINET IO IRT interface with 2-port switch • PROFINET IO controller for operating distributed I/O on
• PROFINET IO controller for operating distributed I/O on PROFINET.
PROFINET • PROFINET I-Device for connecting the CPU as an intelligent
• PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens
PROFINET device under a SIMATIC or non-Siemens PROFINET IO controller
PROFINET IO controller • Additional PROFINET interface with separate IP address for
• Additional PROFINET interface with separate IP address for network separation, for connecting further PROFINET IO RT
network separation, for connecting further PROFINET IO RT devices, or for high-speed communication as an I-Device
devices, or for high-speed communication as an I-Device • PROFIBUS DP master interface
• OPC UA Server and Client as runtime option for the easy • UA server and client as runtime option for easy connection of
connection of SIMATIC S7-1500 to non-Siemens the SIMATIC S7-1500 to non-Siemens devices/systems with
devices/systems with the functions: the functions:
- OPC UA Data Access - OPC UA Data Access
- OPC UA Security - OPC UA Security
- OPC UA Methods Call - OPC UA Methods Call
- Support of OPC UA Companion specifications - Support of OPC UA Companion specifications
- OPC UA Alarms & Conditions - OPC UA Alarms & Conditions
• Central and distributed isochronous mode • Central and distributed isochronous mode on PROFIBUS and
• Integrated Motion Control functionalities for controlling speed- PROFINET
controlled and positioning axes, precise position gearing • Integrated Motion Control functionalities for controlling
between axes, support for external encoders, output speed-controlled and positioning axes, support for external
cams/cam tracks and measuring inputs encoders, output cams/cam tracks and measuring inputs
• Integrated web server for diagnostics with the option of • Integrated web server for diagnostics with the option of
creating user-defined web pages creating user-defined web pages
Note: Note:
SIMATIC Memory Card required for operation of the CPU SIMATIC Memory Card required for operation of the CPU
• The CPU with a very large program and data memory in the • The CPU with a very large program and data memory in the
S7-1500 Controller product range for applications with high S7-1500 Controller product range for demanding applications
requirements regarding program scope and networking. with extremely high requirements regarding program scope,
• High processing speed for binary and floating-point arithmetic performance and networking
• For cross-industry automation tasks in series machine, special • Extremely high processing speed for binary and floating-point
machine and plant construction arithmetic
• Used as central PLC in production lines with central and • For cross-industry automation tasks in series machine,
distributed I/O special machine and plant construction
• PROFINET IO IRT interface with 2-port switch • Used as central PLC in production lines with central and
distributed I/O
• PROFINET IO controller for operating distributed I/O on
PROFINET. • PROFINET IO IRT interface with 2-port switch
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO controller for operating distributed I/O on
PROFINET device under a SIMATIC or non-Siemens PROFINET.
PROFINET IO controller • PROFINET I-Device for connecting the CPU as an intelligent
• Additional PROFINET interface with separate IP address for PROFINET device under a SIMATIC or non-Siemens
network separation, for connecting further PROFINET IO RT PROFINET IO controller
devices, or for high-speed communication as an I-Device • Two additional PROFINET interfaces with separate
• PROFIBUS DP master interface IP address; for network separation. The PROFINET interface
X2 can be used for connecting additional PROFINET IO RT
• OPC UA Server and Client as runtime option for the easy devices or for fast communication as an I-Device. The
connection of SIMATIC S7-1500 to non-Siemens PROFINET interface X3 facilitates data transfer at a speed of
devices/systems with the functions: 1 Gbps.
- OPC UA Data Access
- OPC UA Security • PROFIBUS DP master interface
- OPC UA Methods Call • OPC UA Server and Client as runtime option for the easy
- Support of OPC UA Companion specifications connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Alarms & Conditions devices/systems with the functions:
• Central and distributed isochronous mode on PROFIBUS and - OPC UA Data Access
PROFINET - OPC UA Security
- OPC UA Methods Call
• Integrated Motion Control functionalities for controlling - Support of OPC UA Companion specifications
speed-controlled and positioning axes, support for external - OPC UA Alarms & Conditions
encoders, precise position gearing between axes, output
cams/cam tracks and probes • Central and distributed isochronous mode on PROFIBUS and
PROFINET
• Integrated web server for diagnostics with the option of
creating user-defined web pages • Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes, support for external
Note: encoders, precise position gearing between axes, output
SIMATIC Memory Card required for operation of the CPU. cams/cam tracks and probes
• Integrated web server for diagnostics with the option of
creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU
4
Open Development Kit V2.5 for 6ES7806-2CD03-0YG0 SIMATIC Target + ODK 1500S 6ES7823-1BE14-0YA0
support in developing high-level bundle
language applications for
SIMATIC S7-1500 Advanced Download incl. license key 1)
Controllers; software download Email address required for delivery
including license key
(floating license) 1) SIMATIC Manual Collection 6ES7998-8XC01-8YE0
Email address required for delivery Electronic manuals on DVD,
Open Development Kit for 6ES7806-2CD03-0YK0 multi-language:
support in developing high-level LOGO!, SIMADYN,
language applications for SIMATIC bus components,
SIMATIC S7-1500 Advanced SIMATIC C7,
Controllers; upgrade to V2.5 for SIMATIC Distributed I/O,
existing installations as of V1.0; SIMATIC HMI,
software download including SIMATIC sensors, SIMATIC NET,
license key (floating license) 1) SIMATIC PC-based Automation,
SIMATIC PCS 7, SIMATIC PG/PC,
Email address required for delivery SIMATIC S7, SIMATIC software,
SIMATIC TDC
SIMATIC Manual Collection 6ES7998-8XC01-8YE2
update service for 1 year
Current Manual Collection DVD and
the three subsequent updates
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
General information
Product type designation CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN CPU 1516-3 PN/DP
Engineering with
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V15 V17 (FW V2.9) / V15 V17 (FW V2.9) / V16 V17 (FW V2.9) / V16
integrated from version (FW V2.5) or higher; (FW V2.5) or higher; (FW V2.8) or higher; (FW V2.8) or higher;
with older TIA Portal with older TIA Portal with older TIA Portal with older TIA Portal
versions configurable as versions configurable as versions configurable as versions configurable as
6ES7511-1AK01-0AB0 6ES7513-1AL01-0AB0 6ES7515-2AM01-0AB0 6ES7516-3AN01-0AB0
Display
Screen diagonal [cm] 3.45 cm 3.45 cm 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 150 kbyte 300 kbyte 500 kbyte 1 Mbyte
• integrated (for data) 1 Mbyte 1.5 Mbyte 3 Mbyte 5 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte 32 Gbyte 32 Gbyte
max.
CPU processing times
for bit operations, typ. 60 ns 40 ns 30 ns 10 ns
for word operations, typ. 72 ns 48 ns 36 ns 12 ns
for fixed point arithmetic, typ. 96 ns 64 ns 48 ns 16 ns
for floating point arithmetic, typ. 384 ns 256 ns 192 ns 64 ns
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048
4
IEC counter
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
S7 times
• Number 2 048 2 048 2 048 2 048
IEC timer
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in 32 kbyte; All inputs are in 32 kbyte; All inputs are in 32 kbyte; All inputs are in
the process image the process image the process image the process image
• Outputs 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in
the process image the process image the process image the process image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock Hardware clock
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2 2
• integrated switch Yes Yes Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes
• Media redundancy Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes
- Isochronous mode No No
- Direct data exchange
- IRT
No
No
No
No 4
- PROFIenergy Yes; per user program Yes; per user program
- Prioritized startup No No
- Number of connectable 32; In total, up to 32; In total, up to
IO Devices, max. 1 000 distributed I/O devices 1 000 distributed I/O devices
can be connected via AS-i, can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET
- Number of connectable 32 32
IO Devices for RT, max.
- of which in line, max. 32 32
- Number of IO Devices 8; in total across all 8; in total across all
that can be simultaneously interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8
max.
- Updating times The minimum value of the The minimum value of the
update time also depends update time also depends
on communication share set on communication share set
for PROFINET IO, on the for PROFINET IO, on the
number of IO devices, and number of IO devices, and
on the quantity of configured on the quantity of configured
user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes
- Isochronous mode No No
- IRT No No
- PROFIenergy Yes; per user program Yes; per user program
- Prioritized startup No No
- Shared device Yes Yes
- Number of IO Controllers with 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program
3. Interface
Interface types
• RS 485 Yes; X3
• Number of ports 1
Protocols
• PROFIBUS DP master Yes
• PROFIBUS DP slave No
• SIMATIC communication Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to
1 000 distributed I/O devices
can be connected via AS-i,
PROFIBUS or PROFINET
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
Protocols
Number of connections
• Number of connections, max. 96; via integrated interfaces 128; via integrated interfaces 192; via integrated interfaces 256; via integrated interfaces
of the CPU and connected of the CPU and connected of the CPU and connected of the CPU and connected
CPs / CMs CPs / CMs CPs / CMs CPs / CMs
4 Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) only via 1st interface (X1) only via 1st interface (X1) only via 1st interface (X1)
- MRP Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager
according to according to according to according to
IEC 62439-2 Edition 2.0, IEC 62439-2 Edition 2.0, IEC 62439-2 Edition 2.0, IEC 62439-2 Edition 2.0,
MRP Manager; MRP Client MRP Manager; MRP Client MRP Manager; MRP Client MRP Manager; MRP Client
- MRP interconnection, supported Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node
according to according to according to according to
IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP,
bumpless for MRPD bumpless for MRPD bumpless for MRPD bumpless for MRPD
- Number of stations in the ring, 50 50 50 50
max.
SIMATIC communication
• S7 routing Yes Yes Yes Yes
OPC UA
• OPC UA Client Yes Yes Yes Yes
• OPC UA Server Yes; Data access (read, Yes; Data access (read, Yes; Data access (read, Yes; Data access (read,
write, subscribe), method write, subscribe), method write, subscribe), method write, subscribe), method
call, custom address space call, custom address space call, custom address space call, custom address space
• Alarms and Conditions Yes Yes Yes Yes
Supported technology objects
Motion Control Yes; Note: The number of Yes; Note: The number of Yes; Note: The number of Yes; Note: The number of
technology objects affects technology objects affects technology objects affects technology objects affects
the cycle time of the the cycle time of the the cycle time of the the cycle time of the
PLC program; PLC program; PLC program; PLC program;
selection guide via the selection guide via the selection guide via the selection guide via the
TIA Selection Tool TIA Selection Tool TIA Selection Tool TIA Selection Tool
• Number of available Motion Control 800 800 2 400 2 400
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40 40 40
- per positioning axis 80 80 80 80
- per synchronous axis 160 160 160 160
- per external encoder 80 80 80 80
- per output cam 20 20 20 20
- per cam track 160 160 160 160
- per probe 40 40 40 40
Controller
• PID_Compact Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller
with integrated optimization with integrated optimization with integrated optimization with integrated optimization
• PID_3Step Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization for integrated optimization for integrated optimization for integrated optimization for
valves valves valves valves
• PID-Temp Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization for integrated optimization for integrated optimization for integrated optimization for
temperature temperature temperature temperature
Counting and measuring
• High-speed counter Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7515-2AM02-0AB0 6ES7516-3AN02-0AB0
CPU 1511-1PN, 150KB CPU 1513-1 PN, CPU 1515-2 PN, CPU 1516-3 PN/DP,
Program, 1MB Data 300KB Prog., 1,5MB Data 500KB Prog., 3MB Data 1MB Prog., 5MB Data
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation
• horizontal installation, max. 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an
operating temperature of
typically 50 °C, the display is
operating temperature of
typically 50 °C, the display is
operating temperature of
typically 50 °C, the display is
operating temperature of
typically 50 °C, the display is 4
switched off switched off switched off switched off
• vertical installation, min. -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation
• vertical installation, max. 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an
operating temperature of operating temperature of operating temperature of operating temperature of
typically 40 °C, the display is typically 40 °C, the display is typically 40 °C, the display is typically 40 °C, the display is
switched off switched off switched off switched off
Altitude during operation
relating to sea level
• Installation altitude above 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for
sea level, max. installation altitudes installation altitudes installation altitudes installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Configuration
Programming
Programming language
- LAD Yes Yes Yes Yes
- FBD Yes Yes Yes Yes
- STL Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes Yes
protection
• Copy protection Yes Yes Yes Yes
• Block protection Yes Yes Yes Yes
Access protection
• protection of confidential Yes Yes Yes Yes
configuration data
• Password for display Yes Yes Yes Yes
• Protection level: Write protection Yes Yes Yes Yes
• Protection level: Read/write Yes Yes Yes Yes
protection
• Protection level: Complete Yes Yes Yes Yes
protection
Dimensions
Width 35 mm 35 mm 70 mm 70 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 405 g 405 g 830 g 845 g
■ Technical specifications
Article number 6ES7517-3AP00-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
CPU 1517-3 PN/DP, 2MB Prog./8MB CPU 1518-4 PN/DP, 4 MB Prog., 20MB CPU 1518-4 PN/DP MFP + C/C++ RT
Data Data + OPC UA
Memory
Work memory
• integrated (for program) 2 Mbyte 6 Mbyte 6 Mbyte
• integrated (for data) 8 Mbyte 60 Mbyte 60 Mbyte
■ Technical specifications
Article number 6ES7517-3AP00-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
CPU 1517-3 PN/DP, 2MB Prog./8MB CPU 1518-4 PN/DP, 4 MB Prog., 20MB CPU 1518-4 PN/DP MFP + C/C++ RT
Data Data + OPC UA
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes
- Isochronous mode Yes Yes Yes
- Direct data exchange Yes; Requirement: IRT and
isochronous mode (MRPD optional)
Yes; Requirement: IRT and
isochronous mode (MRPD optional)
Yes; Requirement: IRT and
isochronous mode (MRPD optional) 4
- IRT Yes Yes Yes
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup Yes; Max. 32 PROFINET devices Yes; Max. 32 PROFINET devices Yes; Max. 32 PROFINET devices
- Number of connectable IO 512; In total, up to 1 000 distributed I/O 512; In total, up to 1 000 distributed I/O 512; In total, up to 1 000 distributed I/O
Devices, max. devices can be connected via AS-i, devices can be connected via AS-i, devices can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET PROFIBUS or PROFINET
- Of which IO devices with IRT, max. 64 64 64
- Number of connectable IO 512 512 512
Devices for RT, max.
- of which in line, max. 512 512 512
- Number of IO Devices 8; in total across all interfaces 8; in total across all interfaces 8; in total across all interfaces
that can be simultaneously
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8
max.
- Updating times The minimum value of the update time The minimum value of the update time The minimum value of the update time
also depends on communication share also depends on communication share also depends on communication share
set for PROFINET IO, on the number of set for PROFINET IO, on the number of set for PROFINET IO, on the number of
IO devices, and on the quantity of IO devices, and on the quantity of IO devices, and on the quantity of
configured user data configured user data configured user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes
- Isochronous mode No No No
- IRT Yes Yes; Minimum send cycle of 250 µs Yes; Minimum send cycle of 250 µs
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program
- Shared device Yes Yes Yes
- Number of IO Controllers with 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program
2. Interface
Interface types
• RJ 45 (Ethernet) Yes; X2 Yes; X2 Yes; X2
• Number of ports 1 1 1
• integrated switch No No No
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Optionally also encrypted Yes; Optionally also encrypted Yes; Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy No No No
■ Technical specifications
Article number 6ES7517-3AP00-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
CPU 1517-3 PN/DP, 2MB Prog./8MB CPU 1518-4 PN/DP, 4 MB Prog., 20MB CPU 1518-4 PN/DP MFP + C/C++ RT
Data Data + OPC UA
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes
- Isochronous mode No No No
■ Technical specifications
Article number 6ES7517-3AP00-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
CPU 1517-3 PN/DP, 2MB Prog./8MB CPU 1518-4 PN/DP, 4 MB Prog., 20MB CPU 1518-4 PN/DP MFP + C/C++ RT
Data Data + OPC UA
4. Interface
Interface types
• RS 485 Yes; X4 Yes; X4
• Number of ports 1 1
Protocols
• PROFIBUS DP master Yes Yes 4
• PROFIBUS DP slave No No
• SIMATIC communication Yes Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to 1 000 distributed I/O 125; In total, up to 1 000 distributed I/O
devices can be connected via AS-i, devices can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET
Protocols
Number of connections
• Number of connections, max. 320; via integrated interfaces of the 384; via integrated interfaces of the 384; via integrated interfaces of the
CPU and connected CPs / CMs CPU and connected CPs / CMs CPU and connected CPs / CMs
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) only via 1st interface (X1) only via 1st interface (X1)
- MRP Yes; MRP Automanager according to Yes; MRP Automanager according to Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0, IEC 62439-2 Edition 2.0, IEC 62439-2 Edition 2.0,
MRP Manager; MRP Client MRP Manager; MRP Client MRP Manager; MRP Client
- MRP interconnection, supported Yes; as MRP ring node according to Yes; as MRP ring node according to Yes; as MRP ring node according to
IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD 200 ms; For MRP, bumpless for MRPD 200 ms; For MRP, bumpless for MRPD
- Number of stations in the ring, max. 50 50 50
SIMATIC communication
• S7 routing Yes Yes Yes
OPC UA
• OPC UA Client Yes Yes Yes
• OPC UA Server Yes; Data access (read, write, Yes; Data access (read, write, Yes; Data access (read, write,
subscribe), method call, custom subscribe), method call, custom subscribe), method call, custom
address space address space address space
• Alarms and Conditions Yes Yes Yes
Supported technology objects
Motion Control Yes; Note: The number of technology Yes; Note: The number of technology Yes; Note: The number of technology
objects affects the cycle time of the objects affects the cycle time of the objects affects the cycle time of the
PLC program; selection guide via the PLC program; selection guide via the PLC program; selection guide via the
TIA Selection Tool TIA Selection Tool TIA Selection Tool
• Number of available Motion Control 10 240 15 360 15 360
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40 40
- per positioning axis 80 80 80
- per synchronous axis 160 160 160
- per external encoder 80 80 80
- per output cam 20 20 20
- per cam track 160 160 160
- per probe 40 40 40
Controller
• PID_Compact Yes; Universal PID controller with Yes; Universal PID controller with Yes; Universal PID controller with
integrated optimization integrated optimization integrated optimization
• PID_3Step Yes; PID controller with integrated Yes; PID controller with integrated Yes; PID controller with integrated
optimization for valves optimization for valves optimization for valves
• PID-Temp Yes; PID controller with integrated Yes; PID controller with integrated Yes; PID controller with integrated
optimization for temperature optimization for temperature optimization for temperature
Counting and measuring
• High-speed counter Yes Yes Yes
■ Technical specifications
Article number 6ES7517-3AP00-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
CPU 1517-3 PN/DP, 2MB Prog./8MB CPU 1518-4 PN/DP, 4 MB Prog., 20MB CPU 1518-4 PN/DP MFP + C/C++ RT
Data Data + OPC UA
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, at an operating 60 °C; Display: 50 °C, at an operating 60 °C; Display: 50 °C, at an operating
4 temperature of typically 50 °C,
the display is switched off
temperature of typically 50 °C,
the display is switched off
temperature of typically 50 °C,
the display is switched off
• vertical installation, min. 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, at an operating 40 °C; Display: 40 °C, at an operating 40 °C; Display: 40 °C, at an operating
temperature of typically 40 °C, temperature of typically 40 °C, temperature of typically 40 °C,
the display is switched off the display is switched off the display is switched off
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for installation 5 000 m; Restrictions for installation 5 000 m; Restrictions for installation
max. altitudes > 2 000 m, see manual altitudes > 2 000 m, see manual altitudes > 2 000 m, see manual
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- GRAPH Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes
protection
• Copy protection Yes Yes Yes
• Block protection Yes Yes Yes
Access protection
• protection of confidential Yes Yes Yes
configuration data
• Password for display Yes Yes Yes
• Protection level: Write protection Yes Yes Yes
• Protection level: Read/write Yes Yes Yes
protection
• Protection level: Complete Yes Yes Yes
protection
Open Development interfaces
• Size of ODK SO file, max. 9.8 Mbyte
Dimensions
Width 175 mm 175 mm 175 mm
Height 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm
Weights
Weight, approx. 1 978 g 1 988 g 2 117 g
• Entry-level CPU in the S7-1500 Controller product range • The CPU for applications with medium/high requirements for
• Suitable for applications with medium requirements for program/data storage in the S7-1500 Controller product range
program scope and processing speed • High processing speed for binary and floating-point arithmetic
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O
• PROFINET IO IRT interface with 2-port switch • PROFINET IO IRT interface with 2-port switch
• PROFINET IO controller for operating distributed I/O on • PROFINET IO controller for operating distributed I/O on
PROFINET PROFINET
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens PROFINET device under a SIMATIC or non-Siemens
PROFINET I/O controller PROFINET I/O controller
• OPC UA server and client as runtime option for the easy • OPC UA server and client as runtime option for the easy
connection of SIMATIC S7-1500 to non-Siemens connection of SIPLUS S7-1500 to non-Siemens
devices/systems with the functions: devices/systems with the functions:
- OPC UA Data Access - OPC UA Data Access
- OPC UA Security - OPC UA Security
- OPC UA Methods Call, Support - OPC UA Methods Call, Support
- OPC UA Companion Specifications - OPC UA Companion Specifications
• Central and distributed isochronous mode • Central and distributed isochronous mode
• Integrated Motion Control functionalities for controlling speed- • Integrated Motion Control functionalities for controlling speed-
controlled and positioning axes, support for external controlled and positioning axes, support for external
encoders, output cams/cam tracks and probes encoders, output cams/cam tracks and probes
• Integrated web server for diagnostics with the option of • Integrated web server for diagnostics with the option of
creating user-defined web pages creating user-defined web pages
• SIMATIC Memory Card required for operation of the CPU • SIMATIC Memory Card required for operation of the CPU
Note: Note:
SIPLUS extreme products are based on SIMATIC standard SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific respective standard products. SIPLUS extreme-specific
information has been added. information was added.
■ Overview SIPLUS CPU 1516-3 PN/DP ■ Overview SIPLUS CPU 1518-4 PN/DP
• The CPU with large program and data memory in the S7-1500 • The CPU with a very large program and data memory in the
Controller product range for applications with high program S7-1500 Controller product range for demanding applications
scope requirements. with extremely high requirements regarding program scope,
• High processing speed for binary and floating-point arithmetic performance and networking
• Used as central PLC in production lines with central and • Extremely high processing speed for binary and floating-point
distributed I/O arithmetic
• PROFINET IO IRT interface with 2-port switch • For cross-industry automation tasks in series machines,
special machines and plant construction
• Additional PROFINET interface with separate IP address
• Used as central PLC in production lines with central and
• PROFINET IO controller for operating distributed I/O on distributed I/O
PROFINET.
• PROFINET IO IRT interface with 2-port switch
• PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens • Two additional PROFINET interfaces with separate IP address
PROFINET IO controller. • PROFINET IO controller for operating distributed I/O on
• PROFIBUS DP master interface PROFINET.
• Isochronous mode on PROFIBUS and PROFINET • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
• SIMATIC Memory Card required for operation of the CPU PROFINET IO controller.
Note: • PROFIBUS DP master interface
SIPLUS extreme products are based on SIMATIC standard • Isochronous mode on PROFIBUS and PROFINET
products. The contents listed here were taken from the • Integrated Motion Control functionalities for controlling
respective standard products. SIPLUS extreme-specific speed-controlled and positioning axes, support for
information was added. external encoders
• Integrated web server with the option of creating user-defined
web pages
SIMATIC Memory Card required for operation of the CPU
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1511-1AK02-2AB0 6AG1511-1AK02-7AB0 6AG1513-1AL02-2AB0 6AG1513-1AL02-7AB0
Based on 6ES7511-1AK02-0AB0 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7513-1AL02-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
CPU 1511-1 PN CPU 1511-1 PN CPU 1513-1 PN CPU 1513-1 PN
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
■ Technical specifications
Article number 6AG1511-1AK02-2AB0 6AG1511-1AK02-7AB0 6AG1513-1AL02-2AB0 6AG1513-1AL02-7AB0
Based on 6ES7511-1AK02-0AB0 6ES7511-1AK02-0AB0 6ES7513-1AL02-0AB0 6ES7513-1AL02-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
CPU 1511-1 PN CPU 1511-1 PN CPU 1513-1 PN CPU 1513-1 PN
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
■ Technical specifications
Article number 6AG1516-3AN01-2AB0 6AG1516-3AN02-7AB0 6AG1518-4AP00-4AB0 6AG1518-4AX00-4AC0
Based on 6ES7516-3AN01-0AB0 6ES7516-3AN02-0AB0 6ES7518-4AP00-0AB0 6ES7518-4AX00-1AC0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
CPU 1516-3 PN/DP CPU 1516-3 PN/DP CPU 1518-4 PN/DP CPU 1518-4 PN/DP MFP
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems 4
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold, fungal Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding and dry rot spores fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request (excluding fauna) fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); permissible); permissible); permissible);
level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil) level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
• The compact CPU with integral digital and analog inputs and • The compact CPU with integral digital and analog inputs and
outputs in the product spectrum of the S7-1500 Controllers outputs in the product spectrum of the S7-1500 Controllers
• With integrated technological functions, e.g. high-speed • With integrated technological functions, e.g. high-speed
counter (HSC), frequency measurement, period duration counter (HSC), frequency measurement, period duration
measurement or stepper motor control, pulse width measurement or stepper motor control, pulse width
modulation, frequency output modulation, frequency output
• Suitable for applications with medium requirements for • Suitable for applications with medium requirements for
program scope and processing speed program scope and processing speed
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O
• PROFINET IO IRT interface with 2-port switch • PROFINET IO IRT interface with 2-port switch
• PROFINET IO controller for operating distributed I/O on • PROFINET IO controller for operating distributed I/O on
PROFINET PROFINET
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens PROFINET device under a SIMATIC or non-Siemens
PROFINET IO controller PROFINET IO controller
• OPC UA Server and Client as runtime option for the easy • OPC UA Server and Client as runtime option for the easy
connection of SIMATIC S7-1500 to non-Siemens connection of SIMATIC S7-1500 to non-Siemens
devices/systems with the functions: devices/systems with the functions:
- OPC UA Data Access - OPC UA Data Access
- OPC UA Security - OPC UA Security
- OPC UA Methods Call - OPC UA Methods Call
- Support of OPC UA Companion specifications - Support of OPC UA Companion specifications
- OPC UA Alarms & Conditions - OPC UA Alarms & Conditions
• Isochronous mode (distributed) • Isochronous mode (distributed)
• Integrated Motion Control functionalities for controlling • Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes, support for external speed-controlled and positioning axes, support for external
encoders, output cams/cam tracks and probes encoders, output cams/cam tracks and probes
• Integrated web server for diagnostics with the option of • Integrated web server for diagnostics with the option of
creating user-defined web pages creating user-defined web pages
Note: Note:
SIMATIC Memory Card required for operation of the CPU. SIMATIC Memory Card required for operation of the CPU.
■ Technical specifications
Article number 6ES7511-1CK01-0AB0 6ES7512-1CK01-0AB0
CPU 1511C-1 PN, 175 KB Prog, 1 MB Data CPU 1512C-1 PN, 250 KB Prog, 1 MB Data
General information
Product type designation CPU 1511C-1 PN CPU 1512C-1 PN
Engineering with
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA
integrated from version Portal versions configurable as 6ES7511-1CK00-0AB0 Portal versions configurable as 6ES7512-1CK00-0AB0
Display
Screen diagonal [cm] 3.45 cm 3.45 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 175 kbyte 250 kbyte
• integrated (for data) 1 Mbyte 1 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte
max.
■ Technical specifications
Article number 6ES7511-1CK01-0AB0 6ES7512-1CK01-0AB0
CPU 1511C-1 PN, 175 KB Prog, 1 MB Data CPU 1512C-1 PN, 250 KB Prog, 1 MB Data
CPU processing times
for bit operations, typ. 60 ns 48 ns
for word operations, typ. 72 ns 58 ns
for fixed point arithmetic, typ. 96 ns 77 ns
for floating point arithmetic, typ. 384 ns 307 ns
Counters, timers and their
retentivity 4
S7 counter
• Number 2 048 2 048
IEC counter
• Number Any (only limited by the main memory) Any (only limited by the main memory)
S7 times
• Number 2 048 2 048
IEC timer
• Number Any (only limited by the main memory) Any (only limited by the main memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the process image 32 kbyte; All inputs are in the process image
• Outputs 32 kbyte; All outputs are in the process image 32 kbyte; All outputs are in the process image
Time of day
Clock
• Type Hardware clock Hardware clock
Digital inputs
integrated channels (DI) 16 32
Digital outputs
integrated channels (DO) 16 32
Short-circuit protection Yes; electronic/thermal Yes; electronic/thermal
Analog outputs
integrated channels (AO) 2 2
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1
• Number of ports 2 2
• integrated switch Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes
• PROFINET IO Device Yes Yes
• SIMATIC communication Yes Yes
• Open IE communication Yes; Optionally also encrypted Yes; Optionally also encrypted
• Web server Yes Yes
• Media redundancy Yes Yes
■ Technical specifications
Article number 6ES7511-1CK01-0AB0 6ES7512-1CK01-0AB0
CPU 1511C-1 PN, 175 KB Prog, 1 MB Data CPU 1512C-1 PN, 250 KB Prog, 1 MB Data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes
- Isochronous mode Yes Yes
- Direct data exchange Yes; Requirement: IRT and isochronous mode Yes; Requirement: IRT and isochronous mode
4 - IRT
(MRPD optional)
Yes
(MRPD optional)
Yes
- PROFIenergy Yes; per user program Yes; per user program
- Prioritized startup Yes; Max. 32 PROFINET devices Yes; Max. 32 PROFINET devices
- Number of connectable IO 128; In total, up to 256 distributed I/O devices can be 128; In total, up to 256 distributed I/O devices can be
Devices, max. connected via AS-i, PROFIBUS or PROFINET connected via AS-i, PROFIBUS or PROFINET
- Of which IO devices with IRT, max. 64 64
- Number of connectable IO 128 128
Devices for RT, max.
- of which in line, max. 128 128
- Number of IO Devices that can be 8; in total across all interfaces 8; in total across all interfaces
simultaneously
activated/deactivated, max.
- Number of IO Devices per tool, 8 8
max.
- Updating times The minimum value of the update time also depends on The minimum value of the update time also depends on
communication share set for PROFINET IO, on the number communication share set for PROFINET IO, on the number
of IO devices, and on the quantity of configured user data of IO devices, and on the quantity of configured user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes
- Isochronous mode No No
- IRT Yes Yes
- PROFIenergy Yes; per user program Yes; per user program
- Shared device Yes Yes
- Number of IO Controllers with 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program
Protocols
Number of connections
• Number of connections, max. 96; via integrated interfaces of the CPU and 128; via integrated interfaces of the CPU and
connected CPs / CMs connected CPs / CMs
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) only via 1st interface (X1)
- MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, Yes; MRP Automanager according to IEC 62439-2 Edition 2.0,
MRP Manager; MRP Client MRP Manager; MRP Client
- MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD 200 ms; For MRP, bumpless for MRPD
- Number of stations in the ring, 50 50
max.
SIMATIC communication
• S7 routing Yes Yes
OPC UA
• OPC UA Client Yes Yes
• OPC UA Server Yes; Data access (read, write, subscribe), method call, Yes; Data access (read, write, subscribe), method call,
custom address space custom address space
• Alarms and Conditions Yes Yes
■ Technical specifications
Article number 6ES7511-1CK01-0AB0 6ES7512-1CK01-0AB0
CPU 1511C-1 PN, 175 KB Prog, 1 MB Data CPU 1512C-1 PN, 250 KB Prog, 1 MB Data
Supported technology objects
Motion Control Yes; Note: The number of technology objects affects Yes; Note: The number of technology objects affects
the cycle time of the PLC program; selection guide via the cycle time of the PLC program; selection guide via
the TIA Selection Tool the TIA Selection Tool
• Number of available Motion Control 800 800
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40
4
- per positioning axis 80 80
- per synchronous axis 160 160
- per external encoder 80 80
- per output cam 20 20
- per cam track 160 160
- per probe 40 40
Controller
• PID_Compact Yes; Universal PID controller with integrated optimization Yes; Universal PID controller with integrated optimization
• PID_3Step Yes; PID controller with integrated optimization for valves Yes; PID controller with integrated optimization for valves
• PID-Temp Yes; PID controller with integrated optimization for Yes; PID controller with integrated optimization for
temperature temperature
Counting and measuring
• High-speed counter Yes Yes
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -25 °C; No condensation -25 °C; No condensation
• horizontal installation, max. 60 °C; note derating data for onboard I/O in the manual. 60 °C; note derating data for onboard I/O in the manual.
Display: 50 °C, at an operating temperature of typically Display: 50 °C, at an operating temperature of typically
50 °C, the display is switched off 50 °C, the display is switched off
• vertical installation, min. -25 °C; No condensation -25 °C; No condensation
• vertical installation, max. 40 °C; note derating data for onboard I/O in the manual. 40 °C; note derating data for onboard I/O in the manual.
Display: 40 °C, at an operating temperature of typically Display: 40 °C, at an operating temperature of typically
40 °C, the display is switched off 40 °C, the display is switched off
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for installation altitudes > 2 000 m, 5 000 m; Restrictions for installation altitudes > 2 000 m,
max. see manual see manual
Configuration
Programming
Programming language
- LAD Yes Yes
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- GRAPH Yes Yes
Know-how protection
• User program protection/password Yes Yes
protection
• Copy protection Yes Yes
• Block protection Yes Yes
Access protection
• protection of confidential Yes Yes
configuration data
• Password for display Yes Yes
• Protection level: Write protection Yes Yes
• Protection level: Read/write Yes Yes
protection
• Protection level: Complete Yes Yes
protection
Dimensions
Width 85 mm 110 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 1 050 g 1 360 g
• Entry-level CPU in the S7-1500F Controller product range • The CPU for standard and fail-safe applications with
• Can be used for safety functions up to SIL 3 according to medium/high requirements for program/data storage in the
IEC 61508 and up to PLe according to ISO 13849 S7-1500 Controller product range
• Suitable for standard and fail-safe applications with medium • Can be used for safety functions up to SIL 3 according to
requirements for program scope and processing speed IEC 61508 and up to PLe according to ISO 13849
• Used as central PLC in production lines with central and • High processing speed for binary and floating-point arithmetic
distributed I/O • Used as central PLC in production lines with central and
• Supports PROFIsafe in centralized and distributed distributed I/O
configuration • Supports PROFIsafe in centralized and distributed
• PROFINET IO IRT interface with 2-port switch configuration
• PROFINET IO controller for operating distributed I/O on • PROFINET IO IRT interface with 2-port switch
PROFINET • PROFINET IO controller for operating distributed I/O on
• PROFINET I-Device for connecting the CPU as an intelligent PROFINET
PROFINET device under a SIMATIC or non-Siemens • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET IO controller PROFINET device under a SIMATIC or non-Siemens
• Isochronous mode PROFINET IO controller
• Isochronous mode
Note:
Note:
SIMATIC Memory Card required for operation of the CPU
SIMATIC Memory Card required for operation of the CPU
• The CPU for applications with medium to high requirements • The CPU with a large program and data memory in the
for program/data storage in the S7-1500 Controller product S7-1500 Controller product range for fail-safe applications
range with high requirements regarding program scope and
• Can be used for safety functions up to SIL 3 according to networking.
IEC 61508 and up to PLe according to ISO 13849 • Can be used for failsafe functions up to SIL 3 according to
• Medium to high processing speed for binary and floating- IEC 61508 and up to PLe according to ISO 13849.
point arithmetic • High processing speed for binary and floating-point arithmetic
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O.
• Supports PROFIsafe in centralized and distributed • Supports PROFIsafe in centralized and distributed
configurations configuration.
• PROFINET IO IRT interface with 2-port switch • PROFINET IO IRT interface with 2-port switch.
• Additional PROFINET interface with separate IP address • Additional PROFINET interface with separate IP address.
• PROFINET IO controller for operating distributed I/O on • PROFINET IO controller for operating distributed I/O on
PROFINET PROFINET.
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens PROFINET device under a SIMATIC or non-Siemens
PROFINET I/O controller PROFINET IO controller.
• Isochronous mode • PROFIBUS DP master interface.
• Integrated Motion Control functionalities for controlling speed- • Isochronous mode on PROFIBUS and PROFINET.
controlled and positioning axes, support for external encoders • Integrated Motion Control functionalities for controlling
• Integrated web server with the option of creating user-defined speed-controlled and positioning axes, support for external
web pages encoders.
Note: • Integrated web server with the option of creating user-defined
web pages.
SIMATIC Memory Card required for operation of the CPU
Note:
SIMATIC Memory Card required for operation of the CPU
• The CPU with a very large program and data memory in the • The CPU with a very large program and data memory in the
S7-1500 Controller product range for fail-safe applications S7-1500 Controller product range for fail-safe applications with
with high requirements regarding program scope and net- highest requirements regarding program scope and networking.
working. • Can be used for failsafe functions up to SIL 3 according to
• Can be used for safety functions up to SIL 3 according to IEC 61508 and up to PLe according to ISO 13849.
IEC 61508 and up to PLe according to ISO 13849 • Extremely high processing speed for binary and floating-point
• High processing speed for binary and floating-point arithmetic arithmetic.
• For cross-industry automation tasks in series machines, • For cross-industry automation tasks in series machines,
special machines and plant construction special machines and plant construction
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O.
• Supports PROFIsafe in centralized and distributed • Supports PROFIsafe in centralized and distributed
configurations configuration.
• PROFINET IO IRT interface with 2-port switch • PROFINET IO IRT interface with 2-port switch.
• Additional PROFINET interface with separate IP address • Two additional PROFINET interfaces with separate
• PROFINET IO controller for operating distributed I/O on IP addresses.
PROFINET. • PROFINET IO controller for operating distributed I/O on
• PROFINET I-Device for connecting the CPU as an intelligent PROFINET.
PROFINET device under a SIMATIC or non-Siemens • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET IO controller. PROFINET device under a SIMATIC or non-Siemens
• PROFIBUS DP master interface PROFINET IO controller.
• Isochronous mode on PROFIBUS and PROFINET • PROFIBUS DP master interface.
• Integrated Motion Control functionalities for controlling • Isochronous mode on PROFIBUS and PROFINET.
speed-controlled and positioning axes, support for external • Integrated Motion Control functionalities for controlling
encoders, positionally precise gearing between axes speed-controlled and positioning axes, support for external
• Integrated web server with the option of creating user-defined encoders
web pages • Integrated web server with the option of creating user-defined
web pages.
Note:
Note:
SIMATIC Memory Card required for operation of the CPU
SIMATIC Memory Card required for operation of the CPU.
4 Fail-safe CPU,
450 KB work memory for program,
2 GB, also for CPU 1518F-4
PN/DP MFP
6ES7954-8LP03-0AA0
4
Open Development Kit V2.5 for 6ES7806-2CD03-0YG0
STEP 7 Professional V17 support in developing high-level
language applications for
Target system: SIMATIC S7-1500 Advanced
SIMATIC S7-1200, S7-1500, Controllers;
S7-300, S7-400, WinAC software download including
Requirement: license key (floating license) 1)
Windows 10 (64-bit) Email address required for delivery
• Windows 10 Professional Version
1909, 2004, 20H2 Open Development Kit for support 6ES7806-2CD03-0YK0
• Windows 10 Enterprise Version in developing high-level language
1909, 2004, 20H2 applications for SIMATIC S7-1500
• Windows 10 IoT Enterprise 2016 Advanced Controllers;
LTSB upgrade to V2.5 for existing
• Windows 10 IoT Enterprise 2019 installations as of V1.0;
LTSC software download including
Windows Server (64-bit) license key (floating license)1)
• Windows Server 2016 Standard Email address required for delivery
(full installation)
• Windows Server 2019 Standard SIMATIC Target for Simulink V5.0
(full installation) Download incl. license key 1) 6ES7823-1BE04-0YA5
Type of delivery: Email address required for delivery
9 languages: de, en, zh included, fr,
sp, it, ru, jp, kr as download Upgrade of SIMATIC Target 1500S 6ES7823-1BE04-0YE5
for Simulink V2.0...V4.0 to V5.0,
STEP 7 Professional V17, 6ES7822-1AA07-0YA5 download incl. license key 1)
floating license
Email address required for delivery
STEP 7 Professional V17, 6ES7822-1AE07-0YA5
floating license, SIMATIC Target + ODK 1500S 6ES7823-1BE14-0YA0
software download including bundle
license key 1) Download incl. license key 1)
Email address required for delivery Email address required for delivery
STEP 7 Safety Advanced V17 SIMATIC Manual Collection 6ES7998-8XC01-8YE0
Task: Electronic manuals on DVD,
Engineering tool for configuring and multi-language:
programming fail-safe user LOGO!, SIMADYN, SIMATIC bus
programs for components, SIMATIC C7,
SIMATIC S7-1200 FC, S7-1500F, SIMATIC Distributed I/O,
S7-1500F Software Controller, SIMATIC HMI, SIMATIC sensors,
S7-300F, S7-400F, WinAC RTX F, SIMATIC NET, SIMATIC PC-based
ET 200SP F Controller Automation, SIMATIC PCS 7,
and the fail-safe I/O SIMATIC PG/PC, SIMATIC S7,
ET 200SP, ET 200MP, ET 200S, SIMATIC software, SIMATIC TDC
ET 200M, ET 200iSP, ET 200pro and
ET 200eco SIMATIC Manual Collection 6ES7998-8XC01-8YE2
Requirement: update service for 1 year
STEP 7 Professional V17
Current Manual Collection DVD and
Note: the three subsequent updates
As of TIA Portal V16,
the SIMATIC STEP 7 Safety software
is an integral component of the
SIMATIC STEP 7 product setup.
The functionality of SIMATIC STEP 7
Safety is activated by means of the
license key supplied in each case.
Floating license for 1 user; 6ES7833-1FA17-0YA5
license key on USB flash drive
Floating license for 1 user, 6ES7833-1FA17-0YH5
license key for download1);
email address required for delivery
1) For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7511-1FK02-0AB0 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0
CPU 1511F-1PN, CPU 1513F-1 PN, CPU 1515F-2 PN, CPU 1516F-3 PN/DP,
225KB prog, 1MB data 450KB Prog., 1,5MB data 750KB Prog.,3MB Data 1,5MB Prog, 5MB Data
General information
Product type designation CPU 1511F-1 PN CPU 1513F-1 PN CPU 1515F-2 PN CPU 1516F-3 PN/DP
Engineering with
• STEP 7 TIA Portal V17 (FW V2.9) / V15 V17 (FW V2.9) / V15 V17 (FW V2.9) / V16 V17 (FW V2.9) / V16
configurable/integrated from version (FW V2.5) or higher; (FW V2.5) or higher; (FW V2.8) or higher; (FW V2.8) or higher;
with older TIA Portal
versions configurable as
with older TIA Portal
versions configurable as
with older TIA Portal
versions configurable as
with older TIA Portal
versions configurable as 4
6ES7511-1AK01-0AB0 6ES7513-1AL01-0AB0 6ES7515-2AM01-0AB0 6ES7516-3AN01-0AB0
Display
Screen diagonal [cm] 3.45 cm 3.45 cm 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 225 kbyte 450 kbyte 750 kbyte 1.5 Mbyte
• integrated (for data) 1 Mbyte 1.5 Mbyte 3 Mbyte 5 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), max. 32 Gbyte 32 Gbyte 32 Gbyte 32 Gbyte
CPU processing times
for bit operations, typ. 60 ns 40 ns 30 ns 10 ns
for word operations, typ. 72 ns 48 ns 36 ns 12 ns
for fixed point arithmetic, typ. 96 ns 64 ns 48 ns 16 ns
for floating point arithmetic, typ. 384 ns 256 ns 192 ns 64 ns
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048
IEC counter
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
S7 times
• Number 2 048 2 048 2 048 2 048
IEC timer
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the
process image process image process image process image
• Outputs 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in
the process image the process image the process image the process image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock Hardware clock
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2 2
• integrated switch Yes Yes Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes
• Media redundancy Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager
according to according to according to according to
IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0
■ Technical specifications
Article number 6ES7511-1FK02-0AB0 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0
CPU 1511F-1PN, CPU 1513F-1 PN, CPU 1515F-2 PN, CPU 1516F-3 PN/DP,
225KB prog, 1MB data 450KB Prog., 1,5MB data 750KB Prog.,3MB Data 1,5MB Prog, 5MB Data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1FK02-0AB0 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0
CPU 1511F-1PN, CPU 1513F-1 PN, CPU 1515F-2 PN, CPU 1516F-3 PN/DP,
225KB prog, 1MB data 450KB Prog., 1,5MB data 750KB Prog.,3MB Data 1,5MB Prog, 5MB Data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes
- Isochronous mode No No
- Direct data exchange
- IRT
No
No
No
No 4
- PROFIenergy Yes; per user program Yes; per user program
- Prioritized startup No No
- Number of connectable 32; In total, up to 32; In total, up to
IO Devices, max. 1 000 distributed I/O devices 1 000 distributed I/O devices
can be connected via AS-i, can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET
- Number of connectable 32 32
IO Devices for RT, max.
- of which in line, max. 32 32
- Number of IO Devices that 8; in total across all 8; in total across all
can be simultaneously interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8
max.
- Updating times The minimum value of the The minimum value of the
update time also depends update time also depends
on communication share set on communication share set
for PROFINET IO, on the for PROFINET IO, on the
number of IO devices, and number of IO devices, and
on the quantity of configured on the quantity of configured
user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes
- Isochronous mode No No
- IRT No No
- PROFIenergy Yes; per user program Yes; per user program
- Prioritized startup No No
- Shared device Yes Yes
- Number of IO Controllers with 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program
3. Interface
Interface types
• RS 485 Yes; X3
• Number of ports 1
Protocols
• PROFIBUS DP master Yes
• PROFIBUS DP slave No
• SIMATIC communication Yes
■ Technical specifications
Article number 6ES7511-1FK02-0AB0 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0
CPU 1511F-1PN, CPU 1513F-1 PN, CPU 1515F-2 PN, CPU 1516F-3 PN/DP,
225KB prog, 1MB data 450KB Prog., 1,5MB data 750KB Prog.,3MB Data 1,5MB Prog, 5MB Data
Protocols
Number of connections
• Number of connections, max. 96; via integrated interfaces 128; via integrated interfaces 192; via integrated interfaces 256; via integrated interfaces
of the CPU and of the CPU and of the CPU and of the CPU and
connected CPs / CMs connected CPs / CMs connected CPs / CMs connected CPs / CMs
4 Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) Yes; only via 1st interface (X1) only via 1st interface (X1) Yes; only via 1st interface (X1)
- MRP Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager
according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2
Edition 2.0, MRP Manager; Edition 2.0, MRP Manager; Edition 2.0, MRP Manager; Edition 2.0, MRP Manager;
MRP Client MRP Client MRP Client MRP Client
- MRP interconnection, supported Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node
according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2
Edition 3.0 Edition 3.0 Edition 3.0 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, bumpless 200 ms; For MRP, bumpless 200 ms; For MRP, bumpless 200 ms; For MRP, bumpless
for MRPD for MRPD for MRPD for MRPD
- Number of stations in the ring, 50 50 50 50
max.
SIMATIC communication
• S7 routing Yes Yes Yes Yes
OPC UA
• OPC UA Client Yes Yes Yes Yes
• OPC UA Server Yes; Data access (read, Yes; Data access (read, Yes; Data access (read, Yes; Data access (read,
write, subscribe), method write, subscribe), method write, subscribe), method write, subscribe), method
call, custom address space call, custom address space call, custom address space call, custom address space
• Alarms and Conditions Yes
Supported technology objects
Motion Control Yes; Note: The number of Yes; Note: The number of Yes; Note: The number of Yes; Note: The number of
technology objects affects technology objects affects technology objects affects technology objects affects
the cycle time of the PLC the cycle time of the PLC the cycle time of the PLC the cycle time of the PLC
program; selection guide via program; selection guide via program; selection guide via program; selection guide via
the TIA Selection Tool the TIA Selection Tool the TIA Selection Tool the TIA Selection Tool
• Number of available Motion Control 800 800 2 400 2 400
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40 40 40
- per positioning axis 80 80 80 80
- per synchronous axis 160 160 160 160
- per external encoder 80 80 80 80
- per output cam 20 20 20 20
- per cam track 160 160 160 160
- per probe 40 40 40 40
Controller
• PID_Compact Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller
with integrated optimization with integrated optimization with integrated optimization with integrated optimization
• PID_3Step Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization
for valves for valves for valves for valves
• PID-Temp Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization
for temperature for temperature for temperature for temperature
Counting and measuring
• High-speed counter Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1FK02-0AB0 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0
CPU 1511F-1PN, CPU 1513F-1 PN, CPU 1515F-2 PN, CPU 1516F-3 PN/DP,
225KB prog, 1MB data 450KB Prog., 1,5MB data 750KB Prog.,3MB Data 1,5MB Prog, 5MB Data
Standards, approvals, certificates
Highest safety class achievable
in safety mode
Probability of failure (for service
life of 20 years and repair time of
100 hours)
- Low demand mode: PFDavg in < 2.00E-05 < 2.00E-05 < 2.00E-05 < 2.00E-05 4
accordance with SIL3
- High demand/continuous mode: < 1.00E-09 < 1.00E-09 < 1.00E-09 < 1.00E-09
PFH in accordance with SIL3
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation
• horizontal installation, max. 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an 60 °C; Display: 50 °C, at an
operating temperature of operating temperature of operating temperature of operating temperature of
typically 50 °C, the display is typically 50 °C, the display is typically 50 °C, the display is typically 50 °C, the display is
switched off switched off switched off switched off
• vertical installation, min. -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation -25 °C; No condensation
• vertical installation, max. 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an 40 °C; Display: 40 °C, at an
operating temperature of operating temperature of operating temperature of operating temperature of
typically 40 °C, the display is typically 40 °C, the display is typically 40 °C, the display is typically 40 °C, the display is
switched off switched off switched off switched off
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for
max. installation altitudes installation altitudes installation altitudes installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Configuration
Programming
Programming language
- LAD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- FBD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- STL Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes Yes
protection
• Copy protection Yes Yes Yes Yes
• Block protection Yes Yes Yes Yes
Access protection
• Password for display Yes Yes Yes Yes
• Protection level: Write protection Yes; Specific write protection Yes; Specific write protection Yes; Specific write protection Yes; Specific write protection
both for Standard and for both for Standard and for both for Standard and for both for Standard and for
Failsafe Failsafe Failsafe Failsafe
• Protection level: Read/write Yes Yes Yes Yes
protection
• Protection level: Write protection for Yes Yes Yes Yes
Failsafe
• Protection level: Complete Yes Yes Yes Yes
protection
Dimensions
Width 35 mm 35 mm 70 mm 70 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 405 g 405 g 830 g 845 g
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
General information
Product type designation CPU 1517F-3PN/DP CPU 1518F-4PN/DP CPU 1518F-4 PN/DP MFP
Engineering with
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V13 Update 3 V17 (FW V2.9) / V13 (FW V1.5) or V17 (FW V2.9) / V15 (FW V2.5) or
integrated from version (FW V1.6) or higher higher higher
4 Display
Screen diagonal [cm] 6.1 cm 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 3 Mbyte 9 Mbyte 9 Mbyte
• integrated (for data) 8 Mbyte 60 Mbyte 60 Mbyte
• integrated (for CPU function library 50 Mbyte;
of CPU Runtime) Note: The "CPU function library of the
CPU" are C/C++ blocks for the user
program that were created using the
SIMATIC ODK 1500S or Target 1500S.
Working memory for additional
functions
• Integrated 512 Mbyte
(for C/C++ Runtime application)
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte 32 Gbyte; The memory card must have
max. at least 2 GB of space on it
CPU processing times
for bit operations, typ. 2 ns 1 ns 1 ns
for word operations, typ. 3 ns 2 ns 2 ns
for fixed point arithmetic, typ. 3 ns 2 ns 2 ns
for floating point arithmetic, typ. 12 ns 6 ns 6 ns
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048
IEC counter
• Number Any (only limited by the main memory) Any (only limited by the main memory) Any (only limited by the main memory)
S7 times
• Number 2 048 2 048 2 048
IEC timer
• Number Any (only limited by the main memory) Any (only limited by the main memory) Any (only limited by the main memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the process 32 kbyte; All inputs are in the process 32 kbyte; All inputs are in the process
image image image
• Outputs 32 kbyte; All outputs are in the process 32 kbyte; All outputs are in the process 32 kbyte; All outputs are in the process
image image image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2
• integrated switch
Protocols
Yes Yes Yes
4
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes
• PROFINET IO Device Yes Yes Yes
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes; Optionally also encrypted Yes; Optionally also encrypted Yes; Optionally also encrypted
• Web server Yes Yes Yes
• Media redundancy Yes; MRP Automanager according to Yes; MRP Automanager according to Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes
- Isochronous mode Yes Yes Yes
- Direct data exchange Yes; Requirement: IRT and Yes; Requirement: IRT and Yes; Requirement: IRT and
isochronous mode (MRPD optional) isochronous mode (MRPD optional) isochronous mode (MRPD optional)
- IRT Yes Yes Yes
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup Yes; Max. 32 PROFINET devices Yes; Max. 32 PROFINET devices Yes; Max. 32 PROFINET devices
- Number of connectable IO 512; In total, up to 1 000 distributed I/O 512; In total, up to 1 000 distributed I/O 512; In total, up to 1 000 distributed I/O
Devices, max. devices can be connected via AS-i, devices can be connected via AS-i, devices can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET PROFIBUS or PROFINET
- Of which IO devices with IRT, max. 64 64 64
- Number of connectable IO 512 512 512
Devices for RT, max.
- of which in line, max. 512 512 512
- Number of IO Devices that 8; in total across all interfaces 8; in total across all interfaces 8; in total across all interfaces
can be simultaneously
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8
max.
- Updating times The minimum value of the update time The minimum value of the update time The minimum value of the update time
also depends on communication share also depends on communication share also depends on communication share
set for PROFINET IO, on the number of set for PROFINET IO, on the number of set for PROFINET IO, on the number of
IO devices, and on the quantity of IO devices, and on the quantity of IO devices, and on the quantity of
configured user data configured user data configured user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes
- Isochronous mode No No No
- IRT Yes Yes; Minimum send cycle of 250 µs Yes; Minimum send cycle of 250 µs
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program
- Shared device Yes Yes Yes
- Number of IO Controllers with 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
2. Interface
Interface types
• RJ 45 (Ethernet) Yes; X2 Yes; X2 Yes; X2
• Number of ports 1 1 1
4 • integrated switch
Protocols
No No No
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
3. Interface
Interface types
• RJ 45 (Ethernet) Yes; X3 Yes; X3
• RS 485 Yes; X3
• Number of ports 1 1 1; C/C++ Runtime can also be
reached via this port 4
• integrated switch No No
Protocols
• IP protocol Yes; IPv4 Yes; IPv4
• PROFINET IO Controller No No
• PROFINET IO Device No No
• PROFIBUS DP master Yes
• PROFIBUS DP slave No
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes Yes
• Web server Yes Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to 1 000 distributed I/O 125; In total, up to 1 000 distributed I/O
devices can be connected via devices can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET
4. Interface
Interface types
• RS 485 Yes; X4 Yes; X4
• Number of ports 1 1
Protocols
• PROFIBUS DP master Yes Yes
• PROFIBUS DP slave No No
• SIMATIC communication Yes Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to 1 000 distributed I/O 125; In total, up to 1 000 distributed I/O
devices can be connected via AS-i, devices can be connected via AS-i,
PROFIBUS or PROFINET PROFIBUS or PROFINET
Protocols
Number of connections
• Number of connections, max. 320; via integrated interfaces of the 384; via integrated interfaces of the 384; via integrated interfaces of the
CPU and connected CPs / CMs CPU and connected CPs / CMs CPU and connected CPs / CMs
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) only via 1st interface (X1) only via 1st interface (X1)
- MRP Yes; as MRP redundancy manager Yes; as MRP redundancy manager Yes; as MRP redundancy manager
and/or MRP client and/or MRP client and/or MRP client
- MRP interconnection, supported Yes; as ring node according to Yes; as ring node according to Yes; as ring node according to
IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0 IEC 62439-2 Edition 2.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD 200 ms; For MRP, bumpless for MRPD 200 ms; For MRP, bumpless for MRPD
- Number of stations in the ring, 50 50 50
max.
SIMATIC communication
• S7 routing Yes Yes Yes
OPC UA
• OPC UA Client Yes Yes Yes
• OPC UA Server Yes; Data access (read, write, Yes; Data access (read, write, Yes; Data access (read, write,
subscribe), method call, custom subscribe), method call, custom subscribe), method call, custom
address space address space address space
• Alarms and Conditions Yes
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
Supported technology objects
Motion Control Yes; Note: The number of technology Yes; Note: The number of technology Yes; Note: The number of technology
objects affects the cycle time of the objects affects the cycle time of the objects affects the cycle time of the
PLC program; selection guide via the PLC program; selection guide via the PLC program; selection guide via the
TIA Selection Tool TIA Selection Tool TIA Selection Tool
■ Technical specifications
Article number 6ES7517-3FP00-0AB0 6ES7518-4FP00-0AB0 6ES7518-4FX00-1AC0
CPU 1517F-3 PN/DP, 3MB Prog., CPU 1518F-4 PN/DP, 6 MB Prog, CPU 1518F-4 PN/DP MFP +
8MB Data 20MB Data C/C++ RT +OPC UA
Configuration
Programming
Programming language
- LAD Yes; incl. failsafe Yes; incl. failsafe Yes
- FBD
- STL
Yes; incl. failsafe
Yes
Yes; incl. failsafe
Yes
Yes
Yes 4
- SCL Yes Yes Yes
- GRAPH Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes
protection
• Copy protection Yes Yes Yes
• Block protection Yes Yes Yes
Access protection
• Password for display Yes Yes Yes
• Protection level: Write protection Yes; Specific write protection both for Yes; Specific write protection both for Yes
Standard and for Failsafe Standard and for Failsafe
• Protection level: Read/write Yes Yes Yes
protection
• Protection level: Write protection Yes
for Failsafe
• Protection level: Complete Yes Yes Yes
protection
Open Development interfaces
• Size of ODK SO file, max. 9.8 Mbyte
Dimensions
Width 175 mm 175 mm 175 mm
Height 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm
Weights
Weight, approx. 1 978 g 1 988 g 2 117 g
• The CPU for standard and fail-safe applications with • The CPU for applications with medium to high requirements
medium/high requirements for program/data storage in the for program/data storage in the S7-1500 Controller product
SIPLUS S7-1500 Controller product range range
• High processing speed for binary and floating-point arithmetic • Can be used for failsafe functions up to SIL 3 according to
• Used as central PLC in production lines with central and IEC 61508 and up to PLe according to ISO 13849.
distributed I/O • Medium to high processing speed for binary and
• Supports PROFIsafe in centralized and distributed floating-point arithmetic
configuration • Used as central PLC in production lines with central and
• PROFINET IO IRT interface with 2-port switch distributed I/O
• PROFINET IO controller for operating distributed I/O on • Supports PROFIsafe in centralized and distributed
PROFINET configurations
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO IRT interface with 2-port switch
PROFINET device under a SIMATIC or non-Siemens • Additional PROFINET interface with separate IP address
PROFINET IO controller • PROFINET IO controller for operating distributed I/O on
• Isochronous mode PROFINET
Note: • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
SIMATIC Memory Card required for operation of the CPU. PROFINET IO controller
SIPLUS extreme products are based on SIMATIC standard • Isochronous mode
products. The contents listed here were taken from the • Integrated Motion Control functionalities for controlling
corresponding standard products. SIPLUS extreme-specific speed-controlled and positioning axes, support for external
information was added. encoders
• Integrated web server with the option of creating user-defined
web pages
Note:
SIMATIC Memory Card required for operation of the CPU.
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Overview SIPLUS CPU 1516F-3 PN/DP ■ Overview SIPLUS CPU 1518F-4 PN/DP
• The CPU with a large program and data memory in the • The CPU with a very large program and data memory in the
SIPLUS S7-1500 Controller product range for fail-safe SIPLUS S7-1500 Controller product range for fail-safe
applications with high requirements regarding program scope applications with highest requirements regarding program
and networking. scope, performance and networking.
• Can be used for failsafe functions up to SIL 3 according to • Can be used for failsafe functions up to SIL 3 according to
IEC 61508 and up to PLe according to ISO 13849. IEC 61508 and up to PLe according to ISO 13849.
• High processing speed for binary and floating-point arithmetic • Extremely high processing speed for binary and floating-point
• Used as central PLC in production lines with central and arithmetic.
distributed I/O. • For cross-industry automation tasks in series machine, special
• Supports PROFIsafe in centralized and distributed machine and plant construction
configuration. • Used as central PLC in production lines with central and
• PROFINET IO IRT interface with 2-port switch. distributed I/O.
• Additional PROFINET interface with separate IP address. • Supports PROFIsafe in centralized and distributed
configuration.
• PROFINET IO controller for operating distributed I/O on
PROFINET. • PROFINET IO IRT interface with 2-port switch.
• PROFINET I-Device for connecting the CPU as an intelligent • Two additional PROFINET interfaces with separate IP
PROFINET device under a SIMATIC or non-Siemens addresses.
PROFINET IO controller. • PROFINET IO controller for operating distributed I/O on
• PROFIBUS DP master interface. PROFINET.
• Isochronous mode on PROFIBUS and PROFINET. • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
• Integrated Motion Control functionalities for controlling speed- PROFINET IO controller.
controlled and positioning axes, support for external
encoders. • PROFIBUS DP master interface.
• Integrated web server with the option of creating user-defined • Isochronous mode on PROFIBUS and PROFINET.
Web pages. • Integrated Motion Control functionalities for controlling speed-
controlled and positioning axes, support for external encoders
Note:
• Integrated web server with the option of creating user-defined
SIMATIC Memory Card required for operation of the CPU Web pages.
SIPLUS extreme products are based on SIMATIC standard Note:
products. The contents listed here were taken from the
corresponding standard products. SIPLUS extreme-specific SIMATIC Memory Card required for operation of the CPU.
information was added. SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
corresponding standard products. SIPLUS extreme-specific
information was added.
Fail-safe CPU,
6 MB work memory for program,
20 MB for data,
PROFINET IRT interface
with 2-port switch,
PROFINET RT interface,
Ethernet interface,
PROFIBUS interface;
SIMATIC Memory Card required
■ Technical specifications
Article number 6AG1513-1FL02-2AB0 6AG1515-2FM02-2AB0 6AG1516-3FN02-2AB0 6AG1518-4FP00-4AB0
Based on 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0 6ES7518-4FP00-0AB0
SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU
1513F-1 PN 1515F-2 PN 1516F-3 PN/DP 1518F-4 PN/DP
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -25 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin 0 °C
(incl. condensation/frost) (incl. condensation/frost) (incl. condensation/frost)
• horizontal installation, max. 60 °C; = Tmax; display: 60 °C; = Tmax; display: 60 °C; = Tmax; display: 60 °C; Display: 50 °C, at an
50 °C, the display is switched 50 °C, the display is switched 50 °C, the display is switched operating temperature of
off at an operating off at an operating off at an operating typically 50 °C, the display is
temperature of typically 50 °C temperature of typically 50 °C temperature of typically 50 °C switched off
• vertical installation, min. -25 °C; = Tmin (incl. -40 °C; = Tmin -40 °C; = Tmin 0 °C
condensation/frost)
• vertical installation, max. 40 °C; Display: 40 °C, 40 °C; = Tmax; display: 40 °C; = Tmax; display: 40 °C; Display: 40 °C,
at an operating temperature of 40 °C, at an operating 40 °C, at an operating at an operating temperature of
typically 40 °C, the display is temperature of typically 40 °C, temperature of typically 40 °C, typically 40 °C, the display is
switched off the display is switched off the display is switched off switched off
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for 3 000 m
max. installation altitudes installation altitudes installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
• Ambient air temperature-barometric Restrictions for installation Restrictions for installation Restrictions for installation Restrictions for installation
pressure-altitude altitudes > 2 000 m, altitudes > 2 000 m, altitudes > 2 000 m, altitudes > 2 000 m,
see entry ID: 109763260 see entry ID: 109763260 see entry ID: 109763260 see entry ID: 109763260
■ Technical specifications
Article number 6AG1513-1FL02-2AB0 6AG1515-2FM02-2AB0 6AG1516-3FN02-2AB0 6AG1518-4FP00-4AB0
Based on 6ES7513-1FL02-0AB0 6ES7515-2FM02-0AB0 6ES7516-3FN02-0AB0 6ES7518-4FP00-0AB0
SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU SIPLUS S7-1500 CPU
1513F-1 PN 1515F-2 PN 1516F-3 PN/DP 1518F-4 PN/DP
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation / frost (no condensation / frost (no condensation / frost (no condensation/frost (no
max. commissioning in bedewed commissioning in bedewed commissioning in bedewed commissioning under
Resistance
state), horizontal installation state), horizontal installation state), horizontal installation condensation conditions)
4
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold, Yes; Class 6B2 mold, Yes; Class 6B2 mold, Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal and dry rot spores fungal and dry rot spores fungal and dry rot spores fungal spores (excluding
(excluding fauna) (excluding fauna) (excluding fauna) fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); permissible); permissible);
level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
• The CPU for applications with medium requirements for • The CPU for applications with high requirements for
program scope and processing speed, and increased availability, very high requirements for program scope and
requirements for availability. networking, and very high requirements for processing speed.
• High processing speed for binary and floating-point arithmetic • High processing speed for binary and floating-point arithmetic
• Used as the central controller in production lines with • Used as central controller with distributed I/O
distributed I/O • PROFINET IO RT interface with 2-port switch
• PROFINET IO RT interface with 2-port switch • Additional PROFINET interface with separate IP address
• PROFINET IO controller for operating distributed I/O on • PROFINET IO controller for operating distributed I/O on
PROFINET PROFINET
Note: Note:
SIMATIC Memory Card required for operation of the CPU SIMATIC Memory Card required for operation of the CPU
■ Technical specifications
Article number 6ES7513-1RL00-0AB0 6ES7515-2RM00-0AB0 6ES7517-3HP00-0AB0 6ES7518-4JP00-0AB0
CPU 1513R-1 PN, 300KB CPU 1515R-2 PN, 500KB CPU 1517H-3 PN, 2MB CPU 1518HF-4 PN, 9MB
program/1,5MB data program/ 3MB data program/8MB data program/60MB data
General information
Product type designation CPU 1513R-1 PN CPU 1515R-2 PN CPU 1517H-3 PN CPU 1518HF-4PN
Engineering with
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V16 V17 (FW V2.9) / V16 V17 (FW V2.9) / V16 V17
integrated from version (FW V2.8) / V15.1 (FW V2.6) (FW V2.8) / V15.1 (FW V2.6) (FW V2.8) / V15.1 (FW V2.6)
Display 4
Screen diagonal [cm] 3.45 cm 6.1 cm 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 300 kbyte 500 kbyte 2 Mbyte 9 Mbyte
• integrated (for data) 1.5 Mbyte 3 Mbyte 8 Mbyte 60 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte 32 Gbyte 32 Gbyte
max.
CPU processing times
for bit operations, typ. 80 ns 60 ns 4 ns 4 ns
for word operations, typ. 96 ns 72 ns 6 ns 6 ns
for fixed point arithmetic, typ. 128 ns 96 ns 6 ns 6 ns
for floating point arithmetic, typ. 512 ns 384 ns 24 ns 24 ns
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048
IEC counter
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
S7 times
• Number 2 048 2 048 2 048 2 048
IEC timer
• Number Any (only limited by the main Any (only limited by the main Any (only limited by the main Any (only limited by the main
memory) memory) memory) memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the 32 kbyte; All inputs are in the
process image process image process image process image
• Outputs 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in 32 kbyte; All outputs are in
the process image the process image the process image the process image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock Hardware clock
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2 2
• integrated switch Yes Yes Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device No No No No
• SIMATIC communication Yes; Only Server Yes; Only Server Yes; Only Server Yes; Only Server
• Open IE communication Yes Yes Yes Yes; Optionally also
encrypted
• Web server No No No No
• Media redundancy Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7513-1RL00-0AB0 6ES7515-2RM00-0AB0 6ES7517-3HP00-0AB0 6ES7518-4JP00-0AB0
CPU 1513R-1 PN, 300KB CPU 1515R-2 PN, 500KB CPU 1517H-3 PN, 2MB CPU 1518HF-4 PN, 9MB
program/1,5MB data program/ 3MB data program/8MB data program/60MB data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode No No No No
4 - IRT
- PROFIenergy
No
Yes
No
Yes
No
Yes
No
Yes; per user program
- Number of connectable 64 64 256 256
IO Devices, max.
- Updating times The minimum value of the
update time also depends
on communication share set
for PROFINET IO, on the
number of IO devices, and
on the quantity of configured
user data
2. Interface
Interface types
• RJ 45 (Ethernet) Yes; X2 Yes; X2 Yes; X2
• Number of ports 1 1 1
• integrated switch No No No
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller No No No
• PROFINET IO Device No No No
• SIMATIC communication Yes; Only Server Yes; Only Server Yes; Only Server
• Open IE communication Yes Yes Yes; Optionally also
encrypted
• Web server No No No
• Media redundancy No No No
3. Interface
Interface type Pluggable synchronization
submodule (FO)
Plug-in interface modules Synchronization module
6ES7960-1CB00-0AA5 or
6ES7960-1FB00-0AA5
Interface types
• RJ 45 (Ethernet) Yes; X3
• Number of ports 1
• integrated switch No
Protocols
• IP protocol Yes; IPv4
• SIMATIC communication Yes; Only Server
• Open IE communication Yes
4. Interface
Interface type Pluggable synchronization Pluggable synchronization
submodule (FO) submodule (FO)
Plug-in interface modules Synchronization module Synchronization module
6ES7960-1CB00-0AA5 or 6ES7960-1CB00-0AA5 or
6ES7960-1FB00-0AA5 6ES7960-1FB00-0AA5
■ Technical specifications
Article number 6ES7513-1RL00-0AB0 6ES7515-2RM00-0AB0 6ES7517-3HP00-0AB0 6ES7518-4JP00-0AB0
CPU 1513R-1 PN, 300KB CPU 1515R-2 PN, 500KB CPU 1517H-3 PN, 2MB CPU 1518HF-4 PN, 9MB
program/1,5MB data program/ 3MB data program/8MB data program/60MB data
Protocols
Number of connections
• Number of connections, max. 88 108 288 320
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface (X1) 4
- MRP Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager Yes; MRP Automanager
according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2
Edition 2.0 Edition 2.0 Edition 2.0 Edition 2.0
- MRP interconnection, supported Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node Yes; as MRP ring node
according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2 according to IEC 62439-2
Edition 3.0 Edition 3.0 Edition 3.0 Edition 3.0
- MRPD No No No No
- Switchover time on line break, typ. 200 ms; PROFINET MRP 200 ms; PROFINET MRP 200 ms; PROFINET MRP 200 ms; PROFINET MRP
- Number of stations in the ring, 50; Only 16 are 50; Only 16 are 50 50
max. recommended, however recommended, however
SIMATIC communication
• S7 routing No Yes Yes Yes
OPC UA
• OPC UA Client No No No No
• OPC UA Server No No No No
Supported technology objects
Motion Control No No No No
Controller
• PID_Compact Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller Yes; Universal PID controller
with integrated optimization with integrated optimization with integrated optimization with integrated optimization
• PID_3Step Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization for integrated optimization for integrated optimization for integrated optimization for
valves valves valves valves
• PID-Temp Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization for integrated optimization for integrated optimization for integrated optimization for
temperature temperature temperature temperature
Counting and measuring Yes Yes Yes Yes
• High-speed counter No No No No
Standards, approvals, certificates
Highest safety class achievable in
safety mode
Probability of failure (for service
life of 20 years and repair time of
100 hours)
- Low demand mode: PFDavg < 2.00E-05
in accordance with SIL3
- High demand/continuous mode: < 1.00E-09
PFH in accordance with SIL3
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. 0 °C 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C,
at an operating temperature at an operating temperature at an operating temperature at an operating temperature
of typically 50 °C, the display of typically 50 °C, the display of typically 50 °C, the display of typically 50 °C, the display
is switched off is switched off is switched off is switched off
• vertical installation, min. 0 °C 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C,
at an operating temperature at an operating temperature at an operating temperature at an operating temperature
of typically 40 °C, the display of typically 40 °C, the display of typically 40 °C, the display of typically 40 °C, the display
is switched off is switched off is switched off is switched off
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for 5 000 m; Restrictions for 5 000 m; Restrictions for 3 000 m; Restrictions for
max. installation altitudes installation altitudes installation altitudes installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
■ Technical specifications
Article number 6ES7513-1RL00-0AB0 6ES7515-2RM00-0AB0 6ES7517-3HP00-0AB0 6ES7518-4JP00-0AB0
CPU 1513R-1 PN, 300KB CPU 1515R-2 PN, 500KB CPU 1517H-3 PN, 2MB CPU 1518HF-4 PN, 9MB
program/1,5MB data program/ 3MB data program/8MB data program/60MB data
Configuration
Programming
Programming language
- LAD Yes Yes Yes Yes; incl. failsafe
4 - FBD
- STL
Yes
Yes
Yes
Yes
Yes
Yes
Yes; incl. failsafe
Yes
- SCL Yes Yes Yes Yes
- CFC No No No
- GRAPH Yes Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes Yes
password protection
• Copy protection No No No Yes
• Block protection Yes Yes Yes Yes
Access protection
• protection of confidential Yes Yes Yes Yes
configuration data
• Password for display Yes Yes Yes Yes
• Protection level: Write protection Yes Yes Yes Yes
• Protection level: Read/write Yes Yes Yes Yes
protection
• Protection level: Write protection Yes
for Failsafe
• Protection level: Complete Yes Yes Yes Yes
protection
Dimensions
Width 35 mm 70 mm 210 mm 210 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 430 g 830 g 2 119 g;
Interface modules: 2x 18 g
■ Technical specifications
Article number 6AG1515-2RM00-7AB0 6AG1517-3HP00-4AB0
Based on 6ES7515-2RM00-0AB0 6ES7517-3HP00-0AB0
SIPLUS S7-1500 CPU 1515R-2 PN SIPLUS S7-1500 CPU 1517H-3 PN
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -20 °C 0 °C; = Tmin
• Entry-level CPU in the S7-1500T Controller product range • Entry-level CPU in the S7-1500T Controller product range
• Suitable for applications with medium requirements for • Suitable for standard and fail-safe applications with medium
program scope and processing speed requirements for program scope and processing speed
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O
• PROFINET IO IRT interface with 2-port switch • Can be used for safety functions up to SIL 3 according to
• PROFINET IO controller for operating distributed I/O on IEC 61508 and up to PLe according to ISO 13849
PROFINET • PROFINET IO IRT interface with 2-port switch
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO controller for operating distributed I/O on
PROFINET device under a SIMATIC or non-Siemens PROFINET
PROFINET IO controller • PROFINET I-Device for connecting the CPU as an intelligent
• OPC UA Server and Client as runtime option for the easy PROFINET device under a SIMATIC or non-Siemens
connection of SIMATIC S7-1500 to non-Siemens PROFINET IO controller
devices/systems with the functions: • OPC UA Server and Client as runtime option for the easy
- OPC UA Data Access connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Security devices/systems with the functions:
- OPC UA Methods Call
- Support of OPC UA Companion specifications. • OPC UA Data Access
• Central and distributed isochronous mode • OPC UA Security
• Integrated Motion Control functionalities for controlling • OPC UA Methods Call
speed-controlled, positioning and synchronized axes • Support of OPC UA Companion specifications.
(gearing and camming), support for external encoders, • Central and distributed isochronous mode
output cams/cam tracks and probes.
Technology object for controlling kinematics with up to • Integrated Motion Control functionalities for controlling
4 interpolating axes, e.g. Cartesian portal, delta picker, speed-controlled, positioning and synchronized axes
roller picker, articulated arm, cylindrical robot, tripod picker (gearing and camming), support for external encoders,
and SCARA. output cams/cam tracks and probes.
User-defined kinematics are also supported. Technology object for controlling kinematics with up to
4 interpolating axes, e.g. Cartesian portal, delta picker,
• Cross-PLC synchronous operation for synchronization roller picker, articulated arm, cylindrical robot, tripod picker
of multiple SIMATIC S7-1500T Controllers and SCARA.
• Integrated web server for diagnostics with the option User-defined kinematics are also supported.
of creating user-defined web pages • Cross-PLC synchronous operation for synchronization
Note: of multiple SIMATIC S7-1500T Controllers
SIMATIC Memory Card required for operation of the CPU • Integrated web server for diagnostics with the option
of creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU.
• The CPU for applications with medium to high requirements • The CPU for standard and fail-safe applications with medium
regarding program/data storage in the S7-1500T Controller to high requirements regarding program/data storage in the
product range S7-1500T Controller product range
• Medium to high processing speed for binary and • Medium to high processing speed for binary and
floating-point arithmetic floating-point arithmetic
• Used as central PLC in production lines with central and • Used as central PLC in production lines with central and
distributed I/O distributed I/O
• PROFINET IO IRT interface with 2-port switch • Can be used for safety functions up to SIL 3 according to
• PROFINET IO controller for operating distributed I/O on IEC 61508 and up to PLe according to ISO 13849
PROFINET • PROFINET IO IRT interface with 2-port switch
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO controller for operating distributed I/O on
PROFINET device under a SIMATIC or non-Siemens PROFINET
PROFINET IO controller • PROFINET I-Device for connecting the CPU as an intelligent
• Additional PROFINET interface with separate IP address for PROFINET device under a SIMATIC or non-Siemens
network separation, for connecting further PROFINET IO RT PROFINET IO controller
devices, or for high-speed communication as an I-Device • Additional PROFINET interface with separate IP address for
• OPC UA Server and Client as runtime option for the easy network separation, for connecting further PROFINET IO RT
connection of SIMATIC S7-1500 to non-Siemens devices, or for high-speed communication as an I-Device
devices/systems with the functions: • OPC UA Server and Client as runtime option for the easy
- OPC UA Data Access connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Security devices/systems with the functions:
- OPC UA Methods Call - OPC UA Data Access
- Support of OPC UA Companion specifications. - OPC UA Security
• Central and distributed isochronous mode - OPC UA Methods Call
• Integrated Motion Control functionalities for controlling - Support of OPC UA Companion specifications.
speed-controlled, positioning and synchronized axes • Isochronous mode centrally and distributed
(gearing and camming), support for external encoders, • Integrated Motion Control functionalities for controlling
output cams/cam tracks and probes. speed-controlled, positioning and synchronized axes
Technology object for controlling kinematics with up to (gearing and camming), support for external encoders,
4 interpolating axes, e.g. Cartesian portal, delta picker, output cams/cam tracks and probes.
roller picker, articulated arm, cylindrical robot, tripod picker Technology object for controlling kinematics with up to
and SCARA. 4 interpolating axes, e.g. Cartesian portal, delta picker,
User-defined kinematics are also supported. roller picker, articulated arm, cylindrical robot, tripod picker
• Cross-PLC synchronous operation for synchronization and SCARA.
of multiple SIMATIC S7-1500T Controllers User-defined kinematics are also supported.
• Integrated web server for diagnostics with the option • Cross-PLC synchronous operation for synchronization
of creating user-defined web pages of multiple SIMATIC S7-1500T Controllers
Note: • Integrated web server for diagnostics with the option
of creating user-defined web pages
SIMATIC Memory Card required for operation of the CPU.
Note:
SIMATIC Memory Card required for operation of the CPU.
• The CPU with a large program and data memory in the • The CPU with a large program and data memory in the
S7-1500 Controller product range for applications with high S7-1500 Controller product range for standard and fail-safe
requirements regarding program scope and networking. applications with high requirements regarding program scope
• High processing speed for binary and floating-point arithmetic and networking.
• For cross-industry automation tasks in series machine, • Can be used for safety functions up to SIL 3 according to
special machine and plant construction IEC 61508 and up to PLe according to ISO 13849
• Used as central PLC in production lines with central and • High processing speed for binary and floating-point arithmetic
distributed I/O • For cross-industry automation tasks in series machine, special
• PROFINET IO IRT interface with 2-port switch machine and plant construction
• PROFINET IO controller for operating distributed I/O on • Used as central PLC in production lines with central and
PROFINET. distributed I/O
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO IRT interface with 2-port switch
PROFINET device under a SIMATIC or non-Siemens • PROFINET IO controller for operating distributed I/O on
PROFINET IO controller PROFINET
• Additional PROFINET interface with separate IP address for • PROFINET I-Device for connecting the CPU as an intelligent
network separation, for connecting further PROFINET IO RT PROFINET device under a SIMATIC or non-Siemens
devices, or for high-speed communication as an I-Device PROFINET IO controller
• PROFIBUS DP master interface • Additional PROFINET interface with separate IP address for
• OPC UA Server and Client as runtime option for the easy network separation, for connecting further PROFINET IO RT
connection of SIMATIC S7-1500 to non-Siemens devices, or for high-speed communication as an I-Device
devices/systems with the functions: • PROFIBUS DP master interface
- OPC UA Data Access • OPC UA Server and Client as runtime option for the easy
- OPC UA Security connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Methods Call devices/systems with the functions:
- Support of OPC UA Companion specifications. - OPC UA Data Access
• Central and distributed isochronous mode on PROFIBUS and - OPC UA Security
PROFINET - OPC UA Methods Call
• Integrated Motion Control functionalities for controlling - Support of OPC UA Companion specifications.
speed-controlled, positioning and synchronized axes • Central and distributed isochronous mode on PROFIBUS and
(gearing and camming), support for external encoders, PROFINET
output cams/cam tracks and probes. • Integrated Motion Control functionalities for controlling
Technology object for controlling kinematics with up to speed-controlled, positioning and synchronized axes
4 interpolating axes, e.g. Cartesian portal, delta picker, (gearing and camming), support for external encoders,
roller picker, articulated arm, cylindrical robot, tripod picker output cams/cam tracks and probes.
and SCARA. Technology object for controlling kinematics with up to
User-defined kinematics are also supported. 4 interpolating axes, e.g. Cartesian portal, delta picker,
• Cross-PLC synchronous operation for synchronization roller picker, articulated arm, cylindrical robot, tripod picker
of multiple SIMATIC S7-1500T Controllers and SCARA.
• Integrated web server for diagnostics with the option User-defined kinematics are also supported.
of creating user-defined web pages • Cross-PLC synchronous operation for synchronization
of multiple SIMATIC S7-1500T Controllers
Note:
• Integrated web server for diagnostics with the option
SIMATIC Memory Card required for operation of the CPU. of creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU.
• The CPU with a very large program and data memory in the • The CPU with a very large program and data memory in the
S7-1500 Controller product range for applications with high S7-1500 Controller product range for fail-safe applications
requirements regarding program scope and networking. with high requirements regarding program scope and
• High processing speed for binary and floating-point arithmetic networking.
• For cross-industry automation tasks in series machine, special • Can be used for safety functions up to SIL 3 according to
machine and plant construction IEC 61508 and up to PLe according to ISO 13849
• Used as central PLC in production lines with central and • High processing speed for binary and floating-point arithmetic
distributed I/O • For cross-industry automation tasks in series machine, special
• PROFINET IO IRT interface with 2-port switch machine and plant construction
• PROFINET IO controller for operating distributed I/O on • Used as central PLC in production lines with central and
PROFINET. distributed I/O
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO IRT interface with 2-port switch
PROFINET device under a SIMATIC or non-Siemens • PROFINET IO controller for operating distributed I/O on
PROFINET IO controller PROFINET.
• Additional PROFINET interface with separate IP address for • PROFINET I-Device for connecting the CPU as an intelligent
network separation, for connecting further PROFINET IO RT PROFINET device under a SIMATIC or non-Siemens
devices, or for high-speed communication as an I-Device PROFINET IO controller
• PROFIBUS DP master interface • Additional PROFINET interface with separate IP address for
• OPC UA Server and Client as runtime option for the easy network separation, for connecting further PROFINET IO RT
connection of SIMATIC S7-1500 to non-Siemens devices, or for high-speed communication as an I-Device
devices/systems with the functions: • PROFIBUS DP master interface
- OPC UA Data Access • OPC UA Server and Client as runtime option for the easy
- OPC UA Security connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Methods Call devices/systems with the functions:
- Support of OPC UA Companion specifications. - OPC UA Data Access
• Central and distributed isochronous mode on PROFIBUS and - OPC UA Security
PROFINET - OPC UA Methods Call
• Integrated Motion Control functionalities for controlling - Support of OPC UA Companion specifications.
speed-controlled, positioning and synchronized axes • Central and distributed isochronous mode on PROFIBUS and
(gearing and camming), support for external encoders, PROFINET
output cams/cam tracks and probes. • Integrated Motion Control functionalities for controlling
Technology object for controlling kinematics with up to speed-controlled, positioning and synchronized axes
4 interpolating axes, e.g. Cartesian portal, delta picker, (gearing and camming), support for external encoders,
roller picker, articulated arm, cylindrical robot, tripod picker output cams/cam tracks and probes.
and SCARA. Technology object for controlling kinematics with up to
User-defined kinematics are also supported. 4 interpolating axes, e.g. Cartesian portal, delta picker,
• Cross-PLC synchronous operation for synchronization roller picker, articulated arm, cylindrical robot, tripod picker
of multiple SIMATIC S7-1500T Controllers and SCARA.
• Integrated web server for diagnostics with the option User-defined kinematics are also supported.
of creating user-defined web pages • Cross-PLC synchronous operation for synchronization
of multiple SIMATIC S7-1500T Controllers
Note:
• Integrated web server for diagnostics with the option
SIMATIC Memory Card required for operation of the CPU. of creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU.
• The CPU with a very large program and data memory in the • The CPU with a very large program and data memory in the
S7-1500 Controller product range for applications with high S7-1500 Controller product range for fail-safe applications
requirements regarding program scope and networking. with high requirements regarding program scope and
• High processing speed for binary and floating-point arithmetic networking.
• For cross-industry automation tasks in series machine, special • Can be used for safety functions up to SIL 3 according to
machine and plant construction IEC 61508 and up to PLe according to ISO 13849
• Used as central PLC in production lines with central and • High processing speed for binary and floating-point arithmetic
distributed I/O • For cross-industry automation tasks in series machine, special
• PROFINET IO IRT interface with 2-port switch machine and plant construction
• PROFINET IO controller for operating distributed I/O on • Used as central PLC in production lines with central and
PROFINET distributed I/O
• PROFINET I-Device for connecting the CPU as an intelligent • PROFINET IO IRT interface with 2-port switch
PROFINET device under a SIMATIC or non-Siemens • PROFINET IO controller for operating distributed I/O on
PROFINET IO controller PROFINET
• Additional PROFINET interface with separate IP address for • PROFINET I-Device for connecting the CPU as an intelligent
network separation, for connecting further PROFINET IO RT PROFINET device under a SIMATIC or non-Siemens
devices, or for high-speed communication as an I-Device PROFINET IO controller
• PROFIBUS DP master interface • Additional PROFINET interface with separate IP address for
• OPC UA Server and Client as runtime option for the easy network separation, for connecting further PROFINET IO RT
connection of SIMATIC S7-1500 to non-Siemens devices, or for high-speed communication as an I-Device
devices/systems with the functions: • PROFIBUS DP master interface
- OPC UA Data Access • OPC UA Server and Client as runtime option for the easy
- OPC UA Security connection of SIMATIC S7-1500 to non-Siemens
- OPC UA Methods Call devices/systems with the functions:
- Support of OPC UA Companion specifications. - OPC UA Data Access
• Central and distributed isochronous mode on PROFIBUS and - OPC UA Security
PROFINET - OPC UA Methods Call
• Integrated Motion Control functionalities for controlling - Support of OPC UA Companion specifications.
speed-controlled, positioning and synchronized axes • Central and distributed isochronous mode on PROFIBUS and
(gearing and camming), support for external encoders, PROFINET
output cams/cam tracks and probes. • Integrated Motion Control functionalities for controlling
Technology object for controlling kinematics with up to speed-controlled, positioning and synchronized axes
4 interpolating axes, e.g. Cartesian portal, delta picker, (gearing and camming), support for external encoders,
roller picker, articulated arm, cylindrical robot, tripod picker output cams/cam tracks and probes.
and SCARA. Technology object for controlling kinematics with up to
User-defined kinematics are also supported. 4 interpolating axes, e.g. Cartesian portal, delta picker,
• Cross-PLC synchronous operation for synchronization roller picker, articulated arm, cylindrical robot, tripod picker
of multiple SIMATIC S7-1500T Controllers and SCARA.
• Integrated web server for diagnostics with the option User-defined kinematics are also supported.
of creating user-defined web pages • Cross-PLC synchronous operation for synchronization
of multiple SIMATIC S7-1500T Controllers
Note:
• Integrated web server for diagnostics with the option
SIMATIC Memory Card required for operation of the CPU. of creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU.
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
General information
Product type designation CPU 1511T-1 PN CPU 1515T-2 PN CPU 1516T-3 PN/DP CPU 1517T-3 PN/DP CPU 1518T-4 PN/DP
Engineering with
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V14 V17 (FW V2.9) / V14 V17 (FW V2.9) / V15 V17 (FW V2.9) / V14 V17 (FW V2.9) / V17
integrated from version (FW V2.0) or higher (FW V2.0) or higher (FW V2.5) or higher (FW V2.0) or higher (FW V2.9) or higher
Display
Screen diagonal [cm] 3.45 cm 6.1 cm 6.1 cm 6.1 cm 6.1 cm
Supply voltage
Type of supply voltage 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Memory
Work memory
• integrated (for program) 225 kbyte 750 kbyte 1.5 Mbyte 3 Mbyte 9 Mbyte
• integrated (for data) 1 Mbyte 3 Mbyte 5 Mbyte 8 Mbyte 60 Mbyte
Load memory
• Plug-in (SIMATIC Memory Card), 32 Gbyte 32 Gbyte 32 Gbyte 32 Gbyte 32 Gbyte
max.
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
CPU processing times
for bit operations, typ. 60 ns 30 ns 10 ns 2 ns 1 ns
for word operations, typ. 72 ns 36 ns 12 ns 3 ns 2 ns
for fixed point arithmetic, typ.
for floating point arithmetic, typ.
96 ns
384 ns
48 ns
192 ns
16 ns
64 ns
3 ns
12 ns
2 ns
6 ns
4
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048 2 048
IEC counter
• Number Any (only limited by Any (only limited by Any (only limited by Any (only limited by Any (only limited by
the main memory) the main memory) the main memory) the main memory) the main memory)
S7 times
• Number 2 048 2 048 2 048 2 048 2 048
IEC timer
• Number Any (only limited by Any (only limited by Any (only limited by Any (only limited by Any (only limited by
the main memory) the main memory) the main memory) the main memory) the main memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are
in the process image in the process image in the process image in the process image in the process image
• Outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs
are in the process are in the process are in the process are in the process are in the process
image image image image image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock Hardware clock Hardware clock
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2 2 2
• integrated switch Yes Yes Yes Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes Yes
• Media redundancy Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes Yes
4 - Isochronous mode
- Direct data exchange
Yes Yes Yes Yes Yes
Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
and isochronous mode and isochronous mode and isochronous mode and isochronous mode and isochronous mode
(MRPD optional) (MRPD optional) (MRPD optional) (MRPD optional) (MRPD optional)
- IRT Yes Yes Yes Yes Yes
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup Yes; Max. 32 Yes; Max. 32 Yes; Max. 32 Yes; Max. 32 Yes; Max. 32
PROFINET devices PROFINET devices PROFINET devices PROFINET devices PROFINET devices
- Number of connectable IO 128; In total, up to 256; In total, up to 256; In total, up to 512; In total, up to 512; In total, up to
Devices, max. 256 distributed I/O 1 000 distributed I/O 1 000 distributed I/O 1 000 distributed I/O 1 000 distributed I/O
devices can be devices can be devices can be devices can be devices can be
connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or
PROFINET PROFINET PROFINET PROFINET PROFINET
- Of which IO devices with IRT, max. 64 64 64 64 64
- Number of connectable IO 128 256 256 512 512
Devices for RT, max.
- of which in line, max. 128 256 256 512 512
- Number of IO Devices that 8; in total across all 8; in total across all 8; in total across all 8; in total across all 8; in total across all
can be simultaneously interfaces interfaces interfaces interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8 8 8
max.
- Updating times The minimum value of The minimum value of The minimum value of The minimum value of The minimum value of
the update time also the update time also the update time also the update time also the update time also
depends on depends on depends on depends on depends on
communication share communication share communication share communication share communication share
set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO,
on the number of IO on the number of IO on the number of IO on the number of IO on the number of IO
devices, and on the devices, and on the devices, and on the devices, and on the devices, and on the
quantity of configured quantity of configured quantity of configured quantity of configured quantity of configured
user data user data user data user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes Yes Yes
- Isochronous mode No No No No No
- IRT Yes Yes Yes Yes Yes; Minimum send
cycle of 250 µs
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Shared device Yes Yes Yes Yes Yes
- Number of IO Controllers with 4 4 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
2. Interface
Interface types
• RJ 45 (Ethernet) Yes; X2 Yes; X2 Yes; X2 Yes; X2
• Number of ports 1 1 1 1
• integrated switch No No No No
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes
• Media redundancy No No No No
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode
- Direct data exchange
No
No
No
No
No
No
No
No
4
- IRT No No No No
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup No No No No
- Number of connectable IO 32; In total, up to 32; In total, up to 128; In total, up to 128; In total, up to
Devices, max. 1 000 distributed 1 000 distributed 1 000 distributed 1 000 distributed
I/O devices can be I/O devices can be I/O devices can be I/O devices can be
connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or
PROFINET PROFINET PROFINET PROFINET
- Number of connectable 32 32 128 128
IO Devices for RT, max.
- of which in line, max. 32 32 128 128
- Number of IO Devices that 8; in total across all 8; in total across all 8; in total across all 8; in total across all
can be simultaneously interfaces interfaces interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8 8
max.
- Updating times The minimum value of The minimum value of The minimum value of The minimum value of
the update time also the update time also the update time also the update time also
depends on depends on depends on depends on
communication share communication share communication share communication share
set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO,
on the number of on the number of on the number of on the number of
IO devices, and on the IO devices, and on the IO devices, and on the IO devices, and on the
quantity of configured quantity of configured quantity of configured quantity of configured
user data user data user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode No No No No
- IRT No No No No
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup No No No No
- Shared device Yes Yes Yes Yes
- Number of IO Controllers with 4 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program Yes; per user program
3. Interface
Interface types
• RJ 45 (Ethernet) Yes; X3
• RS 485 Yes; X3 Yes; X3
• Number of ports 1 1 1
• integrated switch No
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
Protocols
• IP protocol Yes; IPv4
• PROFINET IO Controller No
4 • PROFINET IO Device
• PROFIBUS DP master Yes Yes
No
• PROFIBUS DP slave No No
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes
• Web server Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to 125; In total, up to
1 000 distributed 1 000 distributed
I/O devices can be I/O devices can be
connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or
PROFINET PROFINET
4. Interface
Interface types
• RS 485 Yes; X4
• Number of ports 1
Protocols
• PROFIBUS DP master Yes
• PROFIBUS DP slave No
• SIMATIC communication Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to
1 000 distributed
I/O devices can be
connected via AS-i,
PROFIBUS or
PROFINET
Protocols
Number of connections
• Number of connections, max. 96; via integrated 192; via integrated 256; via integrated 320; via integrated 384; via integrated
interfaces of the CPU interfaces of the CPU interfaces of the CPU interfaces of the CPU interfaces of the CPU
and connected and connected and connected and connected and connected
CPs / CMs CPs / CMs CPs / CMs CPs / CMs CPs / CMs
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface only via 1st interface only via 1st interface only via 1st interface only via 1st interface
(X1) (X1) (X1) (X1) (X1)
- MRP Yes; MRP Yes; MRP Yes; MRP Yes; MRP Yes; MRP
Automanager Automanager Automanager Automanager Automanager
according to according to according to according to according to
IEC 62439-2 IEC 62439-2 IEC 62439-2 IEC 62439-2 IEC 62439-2
Edition 2.0, Edition 2.0, Edition 2.0, Edition 2.0, Edition 2.0,
MRP Manager; MRP Manager; MRP Manager; MRP Manager; MRP Manager;
MRP Client MRP Client MRP Client MRP Client MRP Client
- MRP interconnection, supported Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring
node according to node according to node according to node according to node according to
IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP,
bumpless for MRPD bumpless for MRPD bumpless for MRPD bumpless for MRPD bumpless for MRPD
- Number of stations in the ring, 50 50 50 50 50
max.
SIMATIC communication
• S7 routing Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
OPC UA
• OPC UA Client Yes Yes Yes Yes Yes
• OPC UA Server Yes; Data access Yes; Data access Yes; Data access Yes; Data access Yes; Data access
(read, write, subscribe),
method call, custom
address space
(read, write, subscribe),
method call, custom
address space
(read, write, subscribe),
method call, custom
address space
(read, write, subscribe),
method call, custom
address space
(read, write, subscribe),
method call, custom
address space
4
• Alarms and Conditions Yes Yes Yes Yes Yes
Supported technology objects
Motion Control Yes; Note: The number Yes; Note: The number Yes; Note: The number Yes; Note: The number Yes; Note: The number
of technology objects of technology objects of technology objects of technology objects of technology objects
affects the cycle time affects the cycle time affects the cycle time affects the cycle time affects the cycle time
of the PLC program; of the PLC program; of the PLC program; of the PLC program; of the PLC program;
selection guide via the selection guide via the selection guide via the selection guide via the selection guide via the
TIA Selection Tool TIA Selection Tool TIA Selection Tool TIA Selection Tool TIA Selection Tool
• Number of available Motion Control 800 2 400 6 400 10 240 15 360
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40 40 40 40
- per positioning axis 80 80 80 80 80
- per synchronous axis 160 160 160 160 160
- per external encoder 80 80 80 80 80
- per output cam 20 20 20 20 20
- per cam track 160 160 160 160 160
- per probe 40 40 40 40 40
• Number of available Extended 40 120 192 256 512
Motion Control resources for
technology objects
• Required Extended Motion Control
resources
- per cam (1 000 points and 50 2 2 2 2 2
segments)
- per cam (10 000 points and 50 20 20 20 20 20
segments)
- for each set of kinematics 30 30 30 30 30
- Per leading axis proxy 3 3 3 3 3
Controller
• PID_Compact Yes; Universal PID Yes; Universal PID Yes; Universal PID Yes; Universal PID Yes; Universal PID
controller with controller with controller with controller with controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
• PID_3Step Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
for valves for valves for valves for valves for valves
• PID-Temp Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
for temperature for temperature for temperature for temperature for temperature
Counting and measuring
• High-speed counter Yes Yes Yes Yes Yes
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. 0 °C 0 °C 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C,
at an operating at an operating at an operating at an operating at an operating
temperature of temperature of temperature of temperature of temperature of
typically 50 °C, the typically 50 °C, the typically 50 °C, the typically 50 °C, the typically 50 °C, the
display is switched off display is switched off display is switched off display is switched off display is switched off
• vertical installation, min. 0 °C 0 °C 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C,
at an operating at an operating at an operating at an operating at an operating
temperature of temperature of temperature of temperature of temperature of
typically 40 °C, the typically 40 °C, the typically 40 °C, the typically 40 °C, the typically 40 °C, the
display is switched off display is switched off display is switched off display is switched off display is switched off
■ Technical specifications
Article number 6ES7511-1TK01- 6ES7515-2TM01- 6ES7516-3TN00- 6ES7517-3TP00- 6ES7518-4TP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511T-1PN, CPU 1515T-2 PN, CPU 1516T-3 PN/DP, CPU 1517T-3 PN/DP, CPU 1518T-4 PN/DP,
225KB progr., 1MB 750KB progr, 3MB 1.5MB prog./5MB 3MB prog./8MB data 9MB Prog., 60MB
data data data data
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions
4
max. for installation altitudes for installation altitudes for installation altitudes for installation altitudes for installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Configuration
Programming
Programming language
- LAD Yes Yes Yes Yes Yes
- FBD Yes Yes Yes Yes Yes
- STL Yes Yes Yes Yes Yes
- SCL Yes Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes Yes Yes
protection
• Copy protection Yes Yes Yes Yes Yes
• Block protection Yes Yes Yes Yes Yes
Access protection
• protection of confidential Yes Yes Yes Yes Yes
configuration data
• Password for display Yes Yes Yes Yes Yes
• Protection level: Write protection Yes Yes Yes Yes Yes
• Protection level: Read/write Yes Yes Yes Yes Yes
protection
• Protection level: Complete Yes Yes Yes Yes Yes
protection
Dimensions
Width 35 mm 70 mm 175 mm 175 mm 175 mm
Height 147 mm 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 430 g 830 g 1 978 g 1 978 g 1 988 g
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
CPU processing times
for bit operations, typ. 60 ns 30 ns 10 ns 2 ns 1 ns
for word operations, typ. 72 ns 36 ns 12 ns 3 ns 2 ns
for fixed point arithmetic, typ. 96 ns 48 ns 16 ns 3 ns 2 ns
for floating point arithmetic, typ. 384 ns 192 ns 64 ns 12 ns 6 ns 4
Counters, timers and their
retentivity
S7 counter
• Number 2 048 2 048 2 048 2 048 2 048
IEC counter
• Number Any (only limited by Any (only limited by Any (only limited by Any (only limited by Any (only limited by
the main memory) the main memory) the main memory) the main memory) the main memory)
S7 times
• Number 2 048 2 048 2 048 2 048 2 048
IEC timer
• Number Any (only limited by Any (only limited by Any (only limited by Any (only limited by Any (only limited by
the main memory) the main memory) the main memory) the main memory) the main memory)
Data areas and their retentivity
Flag
• Size, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
Address area
I/O address area
• Inputs 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are 32 kbyte; All inputs are
in the process image in the process image in the process image in the process image in the process image
• Outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs 32 kbyte; All outputs
are in the process are in the process are in the process are in the process are in the process
image image image image image
Time of day
Clock
• Type Hardware clock Hardware clock Hardware clock Hardware clock Hardware clock
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 Yes; X1 Yes; X1 Yes; X1 Yes; X1
• Number of ports 2 2 2 2 2
• integrated switch Yes Yes Yes Yes Yes
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes Yes
• Media redundancy Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes Yes
- Isochronous mode Yes Yes Yes Yes Yes
4 - Direct data exchange Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
and isochronous mode and isochronous mode and isochronous mode and isochronous mode and isochronous mode
(MRPD optional) (MRPD optional) (MRPD optional) (MRPD optional) (MRPD optional)
- IRT Yes Yes Yes Yes Yes
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup Yes; Max. 32 PROFINET Yes; Max. 32 PROFINET Yes; Max. 32 PROFINET Yes; Max. 32 PROFINET Yes; Max. 32 PROFINET
devices devices devices devices devices
- Number of connectable 128; In total, up to 256; In total, up to 256; In total, up to 512; In total, up to 512; In total, up to
IO Devices, max. 256 distributed 1 000 distributed 1 000 distributed 1 000 distributed 1 000 distributed
I/O devices can be I/O devices can be I/O devices can be I/O devices can be I/O devices can be
connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or
PROFINET PROFINET PROFINET PROFINET PROFINET
- Of which IO devices with IRT, max. 64 64 64 64 64
- Number of connectable 128 256 256 512 512
IO Devices for RT, max.
- of which in line, max. 128 256 256 512 512
- Number of IO Devices that can be 8; in total across all 8; in total across all 8; in total across all 8; in total across all 8; in total across all
simultaneously interfaces interfaces interfaces interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8 8 8
max.
- Updating times The minimum value of The minimum value of The minimum value of The minimum value of The minimum value of
the update time also the update time also the update time also the update time also the update time also
depends on depends on depends on depends on depends on
communication share communication share communication share communication share communication share
set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO,
on the number of IO on the number of IO on the number of IO on the number of IO on the number of IO
devices, and on the devices, and on the devices, and on the devices, and on the devices, and on the
quantity of configured quantity of configured quantity of configured quantity of configured quantity of configured
user data user data user data user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes Yes Yes
- Isochronous mode No No No No No
- IRT Yes Yes Yes Yes Yes; Minimum send
cycle of 250 µs
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Shared device Yes Yes Yes Yes Yes
- Number of IO Controllers with 4 4 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program Yes; per user program Yes; per user program
2. Interface
Interface types
• RJ 45 (Ethernet) Yes; X2 Yes; X2 Yes; X2 Yes; X2
• Number of ports 1 1 1 1
• integrated switch No No No No
Protocols
• IP protocol Yes; IPv4 Yes; IPv4 Yes; IPv4 Yes; IPv4
• PROFINET IO Controller Yes Yes Yes Yes
• PROFINET IO Device Yes Yes Yes Yes
• SIMATIC communication Yes Yes Yes Yes
• Open IE communication Yes; Optionally also Yes; Optionally also Yes; Optionally also Yes; Optionally also
encrypted encrypted encrypted encrypted
• Web server Yes Yes Yes Yes
• Media redundancy No No No No
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
PROFINET IO Controller
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode No No No No
- Direct data exchange No No No No 4
- IRT No No No No
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup No No No No
- Number of connectable 32; In total, up to 32; In total, up to 128; In total, up to 128; In total, up to
IO Devices, max. 1 000 distributed 1 000 distributed 1 000 distributed 1 000 distributed
I/O devices can be I/O devices can be I/O devices can be I/O devices can be
connected via AS-i, connected via AS-i, connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or PROFIBUS or PROFIBUS or
PROFINET PROFINET PROFINET PROFINET
- Number of connectable 32 32 128 128
IO Devices for RT, max.
- of which in line, max. 32 32 128 128
- Number of IO Devices that can be 8; in total across all 8; in total across all 8; in total across all 8; in total across all
simultaneously interfaces interfaces interfaces interfaces
activated/deactivated, max.
- Number of IO Devices per tool, 8 8 8 8
max.
- Updating times The minimum value of The minimum value of The minimum value of The minimum value of
the update time also the update time also the update time also the update time also
depends on depends on depends on depends on
communication share communication share communication share communication share
set for PROFINET IO, set for PROFINET IO, set for PROFINET IO, set for PROFINET IO,
on the number of on the number of on the number of on the number of
IO devices, and on the IO devices, and on the IO devices, and on the IO devices, and on the
quantity of configured quantity of configured quantity of configured quantity of configured
user data user data user data user data
PROFINET IO Device
Services
- PG/OP communication Yes Yes Yes Yes
- Isochronous mode No No No No
- IRT No No No No
- PROFIenergy Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Prioritized startup No No No No
- Shared device Yes Yes Yes Yes
- Number of IO Controllers with 4 4 4 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program Yes; per user program Yes; per user program Yes; per user program
- Asset management record Yes; per user program Yes; per user program Yes; per user program Yes; per user program
3. Interface
Interface types
• RJ 45 (Ethernet) Yes; X3
• RS 485 Yes; X3 Yes; X3
• Number of ports 1 1 1
• integrated switch No
Protocols
• IP protocol Yes; IPv4
• PROFINET IO Controller No
• PROFINET IO Device No
• PROFIBUS DP master Yes Yes
• PROFIBUS DP slave No No
• SIMATIC communication Yes Yes Yes
• Open IE communication Yes
• Web server Yes
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to 125; In total, up to
1 000 distributed 1 000 distributed
I/O devices can be I/O devices can be
4
connected via AS-i, connected via AS-i,
PROFIBUS or PROFIBUS or
PROFINET PROFINET
4. Interface
Interface types
• RS 485 Yes; X4
• Number of ports 1
Protocols
• PROFIBUS DP master Yes
• PROFIBUS DP slave No
• SIMATIC communication Yes
PROFIBUS DP master
• Number of DP slaves, max. 125; In total, up to
1 000 distributed
I/O devices can be
connected via AS-i,
PROFIBUS or
PROFINET
Protocols
Number of connections
• Number of connections, max. 96; via integrated 192; via integrated 256; via integrated 320; via integrated 384; via integrated
interfaces of the CPU interfaces of the CPU interfaces of the CPU interfaces of the CPU interfaces of the CPU
and connected and connected and connected and connected and connected
CPs / CMs CPs / CMs CPs / CMs CPs / CMs CPs / CMs
Redundancy mode
Media redundancy
- Media redundancy only via 1st interface only via 1st interface only via 1st interface only via 1st interface only via 1st interface
(X1) (X1) (X1) (X1) (X1)
- MRP Yes; MRP Yes; MRP Yes; MRP Yes; MRP Yes; MRP
Automanager Automanager Automanager Automanager Automanager
according to according to according to according to according to
IEC 62439-2 IEC 62439-2 IEC 62439-2 IEC 62439-2 IEC 62439-2
Edition 2.0, MRP Edition 2.0, MRP Edition 2.0, MRP Edition 2.0, MRP Edition 2.0, MRP
Manager; MRP Client Manager; MRP Client Manager; MRP Client Manager; MRP Client Manager; MRP Client
- MRP interconnection, supported Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring Yes; as MRP ring
node according to node according to node according to node according to node according to
IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0 IEC 62439-2 Edition 3.0
- MRPD Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT Yes; Requirement: IRT
- Switchover time on line break, typ. 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP, 200 ms; For MRP,
bumpless for MRPD bumpless for MRPD bumpless for MRPD bumpless for MRPD bumpless for MRPD
- Number of stations in the ring, 50 50 50 50 50
max.
SIMATIC communication
• S7 routing Yes Yes Yes Yes Yes
OPC UA
• OPC UA Client Yes Yes Yes Yes Yes
• OPC UA Server Yes; Data access Yes; Data access Yes; Data access Yes; Data access Yes; Data access
(read, write, subscribe), (read, write, subscribe), (read, write, subscribe), (read, write, subscribe), (read, write, subscribe),
method call, custom method call, custom method call, custom method call, custom method call, custom
address space address space address space address space address space
• Alarms and Conditions Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
Supported technology objects
Motion Control Yes; Note: The number Yes; Note: The number Yes; Note: The number Yes; Note: The number Yes; Note: The number
of technology objects of technology objects of technology objects of technology objects of technology objects
affects the cycle time affects the cycle time affects the cycle time affects the cycle time affects the cycle time
4
of the PLC program; of the PLC program; of the PLC program; of the PLC program; of the PLC program;
selection guide via the selection guide via the selection guide via the selection guide via the selection guide via the
TIA Selection Tool TIA Selection Tool TIA Selection Tool TIA Selection Tool TIA Selection Tool
• Number of available Motion Control 800 2 400 6 400 10 240 15 360
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40 40 40 40 40
- per positioning axis 80 80 80 80 80
- per synchronous axis 160 160 160 160 160
- per external encoder 80 80 80 80 80
- per output cam 20 20 20 20 20
- per cam track 160 160 160 160 160
- per probe 40 40 40 40 40
• Number of available Extended 40 120 192 256 512
Motion Control resources for
technology objects
• Required Extended Motion Control
resources
- per cam (1 000 points 2 2 2 2 2
and 50 segments)
- per cam (10 000 points 20 20 20 20 20
and 50 segments)
- for each set of kinematics 30 30 30 30 30
- Per leading axis proxy 3 3 3 3 3
Controller
• PID_Compact Yes; Universal PID Yes; Universal PID Yes; Universal PID Yes; Universal PID Yes; Universal PID
controller with controller with controller with controller with controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
• PID_3Step Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
for valves for valves for valves for valves for valves
• PID-Temp Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with Yes; PID controller with
integrated optimization integrated optimization integrated optimization integrated optimization integrated optimization
for temperature for temperature for temperature for temperature for temperature
Counting and measuring
• High-speed counter Yes Yes Yes Yes Yes
Standards, approvals, certificates
Highest safety class achievable
in safety mode
Probability of failure (for service
life of 20 years and repair time of
100 hours)
- Low demand mode: PFDavg in < 2.00E-05 < 2.00E-05 < 2.00E-05 < 2.00E-05 < 2.00E-05
accordance with SIL3
- High demand/continuous mode: < 1.00E-09 < 1.00E-09 < 1.00E-09 1/h < 1.00E-09 1/h < 1.00E-09
PFH in accordance with SIL3
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. 0 °C 0 °C 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C, 60 °C; Display: 50 °C,
at an operating at an operating at an operating at an operating at an operating
temperature of temperature of temperature of temperature of temperature of
typically 50 °C, the typically 50 °C, the typically 50 °C, the typically 50 °C, the typically 50 °C, the
display is switched off display is switched off display is switched off display is switched off display is switched off
• vertical installation, min. 0 °C 0 °C 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C, 40 °C; Display: 40 °C,
at an operating at an operating at an operating at an operating at an operating
temperature of temperature of temperature of temperature of temperature of
typically 40 °C, the typically 40 °C, the typically 40 °C, the typically 40 °C, the typically 40 °C, the
display is switched off display is switched off display is switched off display is switched off display is switched off
■ Technical specifications
Article number 6ES7511-1UK01- 6ES7515-2UM01- 6ES7516-3UN00- 6ES7517-3UP00- 6ES7518-4UP00-
0AB0 0AB0 0AB0 0AB0 0AB0
CPU 1511TF-1PN, CPU 1515TF-2 PN, CPU 1516TF-3 PN/DP, CPU 1517TF-3 PN/DP, CPU 1518TF-4 PN/DP,
225KB progr., 1MB data 750KB progr, 3MB data 1.5MB prog./5MB data 3MB prog., 8MB data 9MB Prog, 60MB data
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m; 5 000 m; 3 000 m; 3 000 m; 3 000 m;
max. Restrictions for Restrictions for Restrictions for Restrictions for Restrictions for
4
installation altitudes installation altitudes installation altitudes installation altitudes installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Configuration
Programming
Programming language
- LAD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- FBD Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe Yes; incl. failsafe
- STL Yes Yes Yes Yes Yes
- SCL Yes Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes Yes
Know-how protection
• User program protection/password Yes Yes Yes Yes Yes
protection
• Copy protection Yes Yes Yes Yes Yes
• Block protection Yes Yes Yes Yes Yes
Access protection
• protection of confidential Yes Yes Yes Yes Yes
configuration data
• Password for display Yes Yes Yes Yes Yes
• Protection level: Write protection Yes; Specific write Yes; Specific write Yes; Specific write Yes; Specific write Yes; Specific write
protection both for protection both for protection both for protection both for protection both for
Standard and for Standard and for Standard and for Standard and for Standard and for
Failsafe Failsafe Failsafe Failsafe Failsafe
• Protection level: Read/write Yes Yes Yes Yes Yes
protection
• Protection level: Write protection for Yes Yes Yes Yes Yes
Failsafe
• Protection level: Complete Yes Yes Yes Yes Yes
protection
Dimensions
Width 35 mm 70 mm 175 mm 175 mm 175 mm
Height 147 mm 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 430 g 830 g 1 978 g 1 978 g 1 988 g
■ Overview
• 16, 32 and 64-channel digital input modules
• Sinking and sourcing input versions available
• For flexible adaptation of the PLC to the corresponding task
• For subsequent expansion of the system with additional inputs
• 35 mm wide modules with parameters and diagnostic
functions
• 25 mm wide modules for use in tight spaces:
particularly economical, without parameters or diagnostic
functions
4
■ Technical specifications
Article number 6ES7521-1BH00- 6ES7521-1BL00- 6ES7521-1BH50- 6ES7521-1FH00- 6ES7521-7EH00-
0AB0 0AB0 0AA0 0AA0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500, DI 16 x
DI 16x24VDC HF DI 32x24VDC HF DI 16x24VDC SRC BA DI 16x230VAC BA 24...125V UC HF
General information
Product type designation DI 16x24VDC HF DI 32x24VDC HF DI 16x24VDC SRC BA DI 16x230VAC BA DI 16x24 ... 125 V UC
HF
Product function
4 • Isochronous mode
• Prioritized startup
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
Engineering with
• STEP 7 TIA Portal configurable/ V13 SP1 / - V13 SP1 / - V12 / V12 V12 / V12 V13 SP1 / -
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.3 / - V2.3 / - V2.3 / - V2.3 / -
GSD revision
Operating mode
• DI Yes Yes Yes Yes Yes
• Counter Yes Yes No No No
• Oversampling No No No
• MSI Yes Yes Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V
Reverse polarity protection Yes Yes
Digital inputs
Number of digital inputs 16 32 16 16 16
Digital inputs, parameterizable Yes Yes No No Yes
Source/sink input P-reading P-reading Sourcing P-reading Yes
Input characteristic curve in Yes
accordance with IEC 61131, type 1
Input characteristic curve in Yes Yes Yes Yes; At 24 V DC
accordance with IEC 61131, type 3
Digital input functions,
parameterizable
• Gate start/stop Yes Yes
• Freely usable digital input Yes Yes
Input voltage
• Rated value (DC) 24 V 24 V 24 V 24 V; 48 V, 125 V
- 24 V DC Yes Yes Yes Yes
• Rated value (AC) 230 V; 120/230 V AC, 24 V; 48 V, 125 V
50/60 Hz (50 - 60 Hz)
• for signal "0" -30 to +5 V -30 to +5 V -5 to +30V 0V AC to 40V AC -5 ... +5 V
• for signal "1" +11 to +30V +11 to +30V -11 to -30V 79V AC to 264V AC +11 ... +146 V
Input current
• for signal "1", typ. 2.5 mA 2.5 mA 4.5 mA 11 mA; At 230 V AC 3 mA; At 24 V DC
and 5.5 mA at
120 V AC
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.05 / 0.1 / 0.4 / Yes; 0.05 / 0.1 / 0.4 / No No Yes; 0.05 / 0.1 / 0.4 /
1.6 / 3.2 / 12.8 / 20 ms 1.6 / 3.2 / 12.8 / 20 ms 1.6 / 3.2 / 12.8 / 20 ms
parameterizable
with DC, 20 ms fixed
with AC
for interrupt inputs
- parameterizable Yes Yes No No Yes
for technological functions
- parameterizable Yes Yes No No No
Encoder
Connectable encoders
• 2-wire sensor Yes Yes Yes Yes Yes
- permissible quiescent current 1.5 mA 1.5 mA 1.5 mA 2 mA 1.5 mA
(2-wire sensor), max.
■ Technical specifications
Article number 6ES7521-1BH00- 6ES7521-1BL00- 6ES7521-1BH50- 6ES7521-1FH00- 6ES7521-7EH00-
0AB0 0AB0 0AA0 0AA0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500, DI 16 x
DI 16x24VDC HF DI 32x24VDC HF DI 16x24VDC SRC BA DI 16x230VAC BA 24...125V UC HF
Isochronous mode
Filtering and processing time (TCI), min. 80 µs; At 50 μs 80 µs; At 50 μs
filter time filter time
Bus cycle time (TDP), min. 250 µs 250 µs
Interrupts/diagnostics/
status information 4
Diagnostics function Yes Yes No No Yes
Alarms
• Diagnostic alarm Yes Yes No No Yes
• Hardware interrupt Yes Yes No No Yes
Diagnoses
• Monitoring the supply voltage Yes Yes No No No
• Wire-break Yes; to I < 350 µA Yes; to I < 350 µA No No Yes; To I < 550 µA
• Short-circuit No No No No No
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• Monitoring of the supply voltage Yes; green LED Yes; green LED No No No
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• for channel diagnostics Yes; red LED Yes; red LED No No Yes; red LED
• for module diagnostics Yes; red LED Yes; red LED No Yes; red LED Yes; red LED
Potential separation
Potential separation channels
• between the channels and Yes Yes Yes Yes Yes
backplane bus
Standards, approvals, certificates
Suitable for safety functions No No No No No
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -30 °C; From FS05 -30 °C; From FS05 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C 60 °C 60 °C 60 °C 60 °C
• vertical installation, min. -30 °C; From FS05 -30 °C; From FS05 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C 40 °C 40 °C 40 °C 40 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions
max. for installation altitudes for installation altitudes for installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Dimensions
Width 35 mm 35 mm 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 240 g 260 g 230 g 300 g 240 g
■ Technical specifications
Article number 6ES7521-1BP00-0AA0 Article number 6ES7521-1BP00-0AA0
S7-1500, DI 64x24VDC SNK/SRC BA S7-1500, DI 64x24VDC SNK/SRC BA
General information Interrupts/diagnostics/
Product type designation DI 64x24VDC BA status information
Product function Diagnostics function No
• Isochronous mode No Alarms
• Prioritized startup No • Diagnostic alarm No
4 Engineering with
• STEP 7 TIA Portal configurable/ V16 with HSP 0319 / V17
• Hardware interrupt
Diagnoses
No
■ Technical specifications
Article number 6ES7521-1BH10-0AA0 6ES7521-1BL10-0AA0
S7-1500, DI 16x24VDC BA S7-1500, DI 32x24VDC BA
General information
Product type designation DI 16 x 24 V DC BA DI 32x24VDC BA
Product function
• Isochronous mode No No
• Prioritized startup Yes Yes
Engineering with
• STEP 7 TIA Portal configurable/ V13 / V13 V13 / V13
4
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.3 / -
GSD revision
Operating mode
• DI Yes Yes
• Counter No No
• MSI Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V
Digital inputs
Number of digital inputs 16 32
Digital inputs, parameterizable No No
Source/sink input P-reading P-reading
Input characteristic curve in Yes Yes
accordance with IEC 61131, type 3
Input voltage
• Rated value (DC) 24 V 24 V
- 24 V DC Yes Yes
• for signal "0" -30 to +5 V -30 to +5 V
• for signal "1" +11 to +30V +11 to +30V
Input current
• for signal "1", typ. 2.7 mA 2.7 mA
Input delay (for rated value
of input voltage)
for standard inputs
- parameterizable No No
for interrupt inputs
- parameterizable No No
for technological functions
- parameterizable No No
Encoder
Connectable encoders
• 2-wire sensor Yes Yes
- permissible quiescent current 1.5 mA 1.5 mA
(2-wire sensor), max.
■ Technical specifications
Article number 6ES7521-1BH10-0AA0 6ES7521-1BL10-0AA0
S7-1500, DI 16x24VDC BA S7-1500, DI 32x24VDC BA
Interrupts/diagnostics/
status information
Diagnostics function No No
Alarms
• Diagnostic alarm No No
4 • Hardware interrupt
Diagnoses
No No
■ Overview
• 8, 32, 16 and 64-channel digital output modules
• Sinking and sourcing output versions available
• For flexible adaptation of the PLC to the corresponding task
• For subsequent expansion of the system with additional
outputs
• High Feature modules with parameters and diagnostic
functions
• 25 mm wide modules for use in tight spaces: particularly
economical, without parameters or diagnostic functions
4
■ Technical specifications
Article number 6ES7522-1BH01-0AB0 6ES7522-1BL01-0AB0 6ES7522-1BF00-0AB0 6ES7522-5EH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 16x24V DC/0.5A HF DQ 32x24VDC/0.5A HF DQ 8x24VDC/2A HF DQ 16x24...48VUC/
125VDC/0.5A ST
General information
Product type designation DQ 16x24VDC/0.5A HF DQ 32x24VDC/0.5A HF DQ 8x24VDC/2A HF DQ 16x24 ... 48 V UC/
125 V DC/0.5 A ST
Product function
4 • Isochronous mode
• Prioritized startup
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Engineering with
• STEP 7 TIA Portal configurable/ V13 SP1 / - V13 SP1 / - V13 SP1 / - V13 SP1 / -
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.3 / - V2.3 / - V2.3 / -
GSD revision
Operating mode
• DQ Yes Yes Yes Yes
• DQ with energy-saving function No No Yes; with an application No
• PWM No No Yes No
• Cam control (switching at No No No No
comparison values)
• Oversampling No No No No
• MSO Yes Yes Yes Yes
• Integrated operating cycle counter Yes Yes Yes No
Supply voltage
Rated value (DC) 24 V 24 V 24 V
Reverse polarity protection Yes; through internal Yes; through internal Yes; through internal
protection with 7 A per group protection with 7 A per group protection with 10 A per group
Digital outputs
Type of digital output Transistor Transistor Transistor Transistor
Number of digital outputs 16 32 8 16
Current-sinking Yes
Current-sourcing Yes Yes Yes Yes
Digital outputs, parameterizable Yes Yes Yes Yes
Short-circuit protection Yes; Clocked electronically Yes; Clocked electronically Yes
Limitation of inductive shutdown L+ (-53 V) L+ (-53 V) -17 V 200 V (suppressor diode)
voltage to
Controlling a digital input Yes Yes Yes Yes
Digital output functions,
parameterizable
• Freely usable digital output Yes
• PWM output Yes
- Number, max. 2
Switching capacity of the outputs
• with resistive load, max. 0.5 A 0.5 A 0.5 A
• on lamp load, max. 5W 5W 10 W 40 W; At 125 V DC, 10 W at
48 V UC, 5 W at 24 V UC
Load resistance range
• lower limit 48 Ω 48 Ω 12 Ω
• upper limit 12 kΩ 12 kΩ 4 kΩ
Output voltage
• Type of output voltage DC DC DC UC
• for signal "1", min. L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-1.0 V)
Output current
• for signal "1" rated value 0.5 A 0.5 A 2A 0.5 A
• for signal "0" residual current, max. 0.5 mA 0.5 mA 0.5 mA
■ Technical specifications
Article number 6ES7522-1BH01-0AB0 6ES7522-1BL01-0AB0 6ES7522-1BF00-0AB0 6ES7522-5EH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 16x24V DC/0.5A HF DQ 32x24VDC/0.5A HF DQ 8x24VDC/2A HF DQ 16x24...48VUC/
125VDC/0.5A ST
Output delay with resistive load
• "0" to "1", typ. 80 µs
• "0" to "1", max. 100 µs 100 µs 100 µs 5 ms
• "1" to "0", typ. 300 µs
• "1" to "0", max. 500 µs 500 µs 500 µs 5 ms 4
Parallel switching of two outputs
• for logic links Yes Yes Yes Yes
• for uprating No No No No
• for redundant control of a load Yes Yes Yes Yes
Switching frequency
• with resistive load, max. 100 Hz 100 Hz 100 Hz; With PWM 25 Hz
operation: 500 Hz
• with inductive load, max. 0.5 Hz; According to 0.5 Hz; According to 0.5 Hz; According to 0.5 Hz
IEC 60947-5-1, DC-13 IEC 60947-5-1, DC-13 IEC 60947-5-1, DC-13;
max. 500 Hz with PWM
operation only with external
circuit; see additional
description in the manual
• on lamp load, max. 10 Hz 10 Hz 10 Hz 10 Hz
Total current of the outputs
• Current per channel, max. 0.5 A; see additional 0.5 A; see additional 2 A; see additional 0.5 A
description in the manual description in the manual description in the manual
• Current per group, max. 4 A; see additional 4 A; see additional 8 A; see additional 0.5 A
description in the manual description in the manual description in the manual
• Current per module, max. 8 A; see additional 16 A; see additional 16 A; see additional 8A
description in the manual description in the manual description in the manual
Isochronous mode
Execution and activation time (TCO), 70 µs 70 µs
min.
Bus cycle time (TDP), min. 250 µs 250 µs
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes Yes No
Substitute values connectable Yes Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes Yes No
• Maintenance interrupt Yes Yes Yes No
Diagnoses
• Monitoring the supply voltage Yes Yes Yes No
• Wire-break Yes Yes No No
• Short-circuit Yes Yes Yes No
• Group error Yes Yes Yes
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• MAINT LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
• Monitoring of the supply voltage Yes; green LED Yes; green LED Yes; green LED No
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• for channel diagnostics Yes; red LED Yes; red LED Yes; red LED No
• for module diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
Potential separation
Potential separation channels
• between the channels and Yes Yes Yes Yes
backplane bus
■ Technical specifications
Article number 6ES7522-1BH01-0AB0 6ES7522-1BL01-0AB0 6ES7522-1BF00-0AB0 6ES7522-5EH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 16x24V DC/0.5A HF DQ 32x24VDC/0.5A HF DQ 8x24VDC/2A HF DQ 16x24...48VUC/
125VDC/0.5A ST
Standards, approvals, certificates
Suitable for safety functions No No No No
Suitable for safety-related tripping of Yes; From FS02 Yes; From FS02 Yes; From FS03 Yes; From FS02
standard modules
■ Technical specifications
Article number 6ES7522-5HF00-0AB0 6ES7522-5HH00-0AB0 6ES7522-5FF00-0AB0 6ES7522-5FH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 8x230VAC/5A ST DQ 16x230VAC/2A ST DQ 8x230VAC/2A ST DQ 16x230VAC/1A ST
(Relay) (Relay) (Triac) (Triac)
Digital outputs
Type of digital output Relays Relays Triac Triac
Number of digital outputs 8 16 8 16
Current-sinking Yes Yes Yes
Current-sourcing Yes Yes Yes Yes 4
Digital outputs, parameterizable Yes Yes Yes Yes
Short-circuit protection No No No No
Controlling a digital input Yes; possible Yes
Switching capacity of the outputs
• with resistive load, max. 2A 1A
• on lamp load, max. 1 500 W; 50 W (230 V AC), 50 W 50 W
10 000 operating cycles 5 W (24 V DC)
• Low energy/fluorescent lamps with 10x 58 W
electronic control gear (25 000 operating cycles)
• Fluorescent tubes, conventionally 1x 58 W
compensated (25 000 operating cycles)
• Fluorescent tubes, uncompensated 10x 58 W
(25 000 operating cycles)
Output voltage
• Type of output voltage AC AC
• for signal "1", min. L1 (-1.5 V) at maximum L1 (-1.5 V) at maximum
output current; output current;
L1 (-8.5 V) at minimum L1 (-8.5 V) at minimum
output current output current
Output current
• for signal "1" rated value 5A 2A 2A 1A
• for signal "0" residual current, max. 0A 0A 2 mA 2 mA
Output delay with resistive load
• "0" to "1", max. 1 AC cycle 1 AC cycle
• "1" to "0", max. 1 AC cycle 1 AC cycle
Parallel switching of two outputs
• for logic links Yes Yes No No
• for uprating No No No No
• for redundant control of a load Yes Yes Yes Yes
Switching frequency
• with resistive load, max. 2 Hz 1 Hz 10 Hz 10 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz
• on lamp load, max. 2 Hz 1 Hz 1 Hz 1 Hz
Total current of the outputs
• Current per channel, max. 8 A; see additional 2 A; see additional 2 A; see additional 1 A; see additional
description in the manual description in the manual description in the manual description in the manual
• Current per group, max. 8 A; see additional 4 A; see additional 2 A; see additional 2 A; see additional
description in the manual description in the manual description in the manual description in the manual
• Current per module, max. 64 A; see additional 32 A; see additional 10 A; see additional 10 A; see additional
description in the manual description in the manual description in the manual description in the manual
■ Technical specifications
Article number 6ES7522-5HF00-0AB0 6ES7522-5HH00-0AB0 6ES7522-5FF00-0AB0 6ES7522-5FH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 8x230VAC/5A ST DQ 16x230VAC/2A ST DQ 8x230VAC/2A ST DQ 16x230VAC/1A ST
(Relay) (Relay) (Triac) (Triac)
Relay outputs
• Number of relay outputs 8 16
• Rated supply voltage of relay 24 V 24 V
coil L+ (DC)
• external protection for relay outputs With miniature circuit breaker Miniature circuit breaker
with characteristic B for: B10 / B16
cos ϕ 1.0: 600 A
cos ϕ 0.5 ... 0.7: 900 A
with 8 A Diazed fuse:
1 000 A
• Contact connection (internal) No No
• Number of operating cycles, max. 4 000 000; see additional see additional description
description in the manual in the manual
• Relay approved acc. to UL 508 Yes; 250 V AC/5 A g.p.; No
120 V AC TV-4 tungsten;
A300, R300
Switching capacity of contacts
- with inductive load, max. see additional description 2 A; see additional
in the manual description in the manual
- with resistive load, max. see additional description 2 A; see additional
in the manual description in the manual
Interrupts/diagnostics/
status information
Diagnostics function Yes No No
Substitute values connectable Yes Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes No No
• Maintenance interrupt Yes No No
Diagnoses
• Monitoring the supply voltage Yes Yes No No
• Wire-break No No No No
• Short-circuit No No No No
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• MAINT LED Yes; Yellow LED Yes; Yellow LED
• Monitoring of the supply voltage Yes; green LED Yes; green LED No No
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• for channel diagnostics No No No No
• for module diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
Potential separation
Potential separation channels
• between the channels and Yes Yes Yes Yes
backplane bus
Standards, approvals, certificates
Suitable for safety functions No No No No
Suitable for safety-related tripping Yes; From FS03 Yes; From FS02
of standard modules
Highest safety class achievable
for safety-related tripping
of standard modules
• Performance level according to PL c PL c
ISO 13849-1
• Category according to ISO 13849-1 Cat. 2 Cat. 2
• SILCL according to IEC 62061 SILCL 1 SILCL 1
■ Technical specifications
Article number 6ES7522-5HF00-0AB0 6ES7522-5HH00-0AB0 6ES7522-5FF00-0AB0 6ES7522-5FH00-0AB0
S7-1500, S7-1500, S7-1500, S7-1500,
DQ 8x230VAC/5A ST DQ 16x230VAC/2A ST DQ 8x230VAC/2A ST DQ 16x230VAC/1A ST
(Relay) (Relay) (Triac) (Triac)
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -30 °C; From FS03 -25 °C; From FS02 0 °C 0 °C
• horizontal installation, max.
• vertical installation, min.
60 °C
-30 °C; From FS03
60 °C
-25 °C; From FS02
60 °C
0 °C
60 °C
0 °C
4
• vertical installation, max. 40 °C 40 °C 40 °C 40 °C
Dimensions
Width 35 mm 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 350 g 350 g 290 g 310 g
■ Technical specifications
Article number 6ES7522-1BP00-0AA0 6ES7522-1BP50-0AA0
S7-1500, DQ 64x24VDC/0.3A BA S7-1500, DQ 64x24VDC/0.3A SNK BA
Output voltage
• Type of output voltage DC DC
• for signal "1", min. L+ (-0.8 V) M+ (0.5 V)
Output current
• for signal "1" rated value 0.3 A 0.3 A
■ Technical specifications
Article number 6ES7522-1BP00-0AA0 6ES7522-1BP50-0AA0
S7-1500, DQ 64x24VDC/0.3A BA S7-1500, DQ 64x24VDC/0.3A SNK BA
Standards, approvals, certificates
Suitable for safety functions No No
Suitable for safety-related tripping Yes; From FS01 No
of standard modules
Highest safety class achievable for
4
safety-related tripping of standard
modules
• Performance level according to PL d
ISO 13849-1
• Category according to ISO 13849-1 Cat. 3
• SILCL according to IEC 62061 SILCL 2
Ambient conditions
Ambient temperature during opera-
tion
• horizontal installation, min. -30 °C -30 °C
• horizontal installation, max. 60 °C 60 °C
• vertical installation, min. -30 °C -30 °C
• vertical installation, max. 40 °C 40 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
Dimensions
Width 35 mm 35 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 270 g 270 g
Other
Note: Please order cable and connection modules separately Please order cable and connection modules separately
■ Technical specifications
Article number 6ES7522-1BH10-0AA0 6ES7522-1BL10-0AA0
S7-1500, DQ 16x24VDC/0.5A BA S7-1500, DQ 32x24VDC/0.5A BA
Digital outputs
Type of digital output Transistor Transistor
Number of digital outputs 16 32
Current-sourcing Yes Yes
Digital outputs, parameterizable No No
4 Short-circuit protection
Limitation of inductive shutdown
Yes
L+ (-53 V)
Yes
L+ (-53 V)
voltage to
Controlling a digital input Yes Yes
Switching capacity of the outputs
• with resistive load, max. 0.5 A 0.5 A
• on lamp load, max. 5W 5W
Load resistance range
• lower limit 48 Ω 48 Ω
• upper limit 12 kΩ 12 kΩ
Output voltage
• Type of output voltage DC DC
• for signal "1", min. L+ (-0.8 V) L+ (-0.8 V)
Output current
• for signal "1" rated value 0.5 A 0.5 A
• for signal "0" residual current, max. 0.5 mA 0.5 mA
Output delay with resistive load
• "0" to "1", max. 100 µs 100 µs
• "1" to "0", max. 500 µs 500 µs
Parallel switching of two outputs
• for logic links Yes Yes
• for uprating No No
• for redundant control of a load Yes Yes
Switching frequency
• with resistive load, max. 100 Hz 100 Hz
• with inductive load, max. 0.5 Hz; According to IEC 60947-5-1, DC-13 0.5 Hz; According to IEC 60947-5-1, DC-13
• on lamp load, max. 10 Hz 10 Hz
Total current of the outputs
• Current per channel, max. 0.5 A; see additional description in the manual 0.5 A; see additional description in the manual
• Current per group, max. 4 A; see additional description in the manual 4 A; see additional description in the manual
• Current per module, max. 8 A; see additional description in the manual 16 A; see additional description in the manual
Interrupts/diagnostics/
status information
Diagnostics function No No
Substitute values connectable No No
Alarms
• Diagnostic alarm No No
• Maintenance interrupt No No
Diagnoses
• Monitoring the supply voltage No No
• Wire-break No No
• Short-circuit No No
• Group error No No
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED
• Monitoring of the supply voltage Yes; green LED Yes; green LED
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED
• for channel diagnostics No No
• for module diagnostics No No
■ Technical specifications
Article number 6ES7522-1BH10-0AA0 6ES7522-1BL10-0AA0
S7-1500, DQ 16x24VDC/0.5A BA S7-1500, DQ 32x24VDC/0.5A BA
Potential separation
Potential separation channels
• between the channels and Yes Yes
backplane bus
Standards, approvals, certificates
Suitable for safety functions
Suitable for safety-related tripping of
No
Yes; From FS02
No
Yes; From FS02 4
standard modules
Highest safety class achievable for
safety-related tripping of standard
modules
• Performance level according to PL d PL d
ISO 13849-1
• Category according to ISO 13849-1 Cat. 3 Cat. 3
• SILCL according to IEC 62061 SILCL 2 SILCL 2
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for installation altitudes > 2 000 m, 5 000 m; Restrictions for installation altitudes > 2 000 m,
max. see manual see manual
Dimensions
Width 25 mm 25 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 230 g 280 g
Other
Note: Supplied incl. 40-pole push-in front connectors Supplied incl. 40-pole push-in front connectors
■ Overview
• 16 digital inputs and 16 digital outputs (25 mm wide)
• 32 digital inputs, sinking/sourcing / 32 digital outputs,
sourcing (35 mm wide)
• For flexible adaptation of the PLC to the corresponding task
• For subsequent expansion of the system with additional inputs
and outputs
• For use in the tightest spaces: particularly economical,
4 without parameters or diagnostic functions
■ Technical specifications
Article number 6ES7523-1BL00-0AA0 6ES7523-1BP50-0AA0
S7-1500, DI 16x24VDC/DQ 16x24VDC/0.5A BA S7-1500, DI 32x24VDC/DQ 32x24VDC/0.3A BA
General information
Product type designation DI 16x24VDC / DQ16x24VDC/0.5A BA DI 32 x 24 V DC / DQ 32 x 24 V DC/0.3A SNK BA
Product function
• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
• Isochronous mode No No
• Prioritized startup
Engineering with
Yes No
4
• STEP 7 TIA Portal configurable/ V13 / V13 V16 with HSP 0319 / V17
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.35 / -
GSD revision
Operating mode
• DI Yes Yes
• Counter No No
• DQ Yes Yes
• DQ with energy-saving function No No
• PWM No No
• Cam control No
(switching at comparison values)
• Oversampling No No
• MSI Yes Yes
• MSO Yes Yes
• Integrated operating cycle counter No
Supply voltage
Rated value (DC) 24 V 24 V
Reverse polarity protection Yes; through internal protection with 7 A per group Yes; Through internal protection with 4 A per group
Digital inputs
Number of digital inputs 16 32
Digital inputs, parameterizable No No
Source/sink input P-reading Yes
Input characteristic curve in Yes Yes
accordance with IEC 61131, type 3
Number of simultaneously
controllable inputs
• Number of simultaneously 32
controllable inputs
horizontal installation
- up to 60 °C, max. 32
vertical installation
- up to 40 °C, max. 16
Input voltage
• Rated value (DC) 24 V 24 V
• for signal "0" -30 to +5 V -5 ... +5 V (reference potential is COM)
• for signal "1" +11 to +30V -11 ... -30 V; +11 ... +30 V (reference potential is COM)
Input current
• for signal "1", typ. 2.7 mA 2.7 mA
Input delay (for rated value of input
voltage)
for standard inputs
- parameterizable No No
for interrupt inputs
- parameterizable No No
for technological functions
- parameterizable No
■ Technical specifications
Article number 6ES7523-1BL00-0AA0 6ES7523-1BP50-0AA0
S7-1500, DI 16x24VDC/DQ 16x24VDC/0.5A BA S7-1500, DI 32x24VDC/DQ 32x24VDC/0.3A BA
Digital outputs
Type of digital output Transistor Transistor
Number of digital outputs 16 32
Current-sinking Yes
Current-sourcing Yes No
■ Technical specifications
Article number 6ES7523-1BL00-0AA0 6ES7523-1BP50-0AA0
S7-1500, DI 16x24VDC/DQ 16x24VDC/0.5A BA S7-1500, DI 32x24VDC/DQ 32x24VDC/0.3A BA
Interrupts/diagnostics/
status information
Diagnostics function No No
Substitute values connectable No No
Alarms
• Diagnostic alarm
• Maintenance interrupt
No
No
No
No 4
• Hardware interrupt No No
Diagnoses
• Monitoring the supply voltage No No
• Wire-break No No
• Short-circuit No No
• Group error No No
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED
• MAINT LED No
• Monitoring of the supply voltage Yes; green LED Yes; via SIMATIC TOP connect connection module
(PWR-LED)
• Channel status display Yes; green LED Yes; via SIMATIC TOP connect connection module
• for channel diagnostics No No
• for module diagnostics No No
Potential separation
Potential separation channels
• between the channels and Yes Yes
backplane bus
Standards, approvals, certificates
Suitable for safety-related tripping Yes; From FS03
of standard modules
Highest safety class achievable for
safety-related tripping of standard
modules
• Performance level according to PL d
ISO 13849-1
• Category according to ISO 13849-1 Cat. 3
• SILCL according to IEC 62061 SILCL 2
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -30 °C
• horizontal installation, max. 60 °C
• vertical installation, min. -30 °C
• vertical installation, max. 40 °C
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for installation altitudes > 2 000 m, 5 000 m
max. see manual
Dimensions
Width 25 mm 35 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 280 g 250 g
Other
Note: Supplied incl. 40-pole push-in front connectors Please order cable and connection modules separately
■ Technical specifications
Article number 6AG1521-1BH00- 6AG1521-1BL00- 6AG1521-1BH50- 6AG1521-1FH00- 6AG1521-7EH00-
7AB0 7AB0 7AA0 7AA0 7AB0
Based on 6ES7521-1BH00- 6ES7521-1BL00- 6ES7521-1BH50- 6ES7521-1FH00- 6ES7521-7EH00-
0AB0 0AB0 0AA0 0AA0 0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
DI 16X24VDC HF DI 32X24VDC HF DI 16X24VDC SRC BA DI 16X230VAC BA DI 16X48VUC/125VDC
HF
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl.
condensation/frost) condensation/frost) condensation/frost) condensation/frost) condensation/frost)
• horizontal installation, max. 70 °C; = Tmax 70 °C; = Tmax; 70 °C; = Tmax; 70 °C; = Tmax; 70 °C; = Tmax;
> +60 °C number of > +60 °C number of > +60 °C number of see Derating BasedOn
simultaneously simultaneously simultaneously (e.g. manual),
controllable inputs controllable inputs controllable inputs additionally
max. 16 max. 8 max. 8 Tmax > 60 °C max.
4 inputs (no adjacent
points)
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
• vertical installation, max. 40 °C; = Tmax 40 °C; = Tmax 40 °C; = Tmax 40 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
// // //
Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K)
at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) (+2 000 m ... +3 500 m) (+2 000 m ... +3 500 m)
// // //
Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K)
at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
■ Technical specifications
Article number 6AG1521-1BH00- 6AG1521-1BL00- 6AG1521-1BH50- 6AG1521-1FH00- 6AG1521-7EH00-
7AB0 7AB0 7AA0 7AA0 7AB0
Based on 6ES7521-1BH00- 6ES7521-1BL00- 6ES7521-1BH50- 6ES7521-1FH00- 6ES7521-7EH00-
0AB0 0AB0 0AA0 0AA0 0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
DI 16X24VDC HF DI 32X24VDC HF DI 16X24VDC SRC BA DI 16X230VAC BA DI 16X48VUC/125VDC
HF
Relative humidity
• With condensation, tested in
accordance with IEC 60068-2-38,
max.
100 %; RH incl.
condensation/frost
(no commissioning
100 %; RH incl.
condensation/frost
(no commissioning
100 %; RH incl.
condensation/frost
(no commissioning
100 %; RH incl.
condensation/frost
(no commissioning
100 %; RH incl.
condensation / frost
(no commissioning
4
under condensation under condensation under condensation under condensation in bedewed state),
conditions) conditions) conditions) conditions) horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot fungus and dry rot fungus and dry rot fungus and dry rot fungus and dry rot
spores (with the spores (with the spores (with the spores (with the spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4
according to EN 60721-3-3 (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt
spray acc. to spray acc. to spray acc. to spray acc. to spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl.
according to EN 60721-3-3 sand, dust, * sand, dust, * sand, dust, * sand, dust, * sand, dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold
according to EN 60721-3-6 and fungal spores and fungal spores and fungal spores and fungal spores and fungal spores
(excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna);
Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3
according to EN 60721-3-6 (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt
spray acc. to spray acc. to spray acc. to spray acc. to spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl.
according to EN 60721-3-6 sand, dust; * sand, dust; * sand, dust; * sand, dust; * sand, dust; *
■ Technical specifications
Article number 6AG1521-1BH00- 6AG1521-1BL00- 6AG1521-1BH50- 6AG1521-1FH00- 6AG1521-7EH00-
7AB0 7AB0 7AA0 7AA0 7AB0
Based on 6ES7521-1BH00- 6ES7521-1BL00- 6ES7521-1BH50- 6ES7521-1FH00- 6ES7521-7EH00-
0AB0 0AB0 0AA0 0AA0 0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
DI 16X24VDC HF DI 32X24VDC HF DI 16X24VDC SRC BA DI 16X230VAC BA DI 16X48VUC/125VDC
HF
Usage in industrial process
4
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding (excluding (excluding (excluding (excluding
trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group
process, measuring and control A/B (excluding A/B (excluding A/B (excluding A/B (excluding A/B (excluding
systems acc. to ANSI/ISA-71.04 trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene;
harmful gas harmful gas harmful gas harmful gas harmful gas
concentrations up concentrations up concentrations up concentrations up concentrations up
to the limits of to the limits of to the limits of to the limits of to the limits of
EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class
3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible);
level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray)
and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug * The supplied plug * The supplied plug * The supplied plug * The supplied plug
environmental conditions acc. to covers must remain in covers must remain in covers must remain in covers must remain in covers must remain in
EN 60721, EN 60654-4 and place over the unused place over the unused place over the unused place over the unused place over the unused
ANSI/ISA-71.04 interfaces during interfaces during interfaces during interfaces during interfaces during
operation! operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of
MIL-I-46058C, Amendment 7 coating possible coating possible coating possible coating possible coating possible
during service life during service life during service life during service life during service life
• Qualification and Performance Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal
of Electrical Insulating Compound coating, Class A coating, Class A coating, Class A coating, Class A coating, Class A
for Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1522-1BF00-7AB0 6AG1522-1BH01-7AB0 6AG1522-1BL01-7AB0 6AG1522-5EH00-7AB0
Based on 6ES7522-1BF00-0AB0 6ES7522-1BH01-0AB0 6ES7522-1BL01-0AB0 6ES7522-5EH00-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
DQ 8X24VDC/2A HF DQ 16X24VDC/0.5A HF DQ 32X24VDC/0.5A HF DQ 16x48VUC/125VDC ST
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl. -40 °C; = Tmin (incl.
condensation/frost) condensation/frost) condensation/frost) condensation/frost)
• horizontal installation, max. 70 °C; = Tmax; > +60 °C 70 °C; = Tmax; see Derating 70 °C; = Tmax; see Derating 70 °C; = Tmax; > +60 °C
Number of simultaneously BasedOn (e.g. manual), BasedOn (e.g. manual), max. 0.25 A per output
controllable outputs additionally Tmax > 60 °C additionally Tmax > 60 °C
max. 8x 0.5 A, max. total max. aggregate current 2 A max. aggregate current 2 A
current per group 2 A per group per group
• vertical installation, min. -40 °C; = Tmin
• vertical installation, max. 40 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m)
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation / frost condensation / frost condensation / frost
max. (no commissioning (no commissioning in (no commissioning in (no commissioning in
under condensation bedewed state), bedewed state), bedewed state),
conditions) horizontal installation horizontal installation horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
■ Technical specifications
Article number 6AG1522-1BF00-7AB0 6AG1522-1BH01-7AB0 6AG1522-1BL01-7AB0 6AG1522-5EH00-7AB0
Based on 6ES7522-1BF00-0AB0 6ES7522-1BH01-0AB0 6ES7522-1BL01-0AB0 6ES7522-5EH00-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
DQ 8X24VDC/2A HF DQ 16X24VDC/0.5A HF DQ 32X24VDC/0.5A HF DQ 16x48VUC/125VDC ST
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
■ Technical specifications
Article number 6AG1522-5HH00-7AB0 6AG1522-5HF00-2AB0 6AG1522-5FF00-7AB0 6AG1522-5FH00-7AB0
Based on 6ES7522-5HH00-0AB0 6ES7522-5HF00-0AB0 6ES7522-5FF00-0AB0 6ES7522-5FH00-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
16DQ 230VAC 2A RLY DQ 8X230VAC/5A ST DQ 8X230VAC/2A ST 16DQ 230VAC 1A ST TRIAC
(RELAY) (TRIAC)
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin
(incl. condensation/frost);
-25 °C; = Tmin
(incl. condensation/frost)
-40 °C; = Tmin
(incl. condensation/frost)
-40 °C; = Tmin
(incl. condensation/frost); 4
start-up @ -25 °C start-up @ -25 °C
• horizontal installation, max. 70 °C; = Tmax; see Derating 60 °C; = Tmax 70 °C; = Tmax; > +60 °C 70 °C; = Tmax; see Derating
BasedOn (e.g. manual), number of simultaneously BasedOn (e.g. manual),
additionally Tmax > 60 °C controllable outputs additionally Tmax > 60 °C
max. 8 outputs max. 8x 0.25 A, max. 4 A aggregate current
(no adjacent points) max. total current 2 A per module, max. 0.25 A per
output
• vertical installation, min. -40 °C; = Tmin; -25 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin;
Startup @ -25 °C Startup @ -25 °C
• vertical installation, max. 40 °C 40 °C; = Tmax 40 °C; = Tmax 60 °C
Altitude during operation relating
to sea level
• Installation altitude above sea level, 2 000 m 2 000 m 2 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation / frost (no condensation/frost (no condensation/frost (no condensation / frost (no
max. commissioning in bedewed commissioning under commissioning under commissioning in bedewed
state), horizontal installation condensation conditions) condensation conditions) state), horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1522-5HH00-7AB0 6AG1522-5HF00-2AB0 6AG1522-5FF00-7AB0 6AG1522-5FH00-7AB0
Based on 6ES7522-5HH00-0AB0 6ES7522-5HF00-0AB0 6ES7522-5FF00-0AB0 6ES7522-5FH00-0AB0
SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500 SIPLUS S7-1500
16DQ 230VAC 2A RLY DQ 8X230VAC/5A ST DQ 8X230VAC/2A ST 16DQ 230VAC 1A ST TRIAC
(RELAY) (TRIAC)
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
■ Overview
• 4, 8 or 16-channel analog input modules
• Optionally with extremely short conversion times
• For the connection of analog sensors without additional
amplifiers
• Even solves more complex automation tasks
4
and shield terminal;
For 25 mm modules; 6ES7592-1BM00-0XA0 4 units, spare part (one shield
including cable ties and set supplied with the module).
individual labeling strips;
push-in terminal 40-pin; Shield terminal element 6ES7590-5BA00-0AA0
spare part 10 units; spare part
DIN A4 labeling sheets SIMATIC Manual Collection 6ES7998-8XC01-8YE0
For 35 mm modules; 6ES7592-2AX00-0AA0 Electronic manuals on DVD,
10 sheets with 10 labeling multilingual:
strips each for I/O modules; LOGO!, SIMADYN,
perforated, Al gray SIMATIC bus components,
For 25 mm modules; 6ES7592-1AX00-0AA0 SIMATIC C7,
10 sheets with 20 labeling SIMATIC distributed I/O,
strips each for I/O modules; SIMATIC HMI, SIMATIC sensors,
perforated, Al gray SIMATIC NET, SIMATIC PC-based
automation, SIMATIC PCS 7,
U connector 6ES7590-0AA00-0AA0 SIMATIC PG/PC, SIMATIC S7,
SIMATIC software, SIMATIC TDC
5 units; spare part
SIMATIC Manual Collection 6ES7998-8XC01-8YE2
Universal front door for update service for 1 year
I/O modules
Current Manual Collection DVD and
For 35 mm modules; 6ES7528-0AA00-7AA0 the three subsequent updates
5 front doors; with 5 labeling strips
(front) and 5 cabling diagrams per
front door; spare part
For 25 mm modules; 6ES7528-0AA00-0AA0
5 front doors; with 5 labeling strips
(front) and 5 cabling diagrams per
front door; spare part
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
General information
Product type designation AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Product function
• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
• Isochronous mode No No Yes No
• Prioritized startup No No No Yes Yes
• Measuring range scalable No No No No
• Scalable measured values No No No Yes
• Adjustment of measuring range No No No Yes
Engineering with
• STEP 7 TIA Portal configurable/inte- V13 / V13.0.2 V15.1 / V16 V12 / V12 V14 / - V14 / -
grated from version
• STEP 7 configurable/integrated from V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -
version
• PROFIBUS from GSD version/GSD V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1
revision
• PROFINET from GSD version/GSD V2.3 / - V2.3 / - V2.3 / - V2.3 / - V2.3 / -
revision
Operating mode
• Oversampling No No No Yes No
• MSI Yes Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
Reverse polarity protection Yes Yes Yes Yes
4
Analog inputs
Number of analog inputs 4 8 8 8 8
• For current measurement 4 8 8 8 8
• For voltage measurement 4 8 8 8 8
• For resistance/resistance 2 8 4
thermometer measurement
• For thermocouple measurement 4 8
permissible input voltage for voltage 28.8 V 12 V; 12 V continuous, 28.8 V 28.8 V 28.8 V
input (destruction limit), max. 30 V for max. 1 s
permissible input current for current 40 mA 40 mA 40 mA 40 mA 40 mA
input (destruction limit), max.
Constant measurement current for 150 Ohm, 300 Ohm, 230 ... 370 µA 150 Ohm, 300 Ohm,
resistance-type transmitter, typ. 600 Ohm, Pt100, 600 Ohm, Pt100,
Pt200, Ni100: 1.25 mA; Pt200, Ni100: 1.25 mA;
6 000 Ohm, Pt500, 6 000 Ohm, Pt500,
Pt1000, Ni1000, Pt1000, Ni1000,
LG-Ni1000: 0.625 mA; LG-Ni1000: 0.625 mA;
PTC: 0.472 mA PTC: 0.472 mA
Technical unit for temperature Yes; °C/°F/K Yes; °C/°F/K Yes; °C/°F/K
measurement adjustable
Analog input with oversampling No
Standardization of measured values No
Input ranges (rated values),
voltages
• 0 to +5 V No No No No No
• 0 to +10 V No No No No No
• 1 V to 5 V Yes Yes Yes Yes Yes
• -1 V to +1 V Yes Yes Yes
• -10 V to +10 V Yes Yes Yes Yes Yes
• -2.5 V to +2.5 V Yes No Yes No Yes
• -25 mV to +25 mV No No No No No
• -250 mV to +250 mV Yes No Yes No No
• -5 V to +5 V Yes Yes Yes Yes Yes
• -50 mV to +50 mV Yes Yes Yes No No
• -500 mV to +500 mV Yes Yes Yes No No
• -80 mV to +80 mV Yes No Yes No No
Input ranges (rated values), currents
• 0 to 10 mA No
• 0 to 20 mA Yes Yes Yes Yes Yes
• -20 mA to +20 mA Yes Yes Yes Yes Yes
• 4 mA to 20 mA Yes Yes Yes Yes Yes
Input ranges (rated values),
thermocouples
• Type B Yes No Yes No No
• Type C No No No No No
• Type E Yes No Yes No No
• Type J Yes No Yes No No
• Type K Yes No Yes No No
• Type L No No No No No
• Type N Yes No Yes No No
• Type R Yes No Yes No No
• Type S Yes No Yes No No
• Type T Yes No Yes No No
• Type U No No
• Type TXK/TXK(L) to GOST No No No No No
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Input ranges (rated values),
resistance thermometer
• Cu 10 No No No No No
• Cu 10 according to GOST No No No No No
4 • Cu 50
• Cu 50 according to GOST
No
No
No
No
No
No
No
No
No
No
• Cu 100 No No No No No
• Cu 100 according to GOST No No No No No
• Ni 10 No No No No No
• Ni 10 according to GOST No No No No No
• Ni 100 Yes; Standard/climate Yes; Standard/climate Yes; Standard/climate No No
• Ni 100 according to GOST No No No No No
• Ni 1000 Yes; Standard/climate Yes; Standard/climate Yes; Standard/climate No No
• Ni 1000 according to GOST No No No No No
• LG-Ni 1000 Yes; Standard/climate Yes; Standard/climate Yes; Standard/climate No No
• Ni 120 No No No No No
• Ni 120 according to GOST No No No No No
• Ni 200 No No No No
• Ni 200 according to GOST No No No No No
• Ni 500 No No No No No
• Ni 500 according to GOST No No No No No
• Pt 10 No No No No No
• Pt 10 according to GOST No No No No No
• Pt 50 No No No No No
• Pt 50 according to GOST No No No No No
• Pt 100 Yes; Standard/climate Yes; Standard/climate Yes; Standard/climate No No
• Pt 100 according to GOST No No No No No
• Pt 1000 Yes; Standard/climate Yes; Standard/climate Yes; Standard/climate No No
• Pt 1000 according to GOST No No No No No
• Pt 200 Yes; Standard/climate No Yes; Standard/climate No No
• Pt 200 according to GOST No No No No No
• Pt 500 Yes; Standard/climate No Yes; Standard/climate No No
• Pt 500 according to GOST No No No No No
Input ranges (rated values),
resistors
• 0 to 150 ohms Yes No Yes No No
• 0 to 300 ohms Yes No Yes No No
• 0 to 600 ohms Yes Yes Yes No No
• 0 to 3000 ohms No No No No No
• 0 to 6000 ohms Yes Yes Yes No No
• PTC Yes Yes Yes No No
Thermocouple (TC)
Temperature compensation
- parameterizable Yes Yes
Cable length
• shielded, max. 800 m; for U/I, 200 m; 800 m; for U/I, 800 m 800 m
200 m for R/RTD, 50 m at 50 mV 200 m for R/RTD,
50 m for TC 50 m for TC
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Analog value generation
for the inputs
Integration and conversion
time/resolution per channel
• Resolution with overrange
(bit including sign), max.
16 bit 16 bit 16 bit 16 bit 24 bit; When using the
function "Scaling of the
measured values" or
4
"Measuring range
adaptation"
(32 bit REAL format);
16 bit when using
the S7 format
(16 bit INTEGER)
• Integration time, parameterizable Yes Yes Yes Yes
• Integration time (ms) 2,5 / 16,67 / 20 / 2,5 / 16,67 / 20 / 2,5 / 16,67 / 20 / Fast mode: 2.5 /
100 ms 100 ms 100 ms 16.67 / 20 / 100 ms,
standard mode: 7.5 /
50 / 60 / 300 ms
• Basic conversion time, including 9 / 23 / 27 / 107 ms 10 / 24 / 27 / 107 ms 9 / 23 / 27 / 107 ms Fast mode: 4 / 18 / 22 /
integration time (ms) 102 ms; Standard
mode: 9 / 52 / 62 /
302 ms
- additional conversion time for 9 ms (to be considered 4 ms (to be considered 9 ms (to be considered
wire-break monitoring in R/RTD/TC in R/RTD/U 1 to 5 V in R/RTD/TC
measurement) measurement) measurement)
- additional conversion time for 150 ohm, 300 ohm, 8 ms 150 ohm, 300 ohm,
resistance measurement 600 ohm, Pt100, 600 ohm, Pt100,
Pt200, Ni100: 2 ms, Pt200, Ni100: 2 ms,
6000 ohm, Pt500, 6000 ohm, Pt500,
Pt1000, Ni1000, Pt1000, Ni1000,
LG-Ni1000, PTC: 4 ms LG-Ni1000, PTC: 4 ms
• Interference voltage suppression for 400 / 60 / 50 / 10 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz
interference frequency f1 in Hz
• Basic execution time of the module Corresponds to the
(all channels released) channel with the
highest basic
conversion time
• Basic execution time of the module 62.5 µs; independent
(all channels released) of number of activated
channels
Smoothing of measured values
• parameterizable Yes Yes Yes Yes Yes
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes Yes Yes Yes
• for current measurement as 2-wire Yes Yes; with external Yes Yes Yes; with external
transducer supply transmitter supply
- Burden of 2-wire transmitter, max. 820 Ω 820 Ω 820 Ω
• for current measurement as 4-wire Yes Yes Yes Yes Yes
transducer
• for resistance measurement with Yes; Only for PTC Yes; Only for PTC Yes; Only for PTC No No
two-wire connection
• for resistance measurement with Yes; All measuring Yes; All measuring Yes; All measuring No No
three-wire connection ranges except PTC; ranges except PTC; ranges except PTC;
internal compensation internal compensation internal compensation
of the cable of the cable of the cable
resistances resistances resistances
• for resistance measurement with Yes; All measuring Yes; All measuring No No
four-wire connection ranges except PTC ranges except PTC
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Errors/accuracies
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input 0.1 % 0.3 % 0.1 % 0.2 % 0.05 %
4 range, (+/-)
• Current, relative to input 0.1 % 0.3 % 0.1 % 0.2 % 0.05 %
range, (+/-)
• Resistance, relative to input 0.1 % 0.3 % 0.1 %
range, (+/-)
• Resistance thermometer, 0.1 %; Ptxxx Standard: ±1.0 K, Ptxxx standard: ±0.7 K,
relative to input range, (+/-) Ptxxx standard: ±0.7 K, Ptxxx Climate: ±0.5 K, Ptxxx climate: ±0.2 K,
Ptxxx climate: ±0.2 K, Nixxx Standard: ±0.5 K, Nixxx standard: ±0.3 K,
Nixxx standard: ±0.3 K, Nixxx Climate: ±0.5 K Nixxx climate: ±0.15 K
Nixxx climate: ±0.15 K
• Thermocouple, relative to input 0.1 %; Type B: > 600 °C
range, (+/-) Type B: > 600 °C ±1.7 K,
±1.7 K, type E: > -200 °C
type E: > -200 °C ±0.7 K,
±0.7 K, type J: > -210 °C
type J: > -210 °C ±0.8 K,
±0.8 K, type K: > -200 °C
type K: > -200 °C ±1.2 K,
±1.2 K, type N: > -200 °C
type N: > -200 °C ±1.2 K,
±1.2 K, type R: > 0 °C ±1.9 K,
type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K,
type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K
type T: > -200 °C
±0.8 K
Interference voltage suppression for
f = n x (f1 +/- 1 %),
f1 = interference frequency
• Series mode interference 40 dB 40 dB 40 dB 80 dB;
(peak value of interference < rated in the Standard
value of input range), min. operating mode,
40 dB in the Fast
operating mode
• Common mode voltage, max. 10 V 4V 10 V 10 V 60 V DC/30 V AC
• Common mode interference, min. 60 dB 60 dB 60 dB 50 dB at 400 Hz; 60 80 dB
dB at 60 / 50 / 10 Hz
Isochronous mode
Filtering and processing time (TCI), min. 80 µs
Bus cycle time (TDP), min. 250 µs
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes Yes Yes Yes
• Limit value alarm Yes; two upper and Yes; two upper and Yes; two upper and Yes; two upper and Yes; two upper and
two lower limit values two lower limit values two lower limit values two lower limit values two lower limit values
in each case in each case in each case in each case in each case
Diagnoses
• Monitoring the supply voltage Yes No Yes Yes Yes
• Wire-break Yes; Only for 1 to 5 V, 4 Yes; Only for 1 ... 5 V, 4 Yes; Only for 1 to 5 V, 4 Yes; only for 1 ... 5 V Yes; only for 1 ... 5 V
to 20 mA, TC, R, and ... 20 mA, R, and RTD to 20 mA, TC, R, and and 4 ... 20 mA and 4 ... 20 mA
RTD RTD
• Short-circuit No
• Group error No
• Overflow/underflow Yes Yes Yes Yes Yes
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• MAINT LED No
• Monitoring of the supply voltage Yes; green LED No Yes; green LED Yes; green LED Yes; green LED
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• for channel diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• for module diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
■ Technical specifications
Article number 6ES7531-7QD00- 6ES7531-7QF00- 6ES7531-7KF00- 6ES7531-7NF10- 6ES7531-7NF00-
0AB0 0AB0 0AB0 0AB0 0AB0
S7-1500, S7-1500, S7-1500, S7-1500, S7-1500,
AI 4xU/I/RTD/TC ST AI 8xU/I/R/RTD BA AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
Potential separation
Potential separation channels
• between the channels Yes Yes Yes Yes Yes
and backplane bus
Standards, approvals, certificates
Suitable for applications according Yes; Declaration of
4
to AMS 2750 Conformity, see online
support entry
109757262
Suitable for applications according Yes; Based on AMS
to CQI-9 2750 E
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. 0 °C 0 °C 0 °C -25 °C; From FS02 -30 °C; From FS02
• horizontal installation, max. 60 °C 60 °C 60 °C 60 °C 60 °C
• vertical installation, min. 0 °C 0 °C 0 °C -25 °C; From FS02 -30 °C; From FS02
• vertical installation, max. 40 °C 40 °C 40 °C 40 °C 40 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions 5 000 m; Restrictions
max. for installation altitudes for installation altitudes for installation altitudes for installation altitudes
> 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual > 2 000 m, see manual
Dimensions
Width 25 mm 35 mm 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 210 g 250 g 310 g 300 g 280 g
Other
Note: Supplied incl. Additional basic error
40-pole push-in front and noise for integration
connectors. Additional time = 2.5 ms:
basic error and noise Voltage:
for integration ±250 mV (±0.02%),
time = 2.5 ms: ±80 mV (±0.05%),
Voltage: ±50 mV (±0.05%);
±250 mV (±0.02%), resistance:
±80 mV (±0.05%), 150 ohms ±0.02%;
±50 mV (±0.05%); resistance
resistance: thermometer:
150 Ohms (±0.02%); Pt100 climate: ±0.08 K,
resistance Ni100 climate: ±0.08 K;
thermometer: thermocouple:
Pt100 climate: ±0.08 K, Type B, R, S: ±3 K,
Ni100 climate: ±0.08 K; type E, J, K, N, T: ±1 K
thermoelement:
Type B, R, S: ±3 K,
type E, J, K, N, T: ±1 K
■ Technical specifications
Article number 6ES7531-7LH00-0AB0 6ES7531-7MH00-0AB0
S7-1500, AI 16xU BA S7-1500, AI 16xI BA
General information
Product type designation AI 16xU BA AI 16xI BA
Product function
• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
• Isochronous mode No No
4 • Prioritized startup
• Measuring range scalable
No
No
No
No
• Scalable measured values No No
• Adjustment of measuring range No No
Engineering with
• STEP 7 TIA Portal configurable/ V16 with HSP 312 / V17 V16 with HSP 312 / V17
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.3 / -
GSD revision
Operating mode
• Oversampling No No
• MSI Yes Yes
Analog inputs
Number of analog inputs 16 16
• For current measurement 16
• For voltage measurement 16
permissible input voltage for voltage 12 V; 12 V continuous, 30 V for max. 1 s
input (destruction limit), max.
permissible input current for current 40 mA
input (destruction limit), max.
Input ranges (rated values),
voltages
• 0 to +5 V No
• 0 to +10 V No
• 1 V to 5 V Yes
• -1 V to +1 V Yes
• -10 V to +10 V Yes
• -2.5 V to +2.5 V No
• -25 mV to +25 mV No
• -250 mV to +250 mV No
• -5 V to +5 V Yes
• -50 mV to +50 mV No
• -500 mV to +500 mV No
• -80 mV to +80 mV No
Input ranges (rated values), currents
• 0 to 10 mA No
• 0 to 20 mA Yes
• -20 mA to +20 mA Yes
• 4 mA to 20 mA Yes
Cable length
• shielded, max. 200 m 800 m
■ Technical specifications
Article number 6ES7531-7LH00-0AB0 6ES7531-7MH00-0AB0
S7-1500, AI 16xU BA S7-1500, AI 16xI BA
Analog value generation for
the inputs
Integration and conversion
time/resolution per channel
• Resolution with overrange 16 bit 16 bit
(bit including sign), max.
• Integration time, parameterizable
• Basic conversion time, including
Yes
10 / 24 / 27 / 107 ms
Yes
10 / 24 / 27 / 107 ms
4
integration time (ms)
- additional conversion time for 4 ms (to be considered for 1 to 5 V measurement)
wire-break monitoring
• Interference voltage suppression 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz
for interference frequency f1 in Hz
Smoothing of measured values
• parameterizable Yes Yes
Encoder
Connection of signal encoders
• for voltage measurement Yes No
• for current measurement as Yes; with external supply
2-wire transducer
• for current measurement as Yes
4-wire transducer
• for resistance measurement with No
two-wire connection
• for resistance measurement with No
three-wire connection
• for resistance measurement with No
four-wire connection
Errors/accuracies
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input range, (+/-) 0.3 %
• Current, relative to input range, (+/-) 0.3 %
Interference voltage suppression for
f = n x (f1 +/- 1 %),
f1 = interference frequency
• Series mode interference 40 dB 40 dB
(peak value of interference < rated
value of input range), min.
• Common mode voltage, max. 4V 4V
• Common mode interference, min. 60 dB 60 dB
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes
Alarms
• Diagnostic alarm Yes Yes
• Limit value alarm Yes; two upper and two lower limit values in each case Yes; two upper and two lower limit values in each case
Diagnoses
• Monitoring the supply voltage No No
• Wire-break Yes; Only for 1 ... 5 V Yes; Only for 4 ... 20 mA
• Short-circuit No No
• Group error No No
• Overflow/underflow Yes Yes
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED
• MAINT LED No No
• Monitoring of the supply voltage No No
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED
• for channel diagnostics Yes; red LED Yes; red LED
• for module diagnostics Yes; red LED Yes; red LED
■ Technical specifications
Article number 6ES7531-7LH00-0AB0 6ES7531-7MH00-0AB0
S7-1500, AI 16xU BA S7-1500, AI 16xI BA
Potential separation
Potential separation channels
• between the channels and Yes Yes
backplane bus
Ambient conditions
4 Ambient temperature
during operation
• horizontal installation, min. -30 °C -30 °C
• horizontal installation, max. 60 °C 60 °C
• vertical installation, min. -30 °C -30 °C
• vertical installation, max. 40 °C 40 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m; Restrictions for installation altitudes > 2 000 m, 5 000 m; Restrictions for installation altitudes > 2 000 m,
max. see manual see manual
Dimensions
Width 35 mm 35 mm
Height 147 mm 147 mm
Depth 129 mm 129 mm
Weights
Weight, approx. 250 g 250 g
■ Technical specifications
Article number 6ES7531-7PF00-0AB0 Article number 6ES7531-7PF00-0AB0
S7-1500, AI 8 X U/R/RTD/TC HF S7-1500, AI 8 X U/R/RTD/TC HF
Input ranges (rated values), Analog value generation
resistance thermometer for the inputs
• Cu 10 Yes; Standard/climate Integration and conversion
• Cu 10 according to GOST Yes; Standard/climate time/resolution per channel
• Cu 50 Yes; Standard/climate • Resolution with overrange 21 bit; For measuring mode RTC and
(bit including sign), max. TC when using the function "Scalable
• Cu 50 according to GOST
• Cu 100
Yes; Standard/climate
Yes; Standard/climate
temperature measuring range"
(32 bit REAL format);
16 bit for measuring mode R and U;
4
• Cu 100 according to GOST Yes; Standard/climate 16 bit for all measuring modes when
• Ni 10 Yes; Standard/climate using the S7 format (16 bit INTEGER)
• Ni 10 according to GOST Yes; Standard/climate • Integration time, parameterizable Yes
• Ni 100 Yes; Standard/climate • Integration time (ms) Fast mode: 2.5 / 16.67 / 20 / 100 ms,
standard mode: 7.5 / 50 / 60 / 300 ms
• Ni 100 according to GOST Yes; Standard/climate
• Basic conversion time, including Fast mode: 4 / 18 / 22 / 102 ms;
• Ni 1000 Yes; Standard/climate
integration time (ms) Standard mode: 9 / 52 / 62 / 302 ms
• Ni 1000 according to GOST Yes; Standard/climate
- additional conversion time Thermocouples, 150 Ohm, 300 Ohm,
• LG-Ni 1000 Yes; Standard/climate for wire-break monitoring 600 Ohm, Cu10, Cu50, Cu100, Ni10,
• Ni 120 Yes; Standard/climate Ni100, Ni120, Ni200, Pt10, Pt50,
Pt100: 4 ms; 6 kOhm, Ni500, Ni1000,
• Ni 120 according to GOST Yes; Standard/climate LG-Ni1000, Pt200, Pt500, Pt1000:
• Ni 200 Yes; Standard/climate 13 ms
• Ni 200 according to GOST Yes; Standard/climate • Interference voltage suppression for 400 / 60 / 50 / 10 Hz
interference frequency f1 in Hz
• Ni 500 Yes; Standard/climate
• Basic execution time of the module Corresponds to the channel with the
• Ni 500 according to GOST Yes; Standard/climate (all channels released) highest basic conversion time
• Pt 10 Yes; Standard/climate Smoothing of measured values
• Pt 10 according to GOST Yes; Standard/climate • parameterizable Yes
• Pt 50 Yes; Standard/climate Encoder
• Pt 50 according to GOST Yes; Standard/climate Connection of signal encoders
• Pt 100 Yes; Standard/climate • for voltage measurement Yes
• Pt 100 according to GOST Yes; Standard/climate • for current measurement as No
• Pt 1000 Yes; Standard/climate 2-wire transducer
• Pt 1000 according to GOST Yes; Standard/climate • for current measurement as No
• Pt 200 Yes; Standard/climate 4-wire transducer
• Pt 200 according to GOST Yes; Standard/climate • for resistance measurement with Yes
two-wire connection
• Pt 500 Yes; Standard/climate
• for resistance measurement with Yes; All measuring ranges except
• Pt 500 according to GOST Yes; Standard/climate three-wire connection PTC; internal compensation of the
Input ranges (rated values), cable resistances
resistors • for resistance measurement with Yes; All measuring ranges
• 0 to 150 ohms Yes four-wire connection except PTC
• 0 to 300 ohms Yes Errors/accuracies
• 0 to 600 ohms Yes Basic error limit (operational limit at
25 °C)
• 0 to 3000 ohms No
• Voltage, relative to input range, (+/-) 0.05 %
• 0 to 6000 ohms Yes
• Resistance, relative to input range, 0.05 %
• PTC Yes (+/-)
Thermocouple (TC) • Resistance thermometer, relative to Cuxxx Standard: ±0.3 K,
Temperature compensation input range, (+/-) Cuxxx Klima: ±0.2 K,
- parameterizable Yes Ptxxx Standard: ±0.5 K,
Ptxxx Klima: ±0.2 K,
Cable length Nixxx Standard: ±0.3 K,
• shielded, max. 800 m; at U; 200 m at R/RTD/TC Nixxx Klima: ±0.15 K
• Thermocouple, relative to input Type B: > 600 °C ±1 K, Type E:
range, (+/-) > -200 °C ±0.5 K, Type J: > -210 °C
±0.5 K, Type K: > -200 °C ±1 K,
Type N: > -200 °C ±1 K, Type R: > 0 °C
±1 K, Type S: > 0 °C ±1 K, Type T:
> -200 °C ±0.5 K, Type C: ±2 K,
Type TXK/TXK(L): ±0.5 K
Interference voltage suppression for
f = n x (f1 +/- 1 %),
f1 = interference frequency
• Series mode interference (peak 80 dB; in the Standard operating
value of interference < rated value of mode, 40 dB in the Fast operating
input range), min. mode
• Common mode voltage, max. 60 V DC/30 V AC
• Common mode interference, min. 80 dB
■ Technical specifications
Article number 6ES7531-7PF00-0AB0 Article number 6ES7531-7PF00-0AB0
S7-1500, AI 8 X U/R/RTD/TC HF S7-1500, AI 8 X U/R/RTD/TC HF
Interrupts/diagnostics/ Standards, approvals, certificates
status information Suitable for applications according to Yes; Declaration of Conformity, see
Diagnostics function Yes AMS 2750 online support entry 109757262
Alarms Suitable for applications according to Yes; Based on AMS 2750 E
• Diagnostic alarm Yes CQI-9
4 • Limit value alarm Yes; two upper and two lower limit Ambient conditions
values in each case Ambient temperature during
Diagnoses operation
• Monitoring the supply voltage Yes • horizontal installation, min. 0 °C
• Wire-break Yes; Only with TC, R, RTD • horizontal installation, max. 60 °C
• Overflow/underflow Yes • vertical installation, min. 0 °C
Diagnostics indication LED • vertical installation, max. 40 °C
• RUN LED Yes; green LED Dimensions
• ERROR LED Yes; red LED Width 35 mm
• Monitoring of the supply voltage Yes; green LED Height 147 mm
(PWR-LED) Depth 129 mm
• Channel status display Yes; green LED Weights
• for channel diagnostics Yes; red LED Weight, approx. 290 g
• for module diagnostics Yes; red LED Other
Potential separation Note: for the R/RDT three-wire
Potential separation channels measurement, the conductor
compensation is made alternating
• between the channels and Yes with the measurement; this then
backplane bus requires two module cycles for
a measured value
■ Overview
• 2, 4 and 8-channel analog output modules
• Optionally with extremely short conversion times
• For connecting analog actuators without additional amplifiers
• Even solves more complex automation tasks
■ Technical specifications
Article number 6ES7532-5NB00-0AB0 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0 6ES7532-5ND00-0AB0
S7-1500, AQ 2xU/I ST S7-1500, AQ 4xU/I ST S7-1500, AQ 8xU/I HS S7-1500, AQ 4xU/I HF
General information
Product type designation AQ 2xU/I ST AQ 4xU/I ST AQ 8xU/I HS AQ 4xU/I HF
Product function
• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
• Isochronous mode No No Yes Yes
4 • Prioritized startup
• Output range scalable
No
No
No
No
No
No
Yes
Engineering with
• STEP 7 TIA Portal configurable/ V13 / V13.0.2 V12 / V12 V14 / - V14 / -
integrated from version
• STEP 7 configurable/ V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -
integrated from version
• PROFIBUS from GSD version/ V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1
GSD revision
• PROFINET from GSD version/ V2.3 / - V2.3 / - V2.3 / - V2.3 / -
GSD revision
Operating mode
• Oversampling No No Yes No
• MSO Yes Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
Reverse polarity protection Yes Yes Yes Yes
Analog outputs
Number of analog outputs 2 4 8 4
Cycle time (all channels), min. 3.2 ms; independent of 3.2 ms; independent of 125 µs; independent of 125 µs; independent of
number of activated channels number of activated channels number of activated channels number of activated channels
Output ranges, voltage
• 0 to 10 V Yes Yes Yes Yes
• 1 V to 5 V Yes Yes Yes Yes
• -5 V to +5 V No No No No
• -10 V to +10 V Yes Yes Yes Yes
Output ranges, current
• 0 to 20 mA Yes Yes Yes Yes
• -20 mA to +20 mA Yes Yes Yes Yes
• 4 mA to 20 mA Yes Yes Yes Yes
Connection of actuators
• for voltage output two-wire Yes Yes Yes Yes
connection
• for voltage output four-wire Yes Yes Yes Yes
connection
• for current output two-wire Yes Yes Yes Yes
connection
Load impedance (in rated range of
output)
• with voltage outputs, min. 1 kΩ; 0.5 kOhm at 1 to 5 V 1 kΩ; 0.5 kOhm at 1 to 5 V 1 kΩ 1 kΩ; 0.5 kOhm at 1 to 5 V
• with voltage outputs, capacitive 1 µF 1 µF 100 nF 1 µF
load, max.
• with current outputs, max. 750 Ω 750 Ω 500 Ω 750 Ω
• with current outputs, inductive load, 10 mH 10 mH 1 mH 10 mH
max.
Cable length
• shielded, max. 800 m; for current, 800 m; for current, 200 m 800 m; for current,
200 m for voltage 200 m for voltage 200 m for voltage
■ Technical specifications
Article number 6ES7532-5NB00-0AB0 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0 6ES7532-5ND00-0AB0
S7-1500, AQ 2xU/I ST S7-1500, AQ 4xU/I ST S7-1500, AQ 8xU/I HS S7-1500, AQ 4xU/I HF
Analog value generation
for the outputs
Integration and conversion
time/resolution per channel
• Resolution with overrange 16 bit 16 bit 16 bit 16 bit
(bit including sign), max.
• Conversion time (per channel) 0.5 ms 0.5 ms 50 µs; independent of number 125 µs; independent of
of activated channels number of activated channels 4
Settling time
• for resistive load 1.5 ms 1.5 ms 30 µs; see additional 0.2 ms; see additional
description in the manual description in the manual
• for capacitive load 2.5 ms 2.5 ms 100 µs; see additional 1.8 ms; see additional
description in the manual description in the manual
• for inductive load 2.5 ms 2.5 ms 100 µs; see additional 2 ms; see additional
description in the manual description in the manual
Errors/accuracies
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to output range, (+/-) 0.2 % 0.2 % 0.2 % 0.06 %
• Current, relative to output range, (+/-) 0.2 % 0.2 % 0.2 % 0.1 %
Isochronous mode
Execution and activation time (TCO), 100 µs 100 µs
min.
Bus cycle time (TDP), min. 250 µs 250 µs
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes Yes Yes
Substitute values connectable Yes Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes Yes Yes
Diagnoses
• Monitoring the supply voltage Yes Yes Yes Yes
• Wire-break Yes; Only for output type Yes; Only for output type Yes; Only for output type Yes; Only for output type
"current" "current" "current" "current"
• Short-circuit Yes; Only for output type Yes; Only for output type Yes; Only for output type Yes; Only for output type
"voltage" "voltage" "voltage" "voltage"
• Overflow/underflow Yes Yes Yes Yes
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• Monitoring of the supply voltage Yes; green LED Yes; green LED Yes; green LED Yes; green LED
(PWR-LED)
• Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• for channel diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• for module diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
Potential separation
Potential separation channels
• between the channels Yes Yes Yes Yes
and backplane bus
■ Technical specifications
Article number 6ES7532-5NB00-0AB0 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0 6ES7532-5ND00-0AB0
S7-1500, AQ 2xU/I ST S7-1500, AQ 4xU/I ST S7-1500, AQ 8xU/I HS S7-1500, AQ 4xU/I HF
Standards, approvals, certificates
Suitable for safety-related tripping Yes; From FS02 Yes; From FS05 Yes; from FS04 Yes; From FS03
of standard modules
Highest safety class achievable
for safety-related tripping of
standard modules
■ Overview
• 4 analog inputs/ 2 analog outputs
• For flexible adaptation of the controller to the corresponding task
• For subsequent expansion of the system with additional inputs
and outputs
• For use in the tightest spaces
■ Technical specifications
Article number 6ES7534-7QE00-0AB0 Article number 6ES7534-7QE00-0AB0
S7-1500, S7-1500,
AI 4x U/I/RTD/TC/AQ 2x U/I ST AI 4x U/I/RTD/TC/AQ 2x U/I ST
General information Input ranges (rated values), currents
Product type designation AI 4xU/I/RTD/TC /AQ 2xU/I ST • 0 to 20 mA Yes
Product function • -20 mA to +20 mA Yes
• I&M data Yes; I&M0 to I&M3 • 4 mA to 20 mA Yes
4 • Isochronous mode
• Prioritized startup
No
No
Input ranges (rated values),
thermocouples
• Measuring range scalable No • Type B Yes
• Scalable measured values No • Type C No
• Adjustment of measuring range No • Type E Yes
• Output range scalable No • Type J Yes
Engineering with • Type K Yes
• STEP 7 TIA Portal configurable/ V13 / V13.0.2 • Type L No
integrated from version • Type N Yes
• STEP 7 configurable/ V5.5 SP3 / - • Type R Yes
integrated from version • Type S Yes
• PROFIBUS from GSD version/ V1.0 / V5.1 • Type T Yes
GSD revision
• Type U No
• PROFINET from GSD version/ V2.3 / -
GSD revision • Type TXK/TXK(L) to GOST No
Operating mode Input ranges (rated values),
resistance thermometer
• Oversampling No
• Cu 10 No
• MSI Yes
• Cu 10 according to GOST No
• MSO Yes
• Cu 50 No
Supply voltage
• Cu 50 according to GOST No
Rated value (DC) 24 V
• Cu 100 No
Reverse polarity protection Yes
• Cu 100 according to GOST No
Analog inputs
• Ni 10 No
Number of analog inputs 4
• Ni 10 according to GOST No
• For current measurement 4
• Ni 100 Yes; Standard/climate
• For voltage measurement 4
• Ni 100 according to GOST No
• For resistance/resistance 2
thermometer measurement • Ni 1000 Yes; Standard/climate
• For thermocouple measurement 4 • Ni 1000 according to GOST No
permissible input voltage for voltage 28.8 V • LG-Ni 1000 Yes; Standard/climate
input (destruction limit), max. • Ni 120 No
permissible input current for current 40 mA • Ni 120 according to GOST No
input (destruction limit), max.
• Ni 200 No
Constant measurement current for 150 Ohm, 300 Ohm, 600 Ohm,
resistance-type transmitter, typ. Pt100, Pt200, Ni100: 1.25 mA; • Ni 200 according to GOST No
6 000 Ohm, Pt500, Pt1000, Ni1000, • Ni 500 No
LG-Ni1000: 0.625 mA;
• Ni 500 according to GOST No
PTC: 0.472 mA
• Pt 10 No
Technical unit for temperature Yes; °C/°F/K
measurement adjustable • Pt 10 according to GOST No
Analog input with oversampling No • Pt 50 No
Standardization of measured values No • Pt 50 according to GOST No
Input ranges (rated values), • Pt 100 Yes; Standard/climate
voltages • Pt 100 according to GOST No
• 0 to +5 V No • Pt 1000 Yes; Standard/climate
• 0 to +10 V No • Pt 1000 according to GOST No
• 1 V to 5 V Yes • Pt 200 Yes; Standard/climate
• -1 V to +1 V Yes • Pt 200 according to GOST No
• -10 V to +10 V Yes • Pt 500 Yes; Standard/climate
• -2.5 V to +2.5 V Yes • Pt 500 according to GOST No
• -25 mV to +25 mV No
• -250 mV to +250 mV Yes
• -5 V to +5 V Yes
• -50 mV to +50 mV Yes
• -500 mV to +500 mV Yes
• -80 mV to +80 mV Yes
■ Technical specifications
Article number 6ES7534-7QE00-0AB0 Article number 6ES7534-7QE00-0AB0
S7-1500, S7-1500,
AI 4x U/I/RTD/TC/AQ 2x U/I ST AI 4x U/I/RTD/TC/AQ 2x U/I ST
Input ranges (rated values), Analog value generation
resistors for the inputs
• 0 to 150 ohms Yes Integration and conversion
• 0 to 300 ohms Yes time/resolution per channel
• 0 to 600 ohms Yes • Resolution with overrange 16 bit
• 0 to 3000 ohms No
(bit including sign), max.
• Integration time, parameterizable Yes 4
• 0 to 6000 ohms Yes
• Basic conversion time, including 9 / 23 / 27 / 107 ms
• PTC Yes integration time (ms)
Thermocouple (TC) - additional conversion time 9 ms
Temperature compensation for wire-break monitoring
- parameterizable Yes - additional conversion time 150 ohm, 300 ohm, 600 ohm,
for resistance measurement Pt100, Pt200, Ni100: 2 ms,
Cable length 6000 ohm, Pt500, Pt1000, Ni1000,
• shielded, max. 800 m; for U/I, 200 m for R/RTD, LG-Ni1000, PTC: 4 ms
50 m for TC • Interference voltage suppression for 400 / 60 / 50 / 10
Analog outputs interference frequency f1 in Hz
Number of analog outputs 2 Smoothing of measured values
Cycle time (all channels), min. 3.2 ms; ±0.5 ms, regardless of • parameterizable Yes
the number of activated channels Analog value generation for
Output ranges, voltage the outputs
• 0 to 10 V Yes Integration and conversion
time/resolution per channel
• 1 V to 5 V Yes
• Resolution with overrange 16 bit
• -5 V to +5 V No
(bit including sign), max.
• -10 V to +10 V Yes
• Conversion time (per channel) 0.5 ms
Output ranges, current
Settling time
• 0 to 20 mA Yes
• for resistive load 1.5 ms
• -20 mA to +20 mA Yes
• for capacitive load 2.5 ms
• 4 mA to 20 mA Yes
• for inductive load 2.5 ms
Connection of actuators
Encoder
• for voltage output two-wire Yes
Connection of signal encoders
connection
• for voltage measurement Yes
• for voltage output four-wire Yes
connection • for current measurement as Yes
2-wire transducer
• for current output two-wire Yes
connection - Burden of 2-wire transmitter, max. 820 Ω
Load impedance • for current measurement as Yes
(in rated range of output) 4-wire transducer
• with voltage outputs, min. 1 kΩ; 0.5 kOhm at 1 to 5 V • for resistance measurement with Yes; Only for PTC
two-wire connection
• with voltage outputs, capacitive 1 µF
load, max. • for resistance measurement with Yes; All measuring ranges except PTC;
three-wire connection internal compensation of the cable
• with current outputs, max. 750 Ω
resistances
• with current outputs, inductive load, 10 mH
• for resistance measurement with Yes; All measuring ranges except PTC
max.
four-wire connection
Cable length
• shielded, max. 800 m; for current, 200 m for voltage
■ Technical specifications
Article number 6ES7534-7QE00-0AB0 Article number 6ES7534-7QE00-0AB0
S7-1500, S7-1500,
AI 4x U/I/RTD/TC/AQ 2x U/I ST AI 4x U/I/RTD/TC/AQ 2x U/I ST
Errors/accuracies Potential separation
Basic error limit Potential separation analog inputs
(operational limit at 25 °C) • between the channels and Yes
• Voltage, relative to input range, (+/-) 0.1 % backplane bus
• Current, relative to input range, (+/-) 0.1 %
4
Potential separation analog outputs
• Resistance, relative to input range, 0.1 % • between the channels and Yes
(+/-) backplane bus
• Resistance thermometer, 0.1 %; Ptxxx standard: ±0.7 K, Ambient conditions
relative to input range, (+/-) Ptxxx climate: ±0.2 K, Ambient temperature during
Nixxx standard: ±0.3 K, operation
Nixxx climate: ±0.15 K
• horizontal installation, min. 0 °C
• Thermocouple, 0.1 %; Type B: > 600 °C ±1.7 K,
relative to input range, (+/-) type E: > -200 °C ±0.7 K, • horizontal installation, max. 60 °C
type J: > -210 °C ±0.8 K, • vertical installation, min. 0 °C
type K: > -200 °C ±1.2 K,
type N: > -200 °C ±1.2 K, • vertical installation, max. 40 °C
type R: > 0 °C ±1.9 K, Altitude during operation
type S: > 0 °C ±1.9 K, relating to sea level
type T: > -200 °C ±0.8 K
• Installation altitude above sea level, 5 000 m; Restrictions for installation
• Voltage, relative to output range, 0.2 % max. altitudes > 2 000 m, see manual
(+/-)
Dimensions
• Current, relative to output range, 0.2 %
Width 25 mm
(+/-)
Height 147 mm
Interference voltage suppression for
f = n x (f1 +/- 1 %), Depth 129 mm
f1 = interference frequency Weights
• Series mode interference 40 dB Weight, approx. 250 g
(peak value of interference < rated
value of input range), min. Other
• Common mode voltage, max. 10 V Note: Supplied incl. 40-pole push-in
front connectors. Additional basic
• Common mode interference, min. 60 dB error and noise for
Interrupts/diagnostics/ integration time = 2.5 ms:
status information Voltage:
±250 mV (±0.02%),
Diagnostics function Yes
±80 mV (±0.05%),
Substitute values connectable Yes ±50 mV (±0.05%); r
Alarms esistance:
150 Ohms (±0.02%);
• Diagnostic alarm Yes resistance thermometer:
• Limit value alarm Yes; two upper and two lower limit Pt100 climate: ±0.08 K,
values in each case Ni100 climate: ±0.08 K;
thermoelement:
Diagnoses type B, R, S: ±3 K,
• Monitoring the supply voltage Yes type E, J, K, N, T: ±1 K
• Wire-break Yes; only for input type 1 ... 5 V,
4 ... 20 mA, TC, R, RTD and
output type current
• Short-circuit Yes; Only for output type "voltage"
• Overflow/underflow Yes
Diagnostics indication LED
• RUN LED Yes; green LED
• ERROR LED Yes; red LED
• Monitoring of the supply voltage Yes; green LED
(PWR-LED)
• Channel status display Yes; green LED
• for channel diagnostics Yes; red LED
• for module diagnostics Yes; red LED
■ Technical specifications
Article number 6AG1531-7NF10-7AB0 6AG1531-7KF00-7AB0 6AG1531-7NF00-7AB0 6AG1531-7PF00-4AB0
Based on 6ES7531-7NF10-0AB0 6ES7531-7KF00-0AB0 6ES7531-7NF00-0AB0 6ES7531-7PF00-0AB0
SIPLUS S7-1500 AI 8xU/I HS SIPLUS S7-1500 AI SIPLUS S7-1500 AI 8XU/I HF SIPLUS S7-1500 AI
8xU/I/RTD/TC ST 8XU/R/RTD/TC HF
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin 0 °C; = Tmin
(incl. condensation/frost) (incl. condensation/frost) (incl. condensation/frost) (incl. condensation/frost)
• horizontal installation, max. 70 °C; = Tmax 70 °C; = Tmax 70 °C; = Tmax 60 °C; = Tmax
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin 0 °C; = Tmin
• vertical installation, max. 40 °C; = Tmax 40 °C; = Tmax 40 °C; = Tmax 40 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
■ Technical specifications
Article number 6AG1531-7NF10-7AB0 6AG1531-7KF00-7AB0 6AG1531-7NF00-7AB0 6AG1531-7PF00-4AB0
Based on 6ES7531-7NF10-0AB0 6ES7531-7KF00-0AB0 6ES7531-7NF00-0AB0 6ES7531-7PF00-0AB0
SIPLUS S7-1500 AI 8xU/I HS SIPLUS S7-1500 AI SIPLUS S7-1500 AI 8XU/I HF SIPLUS S7-1500 AI
8xU/I/RTD/TC ST 8XU/R/RTD/TC HF
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation / frost condensation / frost
max. (no commissioning under (no commissioning under (no commissioning (no commissioning
■ Technical specifications
Article number 6AG1532-5HD00-7AB0 6AG1532-5HF00-7AB0
Based on 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0
SIPLUS S7-1500 AQ 4xU/I ST SIPLUS S7-1500 AQ 8xU/I HS
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
• horizontal installation, max. 70 °C; = Tmax 70 °C; = Tmax; > +60 °C max. 4x ±10 V permissible
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin; Startup @ -25 °C
• vertical installation, max. 40 °C; = Tmax 40 °C; = Tmax
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in accor- 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
dance with IEC 60068-2-38, max. under condensation conditions) under condensation conditions)
■ Technical specifications
Article number 6AG1532-5HD00-7AB0 6AG1532-5HF00-7AB0
Based on 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0
SIPLUS S7-1500 AQ 4xU/I ST SIPLUS S7-1500 AQ 8xU/I HS
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
■ Overview
• 2-channel high-speed counter module
• With comprehensive parameterization options for an optimum
adaptation to the task and reduction of control load
• Speed and time period measuring
• Storage and comparison functions
• Connection of 24 V encoders
■ Technical specifications
Article number 6ES7550-1AA01-0AB0 Article number 6ES7550-1AA01-0AB0
S7-1500, TM Count 2x24V S7-1500, TM Count 2x24V
General information Installation type/mounting
Product type designation TM Count 2x24V Rail mounting Yes; S7-1500 mounting rail
Product function Supply voltage
• I&M data Yes; I&M0 to I&M3 Load voltage L+
• Isochronous mode Yes • Rated value (DC) 24 V
Engineering with • Reverse polarity protection Yes
• STEP 7 TIA Portal configurable/ V16 with HSP 0332 / V17 Encoder supply
integrated from version Number of outputs 1; A common 24V encoder supply for
• PROFIBUS from GSD version/ GSD Revision 5 both channels
GSD revision 24 V encoder supply
• PROFINET from GSD version/ V2.3 / - • 24 V Yes; L+ (-0.8 V)
GSD revision
• Short-circuit protection Yes
• Output current, max. 1 A; total current of all
encoders/channels
■ Technical specifications
Article number 6ES7550-1AA01-0AB0 Article number 6ES7550-1AA01-0AB0
S7-1500, TM Count 2x24V S7-1500, TM Count 2x24V
Digital inputs Switching frequency
Number of digital inputs 6; 3 per channel • with resistive load, max. 10 kHz
Digital inputs, parameterizable Yes • with inductive load, max. 0.5 Hz; Acc. to IEC 60947-5-1, DC-13;
Input characteristic curve in Yes observe derating curve
accordance with IEC 61131, type 3 • on lamp load, max. 10 Hz
■ Technical specifications
Article number 6ES7550-1AA01-0AB0 Article number 6ES7550-1AA01-0AB0
S7-1500, TM Count 2x24V S7-1500, TM Count 2x24V
Integrated Functions Potential separation
Counter Yes Potential separation channels
• Number of counters 2 • between the channels and Yes
• Counting frequency, max. 800 kHz; with quadruple evaluation backplane bus
Fast mode Yes Ambient conditions
Counting functions
• Can be used with TO Yes
Ambient temperature during
operation 4
High_Speed_Counter • horizontal installation, min. -30 °C
• Continuous counting Yes • horizontal installation, max. 60 °C; Please note derating
for inductive loads
• Counter response parameterizable Yes
• vertical installation, min. -30 °C
• Hardware gate via digital input Yes
• vertical installation, max. 40 °C; Please note derating
• Software gate Yes for inductive loads
• Event-controlled stop Yes Altitude during operation
• Synchronization via digital input Yes relating to sea level
• Counting range, parameterizable Yes • Installation altitude above sea level, 5 000 m; restrictions for installation
max. altitudes > 2 000 m, see ET 200MP
Comparator system manual
- Number of comparators 2; Per channel Decentralized operation
- Direction dependency Yes to SIMATIC S7-300 Yes
- Can be changed from Yes to SIMATIC S7-400 Yes
user program
to SIMATIC S7-1200 Yes
Position detection
to SIMATIC S7-1500 Yes
• Incremental acquisition Yes
to standard PROFIBUS master Yes
• Suitable for S7-1500 Motion Control Yes
to standard PROFINET controller Yes
• Suitable for Simotion Yes
Dimensions
Measuring functions
Width 35 mm
• Measuring time, parameterizable Yes
Height 147 mm
• Dynamic measurement period Yes
adjustment Depth 129 mm
• Number of thresholds, 2 Weights
parameterizable Weight, approx. 250 g
Measuring range
- Frequency measurement, min. 0.04 Hz
- Frequency measurement, max. 800 kHz
- Cycle duration measurement, min. 1.25 µs
- Cycle duration measurement, max. 25 s
Accuracy
- Frequency measurement 100 ppm; depending on measuring
interval and signal evaluation
- Cycle duration measurement 100 ppm; depending on measuring
interval and signal evaluation
- Velocity measurement 100 ppm; depending on measuring
interval and signal evaluation
■ Overview
• 2-channel counter and position detection module with RS 422
interface
• Extensive parameterization options for optimum task-specific
adaptation
• Reduces load on controller due to preprocessing on the module
• Position detection with incremental and SSI absolute encoders
• Speed and time period measuring
4 • Storage and comparison functions
• Connection of encoders with RS 422 signals or 5V-TTL signals
■ Technical specifications
Article number 6ES7551-1AB00-0AB0 Article number 6ES7551-1AB00-0AB0
S7-1500, TM Posinput 2 S7-1500, TM Posinput 2
General information Installation type/mounting
Product type designation TM PosInput 2 Rail mounting Yes; S7-1500 mounting rail
Product function Supply voltage
• I&M data Yes; I&M0 to I&M3 Load voltage L+
• Isochronous mode Yes • Rated value (DC) 24 V
Engineering with • Reverse polarity protection Yes
• STEP 7 TIA Portal configurable/ V12 (FW V1.0) ... V15 (FW V1.3)/ Encoder supply
integrated from version V12 (FW V1.0), V13 (FW V1.1) Number of outputs 4; One 5V and 24V encoder supply
• PROFIBUS from GSD version/ GSD Revision 5 per channel
GSD revision 5 V encoder supply
• PROFINET from GSD version/ V2.3 / - •5V Yes; 5.2 V ±2 %
GSD revision
• Short-circuit protection Yes
• Output current, max. 300 mA; Per channel
■ Technical specifications
Article number 6ES7551-1AB00-0AB0 Article number 6ES7551-1AB00-0AB0
S7-1500, TM Posinput 2 S7-1500, TM Posinput 2
24 V encoder supply Output delay with resistive load
• 24 V Yes; L+ (-0.8 V) • "0" to "1", max. 50 µs
• Short-circuit protection Yes • "1" to "0", max. 50 µs
• Output current, max. 300 mA; Per channel Switching frequency
Digital inputs • with resistive load, max. 10 kHz
Number of digital inputs
Digital inputs, parameterizable
4; 2 per channel
Yes
• with inductive load, max. 0.5 Hz; Acc. to IEC 60947-5-1, DC-13;
observe derating curve 4
Input characteristic curve in Yes • on lamp load, max. 10 Hz
accordance with IEC 61131, type 3 Total current of the outputs
Digital input functions, • Current per module, max. 2A
parameterizable Encoder signals, incremental
• Gate start/stop Yes; only for pulse and incremental encoder (symmetrical)
encoders • Input frequency, max. 1 MHz
• Capture Yes • Counting frequency, max. 4 MHz; with quadruple evaluation
• Synchronization Yes; only for pulse and incremental • Cable length, shielded, max. 32 m; at 1 MHz
encoders
• Signal filter, parameterizable Yes
• Freely usable digital input Yes
• Incremental encoder with Yes
Input voltage A/B tracks, 90° phase offset
• Type of input voltage DC • Incremental encoder with Yes
• Rated value (DC) 24 V A/B tracks, 90° phase offset
• for signal "0" -5 ... +5 V and zero track
• for signal "1" +11 to +30V • pulse encoder Yes
• permissible voltage at input, min. -30 V; -5 V continuous, • Pulse encoder with direction Yes
-30 V brief reverse polarity protection • pulse encoder with one impulse Yes
• permissible voltage at input, max. 30 V signal per count direction
Input current Encoder signals, incremental
encoder (asymmetrical)
• for signal "1", typ. 2.5 mA
• Input voltage 5 V TTL (push-pull encoders only)
Input delay
(for rated value of input voltage) • Input frequency, max. 1 MHz
for standard inputs • Counting frequency, max. 4 MHz; with quadruple evaluation
- parameterizable Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / • Signal filter, parameterizable Yes
3.2 / 12.8 / 20 ms • Incremental encoder with Yes
- at "0" to "1", min. 6 µs; for parameterization "none" A/B tracks, 90° phase offset
- at "1" to "0", min. 6 µs; for parameterization "none" • Incremental encoder with Yes
A/B tracks, 90° phase offset
for technological functions and zero track
- parameterizable Yes • pulse encoder Yes
Digital outputs • pulse encoder with direction Yes
Type of digital output Transistor • pulse encoder with one impulse Yes
Number of digital outputs 4; 2 per channel signal per count direction
Digital outputs, parameterizable Yes Encoder signals, absolute encoder
(SSI)
Short-circuit protection Yes; electronic/thermal
• Input signal to RS-422
Limitation of inductive shutdown L+ (-33 V)
voltage to • Telegram length, parameterizable 10 ... 40 bit
Controlling a digital input Yes • Clock frequency, max. 2 MHz; 125 kHz, 250 kHz, 500 kHz,
1 MHz, 1.5 MHz or 2 MHz
Digital output functions,
parameterizable • Binary code Yes
• Switching tripped by comparison Yes • Gray code Yes
values • Cable length, shielded, max. 320 m; Cable length, RS-422 SSI
• Freely usable digital output Yes absolute encoders, Siemens type
6FX2001-5, 24 V supply:
Switching capacity of the outputs 125 kHz, 320 meters shielded, max.;
• with resistive load, max. 0.5 A; Per digital output 250 kHz, 160 meters shielded, max.;
500 kHz, 60 meters shielded, max.;
• on lamp load, max. 5W
1 MHz, 20 meters shielded, max.
Load resistance range 1.5 MHz, 10 meters shielded, max.;
• lower limit 48 Ω 2 MHz, 8 meters shielded, max.
• upper limit 12 kΩ • Parity bit, parameterizable Yes
Output voltage • Monoflop time 16, 32, 48, 64 µs & automatic
• Type of output voltage DC • Multiturn Yes
• for signal "1", min. 23.2 V; L+ (-0.8 V) • Singleturn Yes
Output current Interface types
• for signal "1" rated value 0.5 A; Per digital output • TTL 5 V Yes; push-pull encoders only
• for signal "0" residual current, max. 0.5 mA • RS 422 Yes
■ Technical specifications
Article number 6ES7551-1AB00-0AB0 Article number 6ES7551-1AB00-0AB0
S7-1500, TM Posinput 2 S7-1500, TM Posinput 2
Isochronous mode Measuring functions
Filtering and processing time (TCI), 130 µs; • Measuring time, parameterizable Yes
min. only for pulse and incremental • Dynamic measurement period Yes
encoders adjustment
Bus cycle time (TDP), min. 250 µs • Number of thresholds, 2
parameterizable
4
Interrupts/diagnostics/
status information Measuring range
Alarms - Frequency measurement, min. 0.04 Hz
• Diagnostic alarm Yes - Frequency measurement, max. 4 MHz
• Hardware interrupt Yes - Cycle duration measurement, min. 0.25 µs
Diagnoses - Cycle duration measurement, max. 25 s
• Monitoring the supply voltage Yes Accuracy
• Wire-break Yes - Frequency measurement 100 ppm; depending on measuring
• Short-circuit Yes interval and signal evaluation
• A/B transition error at incremental Yes - Cycle duration measurement 100 ppm; depending on measuring
encoder interval and signal evaluation
• Telegram error at SSI encoder Yes - Velocity measurement 100 ppm; depending on measuring
Diagnostics indication LED interval and signal evaluation
• RUN LED Yes; green LED Potential separation
• ERROR LED Yes; red LED Potential separation channels
• MAINT LED Yes; Yellow LED • between the channels and Yes
backplane bus
• Monitoring of the supply voltage Yes; green LED
(PWR-LED) Ambient conditions
• Channel status display Yes; green LED Ambient temperature during
operation
• for channel diagnostics Yes; red LED
• horizontal installation, min. 0 °C
Integrated Functions
• horizontal installation, max. 60 °C; Please note derating for
Counter Yes inductive loads
• Number of counters 2 • vertical installation, min. 0 °C
• Counting frequency, max. 4 MHz; with quadruple evaluation • vertical installation, max. 40 °C; Please note derating for
Counting functions inductive loads
• Can be used with TO Yes; only for pulse and incremental Altitude during operation relating to
High_Speed_Counter encoders sea level
• Continuous counting Yes • Installation altitude above sea level, 5 000 m; restrictions for installation
max. altitudes > 2 000 m, see ET 200MP
• Counter response parameterizable Yes system manual
• Hardware gate via digital input Yes Decentralized operation
• Software gate Yes to SIMATIC S7-300 Yes
• Event-controlled stop Yes to SIMATIC S7-400 Yes
• Synchronization via digital input Yes to SIMATIC S7-1200 Yes
• Counting range, parameterizable Yes to SIMATIC S7-1500 Yes
Comparator to standard PROFIBUS master Yes; FW V1.1 and higher
- Number of comparators 2; Per channel to standard PROFINET controller Yes
- Direction dependency Yes Dimensions
- Can be changed from user Yes Width 35 mm
program
Height 147 mm
Position detection
Depth 129 mm
• Incremental acquisition Yes
Weights
• Absolute acquisition Yes
Weight, approx. 325 g
• Suitable for S7-1500 Motion Control Yes
■ Technical specifications
Article number 6ES7552-1AA00-0AB0 Article number 6ES7552-1AA00-0AB0
S7-1500, TM Timer DIDQ 16x24V S7-1500, TM Timer DIDQ 16x24V
General information Input delay
Product type designation TM Timer DIDQ 16x24V (for rated value of input voltage)
Product function • Minimum pulse width for program 3 µs for parameterization "none"
reactions
• I&M data Yes; I&M 0
for standard inputs
• Isochronous mode Yes
- parameterizable Yes; none / 0.05 / 0.1 / 0.4 / 0.8 ms
4 Engineering with
• STEP 7 TIA Portal configurable/ V13 Update 3
- at "0" to "1", min. 4 µs; for parameterization "none"
integrated from version - at "1" to "0", min. 4 µs; for parameterization "none"
Installation type/mounting Digital outputs
Rail mounting Yes; S7-1500 mounting rail Type of digital output Transistor
Load voltage 1L+ Number of digital outputs 16; max. depending on
parameterization
• Rated value (DC) 24 V
• in groups of 8
• Reverse polarity protection Yes; against destruction
Digital outputs, parameterizable Yes
Load voltage 2L+
Short-circuit protection Yes; electronic/thermal
• Rated value (DC) 24 V
Limitation of inductive shutdown -0.8 V
• Reverse polarity protection Yes; against destruction voltage to
Encoder supply Controlling a digital input Yes
Number of outputs 8; max. depending on Digital output functions,
parameterization parameterizable
24 V encoder supply • Digital output with time stamp Yes
• 24 V Yes; L+ (-0.8 V) - Number, max. 16
• Short-circuit protection Yes • PWM output Yes
• Output current, max. 1.2 A; Total current of all encoders / - Number, max. 16
channels, max. 0.5 A per output
• Digital output with oversampling Yes
Digital inputs
- Number, max. 16
Number of digital inputs 8; max. depending on
parameterization Switching capacity of the outputs
• in groups of 8 • with resistive load, max. 0.5 A; 0.1 A with High Speed output
Digital inputs, parameterizable Yes • on lamp load, max. 5 W; 1 W with High Speed output
Input characteristic curve in Yes Load resistance range
accordance with IEC 61131, type 3 • lower limit 48 Ω; 240 ohm with High Speed
Digital input functions, output
parameterizable • upper limit 12 kΩ
• Digital input with time stamp Yes Output voltage
- Number, max. 8 • Type of output voltage DC
• Counter Yes • for signal "0", max. 1 V; With High Speed output
- Number, max. 4 • for signal "1", min. 23.2 V; L+ (-0.8 V)
• Counter for incremental encoder Yes Output current
- Number, max. 4 • for signal "1" rated value 0.5 A; 0.1 A with High Speed output,
• Digital input with oversampling Yes observe derating
- Number, max. 8 • for signal "0" residual current, max. 0.5 mA
• HW enable for digital input Yes Output delay with resistive load
- Number, max. 4 • "0" to "1", max. 1 µs; With High Speed output,
5 µs with Standard output
• HW enable for digital output Yes
• "1" to "0", max. 1 µs; With High Speed output,
- Number, max. 4 6 µs with Standard output
Input voltage Switching frequency
• Type of input voltage DC • with resistive load, max. 10 kHz
• Rated value (DC) 24 V • on lamp load, max. 10 Hz
• for signal "0" -5 ... +5 V Total current of the outputs
• for signal "1" +11 to +30V • Current per group, max. 4A
• permissible voltage at input, min. -30 V; -5 V continuous, • Current per module, max. 8 A; Observe derating
-30 V brief reverse polarity protection
• permissible voltage at input, max. 30 V
Input current
• for signal "1", typ. 2.5 mA
■ Technical specifications
Article number 6ES7552-1AA00-0AB0 Article number 6ES7552-1AA00-0AB0
S7-1500, TM Timer DIDQ 16x24V S7-1500, TM Timer DIDQ 16x24V
Encoder Integrated Functions
Connectable encoders Counter
• Incremental encoder (asymmetrical) Yes • Number of counters 4
• 24 V initiator Yes • Counting frequency, max. 200 kHz; with quadruple evaluation
• 2-wire sensor Yes Counting functions
- permissible quiescent current
(2-wire sensor), max.
1.5 mA • Continuous counting
Potential separation
Yes
4
Encoder signals, incremental Potential separation channels
encoder (asymmetrical)
• between the channels and Yes
• Input frequency, max. 50 kHz backplane bus
• Counting frequency, max. 200 kHz; with quadruple evaluation Ambient conditions
• Cable length, shielded, max. 600 m; Depending on input Ambient temperature during
frequency, encoder and cable operation
quality; max. 200 m at 50 kHz
• horizontal installation, min. 0 °C
• Incremental encoder with A/B Yes
tracks, 90° phase offset • horizontal installation, max. 60 °C
• pulse encoder Yes • vertical installation, min. 0 °C
Encoder signal 24 V • vertical installation, max. 40 °C; Observe derating
- permissible voltage at input, min. -30 V Decentralized operation
- permissible voltage at input, max. 30 V to SIMATIC S7-1500 Yes
Interface types Dimensions
• Input characteristic curve in Yes Width 35 mm
accordance with IEC 61131, type 3 Height 147 mm
Isochronous mode Depth 129 mm
Bus cycle time (TDP), min. 250 µs Weights
Interrupts/diagnostics/ Weight, approx. 320 g
status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
• Diagnostic alarm Yes
Diagnoses
• Monitoring the supply voltage Yes
• Short-circuit Yes
Diagnostics indication LED
• RUN LED Yes; green LED
• ERROR LED Yes; red LED
• MAINT LED Yes; Yellow LED
• Monitoring of the supply voltage Yes; green LED
(PWR-LED)
• Channel status display Yes; green LED
• for channel diagnostics Yes; red LED
■ Overview
• 4-channel interface module for PTO (Pulse Train Output) • 3 signal types can be configured:
• 3 signal interfaces can be configured for speed and direction: - Pulse and direction
- 24 V asymmetrical up to 200 kHz - Pulses for forward movement and pulses for backwards
- RS 422, 5 V symmetrical up to 1 MHz movement
- TTL 5 V asymmetrical up to 200 kHz - 2 phase-shifted signals, with simple or quadruple evaluation
• Supported technology objects:
- Speed controlled axis (S7-1500, S7-1500T)
- Positioning axis (S7-1200, S7-1500, S7-1500T)
■ Technical specifications
Article number 6ES7553-1AA00-0AB0 Article number 6ES7553-1AA00-0AB0
S7-1500, TM PTO4 S7-1500, TM PTO4
General information Digital inputs
Product type designation TM PTO 4 Number of digital inputs 12; 3 per channel, of which 1 DIQ
Number of channels 4; Axes Digital inputs, parameterizable Yes
Product function Input characteristic curve in Yes
• I&M data Yes; I&M0 to I&M3 accordance with IEC 61131, type 3
• Isochronous mode Yes Digital input functions,
parameterizable
Engineering with
• Synchronization Yes
• STEP 7 TIA Portal configurable/ STEP 7 V14 or higher
integrated from version Input voltage
• STEP 7 configurable/integrated from V5.5 SP3 with GSD file / - • Type of input voltage DC
version • Rated value (DC) 24 V
• PROFINET from GSD version/ GSDML V2.32 • for signal "0" -5 ... +5 V
GSD revision • for signal "1" +11 to +30V
Installation type/mounting • permissible voltage at input, min. -5 V
Rail mounting Yes; S7-1500 mounting rail • permissible voltage at input, max. 30 V
Supply voltage Input current
Load voltage L+ • for signal "1", typ. 2.5 mA
• Rated value (DC) 24 V
• Reverse polarity protection Yes
■ Technical specifications
Article number 6ES7553-1AA00-0AB0 Article number 6ES7553-1AA00-0AB0
S7-1500, TM PTO4 S7-1500, TM PTO4
Input delay Isochronous mode
(for rated value of input voltage) Bus cycle time (TDP), min. 250 µs; 375 µs if all 4 channels
for standard inputs are used
- parameterizable Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / Interrupts/diagnostics/
3.2 / 12.8 / 20 ms status information
- at "0" to "1", min. 4 µs; for parameterization "none" Diagnostics function Yes
- at "1" to "0", min. 4 µs; for parameterization "none" Alarms 4
for technological functions • Diagnostic alarm Yes
- parameterizable Yes Diagnoses
Digital outputs • Monitoring the supply voltage Yes
Number of digital outputs 12; 3 per channel, of which 1 DIQ • Short-circuit Yes; Thermal overload protection
Digital outputs, parameterizable Yes • Group error Yes
Short-circuit protection Yes; electronic/thermal Diagnostics indication LED
Controlling a digital input Yes • RUN LED Yes; green LED
Digital output functions, • ERROR LED Yes; red LED
parameterizable • MAINT LED Yes; Yellow LED
• PTO (pulse train output) • Monitoring of the supply voltage Yes; green LED
signal interface (PWR-LED)
- 24 V asymmetrical Yes • Channel status display Yes; green LED
- RS 422 symmetrical Yes • for channel diagnostics Yes; red LED
- TTL (5 V) asymmetrical Yes Potential separation
• PTO (pulse train output) signal type Potential separation channels
- Pulse and direction Yes • between the channels and Yes
- Count up, count down Yes backplane bus
- Incremental encoder (A, B phase Yes Ambient conditions
shift) Ambient temperature during
- Incremental encoder (A, B phase Yes operation
shift, quadruple) • horizontal installation, min. 0 °C
Switching capacity of the outputs • horizontal installation, max. 60 °C; Observe derating
• with resistive load, max. 0.1 A; 0.5 A for DIQn.2 • vertical installation, min. 0 °C
• on lamp load, max. 1 W; 5 W for DIQn.2 • vertical installation, max. 40 °C; Observe derating
Load resistance range Altitude during operation relating
• lower limit 240 Ω; 48 ohms for DIQn.2 to sea level
• upper limit 12 kΩ • Installation altitude above sea level, 5 000 m; restrictions for installation
Output voltage max. altitudes > 2 000 m, see
ET 200MP system manual
• Type of output voltage DC
Decentralized operation
• for signal "1", min. 23.2 V; L+ (-0.8 V), L+ (-1.3 V) for
DIQn.2 to SIMATIC S7-300 Yes; Via control and feedback
interface
Output current
to SIMATIC S7-400 Yes; Via control and feedback
• for signal "1" rated value 0.1 A; 0.5 A for DIQn.2 interface
• for signal "0" residual current, max. 0.5 mA to SIMATIC S7-1200 Yes
Output delay with resistive load to SIMATIC S7-1500 Yes
• "0" to "1", typ. 1 µs; 28 µs for DIQn.2 to standard PROFINET controller Yes; Via control and feedback
• "1" to "0", typ. 1 µs; 25 µs for DIQn.2 interface
Switching frequency Dimensions
• with resistive load, max. 1 kHz; For DIQn.2 Width 35 mm
• with inductive load, max. 0.5 Hz; According to IEC 60947-5-1, Height 147 mm
DC-13, for DIQn.2 Depth 129 mm
• on lamp load, max. 10 Hz; For DIQn.2 Weights
• For signal interface 24 V 200 kHz; With DQn.0 and DQn.1 Weight, approx. 300 g
asymmetrical
• For signal interface RS 422 1 MHz
symmetrical
• For signal interface TTL (5 V) 200 kHz
asymmetrical
■ Overview
Accessories Commissioning
SIWAREX JB junction box, 7MH5001-0AA20 Commissioning charge 9LA1110-8SN50-0AA0
aluminum housing for one static scale with
SIWAREX module
For connecting up to 4 load cells in
parallel, and for connecting multiple (Flat charge for travel and setup
junction boxes. must be ordered separately)
SIWAREX JB junction box, 7MH5001-0AA00 Scope:
stainless steel housing • Recording of data
For connecting up to 4 load cells
in parallel.
• Checking of mechanical
installation of the scale
• Checking of electrical wiring
4
SIWAREX JB junction box, 7MH5001-0AA01 and function
stainless steel housing (ATEX) • Static adjustment of the scale
Requirements:
For parallel connection of up to
• Mechanical design functional
4 load cells (for zone allocation,
• Modules electrically wired
see manual or type-examination
and tested
certificate).
• Calibration weights available
SIWAREX IS Ex interface • Free access to scale
For intrinsically safe connection Flat charge for travel and setup 9LA1110-8RA10-0AA0
of load cells. With ATEX approval in Germany
(not UL/FM). Suitable for
SIWAREX electronic weighing
systems. Compatibility of load cells
must be checked separately.
• Short-circuit current < 199 mA DC 7MH4710-5BA
• Short-circuit current < 137 mA DC 7MH4710-5CA
Cable (optional)
Cable Li2Y 1 × 2 × 0.75 ST + 2 ×
(2 × 0.34 ST) – CY
For connecting SIWAREX electronic
weighing systems to junction box
(JB), extension box (EB) and Ex
interface or between two EBs.
For permanent installation.
Occasional bending is possible.
External diameter:
approx. 10.8 mm (0.43 inch)
Permissible ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Sold by the meter.
• Sheath color: orange 7MH4702-8AG
• For hazardous atmospheres. 7MH4702-8AF
Sheath color: blue.
■ Technical specifications
SIWAREX WP521 ST / WP522 ST SIWAREX WP521 ST / WP522 ST
Weighing modes • Non-automatic scales, e.g. platform Parameter assignment • Using function block in
and hopper scales SIMATIC S7-1500 and HMI
• Using SIWATOOL V7
Ports • 1 × SIMATIC S7-1500 system bus • Using Modbus TCP/IP
• 1 × Ethernet • Using Modbus RTU
(SIWATOOL, Modbus TCP/IP)
• 1 × RS 485 per channel Remote display (see accessories)
(Modbus RTU or remote display)
• 3 × digital inputs per channel Connection Via RS 485
(24 V DC) Display Additional display for weight value
• 4 x digital outputs
(24 V DC short-circuit proof) Measuring accuracy
per channel
Error limit according to DIN 1319-1 of 0.05%
Functions • 3 limits full-scale value at 20 °C ± 10 K
• Zeroing (68 °F ± 10 K)
• Tare
Internal resolution Up to ± 4 million parts
• Tare specification
• Zero adjustment Number of measurements/second 100 or 120 (selectable)
• Trace function for signal analysis
• Internal restore point Filter • Low-pass filter 0.05 ... 50 Hz
• SIMATIC S7-1500 integrated • Average value filter
and/or stand-alone operation
■ Technical specifications
SIWAREX WP521 ST / WP522 ST SIWAREX WP521 ST / WP522 ST
Weighing functions Certificates • ATEX Zone 2
• UL
Weight values • Gross • KCC
• Net • EAC
• Tare • RCM
Limit values • 2 × min/max • FM
• 1 × empty • IECEx
Tare specification Per command Max. power consumption WP521 ST / 120 mA / 200 mA
WP522 ST
Compatible sensors Analog load cells /
full-bridge strain gauges (1-4 mV/V) Max. power consumption 35 mA @ 15 V
in 4-wire or 6-wire system SIMATIC Bus
4
Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under
max. condensation conditions)
Resistance
Coolants and lubricants
• 2-channel high-speed counter module - Resistant to commercially Yes; Incl. diesel and oil droplets in
available coolants and lubricants the air
• With comprehensive parameterization options for an optimum Use in stationary industrial systems
adaptation to the task and reduction of control load
- to biologically active substances Yes; Class 3B2 mold, fungus and dry
• Speed and time period measuring according to EN 60721-3-3 rot spores (with the exception of
fauna); Class 3B3 on request
• Storage and comparison functions
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt
• Connection of 24 V encoders according to EN 60721-3-3 spray acc. to EN 60068-2-52
(severity degree 3); *
Note:
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
SIPLUS extreme products are based on SIMATIC standard according to EN 60721-3-3
products. The contents listed here were taken from the Use on ships/at sea
respective standard products. SIPLUS extreme-specific - to biologically active substances Yes; Class 6B2 mold and fungal
information was added. according to EN 60721-3-6 spores (excluding fauna);
Class 6B3 on request
■ Ordering data Article No. - to chemically active substances
according to EN 60721-3-6
Yes; Class 6C3 (RH < 75 %) incl. salt
spray acc. to EN 60068-2-52
(severity degree 3); *
SIPLUS TM Count 2x24V 6AG1550-1AA00-7AB0
counter module - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
(Extended temperature range and
exposure to media) Usage in industrial process
technology
With 2-channels, max. 200 kHz; - Against chemically active Yes; Class 3 (excluding
for 24 V encoder substances acc. to EN 60654-4 trichlorethylene)
Accessories See SIMATIC S7-1500, - Environmental conditions for Yes; Level GX group A/B
TM Count 2x24V counter module, process, measuring and control (excluding trichlorethylene;
page 4/139 systems acc. to ANSI/ISA-71.04 harmful gas concentrations
up to the limits of EN 60721-3-3
class 3C4 permissible);
■ Technical specifications level LC3 (salt spray) and
level LB3 (oil)
Article number 6AG1550-1AA00-7AB0 Remark
Based on 6ES7550-1AA00-0AB0 - Note regarding classification of * The supplied plug covers must
environmental conditions acc. to remain in place over the unused
SIPLUS S7-1500 TM Count 2X24V EN 60721, EN 60654-4 and interfaces during operation!
Ambient conditions ANSI/ISA-71.04
Ambient temperature during Conformal coating
operation • Coatings for printed circuit board Yes; Class 2 for high reliability
• horizontal installation, min. -40 °C; = Tmin assemblies acc. to EN 61086
(incl. condensation/frost); • Protection against fouling acc. to Yes; Type 1 protection
start-up @ -25 °C EN 60664-3
• horizontal installation, max. 70 °C; = Tmax; note derating for • Military testing according to Yes; Discoloration of coating
inductive loads; > +60 °C total MIL-I-46058C, Amendment 7 possible during service life
current of the encoder supply max.
0.5 A, total current of the outputs • Qualification and Performance of Yes; Conformal coating, Class A
max. 1 A Electrical Insulating Compound for
Printed Board Assemblies
• vertical installation, min. -40 °C; = Tmin; Startup @ -25 °C according to IPC-CC-830A
• vertical installation, max. 40 °C; Please note derating for
inductive loads
4
Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation / frost
accordance with IEC 60068-2-38, (no commissioning in bedewed
max. state), horizontal installation
Resistance
Coolants and lubricants
• 2-channel counter and position detection module with - Resistant to commercially Yes; Incl. diesel and oil droplets in
available coolants and lubricants the air
RS422 interface
Use in stationary industrial systems
• Comprehensive parameterization options for optimum
- to biologically active substances Yes; Class 3B2 mold, fungus and dry
adaptation to the task according to EN 60721-3-3 rot spores (with the exception of
• Offloading of controller through preprocessing on the module fauna); Class 3B3 on request
• Position detection with incremental and SSI absolute-value - to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52
encoders (severity degree 3); *
• Speed and time period measuring - to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
• Storage and comparison functions according to EN 60721-3-3
Use on ships/at sea
• Connection of encoders with RS422 signals or 5 V TTL signals
- to biologically active substances Yes; Class 6B2 mold and fungal
Note: according to EN 60721-3-6 spores (excluding fauna);
Class 6B3 on request
SIPLUS extreme products are based on SIMATIC standard
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt
products. The contents listed here were taken from the according to EN 60721-3-6 spray acc. to EN 60068-2-52
respective standard products. SIPLUS extreme-specific (severity degree 3); *
information was added. - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
■ Ordering data Article No. Usage in industrial process
technology
SIPLUS TM PosInput 2 counter 6AG1551-1AB00-7AB0 - Against chemically active Yes; Class 3 (excluding
and positioning module substances acc. to EN 60654-4 trichlorethylene)
(extended temperature range and - Environmental conditions for Yes; Level GX group A/B
medial exposure) process, measuring and control (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations
With 2-channels, max. 1 MHz up to the limits of EN 60721-3-3
counter frequency; for SSI and class 3C4 permissible);
incremental encoders with RS422 level LC3 (salt spray) and
or 5 V TTL interface level LB3 (oil)
Accessories See SIMATIC S7-1500, TM PosInput 2 Remark
counter and positioning module, - Note regarding classification of * The supplied plug covers must
page 4/142 environmental conditions acc. to remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation!
ANSI/ISA-71.04
■ Technical specifications Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability
Article number 6AG1551-1AB00-7AB0 assemblies acc. to EN 61086
Based on 6ES7551-1AB00-0AB0 • Protection against fouling acc. to Yes; Type 1 protection
SIPLUS S7-1500 TM POSINPUT 2 EN 60664-3
Ambient conditions • Military testing according to Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life
Ambient temperature during
operation • Qualification and Performance of Yes; Conformal coating, Class A
Electrical Insulating Compound for
• horizontal installation, min. -40 °C; = Tmin
Printed Board Assemblies
(incl. condensation/frost);
according to IPC-CC-830A
start-up @ -25 °C
• horizontal installation, max. 70 °C; Please note derating for
inductive loads
• vertical installation, min. 0 °C
• vertical installation, max. 40 °C; Please note derating for
inductive loads
■ Overview
• Modules for serial communication connections, scaled
according to interface types, protocols, and performance
• 4 versions with different physical transmission characteristics:
- RS 232C, max. 19.2 Kbit/s
- RS 232C, max.115.2 Kbit/s
- RS 422/RS 485, max. 19.2 Kbit/s
- RS 422/RS 485, max. 115.2 Kbit/s
• Protocols supported
- Freeport: User-parameterizable telegram format for
universal communication
4
- 3964(R) for improved transmission reliability
- Modbus RTU Master
- Modbus RTU Slave
- USS, implemented through instructions
■ Technical specifications
Article number 6ES7540-1AD00-0AA0 6ES7541-1AD00-0AB0 6ES7540-1AB00-0AA0 6ES7541-1AB00-0AB0
S7-1500, CM PTP RS232 BA S7-1500, CM PTP RS232 HF S7-1500, CM PTP S7-1500, CM PTP
RS422/485 BA RS422/485 HF
General information
Product type designation CM PtP RS 232 BA CM PtP RS 232 HF CM PtP RS 422 / 485 BA CM PtP RS 422 / 485 HF
Product function
• I&M data Yes; I&M 0 Yes; I&M 0 Yes; I&M 0 Yes; I&M 0
4 • Fast startup
Engineering with
Yes Yes Yes Yes
• STEP 7 TIA Portal configurable/ V12 / V12 V12 / V12 V12 / V12 V12 / V12
integrated from version
• STEP 7 configurable/integrated V5.5 SP2 with GSD file V5.5 SP2 with GSD file V5.5 SP2 with GSD file V5.5 SP2 with GSD file
from version
• PROFINET from GSD version/ V2.3 V2.3 / - V2.3 V2.3 / -
GSD revision
Installation type/mounting
Rail mounting Yes; S7-1500 mounting rail Yes; S7-1500 mounting rail Yes; S7-1500 mounting rail Yes; S7-1500 mounting rail
Interface types
RS 232
• Transmission rate, max. 19.2 kbit/s 115.2 kbit/s
• Cable length, max. 15 m 15 m
• RS 232 auxiliary signals RTS, CTS, DTR, DSR, RI, RTS, CTS, DTR, DSR, RI,
DCD DCD
RS 485
• Transmission rate, max. 19.2 kbit/s 115.2 kbit/s
• Cable length, max. 1 200 m 1 200 m
RS 422
• Transmission rate, max. 19.2 kbit/s 115.2 kbit/s
• Cable length, max. 1 200 m 1 200 m
• 4-wire full duplex connection Yes Yes
• 4-wire multipoint connection No No
Protocols
Integrated protocols
Freeport
- Telegram length, max. 1 kbyte 4 kbyte 1 kbyte 4 kbyte
- Bits per character 7 or 8 7 or 8 7 or 8 7 or 8
- Number of stop bits 1 or 2 bit 1 or 2 bit 1 or 2 bit 1 or 2 bit
- Parity None, even, odd, always 1, None, even, odd, always 1, None, even, odd, always 1, None, even, odd, always 1,
always 0, any always 0, any always 0, any always 0, any
3964 (R)
- Telegram length, max. 1 kbyte 4 kbyte 1 kbyte 4 kbyte
- Bits per character 7 or 8 7 or 8 7 or 8 7 or 8
- Number of stop bits 1 or 2 bit 1 or 2 bit 1 or 2 bit 1 or 2 bit
- Parity None, even, odd, always 1, None, even, odd, always 1, None, even, odd, always 1, None, even, odd, always 1,
always 0, any always 0, any always 0, any always 0, any
Modbus RTU master
- Address area 1 to 247, extended 1 to 1 to 247, extended 1 to
65535 65535
- Number of slaves, max. 1 32
MODBUS RTU slave
- Address area 1 to 247, extended 1 to 1 to 247, extended 1 to
65535 65535
Telegram buffer
• Buffer memory for telegrams 2 kbyte 8 kbyte 2 kbyte 8 kbyte
• Number of telegrams which can be 255 255 255 255
buffered
■ Technical specifications
Article number 6ES7540-1AD00-0AA0 6ES7541-1AD00-0AB0 6ES7540-1AB00-0AA0 6ES7541-1AB00-0AB0
S7-1500, CM PTP RS232 BA S7-1500, CM PTP RS232 HF S7-1500, CM PTP S7-1500, CM PTP
RS422/485 BA RS422/485 HF
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes Yes Yes
Alarms
• Diagnostic alarm Yes Yes Yes Yes
• Hardware interrupt No No No No 4
Diagnoses
• Wire-break Yes Yes Yes Yes
Diagnostics indication LED
• RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
• ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
• Receive RxD Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
• Transmit TxD Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
Potential separation
between backplane bus and interface Yes Yes Yes Yes
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. 0 °C 0 °C 0 °C 0 °C
• horizontal installation, max. 60 °C 60 °C 60 °C 60 °C
• vertical installation, min. 0 °C 0 °C 0 °C 0 °C
• vertical installation, max. 40 °C 40 °C 40 °C 40 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m; restrictions for 5 000 m; restrictions for 5 000 m; restrictions for 5 000 m; restrictions for
max. installation altitudes installation altitudes installation altitudes installation altitudes
> 2 000 m, see > 2 000 m, see > 2 000 m, see > 2 000 m, see
ET 200MP system manual ET 200MP system manual ET 200MP system manual ET 200MP system manual
Decentralized operation
to SIMATIC S7-300 Yes Yes Yes Yes
to SIMATIC S7-400 Yes Yes Yes Yes
to SIMATIC S7-1500 Yes Yes Yes Yes
to standard PROFINET controller Yes Yes Yes Yes
Dimensions
Width 35 mm 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 127 mm 127 mm 127 mm 127 mm
Weights
Weight, approx. 0.22 kg 0.22 kg 0.22 kg 0.22 kg
■ Technical specifications
Article number 6ES7547-1JF00-0AB0 Article number 6ES7547-1JF00-0AB0
S7-1500, CM 8xIO-Link S7-1500, CM 8xIO-Link
Interrupts/diagnostics/ Ambient conditions
status information Ambient temperature during
Alarms operation
• Diagnostic alarm Yes; The port diagnosis is available • horizontal installation, min. 0 °C
in the IO-Link mode only. • horizontal installation, max. 60 °C; Observe derating
4
Diagnoses • vertical installation, min. 0 °C
• Monitoring the supply voltage Yes • vertical installation, max. 40 °C; Observe derating
• Wire-break Yes Altitude during operation relating to
• Short-circuit Yes sea level
• Group error Yes • Installation altitude above sea level, 5 000 m; Restrictions for installation
Diagnostics indication LED max. altitudes > 2 000 m, see manual
• Monitoring of the supply voltage Yes; green LED Dimensions
(PWR-LED) Width 35 mm
• Channel status display Yes; green LED Height 147 mm
• for channel diagnostics Yes; red LED Depth 129 mm
• for module diagnostics Yes; red LED
Potential separation
Potential separation channels
• between the channels and Yes
backplane bus
CM 1542-5 communications
module
Communications module for 6GK7542-5DX00-0XE0
electrical connection of
SIMATIC S7-1500 to PROFIBUS
as DP master or DP slave;
S7 and PG/OP communication,
data record routing, time
synchronization, diagnostics
4 Accessories
PROFIBUS FastConnect
RS 485 connection plug
With 90° cable outlet;
insulation displacement technology,
max. transmission rate 12 Mbps
• Without PG interface 6ES7972-0BA52-0XA0
• With programming device 6ES7972-0BB52-0XA0
interface
PROFIBUS FC Standard Cable
■ Technical specifications
Article number 6GK7542-5DX00-0XE0 Article number 6GK7542-5DX00-0XE0
product type designation CM 1542-5 product type designation CM 1542-5
ambient conditions performance data S7
ambient temperature communication
• for vertical installation during 0 ... 40 °C number of possible connections for
operation S7 communication
• for horizontally arranged busbars 0 ... 60 °C • maximum 48; depending on the system
during operation upper limit
• during storage -40 ... +70 °C performance data multi-protocol
mode 4
• during transport -40 ... +70 °C
number of active connections with 48
relative humidity multi-protocol mode
• at 25 °C without condensation 95 % performance data telecontrol
during operation maximum
protocol is supported
protection class IP IP20
• TCP/IP No
design, dimensions and weights
product functions management,
module format Compact module S7-1500 single configuration, engineering
width
configuration software
width 35 mm
• required STEP 7 Professional V12 (TIA Portal)
height 142 mm or higher
depth 129 mm identification & maintenance function
net weight 0.4 kg • I&M0 - device-specific information Yes
fastening method • I&M1 – higher level Yes
• S7-1500 rail mounting Yes designation/location designation
product features, product functions, product functions diagnostics
product components general product function web-based Yes; via S7-1500 CPU
number of units diagnostics
• per CPU maximum 8 product functions time
• note depending on CPU type product function pass on time Yes
synchronization
performance data open
communication standards, specifications, approvals
hazardous environments
number of possible connections for 30
open communication by means of certificate of suitability CCC for Yes
SEND/RECEIVE blocks maximum hazardous zone according to GB
standard
data volume
• as user data per connection for open 240 byte
communication by means of
SEND/RECEIVE blocks maximum
performance data PROFIBUS DP
service as DP master
• DPV1 Yes
number of DP slaves
• on DP master operable 125
data volume
• of the address range of the inputs as 8 192 byte
DP master total
• of the address range of the outputs 8 192 byte
as DP master total
• of the address range of the inputs 244 byte
per DP slave
• of the address range of the outputs 244 byte
per DP slave
service as DP slave
• DPV0 Yes
• DPV1 Yes
data volume
• of the address range of the inputs as 240 byte
DP slave total
• of the address range of the outputs 240 byte
as DP slave total
CP 1542-5 communications
processor
Communications module for 6GK7542-5FX00-0XE0
electrical connection of
SIMATIC S7-1500 to PROFIBUS as
DP master or DP slave;
PG/OP communication, time
synchronization, diagnostics;
smaller quantity structure
4 Accessories
PROFIBUS FastConnect
RS 485 connection plug
With 90° cable outlet;
insulation displacement technology,
max. transmission rate 12 Mbps
• Without programming device 6ES7972-0BA52-0XA0
interface
• With programming device 6ES7972-0BB52-0XA0
interface
PROFIBUS FC Standard Cable
kwTt kwTz mtz wnVvw z^Vz\
2-core bus cable, shielded, 6XV1830-0EH10
special design for fast mounting,
nprXWXWX[[
■ Technical specifications
Article number 6GK7542-5FX00-0XE0 Article number 6GK7542-5FX00-0XE0
product type designation CP 1542-5 product type designation CP 1542-5
transfer rate performance data PROFIBUS DP
transfer rate service as DP master
• at the 1st interface acc. to 9.6 kbit/s ... 12 Mbit/s • DPV1 Yes
PROFIBUS number of DP slaves
interfaces • on DP master operable 32
number of interfaces acc. to
Industrial Ethernet
0 data volume
• of the address range of the inputs 2 048 byte
4
number of electrical connections as DP master total
• at the 1st interface acc. to 1 • of the address range of the outputs 2 048 byte
PROFIBUS as DP master total
type of electrical connection • of the address range of the inputs 244 byte
• at the 1st interface acc. to 9-pin Sub-D socket (RS485) per DP slave
PROFIBUS • of the address range of the outputs 244 byte
supply voltage, current per DP slave
consumption, power loss service as DP slave
type of voltage of the supply voltage DC • DPV0 Yes
supply voltage 1 from backplane bus 15 V • DPV1 Yes
relative symmetrical tolerance at DC data volume
• at 15 V 3% • of the address range of the inputs 240 byte
consumed current as DP slave total
• from backplane bus at DC at 15 V 0.1 A • of the address range of the outputs 240 byte
typical as DP slave total
power loss [W] 1.5 W performance data S7
ambient conditions communication
ambient temperature number of possible connections for
S7 communication
• for vertical installation during 0 ... 40 °C
operation • maximum 16; depending on the system
upper limit
• for horizontally arranged busbars 0 ... 60 °C
during operation performance data multi-protocol
mode
• during storage -40 ... +70 °C
number of active connections with 16
• during transport -40 ... +70 °C multi-protocol mode
relative humidity performance data telecontrol
• at 25 °C without condensation 95 % protocol is supported
during operation maximum
• TCP/IP No
protection class IP IP20
product functions management,
design, dimensions and weights configuration, engineering
module format Compact module S7-1500 single configuration software
width
• required STEP 7 Professional V12 SP1
width 35 mm (TIA Portal) or higher
height 142 mm identification & maintenance function
depth 129 mm • I&M0 - device-specific information Yes
net weight 0.27 kg • I&M1 – higher level Yes
fastening method designation/location designation
• S7-1500 rail mounting Yes product functions diagnostics
product features, product functions, product function web-based Yes; via S7-1500 CPU
product components general diagnostics
number of units product functions time
• per CPU maximum 8 product function pass on time Yes
synchronization
• note depending on CPU type
standards, specifications, approvals
hazardous environments
certificate of suitability CCC for Yes
hazardous zone according to
GB standard
CM 1542-1 6GK7542-1AX00-0XE0
communications module
For connecting
SIMATIC S7-1500 to PROFINET IO,
TCP/IP, ISO-on-TCP, UDP,
S7 communication,
IP broadcast/multicast, SNMPV1,
time synchronization via NTP;
2 x RJ45 interface with
4 10/100 Mbps
Accessories
IE FC RJ45 Plug 4 x 2
RJ45 plug-in connector for
Industrial Ethernet
(10/100/1 000 Mbps) with a rugged
metal enclosure and integrated
insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables; 180° cable
outlet; for network components and
CPs/CPUs with Industrial Ethernet
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 interface
UDP • 1 pack = 1 unit 6GK1901-1BB11-2AA0
G_IK10_XX_10363
■ Technical specifications
Article number 6GK7542-1AX00-0XE0 Article number 6GK7542-1AX00-0XE0
product type designation CM 1542-1 product type designation CM 1542-1
transfer rate performance data open
transfer rate communication
• at the 1st interface 10 ... 100 Mbit/s number of possible connections for
open communication
interfaces
• by means of T blocks maximum 64; depending on the system
number of interfaces acc. to 1 upper limit
Industrial Ethernet
number of electrical connections
data volume
• as user data per ISO on TCP 65 536 byte
4
• at the 1st interface acc. to 2 connection for open communication
Industrial Ethernet by means of T blocks maximum
type of electrical connection number of Multicast stations 6
• at the 1st interface acc. to RJ45 port performance data S7
Industrial Ethernet communication
supply voltage, current number of possible connections for
consumption, power loss S7 communication
type of voltage of the supply voltage DC • maximum 64; depending on the system
supply voltage 1 from backplane bus 15 V upper limit
relative symmetrical tolerance at DC performance data multi-protocol
mode
• at 15 V 3%
number of active connections with 64
consumed current multi-protocol mode
• from backplane bus at DC at 15 V 0.22 A performance data PROFINET
typical communication as PN IO controller
power loss [W] 3.3 W product function PROFINET IO Yes
ambient conditions controller
ambient temperature number of PN IO devices on 128
PROFINET IO controller operable total
• for vertical installation during 0 ... 40 °C
operation number of PN IO IRT devices on 64
PROFINET IO controller operable
• for horizontally arranged busbars 0 ... 60 °C
during operation number of external PN IO lines with 10
PROFINET per rack
• during storage -40 ... +70 °C
data volume
• during transport -40 ... +70 °C
• as user data for input variables as 8 Kibyte
relative humidity
PROFINET IO controller maximum
• at 25 °C without condensation 95 %
• as user data for output variables as 8 Kibyte
during operation maximum
PROFINET IO controller maximum
protection class IP IP20
• as user data for input variables per 1 433 byte
design, dimensions and weights PN IO device as PROFINET IO
module format Compact module S7-1500 single controller maximum
width • as user data for output variables per 1 433 byte
width 35 mm PN IO device as PROFINET IO
controller maximum
height 142 mm
• as user data for input variables per 256 byte
depth 129 mm PN IO device for each sub-module
net weight 0.4 kg as PROFINET IO controller
maximum
fastening method
• as user data for output variables per 256 byte
• S7-1500 rail mounting Yes PN IO device for each sub-module
product features, product functions, as PROFINET IO controller
product components general maximum
number of units
• per CPU maximum 8
• note depending on CPU type
■ Technical specifications
Article number 6GK7542-1AX00-0XE0 Article number 6GK7542-1AX00-0XE0
product type designation CM 1542-1 product type designation CM 1542-1
performance data PROFINET product functions routing
communication as PN IO device service routing note IP routing up to 1 Mbps
product function PROFINET IO device Yes product function
data volume • static IP routing Yes
• as user data for input variables as 8 192 byte • static IP routing IPv6 No
PROFINET IO device maximum
4 • as user data for output variables as 8 192 byte
PROFINET IO device maximum
• dynamic IP routing
• dynamic IP routing IPv6
No
No
• as user data for input variables for 256 byte protocol is supported
each sub-module as • RIP v1 No
PROFINET IO device
• RIPv2 No
• as user data for output variables for 256 byte
each sub-module as • RIPnG for IPv6 No
PROFINET IO device • OSPFv2 No
• as user data for the consistency area 256 byte • OSPFv3 for IPv6 No
for each sub-module
• VRRP No
number of submodules per 32
• VRRP for IPv6 No
PROFINET IO-Device
• BGP No
performance data telecontrol
• PPP No
protocol is supported
• PPoE via DSL No
• TCP/IP Yes
product functions redundancy
product functions management,
configuration, engineering product function
product function MIB support Yes • ring redundancy Yes
protocol is supported • redundancy manager Yes
• SNMP v1 Yes protocol is supported Media Yes
Redundancy Protocol (MRP)
• DCP Yes
product functions security
• LLDP Yes
product function
configuration software
• switch-off of non-required services Yes
• required STEP 7 Professional V14 (TIA Portal)
or higher • blocking of communication via No
physical ports
identification & maintenance function
• log file for unauthorized access No
• I&M0 – device-specific information Yes
product functions time
• I&M1 – higher level Yes
designation/location designation product function SICLOCK support Yes
product functions diagnostics product function pass on time Yes
synchronization
product function web-based Yes; via S7-1500 CPU
diagnostics protocol is supported
product functions switch • NTP Yes
product feature switch Yes standards, specifications, approvals
hazardous environments
product function
certificate of suitability CCC for Yes
• switch-managed No
hazardous zone according to GB
• with IRT PROFINET IO switch Yes standard
• configuration with STEP 7 Yes
■ Overview
The CP 1543-1 supports the following communications services:
• PG/OP communication
• S7 communication
• Open user communication (SEND/RECEIVE, FETCH/WRITE)
• IT communication
- FTP functions (File Transfer Protocol FTP/FTPS) for file
management and access to data blocks in the CPU
(client and server function)
- Access (read and write modes) to csv files stored on 4
the memory card of the CPU via FTP(S)
- Sending emails via SMTP or ESMTP with "SMTP-Auth"
for authentication on an email server (also with IPv6)
- Static IP routing with up to 1 Mbps via IPv4 to other
CP 1543-1 / CM 1542-1 units in an S7-1500 system,
e.g. for web server accesses without real-time capability
• Security Integrated
- Stateful Packet Inspection Firewall
- Secure communication via VPN (IPsec)
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 • Protocols for secure communication
UDP - Secure access to the web server of the CPU via
G_IK10_XX_10353
Note:
You can find order information for software for communication
with PC systems in the Industry Mall.
■ Technical specifications
Article number 6GK7543-1AX00-0XE0 Article number 6GK7543-1AX00-0XE0
product type designation CP 1543-1 product type designation CP 1543-1
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-1500 single
• at the 1st interface 10 ... 1 000 Mbit/s width
interfaces width 35 mm
number of interfaces acc. to 1 height 142 mm
Industrial Ethernet depth 129 mm
number of electrical connections net weight 0.35 kg
• at the 1st interface acc. to 1 fastening method
Industrial Ethernet • S7-1500 rail mounting Yes
type of electrical connection product features, product functions,
• at the 1st interface acc. to RJ45 port product components general
Industrial Ethernet number of units
supply voltage, current • per CPU maximum 8
consumption, power loss
• note depending on CPU type
type of voltage of the supply voltage DC
performance data open
supply voltage 1 from backplane bus 15 V communication
relative symmetrical tolerance at DC number of possible connections for
• at 15 V 3% open communication
consumed current • by means of T blocks maximum 118; depending on the system upper
• from backplane bus at DC at 15 V 0.35 A limit
typical data volume
power loss [W] 5.3 W • as user data per ISO on TCP 65 536 byte
ambient conditions connection for open communication
by means of T blocks maximum
ambient temperature
number of Multicast stations 118
• for vertical installation during 0 ... 40 °C
operation performance data S7
communication
• for horizontally arranged busbars 0 ... 60 °C
during operation number of possible connections for
S7 communication
• during storage -40 ... +70 °C
• maximum 118; depending on the system upper
• during transport -40 ... +70 °C limit
relative humidity performance data multi-protocol
• at 25 °C without condensation 95 % mode
during operation maximum number of active connections with 118
protection class IP IP20 multi-protocol mode
■ Technical specifications
Article number 6GK7543-1AX00-0XE0 Article number 6GK7543-1AX00-0XE0
product type designation CP 1543-1 product type designation CP 1543-1
performance data IT functions product functions security
number of possible connections firewall version stateful inspection
• as client by means of FTP maximum 32 product function with VPN connection IPSec
• as server by means of FTP maximum 16 type of encryption algorithms with AES-256, AES-192, AES-128,
number of possible connections VPN connection 3DES-168, DES-56
• as server by means of HTTP
maximum
4 type of authentication procedure with Preshared key (PSK),
VPN connection X.509v3 certificates 4
• as email client maximum 1 type of hashing algorithms with MD5, SHA-1
VPN connection
data volume as user data for email 64 Kibyte
maximum number of possible connections with 16
VPN connection
performance data telecontrol
product function
protocol is supported
• password protection for Web No
• TCP/IP Yes applications
product functions management, • ACL - IP-based No
configuration, engineering
• ACL - IP-based for PLC/routing No
product function MIB support Yes
• switch-off of non-required services Yes
protocol is supported
• blocking of communication via No
• SNMP v1 Yes physical ports
• DCP Yes • log file for unauthorized access Yes
• LLDP No product functions time
configuration software product function SICLOCK support Yes
• required STEP 7 Professional V14 (TIA Portal) product function pass on time Yes
or higher synchronization
identification & maintenance function protocol is supported
• I&M0 - device-specific information Yes • NTP Yes
• I&M1 – higher level Yes standards, specifications, approvals
designation/location designation hazardous environments
product functions diagnostics certificate of suitability CCC for Yes
product function web-based Yes; via S7-1500 CPU hazardous zone according to GB
diagnostics standard
product functions routing
service routing note IP routing up to 1 Mbps
product function
• static IP routing Yes
• static IP routing IPv6 No
• dynamic IP routing No
• dynamic IP routing IPv6 No
protocol is supported
• RIP v1 No
• RIPv2 No
• RIPnG for IPv6 No
• OSPFv2 No
• OSPFv3 for IPv6 No
• VRRP No
• VRRP for IPv6 No
• BGP No
• PPP No
• PPoE via DSL No
■ Overview
All functions are configured using STEP 7 Professional V15.1
update 3 (TIA Portal) or higher.
The CP 1545-1 supports the following communications services:
• PG/OP communication
• S7 communication
• Open user communication (SEND/RECEIVE, FETCH/WRITE)
• IT communication
4 - MQTT Publish for transferring selected data to a cloud
system or MQTT broker
- MQTT Subscribe for receiving data from a cloud system or
MQTT broker
- FTP functions (File Transfer Protocol FTP/FTPS) for file
management and access to data blocks in the CPU
(client and server function)
- Access (read and write modes) to csv files stored on the
memory card of the CPU via FTP(S)
- Sending emails via SMTP or ESMTP with "SMTP-Auth" for
authentication to an email server (also with IPv6)
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 - Static IP routing with up to 1 Mbps via IPv4 to other
UDP CP 1545-1 / CP 1543-1 / CM 1542-1 units in the S7-1500
system, e.g. for web server accesses without real-time
G_IK10_XX_10353
capability
• Security Integrated
- Stateful Packet Inspection Firewall
The SIMATIC CP 1545-1 communications processor securely
connects the SIMATIC S7-1500 Controller to Industrial Ethernet • Protocols for secure communication
networks. The new CloudConnect functionality enables easy - Secure access to the web server of the CPU via the
and reliable transfer of all selected data from the SIMATIC HTTPS protocol
S7-1500 to MindSphere, or a cloud solution that supports the - Secure file transfer using FTPS
standardized MQTT protocol, e.g. Microsoft Azure or IBM Cloud. - Secure time of day transfer (NTP)
The CP protects the SIMATIC S7-1500 station from unauthorized - SNMPv3 for tap-proof transfer of network analysis
access with the integrated SPI (Stateful Packet Inspection) information
firewall. Data from cloud systems or MQTT brokers can also be - Encrypted email communication via SMTPS (Port 587)
received using the MQTT protocol. - Secure open communication over TCP/IP
• Integration of the S7-1500 into IPv6-based networks
The CloudConnect function of the CP 1545-1 is easy to configure
An IPv6-compliant IP address can be used for the following
with a few input screens in TIA Portal. First, all the parameters
communications services:
required for the different cloud platforms are specified. The data
- MQTT
intended for the cloud is then selected from the tag management
- FETCH/WRITE access (CP as server)
of the SIMATIC S7-1500 and saved as topics to be transferred
- FTP server mode
with the corresponding trigger conditions.
- FTP client mode with addressing via program block
- Email transfer with addressing via program block
■ Technical specifications
Article number 6GK7545-1GX00-0XE0 Article number 6GK7545-1GX00-0XE0
product type designation CP 1545-1 product type designation CP 1545-1
supply voltage, current performance data open
consumption, power loss communication
type of voltage of the supply voltage DC number of possible connections for
supply voltage 1 from backplane bus 15 V open communication
relative symmetrical tolerance at DC • by means of T blocks maximum 118; depending on the system
upper limit
• at 15 V
consumed current
3%
data volume
• as user data per ISO on TCP 65 536 byte
4
• from backplane bus at DC at 15 V 0.3 A connection for open communication
typical by means of T blocks maximum
power loss [W] 4.5 W number of Multicast stations 118
ambient conditions performance data S7
ambient temperature communication
• for vertical installation during 0 ... 40 °C number of possible connections for
operation S7 communication
• for horizontally arranged busbars 0 ... 60 °C • maximum 118; depending on the system
during operation upper limit
• during storage -40 ... +70 °C performance data multi-protocol
mode
• during transport -40 ... +70 °C
number of active connections with 118
relative humidity multi-protocol mode
• at 25 °C without condensation 95 % performance data IT functions
during operation maximum
number of possible connections
protection class IP IP20
• as client by means of FTP maximum 32
design, dimensions and weights
• as server by means of FTP maximum 16
module format Compact module S7-1500 single
width number of possible connections
width 35 mm • as server by means of HTTP 4
maximum
height 142 mm
• as email client maximum 1
depth 129 mm
data volume as user data for email 64 Kibyte
net weight 0.32 kg maximum
fastening method performance data telecontrol
• S7-1500 rail mounting Yes protocol is supported
product features, product functions, • TCP/IP Yes
product components general
product functions management,
number of units configuration, engineering
• per CPU maximum 8 product function MIB support Yes
• note depending on CPU type protocol is supported
product functions cloud • SNMP v1 Yes
connectivity
• SNMP v3 Yes
protocol is supported
• DCP Yes
• Message Queuing Telemetry Yes
Transport (MQTT) • LLDP Yes
• Advanced Message Queuing No configuration software
Protocol (AMQP) • required STEP 7 Professional V15.1
product function for cloud (TIA Portal) or higher
connectivity identification & maintenance function
• trigger management Yes • I&M0 - device-specific information Yes
• time stamping Yes • I&M1 – higher level Yes
product feature for cloud connectivity No designation/location designation
buffered message frame memory
number of data points per device 500
maximum
■ Technical specifications
Article number 6GK7545-1GX00-0XE0 Article number 6GK7545-1GX00-0XE0
product type designation CP 1545-1 product type designation CP 1545-1
product functions diagnostics product functions time
product function web-based Yes; via S7-1500 CPU product function SICLOCK support No
diagnostics product function pass on time Yes
product functions routing synchronization
service routing note IP routing up to 1 Mbps protocol is supported
4 product function
• static IP routing Yes
• NTP
standards, specifications, approvals
Yes
■ Overview
• TIM 1531 IRC communications module for telecontrol
applications with four interfaces as a stand-alone device for
SIMATIC S7-1500 for use in wide area networks (WANs)
• For universal use in a station, node station and control center
• Communication either via the SINAUT ST7,
IEC 60870-5-101/104 or DNP3 telecontrol protocols
• Operation via VPN (IPsec/OpenVPN) with additional
SIMATIC NET components
• Wireless communication via mobile wireless routers, 4
modems or radio devices
• Wired communication via Ethernet, Internet, 2/4-wire cables
(SHDSL), dialup modems or dedicated line modem
• Frame buffer for seamless recording of data
• Support of redundant communication paths
• Simple configuration with STEP 7 Professional V15.1
(TIA Portal)
SCALANCE M816-1 ADSL router 6GK5816-1BA00-2AA2 For connecting two TIMs via their
RS232 interfaces without modems
4 For wired IP communication of
Ethernet-based automation devices
(null modem); cable length 6 m
SITOP compact 24 V/0.6 A 6EP1331-5BA00
via Internet Service Providers; VPN,
firewall, NAT; 4-port switch; Single-phase power supply
1x digital input, 1x digital output; with wide range input
ADSL2+, Annex B, J 85 ... 264 V AC/110 ... 300 V DC,
SCALANCE M826-2 SHDSL router 6GK5826-2AB00-2AB2 24 V stabilized output voltage,
0.6 A nominal value of output
For IP communication via the current, slim design
2-wire and 4-wire cables of
Ethernet-based automation SIMATIC PM 1507 24 V/3 A 6EP1332-4BA00
devices; SHDSL topology: Stabilized power supply for
point-to-point, bonding, line bridge SIMATIC S7-1500 input:
mode, routing mode with VPN, 120/230 V AC output: 24 V DC/3 A
firewall, NAT; 4-port switch,
1x digital input, 1x digital output SIMATIC PM 1507 24 V/8 A 6EP1333-4BA00
MD720 modem 6NH9720-3AA01-0XX0 Stabilized power supply for
SIMATIC S7-1500 input:
GSM/GPRS, 2G mobile wireless 120/230 V AC output: 24 V DC/8 A
modem with RS232 interface; for • Output current 3 A
GSM services CSD, GPRS, SMS;
Quadband GSM; AT command • Output current 8 A 6EP1333-4BA00
interface; note country-specific
approvals! Autom. GPRS Note:
connection; including gender
changer for RS232/PPI adapter You will find ordering data for software for communicating with
PC systems in the Industry Mall under System connections –
Software overview
■ Technical specifications
Article number 6GK7543-1MX00-0XE0 Article number 6GK7543-1MX00-0XE0
product type designation TIM 1531 IRC product type designation TIM 1531 IRC
transfer rate supply voltage, current
transfer rate consumption, power loss
• at the 1st interface 10 ... 1 000 Mbit/s type of voltage of the supply voltage DC
• at the 2nd interface 10 ... 100 Mbit/s supply voltage 24 V
• at interface 3 10 ... 100 Mbit/s supply voltage 20.4 ... 28.8 V
• acc. to RS 232 300 ... 115 200 bit/s supply voltage external at DC rated 24 V
value
interfaces
supply voltage external at DC rated 20.4 ... 28.8 V
number of interfaces acc. to 3 value
Industrial Ethernet
consumed current
number of electrical connections
• from external supply voltage 0.15 A
• for external data transmission acc. to 1 at DC at 24 V typical
RS 232
• from external supply voltage 0.3 A
• for power supply 1 at DC at 24 V maximum
number of slots power loss [W] with external supply
• for memory cards 1 voltage at 24 V DC
type of electrical connection • in update mode typical 3.9 W
• of Industrial Ethernet interface RJ45 port • in communication mode typical 3.9 W
type of electrical connection product extension optional backup No
battery
• at interface 1 for external data 9 pin Sub-D-connector,
transmission RS232 switchable to RS485
• for power supply 2-pole plugable terminal block
slot version
• of the memory card SD 1.0, SD 1.1, SDHC, Siemens SMC
storage capacity of the memory 32 Gibyte
card maximum
■ Technical specifications
Article number 6GK7543-1MX00-0XE0 Article number 6GK7543-1MX00-0XE0
product type designation TIM 1531 IRC product type designation TIM 1531 IRC
ambient conditions performance data IT functions
ambient temperature number of possible connections
• during operation 0 ... 70 °C • as server by means of HTTP 2
• for vertical installation during 0 ... 50 °C maximum
operation • as server by means of HTTPS 2; 2 per Ethernet interface
maximum
• for horizontally arranged busbars
during operation
0 ... 70 °C
• as email client maximum 1 4
• during storage -40 ... +70 °C performance data telecontrol
• during transport -40 ... +70 °C suitability for use
relative humidity • node station Yes
• at 25 °C without condensation 95 % • substation Yes
during operation maximum • TIM control center Yes
protection class IP IP20 control center connection Systems with ST7, DNP3 and
design, dimensions and weights IEC 60870-5-101/104 protocol
module format Compact module • by means of a permanent Systems with ST7, DNP3 and
S7-1500 double-wide connection IEC 60870-5-101/104 protocol
width 70 mm protocol is supported
height 147 mm • DNP3 Yes
depth 129 mm • IEC 60870-5 Yes
net weight 0.525 kg • SINAUT ST1 protocol No
fastening method • SINAUT ST7 protocol Yes
• 35 mm top hat DIN rail mounting No • Modbus RTU No
• S7-300 rail mounting No product function data buffering Yes; 100000 data telegrams (ST7) or
• S7-1500 rail mounting Yes if connection is aborted 250000 events (IEC 60870-5 / DNP3)
product features, product functions, number of data points per station 3 000
product components general maximum
product function number of DNP3 masters
• DynDNS client No • for Ethernet maximum 4
number of units • with RS 232 interface maximum 4
• note Number of TIM per S7-1500: 1 product feature buffered message Yes
frame memory
wire length
transmission format
• with RS 232 interface maximum 6m
• for SINAUT ST7 protocol with polling Yes
• with RS 485 interface maximum 30 m or spontaneous 10-bit or 11-bit
performance data S7 operating mode for scanning of data
communication transmission
number of possible connections for • with dedicated line/radio link with Polling, polling with time slot
S7 communication SINAUT ST7 protocol procedure
• maximum 132; only via LAN • with dial-up network with spontaneous
• with PG connections maximum 4 SINAUT ST7 protocol
• with PG/OP connections maximum 4 hamming distance
• with OP connections maximum 4 • for SINAUT ST7 protocol 4
service performance data teleservice
• of SIMATIC communication as Yes diagnostics function online Yes
server diagnostics with SIMATIC STEP 7
• SINAUT ST7 via S7 communication Yes product function
• PG/OP communication Yes • program download with Yes
SIMATIC STEP 7
• remote firmware update Yes
• remote configuration Yes
■ Technical specifications
Article number 6GK7543-1MX00-0XE0 Article number 6GK7543-1MX00-0XE0
product type designation TIM 1531 IRC product type designation TIM 1531 IRC
product functions management, product functions security
configuration, engineering product function
product function MIB support Yes • MSC client via GPRS modem with Yes
protocol is supported MSC capability
• SNMP v1 Yes protocol
4 • SNMP v3
• DCP
Yes
Yes
• is supported MSC protocol
• with Virtual Private Network MSC is
Yes
TCP/IP
• LLDP Yes supported
configuration software key length for MSC with Virtual Private 128 bit
Network
• required STEP 7 Professional V14 SP1
(TIA Portal) or higher number of possible connections
• for CPU configuring required No • as MSC client with VPN connection 1
SINAUT TD7 block library for CPU • as MSC server with VPN connection 127
• for PG configuring required No product functions time
SINAUT ST7 configuration software product function SICLOCK support No
for PG
product function pass on time Yes
storage location of TIM configuration Flash or SD card of the TIM 1531 IRC synchronization
data
protocol is supported
identification & maintenance function
• NTP Yes
• I&M0 - device-specific information Yes
• NTP (secure) Yes
• I&M1 – higher level Yes
designation/location designation product component hardware real No
time clock
• I&M2 - installation date Yes
product feature hardware real time No
• I&M3 - comment Yes clock w. battery backup
product functions diagnostics time synchronization
product function web-based Yes • from NTP-server Yes
diagnostics
• from GPS-signal No
product functions routing
• from control center Yes
service routing note IP routing up to 1 Mbps
• from mobile network provider No
product function
• PC No
• static IP routing Yes
• manual setting No
• static IP routing IPv6 Yes
product functions position
• dynamic IP routing No detection
• dynamic IP routing IPv6 No product function
protocol is supported • position detection with GPS No
• RIP v1 No • pass on position data No
• RIPv2 No standards, specifications, approvals
• RIPnG for IPv6 No hazardous environments
• OSPFv2 No certificate of suitability CCC for Yes
• OSPFv3 for IPv6 No hazardous zone according to GB
standard
• VRRP No
• VRRP for IPv6 No
• BGP No
• PPP No
• PPoE via DSL No
■ Overview
• Access points in SIMATIC S7-1500 design are suitable
for applications where the device is to be mounted in
the control cabinet
■ Technical specifications
Article number 6GK5774-1FX00-0AA0 Article number 6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0 1) 6GK5774-1FX00-0AB0 1)
6GK5774-1FX00-0AC0 2) 6GK5774-1FX00-0AC0 2)
Product type designation W774-1 RJ45 Product type designation W774-1 RJ45
Transfer rate ambient conditions
Transfer rate Ambient temperature
• with WLAN maximum 300 Mbit/s • during operation -20 ... +60 °C
■ Technical specifications
Article number 6GK5774-1FX00-0AA0 Article number 6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0 1) 6GK5774-1FX00-0AB0 1)
6GK5774-1FX00-0AC0 2) 6GK5774-1FX00-0AC0 2)
Product type designation W774-1 RJ45 Product type designation W774-1 RJ45
Product functions management, Product functions VLAN
configuration, engineering Product function
Number of manageable IP addresses 8 • function VLAN with IWLAN Yes
in client
Product function
Product functions DHCP
Product function
4
• CLI Yes
• DHCP client Yes
• web-based management Yes
• DHCP server Yes
• MIB support Yes
• DHCP Option 82 Yes
• TRAPs via email Yes
Product functions redundancy
• configuration with STEP 7 Yes
Protocol is supported
• configuration with STEP 7 Yes
in the TIA Portal • STP/RSTP Yes
• operation with IWLAN controller No • MSTP Yes
• operation with Enterasys WLAN No • RSTP Yes
controller Product functions security
• forced roaming on IP down with Yes Product function
IWLAN
• ACL - MAC-based Yes
• forced roaming on link down with Yes
IWLAN • management security, Yes
ACL-IP based
• WDS Yes
• IEEE 802.1x (radius) Yes
protocol is supported
• NAT/NAPT No
• Address Resolution Protocol (ARP) Yes
• access protection according to Yes
• ICMP Yes IEEE802.11i
• Telnet Yes • WPA/WPA2 Yes
• HTTP Yes • TKIP/AES Yes
• HTTPS Yes protocol is supported
• TFTP Yes • SSH Yes
• DCP Yes • RADIUS Yes
• LLDP Yes Product functions time
Identification & maintenance function Protocol is supported
• I&M0 - device-specific information Yes • NTP Yes
• I&M1 – higher level Yes • SNTP Yes
designation/location designation
• SIMATIC time synchronization Yes
Product functions diagnostics (SIMATIC Time)
Product function
• PROFINET IO diagnosis Yes
• link check No
• connection monitoring IP-Alive No
• localization via Aeroscout Yes
• SysLog Yes
Protocol is supported
• SNMP v1 Yes
• SNMP v2 Yes
• SNMP v3 Yes
1)
Wireless approval in the USA
2)
Wireless approval in the Israel
■ Technical specifications
Article number 6GK5774-1FX00-0AA0 Article number 6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0 1) 6GK5774-1FX00-0AB0 1)
6GK5774-1FX00-0AC0 2) 6GK5774-1FX00-0AC0 2)
Product type designation W774-1 RJ45 Product type designation W774-1 RJ45
Standards, specifications, approvals Wireless approval You will find the current list of
Standard countries at:
http://www.siemens.com/wireless-
• for FM FM 3611: Class I, Division 2, approvals
■ Overview
■ Technical specifications
Article number 6GK5734-1FX00-0AA0 Article number 6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0 1) 6GK5734-1FX00-0AB0 1)
product type designation W734-1 RJ45 product type designation W734-1 RJ45
transfer rate ambient conditions
transfer rate ambient temperature
• with WLAN maximum 300 Mbit/s • during operation -20 ... +60 °C
• for Industrial Ethernet 10 Mbit/s, 100 Mbit/s • during storage -40 ... +85 °C
■ Technical specifications
Article number 6GK5734-1FX00-0AA0 Article number 6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0 1) 6GK5734-1FX00-0AB0 1)
product type designation W734-1 RJ45 product type designation W734-1 RJ45
product functions management, protocol is supported
configuration, engineering • SSH Yes
number of manageable IP addresses 8 • RADIUS Yes
in client
product functions time
product function
• CLI Yes
protocol is supported
• NTP Yes
4
• web-based management Yes
• SNTP Yes
• MIB support Yes
• SIMATIC time synchronization Yes
• TRAPs via email Yes (SIMATIC Time)
• configuration with STEP 7 Yes standards, specifications, approvals
• configuration with STEP 7 Yes standard
in the TIA Portal
• for FM FM 3611: Class I, Division 2,
• WDS No Groups A,B,C,D, T4 / Class 1,
protocol is supported Zone 2, Group IIC, T4
• Address Resolution Protocol (ARP) Yes • for safety from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1
• ICMP Yes certificate of suitability
• Telnet Yes • EC Declaration of Conformity Yes
• HTTP Yes • CE marking Yes
• HTTPS Yes • C-Tick Yes
• TFTP Yes • E1 approval No
• DCP Yes • railway application in accordance No
• LLDP No with EN 50155
identification & maintenance function • NEMA TS2 No
• I&M0 - device-specific information Yes • IEC 61375 No
• I&M1 – higher level Yes • IEC 61850-3 No
designation/location designation • NEMA4X No
product functions diagnostics • Power-over-Ethernet according Yes
product function IEEE802.3at for type 1 and
IEEE802.3af
• PROFINET IO diagnosis Yes
• Power-over-Ethernet according to Yes
• link check No IEEE802.3at for type 2
• connection monitoring IP-Alive No standard for wireless communication
• SysLog Yes • IEEE 802.11a Yes
protocol is supported • IEEE 802.11b Yes
• SNMP v1 Yes • IEEE 802.11e Yes
• SNMP v2 Yes • IEEE 802.11g Yes
• SNMP v3 Yes • IEEE 802.11h Yes
product functions VLAN • IEEE 802.11i Yes
product function • IEEE 802.11n Yes
• function VLAN with IWLAN No wireless approval You will find the current list of
product functions DHCP countries at:
http://www.siemens.com/wireless-
product function approvals
• DHCP client Yes Marine classification association
• DHCP server Yes • American Bureau of Shipping Yes
• DHCP Option 82 Yes Europe Ltd. (ABS)
product functions redundancy • French marine classification Yes
society (BV)
protocol is supported
• DNV GL Yes
• STP/RSTP Yes
• Korean Register of Shipping (KRS) Yes
• MSTP Yes
• Lloyds Register of Shipping (LRS) Yes
• RSTP Yes
• Nippon Kaiji Kyokai (NK) Yes
product functions security
• Polski Rejestr Statkow (PRS) Yes
product function
• Royal Institution of Naval Architects Yes
• ACL - MAC-based Yes
(RINA)
• management security, ACL-IP based Yes
accessories
• IEEE 802.1x (radius) Yes
accessories 24 V DC screw terminal included in
• NAT/NAPT Yes scope of delivery
• access protection according to Yes
IEEE802.11i
• WPA/WPA2 Yes
• TKIP/AES Yes
1)
Wireless approval in the USA
■ Technical specifications
Article number 6AG1540-1AD00-7AA0 6AG1541-1AD00-7AB0 6AG1540-1AB00-7AA0 6AG1541-1AB00-7AB0
Based on 6ES7540-1AD00-0AA0 6ES7541-1AD00-0AB0 6ES7540-1AB00-0AA0 6ES7541-1AB00-0AB0
SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP
RS232 BA RS232 HF RS422/485 BA RS422/485 HF
Ambient conditions
Ambient temperature during
operation
• horizontal installation, min. -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin -40 °C; = Tmin
(incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost); (incl. condensation/frost);
start-up @ -25 °C start-up @ -25 °C start-up @ -25 °C start-up @ -25 °C
• horizontal installation, max. 70 °C 70 °C 70 °C 70 °C
• vertical installation, min. -40 °C; = Tmin; -40 °C; = Tmin; -40 °C; = Tmin; -40 °C; = Tmin;
Startup @ -25 °C Startup @ -25 °C Startup @ -25 °C Startup @ -25 °C
• vertical installation, max. 40 °C 40 °C 40 °C 40 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
■ Technical specifications
Article number 6AG1540-1AD00-7AA0 6AG1541-1AD00-7AB0 6AG1540-1AB00-7AA0 6AG1541-1AB00-7AB0
Based on 6ES7540-1AD00-0AA0 6ES7541-1AD00-0AB0 6ES7540-1AB00-0AA0 6ES7541-1AB00-0AB0
SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP SIPLUS S7-1500 CM PtP
RS232 BA RS232 HF RS422/485 BA RS422/485 HF
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost condensation/frost condensation/frost condensation/frost
max. (no commissioning under (no commissioning under (no commissioning under (no commissioning under
Resistance
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
4
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); permissible); permissible); permissible);
level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil) level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
of Electrical Insulating Compound Class A Class A Class A Class A
for Printed Board Assemblies
according to IPC-CC-830A
SIPLUS CM 1542-5
communication module
(extended temperature range and
medial exposure)
Communication module for 6AG1542-5DX00-7XE0
electrical connection of
SIMATIC S7-1500 to PROFIBUS
as a DP master or DP slave
Front connectors
For 35 mm modules;
including four potential bridges,
cable ties and individual labeling
strips, 40-pin
• Screw terminals 6ES7592-1AM00-0XB0
• Push-in 6ES7592-1BM00-0XB0
For 25 mm modules; 6ES7592-1BM00-0XA0
■ Design
• 40 terminals, arranged in two rows, numbered consecutively
from 1 to 40
• Direct assignment of terminal to LED and labeling simplifies
wiring, commissioning, and troubleshooting
• Holders for four potential bridges for simple and flexible
creation of potential groups;
four units are supplied with the front connector
(optionally available as spare parts in packs of 20)
• Integrated shielding concept for analog modules and
technology modules;
allows space-saving installation without tools and ensures
high ruggedness and EMC stability;
components supplied with analog modules
• Cable ties for mechanical fixing of the cable bundle
and for strain relief;
1 unit supplied with front connector
■ Overview
With two cabling systems, SIMATIC TOP connect ensures
efficient wiring of the input and output module of the
SIMATIC S7-1500 (35 mm unit): Fully modular connection for fast
and clearly arranged connecting to sensors and actuators in the
field, and flexible connection for simple wiring inside the control
cabinet.
With the TIA Selection Tool, you can select suitable system
cabling for the individual I/O modules with a simple mouse click.
Suitable components for the respective I/O module are always
offered. These can be transferred to the order list and then
4
ordered in the Industry Mall.
Further information can be found on the Internet at
http://www.siemens.com/tia-selection-tool
■ Design
Two cabling variants are available for a wide range of control cabinet concepts:
Fully modular connection
The system consists of: Connection errors are thus practically excluded and installation
• Front connector module overhead is significantly reduced. Systematic connection of the
SIMATIC system. The assembly overhead for the connecting
• Connecting cable cables is drastically reduced thanks to the use of pre-assembled
• Terminal modules in the following versions: Basic module, cables sold by the meter.
signal module and function module
6HQVRUV
&RQQHFWDEOHFDEOHV DQGDFWXDWRUV
SUHDVVHPEOHGZLWKDOHQJWK LQWKHILHOG
RIPWRP
Flexible connection
Flexible connection with front connectors is available with 20 In comparison to conventional single wiring, there is a cost
(Pin1 – 20) or 40 wired single cores. saving of 50% for assembly, since the single cores that have
already been checked on the connector are fixed.
These are available in lengths from 2.5 m to 10.0 m.
Thus no complex pre-assembly of up to two times 20 single
The single cores are available in different versions: cores per module is necessary.
• Wire type H05V-K is used for industrial applications
• The UL/CSA-approved core is available for export to North
America
6,0$7,&վ6 :LUHGIURQWFRQQHFWRU
• The halogen-free version is used where low smoke gas (703 IRU','2PRGXOH
density in the event of fire is required, e.g. in building
automation
The blue wires are numbered sequentially and can be routed
RU
direct to each element in the control cabinet. The numbering of IUHHZLUHV
the single cores corresponds to the coding of the front connector
contacts.
SIMATIC TOP connect for S7-1500/ET 200MP, flexible connection
■ Overview
The fully modular connection for connecting to the digital I/O
modules of the SIMATIC S7-1500 or ET 200MP (35 mm design)
consists of modified front connectors, called front connector
modules, pre-assembled connecting cables of various lengths,
and terminal modules. Suitable components can be selected for
the application in question and joined by means of simple
plug-in connections. The terminal modules are used instead of
conventional terminal blocks and act as the interface to the
sensors and actuators.
4
■ Benefits
• Front connector module, connecting cable and terminal • Reduction in wiring errors, clear control cabinet wiring
module are easy to plug in • Byte-by-byte, or four-bye distribution of the signals in the case
• Fast, low-cost wiring of digital signals
• In the case of digital signals, the supply voltage can be • Each component can be replaced individually
connected to the front connector module or the terminal • Use of pre-assembled cables possible
module
■ Design
Front connector module Terminal module
Modified front connectors, called front connector modules, are The system has both digital and analog terminal modules for
available for connecting to the I/O modules (35 mm design). connecting the I/O signals. These are snapped onto the DIN rail.
These are plugged into the I/O module to be wired instead of The terminal modules with basic or signal functionality are
the front connector. The front connector modules are available available in 1-byte or 4-byte versions.
in many different versions for digital I/O modules, analog
I/O modules and for the 24 V, 2-ampère module. The connecting Terminal modules are available for two different connection
cables are plugged into these front connector modules. methods: with push-in or screw-type terminals. The potential can
be fed in at the terminal module or at the front connector module.
Connecting cable If other voltage or power levels are required in the field, the
There are different versions of the connecting cable. terminal module for TPRo or TPOo output signals is used. For the
TPRo terminal module, relays are used for the implementation.
As a pre-assembled 16-pin or 50-pin round cable For the TPOo terminal module, optocouplers are used for the
(shielded or unshielded) it is available in lengths up to 10 m. implementation. This converts the 24 V DC output signal simply
When assembled, there are one or two insulation displacement and reliably to another voltage or power level. If 230 V AC or
connectors (female ribbon connectors) at both ends of the cable. 110 V AC input signals have to be transmitted to the controller in
the field, a terminal module with relay TPRi is available that
The connecting cable connects the front connector module with simply converts the 230/110 V AC signal to 24 V DC. This means
the terminal module. that there is always the same voltage level on the module side.
As a pre-assembled round cable (unshielded) with a 40-pin plug Use with optocouplers for the TPRo relay modules
on the side of the I/O module (64-channel) and a 50-pin plug for
the connection to the terminal module (4-byte version). The If higher switching frequencies of the relay terminal module are
cable connectors are insulation displacement connectors. required for the output signals, the relay can simply be replaced
with an optocoupler (note technical specifications) in order to
increase the switching frequency.
6HQVRUV
&RQQHFWDEOHFDEOHV DQGDFWXDWRUV
SUHDVVHPEOHGZLWKDOHQJWK LQWKHILHOG
RIPWRP
Connecting cables
Connecting cables for 50-pin, 0.14 mm2
SIMATIC S7-1500
Unshielded
Pre-assembled round cable • 0.5 m 6ES7923-5BA50-0CB0
16-pin, 0.14 mm2 • 1.0 m 6ES7923-5BB00-0CB0
• 1.5 m 6ES7923-5BB50-0CB0
Unshielded
• 2.0 m 6ES7923-5BC00-0CB0
• 0.5 m 6ES7923-0BA50-0CB0
• 2.5 m 6ES7923-5BC50-0CB0
• 1.0 m 6ES7923-0BB00-0CB0
• 3.0 m 6ES7923-5BD00-0CB0
• 1.5 m 6ES7923-0BB50-0CB0
• 4.0 m 6ES7923-5BE00-0CB0
• 2.0 m 6ES7923-0BC00-0CB0
• 5.0 m 6ES7923-5BF00-0CB0
• 2.5 m 6ES7923-0BC50-0CB0
• 6.5 m 6ES7923-5BG50-0CB0
• 3.0 m 6ES7923-0BD00-0CB0
• 8.0 m 6ES7923-5BJ00-0CB0
• 4.0 m 6ES7923-0BE00-0CB0
• 10.0 m 6ES7923-5CB00-0CB0
• 5.0 m 6ES7923-0BF00-0CB0
• 6.5 m 6ES7923-0BG50-0CB0 Shielded
• 8.0 m 6ES7923-0BJ00-0CB0 • 1.0 m 6ES7923-5BB00-0DB0
• 10.0 m 6ES7923-0CB00-0CB0 • 2.0 m 6ES7923-5BC00-0DB0
• 2.5 m 6ES7923-5BC50-0DB0
Shielded
• 3.0 m 6ES7923-5BD00-0DB0
• 1.0 m 6ES7923-0BB00-0DB0
• 4.0 m 6ES7923-5BE00-0DB0
• 2.0 m 6ES7923-0BC00-0DB0
• 5.0 m 6ES7923-5BF00-0DB0
• 2.5 m 6ES7923-0BC50-0DB0
• 6.5 m 6ES7923-5BG50-0DB0
• 3.0 m 6ES7923-0BD00-0DB0
• 8.0 m 6ES7923-5BJ00-0DB0
• 4.0 m 6ES7923-0BE00-0DB0
• 10.0 m 6ES7923-5CB00-0DB0
• 5.0 m 6ES7923-0BF00-0DB0
• 6.5 m 6ES7923-0BG50-0DB0 Version 1 x 40-pin to 1 x 50-pin,
• 8.0 m 6ES7923-0BJ00-0DB0 0.14 mm2
• 10.0 m 6ES7923-0CB00-0DB0 Unshielded
Version 4 x 16 to 1 x 50-pin, • 1.0 m 6ES7923-5BB00-0GB0
0.14 mm2 • 2.0 m 6ES7923-5BC00-0GB0
• 2.5 m 6ES7923-5BC50-0GB0
Unshielded
• 3.0 m 6ES7923-5BD00-0GB0
• 0.5 m 6ES7923-5BA50-0EB0
• 1.0 m 6ES7923-5BB00-0EB0
• 1.5 m 6ES7923-5BB50-0EB0
• 2.0 m 6ES7923-5BC00-0EB0
• 2.5 m 6ES7923-5BC50-0EB0
• 3.0 m 6ES7923-5BD00-0EB0
• 4.0 m 6ES7923-5BE00-0EB0
• 5.0 m 6ES7923-5BF00-0EB0
• 6.5 m 6ES7923-5BG50-0EB0
• 8.0 m 6ES7923-5BJ00-0EB0
• 10.0 m 6ES7923-5CB00-0EB0
Terminal modules
Terminal module TP1 Terminal module TPRi
For 1-wire connection, for 16-pin Relay module for 8 outputs
connecting cables (230 V AC), relay as normally
• Push-in terminals without LEDs 6ES7924-0AA20-0AC0 open contact
• Screw-type terminals without LEDs 6ES7924-0AA20-0AA0 • Push-in terminals with LEDs 6ES7924-0BE20-0BC0
• Push-in terminals with LEDs 6ES7924-0AA20-0BC0 • Screw-type terminals with LEDs 6ES7924-0BE20-0BA0
4
• Screw-type terminals with LEDs 6ES7924-0AA20-0BA0 Terminal module TPOo
For 1-wire connection, for 50-pin Optocoupler module for 8 outputs
connecting cables (max. 24 V DC/4 A)
• Push-in terminals without LEDs 6ES7924-2AA20-0AC0 • Push-in terminals with LEDs 6ES7924-0BF20-0BC0
• Screw-type terminals without LEDs 6ES7924-2AA20-0AA0 • Screw-type terminals with LEDs 6ES7924-0BF20-0BA0
• Push-in terminals with LEDs 6ES7924-2AA20-0BC0
Terminal module for digital
• Screw-type terminals with LEDs 6ES7924-2AA20-0BA0 output modules 2 A
• Push-in terminals, sourcing input, 6ES7924-2AK20-0BC0
with LEDs Terminal module TP2
• Screw-type terminals, sourcing 6ES7924-2AK20-0BA0 • Push-in terminals without LEDs 6ES7924-0BB20-0AC0
input, with LEDs • Screw-type terminals without LEDs 6ES7924-0BB20-0AA0
• Push-in terminals, mid-point 6ES7924-2AM20-0BC0 Terminal module for analog
conductor signal, with LEDs modules
• Screw-type terminals, mid-point 6ES7924-2AM20-0BA0
conductor signal, with LEDs Terminal module TPA, 16-pin
• Push-in terminals without LEDs 6ES7924-0CC20-0AC0
Terminal module TP3
• Screw-type terminals without LEDs 6ES7924-0CC20-0AA0
For 3-wire connection, for 16-pin
connecting cables Terminal module TPA, 50-pin
• Push-in terminals without LEDs 6ES7924-0CA20-0AC0 • Push-in terminals without LEDs 6ES7924-2CC20-0AC0
• Screw-type terminals without LEDs 6ES7924-0CA20-0AA0 • Screw-type terminals without LEDs 6ES7924-2CC20-0AA0
• Push-in terminals with LEDs 6ES7924-0CA20-0BC0 Accessories
• Screw-type terminals with LEDs 6ES7924-0CA20-0BA0 Equipment labeling plates for
• Push-in terminals with LEDs and 6ES7924-0CH20-0BC0 terminal modules in S7-1500
one isolating terminal per channel design
• Screw-type terminals with LEDs 6ES7924-0CH20-0BA0
and one isolating terminal per Equipment labeling plates, 3RT1900-1SB20
channel insertable
P. unit = 340 units
• Push-in terminals with LEDs and 6ES7924-0CL20-0BC0
fuse per channel Shield plate for analog terminal
• Screw-type terminals with LEDs 6ES7924-0CL20-0BA0 module
and one fuse per channel P. unit = 4 units (for connection of 6ES7928-1AA20-4AA0
For 3-wire connection, for 50-pin 15-pin connecting cable)
connecting cables P. unit = 4 units (for connection of 6ES7928-1BA20-4AA0
• Push-in terminals without LEDs 6ES7924-2CA20-0AC0 15-pin connecting cable)
• Screw-type terminals without LEDs 6ES7924-2CA20-0AA0
Shield connection clamp
• Push-in terminals with LEDs 6ES7924-2CA20-0BC0
• Screw-type terminals with LEDs 6ES7924-2CA20-0BA0 For shield plate at SIMATIC end, 6ES7590-5BA00-0AA0
P. unit = 10 units
Terminal module TPRo
For shield plate at field end, 6ES7390-5AB00-0AA0
Relay module for 8 outputs, relay as 2 x 2 ... 6 mm
normally open contact
For shield plate at field end, 6ES7390-5BA00-0AA0
• Push-in terminals with LEDs 6ES7924-0BD20-0BC0
3 ... 8 mm
• Screw-type terminals with LEDs 6ES7924-0BD20-0BA0
For shield plate at field end, 6ES7390-5CA00-0AA0
Terminal module TPRi 4 ... 13 mm
Relay module for 8 outputs
(110 V AC), relay as normally
open contact
• Push-in terminals with LEDs 6ES7924-0BG20-0BC0
• Screw-type terminals with LEDs 6ES7924-0BG20-0BA0
4 • 8.0 m
• 10.0 m
6ES7922-5BJ00-0AC0
6ES7922-5CB00-0AC0
Core type H05Z-K, halogen-free
(0.5 mm2 with screw connection)
• 2.5 m 6ES7922-5BC50-0HC0
• 3.2 m 6ES7922-5BD20-0HC0
• 5.0 m 6ES7922-5BF00-0HC0
• 6.5 m 6ES7922-5BG50-0HC0
• 8.0 m 6ES7922-5BJ00-0HC0
• 10.0 m 6ES7922-5CB00-0HC0
Core type UL/CSA-certified
The front connectors with single cores replace (0.5 mm2 with screw connection)
the SIMATIC standard connectors • 3.2 m 6ES7922-5BD20-0UC0
• 5.0 m 6ES7922-5BF00-0UC0
• 6ES7592-1AM00-0XB0 and 6ES7592-1BM00-0XB0
• 6.5 m 6ES7922-5BG50-0UC0
Front connector with single cores for 16 channels (pins 1-20) Core type H05V-K (0.5 mm2 with
screw connection)
Rated operating voltage 24 V DC • 2.5 m 6ES7922-5BC50-0AB0
Permissible continuous current with 1.5 A • 3.2 m 6ES7922-5BD20-0AB0
simultaneous load of all cores, max. • 5.0 m 6ES7922-5BF00-0AB0
Permissible ambient temperature 0 to 60 °C • 6.5 m 6ES7922-5BG50-0AB0
• 8.0 m 6ES7922-5BJ00-0AB0
Core type H05V-K, UL 1007/1569; CSA TR64,
• 10.0 m 6ES7922-5CB00-0AB0
or halogen-free
Core type H05Z-K, halogen-free
Number of single cores 20
(0.5 mm2 with screw connection)
Core cross-section 0.5 mm2; Cu • 2.5 m 6ES7922-5BC50-0HB0
Bundle diameter in mm approx. 15 • 3.2 m 6ES7922-5BD20-0HB0
• 5.0 m 6ES7922-5BF00-0HB0
Wire color Blue, RAL 5010
• 6.5 m 6ES7922-5BG50-0HB0
Designation of cores Numbered from 1 to 20 • 8.0 m 6ES7922-5BJ00-0HB0
(front connector contact = core number) • 10.0 m 6ES7922-5CB00-0HB0
Assembly Screw contacts Core type UL/CSA-certified
(0.5 mm2 with screw connection)
Front connector with single cores for 32 channels (pins 1-40) • 3.2 m 6ES7922-5BD20-0UB0
• 5.0 m 6ES7922-5BF00-0UB0
Rated operating voltage 24 V DC
• 6.5 m 6ES7922-5BG50-0UB0
Permissible continuous current with 1.5 A
simultaneous load of all cores, max.
Permissible ambient temperature 0 to 60 °C
Core type H05V-K, UL 1007/1569; CSA TR64,
or halogen-free
Number of single cores 40
Core cross-section 0.5 mm2; Cu
Bundle diameter in mm approx. 17
Wire color Blue, RAL 5010
Designation of cores Numbered from 1 to 40
(front connector contact = core number)
Assembly Screw contacts
■ Overview
The wiring of the
• SIMATIC S7-1500 IO (25 mm)
• SIMATIC ET 200SP
• SIMATIC S7-1200
• LOGO!
with the sensors/actuators is a significant factor with respect to
time/cost overhead during configuration, control cabinet design,
procurement and ease of servicing. The SIMATIC TOP connect
system cabling makes connection easy, fast and secure.
4
■ Design
The unshielded universal connection cable is offered for • 16-pin ID connector (insulation displacement) for connection
a wide range of control cabinet concepts. to the SIMATIC TOP connect terminal modules for 8 I/Os:
- 3-wire connection using the appropriate terminal module
It comprises: for quick, error-free, wiring
• 16-pin round cable with a core diameter of 0.14 mm2, - Galvanic isolation and adaptation using a coupling relay
pre-assembled with wire end ferrules for connection for easy implementation of potential groups in the system
to the controller: - High output current (up to 4 A), even for higher switching
- labeled with "0" … "7" for the control inputs/outputs frequencies, using an optocoupler module (overload and
- labeled with "M" for mass short-circuit proof)
- labeled with "L+" for 24 V DC potential - Implementation of isolating terminals using switch modules
enabling individual signals to be measured
- Channel-wise protection of I/Os using a fuse module with
a thermal fuse
10 end sleeves
per Universal
connecting Cable IDC connector
SIMATIC S7-1500,
I/O module (25 mm) incl.
front connector module
■ Overview
Important properties:
• 16-channel fail-safe digital input module for
ET 200MP/S7-1500
• For fail-safe reading of sensor information (1 or 2-channels)
• Provides integral discrepancy evaluation for 2-out-of-2 signals
• 4 internal sensor supplies (incl. test function) onboard
• Certified up to SIL 3 (IEC 61508), PL e (ISO 13849)
• LED display for error, operation, supply voltage and status 4
• Clear module labeling
- Plain text identification of the module type
- Complete Article No.
- 2D matrix code (article and serial number)
- Connection diagram
- Hardware and firmware version
• Optional labeling accessories
- Labeling sheets, yellow
Fail-safe digital input module: F-DI 16x24VDC PROFISAFE • The modules support PROFIsafe in both PROFIBUS and
PROFINET configurations. Can be used with all fail-safe
SIMATIC S7-1500 F-CPUs in the central configuration, as well
as ET 200MP distributed I/O with all other SIMATIC S7 F-CPUs.
4 Requirement:
Windows 7 SP1 (64-bit),
Windows 10 Professional/Enterprise
• Monitoring the supply voltage
• Wire-break
Yes
No
(64-bit), • Short-circuit Yes
Windows Server 2008 R2 SP1 • Group error Yes
(64-bit),
Windows Server 2012 R2 (64-bit), Diagnostics indication LED
Windows Server 2016 (64-bit); • RUN LED Yes; green LED
STEP 7 as of V5.5 SP1; • ERROR LED Yes; red LED
Please also consider the operating
systems that have been released • Channel status display Yes; green LED
for the used STEP 7 version • for channel diagnostics Yes; red LED
Floating license for 1 user; software 6ES7833-1FC02-0YA5 • for module diagnostics Yes; red LED
and documentation on DVD; license Potential separation
key on USB flash drive
Potential separation channels
Floating license for 1 user; 6ES7833-1FC02-0YH5
software, documentation and • between the channels and Yes
license key for download1); backplane bus
Email address required for delivery Standards, approvals, certificates
1) For up-to-date information and download availability, see: Suitable for safety functions Yes
http://www.siemens.com/tia-online-software-delivery Highest safety class achievable
in safety mode
■ Technical specifications • Performance level according to
ISO 13849-1
PLe
■ Overview
Important properties:
• 8-channel digital fail-safe output module for
ET 200MP/S7-1500
• Fail-safe 2-channel activation
(parameterizable PM/PP switching) of actuators
• Actuators can be controlled up to 2 A
• Certified up to SIL 3 (IEC 61508), PL e (ISO 13849)
• LED display for error, operation, supply voltage and status
• Clear module labeling
4
- Plain text identification of the module type
- Complete Article No.
- 2D matrix code (article and serial number)
- Connection diagram
- Hardware and firmware version
• Optional labeling accessories
- Labeling sheets, yellow
• The module supports PROFIsafe in both PROFIBUS and
Digital fail-safe digital output module: PROFINET configurations.
F-DQ 8x24VDC 2A PPM PROFISAFE
• Can be used with all fail-safe SIMATIC S7-1500 F-CPUs
in the central configuration, as well as ET 200MP distributed
I/O with all other SIMATIC S7 F-CPUs.
4 Requirement:
Windows 7 SP1 (64-bit),
Windows 10 Professional/Enterprise
(per module)
horizontal installation
(64-bit), - up to 40 °C, max. 16 A
Windows Server 2008 R2 SP1 - up to 60 °C, max. 8A
(64-bit),
Windows Server 2012 R2 (64-bit), vertical installation
Windows Server 2016 (64-bit); - up to 40 °C, max. 8A
STEP 7 as of V5.5 SP1; Interrupts/diagnostics/
Please also consider the operating status information
systems that have been released
for the used STEP 7 version Diagnostics function Yes
Floating license for 1 user; 6ES7833-1FC02-0YA5 Substitute values connectable No
software and documentation on DVD; Alarms
license key on USB flash drive • Diagnostic alarm Yes
Floating license for 1 user; 6ES7833-1FC02-0YH5 Diagnoses
software, documentation and
license key for download1); • Monitoring the supply voltage Yes
Email address required for delivery • Wire-break Yes
1) For up-to-date information and download availability, see: • Short-circuit Yes
http://www.siemens.com/tia-online-software-delivery • Group error Yes
Diagnostics indication LED
■ Technical specifications • RUN LED Yes; green LED
• ERROR LED Yes; red LED
Article number 6ES7526-2BF00-0AB0
• Monitoring of the supply voltage Yes
ET 200MP, F-DQ 8x24VDC 2A PPM (PWR-LED)
General information • Channel status display Yes; green LED
Product type designation F-DQ 8x24VDC/2A PPM • for channel diagnostics Yes; red LED
Engineering with • for module diagnostics Yes; red LED
• STEP 7 TIA Portal configurable/ V13 SP1 with HSP 0086 Potential separation
integrated from version
Potential separation channels
Operating mode
• between the channels and Yes
• DQ Yes backplane bus
Supply voltage Standards, approvals, certificates
Rated value (DC) 24 V Suitable for safety functions Yes
Reverse polarity protection Yes Highest safety class achievable
Digital outputs in safety mode
Number of digital outputs 8 • Performance level according to PLe
ISO 13849-1
Current-sinking Yes
• SIL acc. to IEC 61508 SIL 3
Current-sourcing Yes
Ambient conditions
Short-circuit protection Yes
Ambient temperature during
Open-circuit detection Yes operation
Overload protection Yes • horizontal installation, min. 0 °C
Limitation of inductive shutdown PM-switching: -24 V + (-47 V), • horizontal installation, max. 60 °C
voltage to PP-switching: -24 V
• vertical installation, min. 0 °C
Switching capacity of the outputs
• vertical installation, max. 40 °C
• with resistive load, max. 2A
Dimensions
• on lamp load, max. 10 W
Width 35 mm
Load resistance range
Height 147 mm
• lower limit 12 Ω
Depth 129 mm
• upper limit 2 000 Ω
Weights
Output voltage
Weight, approx. 300 g
• Type of output voltage DC
• for signal "1", min. 24 V; L+ (-0.5 V)
Output current
• for signal "1" rated value 2A
• for signal "0" residual current, max. 0.5 mA; Current-sourcing,
or current sourcing and sinking
switches individually,
current sinking: max. 1 mA
4 Supply voltage
Rated value (DC) 24 V
Reverse polarity protection Yes
Digital outputs
Number of digital outputs 8
Current-sinking Yes
Current-sourcing Yes
Short-circuit protection Yes
Open-circuit detection Yes
Overload protection Yes
SIPLUS digital fail-safe output module:
F-DQ 8x24 V DC 2 A PPM Limitation of inductive shutdown PM-switching: -24 V + (-47 V),
voltage to PP-switching: -24 V
Important properties: Switching capacity of the outputs
• 8-channel digital fail-safe output module for • with resistive load, max. 2A
ET 200MP/S7-1500 • on lamp load, max. 10 W
• Fail-safe 2-channel activation Load resistance range
(parameterizable PM/PP switching) of actuators • lower limit 12 Ω
• Actuators can be controlled up to 2 A • upper limit 2 000 Ω
• Certified up to SIL 3 (IEC 61508), PL e (ISO 13849) Output voltage
• LED display for error, operation, supply voltage and status • Type of output voltage DC
• Clear module labeling • for signal "1", min. 24 V; L+ (-0.5 V)
- Plain text identification of the module type Output current
- Complete Article No. • for signal "1" rated value 2A
- 2D matrix code (article and serial number) • for signal "0" residual current, max. 0.5 mA; Current-sourcing, or current
- Connection diagram sourcing and sinking switches
- Hardware and firmware version individually, current sinking: max. 1 mA
• Optional labeling accessories Switching frequency
- Labeling sheets, yellow • with resistive load, max. 30 Hz
• The module supports PROFIsafe in both PROFIBUS and • with inductive load, max. 0.1 Hz
PROFINET configurations. • on lamp load, max. 10 Hz
• Can be used with all fail-safe SIMATIC S7-1500 F-CPUs Total current of the outputs
in the central configuration, as well as ET 200MP distributed • Current per channel, max. 2A
I/O with all other SIMATIC S7 F-CPUs. Total current of the outputs
(per module)
Note:
horizontal installation
SIPLUS extreme products are based on SIMATIC standard - up to 40 °C, max. 16 A
products. The contents listed here were taken from the - up to 60 °C, max. 8A
respective standard products. SIPLUS extreme-specific
vertical installation
information was added.
- up to 40 °C, max. 8A
■ Technical specifications
Article number 6AG1526-2BF00-2AB0 Article number 6AG1526-2BF00-2AB0
Based on 6ES7526-2BF00-0AB0 Based on 6ES7526-2BF00-0AB0
SIPLUS S7-1500 F-DQ 8x24VDC/2A SIPLUS S7-1500 F-DQ 8x24VDC/2A
Diagnostics indication LED Use on ships/at sea
• RUN LED Yes; green LED - to biologically active substances Yes; Class 6B2 mold and fungal
• ERROR LED Yes; red LED according to EN 60721-3-6 spores (excluding fauna);
Class 6B3 on request
• Monitoring of the supply voltage Yes
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt
(PWR-LED)
• Channel status display Yes; green LED
according to EN 60721-3-6 spray acc. to EN 60068-2-52
(severity degree 3); * 4
• for channel diagnostics Yes; red LED - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
• for module diagnostics Yes; red LED according to EN 60721-3-6
Potential separation Usage in industrial process
technology
Potential separation channels
- Against chemically active Yes; Class 3 (excluding
• between the channels and Yes substances acc. to EN 60654-4 trichlorethylene)
backplane bus
- Environmental conditions for Yes; Level GX group A/B
Standards, approvals, certificates process, measuring and control (excluding trichlorethylene;
Suitable for safety functions Yes systems acc. to ANSI/ISA-71.04 harmful gas concentrations
up to the limits of
Highest safety class achievable in
EN 60721-3-3 class 3C4
safety mode
permissible);
• Performance level according to PLe level LC3 (salt spray) and
ISO 13849-1 level LB3 (oil)
• SIL acc. to IEC 61508 SIL 3 Remark
Ambient conditions - Note regarding classification of * The supplied plug covers must
Ambient temperature during environmental conditions acc. to remain in place over the unused
operation EN 60721, EN 60654-4 and interfaces during operation!
ANSI/ISA-71.04
• horizontal installation, min. -30 °C; = Tmin
(incl. condensation/frost) Conformal coating
• horizontal installation, max. 60 °C; = Tmax • Coatings for printed circuit board Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• vertical installation, min. -30 °C; = Tmin
• Protection against fouling acc. to Yes; Type 1 protection
• vertical installation, max. 40 °C; = Tmax EN 60664-3
Altitude during operation relating • Military testing according to Yes; Discoloration of coating
to sea level MIL-I-46058C, Amendment 7 possible during service life
• Installation altitude above sea level, 2 000 m • Qualification and Performance of Yes; Conformal coating, Class A
max. Electrical Insulating Compound for
• Ambient air temperature-barometric Tmin ... Tmax at Printed Board Assemblies
pressure-altitude 1 140 hPa ... 795 hPa according to IPC-CC-830A
(-1 000 m ... +2 000 m) Dimensions
Relative humidity Width 35 mm
• With condensation, tested in 100 %; RH incl. condensation/frost Height 147 mm
accordance with IEC 60068-2-38, (no commissioning under
max. condensation conditions) Depth 129 mm
Resistance Weights
Coolants and lubricants Weight, approx. 300 g
- Resistant to commercially Yes; Incl. diesel and oil droplets
available coolants and lubricants in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and
according to EN 60721-3-3 dry rot spores (with the exception
of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Technical specifications
Article number 6EP1332-4BA00 6EP1333-4BA00
Product S7-1500 PM1507 S7-1500 PM1507
Power supply, type 24 V/3 A 24 V/8 A
Input
Input 1-phase AC 1-phase AC
• Note Automatic range selection Automatic range selection
supply voltage
• 1 at AC rated value 120 V 120 V
• 2 at AC rated value 230 V 230 V
input voltage
• 1 at AC 85 ... 132 V 85 ... 132 V
• 2 at AC 170 ... 264 V 170 ... 264 V
Wide-range input No No
Overvoltage resistance 2.3 × Vin rated, 1.3 ms 2.3 × Vin rated, 1.3 ms
Mains buffering at Vin = 93/187 V at Vin = 93/187 V
Mains buffering at Iout rated, min. 20 ms; at Vin = 93/187 V 20 ms; at Vin = 93/187 V
Rated line frequency 1 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz
Rated line range 45 ... 65 Hz 45 ... 65 Hz
input current
• at rated input voltage 120 V 1.4 A 3.7 A
• at rated input voltage 230 V 0.8 A 1.7 A
Switch-on current limiting (+25 °C), 23 A 62 A
max.
duration of inrush current limiting
at 25 °C
• maximum 3 ms 3 ms
I²t, max. 1.3 A²·s 12 A²·s
Built-in incoming fuse T 3,15 A/250 V (not accessible) T 6.3 A/250 V (not accessible)
Protection in the mains power input Recommended miniature circuit breaker: Recommended miniature circuit breaker:
(IEC 898) 10 A characteristic B or 6 A characteristic C 16 A characteristic B or 10 A characteristic C
■ Technical specifications
Article number 6EP1332-4BA00 6EP1333-4BA00
Product S7-1500 PM1507 S7-1500 PM1507
Power supply, type 24 V/3 A 24 V/8 A
Output
Output Controlled, isolated DC voltage Controlled, isolated DC voltage
Rated voltage Uout DC 24 V 24 V
■ Technical specifications
Article number 6EP1332-4BA00 6EP1333-4BA00
Product S7-1500 PM1507 S7-1500 PM1507
Power supply, type 24 V/3 A 24 V/8 A
Safety
Primary/secondary isolation Yes Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and Safety extra-low output voltage Uout acc. to EN 60950-1 and
EN 50178 and EN 61131-2 EN 50178 and EN 61131-2
4 Protection class
leakage current
Class I Class I
Power supply
For supplying the backplane
bus of the S7-1500 Controller
24 V DC input voltage, 6ES7505-0KA00-0AB0
power 25 W
24/48/60 V DC input voltage, 6ES7505-0RA00-0AB0
power 60 W
24/48/60 V DC input voltage,
power 60 W, buffering functionality
6ES7505-0RB00-0AB0
4
120/230 V AC input voltage, 6ES7507-0RA00-0AB0
power 60 W
Accessories
SIMATIC S7-1500 DIN rail
Fixed lengths, with grounding
elements
• 160 mm 6ES7590-1AB60-0AA0
• 245 mm 6ES7590-1AC40-0AA0
• 482 mm 6ES7590-1AE80-0AA0
• System power supplies for SIMATIC S7-1500 • 530 mm 6ES7590-1AF30-0AA0
• For conversion of AC or DC line voltages to the operating • 830 mm 6ES7590-1AJ30-0AA0
voltages required for the internal electronics For cutting to length by customer,
without drill holes; grounding
• 25 or 60 W output power elements must be ordered
• Can be used for S7-1500 or ET 200MP separately
• Engineering and configuration via STEP 7 V12 and higher • 2000 mm 6ES7590-1BC00-0AA0
(PS 60W 24/48/60V DC HF: from STEP 7 V14 SP1) PE connection element for 6ES7590-5AA00-0AA0
DIN rail 2000 mm
• In addition with PS 60W 24/48/60V DC HF: Retentive storage
of CPU work memory (data) for all S7-1500 CPUs Spare part, 20 units
Power connector 6ES7590-8AA00-0AA0
With coding element for power
supply module; spare part, 10 units
■ Technical specifications
Article number 6ES7505-0KA00-0AB0 6ES7505-0RA00-0AB0 6ES7505-0RB00-0AB0 6ES7507-0RA00-0AB0
S7-1500, PS 25W 24V DC S7-1500, S7-1500, S7-1500,
PS 60W 24/48/60V DC PS 60W 24/48/60V DC HF PS 60W 120/230V AC/DC
General information
Product type designation PS 25W 24VDC PS 60 W 24/48/60 V DC PS 60 W 24/48/60 V DC HF PS 60 W 120/230 V AC/DC
Engineering with
• STEP 7 TIA Portal configurable/ V12 / V12 V12 / V12 V14 SP1 V12 / V12
integrated from version
• STEP 7 configurable/integrated V5.5 SP3 or higher V5.5 SP3 or higher V5.5 SP3 or higher
from version
Installation type/mounting
Rail mounting Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V / 48 V / 60 V 24 V / 48 V / 60 V 120 V / 230 V
Rated value (AC) 120 V / 230 V
Reverse polarity protection Yes Yes Yes
Short-circuit protection Yes Yes Yes Yes
Line frequency
• Rated value 50 Hz Yes
• permissible range, lower limit 47 Hz
• permissible range, upper limit 63 Hz
Mains buffering
• Mains/voltage failure stored 20 ms 20 ms 20 ms 20 ms
energy time
■ Technical specifications
Article number 6ES7505-0KA00-0AB0 6ES7505-0RA00-0AB0 6ES7505-0RB00-0AB0 6ES7507-0RA00-0AB0
S7-1500, PS 25W 24V DC S7-1500, S7-1500, S7-1500,
PS 60W 24/48/60V DC PS 60W 24/48/60V DC HF PS 60W 120/230V AC/DC
Input current
Rated value at 24 V DC 1.3 A 3A 3A
Rated value at 48 V DC 1.5 A 1.5 A
Rated value at 60 V DC 1.2 A 1.2 A
■ Overview
The design and functionality of the SIMATIC PM 1507
single-phase load power supply (PM = power module)
with automatic range selection of the input voltage makes
it an optimal match to the SIMATIC S7-1500 PLC. It supplies
the S7-1500 system components such as CPU, system power
supply (PS), I/O circuits of the input and output modules and,
if necessary, the sensors and actuators with 24 V DC.
Note:
SIPLUS extreme products are based on Siemens standard 4
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
SIPLUS S7-1500
system power supply
(Extended temperature range and
exposure to media)
For supplying the backplane
bus of the S7-1500 Controller
24 V DC input voltage, 6AG1505-0KA00-7AB0
power 25 W
4 24/48/60 V DC input voltage,
power 60 W
6AG1505-0RA00-7AB0
■ Technical specifications
Article number 6AG1505-0KA00-7AB0 6AG1505-0RA00-7AB0 6AG1507-0RA00-7AB0
Based on 6ES7505-0KA00-0AB0 6ES7505-0RA00-0AB0 6ES7507-0RA00-0AB0
SIPLUS S7-1500 PS 1505 25W 24VDC SIPLUS S7-1500 PS 1505 60W 24VDC SIPLUS S7-1500 PS 1507 60W 230VAC
Ambient conditions
Ambient temperature during
operation
• min. -40 °C; = Tmin (incl. condensation/frost); -40 °C; = Tmin (incl. condensation/frost); -40 °C; = Tmin (incl. condensation/frost);
start-up @ -25 °C start-up @ -25 °C start-up @ -25 °C
• max. 70 °C; = Tmax; for vertical mounting 70 °C; = Tmax; 70 °C; = Tmax;
position Tmax = +40 °C > +60 °C max. power input 30 W; for vertical mounting position
for vertical mounting position Tmax = +40 °C
Tmax = +40 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m 2 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m)
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
■ Technical specifications
Article number 6AG1505-0KA00-7AB0 6AG1505-0RA00-7AB0 6AG1507-0RA00-7AB0
Based on 6ES7505-0KA00-0AB0 6ES7505-0RA00-0AB0 6ES7507-0RA00-0AB0
SIPLUS S7-1500 PS 1505 25W 24VDC SIPLUS S7-1500 PS 1505 60W 24VDC SIPLUS S7-1500 PS 1507 60W 230VAC
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry 4
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
4
SIMATIC HMI TP400 Basic 6AV2143-6DB00-0AA0
Keyless
Touch screen operation;
4" TFT widescreen display,
65 536 colors, PROFINET interface
SIMATIC HMI KTP700 Basic 6AV2123-2GB03-0AX0
Basic Panels (2nd Generation) Key/touch-screen operation;
SIMATIC HMI Basic Panels (2nd Generation) with their fully 7" TFT display, 65 536 colors,
PROFINET interface
developed HMI basic functions are the ideal entry-level series
for simple HMI applications. SIMATIC HMI KTP700 Basic DP 6AV2123-2GA03-0AX0
Key/touch-screen operation;
The device family offers panels with 4", 7", 9" and 12" displays, 7" TFT display, 65 536 colors,
as well as combined key and touch operation. PROFIBUS interface
The innovative high-resolution widescreen displays with SIMATIC HMI TP700 Basic 6AV2143-6GB00-0AA0
Keyless
64 000 colors are also suitable for upright installation,
and they can be dimmed down to 100%. The innovative operator Touch screen operation;
interface with improved usability opens up a diverse range of 7" TFT display, 65 536 colors,
options thanks to new controls and graphics. The new USB PROFINET interface
interface enables the connection of keyboard, mouse or SIMATIC HMI KTP900 Basic 6AV2123-2JB03-0AX0
barcode scanner, and supports the simple archiving of data on Key/touch-screen operation;
a USB flash drive as well as the manual backup and restoring of 9" TFT display, 65 536 colors,
the complete panel. PROFINET interface
SIMATIC HMI TP900 Basic 6AV2143-6JB00-0AA0
The integrated Ethernet or RS 485/422 interface (version-specific) Keyless
enables simple connection to the controller.
Touch screen operation;
http://www.siemens.com/basic-panels 9" TFT display, 65 536 colors,
PROFINET interface
SIMATIC HMI KTP1200 Basic 6AV2123-2MB03-0AX0
Key/touch-screen operation;
12" TFT display, 65 536 colors,
PROFINET interface
SIMATIC HMI KTP1200 Basic DP 6AV2123-2MA03-0AX0
Key/touch-screen operation;
12" TFT display, 65 536 colors,
PROFIBUS interface
Starter kits
Starter kit LOGO! + KP300 Basic 6AV2132-0HA00-0AA1
mono PN
Starter kit LOGO! + KTP400 Basic 6AV2132-0KA00-0AA1
Starter kit LOGO! + KTP700 Basic 6AV2132-3GB00-0AA1
Starter kits with a LOGO! consist of:
• the respective SIMATIC HMI Basic
Panel
SIMATIC HMI KP300 Basic
mono PN
SIMATIC HMI KTP400 Basic
SIMATIC HMI KTP700 Basic
• LOGO! 12/24 RCE
• LOGO! POWER 24 V 1.3 A
• LOGO! SOFT COMFORT V7
• WINCC BASIC (TIA Portal)
• Ethernet CAT5 cable, 2 m
Documentation
Additional information on the http://support.automation.
manual for the Basic Panels is siemens.com
available on the Internet at:
Accessories See catalog ST 80 / ST PC or
Industry Mall
■ Overview
SIMATIC HMI Unified Comfort Panels - standard devices
The SIMATIC HMI Unified Comfort Panels consist of six different
devices with varying display sizes.
All devices come with the same number of hardware interfaces
and the same functionality – just select the perfect device for
your needs based on the screen size.
Each Unified Comfort Panel is available in the standard design
with Siemens and SIMATIC HMI branding and a silver-colored
aluminum frame. 4
All Unified Comfort Panels come with integrated Edge functionality.
Siemens Industrial Edge can be used in two different ways:
• Device-managed Edge
• Centrally-managed Edge (planned)
SIMATIC HMI Unified Comfort Panels can also be ordered with
a neutral design. Starter kits are available for standard design
SIMATIC HMI MTP2200 Unified Comfort Panel Standard design front view
devices.
Note:
The technical specifications of the neutral design devices
correspond to the technical specifications of the devices with
standard design.
4 Touch-screen operation;
7" widescreen display
SIMATIC HMI TP900 Comfort 6AV2124-0JC01-0AX0
Touch-screen operation;
9" widescreen display
SIMATIC HMI TP1200 Comfort 6AV2124-0MC01-0AX0
Touch-screen operation;
12" widescreen display
SIMATIC HMI TP1500 Comfort 6AV2124-0QC02-0AX1
Touch-screen operation;
15" widescreen display
SIMATIC HMI Comfort Panels - Standard devices SIMATIC HMI TP1900 Comfort 6AV2124-0UC02-0AX1
• Excellent HMI functionality for demanding applications Touch-screen operation;
19" widescreen display
• Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and
22" diagonals (all 16 million colors) with up to 40% more SIMATIC HMI TP2200 Comfort 6AV2124-0XC02-0AX1
visualization area as compared to the predecessor devices Touch-screen operation;
22" widescreen display
• Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player and Key devices
Web Server SIMATIC HMI KP400 Comfort 6AV2124-1DC01-0AX0
• Dimmable displays from 0 to 100% via PROFIenergy, via the Key operation;
4" widescreen display
HMI project or via a controller
SIMATIC HMI KP700 Comfort 6AV2124-1GC01-0AX0
• Modern industrial design, cast aluminum fronts for 7" upwards
Key operation;
• Upright installation for all touch devices 7" widescreen display
• Data security in the event of a power failure for the device and SIMATIC HMI KP900 Comfort 6AV2124-1JC01-0AX0
for the SIMATIC HMI memory card Key operation;
9" widescreen display
• Innovative service and commissioning concept
SIMATIC HMI KP1200 Comfort 6AV2124-1MC01-0AX0
• Maximum performance with short screen refresh times
Key operation;
• Suitable for extremely harsh industrial environments thanks to 12" widescreen display
extended approvals such as ATEX 2/22 and marine approvals
SIMATIC HMI KP1500 Comfort 6AV2124-1QC02-0AX1
• All versions can be used as an OPC UA client or as a server Key operation;
• Key-operated devices with LED in every function key and new 15" widescreen display
text input mechanism, similar to the keypads of mobile phones Accessories See catalog ST 80 / ST PC or
Industry Mall
• All keys have a service life of 2 million operations
• Configuring with the WinCC engineering software of the
TIA Portal engineering framework
Note:
A 7" and a 15" Comfort Outdoor version are available.
These devices have been specially designed for outdoor
applications in difficult environments. Best display quality,
even under sunlight, UV-resistant fronts and much more.
For more information, please go to:
http://www.siemens.com/comfort-panels
■ Technical specifications
Article number 6AG1123-2DB03-2AX0 6AG1123-2GB03-2AX0 6AG1123-2GA03-2AX0
Based on 6AV2123-2DB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2GA03-0AX0
SIPLUS HMI KTP400 BASIC SIPLUS HMI KTP700 BASIC SIPLUS HMI KTP700 BASIC DP
Ambient conditions
Suited for indoor use Yes Yes
Suited for outdoor use No No
Ambient temperature during
operation
• Operation (vertical installation)
- For vertical installation, min. -20 °C; = Tmin -20 °C -20 °C; = Tmin
- For vertical installation, max. 60 °C; = Tmax 50 °C 50 °C
Altitude during operation relating to
sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning when condensation
max. condensation conditions) condensation conditions) present), vertical mounting position
■ Technical specifications
Article number 6AG1123-2DB03-2AX0 6AG1123-2GB03-2AX0 6AG1123-2GA03-2AX0
Based on 6AV2123-2DB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2GA03-0AX0
SIPLUS HMI KTP400 BASIC SIPLUS HMI KTP700 BASIC SIPLUS HMI KTP700 BASIC DP
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
■ Technical specifications
Article number 6AG1123-2JB03-2AX0 6AG1123-2MB03-2AX0 6AG1123-2MA03-2AX0
Based on 6AV2123-2JB03-0AX0 6AV2123-2MB03-0AX0 6AV2123-2MA03-0AX0
SIPLUS HMI KTP900 BASIC SIPLUS HMI KTP1200 BASIC SIPLUS HMI KTP1200 BASIC DP
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // 4
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning in bedewed state), (no commissioning when condensation
max. condensation conditions) horizontal installation present), vertical mounting position
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1647-0AH11-2AX0 6AG1647-0AA11-2AX0
Based on 6AV6647-0AH11-3AX0 6AV6647-0AA11-3AX0
SIPLUS HMI KP300 BASIC MONO PN 3,6" SIPLUS KTP400 BASIC MONO PN 3,8"
Ambient conditions
Suited for indoor use Yes Yes
Suited for outdoor use No No
Ambient temperature during
operation
• Operation (vertical installation)
- For vertical installation, min. -25 °C -10 °C
- For vertical installation, max. 60 °C 60 °C
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost (no commissioning 100 %; RH incl. condensation/frost (no commissioning
accordance with IEC 60068-2-38, under condensation conditions) under condensation conditions)
max.
■ Technical specifications
Article number 6AG1647-0AH11-2AX0 6AG1647-0AA11-2AX0
Based on 6AV6647-0AH11-3AX0 6AV6647-0AA11-3AX0
SIPLUS HMI KP300 BASIC MONO PN 3,6" SIPLUS KTP400 BASIC MONO PN 3,8"
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores 4
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of
systems acc. to ANSI/ISA-71.04 EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers must remain in place over * The supplied plug covers must remain in place over
environmental conditions acc. to the unused interfaces during operation! the unused interfaces during operation!
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Overview
• Data security in the event of a power failure for the device and
for the SIMATIC HMI memory card
• Innovative service and commissioning concept through
second SD card (automatic backup)
• Easy project transfer via standard cable (standard Ethernet
cable, standard USB cable)
• Maximum performance with short screen refresh times
■ Technical specifications
Article number 6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0
Based on 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIPLUS HMI KTP400 SIPLUS HMI TP700 SIPLUS HMI TP900 SIPLUS HMI TP1200
COMFORT COMFORT COMFORT COMFORT
Ambient conditions
Suited for indoor use Yes Yes Yes Yes
Suited for outdoor use No No No No
Ambient temperature during
operation 4
• Operation (vertical installation)
- For vertical installation, min. 0 °C; = Tmin 0 °C; = Tmin 0 °C; = Tmin 0 °C; = Tmin
- For vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. 100 %; RH incl. 100 %; RH incl. 100 %; RH incl.
accordance with IEC 60068-2-38, condensation/frost (no condensation/frost (no condensation/frost (no condensation/frost (no
max. commissioning under commissioning under commissioning under commissioning under
condensation conditions) condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil Yes; Incl. diesel and oil
available coolants and lubricants droplets in the air droplets in the air droplets in the air droplets in the air
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores fungus and dry rot spores
(with the exception of fauna); (with the exception of fauna); (with the exception of fauna); (with the exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding Yes; Class 3 (excluding
substances acc. to EN 60654-4 trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4 EN 60721-3-3 class 3C4
permissible); permissible); permissible); permissible);
level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil) level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
environmental conditions acc. to must remain in place over must remain in place over must remain in place over must remain in place over
EN 60721, EN 60654-4 and the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
ANSI/ISA-71.04 operation! operation! operation! operation!
■ Technical specifications
Article number 6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0
Based on 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIPLUS HMI KTP400 SIPLUS HMI TP700 SIPLUS HMI TP900 SIPLUS HMI TP1200
COMFORT COMFORT COMFORT COMFORT
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
4 EN 60664-3
• Military testing according to Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating Yes; Discoloration of coating
MIL-I-46058C, Amendment 7 possible during service life possible during service life possible during service life possible during service life
• Qualification and Performance of Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating, Yes; Conformal coating,
Electrical Insulating Compound for Class A Class A Class A Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1124-1DC01- 6AG1124-1GC01- 6AG1124-1JC01- 6AG1124-1MC01- 6AG1124-1QC02-
4AX0 4AX0 4AX0 4AX0 4AX1
Based on 6AV2124-1DC01- 6AV2124-1GC01- 6AV2124-1JC01-0AX0 6AV2124-1MC01- 6AV2124-1QC02-
0AX0 0AX0 0AX0 0AX1
SIPLUS HMI KP400 SIPLUS HMI KP700 SIPLUS HMI KP900 SIPLUS HMI KP1200 SIPLUS HMI KP1500
COMFORT COMFORT COMFORT COMFORT Comfort
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold
according to EN 60721-3-6 and fungal spores
(excluding fauna);
Class 6B3 on request
and fungal spores
(excluding fauna);
Class 6B3 on request
and fungal spores
(excluding fauna);
Class 6B3 on request
and fungal spores
(excluding fauna);
Class 6B3 on request
and fungal spores
(excluding fauna);
Class 6B3 on request
4
- to chemically active substances Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3
according to EN 60721-3-6 (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt (RH < 75 %) incl. salt
spray acc. to spray acc. to spray acc. to spray acc. to spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl.
according to EN 60721-3-6 sand, dust; * sand, dust; * sand, dust; * sand, dust; * sand, dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding (excluding (excluding (excluding (excluding
trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group Yes; Level GX group
process, measuring and control A/B (excluding A/B (excluding A/B (excluding A/B (excluding A/B (excluding
systems acc. to ANSI/ISA-71.04 trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene;
harmful gas harmful gas harmful gas harmful gas harmful gas
concentrations concentrations concentrations concentrations concentrations
up to the limits of up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class EN 60721-3-3 class
3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible); 3C4 permissible);
level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray)
and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil)
Remark
- Note regarding classification of * The supplied plug * The supplied plug * The supplied plug * The supplied plug * The supplied plug
environmental conditions acc. to covers must remain in covers must remain in covers must remain in covers must remain in covers must remain in
EN 60721, EN 60654-4 and place over the unused place over the unused place over the unused place over the unused place over the unused
ANSI/ISA-71.04 interfaces during interfaces during interfaces during interfaces during interfaces during
operation! operation! operation! operation! operation!
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high Yes; Class 2 for high
assemblies acc. to EN 61086 reliability reliability reliability reliability reliability
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of Yes; Discoloration of
MIL-I-46058C, Amendment 7 coating possible coating possible coating possible coating possible coating possible
during service life during service life during service life during service life during service life
• Qualification and Performance of Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal Yes; Conformal
Electrical Insulating Compound for coating, Class A coating, Class A coating, Class A coating, Class A coating, Class A
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1124-0QC02-4AX1 6AG1124-0UC02-4AX1 6AG1124-0XC02-4AX1
Based on 6AV2124-0QC02-0AX1 6AV2124-0UC02-0AX1 6AV2124-0XC02-0AX1
SIPLUS HMI TP1500 Comfort SIPLUS HMI TP1900 Comfort SIPLUS HMI TP2200 Comfort
Altitude during operation relating
to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
4 pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
1 080 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax - 20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
accordance with IEC 60068-2-38, (no commissioning under (no commissioning under (no commissioning under
max. condensation conditions) condensation conditions) condensation conditions)
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt Yes; Class 3C4 (RH < 75 %) incl. salt
according to EN 60721-3-3 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification of * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
environmental conditions acc. to remain in place over the unused remain in place over the unused remain in place over the unused
EN 60721, EN 60654-4 and interfaces during operation! interfaces during operation! interfaces during operation!
ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible Yes; Discoloration of coating possible Yes; Discoloration of coating possible
MIL-I-46058C, Amendment 7 during service life during service life during service life
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Overview
Front doors Shielding
Notes
Siemens ST 70 · 2021
© Siemens 2021
Siemens ST 70 · 2021
© Siemens 2021
■ Technical specifications
General technical specifications SIPLUS S7-300
Ambient temperature range -40/-25 ... +60/70 °C
Conformal coating Coating of the printed circuit boards
and the electronic components
Technical data The technical data of the standard
product applies except for the
environmental conditions.
Ambient conditions
Extended range of environmental
conditions
• with reference to ambient Tmin ... Tmax at
• The entry level CPU in Totally Integrated Automation (TIA) • The CPU with medium to large program memory and quantity
• For smaller applications with moderate processing structures for optional use of SIMATIC engineering tools
performance requirements • High processing power in binary and floating-point arithmetic
SIMATIC Micro Memory Card required for operation of CPU. • Used as central controller in production lines with central and
distributed I/O
■ Overview CPU 314 • PROFIBUS DP master/slave interface
• For comprehensive I/O expansion
• For configuring distributed I/O structures
• Isochronous mode on PROFIBUS
SIMATIC Micro Memory Card required for operation of CPU.
• The CPU with mid-range program memory and quantity • The CPU with a large program memory and quantity
frameworks framework for demanding applications
• High processing power in binary and floating-point arithmetic • For cross-industry automation tasks in series machine, special
• Used as central controller in production lines with central and machine and plant construction
distributed I/O • Used as central controller in production lines with central and
• PROFINET interface with 2-port switch distributed I/O
• PROFINET IO controller for operating distributed I/O on • High processing power in binary and floating-point arithmetic
PROFINET • 2 PROFIBUS DP master/slave interfaces
• PROFINET I-Device for connecting the CPU as an intelligent • For comprehensive I/O expansion
PROFINET device under a SIMATIC or non-Siemens • For configuring distributed I/O structures
PROFINET IO controller
• Isochronous mode on PROFIBUS
• Component-based Automation (CBA) on PROFINET
• Optionally supports the use of SIMATIC engineering tools
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component-based Automation (CBA) SIMATIC Micro Memory Card required for operation of CPU.
• Integrated web server with the option of creating user-defined
web pages
• Combined MPI/PROFIBUS DP master/slave interface
• Isochronous mode on PROFIBUS and PROFINET
SIMATIC Micro Memory Card required for operation of CPU.
• The CPU with a large program memory and quantity • The CPU with high command processing performance, large
framework for demanding applications program memory and quantity framework for demanding
• For cross-industry automation tasks in series machine, special applications
machine and plant construction • For cross-industry automation tasks in series machine, special
• Used as central controller in production lines with central and machine and plant construction
distributed I/O • Used as central controller in production lines with central and
• High processing power in binary and floating-point arithmetic distributed I/O on PROFIBUS and PROFINET
• PROFINET interface with 2-port switch • PROFINET I/O controller for operating distributed I/O on
PROFINET
• PROFINET I/O Controller for operating distributed I/O
on PROFINET • PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
• PROFINET I-Device for connecting the CPU as intelligent PROFINET I/O controller
PROFINET device under a SIMATIC or third-party
PROFINET I/O Controller • PROFINET interface with 2-port switch
• Distributed intelligence in Component Based Automation • Isochronous mode on PROFIBUS or PROFINET
(CBA) on PROFINET • Integrated web server with the option of creating user-defined
• PROFINET proxy for intelligent devices on PROFIBUS DP web pages
in Component Based Automation (CBA) • Distributed intelligence in Component Based Automation
• Integrated web server with the option of creating user-defined (CBA) on PROFINET
web pages • PROFINET proxy for intelligent devices on PROFIBUS DP
• Combined MPI/PROFIBUS DP master/slave interface in Component Based Automation (CBA)
• Isochronous mode on PROFIBUS and PROFINET • Optionally supports the use of SIMATIC engineering tools
• Optionally supports the use of SIMATIC engineering tools SIMATIC Micro Memory Card required for operation of the CPU.
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
Article number 6ES7312-1AE14-0AB0 6ES7314-1AG14-0AB0 6ES7315-2AH14-0AB0 6ES7315-2EH14-0AB0
CPU312, 32KB CPU314, 128 KB CPU315-2DP, 256 KB CPU315-2 PN/DP, 384 KB
General information
Product function
• Isochronous mode Yes Yes; Via PROFIBUS DP or
PROFINET interface
Engineering with
• Programming package STEP 7 V5.5 + SP1 or higher STEP 7 V5.5 + SP1 or higher STEP 7 V5.5 + SP1 or higher STEP 7 V5.5 or higher
or STEP 7 V5.2 + SP1 or or STEP 7 V5.2 + SP1 or or STEP 7 V5.2 + SP1 or
higher with HSP 218 higher with HSP 218 higher with HSP 218
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
Memory
Work memory
• integrated 32 kbyte 128 kbyte 256 kbyte 384 kbyte
• expandable No No No No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.1 µs 0.06 µs 0.05 µs 0.05 µs
for word operations, typ. 0.24 µs 0.12 µs 0.09 µs 0.09 µs
for fixed point arithmetic, typ. 0.32 µs 0.16 µs 0.12 µs 0.12 µs
for floating point arithmetic, typ. 1.1 µs 0.59 µs 0.45 µs 0.45 µs
■ Technical specifications
Article number 6ES7312-1AE14-0AB0 6ES7314-1AG14-0AB0 6ES7315-2AH14-0AB0 6ES7315-2EH14-0AB0
CPU312, 32KB CPU314, 128 KB CPU315-2DP, 256 KB CPU315-2 PN/DP, 384 KB
Counters, timers and their
retentivity
S7 counter
• Number 256 256 256 256
IEC counter
• present Yes Yes Yes Yes
S7 times
• Number 256 256 256 256
5
IEC timer
• present Yes Yes Yes Yes
Data areas and their retentivity
Flag
• Size, max. 256 byte 256 byte 2 048 byte 2 048 byte
Address area
I/O address area
• Inputs 1 024 byte 1 024 byte 2 048 byte 2 048 byte
• Outputs 1 024 byte 1 024 byte 2 048 byte 2 048 byte
Process image
• Inputs, adjustable 1 024 byte 1 024 byte 2 048 byte 2 048 byte
• Outputs, adjustable 1 024 byte 1 024 byte 2 048 byte 2 048 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
• Software clock Yes
Operating hours counter
• Number 1 1 1 1
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes Yes
Protocols
• MPI Yes Yes Yes Yes
• PROFIBUS DP master No No No Yes
• PROFIBUS DP slave No No No Yes
• Point-to-point connection No No No No
PROFIBUS DP master
• Number of DP slaves, max. 124
2. Interface
Interface type Integrated RS 485 interface
Interface types
• RJ 45 (Ethernet) Yes
• RS 485 Yes
• Number of ports 2
Protocols
• MPI No No
• PROFINET IO Controller Yes; Also simultaneously with
IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously with
IO Controller functionality
• PROFINET CBA Yes
• PROFIBUS DP master Yes No
• PROFIBUS DP slave Yes No
PROFIBUS DP master
• Number of DP slaves, max. 124; Per station
■ Technical specifications
Article number 6ES7312-1AE14-0AB0 6ES7314-1AG14-0AB0 6ES7315-2AH14-0AB0 6ES7315-2EH14-0AB0
CPU312, 32KB CPU314, 128 KB CPU315-2DP, 256 KB CPU315-2 PN/DP, 384 KB
PROFINET IO Controller
Services
- Number of connectable 128
IO Devices, max.
- Of which IO devices with IRT, max. 64
- Number of IO Devices with IRT and 128
the option "high flexibility"
- Number of connectable 128
IO Devices for RT, max.
Protocols
Open IE communication
5
• TCP/IP Yes; via integrated
PROFINET interface and
loadable FBs
- Number of connections, max. 8
• ISO-on-TCP (RFC1006) Yes; via integrated
PROFINET interface and
loadable FBs
- Number of connections, max. 8
• UDP Yes; via integrated
PROFINET interface and
loadable FBs
- Number of connections, max. 8
Web server
• supported Yes
Communication functions
PG/OP communication Yes Yes Yes Yes
Data record routing No No Yes Yes
Global data communication
• supported Yes Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes Yes
S7 communication
• supported Yes Yes Yes Yes
S5 compatible communication
• supported Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC
Number of connections
• overall 6 12 16 16
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
- LAD Yes Yes Yes Yes
- FBD Yes Yes Yes Yes
- STL Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes Yes
- HiGraph® Yes Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm 130 mm
Weights
Weight, approx. 270 g 280 g 290 g 340 g
■ Technical specifications
Article number 6ES7317-2AK14-0AB0 6ES7317-2EK14-0AB0 6ES7318-3EL01-0AB0
CPU317-2 DP, 1 MB CPU317-2 PN/DP, 1 MB CPU319-3 PN/DP, 2 MB
General information
Product function
• Isochronous mode Yes; Via PROFIBUS DP or PROFINET Yes; Via 2nd PROFIBUS DP or PROF-
interface INET interface
Engineering with
• Programming package STEP 7 as of V5.5 + SP1 or STEP 7 STEP 7 V5.5 or higher STEP 7 V5.5 or higher
V5.2 + SP1 or higher with HSP 202
Supply voltage
Rated value (DC) 24 V 24 V 24 V
5 Memory
Work memory
• integrated 1 024 kbyte 1 024 kbyte 2 048 kbyte
• expandable No No No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.025 µs 0.025 µs 0.004 µs
for word operations, typ. 0.03 µs 0.03 µs 0.01 µs
for fixed point arithmetic, typ. 0.04 µs 0.04 µs 0.01 µs
for floating point arithmetic, typ. 0.16 µs 0.16 µs 0.04 µs
Counters, timers and their
retentivity
S7 counter
• Number 512 512 2 048
IEC counter
• present Yes Yes Yes
S7 times
• Number 512 512 2 048
IEC timer
• present Yes Yes Yes
Data areas and their retentivity
Flag
• Size, max. 4 096 byte 4 096 byte 8 192 byte
Address area
I/O address area
• Inputs 8 192 byte 8 192 byte 8 192 byte
• Outputs 8 192 byte 8 192 byte 8 192 byte
Process image
• Inputs, adjustable 8 192 byte 8 192 byte 8 192 byte
• Outputs, adjustable 8 192 byte 8 192 byte 8 192 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Operating hours counter
• Number 4 4 4
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes
Protocols
• MPI Yes Yes Yes
• PROFIBUS DP master Yes Yes Yes
• PROFIBUS DP slave Yes; A DP slave at both interfaces Yes Yes; A DP slave at both interfaces
simultaneously is not possible simultaneously is not possible
• Point-to-point connection No No No
PROFIBUS DP master
• Number of DP slaves, max. 124 124 124
■ Technical specifications
Article number 6ES7317-2AK14-0AB0 6ES7317-2EK14-0AB0 6ES7318-3EL01-0AB0
CPU317-2 DP, 1 MB CPU317-2 PN/DP, 1 MB CPU319-3 PN/DP, 2 MB
2. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RJ 45 (Ethernet) Yes
• RS 485 Yes Yes
• Number of ports 2
Protocols
• MPI No No No
• PROFINET IO Controller Yes; Also simultaneously
with IO-Device functionality
No
5
• PROFINET IO Device Yes; Also simultaneously No
with IO Controller functionality
• PROFINET CBA Yes No
• PROFIBUS DP master Yes No Yes
• PROFIBUS DP slave Yes; A DP slave at both interfaces No Yes; A DP slave at both interfaces
simultaneously is not possible simultaneously is not possible
PROFIBUS DP master
• Number of DP slaves, max. 124 124
PROFINET IO Controller
Services
- Number of connectable 128
IO Devices, max.
- Of which IO devices with IRT, max. 64
- Number of IO Devices with IRT and 128
the option "high flexibility"
- Number of connectable 128
IO Devices for RT, max.
3. Interface
Interface types
• RJ 45 (Ethernet) Yes
• Number of ports 2
Protocols
• MPI No
• PROFINET IO Controller Yes; Also simultaneously
with I-Device functionality
• PROFINET IO Device Yes; Also simultaneously
with IO Controller functionality
• PROFINET CBA Yes
• PROFIBUS DP master No
• PROFIBUS DP slave No
PROFINET IO Controller
Services
- Number of connectable 256
IO Devices, max.
- Of which IO devices with IRT, max. 64
- Number of IO Devices with IRT and 256
the option "high flexibility"
- Number of connectable 256
IO Devices for RT, max.
Protocols
Open IE communication
• TCP/IP Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs
- Number of connections, max. 16 32
• ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs
- Number of connections, max. 16 32
• UDP Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs
- Number of connections, max. 16 32
Web server
• supported Yes Yes
■ Technical specifications
Article number 6ES7317-2AK14-0AB0 6ES7317-2EK14-0AB0 6ES7318-3EL01-0AB0
CPU317-2 DP, 1 MB CPU317-2 PN/DP, 1 MB CPU319-3 PN/DP, 2 MB
Communication functions
PG/OP communication Yes Yes Yes
Data record routing Yes Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
5 • supported
S5 compatible communication
Yes Yes Yes
• supported Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC
Number of connections
• overall 32 32 32
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 40 mm 40 mm 120 mm
Height 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm
Weights
Weight, approx. 360 g 340 g 1 250 g
• For plants with medium requirements on the program scope • The CPU with medium to large program memory and quantity
• High processing performance in binary and floating-point structures for optional use of SIMATIC engineering tools
arithmetic • High processing performance in binary and floating-point
arithmetic
SIMATIC Micro Memory Card required for operation of CPU.
• PROFIBUS DP master/slave interface
Note:
• For comprehensive I/O expansion
SIPLUS extreme products are based on SIMATIC standard • For configuring distributed I/O structures
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific SIMATIC Micro Memory Card required for operation of CPU.
information was added. Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Overview SIPLUS CPU 315-2 PN/DP ■ Overview SIPLUS CPU 317-2 PN/DP
• The CPU with medium-sized program memory and quantity • The CPU with a large program memory and quantity
frameworks framework for demanding applications
• High processing performance in binary and floating-point • Distributed intelligence in Component Based Automation
arithmetic (CBA) on PROFINET
• Used as central controller in production lines with central and • PROFINET proxy for intelligent devices on PROFIBUS DP
distributed I/O in Component Based Automation (CBA)
• Component Based Automation (CBA) on PROFINET • PROFINET I/O Controller for operating distributed I/O
• PROFINET proxy for intelligent devices on PROFIBUS DP on PROFINET
in Component Based Automation (CBA) • For cross-industry automation tasks in series machine,
• PROFINET IO Controller for operating distributed I/O special machine and plant construction
on PROFINET • Used as central controller in production lines with central and
• PROFINET interface with 2-port switch distributed I/O
• Combined MPI/PROFIBUS DP master/slave interface • For comprehensive I/O expansion
• Isochronous mode on PROFIBUS • For configuring distributed I/O structures
• High processing performance in binary and floating-point
SIMATIC Micro Memory Card required for operation of CPU. arithmetic
Note: • Combined MPI/PROFIBUS DP master/slave interface
SIPLUS extreme products are based on SIMATIC standard • Optionally supports the use of SIMATIC engineering tools
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific Micro Memory Card required for operation of CPU.
information was added. Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1314-1AG14-7AB0 6AG1315-2AH14-7AB0
Based on 6ES7314-1AG14-0AB0 6ES7315-2AH14-0AB0
SIPLUS S7-300 CPU314 SIPLUS S7-300 CPU 315-2DP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1315-2EH14-7AB0 6AG1317-2EK14-7AB0
6ES7315-2EH14-0AB0 6ES7317-2EK14-0AB0
SIPLUS S7-300 CPU315-2PN/DP SIPLUS S7-300 CPU317-2PN/DP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; @ 60°C for UL/ATEX/FM use
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
5
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/fros 100 %; RH incl. condensation/frost
tested in accordance t (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
• The compact CPU with integral digital inputs/outputs • The compact CPU with integrated digital inputs/outputs as
• For small applications with increased processing well as second serial interface
performance requirements • For plants with high processing performance and response
• With technological functions time requirements
• With technological functions
SIMATIC Micro Memory Card required for operation of CPU.
SIMATIC Micro Memory Card required for operation of the CPU.
• The compact CPU with integral digital and analog inputs/ • The compact CPU with integral digital inputs/outputs and
outputs PROFIBUS DP master/slave interface
• For plants with high processing performance and response • For plants with high processing performance and response
time requirements time requirements
• With technological functions • With technological functions
SIMATIC Micro Memory Card required for operation of the CPU. • For tasks with special functions
• For connecting distributed I/Os
SIMATIC Micro Memory Card required for operation of CPU.
• The compact CPU with integrated digital and analog • The compact CPU with integral digital and analog
inputs/outputs as well as second serial interface inputs/outputs and technological functions
• For plants with high processing performance and response • High processing performance in binary and floating-point
time requirements arithmetic
• With technological functions • For connecting distributed I/O via PROFIBUS and PROFINET
SIMATIC Micro Memory Card required for operation of the CPU. • Combined MPI/PROFIBUS DP master/slave interface
• PROFINET interface with 2-port switch
■ Overview CPU 314C-2 DP • PROFINET IO controller for operating distributed I/O
on PROFINET
• PROFINET I-Device for connecting the CPU as an intelligent
PROFINET device under a SIMATIC or non-Siemens
PROFINET IO controller
• Component-based Automation (CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component-based Automation (CBA)
• Integrated web server with the option of creating user-defined
web pages
• Isochronous mode on PROFINET
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
Article number 6ES7312-5BF04-0AB0 6ES7313-5BG04-0AB0 6ES7313-6BG04-0AB0 6ES7313-6CG04-0AB0
CPU312C, 10DI/6DO, CPU313C, CPU313C-2 PTP, CPU313C-2 DP,
64 KB 24DI/16DO/5AI/2AO, 128 KB 16DI/16DO, 128 KB 16DI/16DO, 128 KB
Engineering with
• Programming package STEP 7 V5.5 + SP1 or higher STEP 7 V5.5 + SP1 or higher STEP 7 as of V5.5 + SP1 or STEP 7 V5.5 + SP1 or higher
or STEP 7 V5.3 + SP2 or or STEP 7 V5.3 + SP2 or STEP 7 V5.3 + SP2 or higher or STEP 7 V5.3 + SP2 or
higher with HSP 203 higher with HSP 203 with HSP 204 higher with HSP 203
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
Memory
Work memory
5 • integrated
• expandable
64 kbyte
No
128 kbyte
No
128 kbyte
No
128 kbyte
No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.1 µs 0.07 µs 0.07 µs 0.07 µs
for word operations, typ. 0.24 µs 0.15 µs 0.15 µs 0.15 µs
for fixed point arithmetic, typ. 0.32 µs 0.2 µs 0.2 µs 0.2 µs
for floating point arithmetic, typ. 1.1 µs 0.72 µs 0.72 µs 0.72 µs
Counters, timers and their
retentivity
S7 counter
• Number 256 256 256 256
IEC counter
• present Yes Yes Yes Yes
S7 times
• Number 256 256 256 256
IEC timer
• present Yes Yes Yes Yes
Data areas and their retentivity
Flag
• Size, max. 256 byte 256 byte 256 byte 256 byte
Address area
I/O address area
• Inputs 1 024 byte 1 024 byte 1 024 byte 2 048 byte
• Outputs 1 024 byte 1 024 byte 1 024 byte 2 048 byte
Process image
• Inputs, adjustable 1 024 byte 1 024 byte 1 024 byte 2 048 byte
• Outputs, adjustable 1 024 byte 1 024 byte 1 024 byte 2 048 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
• Software clock Yes
Operating hours counter
• Number 1 1 1 1
Digital inputs
integrated channels (DI) 10 24 16 16
Digital outputs
integrated channels (DO) 6 16 16 16
Analog inputs
integrated channels (AI) 0 5; 4x current/voltage, 0 0
1x resistance
Input ranges
• Voltage Yes; ±10 V / 100 kΩ;
0 V to 10 V / 100 kΩ
• Current Yes; ±20 mA / 100 Ω;
0 mA to 20 mA / 100 Ω;
4 mA to 20 mA / 100 Ω
• Resistance thermometer Yes; Pt 100 / 10 MΩ
• Resistance Yes; 0 Ω to 600 Ω / 10 MΩ
■ Technical specifications
Article number 6ES7312-5BF04-0AB0 6ES7313-5BG04-0AB0 6ES7313-6BG04-0AB0 6ES7313-6CG04-0AB0
CPU312C, 10DI/6DO, CPU313C, CPU313C-2 PTP, CPU313C-2 DP,
64 KB 24DI/16DO/5AI/2AO, 128 KB 16DI/16DO, 128 KB 16DI/16DO, 128 KB
Analog outputs
integrated channels (AO) 0 2 0 0
Output ranges, voltage
• 0 to 10 V Yes
• -10 V to +10 V Yes
Output ranges, current
• 0 to 20 mA Yes
• -20 mA to +20 mA Yes
• 4 mA to 20 mA Yes 5
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes
Protocols
• MPI Yes Yes Yes Yes
• PROFIBUS DP master No No No No
• PROFIBUS DP slave No No No No
• Point-to-point connection No No No No
2. Interface
Interface type Integrated Integrated
RS 422/ 485 interface RS 485 interface
Interface types
• RS 485 Yes; RS 422 / 485 (X.27) Yes
Protocols
• MPI No No
• PROFINET IO Controller No No
• PROFINET IO Device No No
• PROFINET CBA No No
• PROFIBUS DP master No Yes
• PROFIBUS DP slave No Yes
PROFIBUS DP master
• Number of DP slaves, max. 124
Communication functions
PG/OP communication Yes Yes Yes Yes
Data record routing No No No Yes
Global data communication
• supported Yes Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes; Server Yes
S7 communication
• supported Yes Yes Yes Yes
S5 compatible communication
• supported Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC
Number of connections
• overall 6 8 8 8
Integrated Functions
Frequency measurement Yes Yes Yes Yes
• Number of frequency meters 2; up to 10 kHz (see 3; up to 30 kHz (see 3; up to 30 kHz (see 3; up to 30 kHz (see
"Technological Functions" "Technological Functions" "Technological Functions" "Technological Functions"
manual) manual) manual) manual)
controlled positioning No No No No
integrated function blocks No Yes; PID controller (see Yes; PID controller (see Yes; PID controller (see
(closed-loop control) "Technological Functions" "Technological Functions" "Technological Functions"
manual) manual) manual)
PID controller No Yes Yes Yes
Number of pulse outputs 2; Pulse width modulation 3; Pulse width modulation 3; Pulse width modulation 3; Pulse width modulation
up to 2.5 kHz (see up to 2.5 kHz (see up to 2.5 kHz (see up to 2.5 kHz (see
"Technological Functions" "Technological Functions" "Technological Functions" "Technological Functions"
Manual) Manual) Manual) Manual)
Limit frequency (pulse) 2.5 kHz 2.5 kHz 2.5 kHz 2.5 kHz
■ Technical specifications
Article number 6ES7312-5BF04-0AB0 6ES7313-5BG04-0AB0 6ES7313-6BG04-0AB0 6ES7313-6CG04-0AB0
CPU312C, 10DI/6DO, CPU313C, CPU313C-2 PTP, CPU313C-2 DP,
64 KB 24DI/16DO/5AI/2AO, 128 KB 16DI/16DO, 128 KB 16DI/16DO, 128 KB
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
5 - LAD
- FBD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
- STL Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes Yes
- HiGraph® Yes Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 80 mm 120 mm 80 mm 80 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm 130 mm
Weights
Weight, approx. 410 g 660 g 500 g 500 g
■ Technical specifications
Article number 6ES7314-6BH04-0AB0 6ES7314-6CH04-0AB0 6ES7314-6EH04-0AB0
CPU314C-2PTP, CPU314C-2DP, CPU314C-2PN/DP,
24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/4AI/2AO, 192KB
Data areas and their retentivity
Flag
• Size, max. 256 byte 256 byte 256 byte
Address area
I/O address area
• Inputs 1 024 byte 2 048 byte 2 048 byte
• Outputs 1 024 byte 2 048 byte 2 048 byte
5
Process image
• Inputs, adjustable 1 024 byte 2 048 byte 2 048 byte
• Outputs, adjustable 1 024 byte 2 048 byte 2 048 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Operating hours counter
• Number 1 1 1
Digital inputs
integrated channels (DI) 24 24 24
Digital outputs
integrated channels (DO) 16 16 16
Analog inputs
integrated channels (AI) 5; 4x current/voltage, 1x resistance 5; 4x current/voltage, 1x resistance 5; 4x current/voltage, 1x resistance
Input ranges
• Voltage Yes; ±10 V / 100 kΩ; Yes; ±10 V / 100 kΩ; Yes; ±10 V / 100 kΩ;
0 V to 10 V / 100 kΩ 0 V to 10 V / 100 kΩ 0 V to 10 V / 100 kΩ
• Current Yes; ±20 mA / 100 Ω; Yes; ±20 mA / 100 Ω; Yes; ±20 mA / 100 Ω;
0 mA to 20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω;
4 mA to 20 mA / 100 Ω 4 mA to 20 mA / 100 Ω 4 mA to 20 mA / 100 Ω
• Resistance thermometer Yes; Pt 100 / 10 MΩ Yes; Pt 100 / 10 MΩ Yes; Pt 100 / 10 MΩ
• Resistance Yes; 0 Ω to 600 Ω / 10 MΩ Yes; 0 Ω to 600 Ω / 10 MΩ Yes; 0 Ω to 600 Ω / 10 MΩ
Analog outputs
integrated channels (AO) 2 2 2
Output ranges, voltage
• 0 to 10 V Yes Yes Yes
• -10 V to +10 V Yes Yes Yes
Output ranges, current
• 0 to 20 mA Yes Yes Yes
• -20 mA to +20 mA Yes Yes Yes
• 4 mA to 20 mA Yes Yes Yes
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes
Protocols
• MPI Yes Yes Yes
• PROFIBUS DP master No No Yes
• PROFIBUS DP slave No No Yes
• Point-to-point connection No No No
PROFIBUS DP master
• Number of DP slaves, max. 124
■ Technical specifications
Article number 6ES7314-6BH04-0AB0 6ES7314-6CH04-0AB0 6ES7314-6EH04-0AB0
CPU314C-2PTP, CPU314C-2DP, CPU314C-2PN/DP,
24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/4AI/2AO, 192KB
2. Interface
Interface type Integrated RS 422/ 485 interface Integrated RS 485 interface
Interface types
• RJ 45 (Ethernet) Yes
• RS 485 Yes; RS 422 / 485 (X.27) Yes
• Number of ports 2
Protocols
• MPI No No No
5 • PROFINET IO Controller No No Yes; Also simultaneously
with IO-Device functionality
• PROFINET IO Device No No Yes; Also simultaneously
with IO Controller functionality
• PROFINET CBA No No Yes
• PROFIBUS DP master No Yes No
• PROFIBUS DP slave No Yes No
PROFIBUS DP master
• Number of DP slaves, max. 124
PROFINET IO Controller
Services
- Number of connectable 128
IO Devices, max.
- Of which IO devices with IRT, max. 64
- Number of IO Devices with IRT and 128
the option "high flexibility"
- Number of connectable 128
IO Devices for RT, max.
Protocols
Open IE communication
• TCP/IP Yes; via integrated PROFINET interface
and loadable FBs
- Number of connections, max. 8
• ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface
and loadable FBs
- Number of connections, max. 8
• UDP Yes; via integrated PROFINET interface
and loadable FBs
- Number of connections, max. 8
Web server
• supported Yes
Communication functions
PG/OP communication Yes Yes Yes
Data record routing No Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
• supported Yes Yes Yes
S5 compatible communication
• supported Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC
Number of connections
• overall 12 12 12
■ Technical specifications
Article number 6ES7314-6BH04-0AB0 6ES7314-6CH04-0AB0 6ES7314-6EH04-0AB0
CPU314C-2PTP, CPU314C-2DP, CPU314C-2PN/DP,
24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/5AI/2AO, 192 KB 24DI/16DO/4AI/2AO, 192KB
Integrated Functions
Frequency measurement Yes Yes Yes
• Number of frequency meters 4; up to 60 kHz (see 4; up to 60 kHz (see 4; up to 60 kHz (see
"Technological Functions" manual) "Technological Functions" manual) "Technological Functions" manual)
controlled positioning Yes Yes Yes
integrated function blocks Yes; PID controller (see Yes; PID controller (see Yes; PID controller (see
(closed-loop control) "Technological Functions" manual) "Technological Functions" manual) "Technological Functions" manual)
PID controller Yes Yes Yes
Number of pulse outputs 4; Pulse width modulation
up to 2.5 kHz (see "Technological
Functions" Manual)
4; Pulse width modulation
up to 2.5 kHz (see "Technological
Functions" Manual)
4; Pulse width modulation
up to 2.5 kHz (see "Technological
Functions" Manual)
5
Limit frequency (pulse) 2.5 kHz 2.5 kHz 2.5 kHz
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 120 mm 120 mm 120 mm
Height 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm
Weights
Weight, approx. 680 g 680 g 730 g
• The compact CPU with integral digital inputs/outputs • The compact CPU with integral digital inputs/outputs and
• For small applications with increased processing PROFIBUS DP master/slave interface
performance requirements • With technological functions
• With technological functions • For tasks with special functions
Micro Memory Card required for operation of CPU. • For connecting distributed I/O
Note: Micro Memory Card required for operation of CPU.
SIPLUS extreme products are based on SIMATIC standard Note:
products. The contents listed here were taken from the SIPLUS extreme products are based on SIMATIC standard
respective standard products. SIPLUS extreme-specific products. The contents listed here were taken from the
information was added. respective standard products. SIPLUS extreme-specific
information was added.
• The compact CPU with integrated digital and analog • The compact CPU with integrated digital and analog
inputs/outputs inputs/outputs as well as second serial interface
• For plants with high processing performance and response • For plants with high processing performance and response
time requirements time requirements
• With technological functions • With technological functions
Micro Memory Card required for operation of CPU. SIMATIC Micro Memory Card required for operation of CPU.
Note: Note:
SIPLUS extreme products are based on SIMATIC standard SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the products. The contents listed here were taken from the
corresponding standard products. SIPLUS extreme-specific respective standard products. SIPLUS extreme-specific
information was added. information was added.
• The compact CPU with integral digital and analog inputs/ • The compact CPU with integral digital and analog inputs/
outputs and PROFIBUS DP master/slave interface outputs and technological functions
• With technological functions • High processing performance in binary and floating-point
• For tasks with special functions arithmetic
• For connecting distributed I/O • For connecting distributed I/O via PROFIBUS and PROFINET
• Combined MPI/PROFIBUS DP master/slave interface
Micro Memory Card required for operation of CPU.
• PROFINET interface with 2-port switch
Note:
• PROFINET IO controller for operating distributed I/O
SIPLUS extreme products are based on SIMATIC standard on PROFINET
products. The contents listed here were taken from the • PROFINET I-Device for connecting the CPU as intelligent
respective standard products. SIPLUS extreme-specific PROFINET device under a SIMATIC or non-Siemens
information was added. PROFINET I/O controller
• Component based Automation (CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component based Automation (CBA)
• Integrated web server with the option of creating user-defined
web pages
• Isochronous mode on PROFINET
SIMATIC Micro Memory Card required for operation of CPU.
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1312-5BF04-7AB0 6AG1313-5BG04-7AB0
Based on 6ES7312-5BF04-0AB0 6ES7313-5BG04-0AB0
SIPLUS S7-300 CPU312C SIPLUS S7-300 CPU313C
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
5 max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1313-6CG04-7AB0 6AG1314-6BH04-7AB0
Based on 6ES7313-6CG04-0AB0 6ES7314-6BH04-0AB0
SIPLUS S7-300 CPU313C-2DP SIPLUS S7-300 CPU314C-2 PtP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
5
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high availability
assemblies acc. to EN 61086
• Military testing according to Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
■ Technical specifications
Article number 6AG1314-6CH04-7AB0 6AG1314-6EH04-7AB0
Based on 6ES7314-6CH04-0AB0 6ES7314-6EH04-0AB0
SIPLUS S7-300 CPU314C-2DP SIPLUS S7-300 CPU314C-2PN/DP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; @ 60°C for UL/ATEX/FM use
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
5 max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hP Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude a (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
• Based on CPU 317-2 PN/DP • The fail-safe CPU with high-performance command
• The fail-safe CPU with a large program memory and quantity processing, large program memory and large quantity
framework for demanding applications; for setting up a structure for demanding applications
fail-safe automation system in plants with increased safety • For constructing a fail-safe automation system for plants with
requirements. increased safety requirements
• Complies with safety requirements to SIL 3 acc. to IEC 61508 • Complies with safety requirements to SIL 3 acc. to IEC 61508
and PL e acc. to ISO 13849.1 and PL e acc. to 13849.1
• Distributed fail-safe I/O modules can be locally connected via • Distributed fail-safe I/O modules can be locally connected via
the integrated PROFINET interface (PROFIsafe) and/or via the the integrated PROFINET interface (PROFIsafe) and/or via the
integrated PROFIBUS DP interface (PROFIsafe) integrated PROFIBUS DP interface (PROFIsafe);
• Fail-safe ET 200M I/O modules • Fail-safe ET 200M I/O modules can also be connected
• can also be connected centrally centrally
• Central and distributed use of standard modules for • Standard modules for non-safety-related applications can be
non safety-oriented applications operated centrally and locally
• Component-based Automation (CBA) on PROFINET • Distributed intelligence in Component Based Automation
(CBA) on PROFINET
• PROFINET IO controller for operating distributed I/O
on PROFINET • Isochronous mode on PROFIBUS
• PROFINET interface with 2-port switch • PROFINET proxy for intelligent devices on PROFIBUS DP
in Component Based Automation (CBA)
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component-based Automation (CBA) SIMATIC Micro Memory Card required for operation of CPU.
SIMATIC Micro Memory Card required for operation of CPU.
■ Technical specifications
Article number 6ES7315-6FF04-0AB0 6ES7315-2FJ14-0AB0 6ES7317-6FF04-0AB0 6ES7317-2FK14-0AB0 6ES7318-3FL01-0AB0
CPU315F, 384KB CPU315F-2 PN/DP, CPU317F-2DP, 1.5 MB CPU317F-2 PN/DP, CPU319F-3 PN/DP,
512 KB 1.5 MB 2.5 MB
General information
Product function
• Isochronous mode Yes Yes; Via PROFIBUS DP Yes; Via PROFIBUS DP Yes;
or PROFINET interface or PROFINET interface Via 2nd PROFIBUS DP
or PROFINET interface
Engineering with
• Programming package STEP 7 V5.5 + SP1 or STEP 7 V5.5 or higher, STEP 7 V5.5 + SP1 or STEP 7 V5.5 or higher, STEP 7 V5.5 or higher,
higher or STEP 7 V5.2 Distributed Safety V5.4 higher or STEP 7 V5.2 Distributed Safety V5.4 Distributed Safety V5.4
+ SP1 or higher with SP4 + SP1 or higher with SP4 SP4
HSP 218 + Distributed HSP 202 + Distributed
Safety Safety
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V 24 V
■ Technical specifications
Article number 6ES7315-6FF04-0AB0 6ES7315-2FJ14-0AB0 6ES7317-6FF04-0AB0 6ES7317-2FK14-0AB0 6ES7318-3FL01-0AB0
CPU315F, 384KB CPU315F-2 PN/DP, CPU317F-2DP, 1.5 MB CPU317F-2 PN/DP, CPU319F-3 PN/DP,
512 KB 1.5 MB 2.5 MB
Memory
Work memory
• integrated 384 kbyte 512 kbyte 1 536 kbyte 1 536 kbyte 2 560 kbyte
• expandable No No No No No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.05 µs 0.025 µs 0.025 µs 0.004 µs
for word operations, typ. 0.09 µs 0.09 µs 0.03 µs 0.03 µs 0.01 µs 5
for fixed point arithmetic, typ. 0.12 µs 0.12 µs 0.04 µs 0.04 µs 0.01 µs
for floating point arithmetic, typ. 0.45 µs 0.45 µs 0.16 µs 0.16 µs 0.04 µs
Counters, timers and their
retentivity
S7 counter
• Number 256 256 512 512 2 048
IEC counter
• present Yes Yes Yes Yes Yes
S7 times
• Number 256 256 512 512 2 048
IEC timer
• present Yes Yes Yes Yes Yes
Data areas and their retentivity
Flag
• Size, max. 2 048 byte 2 048 byte 4 096 byte 4 096 byte 8 192 byte
Address area
I/O address area
• Inputs 2 048 byte 2 048 byte 8 192 byte 8 192 byte 8 192 byte
• Outputs 2 048 byte 2 048 byte 8 192 byte 8 192 byte 8 192 byte
Process image
• Inputs, adjustable 2 048 byte 2 048 byte 8 192 byte 8 192 byte 8 192 byte
• Outputs, adjustable 2 048 byte 2 048 byte 8 192 byte 8 192 byte 8 192 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes Yes Yes
Operating hours counter
• Number 1 1 4 4 4
1. Interface
Interface type Integrated Integrated Integrated Integrated RS 485 Integrated
RS 485 interface RS 485 interface RS 485 interface interface RS 485 interface
Interface types
• RS 485 Yes Yes Yes Yes Yes
Protocols
• MPI Yes Yes Yes Yes Yes
• PROFIBUS DP master No Yes Yes Yes Yes
• PROFIBUS DP slave No Yes Yes; A DP slave Yes Yes; A DP slave
at both interfaces at both interfaces
simultaneously is simultaneously is
not possible not possible
• Point-to-point connection No No No No No
PROFIBUS DP master
• Number of DP slaves, max. 124 124 124 124
■ Technical specifications
Article number 6ES7315-6FF04-0AB0 6ES7315-2FJ14-0AB0 6ES7317-6FF04-0AB0 6ES7317-2FK14-0AB0 6ES7318-3FL01-0AB0
CPU315F, 384KB CPU315F-2 PN/DP, CPU317F-2DP, 1.5 MB CPU317F-2 PN/DP, CPU319F-3 PN/DP,
512 KB 1.5 MB 2.5 MB
2. Interface
Interface type Integrated Integrated Integrated
RS 485 interface RS 485 interface RS 485 interface
Interface types
• RJ 45 (Ethernet) Yes Yes
• RS 485 Yes Yes Yes
• Number of ports 2 2
Protocols
5 • MPI
• PROFINET IO Controller
No No
Yes; Also
No No
Yes; Also
No
No
simultaneously with simultaneously with
IO-Device functionality IO-Device functionality
• PROFINET IO Device Yes; Yes; No
Also simultaneously Also simultaneously
with IO Controller with IO Controller
functionality functionality
• PROFINET CBA Yes Yes No
• PROFIBUS DP master Yes No Yes No Yes
• PROFIBUS DP slave Yes No Yes; A DP slave No Yes; A DP slave
at both interfaces at both interfaces
simultaneously is simultaneously is
not possible not possible
PROFIBUS DP master
• Number of DP slaves, max. 124; Per station 124 124
PROFINET IO Controller
Services
- Number of connectable 128 128
IO Devices, max.
- Of which IO devices with IRT, max. 64 64
- Number of IO Devices with IRT and 128 128
the option "high flexibility"
- Number of connectable 128 128
IO Devices for RT, max.
3. Interface
Interface types
• RJ 45 (Ethernet) Yes
• Number of ports 2
Protocols
• MPI No
• PROFINET IO Controller Yes; Also
simultaneously with
I-Device functionality
• PROFINET IO Device Yes;
Also simultaneously
with IO Controller
functionality
• PROFINET CBA Yes
• PROFIBUS DP master No
• PROFIBUS DP slave No
PROFINET IO Controller
Services
- Number of connectable 256
IO Devices, max.
- Of which IO devices with IRT, max. 64
- Number of IO Devices with IRT and 256
the option "high flexibility"
- Number of connectable 256
IO Devices for RT, max.
■ Technical specifications
Article number 6ES7315-6FF04-0AB0 6ES7315-2FJ14-0AB0 6ES7317-6FF04-0AB0 6ES7317-2FK14-0AB0 6ES7318-3FL01-0AB0
CPU315F, 384KB CPU315F-2 PN/DP, CPU317F-2DP, 1.5 MB CPU317F-2 PN/DP, CPU319F-3 PN/DP,
512 KB 1.5 MB 2.5 MB
Protocols
Open IE communication
• TCP/IP Yes; via integrated Yes; via integrated Yes; via integrated
PROFINET interface PROFINET interface PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
• ISO-on-TCP (RFC1006) Yes; via integrated Yes; via integrated Yes; via integrated
PROFINET interface PROFINET interface PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max.
• UDP
8
Yes; via integrated
16
Yes; via integrated
32
Yes; via integrated
5
PROFINET interface PROFINET interface PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 32
Web server
• supported Yes; only read function Yes Yes
Communication functions
PG/OP communication Yes Yes Yes Yes Yes
Data record routing Yes Yes Yes Yes Yes
Global data communication
• supported Yes Yes Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes Yes Yes
S7 communication
• supported Yes Yes Yes Yes Yes
S5 compatible communication
• supported Yes; via CP and Yes; via CP and Yes; via CP and Yes; via CP and Yes; via CP and
loadable FC loadable FC loadable FC loadable FC loadable FC
Number of connections
• overall 16 16 32 32 32
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
- LAD Yes Yes Yes Yes Yes
- FBD Yes Yes Yes Yes Yes
- STL Yes Yes Yes Yes Yes
- SCL Yes Yes Yes Yes Yes
- CFC Yes Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes Yes
- HiGraph® Yes Yes Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Yes; With S7 block Yes; With S7 block Yes; With S7 block Yes; With S7 block
Privacy Privacy Privacy Privacy Privacy
Dimensions
Width 40 mm 40 mm 40 mm 40 mm 120 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm 130 mm 130 mm
Weights
Weight, approx. 290 g 340 g 360 g 340 g 1 250 g
• For configuring a fail-safe automation system for plants with • The CPU with a medium sized program memory and quantity
increased safety requirements structures to build a fail-safe automation system for plants with
• Complies with safety requirements up to SIL 3 according to increased safety requirements
IEC 61508 and up to Cat. 4 according to EN 954-1 • Complies with safety requirements up to SIL 3 according to
• Distributed fail-safe I/O modules can be connected through IEC 61508, PL e in accordance with ISO 13849 and up to
the integral PROFIBUS DP interface (PROFIsafe) Cat. 4 of EN 954-1
• Fail-safe ET 200M I/O modules are also centrally connectable • The fail-safe I/O modules can be locally connected to the
integrated PROFINET interface (PROFIsafe) and/or to the
• The standard modules for non-safety applications can be integrated PROFIBUS DP interface (PROFIsafe)
operated both centrally and locally
• Fail-safe ET 200M I/O modules are also centrally connectable
Micro Memory Card required for operation of CPU. • The standard modules for non-safety applications can be
Note: operated both centrally and locally
SIPLUS extreme products are based on SIMATIC standard • Component Based Automation (CBA) on PROFINET
products. The contents listed here were taken from the • PROFINET IO controller for operating distributed I/O
respective standard products. SIPLUS extreme-specific on PROFINET
information was added. • PROFINET interface with 2-port switch
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component Based Automation (CBA)
Micro Memory Card required for operation of CPU.
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
• The fail-safe CPU with a large program memory and quantity • The failsafe CPU with a large program memory and quantity
framework for demanding applications structures for demanding applications to build a fail-safe
• For configuring a fail-safe automation system for plants with automation system for plants with increased safety
increased safety requirements requirements
• Complies with safety requirements up to SIL 3 according to • Complies with safety requirements up to SIL 3 according to
IEC 61508 and up to Cat. 4 according to EN 954-1 IEC 61508, PL e in accordance with ISO 13849-1 and up to
category 4 of EN 954-1
• Fail-safe I/O modules can be connected in a distributed
configuration to both integral PROFIBUS DP interfaces • The fail-safe I/O modules can be locally connected via the
(PROFIsafe) integrated PROFINET interface (PROFIsafe) and/or via the
integrated PROFIBUS DP interface (PROFIsafe)
• Fail-safe ET 200M I/O modules are also centrally connectable
• Fail-safe ET 200M I/O modules are also centrally connectable
• The standard modules for non-safety applications can be
operated both centrally and locally • The standard modules for non-safety applications can be
operated both centrally and locally
Micro Memory Card required for operation of CPU. • Component Based Automation (CBA) on PROFINET
Note: • PROFINET IO Controller for operating distributed I/O
SIPLUS extreme products are based on SIMATIC standard on PROFINET
products. The contents listed here were taken from the • PROFINET interface with 2-port switch
respective standard products. SIPLUS extreme-specific • PROFINET proxy for intelligent devices on PROFIBUS DP
information was added. in Component Based Automation (CBA)
SIMATIC Micro Memory Card required for operation of CPU.
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1315-6FF04-2AB0 6AG1315-2FJ14-2AB0
Based on 6ES7315-6FF04-0AB0 6ES7315-2FJ14-0AB0
SIPLUS S7-300 CPU 315F-2DP SIPLUS S7-300 CPU315F-2PN/DP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C -25 °C; = Tmin
• max. 60 °C 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
5 max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1317-6FF04-2AB0 6AG1317-2FK14-2AB0
Based on 6ES7317-6FF04-0AB0 6ES7317-2FK14-0AB0
SIPLUS S7-300 CPU317F-2DP SIPLUS S7-300 CPU317F-2PN/DP
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 60 °C; = Tmax 60 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
5
barometric pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
• SIMATIC CPU with integral technology/motion control • SIMATIC CPU with integral technology/motion control
functionality functionality
• With full standard CPU 315-2 PN/DP functionality • With full standard CPU 317-2 PN/DP functionality
(except for CBA) (except for CBA)
• For cross-industry automation tasks in series machine, • For cross-industry automation tasks in series machine,
special machine and plant construction special machine and plant construction
• Ideal for synchronized motion, such as coupling to a • Ideal for synchronized motion, such as coupling to a
virtual/real master, gear synchronization, cam disk, virtual/real master, gear synchronization, cam disk,
path interpolation, or print mark compensation path interpolation, or print mark compensation
• 3D path interpolation with different kinematics • 3D path interpolation with different kinematics
• Position and pressure-regulated hydraulic axes • Position and pressure-regulated hydraulic axes
• Used as central controller in production lines with central and • Used as central controller in production lines with central and
distributed I/O distributed I/O
• With integrated I/O for high-speed technology functions • With integrated I/O for high-speed technology functions
(e.g. camming, reference point acquisition) (e.g. camming, reference point acquisition)
• PROFIBUS DP (DRIVE) interface for isochronous connection • PROFIBUS DP (DRIVE) interface for isochronous connection
of drive components of drive components
• PROFINET interface with 2-port switch • PROFINET interface with 2-port switch
• PROFINET IO controller for operating distributed I/O • PROFINET IO controller for operating distributed I/O
on PROFINET on PROFINET
• One common S7 user program for control and motion control • One common S7 user program for control and motion control
tasks (no additional programming language necessary for tasks (no additional programming language necessary for
motion control) motion control)
• "S7 Technology" option package required • "S7 Technology" option package required
(version V4.2 SP3 and higher) (version V4.2 SP3 and higher)
SIMATIC Micro Memory Card (8 MB) required for operation of the SIMATIC Micro Memory Card (8 MB) required for operation of the
CPU. CPU.
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
5 (64-bit),
Windows Server 2012 R2 (64-bit),
with laser printer; 10 units
Petrol 6ES7392-2AX10-0AA0
Windows Server 2016 (64-bit);
STEP 7 from V5.5 SP1; Light beige 6ES7392-2BX10-0AA0
Please also note the operating
systems that have been released Yellow 6ES7392-2CX10-0AA0
for the STEP 7 version used Red 6ES7392-2DX10-0AA0
Floating license for 1 user; software 6ES7833-1FC02-0YA5 USB A2 PC adapter 6GK1571-0BA00-0AA0
and documentation on DVD;
license key on USB flash drive For connecting a programming
device/PC or Notebook to
Floating license for 1 user; software, 6ES7833-1FC02-0YH5 PROFIBUS or MPI; USB cable
documentation and license key for included in scope of delivery
download1);
email address required for delivery PROFIBUS bus components
S7 Distributed Safety upgrade PROFIBUS DP RS 485
bus connector
From V5.x to V5.4; 6ES7833-1FC02-0YE5 • With 90° cable outlet,
floating license for 1 user; software max. transfer rate 12 Mbps
and documentation on DVD;
license key on USB flash drive - Without programming device 6ES7972-0BA12-0XA0
interface
SIMATIC Micro Memory Card - With programming device 6ES7972-0BB12-0XA0
8 MB 6ES7953-8LP31-0AA0 interface
• With 90° cable outlet for
MPI cable 6ES7901-0BF00-0AA0 FastConnect connection system,
For connection of SIMATIC S7 and max. transfer rate 12 Mbps
programming device via MPI; - Without programming device 6ES7972-0BA52-0XA0
length 5 m interface, 1 unit
- Without programming device 6ES7972-0BA52-0XB0
Front connector interface, 100 units
40-pin, with screw contacts - With programming device 6ES7972-0BB52-0XA0
• 1 unit 6ES7392-1AM00-0AA0 interface, 1 unit
• 100 units 6ES7392-1AM00-1AB0 - With programming device 6ES7972-0BB52-0XB0
interface, 100 units
40-pin, with spring-loaded contacts • With axial cable outlet for 6GK1500-0EA02
• 1 unit 6ES7392-1BM01-0AA0 SIMATIC OP, for connecting to
• 100 units 6ES7392-1BM01-1AB0 PPI, MPI, PROFIBUS
Slot number plates 6ES7912-0AA00-0AA0 PROFIBUS FastConnect 6XV1830-0EH10
bus cable
SIMATIC Manual Collection 6ES7998-8XC01-8YE0
Standard type with special design
Electronic manuals on DVD, for quick mounting, 2-wire,
multi-language: shielded, sold by the meter,
LOGO!, SIMADYN, max. delivery unit 1 000 m,
SIMATIC bus components, minimum order quantity 20 m
SIMATIC C7,
SIMATIC Distributed I/O, RS 485 repeater for PROFIBUS 6ES7972-0AA02-0XA0
SIMATIC HMI, SIMATIC Sensors,
SIMATIC NET, SIMATIC PC-based Transmission rate up to 12 Mbps;
Automation, SIMATIC PCS 7, 24 V DC; IP20 enclosure
SIMATIC PG/PC, SIMATIC S7,
SIMATIC Software, SIMATIC TDC
SIMATIC Manual Collection 6ES7998-8XC01-8YE2
update service for 1 year
Current Manual Collection DVD and
the three subsequent updates
1)
For up-to-date information and download availability, see:
http://www.siemens.com/tia-online-software-delivery
■ Technical specifications
Article number 6ES7315-7TJ10-0AB0 6ES7317-7TK10-0AB0 6ES7317-7UL10-0AB0
CPU315T-3 PN/DP, 384KB CPU317T-3 PN/DP, 1024KB CPU317TF-3 PN/DP, 1,5 MB
General information
Product function
• Isochronous mode Yes; Via PROFIBUS DP or Yes; Via PROFIBUS DP or Yes; Via PROFIBUS DP or
PROFINET interface PROFINET interface PROFINET interface
Engineering with
• Programming package STEP 7 V5.5 SP2 or higher and STEP 7 V5.5 SP2 or higher and STEP 7 V5.5 SP2 or higher;
S7-Technology option package V4.2 S7-Technology option package V4.2 S7-Technology option package V4.2
SP3 SP3 SP3 or higher, Distributed Safety V5.4
SP5 or higher, S7-F Configuration Pack
V5.5 SP10 or higher
Supply voltage
Rated value (DC) 24 V 24 V 24 V
Memory
Work memory
• integrated 384 kbyte 1 024 kbyte 1 536 kbyte
• expandable No No No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs 0.025 µs
for word operations, typ. 0.09 µs 0.03 µs 0.03 µs
for fixed point arithmetic, typ. 0.12 µs 0.04 µs 0.04 µs
for floating point arithmetic, typ. 0.45 µs 0.16 µs 0.16 µs
■ Technical specifications
Article number 6ES7315-7TJ10-0AB0 6ES7317-7TK10-0AB0 6ES7317-7UL10-0AB0
CPU315T-3 PN/DP, 384KB CPU317T-3 PN/DP, 1024KB CPU317TF-3 PN/DP, 1,5 MB
Counters, timers and their
retentivity
S7 counter
• Number 256 512 512
IEC counter
• present Yes Yes Yes
S7 times
• Number 256 512 512
5
IEC timer
• present Yes Yes Yes
Data areas and their retentivity
Flag
• Size, max. 2 048 byte 4 096 byte 4 096 byte
Address area
I/O address area
• Inputs 2 048 byte 8 192 byte 8 192 byte
• Outputs 2 048 byte 8 192 byte 8 192 byte
Process image
• Inputs, adjustable 2 048 byte 8 192 byte 8 192 byte
• Outputs, adjustable 2 048 byte 8 192 byte 8 192 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes Yes
Operating hours counter
• Number 1 4 4
Digital outputs
Integrated high-speed cams
• Switching accuracy (+/-) 70 µs 70 µs 70 µs
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes
Protocols
• MPI Yes Yes Yes
• PROFIBUS DP master Yes Yes Yes
• PROFIBUS DP slave Yes Yes Yes
• Point-to-point connection No No No
PROFIBUS DP master
• Number of DP slaves, max. 124 124 124
2. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes Yes
Protocols
• MPI No No No
• PROFIBUS DP master Yes; DP(DRIVE)-Master Yes; DP(DRIVE)-Master Yes; DP(DRIVE)-Master
• PROFIBUS DP slave No No No
PROFIBUS DP master
• Number of DP slaves, max. 64 64 64
3. Interface
Interface types
• RJ 45 (Ethernet) Yes Yes Yes
• Number of ports 2 2 2
Protocols
• MPI No No No
• PROFINET IO Controller Yes; Also simultaneously Yes; Also simultaneously Yes; Also simultaneously
with IO-Device functionality with IO-Device functionality with IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously Yes; Also simultaneously Yes; Also simultaneously
with IO Controller functionality with IO Controller functionality with IO Controller functionality
• PROFIBUS DP master No No No
• PROFIBUS DP slave No No No
■ Technical specifications
Article number 6ES7315-7TJ10-0AB0 6ES7317-7TK10-0AB0 6ES7317-7UL10-0AB0
CPU315T-3 PN/DP, 384KB CPU317T-3 PN/DP, 1024KB CPU317TF-3 PN/DP, 1,5 MB
PROFINET IO Controller
Services
- Number of connectable 128 128 128
IO Devices, max.
- Of which IO devices with IRT, max. 64 64 64
- Number of connectable 128 128 128
IO Devices for RT, max.
Protocols
Open IE communication
• TCP/IP Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
5
- Number of connections, max. 8 16 16
• ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 16
• UDP Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface Yes; via integrated PROFINET interface
and loadable FBs and loadable FBs and loadable FBs
- Number of connections, max. 8 16 16
Web server
• supported Yes Yes Yes
Communication functions
PG/OP communication Yes Yes Yes
Data record routing Yes Yes Yes
Global data communication
• supported Yes Yes Yes
S7 basic communication
• supported Yes Yes Yes
S7 communication
• supported Yes Yes Yes
S5 compatible communication
• supported Yes; via CP and loadable FC Yes; via CP and loadable FC Yes; via CP and loadable FC
Number of connections
• overall 16 32 32
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C 0 °C
• max. 60 °C 60 °C 60 °C
Configuration
Programming
Programming language
- LAD Yes Yes Yes
- FBD Yes Yes Yes
- STL Yes Yes Yes
- SCL Yes Yes Yes
- CFC Yes Yes Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Know-how protection
• User program protection/ Yes Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 120 mm 120 mm 120 mm
Height 125 mm 125 mm 125 mm
Depth 130 mm 130 mm 130 mm
Weights
Weight, approx. 640 g 640 g 640 g
■ Overview
• Digital inputs
• For connecting standard switches and two-wire proximity
switches (BEROs)
■ Technical specifications
Article number 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BP00-0AA0 6ES7321-1BH10-0AA0
SM321, 16DI, DC24V SM321, 16DI, DC24V, SM321, 32DI, DC24V SM321, 64 DI, DC 24V, SM321,16DI,DC24V,
Source Input 3MS, P/M reading 0.05ms Input Delay.
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V 24 V 24 V
Input current
from backplane bus 5 V DC, max. 10 mA 10 mA 15 mA 100 mA 110 mA
Power loss
Power loss, typ. 3.5 W 3.5 W 6.5 W 7W 3.8 W
Digital inputs
Number of digital inputs 16 16 32 64 16
Input characteristic curve Yes Yes Yes Yes Yes
in accordance with IEC 61131, type 1
Input voltage
• Type of input voltage DC DC DC DC DC
• Rated value (DC) 24 V 24 V 24 V 24 V 24 V
• for signal "0" -30 to +5 V -5 to +30V -30 to +5 V -30 to +5 V -30 to +5 V
• for signal "1" 13 to 30V -13 to -30V 13 to 30V 13 to 30V 13 to 30V
Input current
• for signal "1", typ. 7 mA 7 mA 7 mA 4.2 mA 7 mA
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable No No No No No
- at "0" to "1", min. 1.2 ms 1.2 ms 1.2 ms 1.2 ms 25 µs
- at "0" to "1", max. 4.8 ms 4.8 ms 4.8 ms 4.8 ms 75 µs
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m
■ Technical specifications
Article number 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BP00-0AA0 6ES7321-1BH10-0AA0
SM321, 16DI, DC24V SM321, 16DI, DC24V, SM321, 32DI, DC24V SM321, 64 DI, DC 24V, SM321,16DI,DC24V,
Source Input 3MS, P/M reading 0.05ms Input Delay.
Encoder
Connectable encoders
• 2-wire sensor Yes Yes Yes No Yes
- permissible quiescent current 1.5 mA 1.5 mA 1.5 mA 1.5 mA
(2-wire sensor), max.
Interrupts/diagnostics/
status information
Alarms No No No No No
5 Diagnostics function
Alarms
No No No No No
• Diagnostic alarm No No No No No
• Hardware interrupt No No No No No
Connection method
required front connector 20-pin 20-pin 40-pin Cable: 20-pin
6ES7392-4Bxx0-0AA0
terminal blocks:
6ES7392-1xN00-0AA0
Dimensions
Width 40 mm 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm 112 mm 120 mm
Weights
Weight, approx. 200 g 200 g 260 g 230 g 200 g
■ Technical specifications
Article number 6ES7321-7BH01-0AB0 6ES7321-1CH00-0AA0 6ES7321-1CH20-0AA0 6ES7321-1FH00-0AA0
SM321, 16DI, 24V DC SM321, 16 DI, SM321, 16DI, DC48-125V SM321, 16 DI, 120/230V AC
AC/DC 24-48V, 1ch/common
Input delay
(for rated value of input voltage)
for standard inputs
- parameterizable Yes; 0.1 / 0.5 / 3 / 15 / 20 ms No No No
- at "0" to "1", min. 16 ms 0.1 ms 25 ms
- at "0" to "1", max. 16 ms 3.5 ms 25 ms
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m
Encoder
Connectable encoders
5
• 2-wire sensor Yes Yes Yes Yes
- permissible quiescent current 2 mA 1 mA 1 mA 2 mA
(2-wire sensor), max.
Interrupts/diagnostics/
status information
Alarms Yes No No No
Diagnostics function Yes; Parameterizable No No No
Alarms
• Diagnostic alarm Yes; Parameterizable No No No
• Hardware interrupt Yes; Parameterizable No No No
Connection method
required front connector 20-pin 40-pin 20-pin 20-pin
Dimensions
Width 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm 120 mm
Weights
Weight, approx. 200 g 260 g 200 g 240 g
■ Technical specifications
Article number 6ES7321-1EL00-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF10-0AA0
SM321, 32DI, AC120V SM321, 8DI, AC120/230V SM321, 8 DI, AC/DC 120/230V,
1ch/common
Encoder
Connectable encoders
• 2-wire sensor Yes Yes Yes
- permissible quiescent current 4 mA 2 mA 2 mA
(2-wire sensor), max.
Interrupts/diagnostics/
status information
Alarms No No No
5 Diagnostics function
Alarms
No No No
• Diagnostic alarm No No No
• Hardware interrupt No No No
Connection method
required front connector 40-pin 20-pin 40-pin
Dimensions
Width 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm
Weights
Weight, approx. 300 g 240 g 240 g
■ Overview
• Digital outputs
• For connecting solenoid valves, contactors, low-power
motors, lamps and motor starters
■ Ordering data
SM 322 digital output modules Front connector
incl. labeling strips, bus connector 20-pin, with screw contacts
8 outputs, 24 V DC, 2 A 6ES7322-1BF01-0AA0 • 1 unit 6ES7392-1AJ00-0AA0
• 100 units 6ES7392-1AJ00-1AB0
16 outputs, 24 V DC, 0.5 A 6ES7322-1BH01-0AA0
20-pin, with spring-loaded contacts
16 outputs, 24 V DC, 0.5 A, 6ES7322-1BH10-0AA0 • 1 unit 6ES7392-1BJ00-0AA0
high speed
• 100 units 6ES7392-1BJ00-1AB0
32 outputs, 24 V DC, 0.5 A 6ES7322-1BL00-0AA0
40-pin, with screw contacts
64 outputs, 24 V DC, 0.3 A 6ES7322-1BP00-0AA0 • 1 unit 6ES7392-1AM00-0AA0
Note: • 100 units 6ES7392-1AM00-1AB0
6ES7392-4...0-0AA0 connection
cable and 6ES7392-1.N00-0AA0 40-pin, with spring-loaded contacts
terminal blocks necessary. • 1 unit 6ES7392-1BM01-0AA0
• 100 units 6ES7392-1BM01-1AB0
64 outputs, 24 V DC, 0.3 A, 6ES7322-1BP50-0AA0
sinking output S7-300 connecting cable
Note: For 64-channel modules; 2 units
6ES7392-4...0-0AA0 connection
cable and 6ES7392-1.N00-0AA0 1m 6ES7392-4BB00-0AA0
terminal blocks necessary.
2.5 m 6ES7392-4BC50-0AA0
8 outputs, 24 V DC, 0.5 A, 6ES7322-8BF00-0AB0
diagnostics-capable 5m 6ES7392-4BF00-0AA0
■ Technical specifications
Article number 6ES7322-1BH01- 6ES7322-1BH10- 6ES7322-1BL00- 6ES7322-1BP00- 6ES7322-1BP50- 6ES7322-8BF00-
0AA0 0AA0 0AA0 0AA0 0AA0 0AB0
SM322, 16DO 24V SM322 SM322, 32DO SM322 64DA, SM322 64DO, SM322, 8DO,
DC, 0,5A High Speed, 16DO 24V DC, 0,5A DC24V, 0,3A DC24V, 0.3A 24V DC, 0,5A
24V DC, 0.5A P-write M-write
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V 24 V 24 V 24 V
Input current
from load voltage L+ (without load), 80 mA 110 mA 160 mA 75 mA 75 mA 90 mA
max.
from backplane bus 5 V DC, max. 80 mA 70 mA 110 mA 100 mA 100 mA 70 mA
Power loss
Power loss, typ. 4.9 W 5W 6.6 W 6W 6W 5W
Digital outputs
Number of digital outputs 16 16 32 64 64 8
Short-circuit protection Yes; Electronic Yes; Electronic Yes; Electronic Yes; Electronic Yes; Electronic Yes; Electronic
Limitation of inductive shutdown L+ (-53 V) L+ (-53 V) L+ (-53 V) L+ (-53 V) M+ (45 V) L+ (-45 V)
voltage to
Switching capacity of the outputs
• on lamp load, max. 5W 5W 5W 5W 5W 5W
Load resistance range
• lower limit 48 Ω 48 Ω 48 Ω 80 Ω 80 Ω 48 Ω
• upper limit 4 kΩ 4 kΩ 4 kΩ 10 kΩ 10 kΩ 3 kΩ
Output voltage
• for signal "1", min. L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.5 V) M+ (0.5 V) L+ (-0.8 to -1.6 V)
Output current
• for signal "1" rated value 0.5 A 0.5 A 0.5 A 0.3 A 0.3 A 0.5 A
• for signal "0" residual current, max. 0.5 mA 0.5 mA 0.5 mA 0.1 mA 0.5 mA
■ Technical specifications
Article number 6ES7322-1BH01- 6ES7322-1BH10- 6ES7322-1BL00- 6ES7322-1BP00- 6ES7322-1BP50- 6ES7322-8BF00-
0AA0 0AA0 0AA0 0AA0 0AA0 0AB0
SM322, 16DO 24V SM322 SM322, 32DO SM322 64DA, SM322 64DO, SM322, 8DO,
DC, 0,5A High Speed, 16DO 24V DC, 0,5A DC24V, 0,3A DC24V, 0.3A 24V DC, 0,5A
24V DC, 0.5A P-write M-write
Switching frequency
• with resistive load, max. 100 Hz 1 000 Hz 100 Hz 100 Hz 100 Hz 100 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 2 Hz
• on lamp load, max. 10 Hz 10 Hz 10 Hz 10 Hz 10 Hz 10 Hz
Total current of the outputs
(per group)
5
horizontal installation
- up to 40 °C, max. 4A 4A 4A 1.6 A 1.6 A 4A
- up to 60 °C, max. 3A 3A 3A 1.2 A 1.2 A 3A
vertical installation
- up to 40 °C, max. 2A 2A 2A 1.6 A 1.6 A 4A
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m
Interrupts/diagnostics/
status information
Alarms No No No No No
Diagnostics function No No No No No Yes;
Parameterizable
Alarms
• Diagnostic alarm No No No No No Yes;
Parameterizable
Connection method
required front connector 20-pin 20-pin 40-pin Cable: Cable: 20-pin
6ES7392-4Bxx0- 6ES7392-4Bxx0-
0AA0 0AA0
terminal blocks: terminal blocks:
6ES7392-1xN00- 6ES7392-1xN00-
0AA0 0AA0
Dimensions
Width 40 mm 40 mm 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm 112 mm 112 mm 120 mm
Weights
Weight, approx. 190 g 200 g 260 g 230 g 230 g 210 g
■ Technical specifications
Article number 6ES7322-5GH00- 6ES7322-1CF00- 6ES7322-1BF01- 6ES7322-1FF01- 6ES7322-5FF00- 6ES7322-1FH00-
0AB0 0AA0 0AA0 0AA0 0AB0 0AA0
SM322, 16DO, SM322, 8DO, SM322, 8DO, SM322, 8DO, SM322, 8DO, SM322, 16DO,
AC/DC24-48V, 48-125V DC, 1,5A 24V DC, 2A 120/230V AC, 1A AC120/230V, 2A 120/230V AC, 1A
0,5A
Switching capacity of the outputs
• on lamp load, max. 2.5 W 15 W; 15 W (48 V) 10 W 50 W 50 W 50 W
or 40 W (125 V)
Load resistance range
• lower limit 12 Ω
• upper limit 4 kΩ
5
Output voltage
• for signal "1", min. L+ (-0.25 V) L+ (-1.2 V) L+ (-0.8 V) L1 (-1.5 V) L1 (-8.5 V)
Output current
• for signal "1" rated value 0.5 A 1.5 A 2A 2A 2A 1A
• for signal "0" residual current, max. 10 µA 0.5 mA 0.5 mA 2 mA 2 mA 2 mA
Switching frequency
• with resistive load, max. 10 Hz 25 Hz 100 Hz 10 Hz 10 Hz 10 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz
• on lamp load, max. 0.5 Hz 10 Hz 10 Hz 1 Hz 1 Hz 1 Hz
Total current of the outputs
(per group)
horizontal installation
- up to 40 °C, max. 0.5 A; 8 A per 6A 4A 4A 8A 4A
module
- up to 50 °C, max. 4A
- up to 60 °C, max. 0.5 A; 8 A per 3A 4A 2A 4A 2A
module
vertical installation
- up to 40 °C, max. 0.5 A; 8 A per 4A 4A 2A 4A 2A
module
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m
Interrupts/diagnostics/
status information
Alarms No No No
Diagnostics function Yes; No No Yes; Fuse blown Yes; Yes; Fuse blown
Parameterizable or load voltage Parameterizable or load voltage
missing missing
Alarms
• Diagnostic alarm Yes; No No No Yes; No
Parameterizable Parameterizable
Connection method
required front connector 40-pin 20-pin 20-pin 20-pin 40-pin 20-pin
Dimensions
Width 40 mm 40 mm 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm 120 mm 120 mm 120 mm
Weights
Weight, approx. 260 g 250 g 190 g 275 g 275 g 275 g
■ Technical specifications
Article number 6ES7322-1FL00-0AA0 6ES7322-1HF01-0AA0 6ES7322-1HF10-0AA0 6ES7322-5HF00-0AB0 6ES7322-1HH01-0AA0
SM322, 32DO, SM322, 8DA, SM322, 8DA, SM322, 8DO Relay, SM322, 16DO Relay
120/230V AC, 1A 24V DC/2A or 24V DC/5A OR 24VDC, 120-230V AC,
230V AC/2A 230V AC/5A 5A
Power loss
Power loss, typ. 25 W 3.2 W 3.2 W 3.5 W 4.5 W
Digital outputs
Number of digital outputs 32 8; Relays 8; Relays 8; Relays 16; Relays
Short-circuit protection No No No; to be provided No; to be provided No
externally externally
Switching capacity of the outputs
• on lamp load, max.
Output voltage
50 W 50 W 1 500 W; 230 V AC 1 500 W; 230 V AC 50 W; 230 V AC
5
• for signal "1", min. L1 (-0.8 V)
Output current
• for signal "1" rated value 1A 2A 5A 5A 2A
• for signal "0" residual current, max. 2 mA
Switching frequency
• with resistive load, max. 10 Hz 2 Hz 2 Hz 2 Hz 1 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz
• on lamp load, max. 1 Hz 2 Hz 2 Hz 2 Hz 1 Hz
• mechanical, max. 10 Hz 10 Hz 10 Hz 10 Hz
Total current of the outputs
(per group)
horizontal installation
- up to 40 °C, max. 4A
- up to 60 °C, max. 3A 5A 5A 8A
vertical installation
- up to 40 °C, max. 4A 5A 5A 8A
Relay outputs
• Rated supply voltage of relay coil L+ 24 V; 110 mA 24 V 24 V
(DC)
• Contact connection (internal) Yes; No Yes; 330 Ohm, 0.1uF No
SIOV-CU4032 K275G
• Number of operating cycles, max. 300 000; 230 V AC: 300 000; 300 000 100 000; 100 000 100 000; 50 000
100 000; 120 V AC: (24 V DC, at 2 A); (24 V DC, at 5 A), (24 V DC, at 2 A);
200 000; 24 V DC: 200 000 (120 V AC, 100 000 (230 V AC, 700 000 (120 V AC,
300 000 (at 2 A) at 3 A); 100 000 at 5 A) at 2 A); 100 000
(230 V AC, at 3 A) (230 V AC, at 2 A)
Switching capacity of contacts
- with inductive load, max. 2 A; 2 A (230 V AC), 3 A; 3 A (230 V DC), 5 A; 5 A (230 V DC), 2 A; 2 A (230 V AC),
2 A (24 V DC) 2 A (24 V AC) 5 A (24 V AC) 2 A (24 V DC)
- with resistive load, max. 2A 8 A; 8 A (230 V DC), 5 A; 5 A (230 V DC), 2 A; 2 A (230 V AC),
5 A (24 V AC) 5 A (24 V AC) 2 A (24 V DC)
- Thermal continuous current, max. 3A 8A 5A 2A
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m
Interrupts/diagnostics/
status information
Alarms No No No Yes No
Diagnostics function Yes; Fuse blown or No No Yes; Parameterizable No
load voltage missing
Alarms
• Diagnostic alarm No No No Yes; Parameterizable No
Connection method
required front connector 20-pin 20-pin 40-pin 40-pin 20-pin
Dimensions
Width 80 mm 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 117 mm 120 mm 120 mm 120 mm 120 mm
Weights
Weight, approx. 500 g 190 g 320 g 320 g 250 g
■ Overview
• Digital inputs and outputs
• For connection of switches, 2-wire proximity switches
(BEROs), solenoid valves, contactors, low-power motors,
lamps and motor starters
■ Technical specifications
Article number 6ES7323-1BH01-0AA0 6ES7323-1BL00-0AA0 6ES7327-1BH00-0AB0
SM323, 8DI/8DO, DC24V, 0,5A SM323, 16DI/DO, DC24V, 0,5A SM327, 8DI/8DX, DC24V, 0,5A
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V
Input current
from load voltage L+ (without load), 40 mA 80 mA 20 mA
max.
from backplane bus 5 V DC, max. 40 mA 80 mA 60 mA
Power loss
Power loss, typ. 3.5 W 6.5 W 3W
Digital inputs 5
Number of digital inputs 8 16 8; 8 hard-wired, 8 others individually
parameterizable
Input characteristic curve Yes Yes Yes
in accordance with IEC 61131, type 1
Input voltage
• Type of input voltage DC DC DC
• Rated value (DC) 24 V 24 V 24 V
• for signal "0" -30 to +5 V -30 to +5 V -30 to +5 V
• for signal "1" 13 to 30V 13 to 30V +15 to +30 V
Input current
• for signal "1", typ. 7 mA 7 mA 6 mA
Input delay
(for rated value of input voltage)
for standard inputs
- at "0" to "1", min. 1.2 ms 1.2 ms 1.2 ms
- at "0" to "1", max. 4.8 ms 4.8 ms 4.8 ms
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m
Digital outputs
Number of digital outputs 8 16 8; can also be parameterized
individually as DI
Short-circuit protection Yes Yes Yes
Limitation of inductive shutdown L+ (-53 V) L+ (-48 V) L+ (-54 V)
voltage to
Switching capacity of the outputs
• on lamp load, max. 5W 5W 5W
Load resistance range
• lower limit 48 Ω 48 Ω 48 Ω
• upper limit 4 kΩ 4 kΩ 4 kΩ
Output voltage
• for signal "1", min. L+ (-0.8 V) L+ (-0.8 V) L+ (-1.5 V)
Output current
• for signal "1" rated value 0.5 A 0.5 A 0.5 A
• for signal "0" residual current, max. 0.5 mA 0.5 mA 0.5 mA
Switching frequency
• with resistive load, max. 100 Hz 100 Hz 100 Hz
• with inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz
• on lamp load, max. 10 Hz 100 Hz 10 Hz
Total current of the outputs
(per group)
horizontal installation
- up to 40 °C, max. 4A 4A 4A
- up to 60 °C, max. 4A 3A 3A
vertical installation
- up to 40 °C, max. 4A 2A 2A
Cable length
• shielded, max. 1 000 m 1 000 m 1 000 m
■ Technical specifications
Article number 6ES7323-1BH01-0AA0 6ES7323-1BL00-0AA0 6ES7327-1BH00-0AB0
SM323, 8DI/8DO, DC24V, 0,5A SM323, 16DI/DO, DC24V, 0,5A SM327, 8DI/8DX, DC24V, 0,5A
Encoder
Connectable encoders
• 2-wire sensor Yes Yes Yes
- permissible quiescent current 2 mA 1.5 mA 1.5 mA
(2-wire sensor), max.
Interrupts/diagnostics/
status information
Alarms No No No
Diagnostics function No No No
5 Connection method
required front connector 20-pin 40-pin 20-pin
Dimensions
Width 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm
Weights
Weight, approx. 220 g 260 g 200 g
■ Overview
• Digital inputs
• For connection of switches and 2-wire proximity switches
(BEROs)
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1321-1BH02-2AA0 6AG1321-1BL00-2AA0 6AG1321-1CH20-2AA0 6AG1321-1FF01-2AA0 6AG1321-1FF10-7AA0
Based on 6ES7321-1BH02-0AA0 6ES7321-1BL00-0AA0 6ES7321-1CH20-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF10-0AA0
SIPLUS SM321 SIPLUS SM321 SIPLUS SM 321 16DE/ SIPLUS S7-300 SM321 SIPLUS S7-300 SM321
16DE/24VDC 32DE/24VDC DC 48-125 V 8DE/120/230VAC 8 DI
Ambient conditions
Ambient temperature
during operation
• min. -40 °C; = Tmin -40 °C; = Tmin -25 °C; = Tmin -40 °C; = Tmin -25 °C
• max. 70 °C; = Tmax; 70 °C; = Tmax; for use 70 °C; = Tmax; for use 70 °C; = Tmax; for use 70 °C; = Tmax;
60 °C @ UL/cUL, ATEX on railway vehicles on railway vehicles on railway vehicles 60 °C @ UL/cUL, ATEX
and FM use according to EN50155, according to EN50155, according to EN50155, and FM use
the rated temperature the rated temperature the rated temperature
5 range -25 ... +55 °C
(T1) or 60 °C @
range -25 ... +55 °C
(T1) or 60 °C @
range -25 ... +55 °C
(T1) or 60 °C @
UL/ULhaz/ATEX/FM UL/ULhaz/ATEX/FM UL/ULhaz/ATEX/FM
use applies use applies use applies
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 2 000 m 2 000 m 5 000 m
max.
• Ambient air temperature-barometric Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
// // //
Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K) Tmin ... (Tmax - 10 K)
at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) (+2 000 m ... +3 500 m) (+2 000 m ... +3 500 m)
// // //
Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K) Tmin ... (Tmax -20 K)
at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold, Yes; Class 3B2 mold,
according to EN 60721-3-3 fungus and dry rot fungus and dry rot fungus and dry rot fungus and dry rot fungus and dry rot
spores (with the spores (with the spores (with the spores (with the spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4 Yes; Class 3C4
according to EN 60721-3-3 (RH < 75 %) (RH < 75 %) (RH < 75 %) (RH < 75 %) (RH < 75 %)
incl. salt spray incl. salt spray incl. salt spray incl. salt spray incl. salt spray
acc. to EN 60068-2-52 acc. to EN 60068-2-52 acc. to EN 60068-2-52 acc. to EN 60068-2-52 acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl. Yes; Class 3S4 incl.
according to EN 60721-3-3 sand, dust, * sand, dust, * sand, dust, * sand, dust, * sand, dust, *
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, Yes; Class 5B2 mold, Yes; Class 5B2 mold,
according to EN 60721-3-5 fungus and dry rot fungus and dry rot fungus and dry rot
spores (with the spores (with the spores (with the
exception of fauna); exception of fauna); exception of fauna);
Class 5B3 on request Class 5B3 on request Class 5B3 on request
- to chemically active substances Yes; Class 5C3 Yes; Class 5C3 Yes; Class 5C3
according to EN 60721-3-5 (RH < 75 %) (RH < 75 %) (RH < 75 %)
incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 50155 (ST2); * EN 50155 (ST2); * EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. Yes; Class 5S3 incl. Yes; Class 5S3 incl.
according to EN 60721-3-5 sand, dust; * sand, dust; * sand, dust; *
■ Technical specifications
Article number 6AG1321-1BH02-2AA0 6AG1321-1BL00-2AA0 6AG1321-1CH20-2AA0 6AG1321-1FF01-2AA0 6AG1321-1FF10-7AA0
Based on 6ES7321-1BH02-0AA0 6ES7321-1BL00-0AA0 6ES7321-1CH20-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF10-0AA0
SIPLUS SM321 SIPLUS SM321 SIPLUS SM 321 16DE/ SIPLUS S7-300 SM321 SIPLUS S7-300 SM321
16DE/24VDC 32DE/24VDC DC 48-125 V 8DE/120/230VAC 8 DI
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold Yes; Class 6B2 mold
according to EN 60721-3-6 and fungal spores and fungal spores and fungal spores and fungal spores and fungal spores
(excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna); (excluding fauna);
Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3 Yes; Class 6C3
according to EN 60721-3-6 (RH < 75 %) (RH < 75 %) (RH < 75 %) (RH < 75 %) (RH < 75 %)
incl. salt spray incl. salt spray incl. salt spray incl. salt spray incl. salt spray
acc. to EN 60068-2-52
(severity degree 3); *
acc. to EN 60068-2-52
(severity degree 3); *
acc. to EN 60068-2-52
(severity degree 3); *
acc. to EN 60068-2-52
(severity degree 3); *
acc. to EN 60068-2-52
(severity degree 3); * 5
- to mechanically active substances Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl. Yes; Class 6S3 incl.
according to EN 60721-3-6 sand, dust; * sand, dust; * sand, dust; * sand, dust; * sand, dust; *
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding (excluding (excluding (excluding (excluding
trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene) trichlorethylene)
- Environmental conditions for Yes; Level GX Yes; Level GX Yes; Level GX Yes; Level GX Yes; Level GX
process, measuring and control group A/B (excluding group A/B (excluding group A/B (excluding group A/B (excluding group A/B (excluding
systems acc. to ANSI/ISA-71.04 trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene; trichlorethylene;
harmful gas harmful gas harmful gas harmful gas harmful gas
concentrations concentrations concentrations concentrations concentrations
up to the limits of up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 EN 60721-3-3 EN 60721-3-3 EN 60721-3-3 EN 60721-3-3 class
class 3C4 class 3C4 class 3C4 class 3C4 3C4 permissible);
permissible); permissible); permissible); permissible); level LC3 (salt spray)
level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) level LC3 (salt spray) and level LB3 (oil)
and level LB3 (oil) and level LB3 (oil) and level LB3 (oil) and level LB3 (oil)
Remark
- Note regarding classification * The supplied plug * The supplied plug * The supplied plug * The supplied plug * The supplied plug
of environmental conditions covers must remain in covers must remain in covers must remain in covers must remain in covers must remain in
acc. to EN 60721, EN 60654-4 place over the unused place over the unused place over the unused place over the unused place over the unused
and ANSI/ISA-71.04 interfaces during interfaces during interfaces during interfaces during interfaces during
operation! operation! operation! operation! operation!
■ Technical specifications
Article number 6AG1321-1FH00-7AA0 6AG1321-7BH01-2AB0 6AG1321-7TH00-4AB0
Based on 6ES7321-1FH00-0AA0 6ES7321-7BH01-0AB0 6ES7321-7TH00-0AB0
SIPLUS S7-300 SM321 16DI SIPLUS SM321 16DE/24VDC SIPLUS PCS 7 SM321 16DE
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
5
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus and dry
according to EN 60721-3-5 rot spores (with the exception of
fauna); Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %) incl. salt
according to EN 60721-3-5 spray acc. to EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand, dust; *
according to EN 60721-3-5
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
of environmental conditions remain in place over the unused remain in place over the unused remain in place over the unused
acc. to EN 60721, EN 60654-4 interfaces during operation! interfaces during operation! interfaces during operation!
and ANSI/ISA-71.04
■ Overview
• Digital outputs
• For connecting solenoid valves, contactors,
small-power motors, lamps and motor starters
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1322-1BF01-2XB0 6AG1322-8BF00-2AB0 6AG1322-1BH01-2AA0 6AG1322-1BL00-2AA0
Based on 6ES7322-1BF01-0XB0 6ES7322-8BF00-0AB0 6ES7322-1BH01-0AA0 6ES7322-1BL00-0AA0
SIPLUS S7-300 SM322 SIPLUS SM322 8DA/24VDC SIPLUS S7-300 SM322 SIPLUS S7-300 SM322
16DA/24VDC 0.5A 32DO/24VDC 0.5A
Ambient conditions
Ambient temperature
during operation
• min. -25 °C -25 °C; = Tmin -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 70 °C; = Tmax; 70 °C; = Tmax; for use on 70 °C; = Tmax; for use on
60 °C @ UL/cUL use 60 °C @ UL/cUL use railway vehicles according to railway vehicles according to
EN50155, the rated tempera- EN50155, the rated tempera-
ture range -25 ... +55 °C (T1) ture range -25 ... +55 °C (T1)
5 or 60 °C @
UL/ULhaz/ATEX/FM use
or 60 °C @
UL/ULhaz/ATEX/FM use
applies applies
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus Yes; Class 5B2 mold, fungus Yes; Class 5B2 mold, fungus
according to EN 60721-3-5 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna);
Class 5B3 on request Class 5B3 on request Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %) Yes; Class 5C3 (RH < 75 %) Yes; Class 5C3 (RH < 75 %)
according to EN 60721-3-5 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 50155 (ST2); * EN 50155 (ST2); * EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand, Yes; Class 5S3 incl. sand, Yes; Class 5S3 incl. sand,
according to EN 60721-3-5 dust; * dust; * dust; *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1322-1BF01-2XB0 6AG1322-8BF00-2AB0 6AG1322-1BH01-2AA0 6AG1322-1BL00-2AA0
Based on 6ES7322-1BF01-0XB0 6ES7322-8BF00-0AB0 6ES7322-1BH01-0AA0 6ES7322-1BL00-0AA0
SIPLUS S7-300 SM322 SIPLUS SM322 8DA/24VDC SIPLUS S7-300 SM322 SIPLUS S7-300 SM322
16DA/24VDC 0.5A 32DO/24VDC 0.5A
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
5
Remark
- Note regarding classification * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
of environmental conditions must remain in place over must remain in place over must remain in place over must remain in place over
acc. to EN 60721, EN 60654-4 the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
and ANSI/ISA-71.04 operation! operation! operation! operation!
■ Technical specifications
Article number 6AG1322-1CF00-7AA0 6AG1322-1HF10-2AA0 6AG1322-5HF00-4AB0 6AG1322-1FF01-7AA0
Based on 6ES7322-1CF00-0AA0 6ES7322-1HF10-0AA0 6ES7322-5HF00-0AB0 6ES7322-1FF01-0AA0
SIPLUS SM322 SIPLUS SM322 SIPLUS_SM322_8RO SIPLUS S7-300 SM322
8DA/48-125VDC 8DA - Relais 8DA/120/230VAC
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
■ Technical specifications
Article number 6AG1322-5FF00-4AB0 6AG1322-1FH00-7AA0 6AG1322-1HH01-2AA0
Based on 6ES7322-5FF00-0AB0 6ES7322-1FH00-0AA0 6ES7322-1HH01-0AA0
SIPLUS S7-300 SM322 8DO SIPLUS S7-300 SM322 16DO SIPLUS SM322
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
5
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus and dry
according to EN 60721-3-5 rot spores (with the exception of
fauna); Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %) incl. salt
according to EN 60721-3-5 spray acc. to EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand, dust; *
according to EN 60721-3-5
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt Yes; Class 6C3 (RH < 75 %) incl. salt
according to EN 60721-3-6 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52 spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 (
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
of environmental conditions remain in place over the unused remain in place over the unused remain in place over the unused
acc. to EN 60721, EN 60654-4 interfaces during operation! interfaces during operation! interfaces during operation!
and ANSI/ISA-71.04
■ Overview
• Digital inputs and outputs
• For connection of switches, 2-wire proximity switches
(BEROs), solenoid valves, contactors, low-power motors,
lamps and motor starters
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1323-1BH01-2AA0 Article number 6AG1323-1BH01-2AA0
Based on 6ES7323-1BH01-0AA0 Based on 6ES7323-1BH01-0AA0
SIPLUS SM323 8DE/8DA SIPLUS SM323 8DE/8DA
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold and fungal
during operation according to EN 60721-3-6 spores (excluding fauna); Class 6B3
• min. -40 °C; = Tmin on request
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, - to chemically active substances Yes; Class 6C3 (RH < 75 %)
ATEX and FM use according to EN 60721-3-6 incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
Altitude during operation
relating to sea level - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
• Installation altitude above sea level, 5 000 m
max. Usage in industrial process
technology
5
• Ambient air temperature- Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa - Against chemically active Yes; Class 3 (excluding trichloreth-
(-1 000 m ... +2 000 m) // substances acc. to EN 60654-4 ylene)
Tmin ... (Tmax - 10 K) at - Environmental conditions for Yes; Level GX group A/B
795 hPa ... 658 hPa process, measuring and control (excluding trichlorethylene; harmful
(+2 000 m ... +3 500 m) // systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of
Tmin ... (Tmax -20 K) at EN 60721-3-3 class 3C4
658 hPa ... 540 hPa permissible); level LC3 (salt spray)
(+3 500 m ... +5 000 m) and level LB3 (oil)
Resistance Remark
Use in stationary industrial systems - Note regarding classification * The supplied plug covers must
- to biologically active substances Yes; Class 3B2 mold, fungus and of environmental conditions remain in place over the unused
according to EN 60721-3-3 dry rot spores (with the exception of acc. to EN 60721, EN 60654-4 interfaces during operation!
fauna); Class 3B3 on request and ANSI/ISA-71.04
- to chemically active substances Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus and dry
according to EN 60721-3-5 rot spores (with the exception of
fauna); Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %) incl. salt
according to EN 60721-3-5 spray acc. to EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand, dust; *
according to EN 60721-3-5
■ Overview
• Analog inputs
• For connection of voltage and current sensors,
thermocouples, resistors and resistance thermometers
8 inputs, for thermal resistors 6ES7331-7PF01-0AB0 10 units (spare part), for modules
with 20-pin front connector
8 inputs, for thermoelements 6ES7331-7PF11-0AB0
Labeling strips 6ES7392-2XX00-0AA0
Measuring range module 6ES7974-0AA00-0AA0
for analog inputs 10 units (spare part), for modules
with 20-pin front connector
1 module for 2 analog inputs;
2 units (spare part) Labeling sheets
for machine labeling
Front connector
For modules with 20-pin front
20-pin, with screw contacts connector, DIN A4, for printing
• 1 unit 6ES7392-1AJ00-0AA0 with laser printer; 10 units
• 100 units 6ES7392-1AJ00-1AB0 Petrol 6ES7392-2AX00-0AA0
20-pin, with spring-loaded contacts Light beige 6ES7392-2BX00-0AA0
• 1 unit 6ES7392-1BJ00-0AA0
Yellow 6ES7392-2CX00-0AA0
• 100 units 6ES7392-1BJ00-1AB0
Red 6ES7392-2DX00-0AA0
40-pin, with screw contacts
• 1 unit 6ES7392-1AM00-0AA0 For modules with 40-pin front
• 100 units 6ES7392-1AM00-1AB0 connector, DIN A4, for printing
with laser printer; 10 units
40-pin, with spring-loaded contacts
Petrol 6ES7392-2AX10-0AA0
• 1 unit 6ES7392-1BM01-0AA0
• 100 units 6ES7392-1BM01-1AB0 Light beige 6ES7392-2BX10-0AA0
5
■ Technical specifications
Article number 6ES7331-7KF02-0AB0 6ES7331-7HF01-0AB0 6ES7331-1KF02-0AB0 6ES7331-7KB02-0AB0
SM331, 8AI, 9/12/14Bit SM331, 8AI, 14BIT, SM331, 8AI, 13bit SM331, 2AI, 9/12/14Bit
0,052MS/channel
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V
Input current
from load voltage L+ (without load), 30 mA 50 mA 30 mA
max.
from backplane bus 5 V DC, max. 50 mA 100 mA 90 mA 50 mA
Power loss
Power loss, typ. 1W 1.5 W 0.4 W 1W
Analog inputs
Number of analog inputs 8 8 8 2
• For resistance measurement 4 8 1
permissible input voltage for voltage 20 V; continuous; 20 V; 20 V DC permanent, 30 V; 12 V continuous, 20 V; continuous;
input (destruction limit), max. 75 V for max. 1 s 75 V DC for max. 1 s 30 V for max. 1 s 75 V for max. 1 s
(mark to space ratio 1:20) (duty factor 1:20) (mark to space ratio 1:20)
permissible input current for current 40 mA 40 mA 40 mA 40 mA
input (destruction limit), max.
Input ranges (rated values), voltages
• 0 to +10 V No No Yes No
• 1 V to 5 V Yes Yes Yes Yes
• 1 V to 10 V No No No
• -1 V to +1 V Yes Yes Yes Yes
• -10 V to +10 V Yes Yes Yes Yes
• -2.5 V to +2.5 V Yes No Yes
• -250 mV to +250 mV Yes No Yes
• -5 V to +5 V Yes Yes Yes Yes
• -50 mV to +50 mV No Yes No
• -500 mV to +500 mV Yes Yes Yes Yes
• -80 mV to +80 mV Yes Yes No Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes Yes Yes Yes
• -10 mA to +10 mA Yes No Yes
• -20 mA to +20 mA Yes Yes Yes Yes
• -3.2 mA to +3.2 mA Yes No Yes
• 4 mA to 20 mA Yes Yes Yes Yes
■ Technical specifications
Article number 6ES7331-7KF02-0AB0 6ES7331-7HF01-0AB0 6ES7331-1KF02-0AB0 6ES7331-7KB02-0AB0
SM331, 8AI, 9/12/14Bit SM331, 8AI, 14BIT, SM331, 8AI, 13bit SM331, 2AI, 9/12/14Bit
0,052MS/channel
Input ranges (rated values),
thermocouples
• Type B No No No
• Type C No No
• Type E Yes No Yes
• Type J Yes No Yes
• Type K Yes No Yes
• Type L Yes No No
5 • Type N
• Type R
Yes
No
No
No
Yes
No
• Type S No No No
• Type T No No No
• Type U No No No
• Type TXK/TXK(L) to GOST No No No
Input ranges (rated values),
resistance thermometer
• Cu 10 No No No
• Ni 100 Yes; Standard Yes; Standard/climate Yes
• Ni 1000 No Yes No
• LG-Ni 1000 No Yes; Standard/climate No
• Ni 120 No No No
• Ni 200 No No No
• Ni 500 No No No
• Pt 100 Yes; Standard Yes; Standard/climate Yes
• Pt 1000 No No No
• Pt 200 No No No
• Pt 500 No No No
Input ranges (rated values),
resistors
• 0 to 150 ohms Yes No Yes
• 0 to 300 ohms Yes No Yes
• 0 to 600 ohms Yes Yes Yes
• 0 to 6000 ohms No Yes No
Thermocouple (TC)
Temperature compensation
- parameterizable Yes No Yes
- internal temperature Yes No Yes
compensation
- external temperature Yes No Yes
compensation with
compensations socket
- for definable comparison point Yes Yes
temperature
Characteristic linearization
• parameterizable Yes Yes Yes
- for thermocouples Type E, J, K, L, N No Type E, J, K, L, N
- for resistance thermometer Pt100 (standard, yes; Pt100 standard/air con.; Pt100 (standard, climatic
climatic range), Ni100 Ni100 standard/air con.; range), Ni100 (standard,
(standard, climatic range) Ni1000 standard/air con.; climatic range)
LG-Ni1000 standard/air con.
Cable length
• shielded, max. 200 m; 50 m at 80 mV and 200 m 200 m; max. 50 m at 50 mV 200 m; 50 m at 80 mV and
thermocouples thermocouples
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 15 bit; Unipolar: 14 bit; Unipolar: 14 bit; 13 bit 15 bit; Unipolar:
(bit including sign), max. 9/12/12/14 bit; bipolar: bipolar: 13 bit + sign 9/12/12/14 bit; bipolar:
9 bit + sign/12 bit + sign/ 9 bit + sign/12 bit + sign/
12 bit + sign/14 bit + sign 12 bit + sign/14 bit + sign
• Integration time, parameterizable Yes Yes Yes Yes
• Basic conversion time (ms) 52 µs per channel
■ Technical specifications
Article number 6ES7331-7KF02-0AB0 6ES7331-7HF01-0AB0 6ES7331-1KF02-0AB0 6ES7331-7KB02-0AB0
SM331, 8AI, 9/12/14Bit SM331, 8AI, 14BIT, SM331, 8AI, 13bit SM331, 2AI, 9/12/14Bit
0,052MS/channel
Analog value generation
for the inputs (continued)
• Interference voltage suppression 400 / 60 / 50 / 10 Hz none / 400 / 60 / 50 Hz 400 / 60 / 50 / 10 Hz
for interference frequency f1 in Hz
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes Yes
• for current measurement as 2-wire Yes Yes Yes; with external supply Yes
5
transducer
• for current measurement as 4-wire Yes Yes Yes Yes
transducer
• for resistance measurement with Yes Yes Yes
two-wire connection
• for resistance measurement with Yes Yes Yes
three-wire connection
• for resistance measurement with Yes Yes Yes
four-wire connection
Errors/accuracies
Operational error limit in overall
temperature range
• Voltage, relative to input range, (+/-) 1 %; ±1% (80 mV); ±0.6% 0.4 % 0.6 %; ±0.6 % (±5 V, 10 V, 1 %; ±1% (80 mV); ±0.6%
(250 mV to 1 000 mV); 1 to 5 V, 0 to 10 V); ±0.5 % (250 mV to 1 000 mV);
±0.8% (2.5 V to 10 V) (±50 mV, 500 mV, 1 V) ±0.8% (2.5 V to 10 V)
• Current, relative to input range, (+/-) 0.7 %; From 3.2 to 20 mA 0.3 % 0.5 %; ±20 mA, 0 to 20 mA, 0.7 %; From 3.2 to 20 mA
4 to 20 mA
• Resistance, relative to input range, 0.7 %; 150, 300, 600 Ohm 0.5 %; 0 to 6 kohms, 0 to 600 0.7 %; 150, 300, 600 Ohm
(+/-) kohms
• Resistance thermometer, 0.7 %; 1 Kelvin (Pt100, Ni100, 0.7 %;
relative to input range, (+/-) ±0.7 % (Pt100/ Ni100); climatic; Ni1000, LG-Ni1000, ±0.7 % (Pt100/ Ni100);
±0.8 % (Pt100 climate) standard; Ni1000, ±0.8 % (Pt100 climate)
LG-Ni1000, climatic);
1.2 Kelvin (Pt100, Ni100,
standard)
• Thermocouple, relative to input 1.1 %; Type E, J, K, L, N 1.1 %; Type E, J, K, L, N
range, (+/-)
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input range, (+/-) 0.6 %; ±0.4 % (250 mV to 0.25 % 0.4 %; 0.4% (±5 V, 10 V, 0.6 %;
1 000 mV); ±0.6 % (2.5 mV 1 to 5 V, 0 to 10 V); 0.3% ±0.6% (80 mV, 2.5 V to 10 V);
to 10 mV); ±0.7 % (80 mV) (±50 mV, 500 mV, 1 V) ±0.4% (250 mV to 1 000 mV)
• Current, relative to input range, (+/-) 0.5 %; 3.2 to 20 mA 0.2 % 0.3 %; ±20 mA, 0 to 20 mA, 0.5 %; 3.2 to 20 mA
4 to 20 mA
• Resistance, relative to input range, 0.5 %; 150, 300, 600 Ohm 0.3 %; 0 to 6 kohms, 0.5 %; 150, 300, 600 Ohm
(+/-) 0 to 600 kohms
• Resistance thermometer, 0.6 %; ±0.5% (Pt100/ Ni100), 1 Kelvin (Pt100, Ni100, 0.6 %; ±0.5% (Pt100/ Ni100),
relative to input range, (+/-) ±0.6% (Pt100 climate) standard); 0.8 Kelvin (Pt100, ±0.6% (Pt100 climate)
Ni100, climatic; Ni1000,
LG-Ni1000, standard;
Ni1000, LG-Ni1000, climatic)
• Thermocouple, relative to input 0.7 %; Type E, N, J, K, L 0.7 %; Type E, N, J, K, L
range, (+/-)
Interrupts/diagnostics/
status information
Diagnostics function Yes; Parameterizable Yes No Yes; Parameterizable
Alarms
• Diagnostic alarm Yes; Parameterizable, Yes; Parameterizable No Yes
channels 0 and 2
• Limit value alarm Yes; Parameterizable Yes; Parameterizable, No Yes; Parameterizable,
channels 0 and 2 channel 0
Connection method
required front connector 20-pin 20-pin 40-pin 20-pin
Dimensions
Width 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm
Depth 117 mm 117 mm 117 mm 120 mm
Weights
Weight, approx. 250 g 230 g 250 g 250 g
■ Technical specifications
Article number 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0 6ES7331-7PE10-0AB0 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0
SM331, 8AI, resistor, SM331, 8AI, 16BIT, SM331, 6AI, 16bit, SM331,8AI,+/-5/10V, SM331,8AI,+/-5/10V,
PT100/200/1000, . Thermocouples Thermocouple 1-5V,+/-20mA, 1-5V,+/-20mA,
0/4-20mA 0/4-20mA
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V 24 V
Input current
from load voltage L+ (without load), 240 mA 240 mA 150 mA 200 mA
max.
from backplane bus 5 V DC, max. 100 mA 100 mA 100 mA 130 mA 100 mA
5 Power loss
Power loss, typ. 4.6 W 3W 2.2 W 0.6 W 3W
Analog inputs
Number of analog inputs 8 8 6 8 8
• For resistance measurement 8
permissible input voltage for voltage 75 V; 35 V continuous, 75 V; 35 V; 35 V continuous, 50 V; Permanent 75 V; 35 V continuous,
input (destruction limit), max. 75 V for max. 1 s (mark 20 V DC permanent, 75 V for max. 1 s (mark 75 V for max. 1 s (mark
to space ratio 1:20) 75 V DC for max. 1 s to space ratio 1:20) to space ratio 1:20)
(duty factor 1:20)
permissible input current for current 32 mA 40 mA
input (destruction limit), max.
Input ranges (rated values),
voltages
• 0 to +10 V No No No No No
• 1 V to 5 V No No No Yes Yes
• 1 V to 10 V No No No No No
• -1 V to +1 V No No Yes No No
• -10 V to +10 V No No No Yes Yes
• -2.5 V to +2.5 V No No No No No
• -250 mV to +250 mV No No Yes No No
• -5 V to +5 V No No No Yes Yes
• -50 mV to +50 mV No No Yes No No
• -500 mV to +500 mV No No Yes No No
• -80 mV to +80 mV No No Yes No No
Input ranges (rated values), currents
• 0 to 20 mA No No No Yes Yes
• -10 mA to +10 mA No No No No No
• -20 mA to +20 mA No No No Yes Yes
• -3.2 mA to +3.2 mA No No No No No
• 4 mA to 20 mA No No No Yes Yes
Input ranges (rated values),
thermocouples
• Type B No Yes Yes No No
• Type C No Yes Yes No No
• Type E No Yes Yes No No
• Type J No Yes Yes No No
• Type K No Yes Yes No No
• Type L No Yes Yes No No
• Type N No Yes Yes No No
• Type R No Yes Yes No No
• Type S No Yes Yes No No
• Type T No Yes Yes No No
• Type U No Yes Yes No No
• Type TXK/TXK(L) to GOST No Yes Yes No No
■ Technical specifications
Article number 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0 6ES7331-7PE10-0AB0 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0
SM331, 8AI, resistor, SM331, 8AI, 16BIT, SM331, 6AI, 16bit, SM331,8AI,+/-5/10V, SM331,8AI,+/-5/10V,
PT100/200/1000, . Thermocouples Thermocouple 1-5V,+/-20mA, 1-5V,+/-20mA,
0/4-20mA 0/4-20mA
Input ranges (rated values),
resistance thermometer
• Cu 10 Yes No No No No
• Ni 100 Yes No No No No
• Ni 1000 Yes No No No No
• LG-Ni 1000 Yes No No No No
• Ni 120 Yes No No No No
• Ni 200
• Ni 500
Yes
Yes
No
No
No
No
No
No
No
No
5
• Pt 100 Yes No No No No
• Pt 1000 Yes No No No No
• Pt 200 Yes No No No No
• Pt 500 Yes No No No No
Input ranges (rated values),
resistors
• 0 to 150 ohms Yes No No No No
• 0 to 300 ohms Yes No No No No
• 0 to 600 ohms Yes No No No No
• 0 to 6000 ohms No No No No
Thermocouple (TC)
Temperature compensation
- parameterizable Yes Yes
- internal temperature Yes Yes
compensation
- external temperature Yes Yes
compensation with Pt100
- external temperature Yes Yes
compensation with compensations
socket
- for definable comparison point Yes Yes
temperature
Characteristic linearization
• parameterizable Yes Yes Yes
- for thermocouples Type B, E, J, K, L, N, R, Type B, E, J, K, L, N, R,
S. T, U, C S. T, U, C, TXK, XK(L)
- for resistance thermometer Pt100, Pt200, Pt500, No
Pt1000, Ni100, Ni120,
Ni200, Ni500, Ni1000,
Cu10;
(standard/climate)
Cable length
• shielded, max. 200 m 100 m 200 m 200 m 200 m
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 16 bit; 16 bit; 16 bit; 16 bit; Unipolar: 16 bit; Unipolar:
(bit including sign), max. Two's complement Two's complement Two's complement 15/15/15/15 bit; 15/15/15/15 bit;
bipolar: 15 bit + sign/ bipolar: 15 bit + sign/
15 bit + sign/15 bit 15 bit + sign/15 bit
+ sign/15 bit + sign + sign/15 bit + sign
• Integration time, parameterizable Yes Yes Yes Yes; 10/ 16.67/ 20/ 100 Yes
ms
• Basic conversion time (ms) up to 4 channels: Up to 4 channels: 30 / 50 / 60 / 300 ms 10 ms
10 ms per module, 10 ms per module, (4-channel mode);
over 5 channels: 5 channels upwards: 95/83/72/23 ms
190 ms per module, 190 ms per module (8-channel mode)
8 channels: 80 ms
• Integration time (ms) 10/ 16.67/ 20/ 100 ms
• Interference voltage suppression 400 / 60 / 50 / 10 Hz 400 / 60 / 50 Hz,
for interference frequency f1 in Hz combinations of 400,
60, 50 Hz
■ Technical specifications
Article number 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0 6ES7331-7PE10-0AB0 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0
SM331, 8AI, resistor, SM331, 8AI, 16BIT, SM331, 6AI, 16bit, SM331,8AI,+/-5/10V, SM331,8AI,+/-5/10V,
PT100/200/1000, . Thermocouples Thermocouple 1-5V,+/-20mA, 1-5V,+/-20mA,
0/4-20mA 0/4-20mA
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes Yes
• for current measurement Yes; with external Yes; with external
as 2-wire transducer transmitter; possible transmitter, current
with separate supply supply; possible with
for transmitter separate supply for
transmitter
■ Technical specifications
Article number 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0 6ES7331-7PE10-0AB0 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0
SM331, 8AI, resistor, SM331, 8AI, 16BIT, SM331, 6AI, 16bit, SM331,8AI,+/-5/10V, SM331,8AI,+/-5/10V,
PT100/200/1000, . Thermocouples Thermocouple 1-5V,+/-20mA, 1-5V,+/-20mA,
0/4-20mA 0/4-20mA
• Thermocouple, Type T: ±0.13%, See manual for details
relative to input range, (+/-) Type U: ±0.08%,
Type E: ±0.05%,
Type J: ±0.04%,
Type L: ±0.06%,
Type K: ±0.04%,
Type N: ±0.04%,
Type R: ±0.03%,
Type S: ±0.03%,
Type B: ±0.05%,
Type C: ±0.02%,
TXK/XK(L): ±0.67 %
5
accuracy in the
lower range of the
characteristic curve
Interrupts/diagnostics/
status information
Diagnostics function Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable
Alarms
• Diagnostic alarm Yes; Parameterizable Yes; Parameterizable Yes; channel by chan- Yes; Parameterizable Yes; Parameterizable
per group per group nel
• Limit value alarm Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable, Yes; Parameterizable
channels 0 and 2 all channels (end of
cycle interrupt is also
supported across
modules)
• Hardware interrupt Yes; Parameterizable, Yes; Parameterizable, Yes; Parameterizable Yes; Parameterizable,
channels 0 to 7 channels 0 to 7 channels 0 to 7 (on
exceeding limit value),
at end of cycle
Connection method
required front connector 40-pin 40-pin 40-pin 40-pin 40-pin
Dimensions
Width 40 mm 40 mm 40 mm 40 mm 40 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm 117 mm 117 mm
Weights
Weight, approx. 272 g 272 g 272 g 272 g 272 g
■ Overview
• Analog outputs
• For the connection of analog actuators
■ Technical specifications
Article number 6ES7332-5HB01-0AB0 6ES7332-5HD01-0AB0 6ES7332-5HF00-0AB0 6ES7332-7ND02-0AB0
SM332, 2AA, U/I, 11/12Bit SM332, 4AO, U/I, 11/12Bit SM332, 8AA, U/I, 11/12Bit SM332, 4AA, 0-10V, 0-5V,
+/-10V,+/-20mA
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V 24 V 24 V
Input current
from load voltage L+ (without load), 135 mA 240 mA 340 mA 290 mA
max.
from backplane bus 5 V DC, max. 60 mA 60 mA 100 mA 120 mA
Power loss
Power loss, typ.
Analog outputs
3W 3W 6W 3W
5
Number of analog outputs 2 4 8 4; Isochronous mode
Voltage output, short-circuit protection Yes Yes Yes Yes
Voltage output, short-circuit current, 25 mA 25 mA 25 mA 40 mA
max.
Current output, no-load voltage, max. 18 V 18 V 18 V 18 V
Output ranges, voltage
• 0 to 10 V Yes Yes Yes Yes
• 1 V to 5 V Yes Yes Yes Yes
• -10 V to +10 V Yes Yes Yes Yes
Output ranges, current
• 0 to 20 mA Yes Yes Yes Yes
• -20 mA to +20 mA Yes Yes Yes Yes
• 4 mA to 20 mA Yes Yes Yes Yes
Load impedance
(in rated range of output)
• with voltage outputs, min. 1 kΩ 1 kΩ 1 kΩ 1 kΩ
• with voltage outputs, capacitive 1 µF 1 µF 1 µF 1 µF
load, max.
• with current outputs, max. 500 Ω 500 Ω 500 Ω 500 Ω
• with current outputs, inductive load, 10 mH 10 mH 10 mH 1 mH
max.
Cable length
• shielded, max. 200 m 200 m 200 m 200 m
Analog value generation
for the outputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 12 bit; ±10 V, ±20 mA, 12 bit; ±10 V, ±20 mA, 12 bit; ±10 V, ±20 mA, 16 bit
(bit including sign), max. 4 mA to 20 mA, 1 V to 5 V: 4 mA to 20 mA, 1 V to 5 V: 4 mA to 20 mA, 1 V to 5 V:
11 bit + sign; 0 V to 10 V, 11 bit + sign; 0 V to 10 V, 11 bit + sign; 0 V to 10 V,
0 mA to 20 mA: 12 bit 0 mA to 20 mA: 12 bit 0 mA to 20 mA: 12 bit
• Conversion time (per channel) 0.8 ms 0.8 ms 0.8 ms 200 µs; in isochronous mode
640 µs
Settling time
• for resistive load 0.2 ms 0.2 ms 0.2 ms 0.2 ms
• for capacitive load 3.3 ms 3.3 ms 3.3 ms 3.3 ms
• for inductive load 0.5 ms; 0.5 ms (1 mH); 0.5 ms; 0.5 ms (1 mH); 0.5 ms; 0.5 ms (1 mH); 0.5 ms
3.3 ms (10 mH) 3.3 ms (10 mH) 3.3 ms (10 mH)
■ Technical specifications
Article number 6ES7332-5HB01-0AB0 6ES7332-5HD01-0AB0 6ES7332-5HF00-0AB0 6ES7332-7ND02-0AB0
SM332, 2AA, U/I, 11/12Bit SM332, 4AO, U/I, 11/12Bit SM332, 8AA, U/I, 11/12Bit SM332, 4AA, 0-10V, 0-5V,
+/-10V,+/-20mA
Errors/accuracies
Operational error limit in overall
temperature range
• Voltage, relative to output range, 0.5 % 0.5 % 0.5 % 0.12 %
(+/-)
• Current, relative to output range, 0.6 % 0.6 % 0.6 % 0.18 %
(+/-)
Basic error limit
(operational limit at 25 °C)
5 • Voltage, relative to output range,
(+/-)
0.4 % 0.4 % 0.4 % 0.02 %
■ Overview
• Analog inputs and outputs
• For the connection of analog sensors and actuators
■ Technical specifications
Article number 6ES7334-0CE01-0AA0 6ES7334-0KE00-0AB0
SM334, 4AI, 2AO, non isolated SM334, 4AI/2AO, 0-10V f.PT100
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from supply and load voltage L+ 110 mA 80 mA
(without load), max.
from backplane bus 5 V DC, max. 55 mA 60 mA
Power loss
Power loss, typ. 3W 2W
5 Analog inputs
Number of analog inputs 4 4
• For voltage measurement 4 2
• For resistance measurement 4
permissible input voltage for voltage 20 V 20 V; continuous; 75 V for max. 1 s
input (destruction limit), max. (mark to space ratio 1:20)
permissible input current for current 40 mA
input (destruction limit), max.
Cycle time (all channels) max. 5 ms 85 ms
Input ranges (rated values),
voltages
• 0 to +10 V Yes Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes
Input ranges (rated values),
resistance thermometer
• Pt 100 Yes; only climatic range
Input ranges (rated values),
resistors
• 0 to 10000 ohms Yes
Characteristic linearization
• parameterizable Yes
- for resistance thermometer Pt100 (climate)
Cable length
• shielded, max. 200 m 100 m
Analog outputs
Number of analog outputs 2 2
Voltage output, short-circuit protection Yes Yes
Voltage output, short-circuit current, 11 mA 30 mA
max.
Current output, no-load voltage, max. 15 V
Output ranges, voltage
• 0 to 10 V Yes Yes
Output ranges, current
• 0 to 20 mA Yes
Load impedance
(in rated range of output)
• with voltage outputs, min. 5 kΩ 2.5 kΩ
• with voltage outputs, capacitive 1 µF 1 µF
load, max.
• with current outputs, max. 300 Ω
• with current outputs, inductive load, 1 mH
max.
Cable length
• shielded, max. 200 m 100 m
■ Technical specifications
Article number 6ES7334-0CE01-0AA0 6ES7334-0KE00-0AB0
SM334, 4AI, 2AO, non isolated SM334, 4AI/2AO, 0-10V f.PT100
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 8 bit 12 bit
(bit including sign), max.
• Integration time, parameterizable No Yes
Analog value generation
for the outputs
5
Integration and conversion time/
resolution per channel
• Resolution with overrange 8 bit 12 bit
(bit including sign), max.
• Conversion time (per channel) 500 µs 500 µs
Settling time
• for resistive load 0.3 ms 0.8 ms
• for capacitive load 3 ms 0.8 ms
• for inductive load 0.3 ms
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes
• for current measurement No
as 2-wire transducer
• for current measurement Yes
as 4-wire transducer
• for resistance measurement Yes
with two-wire connection
• for resistance measurement Yes
with three-wire connection
• for resistance measurement Yes
with four-wire connection
Errors/accuracies
Operational error limit
in overall temperature range
• Voltage, relative to input range, (+/-) 0.9 % 0.7 %; 0 to 10V
• Current, relative to input range, (+/-) 0.8 %
• Resistance, relative to input range, 3.5 %
(+/-)
• Resistance thermometer, 1%
relative to input range, (+/-)
• Voltage, relative to output range, 0.6 % 1%
(+/-)
• Current, relative to output range, 1%
(+/-)
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input range, (+/-) 0.7 % 0.5 %; 0 to 10V
• Current, relative to input range, (+/-) 0.6 %
• Resistance, relative to input range, 2.8 %
(+/-)
• Resistance thermometer, 0.8 %
relative to input range, (+/-)
• Voltage, relative to output range, 0.5 % 0.85 %
(+/-)
• Current, relative to output range, 0.5 %
(+/-)
■ Technical specifications
Article number 6ES7334-0CE01-0AA0 6ES7334-0KE00-0AB0
SM334, 4AI, 2AO, non isolated SM334, 4AI/2AO, 0-10V f.PT100
Interrupts/diagnostics/
status information
Alarms No No
Diagnostics function No No
Connection method
required front connector 20-pin 20-pin
Dimensions
Width 40 mm 40 mm
Height 125 mm 125 mm
5 Depth 117 mm 117 mm
Weights
Weight, approx. 285 g 200 g
■ Overview
• Analog inputs
• For connecting voltage sensors and current sensors,
thermocouples, resistors and resistance thermometers
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
■ Technical specifications
Article number 6AG1331-1KF02-7AB0 6AG1331-7KB02-2AB0 6AG1331-7KF02-2AB0
Based on 6ES7331-1KF02-0AB0 6ES7331-7KB02-0AB0 6ES7331-7KF02-0AB0
SIPLUS SM331 8AI SIPLUS SM331 2AE SIPLUS SM331 8AI
Ambient conditions
Ambient temperature
during operation
• min. -25 °C -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, 70 °C; = Tmax; 60 °C @ UL/cUL, 70 °C; = Tmax; for use on railway
ATEX and FM use ATEX and FM use vehicles according to EN50155, the
rated temperature range -25 ... +55 °C
(T1) or 60 °C @ UL/ULhaz/ATEX/FM
use applies
5 Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of
fauna); Class 3B3 on request fauna); Class 3B3 on request fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus and dry
according to EN 60721-3-5 rot spores (with the exception of
fauna); Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %) incl. salt
according to EN 60721-3-5 spray acc. to EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand, dust; *
according to EN 60721-3-5
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold and fungal spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on (excluding fauna); Class 6B3 on
request request request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52 incl. salt spray acc. to EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful (excluding trichlorethylene; harmful
systems acc. to ANSI/ISA-71.04 gas concentrations up to the limits of gas concentrations up to the limits of gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible); EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3 level LC3 (salt spray) and level LB3
(oil) (oil) (oil)
Remark
- Note regarding classification * The supplied plug covers must * The supplied plug covers must * The supplied plug covers must
of environmental conditions remain in place over the unused remain in place over the unused remain in place over the unused
acc. to EN 60721, EN 60654-4 interfaces during operation! interfaces during operation! interfaces during operation!
and ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1331-7NF00-2AB0 6AG1331-7NF10-2AB0 6AG1331-7PF01-4AB0 6AG1331-7PF11-4AB0
Based on 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0
SIPLUS S7-300 SM331 SIPLUS SM331 8AI - 40-pin SIPLUS SM331 8AI SIPLUS S7-300 SM331
8AI - 40-pin 8AI 40-pin
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin 0 °C; = Tmin 0 °C; = Tmin
• max. 70 °C; = Tmax; for use on 60 °C; = Tmax 60 °C; = Tmax 60 °C; = Tmax
railway vehicles according to
EN 50155, the rated
temperature range
-25 ... +55 °C (T1) o
r 60 °C @ UL/UL hazardous 5
use applies
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus
according to EN 60721-3-5 and dry rot spores (with the
exception of fauna); Class
5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %)
according to EN 60721-3-5 incl. salt spray acc. to
EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand,
according to EN 60721-3-5 dust; *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1331-7NF00-2AB0 6AG1331-7NF10-2AB0 6AG1331-7PF01-4AB0 6AG1331-7PF11-4AB0
Based on 6ES7331-7NF00-0AB0 6ES7331-7NF10-0AB0 6ES7331-7PF01-0AB0 6ES7331-7PF11-0AB0
SIPLUS S7-300 SM331 SIPLUS SM331 8AI - 40-pin SIPLUS SM331 8AI SIPLUS S7-300 SM331
8AI - 40-pin 8AI 40-pin
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
■ Overview
• Analog outputs
• For connection of analog actuators
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
■ Technical specifications
Article number 6AG1332-5HD01-7AB0 6AG1332-7ND02-4AB0 6AG1332-5HB01-2AB0 6AG1332-5HF00-2AB0
Based on 6ES7332-5HD01-0AB0 6ES7332-7ND02-0AB0 6ES7332-5HB01-0AB0 6ES7332-5HF00-0AB0
SIPLUS S7-300 SIPLUS S7-300 SIPLUS S7-300 SIPLUS S7-300
SM332 4AA U/I SM332 4AA SM332 2AO SM 332 8AO - 40pol
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin 0 °C; = Tmin -25 °C; = Tmin -25 °C
• max. 70 °C; = Tmax; 60 °C; = Tmax 70 °C; = Tmax; for use on 70 °C; = Tmax;
60 °C @ UL/cUL, ATEX and railway vehicles according to 60 °C @ UL/cUL, ATEX and
FM use EN50155, the rated tempera- FM use
ture range -25 ... +55 °C (T1)
5 or 60 °C @
UL/ULhaz/ATEX/FM use
applies
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus Yes; Class 3B2 mold, fungus
according to EN 60721-3-3 and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the and dry rot spores (with the
exception of fauna); exception of fauna); exception of fauna); exception of fauna);
Class 3B3 on request Class 3B3 on request Class 3B3 on request Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %) Yes; Class 3C4 (RH < 75 %)
according to EN 60721-3-3 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand, Yes; Class 3S4 incl. sand,
according to EN 60721-3-3 dust, * dust, * dust, * dust, *
Use on land craft, rail vehicles and
special-purpose vehicles
- to biologically active substances Yes; Class 5B2 mold, fungus
according to EN 60721-3-5 and dry rot spores (with the
exception of fauna);
Class 5B3 on request
- to chemically active substances Yes; Class 5C3 (RH < 75 %)
according to EN 60721-3-5 incl. salt spray acc. to
EN 50155 (ST2); *
- to mechanically active substances Yes; Class 5S3 incl. sand,
according to EN 60721-3-5 dust; *
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and Yes; Class 6B2 mold and
according to EN 60721-3-6 fungal spores (excluding fungal spores (excluding fungal spores (excluding fungal spores (excluding
fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request fauna); Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %) Yes; Class 6C3 (RH < 75 %)
according to EN 60721-3-6 incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to incl. salt spray acc. to
EN 60068-2-52 EN 60068-2-52 EN 60068-2-52 EN 60068-2-52
(severity degree 3); * (severity degree 3); * (severity degree 3); * (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand, Yes; Class 6S3 incl. sand,
according to EN 60721-3-6 dust; * dust; * dust; * dust; *
■ Technical specifications
Article number 6AG1332-5HD01-7AB0 6AG1332-7ND02-4AB0 6AG1332-5HB01-2AB0 6AG1332-5HF00-2AB0
Based on 6ES7332-5HD01-0AB0 6ES7332-7ND02-0AB0 6ES7332-5HB01-0AB0 6ES7332-5HF00-0AB0
SIPLUS S7-300 SIPLUS S7-300 SIPLUS S7-300 SIPLUS S7-300
SM332 4AA U/I SM332 4AA SM332 2AO SM 332 8AO - 40pol
Usage in industrial process
technology
- Against chemically active Yes; Class 3 Yes; Class 3 Yes; Class 3 Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene) (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene; (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations harmful gas concentrations harmful gas concentrations harmful gas concentrations
up to the limits of up to the limits of up to the limits of up to the limits of
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
EN 60721-3-3 class 3C4
permissible); level LC3 (salt
spray) and level LB3 (oil)
5
Remark
- Note regarding classification * The supplied plug covers * The supplied plug covers * The supplied plug covers * The supplied plug covers
of environmental conditions must remain in place over must remain in place over must remain in place over must remain in place over
acc. to EN 60721, EN 60654-4 the unused interfaces during the unused interfaces during the unused interfaces during the unused interfaces during
and ANSI/ISA-71.04 operation! operation! operation! operation!
■ Overview
• Analog inputs and outputs
• For connection of analog sensors and actuators
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
■ Technical specifications
Article number 6AG1334-0KE00-7AB0 Article number 6AG1334-0KE00-7AB0
Based on 6ES7334-0KE00-0AB0 Based on 6ES7334-0KE00-0AB0
SIPLUS S7-300 SM334 4AE 2AA SIPLUS S7-300 SM334 4AE 2AA
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold and fungal
during operation according to EN 60721-3-6 spores (excluding fauna); Class 6B3
• min. -25 °C; = Tmin on request
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
ATEX and FM use according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
(severity degree 3); *
Altitude during operation
relating to sea level - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
• Installation altitude above sea level, 5 000 m
max. Usage in industrial process
technology
5
• Ambient air temperature- Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa - Against chemically active Yes; Class 3
(-1 000 m ... +2 000 m) // substances acc. to EN 60654-4 (excluding trichlorethylene)
Tmin ... (Tmax - 10 K) at - Environmental conditions for Yes; Level GX group A/B
795 hPa ... 658 hPa process, measuring and control (excluding trichlorethylene;
(+2 000 m ... +3 500 m) // systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to the
Tmin ... (Tmax -20 K) at limits of EN 60721-3-3 class 3C4
658 hPa ... 540 hPa permissible); level LC3 (salt spray)
(+3 500 m ... +5 000 m) and level LB3 (oil)
Resistance Remark
Use in stationary industrial systems - Note regarding classification * The supplied plug covers must
- to biologically active substances Yes; Class 3B2 mold, fungus and of environmental conditions remain in place over the unused
according to EN 60721-3-3 dry rot spores (with the exception of acc. to EN 60721, EN 60654-4 interfaces during operation!
fauna); Class 3B3 on request and ANSI/ISA-71.04
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl.
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Overview
• Digital inputs for the fail-safe SIMATIC S7 systems
• For connecting:
- Switches and 2-wire proximity switches
- Sensors according to NAMUR and mechanical contacts,
also for signals from hazardous areas
• With integral safety functions for fail-safe operation
• Can be used in fail-safe operation
- Centrally: with S7-31xF-2 DP
- Distributed in ET 200M: with SIMATIC IM 151-7 F-CPU,
S7-31xF-2 DP, S7-416F-2 and S7-400F/FH
• In standard operation can be used in the same way as
5 S7-300 modules
Floating license for 1 user; software 6ES7833-1FC02-0YA5 Floating license for 1 user; 6ES7833-1FA17-0YH5
and documentation on DVD; license key for download1);
license key on USB flash drive Email address required for delivery
■ Technical specifications
Article number 6ES7326-1RF01-0AB0 6ES7326-1BK02-0AB0
SM326, 8DE, DC24V, failsafe SM326, F-DI 24 X DC24V, failsafe
Supply voltage
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), 160 mA 450 mA
max.
from backplane bus 5 V DC, max. 90 mA 100 mA
Encoder supply
Number of outputs 8 4; Isolated
Output current
• Rated value 400 mA
Power loss
Power loss, typ. 4.5 W 10 W
Digital inputs
Number of digital inputs 8 24
Input voltage
• Type of input voltage DC DC
• Rated value (DC) 24 V
• for signal "0" -30 to +5 V
• for signal "1" +11 to +30V
Input current
• for signal "1", typ. 2.1 to 7 mA 10 mA
Input delay
(for rated value of input voltage)
for standard inputs
- at "0" to "1", max. 3.4 ms
for NAMUR inputs
- at "0" to "1", max. 1.2 to 3 ms
- at "1" to "0", max. 1.2 to 3 ms
Cable length
• shielded, max. 200 m 200 m
■ Technical specifications
Article number 6ES7326-1RF01-0AB0 6ES7326-1BK02-0AB0
SM326, 8DE, DC24V, failsafe SM326, F-DI 24 X DC24V, failsafe
Encoder
Connectable encoders
• 2-wire sensor Yes; if short-circuit test is deactivated
- permissible quiescent current 2 mA
(2-wire sensor), max.
Interrupts/diagnostics/
status information
Diagnostics function Yes
Alarms
5 • Diagnostic alarm
Ex(i) characteristics
Yes; Parameterizable Yes
■ Overview
• Digital outputs for the fail-safe SIMATIC S7 systems
• Two versions (1 x switching to P/P potential,
1 x switching to P/M potential)
• For connecting solenoid valves, DC contactors and indicator
lights
• With integral safety functions for fail-safe operation
• Can be used in fail-safe operation
- Centrally: with S7-31xF DP, S7-31xF PN/DP
- Distributed in ET 200M: with SIMATIC IM 151-7 F-CPU,
S7-31xF-2 DP, S7-41xF-2 and S7-400F/FH
■ Technical specifications
Article number 6ES7326-2BF10-0AB0 6ES7326-2BF41-0AB0
SM326, F-DO10XDC24V/2A PP, failsafe SM 326, F-DO 8 X DC 24V/2A PM
Supply voltage
Rated value (DC) 24 V; 1L+ 24 V; 1L+
Load voltage L+
• Rated value (DC) 24 V; 2L+, 3L+ 24 V; 2L+, 3L+
Input current
from supply voltage 1L+, max. 100 mA 75 mA
from load voltage 2L+ (without load), 100 mA 100 mA
max.
from load voltage 3L+ (without load), 100 mA 100 mA
max.
from backplane bus 5 V DC, max. 100 mA 100 mA
Power loss
Power loss, typ. 6W 12 W
Digital outputs
Number of digital outputs 10 8
Short-circuit protection Yes Yes
Limitation of inductive shutdown L+ (-33 V)
voltage to
Switching capacity of the outputs
• on lamp load, max. 5W 5W
Output voltage
• for signal "1", min. L+ (-1.0 V) L+ (-1.0 V)
Output current
• for signal "1" rated value 2A 2A
• for signal "0" residual current, max. 0.5 mA 0.5 mA
Switching frequency
• with resistive load, max. 25 Hz 30 Hz
• with inductive load, max. 25 Hz 2 Hz
• on lamp load, max. 10 Hz 10 Hz
■ Technical specifications
Article number 6ES7326-2BF10-0AB0 6ES7326-2BF41-0AB0
SM326, F-DO10XDC24V/2A PP, failsafe SM 326, F-DO 8 X DC 24V/2A PM
Total current of the outputs
(per group)
horizontal installation
- up to 40 °C, max. 10 A 7.5 A
- up to 60 °C, max. 6A 5A
vertical installation
- up to 40 °C, max. 5A 5A
Cable length
• shielded, max. 1 000 m 200 m; 200 m for SIL 3, AK 6, Cat 4
Interrupts/diagnostics/
status information
5
Alarms
• Diagnostic alarm Yes Yes; Parameterizable
Standards, approvals, certificates
Highest safety class achievable
in safety mode
• acc. to DIN VDE 0801 AK 5 and 6
• acc. to EN 954 Cat. 4 Cat. 4
• SIL acc. to IEC 61508 SIL 3 SIL 3
Connection method
required front connector 40-pin 40-pin
Dimensions
Width 40 mm 80 mm
Height 125 mm 125 mm
Depth 120 mm 120 mm
Weights
Weight, approx. 330 g 465 g
■ Overview
• Analog inputs for fail-safe SIMATIC S7 systems
• Can be used in the ET 200M distributed I/O device with
IM 153-2 HF as well as centrally with SIMATIC S7-31xF-2 DP
• Properties of the SM 336; F-AI 6 x 0/4 ... 20 mA HART:
- 6 analog inputs with galvanic isolation between channels
and backplane bus
- Input ranges: 0 mA to 20 mA, 4 mA to 20 mA
- Short-circuit-proof power supply of 2- or 4-wire transmitters
via the module
- External encoder supply possible
- Can be used in safety mode
- HART communication
5 - Firmware update using HW Config
- Identification data
■ Technical specifications
Article number 6ES7336-4GE00-0AB0 Article number 6ES7336-4GE00-0AB0
SM 336, f.AI 6 X 0/4 ... 20mA HART SM 336, f.AI 6 X 0/4 ... 20mA HART
Supply voltage Errors/accuracies
Rated value (DC) 24 V Operational error limit in overall
Load voltage L+ temperature range
• Rated value (DC) 24 V • Current, relative to input range, (+/-) 0.2 %
Input current Basic error limit
(operational limit at 25 °C)
From power supply L+, typ. 150 mA
• Current, relative to input range, (+/-) 0.1 %
from backplane bus 5 V DC, max. 90 mA
Interrupts/diagnostics/
Power loss status information
Power loss, typ. 4.5 W Diagnostics function Yes
Analog inputs Alarms
Number of analog inputs 6 • Diagnostic alarm Yes
permissible input current for current 40 mA Standards, approvals, certificates
input (destruction limit), max.
Highest safety class achievable
Input ranges (rated values), currents in safety mode
• 0 to 20 mA Yes • SIL acc. to IEC 61508 SIL 3
• 4 mA to 20 mA Yes Connection method
Cable length required front connector 20-pin
• shielded, max. 1 000 m Dimensions
Analog value generation Width 40 mm
for the inputs
Height 125 mm
Integration and conversion time/
resolution per channel Depth 120 mm
• Resolution with overrange 16 bit; 15 bit + sign Weights
(bit including sign), max. Weight, approx. 350 g
• Integration time (ms) 20 ms @ 50 Hz, 16.7 ms @ 60 Hz
• Interference voltage suppression f=n x (f1 ±0.5 %)
for interference frequency f1 in Hz
Encoder
Connection of signal encoders
• for current measurement Yes
as 2-wire transducer
• for current measurement Yes
as 4-wire transducer
■ Technical specifications
Article number
5
6ES7195-7KF00-0XA0
Safety Protector
betw. F- and Std-Mod.
General information
Product type designation Safety protector
Weights
Weight, approx. 10 g
• Supports mixed operation of fail-safe signal modules
in safety mode and S7-300 standard modules in an
ET 200M distributed I/O device for achieving Cat. 4 or SIL 3.
• The safety protector is not required if the safety class or
safety category to be achieved is less than SIL 3 or Cat. 4,
respectively.
When Cat. 4/SIL 3 is required, the safety protector must be
implemented in the following situations:
Application Safety protector must be used
Central use after CPU 31xF-2 DP or
CPU 31xF-2 PN/DP
• Only fail-safe modules in the tier Yes, behind the CPU
• Standard and fail-safe modules Yes, after the last standard module
in the tier and before the first fail-safe module
Central use after CPU 31xF-2 DP
or CPU 31xF-2 PN/DP
in an expansion rack
• Only fail-safe modules in the tier Yes, after the IM 36x
• Standard and fail-safe modules Yes, after the last standard module
in the tier and before the first fail-safe module
Distributed behind the IM 153-2
with copper connection
• Only fail-safe modules in the station Yes, after the IM 153-2
• Standard and fail-safe modules Yes, after the last standard module
in the station and before the first fail-safe module
Distributed behind the IM 153-2
with fiber-optic connection
• Only fail-safe modules in the station No
• Standard and fail-safe modules Yes, after the last standard module
in the station and before the first fail-safe module
■ Overview
• Digital inputs for the fail-safe SIPLUS S7 systems
• For connecting:
- Switches and 2-wire proximity switches
- Sensors according to NAMUR and mechanical contacts,
also for signals from hazardous areas
• With integral safety functions for fail-safe operation
• Can be used in fail-safe operation
- Centrally: with S7-31xF-2 DP
- Distributed in ET 200M: with SIMATIC IM 151-7 F-CPU,
S7-31xF-2 DP, S7-416F-2 and S7-400F/FH
• In standard operation can be used in the same way as
S7-300 modules
Note:
5
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1326-1BK02-2AB0 6AG1326-1RF01-4AB0
Based on 6ES7326-1BK02-0AB0 6ES7326-1RF01-0AB0
SIPLUS S7-300 SM326F DI24 SIPLUS S7-300 SM326F DI8 NAMUR
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin 0 °C; = Tmin
• max. 60 °C; = Tmax; *+70 °C where forced convection with a 60 °C; = Tmax
minimum air velocity of 0.7 m/s through the modules and
rated voltage of 24 V ±5 % are ensured. If in the course of
maintenance or automatic diagnosis it is determined that
the admissible specified parameters have been exceeded,
the modules should be subjected to a proof test
(function check) by the manufacturer.
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
■ Technical specifications
Article number 6AG1326-1BK02-2AB0 6AG1326-1RF01-4AB0
Based on 6ES7326-1BK02-0AB0 6ES7326-1RF01-0AB0
SIPLUS S7-300 SM326F DI24 SIPLUS S7-300 SM326F DI8 NAMUR
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray Yes; Class 3C4 (RH < 75 %) incl. salt spray
according to EN 60721-3-3 acc. to EN 60068-2-52 (severity degree 3); * acc. to EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
5
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray Yes; Class 6C3 (RH < 75 %) incl. salt spray
according to EN 60721-3-6 acc. to EN 60068-2-52 (severity degree 3); * acc. to EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Overview
• Digital outputs for the fail-safe SIMATIC S7 systems
• For connection of solenoid valves, DC contactors and
indicator lights
• With integral safety functions for fail-safe operation
• Can be used in fail-safe mode
- Centrally: with S7-31xF-2 DP
- Distributed in ET 200M: with SIMATIC IM 151-7 F-CPU,
S7-31xF-2 DP, S7-416F-2 and S7-400F/FH
Note:
SIPLUS extreme products are based on SIMATIC standard
5 products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1326-2BF10-2AB0 6AG1326-2BF41-2AB0
Based on 6ES7326-2BF10-0AB0 6ES7326-2BF41-0AB0
SIPLUS S7-300 SM326F 10 DO SIPLUS S7-300 SM326F DO8
Ambient conditions
Ambient temperature
during operation
• min. -25 °C -25 °C
• max. 60 °C; = T max; *+70 °C when forced convection 60 °C
at a minimum air speed of 0.3 m/s through the modules
is ensured. If in the course of maintenance or automatic
diagnosis it is determined that the admissible specified
parameters have been exceeded, the modules should be
subjected to a proof test (function check) by the
manufacturer.
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
■ Technical specifications
Article number 6AG1326-2BF10-2AB0 6AG1326-2BF41-2AB0
Based on 6ES7326-2BF10-0AB0 6ES7326-2BF41-0AB0
SIPLUS S7-300 SM326F 10 DO SIPLUS S7-300 SM326F DO8
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray Yes; Class 3C4 (RH < 75 %) incl. salt spray
according to EN 60721-3-3 acc. to EN 60068-2-52 (severity degree 3); * acc. to EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Overview
• Properties of the SM 336; F-AI 6 x 0/4 ... 20 mA HART:
- 6 analog inputs with galvanic isolation between channels
and backplane bus
- Input ranges: 0 mA to 20 mA, 4 mA to 20 mA
- Short-circuit proof power supply of 2 or 4-wire transmitter
via the module
- External encoder supply possible
- Applicable in safety mode
- HART communication
- Firmware update using HW Config
- Identification data
- Temperature range -25 ... +70 °C;
(+70 °C when ensuring a forced convection with a minimal
air velocity of 0.3 m/s through the module. If a violation of 5
the permissible, specified parameters is detected during
maintenance or by automatic diagnostics, the modules must
be proof-tested by the manufacturer. Without this measure
the temperature range is -25…60°C)
Note:
• Analog inputs for fail-safe SIPLUS S7 systems SIPLUS extreme products are based on SIMATIC standard
• Applicable in the ET 200M distributed I/O device with products. The contents listed here were taken from the
IM 153-2 HF as well as centrally with SIPLUS S7-31xF-2 DP respective standard products. SIPLUS extreme specific
information was added.
■ Overview
• Digital inputs for signals from the Ex field
• For the connection of intrinsically safe digital equipment from
the Ex field
• 4 DI NAMUR
• 4 digital inputs in 4 channel modules (single-channel isolation)
• Connectable encoder in accordance with EN 60947-5-6 and
NAMUR, optionally with wired or unwired mechanical contacts
• Diagnostics and diagnostics alarm programmable
■ Technical specifications
Article number 6ES7321-7RD00-0AB0 Article number 6ES7321-7RD00-0AB0
SM321, 4DI, DC24V, SM321, 4DI, DC24V,
HAZARDOUS AREAS HAZARDOUS AREAS
Supply voltage Ex(i) characteristics
Load voltage L+ Module for Ex(i) protection Yes
• Rated value (DC) 24 V maximum values for connecting
Input current terminals for gas group IIC
from load voltage L+ (without load), 50 mA • Uo (no-load voltage), max. 10 V
max. • Io (short-circuit current), max. 14.1 mA
from backplane bus 5 V DC, max. 80 mA • Po (power output), max. 33.7 mW
Power loss • Co (permissible external capacity), 3 µF
Power loss, typ.
Digital inputs
1.1 W max.
• Lo (permissible external inductivity), 100 mH 5
max.
Number of digital inputs 4
Standards, approvals, certificates
Number of NAMUR inputs 4
Use in hazardous areas
Input voltage
• Test number PTB Ex-96.D.2094X
• Type of input voltage DC
Ambient conditions
• Rated value (DC) 8.2 V; from internal power circuit
supply Ambient temperature
during operation
Input current
• max. 60 °C
• on wire-break, max. 0.1 mA
Connection method
• on short-circuit, max. 8.5 mA
required front connector 20-pin
for NAMUR encoders
Dimensions
- for signal "0" 0.35 to 1.2 mA
Width 40 mm
- for signal "1" 2.1 to 7 mA
Height 125 mm
Input delay
(for rated value of input voltage) Depth 120 mm
• Input frequency 2 kHz Weights
(with a time delay of 0.1 ms), max. Weight, approx. 230 g
for NAMUR inputs
- parameterizable Yes; 0.1 / 0.5 / 3 / 15 / 20 ms
(plus 0.25 ms preparation time)
Encoder
Connectable encoders
• NAMUR encoder Yes; Two-wire connection
Interrupts/diagnostics/
status information
Diagnostics function Yes
■ Overview
• Digital outputs for signals from the Ex field
• For the connection of intrinsically safe digital equipment
from the Ex field
• 4 DO 24 V DC/10mA or 4 DO 15 V DC/20 mA
• 4 digital outputs in 4 channel modules
(single-channel isolation)
• Diagnostics and diagnostics alarm programmable
• Substitute value behavior programmable
■ Technical specifications
Article number 6ES7322-5SD00-0AB0 6ES7322-5RD00-0AB0
SM322, 4DO, 24V DC,10MA, HAZARDOUS AREAS SM322, 4DO, 15V DC,20MA, HAZARDOUS AREAS
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from load voltage L+ (without load), 160 mA 160 mA
max.
from backplane bus 5 V DC, max. 85 mA 85 mA
Power loss
Power loss, typ. 3W 3W
Digital outputs 5
Number of digital outputs 4 4
Short-circuit protection Yes; Electronic Yes; Electronic
Load resistance range
• upper limit 390 Ω; Two-wire connection 200 Ω; Two-wire connection
Output voltage
• Rated value (DC) 24 V 15 V
Switching frequency
• with resistive load, max. 100 Hz 100 Hz
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes
Ex(i) characteristics
Module for Ex(i) protection Yes Yes
maximum values for connecting
terminals for gas group IIC
• Uo (no-load voltage), max. 25.2 V 15.75 V
• Io (short-circuit current), max. 70 mA 85 mA
• Po (power output), max. 440 mW 335 mW
• Co (permissible external capacity), 90 nF 500 nF
max.
• Lo (permissible external inductivity), 6.7 mH 5 mH
max.
Standards, approvals, certificates
Use in hazardous areas
• Test number PTB Ex-96.D.2093X Ex-96.D.2102X
Ambient conditions
Ambient temperature
during operation
• max. 60 °C 60 °C
Connection method
required front connector 20-pin 20-pin
Dimensions
Width 40 mm 40 mm
Height 125 mm 125 mm
Depth 120 mm 120 mm
Weights
Weight, approx. 230 g 230 g
■ Overview
• Digital inputs for signals from the Ex field
• For the connection of intrinsically safe digital equipment from
the Ex field
• 4 DI NAMUR
• 4 digital inputs in 4 channel modules (single-channel isolation)
• Connectable encoder in accordance with EN 60947-5-6 and
NAMUR, optionally with wired or unwired mechanical contacts
• Programmable diagnostics and diagnostic interrupt
Note:
SIPLUS extreme products are based on SIMATIC standard
5 products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1321-7RD00-4AB0 Article number 6AG1321-7RD00-4AB0
Based on 6ES7321-7RD00-0AB0 Based on 6ES7321-7RD00-0AB0
SIPLUS S7-300 SM 321 4DI NAMUR SIPLUS S7-300 SM 321 4DI NAMUR
Ambient conditions Resistance
Ambient temperature Use in stationary industrial systems
during operation - to biologically active substances Yes; Class 3B2 mold, fungus and dry
• min. 0 °C; = Tmin according to EN 60721-3-3 rot spores (with the exception of
• max. 60 °C; = Tmax fauna); Class 3B3 on request
Altitude during operation - to chemically active substances Yes; Class 3C4 (RH < 75 %) incl.
relating to sea level according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
• Installation altitude above sea level, 5 000 m
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
max.
• Ambient air temperature- Tmin ... Tmax at
according to EN 60721-3-3
Use on ships/at sea
5
barometric pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // - to biologically active substances Yes; Class 6B2 mold and fungal
Tmin ... (Tmax - 10 K) at according to EN 60721-3-6 spores (excluding fauna);
795 hPa ... 658 hPa Class 6B3 on request
(+2 000 m ... +3 500 m) // - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
Tmin ... (Tmax -20 K) at according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
658 hPa ... 540 hPa (severity degree 3); *
(+3 500 m ... +5 000 m)
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
Relative humidity according to EN 60721-3-6
• With condensation, 100 %; RH incl. condensation/frost Usage in industrial process
tested in accordance (no commissioning under technology
with IEC 60068-2-38, max. condensation conditions)
- Against chemically active Yes; Class 3
substances acc. to EN 60654-4 (excluding trichlorethylene)
- Environmental conditions for Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene;
systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
the limits of EN 60721-3-3 class 3C4
permissible); level LC3 (salt spray)
and level LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must
of environmental conditions remain in place over the unused
acc. to EN 60721, EN 60654-4 interfaces during operation!
and ANSI/ISA-71.04
■ Overview
• Analog inputs for signals from the Ex field
• For the connection of intrinsically safe analog equipment
from the Ex field
• 8 or 4 analog inputs in 4 channel groups
(single-channel isolation)
• Measurement type and range can be selected for each
channel
• Diagnostics and diagnostics alarm programmable
• Programmable threshold alarm
• HART-compatible inputs (only 6ES7331-7RD00-0AB0)
■ Technical specifications
Article number 6ES7331-7RD00-0AB0 6ES7331-7SF00-0AB0
SIMATIC S7, SM 331 ANALOG INPUT SIMATIC S7, SM 331 ANALOG INPUT
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from load voltage L+ (without load), 250 mA
max.
from backplane bus 5 V DC, max. 60 mA 120 mA
Output voltage
5
Power supply to the transmitters
• Rated value (DC) 13 V; at 22 mA
Power loss
Power loss, typ. 3W 0.6 W
Analog inputs
Number of analog inputs 4 8; 8x thermocouples; 4x RTD thermoresistors
permissible input current for current 40 mA
input (destruction limit), max.
Input ranges (rated values),
voltages
• -1 V to +1 V Yes
• -25 mV to +25 mV Yes
• -250 mV to +250 mV Yes
• -50 mV to +50 mV Yes
• -500 mV to +500 mV Yes
• -80 mV to +80 mV Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes
• 4 mA to 20 mA Yes
Input ranges (rated values),
thermocouples
• Type B Yes
• Type E Yes
• Type J Yes
• Type K Yes
• Type L Yes
• Type N Yes
• Type R Yes
• Type S Yes
• Type T Yes
• Type U Yes
Input ranges (rated values),
resistance thermometer
• Ni 100 Yes
• Pt 100 Yes
• Pt 200 Yes
Cable length
• shielded, max. 200 m 200 m; TC: 50 m
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 16 bit; 10 bit to 15 bit + sign 16 bit; 10 bit to 15 bit + sign
(bit including sign), max.
• Integration time, parameterizable Yes; 2.5 to 100 ms Yes; 2.5 to 100 ms
• Interference voltage suppression 10 to 400 Hz 10 to 400 Hz
for interference frequency f1 in Hz
Encoder
Connection of signal encoders
• for current measurement Yes Yes
as 2-wire transducer
• for current measurement Yes Yes
as 4-wire transducer
■ Technical specifications
Article number 6ES7331-7RD00-0AB0 6ES7331-7SF00-0AB0
SIMATIC S7, SM 331 ANALOG INPUT SIMATIC S7, SM 331 ANALOG INPUT
Errors/accuracies
Operational error limit in overall
temperature range
• Current, relative to input range, (+/-) 0.45 %
• Resistance thermometer, 0.04 %; 0.09 to 0.04%
relative to input range, (+/-)
Basic error limit
(operational limit at 25 °C)
• Current, relative to input range, (+/-) 0.1 %
5 • Resistance thermometer,
relative to input range, (+/-)
0.008 %; 0.018 ... 0.008%
Interrupts/diagnostics/
status information
Diagnostics function Yes Yes
Ex(i) characteristics
Module for Ex(i) protection Yes Yes
maximum values for connecting
terminals for gas group IIC
• Uo (no-load voltage), max. 25.2 V 5.9 V
• Io (short-circuit current), max. 68.5 mA 28.8 mA
• Po (power output), max. 431 mW 41.4 mW
• Co (permissible external capacity), 90 nF 43 µF
max.
• Lo (permissible external inductivity), 7.5 mH 40 mH
max.
Standards, approvals, certificates
Use in hazardous areas
• Test number PTB Ex-96.D.2092X Ex-96.D.2108X
Ambient conditions
Ambient temperature
during operation
• max. 60 °C 60 °C
Connection method
required front connector 20-pin 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 290 g 210 g
■ Overview
• Analog outputs for signals from the Ex field
• For the connection of intrinsically safe analog equipment
from the Ex field
• 4 analog outputs in 4 channel modules
(single-channel isolation)
• Diagnostics and diagnostics alarm programmable
■ Technical specifications
Article number 6ES7332-5RD00-0AB0 Article number 6ES7332-5RD00-0AB0
SIMATIC S7,SM 332 SIMATIC S7,SM 332
ANALOG OUTPUT ANALOG OUTPUT
Supply voltage Interrupts/diagnostics/
Load voltage L+ status information
• Rated value (DC) 24 V Diagnostics function Yes
Input current Ex(i) characteristics
from load voltage L+ (without load), 200 mA Module for Ex(i) protection Yes
max. maximum values for connecting
from backplane bus 5 V DC, max. 80 mA terminals for gas group IIC
Power loss • Uo (no-load voltage), max. 14 V
■ Overview
• Analog inputs for signals from the Ex field
• For the connection of intrinsically safe analog equipment
from the Ex field
• 4 analog inputs in 4 channel groups (single-channel isolation)
• Measurement type and range can be selected for each
channel
• Programmable diagnostics and diagnostic interrupt
• Programmable threshold alarm
• HART-compatible inputs (6AG1 331-7RD00-2AB0 only)
Note:
SIPLUS extreme products are based on SIMATIC standard 5
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1331-7RD00-2AB0 6AG1331-7SF00-4AB0
Based on 6ES7331-7RD00-0AB0 6ES7331-7SF00-0AB0
SIPLUS S7-300 SM331 4AE SIPLUS S7-300 SM331 20-pin
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin 0 °C; = Tmin
• max. 60 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use, 60 °C; = Tmax
70 °C only 4 wire
Altitude during operation
relating to sea level
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Overview
• One-channel intelligent counter module for simple counting
tasks
• For direct connection of incremental encoders
• Comparison function with 2 specifiable comparison values
• Integrated digital outputs to output the response upon
reaching the comparison value.
• Operating modes:
- Continuous counting
- One-shot counting
- Periodic counting
• Special functions:
- Set counter
- Latch counter
5
• Start/stop counter with gate function
Note:
Incremental encoders and pre-assembled connecting cables
for counting and positioning functions are offered under
SIMODRIVE Sensor or Motion Connect 500.
http://www.siemens.com/simatic-technology
2 units 5m F
■ Technical specifications
Article number 6ES7350-1AH03-0AE0 Article number 6ES7350-1AH03-0AE0
FM350-1, counter mod. FM350-1, counter mod.
up to 500KHZ up to 500KHZ
Supply voltage Encoder
Auxiliary voltage 1L+, Connectable encoders
load voltage 2L+ • Incremental encoder (symmetrical) Yes; With 2 pulse trains offset by 90°
• Rated value (DC) 24 V • Incremental encoder (asymmetrical) Yes
Input current • 24 V initiator Yes
from load voltage 1L+ (without load), 40 mA • 24 V directional element Yes; 1 pulse train, 1 direction level
max.
Counter
from backplane bus 5 V DC, max. 160 mA
Number of counter inputs 1; 32 bit or ±31 bit
5 Encoder supply
5 V encoder supply
Counter input 5 V
• Terminating resistor 220 Ω
•5V Yes; 5.2 V ±2 %
• Counting frequency, max. 500 kHz
• Output current, max. 300 mA
Counter input 24 V
24 V encoder supply
• Input voltage for signal "0" -28.8 ... +5V
• 24 V Yes; 1L+ (-3 V)
• Input voltage for signal "1" +11 to +28.8V
• Output current, max. 400 mA
• Input current for signal "1", typ. 9 mA
Power loss
• Counting frequency, max. 200 kHz
Power loss, typ. 4.5 W
• Minimum pulse width 2.5 µs
Digital inputs
Connection method
Number of digital inputs 3
required front connector 1x 20-pin
Functions 1 for gate start, 1 for gate stop,
1 for setting the counter Dimensions
Input voltage Width 40 mm
• for signal "0" -28.8 ... +5V Height 125 mm
• for signal "1" +11 to +28.8V Depth 120 mm
Input current Weights
• for signal "1", typ. 9 mA Weight, approx. 250 g
Digital outputs
Number of digital outputs 2
Short-circuit protection Yes; Clocked electronically
Output voltage
• for signal "0", max. 3V
Output current
• for signal "1" rated value 0.5 A
• for signal "1" permissible range 5 mA
for 0 to 60 °C, min.
• for signal "1" permissible range 0.6 A
for 0 to 60 °C, max.
■ Overview
• 8-channel intelligent counter module for universal counting
and measuring
• To directly connect 24 V incremental encoders,
direction sensors, initiators or NAMUR encoders
• Check function with preselectable set points
(number depends on mode)
• Integrated digital outputs to output the response when the
setpoint is reached
• Operating modes:
- Continuous/single/periodic counting
- Frequency/speed measurement
- Cycle duration measurement
- Dosing 5
Note:
Incremental encoder and pre-assembled connecting cables
for counter and positioning function are offered under
SIMODRIVE Sensor and Motion Connect 500.
http://www.siemens.com/simatic-technology
■ Technical specifications
Article number 6ES7350-2AH01-0AE0 Article number 6ES7350-2AH01-0AE0
FM350-2, Counter Mod., FM350-2, Counter Mod.,
8 Channels, 20KHz 8 Channels, 20KHz
Supply voltage Encoder
Auxiliary voltage 1L+, Connectable encoders
load voltage 2L+ • Incremental encoder (asymmetrical) Yes
• Rated value (DC) 24 V • 24 V initiator Yes
Input current • 24 V directional element Yes
from load voltage L+ (without load), 150 mA • NAMUR encoder Yes; to DIN 19 234
max.
• 2-wire sensor Yes
from backplane bus 5 V DC, max. 100 mA
5
Interrupts/diagnostics/
NAMUR encoder supply status information
• 8.2 V Yes Diagnostics function Yes; Diagnostic information readable
• Short-circuit protection Yes Alarms
• Output current, max. 200 mA • Diagnostic alarm Yes; Parameterizable
Power loss • Hardware interrupt Yes; Parameterizable
Power loss, typ. 10 W Counter
Digital inputs Number of counter inputs 8; 32 bit or ±31 bit
Number of digital inputs 8 Counter input 24 V
Number of NAMUR inputs 8 • Input voltage for signal "0" -3 to +5V
Functions 1 each for gate start/ gate stop • Input voltage for signal "1" 11 to 30.2 V
Input voltage • Input current for signal "1", typ. 9 mA
• for signal "0" -3 to +5V • Counting frequency, max. 20 kHz; Incremental encoder: 10 kHz
• for signal "1" 11 to 30.2 V Connection method
Input current required front connector 1x 40-pin
• for signal "0", max. 2 mA Dimensions
(permissible quiescent current)
Width 80 mm
• for signal "1", typ. 9 mA
Height 125 mm
Input delay
(for rated value of input voltage) Depth 120 mm
• Input frequency, max. 20 kHz Weights
for standard inputs Weight, approx. 460 g
- at "0" to "1", max. 50 µs
for NAMUR inputs
- at "0" to "1", max. 50 µs
Cable length
• shielded, max. 100 m
Digital outputs
Number of digital outputs 8
Short-circuit protection Yes
Limitation of inductive shutdown L+ (-40 V)
voltage to
Output voltage
• for signal "1", min. L+ (-0.8 V)
Output current
• for signal "1" rated value 0.5 A
• for signal "0" residual current, max. 0.5 mA
Switching frequency
• with resistive load, max. 500 Hz
• with inductive load, max. 0.5 Hz
Total current of the outputs
(per group)
horizontal installation
- up to 40 °C, max. 4A
- up to 60 °C, max. 2A
all other mounting positions
- up to 40 °C, max. 2A
Cable length
• shielded, max. 600 m
Signal cables
Preassembled for SSI absolute 6FX50 ■ 2-2CC11- ■ ■ ■ ■
encoder, UL/DESINA
Preassembled for TTL encoder 6FX50 ■ 2-2CD01- ■ ■ ■ ■
6FX2001-1, UL/DESINA
Preassembled for TTL encoder 6FX50 ■ 2-2CD24- ■ ■ ■ ■
24 V, UL/DESINA
Not crimped 0
Module end crimped, 1
connector case supplied
Motor end crimped,
connector case supplied
4 5
0m 1
100 m 2
200 m 3
0m A
• Two-channel positioning module for rapid-traverse/
10 m B
creep-speed drives
20 m C
• 4 digital outputs per channel for motor control
30 m D
• Incremental or synchro-serial position decoding
40 m E
Note:
50 m F
SIMODRIVE Sensor/Motion Connect 500 feature
60 m G
position-measuring systems and preassembled connecting
cables for counting and positioning functions. 70 m H
http://www.siemens.com/simatic-technology 80 m J
90 m K
■ Ordering data Article No. 0m A
1m B
FM 351 positioning module 6ES7351-1AH02-0AE0
2m C
For rapid traverse and
creep speed drives 3m D
Front connectors 4m E
20-pin, with screw contacts 5m F
• 1 unit 6ES7392-1AJ00-0AA0 6m G
• 100 units 6ES7392-1AJ00-1AB0
7m H
20-pin, with spring-loaded contacts
• 1 unit 6ES7392-1BJ00-0AA0 8m J
• 100 units 6ES7392-1BJ00-1AB0 9m K
Bus connectors 6ES7390-0AA00-0AA0 0.0 m 0
1 unit (spare part) 0.1 m 1
Labeling strips 6ES7392-2XX00-0AA0 0.2 m 2
10 units (spare part) 0.3 m 3
Slot number label 6ES7912-0AA00-0AA0 0.4 m 4
Labeling sheets for machine See under "Accessories", 0.5 m 5
inscription page 5/257
0.6 m 6
Spare part
0.7 m 7
Shield connection element 6ES7390-5AA00-0AA0
0.8 m 8
80 mm wide,
with 2 rows for 4 terminals each
Shield connection clamp
2 units
For 2 cables 6ES7390-5AB00-0AA0
with 2 mm to 6 mm diameter
For 1 cable 6ES7390-5BA00-0AA0
with 3 mm to 8 mm diameter
For 1 cable 6ES7390-5CA00-0AA0
with 4 mm to 13 mm diameter
■ Technical specifications
Article number 6ES7351-1AH02-0AE0 Article number 6ES7351-1AH02-0AE0
FM351 positioning Mod. FM351 positioning Mod.
rapid/creep Feed rapid/creep Feed
Supply voltage Encoder
Rated value (DC) 24 V Connectable encoders
Load voltage L+ • Incremental encoder (symmetrical) Yes
• Rated value (DC) 24 V • Incremental encoder (asymmetrical) Yes
Input current • Absolute encoder (SSI) Yes
Current consumption, max. 350 mA • 2-wire sensor Yes
from backplane bus 5 V DC, max. 150 mA - permissible quiescent current 2 mA; on signal "0", max. 2 mA;
(2-wire sensor), max. on signal "1", max. 6 mA
5
Encoder supply
5 V encoder supply Encoder signals, incremental
encoder (symmetrical)
•5V Yes
• Trace mark signals A, notA, B, notB
• Output current, max. 350 mA
• Zero mark signal N, notN
• Cable length, max. 32 m
• Input voltage 5 V difference signal (phys. RS 422)
24 V encoder supply
• Input frequency, max. 0.5 MHz
• 24 V Yes
Encoder signals, incremental
• Output current, max. 400 mA; Per channel encoder (asymmetrical)
• Cable length, max. 100 m • Trace mark signals A, B
Power loss • Zero mark signal N
Power loss, typ. 7.9 W • Input frequency, max. 50 kHz; 50 kHz for 25 m cable
Digital inputs length; 25 kHz for 100 m cable
length
Number of digital inputs 8
Encoder signals,
Functions Reference cams, reversing cams, absolute encoder (SSI)
flying actual value setting, start/stop
positioning • Input signal 5 V difference signal (phys. RS 422)
Input voltage • Data signal DATA, notDATA
• Rated value (DC) 24 V • Clock signal CL, notCL
• for signal "0" -3 to +5V • Telegram length, parameterizable 13 or 25 bit
• for signal "1" +11 to +30V • Clock frequency, max. 1.5 MHz
Input current • Gray code Yes
• for signal "0", max. 2 mA • Cable length, shielded, max. 200 m; At max. 188 kHz
(permissible quiescent current) Ambient conditions
• for signal "1", typ. 6 mA Ambient temperature
Digital outputs during operation
Number of digital outputs 8 • min. 0 °C
Functions Rapid traverse, creep, run right, • max. 60 °C
run left Connection method
Short-circuit protection Yes required front connector 1x 20-pin
Output voltage Dimensions
• Rated value (DC) 24 V Width 80 mm
• for signal "1", min. UP - 0.8 V Height 125 mm
Output current Depth 120 mm
• for signal "1" permissible range 5 mA; with UPmax Weights
for 0 to 60 °C, min.
Weight, approx. 550 g
• for signal "1" permissible range 600 mA; with UPmax
for 0 to 60 °C, max.
• for signal "0" residual current, max. 0.5 mA
Signal cable
Pre-assembled for SSI absolute 6FX50 ■ 2-2CC11- ■ ■ ■ ■
encoder, UL/DESINA
Pre-assembled for TTL encoder 6FX50 ■ 2-2CD01- ■ ■ ■ ■
6FX2001-1, UL/DESINA
Pre-assembled for TTL encoder 6FX50 ■ 2-2CD24- ■ ■ ■ ■
24 V, UL/DESINA
Not crimped 0
Module end crimped, 1
connector case supplied
Motor end crimped,
connector case supplied
4 5
0m 1
100 m 2
200 m 3
0m A
• Extremely high-speed electronic cam controller
10 m B
• Low-cost alternative to mechanical cam controllers
20 m C
• 32 cam tracks, 13 onboard digital outputs for direct output of
30 m D
actions
• Incremental or synchro-serial position decoding 40 m E
50 m F
Note:
60 m G
SIMODRIVE Sensor/Motion Connect 500 feature
70 m H
position-measuring systems and preassembled connecting
cables for counting and positioning functions. 80 m J
http://www.siemens.com/simatic-technology 90 m K
0m A
■ Ordering data Article No. 1m B
2m C
FM352 electronic cam controller 6ES7352-1AH02-0AE0
3m D
Front connectors
4m E
20-pin, with screw contacts
• 1 unit 6ES7392-1AJ00-0AA0 5m F
■ Technical specifications
Article number 6ES7352-1AH02-0AE0 Article number 6ES7352-1AH02-0AE0
FM352 Electron. Cam-operated FM352 Electron. Cam-operated
Control Control
Supply voltage Encoder
Rated value (DC) 24 V Connectable encoders
Input current • Incremental encoder (symmetrical) Yes
from load voltage L+ (without load), 200 mA • Incremental encoder (asymmetrical) Yes
max. • Absolute encoder (SSI) Yes
from backplane bus 5 V DC, max. 100 mA • 2-wire sensor Yes
Encoder supply - permissible quiescent current 2 mA
5 V encoder supply (2-wire sensor), max.
5 •5V
• Output current, max.
Yes
300 mA
Encoder signals, incremental
encoder (symmetrical)
• Cable length, max. 32 m • Trace mark signals A, notA, B, notB
24 V encoder supply • Zero mark signal N, notN
• 24 V Yes • Input voltage 5 V difference signal (phys. RS 422)
• Output current, max. 300 mA • Input frequency, max. 1 MHz
• Cable length, max. 100 m Encoder signals, incremental
encoder (asymmetrical)
Power loss
• Trace mark signals A, B
Power loss, typ. 8.1 W
• Zero mark signal N
Digital inputs
• Input frequency, max. 50 kHz; 50 kHz for 25 m cable
Number of digital inputs 4 length; 25 kHz for 100 m cable
Functions Reference point switch, set floating length
actual value/length measurement, Encoder signals,
brake release, enable track output absolute encoder (SSI)
no. 3
• Data signal DATA, notDATA
Input voltage
• Clock signal CL, notCL
• Rated value (DC) 24 V
• Telegram length, parameterizable 13 or 25 bit
• for signal "0" -30 to +5 V
• Clock frequency, max. 1 MHz
• for signal "1" +11 to +30V
• Gray code Yes
Input current
• Cable length, shielded, max. 320 m; at max. 125 kHz
• for signal "0", max. 2 mA
(permissible quiescent current) Ambient conditions
• for signal "1", typ. 9 mA Ambient temperature
during operation
Digital outputs
• min. 0 °C
Number of digital outputs 13
• max. 60 °C
Functions Cam track
Connection method
Short-circuit protection Yes
required front connector 1x 20-pin
Output voltage
Dimensions
• Rated value (DC) 24 V
Width 80 mm
• for signal "1", min. UP - 0.8 V
Height 125 mm
Output current
Depth 120 mm
• for signal "1" permissible range 5 mA; with UPmax
for 0 to 60 °C, min. Weights
• for signal "1" permissible range 600 mA; with UPmax Weight, approx. 550 g
for 0 to 60 °C, max.
• for signal "0" residual current, max. 0.5 mA
FM 352-5 high-speed
Boolean processor
with sinking digital outputs 6ES7352-5AH01-0AE0
with sourcing digital outputs 6ES7352-5AH11-0AE0
Micro Memory Card
128 KB 6ES7953-8LG31-0AA0
512 KB 6ES7953-8LJ31-0AA0
2 MB 6ES7953-8LL31-0AA0
Front connector
5
40-pin, with screw contacts
• 1 unit 6ES7392-1AM00-0AA0
• 100 units 6ES7392-1AM00-1AB0
• The available set of statements comprises bit statements To SSI absolute encoders 6FX5002-2CC12- ■ ■ ■ ■
6FX2 001-5, preassembled,
(partial statement set of STEP 7), timers, counters, without Sub-D connector
frequency dividers, frequency generators, shift registers.
Length code:
• 12 integral DI / 8 integral DO.
0m 1
• 2 versions: sinking or sourcing digital outputs.
100 m 2
• 1 channel for connection of a 24-V incremental encoder,
a 5-V incremental encoder (RS 422) or an SSI absolute 200 m 3
encoder. 0m A
Micro Memory Card required for use of the FM 352-5 10 m B
Note: 20 m C
30 m D
Displacement measuring systems and precut/pre-assembled
cables for counting and positioning functions are available 40 m E
under SIMODRIVE Sensor or Motion Connect 500. 50 m F
http://www.siemens.com/simatic-technology 60 m G
70 m H
80 m J
90 m K
0m A
1m B
2m C
3m D
4m E
5m F
6m G
7m H
8m J
9m K
0.0 m 0
0.1 m 1
0.2 m 2
0.3 m 3
0.4 m 4
0.5 m 5
0.6 m 6
0.7 m 7
0.8 m 8
■ Technical specifications
Article number 6ES7352-5AH01-0AE0 6ES7352-5AH11-0AE0
FM 352-5, Boolean Processor 12DE/8DA FM 352-5 PNP, Boolean Processor 12DI/8DO
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from load voltage1L+, max. 150 mA; typ. 60 mA 150 mA; typ. 60 mA
from load voltage 2L+ (without load), 200 mA; typ. 60 mA, DI/DO supply 200 mA; typ. 60 mA, DI/DO supply
max.
from load voltage 3L+ (with encoder), 600 mA; typ. 80 mA plus encoder supply 600 mA; typ. 80 mA plus encoder supply
max.
■ Technical specifications
Article number 6ES7352-5AH01-0AE0 6ES7352-5AH11-0AE0
FM 352-5, Boolean Processor 12DE/8DA FM 352-5 PNP, Boolean Processor 12DI/8DO
Digital outputs
Number of digital outputs 8 8
Current-sinking Yes No
Current-sourcing No Yes
Short-circuit protection Yes; Overvoltage protection, thermal protection Yes; Overvoltage protection, thermal protection
Limitation of inductive shutdown 2M -45 V typ., (-40 V to -55 V); comment: 2M -45 V typ., (-40 V to -55 V); comment:
voltage to no protection against inductive kickback >55 mJ no protection against inductive kickback >55 mJ
Switching capacity of the outputs
• on lamp load, max. 5W 5W
Output voltage 5
• Rated value (DC) 24 V 24 V
• for signal "0", max. 28.8 V 28.8 V
• for signal "1", max. 0.5 V 0.5 V
Output current
• for signal "1" rated value 0.5 A; At 60 °C 0.5 A; At 60 °C
• for signal "1" permissible range 5 mA 5 mA
for 0 to 60 °C, min.
• for signal "1" permissible range 600 mA 600 mA
for 0 to 60 °C, max.
• for signal "0" residual current, max. 1 mA 1 mA
Switching frequency
• with resistive load, max. 100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A 100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A
• with inductive load, max. 2 Hz; 2 Hz at 0.5 A with external commutator diodes; 2 Hz; 2 Hz at 0.5 A with external commutator diodes;
0.5 Hz at 0.5 A without external commutator diodes 0.5 Hz at 0.5 A without external commutator diodes
• on lamp load, max. 10 Hz 10 Hz
Cable length
• shielded, max. 600 m 600 m
Encoder
Connectable encoders
• Incremental encoder (symmetrical) Yes Yes
• Incremental encoder (asymmetrical) Yes Yes
• Absolute encoder (SSI) Yes Yes
• 2-wire sensor Yes Yes
- permissible quiescent current 1.5 mA 1.5 mA
(2-wire sensor), max.
Encoder signals, incremental
encoder (symmetrical)
• Trace mark signals A, notA, B, notB A, notA, B, notB
• Zero mark signal N, notN N, notN
• Input voltage 5 V difference signal (phys. RS 422) 5 V difference signal (phys. RS 422)
• Input frequency, max. 500 kHz 500 kHz
• Cable length, shielded, max. 100 m; 100 m with 24 V supply and 500 kHz; 100 m; 100 m with 24 V supply and 500 kHz;
32 m with 5 V supply and 500 kHz 32 m with 5 V supply and 500 kHz
Encoder signals, incremental
encoder (asymmetrical)
• Trace mark signals A, B A, B
• Zero mark signal N N
• Input frequency, max. 200 kHz 200 kHz
• Cable length, shielded, max. 50 m; Cable length, HTL incremental encoder, Siemens, 50 m; Cable length, HTL incremental encoder, Siemens,
type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz,
50 m shielded, max. 50 m shielded, max.
■ Technical specifications
Article number 6ES7352-5AH01-0AE0 6ES7352-5AH11-0AE0
FM 352-5, Boolean Processor 12DE/8DA FM 352-5 PNP, Boolean Processor 12DI/8DO
Encoder signals,
absolute encoder (SSI)
• Data signal DATA, notDATA DATA, notDATA
• Clock signal CK, notCK CK, notCK
• Telegram length, parameterizable 13 or 25 bit 13 or 25 bit
• Clock frequency, max. 1 MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz 1 MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz
• Cable length, shielded, max. 320 m; At 125 kHz 320 m; At 125 kHz
• Monoflop time settable: 16/32/48/64 µs settable: 16/32/48/64 µs
• Listening mode Yes; one or two stations Yes; one or two stations
5 • Multiturn Yes; 25 bit message frame Yes; 25 bit message frame
Encoder signal evaluation
• Counting direction, forward Yes Yes
• Counting direction, backward Yes Yes
Response times
Input- to output response time 5 V input to 24 V output, 0 filter: 1 to 4 µs (typ.); 5 V input to 24 V output, 0 filter: 1 to 4 µs (typ.);
24 V input to 24 V output, 0 filter: 2 to 6 µs (typ.) 24 V input to 24 V output, 0 filter: 2 to 6 µs (typ.)
Interfaces
Point-to-point connection
• Updating times PLC interface: 1.7 ms PLC interface: 1.7 ms
Interrupts/diagnostics/
status information
Alarms
• Diagnostic alarm Yes; 1L, 2L, 3L missing; MMC error; output overload (8); Yes; 1L, 2L, 3L missing; MMC error; output overload (8);
encoder supply overload; differential wire break; encoder supply overload; differential wire break;
parameterization errror; SSI message frame overflow parameterization errror; SSI message frame overflow
• Hardware interrupt Yes; 8 available; for generation by user program Yes; 8 available; for generation by user program
Counter
Counting range, description Counting range (16-bit counters): Counting range (16-bit counters):
-32 768 to 32 767 (user-specific within this range); -32 768 to 32 767 (user-specific within this range);
counting range (32-bit counters): counting range (32-bit counters):
-2 147 483 648 to 2 147 483 647 -2 147 483 648 to 2 147 483 647
(user-specific within this range) (user-specific within this range)
Counting range, lower limit -2 147 483 648 -2 147 483 648
Counting range, upper limit 2 147 483 647 2 147 483 647
Counting mode
• Counting mode, individual Yes Yes
• Counting mode, continuous Yes Yes
• Counting mode, periodic Yes Yes
Ambient conditions
Ambient temperature
during operation
• min. 0 °C 0 °C
• max. 60 °C 60 °C
Configuration
Programming
• Program cycle time (scan) 1 µs 1 µs
Connection method
required front connector 1x 40-pin 1x 40-pin
Dimensions
Width 80 mm 80 mm
Height 125 mm 125 mm
Depth 120 mm 120 mm
Weights
Weight, approx. 434 g; Module weight: approx. 434 g 434 g; Module weight: approx. 434 g
(with 1L connection and without I/O connection or MMC); (with 1L connection and without I/O connection or MMC);
shipping weight: approx. 500 g (with bus and shipping weight: approx. 500 g (with bus and
1L connection and without I/O connection or MMC) 1L connection and without I/O connection or MMC)
■ Technical specifications
Article number 6ES7355-0VH10-0AE0 6ES7355-1VH10-0AE0
Control unit FM355C, 4 chan. Control unit FM355S, 4 chan.
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from load voltage L+ (without load), 310 mA; Typ. 260 mA 270 mA; typ. 220 mA
max.
from backplane bus 5 V DC, max. 75 mA; typ. 50 mA 75 mA; typ. 50 mA
Power loss
Power loss, typ. 6.5 W 5.5 W
Digital inputs
Number of digital inputs 8 8
Input characteristic curve Yes Yes
in accordance with IEC 61131, type 2
Input voltage
• Rated value (DC) 24 V 24 V
• for signal "0" -3 to +5V -3 to +5V
• for signal "1" 13 to 30V 13 to 30V
Input current
• for signal "1", typ. 7 mA 7 mA
Cable length
• shielded, max. 1 000 m 1 000 m
■ Technical specifications
Article number 6ES7355-0VH10-0AE0 6ES7355-1VH10-0AE0
Control unit FM355C, 4 chan. Control unit FM355S, 4 chan.
Digital outputs
Number of digital outputs 8
Short-circuit protection Yes; Electronic
Limitation of inductive shutdown L+ (-1.5 V)
voltage to
Switching capacity of the outputs
• on lamp load, max. 5W
Load resistance range
• lower limit 240 Ω
5 • upper limit 4 kΩ
Output voltage
• for signal "1", min. L+ (-2.5 V)
Output current
• for signal "1" rated value 100 mA
• for signal "1" permissible range 5 mA
for 0 to 60 °C, min.
• for signal "1" permissible range 150 mA
for 0 to 60 °C, max.
• for signal "0" residual current, max. 0.5 mA
Switching frequency
• with resistive load, max. 100 Hz
• with inductive load, max. 0.5 Hz
• on lamp load, max. 100 Hz
Total current of the outputs
(per group)
all mounting positions
- up to 60 °C, max. 400 mA
Cable length
• shielded, max. 1 000 m
Analog inputs
Number of analog inputs 4 4
permissible input voltage for voltage 30 V 30 V
input (destruction limit), max.
permissible input current for current 40 mA 40 mA
input (destruction limit), max.
Input ranges (rated values),
voltages
• 0 to +10 V Yes Yes
• -1.75 V to +11.75 V Yes Yes
• -80 mV to +80 mV Yes Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes Yes
• 0 to 23.5 mA Yes Yes
• -3.5 mA to +23.5 mA Yes Yes
• 4 mA to 20 mA Yes Yes
Input ranges (rated values),
thermocouples
• Type B Yes Yes
• Type J Yes Yes
• Type K Yes Yes
• Type R Yes Yes
• Type S Yes Yes
Input ranges (rated values),
resistance thermometer
• Pt 100 Yes Yes
■ Technical specifications
Article number 6ES7355-0VH10-0AE0 6ES7355-1VH10-0AE0
Control unit FM355C, 4 chan. Control unit FM355S, 4 chan.
Thermocouple (TC)
Temperature compensation
- internal temperature Yes Yes
compensation
- external temperature Yes Yes
compensation with Pt100
Characteristic linearization
• parameterizable Yes Yes
- for thermocouples Type B, J, K, R, S Type B, J, K, R, S
- for resistance thermometer
Cable length
Pt100 (standard) Pt100 (standard)
5
• shielded, max. 200 m; 50 m at 80 mV and thermocouples 200 m; 50 m at 80 mV and thermocouples
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, 25 mA
max.
Current output, no-load voltage, max. 18 V
Output ranges, voltage
• 0 to 10 V Yes
• -10 V to +10 V Yes
Output ranges, current
• 0 to 20 mA Yes
• 4 mA to 20 mA Yes
Connection of actuators
• for voltage output Yes
two-wire connection
• for current output Yes
two-wire connection
Load impedance
(in rated range of output)
• with voltage outputs, min. 1 kΩ
• with voltage outputs, capacitive 1 µF
load, max.
• with current outputs, max. 500 Ω
• with current outputs, inductive load, 1 mH
max.
Cable length
• shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 14 bit; 12 bit or 14 bit, parameterizable 14 bit; 12 bit or 14 bit, parameterizable
(bit including sign), max.
Analog value generation
for the outputs
Settling time
• for resistive load 0.1 ms
• for capacitive load 3.3 ms
• for inductive load 0.5 ms
■ Technical specifications
Article number 6ES7355-0VH10-0AE0 6ES7355-1VH10-0AE0
Control unit FM355C, 4 chan. Control unit FM355S, 4 chan.
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes
• for current measurement Yes Yes
as 4-wire transducer
Connectable encoders
• 2-wire sensor Yes Yes
- permissible quiescent current 1.5 mA 1.5 mA
(2-wire sensor), max.
5 Errors/accuracies
Operational error limit in overall
temperature range
• Voltage, relative to input range, (+/-) 0.6 %; ±0.6 to ±1% 0.6 %; ±0.6 to ±1%
• Current, relative to input range, (+/-) 0.6 %; ±0.6 to ±1% 0.6 %; ±0.6 to ±1%
• Resistance thermometer, 0.6 %; ±0.6 to ±1% 0.6 %; ±0.6 to ±1%
relative to input range, (+/-)
• Voltage, relative to output range, 0.5 %
(+/-)
• Current, relative to output range, 0.6 %
(+/-)
Basic error limit (operational limit at
25 °C)
• Voltage, relative to input range, (+/-) 0.4 %; 80 mV: ±0.6 %; 250 to 1 000 mV: ±0.4 %; 0.4 %; 80 mV: ±0.6 %; 250 to 1 000 mV: ±0.4 %;
2.5 to 10 V: ±0.6 %; 3.2 to 20 mA: ±0.5 % 2.5 to 10 V: ±0.6 %; 3.2 to 20 mA: ±0.5 %
• Current, relative to input range, (+/-) 0.4 %; ±0.4 to ±0.6 % 0.4 %; ±0.4 to ±0.6 %
• Resistance thermometer, 0.4 %; ±0.4 to ±0.6 % 0.4 %; ±0.4 to ±0.6 %
relative to input range, (+/-)
• Voltage, relative to output range, 0.3 %
(+/-)
• Current, relative to output range, 0.5 %
(+/-)
Interrupts/diagnostics/
status information
Substitute values connectable Yes; Parameterizable Yes; Parameterizable
Integrated Functions
Control technology
• Number of closed-loop controllers 4 4
Connection method
required front connector 2x 20-pin 2x 20-pin
Dimensions
Width 80 mm 80 mm
Height 125 mm 125 mm
Depth 120 mm 120 mm
Weights
Weight, approx. 470 g 470 g
FM 355-2 C 6ES7355-2CH00-0AE0
temperature controller module
With 4 analog outputs for
4 continuous-action controllers
FM 355-2 S 6ES7355-2SH00-0AE0
temperature controller module
With 8 digital outputs for 4 step or
pulse controllers
Front connector
20-pin, with screw contacts
• 1 unit 6ES7392-1AJ00-0AA0
• 100 units
20-pin, with spring-loaded contacts
6ES7392-1AJ00-1AB0
5
• 1 unit 6ES7392-1BJ00-0AA0
• 100 units 6ES7392-1BJ00-1AB0
Bus connectors 6ES7390-0AA00-0AA0
1 unit (spare part)
■ Technical specifications
Article number 6ES7355-2CH00-0AE0 6ES7355-2SH00-0AE0
TEMP.-Control unit FM355-2C, 4 chan. TEMP.-Control unit FM355-2S, 4 chan.
Supply voltage
Load voltage L+
• Rated value (DC) 24 V 24 V
Input current
from load voltage L+ (without load), 310 mA; Typ. 260 mA 270 mA; typ. 220 mA
max.
from backplane bus 5 V DC, max. 75 mA; typ. 50 mA 75 mA; typ. 50 mA
Power loss
Power loss, typ. 6.5 W 5.5 W
Digital inputs
Number of digital inputs 8 8
Input characteristic curve Yes Yes
in accordance with IEC 61131, type 2
Input voltage
• Rated value (DC) 24 V 24 V
• for signal "0" -3 to +5V -3 to +5V
• for signal "1" 13 to 30V 13 to 30V
Input current
• for signal "1", typ. 7 mA 7 mA
Cable length
• shielded, max. 1 000 m 1 000 m
■ Technical specifications
Article number 6ES7355-2CH00-0AE0 6ES7355-2SH00-0AE0
TEMP.-Control unit FM355-2C, 4 chan. TEMP.-Control unit FM355-2S, 4 chan.
Digital outputs
Number of digital outputs 8
Short-circuit protection Yes; Electronic
Limitation of inductive shutdown L+ (-1.5 V)
voltage to
Switching capacity of the outputs
• on lamp load, max. 5W
Load resistance range
• lower limit 240 Ω
5 • upper limit 4 kΩ
Output voltage
• for signal "1", min. L+ (-2.5 V)
Output current
• for signal "1" rated value 0.1 A
• for signal "1" permissible range 5 mA
for 0 to 60 °C, min.
• for signal "1" permissible range 150 mA
for 0 to 60 °C, max.
• for signal "0" residual current, max. 0.5 mA
Switching frequency
• with resistive load, max. 100 Hz
• with inductive load, max. 0.5 Hz
• on lamp load, max. 100 Hz
Total current of the outputs
(per group)
all mounting positions
- up to 60 °C, max. 400 mA
Cable length
• shielded, max. 1 000 m
Analog inputs
Number of analog inputs 4 4
permissible input voltage for voltage 20 V 20 V
input (destruction limit), max.
permissible input current for current 40 mA 40 mA
input (destruction limit), max.
Input ranges (rated values),
voltages
• 0 to +10 V Yes Yes
• -1.75 V to +11.75 V Yes Yes
Input ranges (rated values), currents
• 0 to 20 mA Yes Yes
• 0 to 23.5 mA Yes Yes
• -3.5 mA to +23.5 mA Yes Yes
• 4 mA to 20 mA Yes Yes
Input ranges (rated values),
thermocouples
• Type B Yes Yes
• Type E Yes Yes
• Type J Yes Yes
• Type K Yes Yes
• Type R Yes Yes
• Type S Yes Yes
Input ranges (rated values),
resistance thermometer
• Pt 100 Yes Yes
■ Technical specifications
Article number 6ES7355-2CH00-0AE0 6ES7355-2SH00-0AE0
TEMP.-Control unit FM355-2C, 4 chan. TEMP.-Control unit FM355-2S, 4 chan.
Thermocouple (TC)
Temperature compensation
- internal temperature Yes Yes
compensation
- external temperature Yes Yes
compensation with Pt100
Characteristic linearization
• parameterizable Yes Yes
- for thermocouples Type B, E, J, K, R, S Type B, E, J, K, R, S
- for resistance thermometer
Cable length
Pt100 (standard) Pt100 (standard)
5
• shielded, max. 200 m; 50 m at 80 mV and thermocouples 200 m; 50 m at 80 mV and thermocouples
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, 25 mA
max.
Current output, no-load voltage, max. 18 V
Output ranges, voltage
• 0 to 10 V Yes
• -10 V to +10 V Yes
Output ranges, current
• 0 to 20 mA Yes
• 4 mA to 20 mA Yes
Connection of actuators
• for voltage output Yes
two-wire connection
• for current output Yes
two-wire connection
Load impedance
(in rated range of output)
• with voltage outputs, min. 1 kΩ
• with voltage outputs, 1 µF
capacitive load, max.
• with current outputs, max. 500 Ω
• with current outputs, inductive load, 1 mH
max.
Cable length
• shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value generation
for the inputs
Integration and conversion time/
resolution per channel
• Resolution with overrange 14 bit 14 bit
(bit including sign), max.
Analog value generation
for the outputs
Settling time
• for resistive load 0.1 ms
• for capacitive load 3.3 ms
• for inductive load 0.5 ms
Encoder
Connection of signal encoders
• for voltage measurement Yes Yes
• for current measurement Yes Yes
as 4-wire transducer
Connectable encoders
• 2-wire sensor Yes Yes
- permissible quiescent current 1.5 mA 1.5 mA
(2-wire sensor), max.
■ Technical specifications
Article number 6ES7355-2CH00-0AE0 6ES7355-2SH00-0AE0
TEMP.-Control unit FM355-2C, 4 chan. TEMP.-Control unit FM355-2S, 4 chan.
Errors/accuracies
Operational error limit in overall
temperature range
• Voltage, relative to input range, (+/-) 0.6 %; ±0.6 to ±0.7 % 0.06 %; ±0.06 to ±0.7%
• Current, relative to input range, (+/-) 0.6 %; ±0.6 to ±0.7 % 0.06 %; ±0.06 to ±0.7%
• Resistance thermometer, 0.6 %; ±0.6 to ±0.7 % 0.06 %; ±0.06 to ±0.7%
relative to input range, (+/-)
• Voltage, relative to output range, 0.5 %
(+/-)
Signal cable
Pre-assembled for SSI absolute 6FX5002-2CC12- ■ ■ ■ ■
encoder 6FX2001-5, without
D-sub connector, UL/DESINA
0m 1
100 m 2
200 m 3
0m A
10 m B
20 m C 5
30 m D
40 m E
50 m F
60 m G
70 m H
• Interface between max. 3 absolute-value sensors (SSI) and
the CPU 80 m J
■ Technical specifications
Article number 6ES7338-4BC01-0AB0 Article number 6ES7338-4BC01-0AB0
SM 338, f. 3 SSI encoders SM 338, f. 3 SSI encoders
Supply voltage Encoder
Load voltage L+ Number of connectable encoders, 3
• Rated value (DC) 24 V max.
Input current Connectable encoders
from load voltage L+ (without load), 100 mA • Absolute encoder (SSI) Yes
max. • 2-wire sensor Yes
from backplane bus 5 V DC, max. 160 mA Encoder signals,
24 V encoder supply absolute encoder (SSI)
• 24 V Yes; L+ (-0.8 V) • Cable length, shielded, max. 320 m; 320 m at 125 kHz;
0m 1
100 m 2
200 m
0m
3
A
5
10 m B
20 m C
30 m D
40 m E
• For connecting up to 4 drives with analog setpoint interface or 50 m F
pulse-direction interface to a controller
60 m G
• Operation with isochronous PROFIBUS DP
70 m H
• Connectable drives:
- Electrical drives 80 m J
- Hydraulic drives 90 m K
- Stepper drives 0m A
• Can be used with: 1m B
- SIMATIC CPU 41x-2 DP, CPU 31x-2 DP, CPU 31xT-2 DP,
WinAC RTX 2008 2m C
- SIMOTION C2xx, SIMOTION P320-4, SIMOTION D4x5-2 3m D
• Can also be used with external encoders 4m E
5m F
6m G
7m H
8m J
9m K
0.0 m 0
0.1 m 1
0.2 m 2
0.3 m 3
0.4 m 4
0.5 m 5
0.6 m 6
0.7 m 7
0.8 m 8
■ Technical specifications
Article number 6ES7174-0AA10-0AA0 Article number 6ES7174-0AA10-0AA0
IM 174 IM 174
for connecting analog Drives for connecting analog Drives
Supply voltage Digital outputs
Rated value (DC) 24 V Number of digital outputs 8
Input current Short-circuit protection Yes
Current consumption, max. 500 mA Switching capacity of the outputs
from backplane bus 5 V DC, max. 100 mA • with resistive load, max. 1A
Encoder supply • on lamp load, max. 30 W
5 V encoder supply Output voltage
•5V Yes • Rated value (DC) 24 V; L+
5 • Output current, max. 1.2 A • for signal "1", min. L+ (-3 V)
• Cable length, max. 25 m • for signal "1", max. 3V
24 V encoder supply Output current
• 24 V Yes • for signal "1" permissible range 5 mA
• Output current, max. 1.4 A for 0 to 55 °C, min.
• Cable length, max. 100 m • for signal "1" permissible range 300 mA
for 0 to 55 °C, max.
Absolute encoder (SSI) encoder
supply • for signal "0" residual current, max. 0.4 mA
• Absolute encoder (SSI) Yes Switching frequency
• Short-circuit protection Yes • with resistive load, max. 500 Hz
Power loss • with inductive load, max. 0.5 Hz
Power loss, typ. 12 W Relay outputs
Digital inputs • Number of relay outputs 4
Number of digital inputs 10 • Number of operating cycles, max. 50 000
Input voltage Switching capacity of contacts
• for signal "0" -3 to +5V - with resistive load, max. 1A
• for signal "1" +11 to +30V Cable length
Input current • shielded, max. 600 m
• for signal "0", max. 2 mA Analog outputs
(permissible quiescent current) Number of analog outputs 4
• for signal "1", typ. 8 mA Output ranges, voltage
Input delay • -10 V to +10 V Yes
(for rated value of input voltage) Analog value generation
for standard inputs for the outputs
- at "0" to "1", min. 15 µs Integration and conversion time/
Cable length resolution per channel
• shielded, max. 100 m • Resolution with overrange 15 bit
(bit including sign), max.
■ Technical specifications
Article number 6ES7174-0AA10-0AA0 Article number 6ES7174-0AA10-0AA0
IM 174 IM 174
for connecting analog Drives for connecting analog Drives
Encoder Drive interface
Number of connectable encoders, 4 Number of drive interfaces 4
max. Analog drive
Connectable encoders Setpoint signal
• Incremental encoder (symmetrical) Yes - Short-circuit proof Yes; max. 45 mA, min. 3.3 kOhm load
• Absolute encoder (SSI) Yes impedance
• 2-wire sensor Yes - Rated voltage range -10.5 V to +10.5 V
- permissible quiescent current 2 mA - Output current -3 to +3 mA
(2-wire sensor), max.
Encoder signals, incremental
Output controller enable
- Number of relay contacts 4
5
encoder (symmetrical)
- Switching voltage, max. 30 V
• Trace mark signals A, notA, B, notB
- Switching current, max. 1A
• Zero mark signal N, notN
- Switching capacity, max. 30 V·A
• Input voltage 5 V difference signal (phys. RS 422)
- Number of switching cycles, min. 50 000; at 30 V DC, 1 A
• Input frequency, max. 1 MHz
- Cable length, shielded, max. 35 m
• Cable length, shielded, max. 35 m; 35 m at max. 500 kHz;
10 m at max. 1 MHz Stepper drive
Encoder signals, • Differential output voltage, min. 2 V; R = 100 Ohm
absolute encoder (SSI) • Differential output voltage 1 V; For I = -20 mA
• Input signal 5 V difference signal (phys. RS 422) for signal "0", max.
• Data signal DATA, notDATA • Differential output voltage 3.7 V; 3.7 V at I = -20 mA;
for signal "1", min. 4.5 V at I = -100 µA,
• Clock signal CL, notCL
• Load resistance, min. 55 Ω
• Telegram length, parameterizable 13, 21, 24 bit
• Output current, max. 60 mA
• Clock frequency, max. 1.5 MHz; 187.5 KHz 1.5 MHz
(parameterizable) • Pulse frequency 750 kHz
• Binary code Yes • Cable length, shielded, max. 50 m; in hybrid operation with
analog axes 35 m, in asymmetrical
• Gray code Yes transmission 10 m
• Cable length, shielded, max. 250 m; 250 m at 187.5 kHz, Ambient conditions
10 m at 1.5 MHz
Ambient temperature
Interrupts/diagnostics/ during operation
status information
• min. 0 °C
Alarms
• max. 55 °C
• Diagnostic alarm Yes
Connection method
required front connector 40-pin
Dimensions
Width 160 mm
Height 125 mm
Depth 118 mm
Weights
Weight, approx. 1 kg
■ Overview
SIWAREX U is a versatile weighing module for all simple
weighing and force measuring tasks. The compact module
can be integrated into SIMATIC automation systems without
any problems. Complete data access is then possible via the
SIMATIC.
■ Technical specifications
SIWAREX U SIWAREX U
Integration in automation systems Load cell powering
• S7-300 Direct integration Supply voltage Us (rated value) 6 V DC1)
• S7-1500 Through ET 200M
• S7-400 (H) Through ET 200M Max. supply current ≤ 150 mA per channel
• PCS 7 (H) Through ET 200M Permissible load resistance
• Automation systems Through ET 200M • RLmin > 40 Ω per channel
from other vendors • RLmax < 4 010 Ω
• Stand-alone Possible with IM 153-1
(without SIMATIC CPU) With Ex(i) interface
• RLmin > 87 Ω per channel
Communication interfaces • SIMATIC S7 (P bus) • RLmax < 4 010 Ω
• RS 232
5 Connection of remote display
• TTY
Gross, channel 1, 2 or
Permissible load cell
characteristic
Up to 4 mV/V
(via serial TTY interface) default value 1, 2 Max. distance of load cells • 500 m2)
• 150/500 m for gas group IIC
Scale adjustment Through SIMATIC (P bus) or PC • 500 m2) for gas group IIB
using SIWATOOL U (RS 232) (see SIWAREX IS Manual)
Measuring properties Intrinsically-safe load cell Optional (Ex interface)
Error limit according to DIN 1319-1 0.05% powering with SIWAREX IS
of full-scale value at 20 °C ± 10 K Auxiliary power supply
(68 °F ± 10 K)
Rated voltage 24 V DC
Internal resolution ADC 65 535
Max. power consumption 150 mA (single-channel) / 240 mA
Data format weight values 2 bytes (fixed-point) (dual-channel)
Number of measurements/second 50 Current consumption ≤ 100 mA
Digital filter 0.05 ... 5 Hz (in 7 steps), on backplane bus
mean value filter Certification ATEX 95, FM, cULUS Haz. Loc.
Weighing functions IP degree of protection to IP20
Weight values Gross DIN EN 60529; IEC 60529
Limit values 2 (min./max.) Climatic requirements
Zero-setting function Per command Tmin (IND) ... Tmax (IND)
(operating temperature)
Load cells Strain gauges in 4-wire or • Horizontal installation 0 ... +60 °C (32 ... 140 °F)
6-wire system • Vertical installation 0 ... +40 °C (32 ... 104 °F)
EMC requirements according to According to NAMUR NE21, Part 1;
EN 61326
Dimensions 40 × 125 × 130 mm
(1.58 × 4.92 × 5.12 inch)
1)
Load cell supply changed to 6 V DC as compared to 7MH4601-1AA01 and
7MH4601-1BA01.
2)
Possible up to 1 000 m under certain conditions when using the
recommended cable (accessories).
■ Overview
SIWAREX FTA (Flexible Technology, Automatic Weighing
Instrument) is a versatile and flexible weighing module for
industrial use. It can be used in both non-automatic and
automatic weighing operation, for example the production of
mixtures, and for filling, loading, monitoring and bag filling.
It has the corresponding scale approvals and is also suitable for
weighing systems requiring official calibration.
The SIWAREX FTA function module is integrated in
SIMATIC S7/PCS 7 and uses the features of this modern
automation system, such as integrated communication,
diagnostics and configuration tools.
5
5 • RS 232 interface
S7 DIN rail
Cable Li2Y 1 x 2 x 0.75 ST +
2 x (2 x 0.34 ST) – CY
• 160 mm (6.30 inch) 6ES7390-1AB60-0AA0 For connecting SIWAREX electronic
• 480 mm (18.90 inch) 6ES7390-1AE80-0AA0 weighing systems to junction box
(JB), extension box (EB) and
• 530 mm (20.87 inch) 6ES7390-1AF30-0AA0 Ex interface or between two EBs.
• 830 mm (32.68 inch) 6ES7390-1AJ30-0AA0 For permanent installation.
• 2 000 mm (78.74 inch) 6ES7390-1BC00-0AA0 Occasional bending is possible.
MMC memory 7MH4900-2AY21 External diameter:
For data recording up to 32 MB, approx. 10.8 mm (0.43 inch)
only for legal-for-trade applications Permissible ambient temperature
R76, R51 and R107 -40 ... +80 °C (-40 ... +176 °F)
Remote displays (option) Sold by the meter.
• Sheath color: orange 7MH4702-8AG
The Siebert S102 and S302
remote digital displays can be • For hazardous atmospheres. 7MH4702-8AF
directly connected to the Sheath color: blue.
SIWAREX FTA via an Commissioning
RS 485 interface.
Siebert Industrieelektronik GmbH Commissioning charge 9LA1110-8SN50-0AA0
PO Box 1180 for one static scale with
D-66565 Eppelborn SIWAREX module
Tel.: +49 6806/980-0 (Flat charge for travel and setup
Fax: +49 6806/980-999 must be ordered separately)
Internet: Scope:
https://www.siebert-group.com/en/ • Recording of data
Detailed information is available • Checking of mechanical
from the manufacturer. installation of the scale
• Checking of electrical wiring and
SIWAREX JB junction box, 7MH5001-0AA20 function
aluminum housing • Static adjustment of the scale
For connecting up to 4 load cells Requirements:
in parallel, and for connecting • Mechanical design functional
several junction boxes • Modules electrically wired and
SIWAREX JB junction box, 7MH5001-0AA00 tested
stainless steel housing • Calibration weights available
• Free access to scale
For connecting up to 4 load cells
in parallel. Flat charge for travel and setup 9LA1110-8RA10-0AA0
in Germany
SIWAREX JB junction box, 7MH5001-0AA01
stainless steel housing (ATEX)
For parallel connection of up to
4 load cells (for zone allocation,
see manual or type-examination
certificate).
■ Technical specifications
SIWAREX FTA SIWAREX FTA
Use in automation systems Max. distance of load cells
S7-300 Directly or via ET 200M When using the recommended
cable:
S7-1500 Through ET 200M
Standard 1 000 m (3 280 ft)
S7-400 (H) Through ET 200M
In hazardous area 1)
PCS 7 (H) Through ET 200M
• For gases of group IIC 300 m (984 ft)
Communication interfaces • For gases of group IIB 1000 m (3 280 ft)
S7 Through backplane bus Connection to load cells Optionally via SIWAREX IS Ex interface
RS 232 For SIWATOOL or printer connection in Ex zone 1
RS 485
Module parameterization
For remote display or digital load cell
Using SIMATIC S7
Ex approvals zone 2 and safety
Auxiliary power supply
ATEX 95, FM, cULUS Haz. Loc.
5
Using SIWATOOL FTA software Rated voltage 24 V DC
(RS 232) Max. power consumption 500 mA
Measuring properties Current consumption Typ. 55 mA
EU type approval as non automatic 3 x 6 000 d ≥ 0.5 μV/e on backplane bus
weighing instrument, trade class III Inputs/outputs
Internal resolution 16 million parts Digital inputs 7 DI electrically isolated
Internal/external updating rate 400/100 Hz Digital outputs 8 DO electrically isolated
Several parameterizable Critically dampened, Bessel, Counter input Up to 10 kHz
digital filters Butterworth (0.05 ... 20 Hz),
mean-value filter Analog output
• Current range 0/4 ... 20 mA
Weighing functions
• Updating rate 100 Hz
Non automatic weighing instrument OIML R76
Approvals EU type approval (CE, OIML R76)
Automatic weighing machine OIML R51, R61, R107
EU prototype test according to MID
Load cells Strain gauges in 4-wire or 6-wire (OIML R51, R61, R107)
system
Degree of protection IP20
3 characteristic value ranges 1, 2 or 4 mV/V according to EN 60529; IEC 60529
Load cell powering Climatic requirements
Supply voltage US (rated value) 10.3 V DC Tmin (IND) ... Tmax (IND)
(operating temperature)
Max. supply current 184 mA • Horizontal installation -10 ... 60 °C (14 ... 140 °F)
Permissible load cell resistance • Vertical installation -10 ... 40 °C (14 ... 104 °F)
• RLmin > 56 Ω EMC requirements EN 61326, EN 45501, NAMUR NE21,
> 87 Ω with Ex interface Part 1
• RLmax ≤ 4 010 Ω Dimensions 80 × 125 × 130 mm
(3.15 × 4.92 × 5.12 inch)
Weight 600 g (0.44 lb)
1)
For further details, see Ex interface, type SIWAREX IS.
■ Overview
The SIWAREX FTC (Flexible Technology for Continuous
Weighing) is a versatile and flexible weighing module for belt
scales, loss-in-weight feeders and solids flowmeters.
It can also be used to record weights and measure force.
The SIWAREX FTC function module is integrated in
SIMATIC S7/PCS 7 and uses the features of this modern
automation system, such as integrated communication,
diagnostics and configuration tools.
5
The Siebert S102 and S302 remote -40 ... +80 °C (-40 ... +176 °F)
digital displays can be directly
Sold by the meter.
connected to the SIWAREX FTC
via an RS 485 interface. • Sheath color: orange 7MH4702-8AG
(not suitable for belt scale mode) • For hazardous atmospheres. 7MH4702-8AF
Sheath color: blue.
Siebert Industrieelektronik GmbH
PO Box 1180 Commissioning
D-66565 Eppelborn
Tel.: +49 6806/980-0 Commissioning charge for one 9LA1110-8SM50-0AA0
Fax: +49 6806/980-999 belt scale with SIWAREX module
Internet: (Flat charge for travel and setup
https://www.siebert-group.com/en/ must be ordered separately)
Detailed information is available Scope:
from the manufacturer. • Recording of data
• Checking of mechanical
SIWAREX JB junction box, 7MH5001-0AA20 installation of the scale
aluminum housing • Checking of electrical wiring
For connecting up to 4 load cells and function
in parallel, and for connecting • Dynamic adjustment of the scale
multiple junction boxes.
Requirements:
SIWAREX JB junction box, 7MH5001-0AA00 • Mechanical design functional
stainless steel housing • Modules electrically wired and
For connecting up to 4 load cells tested
in parallel. • Calibration weights available
• Free access to scale
SIWAREX JB junction box, 7MH5001-0AA01
stainless steel housing (ATEX) Flat charge for travel and setup 9LA1110-8RA10-0AA0
in Germany
For parallel connection of up to
4 load cells (for zone allocation,
see manual or type-examination
certificate).
Ex interface SIWAREX IS
For intrinsically safe connection
of load cells. With ATEX approval
(not UL/FM). Suitable for
SIWAREX electronic weighing
systems. Compatibility of load cells
must be checked separately.
• With short-circuit current 7MH4710-5BA
< 199 mA DC
• With short-circuit current 7MH4710-5CA
< 137 mA DC
■ Technical specifications
SIWAREX FTC SIWAREX FTC
Use in automation systems Max. distance of load cells
S7-300 Directly or via ET 200M When using the recommended cable:
S7-1500 Through ET 200M Standard 1 000 m (3 280 ft)
S7-400 (H) Through ET 200M In hazardous area 1)
PCS 7 (H) Through ET 200M • For gases of group IIC 300 m (984 ft)
• For gases of group IIB 1 000 m (3 280 ft)
Communication interfaces
Connection to load cells Optionally via
S7 Through backplane bus in Ex zone 1 SIWAREX IS Ex interface
RS 232 For SIWATOOL or printer connection Ex approvals zone 2 and safety ATEX 95, FM, cULUS Haz. Loc.
5 RS 485
Module parameterization
For remote display or digital load cell Auxiliary power supply
Rated voltage 24 V DC
Using SIMATIC S7 Max. power consumption 500 mA
Using SIWATOOL FTC software Current consumption Typ. 55 mA
(RS 232) on backplane bus
Measuring properties Inputs/outputs
Accuracy according to EN 45501 3 x 6 000 d ≥ 0.5 μV/e Digital inputs 7, electrically isolated
Internal resolution +/- 8 million parts Digital outputs 8, electrically isolated
Internal/external updating rate 400/100 Hz Counter input Up to 10 kHz
Several parameterizable Critically dampened, Bessel, Analog output
digital filters Butterworth (0.05 ... 20 Hz), • Current range 0/4 ... 20 mA
mean-value filter
• Updating rate 100 Hz
Weighing functions • Non automatic weighing instrument,
force measurement Degree of protection according to IP20
EN 60529; IEC 60529
• Belt scale
Climatic requirements
• Loss-in-weight scale Tmin (IND) ... Tmax (IND)
• Solids flowmeters (operating temperature)
• Horizontal installation -10 ... 60 °C (14 ... 140 °F)
Load cells Strain gauges in 4-wire or 6-wire
system • Vertical installation -10 ... 40 °C (14 ... 104 °F)
3 characteristic value ranges 1, 2 or 4 mV/V EMC requirements EN 61326, EN 45501, NAMUR NE21,
Part 1
Load cell powering
Dimensions 80 × 125 × 130 mm
Supply voltage US (rated value) 10.3 V DC (3.15 × 4.92 × 5.12 inch)
Max. supply current 184 mA Weight 600 g (0.44 lb)
Permissible load cell resistance
• RLmin > 56 Ω
> 87 Ω with Ex interface
• RLmax ≤ 4 010 Ω
1) For further details, see Ex interface, type SIWAREX IS.
■ Overview
• Single-channel, intelligent counter module for simple counting
tasks
• For direct connection of incremental encoders
• Comparison function with 2 definable comparison values
• Integrated digital outputs for output of the response on
reaching the comparison value
• Operating modes:
- Continuous counting
- Single counting
- Periodic counting
• Special functions:
- Set counter
- Latch counter
5
• Start/stop counter by gate function
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
Accessories Documentation
■ Technical specifications
Article number 6AG1350-1AH03-2AE0 Article number 6AG1350-1AH03-2AE0
Based on 6ES7350-1AH03-0AE0 Based on 6ES7350-1AH03-0AE0
SIPLUS S7-300 FM350-1 SIPLUS S7-300 FM350-1
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold and fungal
during operation according to EN 60721-3-6 spores (excluding fauna);
• min. -25 °C; = Tmin Class 6B3 on request
• max. 60 °C; = Tmax - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
Altitude during operation (severity degree 3); *
relating to sea level
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
• Installation altitude above sea level, 5 000 m according to EN 60721-3-6
5 max.
• Ambient air temperature- Tmin ... Tmax at
Usage in industrial process
technology
barometric pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // - Against chemically active Yes; Class 3
Tmin ... (Tmax - 10 K) at substances acc. to EN 60654-4 (excluding trichlorethylene)
795 hPa ... 658 hPa - Environmental conditions for Yes; Level GX group A/B
(+2 000 m ... +3 500 m) // process, measuring and control (excluding trichlorethylene;
Tmin ... (Tmax -20 K) at systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
658 hPa ... 540 hPa the limits of EN 60721-3-3 class 3C4
(+3 500 m ... +5 000 m) permissible); level LC3 (salt spray)
Relative humidity and level LB3 (oil)
• With condensation, 100 %; RH incl. condensation/frost Remark
tested in accordance (no commissioning under - Note regarding classification * The supplied plug covers must
with IEC 60068-2-38, max. condensation conditions) of environmental conditions remain in place over the unused
Resistance acc. to EN 60721, EN 60654-4 interfaces during operation!
and ANSI/ISA-71.04
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of
fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl.
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Overview
• 8-channel intelligent counter module for universal counting
and measuring tasks
• For the direct connection of 24 V incremental encoders,
directional encoders, initiators or NAMUR encoders
• Comparison function with predefined comparison values
(number depending on operating mode)
• Integrated digital outputs for output of the response on
reaching the comparison value
• Operating modes:
- Continuous / single / periodic counting
- Frequency and speed control
- Period measurement
- Dosing 5
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
■ Technical specifications
Article number 6AG1350-2AH01-4AE0 Article number 6AG1350-2AH01-4AE0
Based on 6ES7350-2AH01-0AE0 Based on 6ES7350-2AH01-0AE0
SIPLUS S7-300 FM350-2 SIPLUS S7-300 FM350-2
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold and fungal
during operation according to EN 60721-3-6 spores (excluding fauna); Class 6B3
• min. 0 °C; = Tmin on request
• max. 60 °C; = Tmax - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
Altitude during operation (severity degree 3); *
relating to sea level
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
• Installation altitude above sea level, 5 000 m according to EN 60721-3-6
5 max.
• Ambient air temperature- Tmin ... Tmax at
Usage in industrial process
technology
barometric pressure-altitude 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // - Against chemically active Yes; Class 3
Tmin ... (Tmax - 10 K) at substances acc. to EN 60654-4 (excluding trichlorethylene)
795 hPa ... 658 hPa - Environmental conditions for Yes; Level GX group A/B
(+2 000 m ... +3 500 m) // process, measuring and control (excluding trichlorethylene;
Tmin ... (Tmax -20 K) at systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
658 hPa ... 540 hPa the limits of EN 60721-3-3 class 3C4
(+3 500 m ... +5 000 m) permissible); level LC3 (salt spray)
Relative humidity and level LB3 (oil)
• With condensation, tested in accor- 100 %; RH incl. condensation/frost Remark
dance with IEC 60068-2-38, max. (no commissioning under condensa- - Note regarding classification * The supplied plug covers must
tion conditions) of environmental conditions remain in place over the unused
Resistance acc. to EN 60721, EN 60654-4 interfaces during operation!
and ANSI/ISA-71.04
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry
according to EN 60721-3-3 rot spores (with the exception of
fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl.
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
■ Overview
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
SIPLUS SIWAREX U electronic weighing system
Article No. 6AG1 950-2AA01-4AA0
Article No. based on 7MH4 950-2AA01
Range of ambient temperature 0 ... +60 °C
Conformal coating Coating of the printed circuit boards
Technical data
and the electronic components
The technical data of the standard
5
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity 100%, condensation/frost
permissible. No commissioning when
SIPLUS SIWAREX U electronic weighing system condensation present
SIPLUS SIWAREX U is a flexible weighing module for all simple For technical documentation on SIPLUS, see:
weighing and force measuring tasks. The compact module
can be integrated into SIPLUS automation systems without any http://www.siemens.com/siplus-extreme
problems.
5
SIWAREX PCS 7 AddOn Library 7MH4900-1AK61
Cable Li2Y 1 x 2 x 0.75 ST + 7MH4702-8AF for PCS 7 V8.x and V9.0
2 x (2 x 0.34 ST) – CY, • Supports PROFINET
blue sheath APL faceplates and
For connecting the junction box function blocks for:
(JB) or extension box (EB) in a • SIWAREX U
potentially explosive atmosphere to • SIWAREX FTA
the Ex interface (Ex I), • SIWAREX FTC_B (belt scales)
for fixed laying, occasional bending • SIWAREX WP321
permitted, blue PVC insulating Classic faceplate and
sheath, approx. 10.8 mm function block for:
(0.43 inch) outer diameter, • SIWAREX FTC_L
for ambient temperature (Loss-in-weight)
-40 ... +80 °C (-40 ... +176 °F)
Documentation
SIMATIC Manual Collection 6ES7998-8XC01-8YE0
Electronic manuals on DVD,
multi-language:
LOGO!, SIMADYN,
SIMATIC bus components,
SIMATIC C7,
SIMATIC Distributed I/O,
SIMATIC HMI, SIMATIC Sensors,
SIMATIC NET, SIMATIC PC-based
Automation, SIMATIC PCS 7,
SIMATIC PG/PC, SIMATIC S7,
SIMATIC Software, SIMATIC TDC
SIMATIC Manual Collection 6ES7998-8XC01-8YE2
update service for 1 year
Current Manual Collection DVD and
the three subsequent updates
■ Overview
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
corresponding standard products. SIPLUS extreme specific
information has been added.
SIPLUS SIWAREX FTA
Article No. 6AG1900-2AA01-4AA0
Article No. based on 7MH4900-2AA01
Ambient temperature range -25 … +70 °C
Conformal coating Coating of the printed circuit boards
Technical specifications
and the electronic components
The technical specifications of the
5
standard product apply, except for
the ambient conditions.
Ambient conditions
Relative humidity 100%, condensation/frost
permissible. No commissioning
SIPLUS SIWAREX FTA (Flexible Technology, Automatic under condensation conditions.
Weighing Instrument) is a versatile and flexible weighing module Biologically active substances, Class 3B2 mold, fungal and dry
for industrial use. It can be used in both non-automatic and compliance with EN 60721-3-3 rot spores (excluding fauna).
automatic weighing operation, for example the production of The supplied plug covers must
mixtures, and for filling, loading, monitoring and bag filling. remain in place over the unused
interfaces during operation!
It has the corresponding scale approvals and is also suitable for Chemically active substances, Class 3C4 incl. salt spray
legal-for-trade weighing systems. compliance with EN 60721-3-3 in accordance with EN60068-2-52
(degree of severity 3). The supplied
The SIPLUS SIWAREX FTA function module is integrated in plug covers must remain in place
SIMATIC S7/PCS7 and uses the features of this modern over the unused interfaces during
automation system, such as integrated communication, operation!
diagnostics and configuration tools. Mechanically active substances, Class 3S4 incl. sand, dust.
compliance with EN 60721-3-3 The supplied plug covers must
remain in place over the unused
interfaces during operation!
CP 340 6ES7340-1AH02-0AE0
communications module
With one RS 232 C (V.24) interface
RS 232 connecting cable
For linking to SIMATIC S7
5m 6ES7902-1AB00-0AA0
10 m 6ES7902-1AC00-0AA0
15 m 6ES7902-1AD00-0AA0
CP 340 6ES7340-1BH02-0AE0
communications module
With one 20 mA (TTY) interface 5
20 mA (TTY) connecting cable
For linking to SIMATIC S7
5m 6ES7902-2AB00-0AA0
• The economical complete solution for serial communication 10 m 6ES7902-2AC00-0AA0
via point-to-point links. 50 m 6ES7902-2AG00-0AA0
• 3 versions with different transmission interfaces: CP 340 6ES7340-1CH02-0AE0
- RS 232C (V.24) communications module
- 20 mA (TTY)
With one
- RS 422/RS 485 (X.27) RS 422/485 (X.27) interface
• Implemented protocols: RS 422/485 connecting cable
- ASCII
- 3964 (R) (not for RS 485) For linking to SIMATIC S7
- Printer driver 5m 6ES7902-3AB00-0AA0
• Simple parameterization via a parameterization tool integrated 10 m 6ES7902-3AC00-0AA0
into STEP 7
50 m 6ES7902-3AG00-0AA0
■ Technical specifications
Article number 6ES7340-1AH02-0AE0 6ES7340-1BH02-0AE0 6ES7340-1CH02-0AE0
CP340 w. RS232C interface(V.24) CP340 w. 20MA interface(TTY) CP340 w. RS422/485 interface
General information
Product type designation CP 340 CP 340 CP 340
Supply voltage
Rated value (DC)
• 24 V DC No; Power supply via backplane bus No; Power supply via backplane bus No; Power supply via backplane bus
5V 5V 5V
Input current
from backplane bus 5 V DC, max. 165 mA 190 mA 165 mA
Power loss
Power loss, typ. 0.6 W 0.85 W 0.6 W
Interfaces
Interfaces/bus type RS 232C (V.24) 20 mA (TTY)
Number of interfaces 1; Isolated 1; Isolated 1; Isolated
Transmission rate, min. 2.4 kbit/s 2.4 kbit/s 2.4 kbit/s
Transmission rate, max. 19.2 kbit/s 19.2 kbit/s 19.2 kbit/s
Point-to-point connection
• Cable length, max. 15 m 1 000 m; 100 m active, 1 000 m pas- 1 200 m
sive
• supported printers HP-Deskjet, HP-Laserjet, HP-Deskjet, HP-Laserjet, HP-Deskjet, HP-Laserjet,
IBM-Proprinter, user-defined IBM-Proprinter, user-defined IBM-Proprinter, user-defined
• Connector type 9-pin sub D connector 9-pin sub D socket 15-pin sub D socket
Integrated protocol driver
- 3964 (R) Yes Yes Yes
- ASCII Yes Yes Yes
- RK 512 No No No
- customer-specific drivers No No No
reloadable
Telegram length, max.
- 3964 (R) 1 024 byte 1 024 byte 1 024 byte
- ASCII 1 024 byte 1 024 byte 1 024 byte
■ Technical specifications
Article number 6ES7340-1AH02-0AE0 6ES7340-1BH02-0AE0 6ES7340-1CH02-0AE0
CP340 w. RS232C interface(V.24) CP340 w. 20MA interface(TTY) CP340 w. RS422/485 interface
Transmission rate, 20 mA (TTY)
- with 3964 (R) protocol, max. 19.2 kbit/s
- with ASCII protocol, max. 9.6 kbit/s
- with printer driver, max. 9.6 kbit/s
Transmission rate, RS 422/485
- with 3964 (R) protocol, max. 19.2 kbit/s
- with ASCII protocol, max. 9.6 kbit/s
- with printer driver, max. 9.6 kbit/s
CP 341 6ES7341-1AH02-0AE0
communications module
With one RS 232 C (V.24) interface
RS 232 connecting cable
For linking to SIMATIC S7
5m 6ES7902-1AB00-0AA0
10 m 6ES7902-1AC00-0AA0
15 m 6ES7902-1AD00-0AA0
CP 341 6ES7341-1BH02-0AE0
communications module
With one 20 mA (TTY) interface 5
20 mA (TTY) connecting cable
For linking to SIMATIC S7
5m 6ES7902-2AB00-0AA0
10 m 6ES7902-2AC00-0AA0
• For quick, high-performance serial data exchange 50 m 6ES7902-2AG00-0AA0
via point-to-point coupling CP 341 6ES7341-1CH02-0AE0
• 3 versions with different transmission physics: communications module
- RS 232C (V.24), With one
- 20 mA (TTY), RS 422/485 (X.27) interface
- RS 422/RS 485 (X.27) RS 422/485 connecting cable
• Implemented protocols: ASCII, 3964 (R), RK 512 For linking to SIMATIC S7
• The following protocols can also be loaded: Modbus RTU 5m 6ES7902-3AB00-0AA0
• Simple parameter assignment using tool integrated in STEP 7 10 m 6ES7902-3AC00-0AA0
50 m 6ES7902-3AG00-0AA0
Loadable drivers for CP 341
Modbus master (RTU format)
• Single license 6ES7870-1AA01-0YA0
• Single license, without software or 6ES7870-1AA01-0YA1
documentation
Modbus slave (RTU format)
• Single license 6ES7870-1AB01-0YA0
• Single license, without software or 6ES7870-1AB01-0YA1
documentation
■ Technical specifications
Article number 6ES7341-1AH02-0AE0 6ES7341-1BH02-0AE0 6ES7341-1CH02-0AE0
CP 341 RS232C (V.24) CP341 20mA-Interface (TTY) CP341 RS422/485-Interface
General information
Product type designation CP 341 CP 341 CP 341
Supply voltage
Rated value (DC)
• 24 V DC Yes Yes Yes
Input current
from supply voltage L+, max. 100 mA 100 mA 100 mA
from backplane bus 5 V DC, max. 70 mA 70 mA 70 mA
Power loss
Power loss, typ. 1.6 W 1.6 W 1.6 W
Interfaces
Interfaces/bus type RS 232C (V.24) 20 mA (TTY)
Number of interfaces 1; Isolated 1; Isolated 1; Isolated
Transmission rate, min. 0.3 kbit/s 0.3 kbit/s 0.3 kbit/s
Transmission rate, max. 115.2 kbit/s 19.2 kbit/s 115.2 kbit/s
■ Technical specifications
Article number 6ES7341-1AH02-0AE0 6ES7341-1BH02-0AE0 6ES7341-1CH02-0AE0
CP 341 RS232C (V.24) CP341 20mA-Interface (TTY) CP341 RS422/485-Interface
Point-to-point connection
• Cable length, max. 15 m 1 000 m 1 200 m
• supported printers Serial printers Serial printers Serial printers
• Connector type 9-pin sub D connector 9-pin sub D socket 15-pin sub D socket
Integrated protocol driver
- 3964 (R) Yes Yes Yes; not with RS 485
- ASCII Yes Yes Yes
- RK 512 Yes Yes Yes; not with RS 485
■ Overview
• Drivers for Modbus protocol with RTU message format;
communication as master or slave
• Downloadable onto CP 341 and CP 441-2
(6ES7 441-2AA05-0AE0)
■ Technical specifications
Parameterization software Loadable drivers for CP 441-2 and Modbus slave
CP 341
• Modbus protocol with RTU format
Type of license Simple license, copy license
• Master/slave coupling:
Target system SIMATIC CP 341, SIMATIC CP 441-2 SIMATIC S7 is slave
• Function codes implemented:
Technical specifications Modbus Master 01, 02, 03, 04, 05, 06, 08, 15, 16
• Modbus protocol with RTU format • No V.24 control and signal line
• Master/slave coupling: • CRC polynomial: x16 + x15 + x2 +1
SIMATIC S7 is master
• Interfaces:
• Function codes implemented: TTY (20 mA), V.24 (RS 232C),
01, 02, 03, 04, 05, 06, 07, 08, 11, 12, X.27 (RS 422/485) 2-wire or 4-wire
5 15, 16
• No V.24 control and signal lines
• Communications FB 180, instance
DB 180 (use of a multi-instance)
• CRC polynomial: x16 + x15 + x2 +1 • Conversion of the Modbus data
• Interfaces: address to S7 data areas.
TTY (20 mA); V.24 (RS 232 C); Data areas which can be
X.27 (RS 422/485) 2-wire or 4-wire processed: DB, bit memories,
outputs, inputs, timers, counters
• Receive mailbox specified on BRCV
• Character delay time 3.5 characters
• Character delay time 3.5 characters or multiple thereof
or multiple thereof
Adjustable parameters • Transmission rate 300 bit/s up to
• Broadcast message possible 76800 bit/s (TTY up to 19200 bit/s)
Adjustable parameters • Transmission rate 300 bit/s up to • Character frame
76800 bit/s (TTY up to 19200 bit/s)
• Slave address of CP (1 to 255)
• Character frame
• With/without RS 485 operation
• With/without RS 485 operation for 2-wire connection
for 2-wire connections
• With/without modem operation
• With/without modem operation (ignore smudge characters)
(ignore smudge characters)
• Factor for the character delay time
• Response monitoring time 100 ms 1-10
to 25.5 s in steps of 100 ms
• Number of work DB
• Factor for the character delay time (for FB processing)
1-10
• Enabling of memory areas
• Default setting of receive line when for writing by the master
using the X.27 interface module
• Default setting of receive line when
using the X.27 interface module
• Conversion of Modbus addresses to
S7 data areas
■ Overview
Function
The CP 343-2P / CP 343-2 supports all specified functions of the
extended AS-Interface Specification V3.0.
The CP 343-2P / CP 343-2 each occupy 16 bytes in the
I/O address area of the SIMATIC S7-300. The digital I/O data of
the standard slaves and A slaves is saved in this area.
The digital I/O data of the B slaves and the analog I/O data can
be accessed with the S7 system functions for read/write data
records.
If required, master calls can be performed with the command
interface, e.g. read/write parameters, read/write configuration.
For more information, see 5
https://support.industry.siemens.com/cs/ww/en/view/51678777.
Notes on security
In order to protect plants, systems, machines and networks
against cyber threats, it is necessary to implement – and
continuously maintain – a holistic, state-of-the-art industrial
The CP 343-2P communications processor is the AS-Interface security concept. Siemens products and solutions only
master for the SIMATIC S7-300 and the ET 200M distributed I/O represent one component of such a concept.
station, with user-friendly parameterizing options.
For more information on Industrial Security, see
The CP 343-2 is the basic version of the module. http://www.siemens.com/industrialsecurity.
The CP 343-2P / CP 343-2 has the following characteristics: Configuration
• As many as 62 AS-Interface slaves can be connected
All connected AS-Interface slaves are configured at the press of
• Integrated analog value transmission a button. No further configuration of the CP is required.
• Supports all AS-Interface master functions according to the
AS-Interface Specification V3.0 Additionally for CP 343-2P
• Status displays of operating states and indication of the The CP 343-2P also supports configuring of the AS-Interface
readiness for operation of connected slaves by means of network with STEP 7 V5.2 and higher. Specifying the AS-i config-
LEDs in the front panel uration in HW-Config facilitates the setting of slave parameters
and documentation of the plant. Uploading the ACTUAL config-
• Fault indications (including AS-Interface voltage fault, uration of an already configured AS-Interface network is also
configuration fault) by means of LEDs in the front panel. supported. The saved configuration cannot be overwritten at the
• Compact enclosure in the design of the SIMATIC S7-300 press of a button and is therefore tamper-proof.
• Suitable for AS-Interface with 30-V voltage and AS-i Power24V
(from product version 2/firmware version 3.1)
• Additionally for CP 343-2P: Supports the configuration
of the AS-Interface-network with STEP 7 V5.2 and higher
Design
The CP 343-2P / CP 343-2 is connected like an I/O module to the
S7-300. It has:
• Two terminal connections for connecting the AS-Interface
cable directly.
• LEDs in the front panel for indicating the operating state and
functional readiness of all connected and active slaves
• Pushbuttons for switching over the master operating state
and for adopting the existing ACTUAL configuration of the
AS-i slave as the TARGET configuration
CP 342-5 6GK7342-5DA03-0XE0
communications processor
Communications processor
for electrical connection of
SIMATIC S7-300 to PROFIBUS
at up to 12 Mbit/s, with electronic
manual on CD-ROM
Accessories
PROFIBUS FastConnect RS 485
connection plug
With 90° cable outlet;
insulation displacement technology,
max. transmission rate 12 Mbit/s
• Without programming device 6ES7972-0BA52-0XA0 5
interface
• With programming device 6ES7972-0BB52-0XA0
interface
PROFIBUS bus connector IP20
With connection to PPI, MPI,
'30 '36 )06 3*23 66 PROFIBUS
• Without programming device 6ES7972-0BA12-0XA0
interface
*B,.B;;B
■ Technical specifications
Article number 6GK7342-5DA03-0XE0 Article number 6GK7342-5DA03-0XE0
product type designation CP 342-5 product type designation CP 342-5
transfer rate supply voltage, current
transfer rate consumption, power loss
• at the 1st interface 9.6 kbit/s ... 12 Mbit/s type of voltage of the supply voltage DC
acc. to PROFIBUS supply voltage 1 from backplane bus 5 V
interfaces supply voltage external 24 V
number of interfaces 0 supply voltage external 24 V
acc. to Industrial Ethernet at DC rated value
number of electrical connections relative positive tolerance 20 %
• at the 1st interface 1 at DC at 24 V
acc. to PROFIBUS relative negative tolerance 15 %
• for power supply 1 at DC at 24 V
type of electrical connection consumed current
• at the 1st interface 9-pin Sub-D socket (RS485) • from backplane bus at DC 0.15 A
acc. to PROFIBUS at 5 V typical
• for power supply 4-pole terminal block • from external supply voltage 0.25 A
at DC at 24 V typical
power loss [W] 6.75 W
■ Technical specifications
Article number 6GK7342-5DA03-0XE0 Article number 6GK7342-5DA03-0XE0
product type designation CP 342-5 product type designation CP 342-5
ambient conditions performance data PROFIBUS DP
ambient temperature service as DP master
• during operation 0 ... 60 °C • DPV0 Yes
• during storage -40 ... +70 °C number of DP slaves
• during transport -40 ... +70 °C • on DP master operable 124
relative humidity data volume
• at 25 °C without condensation 95 % • of the address range of the inputs 2 160 byte
during operation maximum as DP master total
protection class IP IP20 • of the address range of the outputs 2 160 byte
5 design, dimensions and weights as DP master total
• of the address range of the inputs 244 byte
module format Compact module S7-300
single width per DP slave
width 40 mm • of the address range of the outputs 244 byte
per DP slave
height 125 mm
• of the address range of the 240 byte
depth 120 mm diagnostic data per DP slave
net weight 0.3 kg service as DP slave
product features, product functions, • DPV0 Yes
product components general
data volume
number of units
• of the address range of the inputs 240 byte
• per CPU maximum 4 as DP slave total
performance data • of the address range of the outputs 240 byte
open communication as DP slave total
number of possible connections for 16 performance data
open communication by means of S7 communication
SEND/RECEIVE blocks maximum
number of possible connections
data volume for S7 communication
• as user data per connection for 240 byte • maximum 16
open communication by means of
SEND/RECEIVE blocks maximum performance data
multi-protocol mode
number of active connections
with multi-protocol mode
• without DP maximum 32
• with DP maximum 28
performance data telecontrol
protocol is supported
• TCP/IP No
product functions management,
configuration, engineering
configuration software
• required STEP 7 V5.1 SP2 or higher /
STEP 7 Professional V12 (TIA Portal)
or higher
standards, specifications, approvals
hazardous environments
certificate of suitability CCC Yes
for hazardous zone according
to GB standard
■ Technical specifications
Article number 6GK7342-5DF00-0XE0 Article number 6GK7342-5DF00-0XE0
product type designation CP 342-5 FO product type designation CP 342-5 FO
transfer rate supply voltage, current
transfer rate consumption, power loss
• at the 1st interface 9.6 kbit/s ... 12 Mbit/s type of voltage of the supply voltage DC
acc. to PROFIBUS supply voltage 1 from backplane bus 5 V
interfaces supply voltage 24 V
number of interfaces 0 supply voltage external 24 V
acc. to Industrial Ethernet supply voltage external 24 V
number of electrical connections at DC rated value
• for power supply 1 relative positive tolerance 20 %
number of optical interfaces 2 at DC at 24 V
at the 1st interface acc. to PROFIBUS relative negative tolerance 15 %
design of the optical interface Duplex socket at DC at 24 V
at the 1st interface acc. to PROFIBUS consumed current
type of electrical connection • from backplane bus at DC 0.15 A
• for power supply 4-pole terminal block at 5 V typical
• from external supply voltage 0.25 A
at DC at 24 V typical
power loss [W] 6W
■ Technical specifications
Article number 6GK7342-5DF00-0XE0 Article number 6GK7342-5DF00-0XE0
product type designation CP 342-5 FO product type designation CP 342-5 FO
ambient conditions performance data PROFIBUS DP
ambient temperature service as DP master
• during operation 0 ... 60 °C • DPV0 Yes
• during storage -40 ... +70 °C number of DP slaves
• during transport -40 ... +70 °C • on DP master operable 124
relative humidity data volume
• at 25 °C without condensation 95 % • of the address range of the inputs 2 160 byte
during operation maximum as DP master total
protection class IP IP20 • of the address range of the outputs 2 160 byte
5 design, dimensions and weights as DP master total
• of the address range of the inputs 244 byte
module format Compact module
per DP slave
width 40 mm
• of the address range of the outputs 244 byte
height 125 mm per DP slave
depth 120 mm • of the address range of the 240 byte
net weight 0.3 kg diagnostic data per DP slave
fastening method service as DP slave
• S7-300 rail mounting Yes • DPV0 Yes
product features, product functions, data volume
product components general • of the address range of the inputs 240 byte
number of units as DP slave total
• per CPU maximum 4 • of the address range of the outputs 240 byte
as DP slave total
wire length
performance data
• for PCF FOC maximum 300 m S7 communication
• for POF FOC maximum 50 m number of possible connections
performance data for S7 communication
open communication • maximum 16
number of possible connections for 16 performance data
open communication by means of multi-protocol mode
SEND/RECEIVE blocks maximum
number of active connections
data volume with multi-protocol mode
• as user data per connection for 240 byte • without DP maximum 32
open communication by means of
SEND/RECEIVE blocks maximum • with DP maximum 28
performance data telecontrol
protocol is supported
• TCP/IP No
product functions management,
configuration, engineering
configuration software
• required STEP 7 V5.1 SP2 or higher /
STEP 7 Professional V12 (TIA Portal)
or higher
standards, specifications, approvals
hazardous environments
certificate of suitability CCC Yes
for hazardous zone according to
GB standard
CP 343-5 6GK7343-5FA01-0XE0
communications processor
Communications processor for
connection of S7-300 to PROFIBUS,
FMS, open communication,
PG/OP and S7 communication;
with electronic manual on CD-ROM
Accessories
STEP 7 Version 5.7
Target system:
SIMATIC S7-300/-400, SIMATIC C7
Requirements:
Windows 10 Professional/
Enterprise, Windows Server 2016, 5
Windows Server 2019
Type of delivery:
English, German, French, Spanish,
Italian; including license key on
USB flash drive,
with electronic documentation
documentation as download;
consignee email address required
for delivery
Connection of SIMATIC S7-300 to PROFIBUS at up to 12 Mbit/s Rental license for 50 hours; 6ES7810-4CC12-0YA6
(including 45.45 Kbit/s) software and documentation on
DVD, license key on USB flash
• Communication services:
- PG/OP communication Rental license for 50 hours, 6ES7810-4CE12-0YB6
- S7 communication download1); software, license key
and documentation as download;
- Open communication (SEND/RECEIVE) consignee email address required
- PROFIBUS FMS for delivery
• Easy configuration and programming over PROFIBUS Upgrade floating license 6ES7810-4CC12-0YE5
• Can be easily integrated into the S7-300 system V5.3...5.6 to V5.7; on DVD
■ Technical specifications
Article number 6GK7343-5FA01-0XE0 Article number 6GK7343-5FA01-0XE0
product type designation CP 343-5 product type designation CP 343-5
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-300
• at the 1st interface 9.6 kbit/s ... 12 Mbit/s single width
acc. to PROFIBUS width 40 mm
interfaces height 125 mm
number of interfaces 0 depth 120 mm
acc. to Industrial Ethernet net weight 0.3 kg
number of electrical connections fastening method
• at the 1st interface 1 • S7-300 rail mounting Yes
5 acc. to PROFIBUS
• for power supply 1
product features, product functions,
product components general
type of electrical connection number of units
• at the 1st interface 9-pin Sub-D socket (RS485) • per CPU maximum 4
acc. to PROFIBUS
performance data
• for power supply 4-pole terminal block open communication
supply voltage, current number of possible connections for 16
consumption, power loss open communication by means of
type of voltage of the supply voltage DC SEND/RECEIVE blocks maximum
supply voltage 1 from backplane bus 5 V data volume
supply voltage 24 V • as user data per connection for 240 byte
supply voltage external 24 V open communication by means of
SEND/RECEIVE blocks maximum
supply voltage external 24 V
at DC rated value performance data FMS functions
relative positive tolerance 20 % number of possible connections for 16
at DC at 24 V FMS connection maximum
relative negative tolerance 15 % data volume of the variables
at DC at 24 V • for READ job maximum 237 byte
consumed current • for WRITE and REPORT job 233 byte
• from backplane bus at DC at 5 V typ- 0.15 A maximum
ical number of variables
• from external supply voltage at DC at 0.25 A • configurable from server to 256
24 V typical FMS partner
power loss [W] 5W • loadable from server to FMS partner 256
ambient conditions performance data
ambient temperature S7 communication
• during operation 0 ... 60 °C number of possible connections for
S7 communication
• during storage -40 ... +70 °C
• maximum 16
• during transport -40 ... +70 °C
performance data multi-protocol
relative humidity mode
• at 25 °C without condensation 95 % number of active connections 48
during operation maximum with multi-protocol mode
protection class IP IP20 performance data telecontrol
protocol is supported
• TCP/IP No
product functions management,
configuration, engineering
configuration software
• required STEP 7 V5.1 SP3 or higher and
NCM S7 for PROFIBUS
standards, specifications, approvals
hazardous environments
certificate of suitability CCC Yes
for hazardous zone according to
GB standard
6GK1901-1BB30-0AA0
• 1 pack = 10 units 6GK1901-1BB30-0AB0
• 1 pack = 50 units 6GK1901-1BB30-0AE0
■ Technical specifications
Article number 6GK7343-1CX10-0XE0 Article number 6GK7343-1CX10-0XE0
product type designation CP 343-1 Lean product type designation CP 343-1 Lean
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-300
• at the 1st interface 10 ... 100 Mbit/s single width
interfaces width 40 mm
number of interfaces 2 height 125 mm
acc. to Industrial Ethernet depth 120 mm
number of electrical connections net weight 0.22 kg
• at the 1st interface 2 fastening method
acc. to Industrial Ethernet • S7-300 rail mounting Yes
5 • for power supply
type of electrical connection
1 performance data
open communication
• of Industrial Ethernet interface RJ45 port number of possible connections for 8
• at the 1st interface RJ45 port open communication by means of
acc. to Industrial Ethernet SEND/RECEIVE blocks maximum
type of electrical connection data volume
• for power supply 2-pole plugable terminal block • as user data per 8 Kibyte
ISO on TCP connection for open
supply voltage, current communication by means of
consumption, power loss SEND/RECEIVE blocks maximum
type of voltage of the supply voltage DC • as user data per TCP connection for 8 Kibyte
supply voltage 1 from backplane bus 5 V open communication by means of
SEND/RECEIVE blocks maximum
supply voltage 24 V
• as user data per UDP connection for 2 Kibyte
supply voltage external 24 V open IE communication by means of
supply voltage external 24 V SEND/RECEIVE blocks maximum
at DC rated value number of Multicast stations 8
relative positive tolerance 20 % performance data
at DC at 24 V S7 communication
relative negative tolerance 15 % number of possible connections
at DC at 24 V for S7 communication
consumed current • maximum 4
• from backplane bus at DC 0.2 A service
at 5 V typical
• of SIMATIC communication Yes
• from external supply voltage 0.16 A as server
at DC at 24 V typical
performance data
• from external supply voltage 0.2 A multi-protocol mode
at DC at 24 V maximum
number of active connections 12
power loss [W] 5.8 W with multi-protocol mode
ambient conditions performance data
ambient temperature PROFINET communication
as PN IO controller
• for vertical installation 0 ... 40 °C
during operation product function No
PROFINET IO controller
• for horizontally arranged busbars 0 ... 60 °C
during operation
• during storage -40 ... +70 °C
• during transport -40 ... +70 °C
relative humidity
• at 25 °C without condensation 95 %
during operation maximum
protection class IP IP20
■ Technical specifications
Article number 6GK7343-1CX10-0XE0 Article number 6GK7343-1CX10-0XE0
product type designation CP 343-1 Lean product type designation CP 343-1 Lean
performance data product functions diagnostics
PROFINET communication product function Yes
as PN IO device web-based diagnostics
product function PROFINET IO device Yes product functions switch
data volume product feature switch Yes
• as user data for input variables 512 byte product function
as PROFINET IO device maximum
• switch-managed No
• as user data for output variables 512 byte
as PROFINET IO device maximum • with IRT PROFINET IO switch No
• configuration with STEP 7 Yes
5
• as user data for input variables 240 byte
for each sub-module as product functions redundancy
PROFINET IO device
product function
• as user data for output variables 240 byte
for each sub-module as • ring redundancy Yes
PROFINET IO device • redundancy manager No
• as user data for the consistency area 240 byte protocol is supported Yes
for each sub-module Media Redundancy Protocol (MRP)
number of submodules 32 product functions security
per PROFINET IO-Device
product function
performance data telecontrol
• password protection for No
protocol is supported Web applications
• TCP/IP Yes • ACL - IP-based Yes
product functions management, • ACL - IP-based for PLC/routing No
configuration, engineering
• switch-off of non-required services Yes
product function MIB support Yes
• blocking of communication Yes
protocol is supported via physical ports
• SNMP v1 Yes • log file for unauthorized access No
• DCP Yes product functions time
• LLDP Yes product function SICLOCK support Yes
configuration software product function pass on time Yes
• required STEP 7 V5.4 or higher / synchronization
STEP 7 Professional V11 (TIA Portal) protocol is supported
or higher
• NTP Yes
identification & maintenance function
standards, specifications, approvals
• I&M0 - device-specific information Yes hazardous environments
• I&M1 – higher level designation/ Yes certificate of suitability CCC Yes
location designation for hazardous zone according to
GB standard
■ Overview
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5
UDP
G_IK10_XX_10147
Communications processor for connecting a
SIMATIC S7-300/SINUMERIK 840D powerline to
Industrial Ethernet networks, also as PROFINET IO Controller
or IO Device.
The CP supports:
• PG/OP communication
5 • S7 communication
• Open communication (SEND/RECEIVE)
• PROFINET communication
■ Technical specifications
Article number 6GK7343-1EX30-0XE0 Article number 6GK7343-1EX30-0XE0
product type designation CP 343-1 product type designation CP 343-1
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-300
• at the 1st interface 10 ... 100 Mbit/s single width
interfaces width 40 mm
number of interfaces 2 height 125 mm
acc. to Industrial Ethernet depth 120 mm
number of electrical connections net weight 0.22 kg
• at the 1st interface 2 fastening method
acc. to Industrial Ethernet • S7-300 rail mounting Yes
• for power supply
type of electrical connection
1 performance data
open communication
5
• of Industrial Ethernet interface RJ45 port number of possible connections for 16
• at the 1st interface RJ45 port open communication by means of
acc. to Industrial Ethernet SEND/RECEIVE blocks maximum
type of electrical connection data volume
• for power supply 2-pole plugable terminal block • as user data per ISO connection for 8 Kibyte
open communication by means of
supply voltage, current SEND/RECEIVE blocks maximum
consumption, power loss
• as user data per 8 Kibyte
type of voltage of the supply voltage DC ISO on TCP connection for open
supply voltage 1 from backplane bus 5 V communication by means of
SEND/RECEIVE blocks maximum
supply voltage 24 V
• as user data per TCP connection for 8 Kibyte
supply voltage external 24 V open communication by means of
supply voltage external 24 V SEND/RECEIVE blocks maximum
at DC rated value • as user data per UDP connection for 2 Kibyte
relative positive tolerance 20 % open IE communication by means of
at DC at 24 V SEND/RECEIVE blocks maximum
relative negative tolerance 15 % number of Multicast stations 16
at DC at 24 V performance data
consumed current S7 communication
• from backplane bus at DC 0.2 A number of possible connections for
at 5 V typical S7 communication
• from external supply voltage 0.16 A • maximum 16
at DC at 24 V typical performance data
• from external supply voltage 0.2 A multi-protocol mode
at DC at 24 V maximum number of active connections 32
power loss [W] 5.8 W with multi-protocol mode
ambient conditions performance data
PROFINET communication
ambient temperature
as PN IO controller
• for vertical installation 0 ... 40 °C
number of PN IO devices on 32
during operation
PROFINET IO controller operable total
• for horizontally arranged busbars 0 ... 60 °C
number of external PN IO lines 1
during operation
with PROFINET per rack
• during storage -40 ... +70 °C
data volume
• during transport -40 ... +70 °C
• as user data for input variables as 1 Kibyte
relative humidity PROFINET IO controller maximum
• at 25 °C without condensation 95 % • as user data for output variables as 1 Kibyte
during operation maximum PROFINET IO controller maximum
protection class IP IP20 • as user data for input variables 1 433 byte
per PN IO device as
PROFINET IO controller maximum
• as user data for output variables 1 433 byte
per PN IO device as
PROFINET IO controller maximum
• as user data for input variables per 240 byte
PN IO device for each sub-module
as PROFINET IO controller
maximum
• as user data for output variables per 240 byte
PN IO device for each sub-module
as PROFINET IO controller
maximum
■ Technical specifications
Article number 6GK7343-1EX30-0XE0 Article number 6GK7343-1EX30-0XE0
product type designation CP 343-1 product type designation CP 343-1
performance data product functions diagnostics
PROFINET communication product function Yes
as PN IO device web-based diagnostics
product function PROFINET IO device Yes product functions switch
data volume product feature switch Yes
• as user data for input variables as 512 byte product function
PROFINET IO device maximum
• switch-managed No
• as user data for output variables as 512 byte
PROFINET IO device maximum • with IRT PROFINET IO switch Yes
• configuration with STEP 7 Yes
5
• as user data for input variables 240 byte
for each sub-module as product functions redundancy
PROFINET IO device
product function
• as user data for output variables 240 byte
for each sub-module as • ring redundancy Yes
PROFINET IO device • redundancy manager No
• as user data for the consistency area 240 byte protocol is supported Yes
for each sub-module Media Redundancy Protocol (MRP)
number of submodules 32 product functions security
per PROFINET IO-Device
product function
performance data telecontrol
• password protection for No
protocol is supported Web applications
• TCP/IP Yes • ACL - IP-based Yes
product functions management, • ACL - IP-based for PLC/routing No
configuration, engineering
• switch-off of non-required services Yes
product function MIB support Yes
• blocking of communication Yes
protocol is supported via physical ports
• SNMP v1 Yes • log file for unauthorized access No
• DCP Yes product functions time
• LLDP Yes product function SICLOCK support Yes
configuration software product function pass on time Yes
• required STEP 7 V5.4 SP2 or higher / synchronization
STEP 7 Professional V11 (TIA Portal) protocol is supported
or higher
• NTP Yes
identification & maintenance function
standards, specifications, approvals
• I&M0 - device-specific information Yes hazardous environments
• I&M1 – higher level designation/ Yes certificate of suitability CCC Yes
location designation for hazardous zone according to
GB standard
■ Overview
Communications processor for connecting the
SIMATIC S7-300/SINUMERIK 840D powerline to
Industrial Ethernet networks, also as PROFINET IO controller
and IO device.
The CP supports:
• PG/OP communication
• S7 communication
• Open communication (SEND/RECEIVE)
• PROFINET communication
• IT communication
• Security functionality, firewall and VPN 5
In addition, the CP 343-1 Advanced provides email functions and
allows users to create their own Web pages - ideal support for
maintenance and quality assurance. The Internet functions such
as FTP even allow connection to the most diverse PC-based sys-
tems. This CP is therefore the bridge between the field level and
the management level for the S7-300. The CP 343-1 Advanced
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 connects seamlessly to the security structures of the office and
UDP IT world.
G_IK10_XX_10145
■ Technical specifications
Article number 6GK7343-1GX31-0XE0 Article number 6GK7343-1GX31-0XE0
product type designation CP 343-1 Advanced product type designation CP 343-1 Advanced
transfer rate ambient conditions
transfer rate ambient temperature
• at the 1st interface 10 ... 1 000 Mbit/s • for vertical installation 0 ... 40 °C
• at the 2nd interface 10 ... 100 Mbit/s during operation
interfaces • for horizontally arranged busbars 0 ... 60 °C
during operation
number of interface 3
acc. to Industrial Ethernet • during storage -40 ... +70 °C
number of electrical connections • during transport -40 ... +70 °C
• at the 1st interface 1 relative humidity
acc. to Industrial Ethernet • at 25 °C without condensation 95 %
• at the 2nd interface 2 during operation maximum
acc. to Industrial Ethernet protection class IP IP20
• for power supply 1 design, dimensions and weights
type of electrical connection module format Compact module
• at the 1st interface RJ45 port width 80 mm
acc. to Industrial Ethernet height 125 mm
• at the 2nd interface RJ45 port depth 120 mm
acc. to Industrial Ethernet
net weight 0.8 kg
type of electrical connection
fastening method
• for power supply 2-pole plugable terminal block
• S7-300 rail mounting Yes
design of the removable storage
performance data
• C-PLUG Yes open communication
supply voltage, current number of possible connections for 16
consumption, power loss open communication by means of
type of voltage of the supply voltage DC SEND/RECEIVE blocks maximum
supply voltage 1 from backplane bus 5 V data volume
supply voltage external 24 V • as user data per ISO connection for 8 Kibyte
supply voltage external 24 V open communication by means of
at DC rated value SEND/RECEIVE blocks maximum
relative positive tolerance 20 % • as user data per 8 Kibyte
at DC at 24 V ISO on TCP connection for open
communication by means of
relative negative tolerance 15 % SEND/RECEIVE blocks maximum
at DC at 24 V
• as user data per TCP connection for 8 Kibyte
consumed current open communication by means of
• from backplane bus at DC 0.14 A SEND/RECEIVE blocks maximum
at 5 V typical • as user data per UDP connection for 2 Kibyte
• from external supply voltage 0.48 A open IE communication by means of
at DC at 24 V typical SEND/RECEIVE blocks maximum
• from external supply voltage 0.62 A number of Multicast stations 16
at DC at 24 V maximum
power loss [W] 14.7 W
■ Technical specifications
Article number 6GK7343-1GX31-0XE0 Article number 6GK7343-1GX31-0XE0
product type designation CP 343-1 Advanced product type designation CP 343-1 Advanced
performance data performance data
S7 communication PROFINET communication
number of possible connections for as PN IO device
S7 communication product function PROFINET IO device Yes
• maximum 16 data volume
performance data • as user data for input variables as 1 024 byte
multi-protocol mode PROFINET IO device maximum
number of active connections 48 • as user data for output variables as 1 024 byte
with multi-protocol mode PROFINET IO device maximum
5
performance data IT functions • as user data for input variables 240 byte
number of possible connections for each sub-module as
PROFINET IO device
• as client by means of FTP maximum 10
• as user data for output variables 240 byte
• as server by means of FTP maximum 2 for each sub-module as
number of possible connections PROFINET IO device
• as server by means of 4 • as user data for the consistency area 240 byte
HTTP maximum for each sub-module
• as email client maximum 1 number of submodules 32
per PROFINET IO-Device
data volume as user data for email 8 Kibyte
maximum performance data PROFINET CBA
storage capacity of the user memory number of remote connection 64
partners with PROFINET CBA
• as flash memory file system 28 Mibyte
number of connections 1 000
• as RAM 30 Mibyte with PROFINET CBA total
number of possible write cycles 100 000 data volume
of the flash memory cells
• as user data for digital inputs with 8 Kibyte
performance data PROFINET CBA maximum
PROFINET communication
as PN IO controller • as user data for digital outputs with 8 Kibyte
PROFINET CBA maximum
product function Yes
PROFINET IO controller • as user data for arrays and data 8 Kibyte
types in the case of acyclic
number of PN IO devices 128 transmission with PROFINET CBA
on PROFINET IO controller maximum
operable total
• as user data for arrays and data 250 byte
number of PN IO IRT devices on 128 types with PROFINET CBA
PROFINET IO controller operable with cyclical transfer maximum
number of external PN IO lines 1 • as user data for arrays and data 2 400 byte
with PROFINET per rack types with PROFINET CBA
data volume in the case of local interconnection
maximum
• as user data for input variables as 4 Kibyte
PROFINET IO controller maximum performance data
PROFINET CBA
• as user data for output variables as 4 Kibyte
remote interconnection
PROFINET IO controller maximum
with acyclic transfer
• as user data for input variables 1 433 byte
update time of the remote 100 ms
per PN IO device as
interconnections in the case of acyclic
PROFINET IO controller maximum
transmission with PROFINET CBA
• as user data for output variables 1 433 byte
number of remote connections to 128
per PN IO device as
input variables in the case of acyclic
PROFINET IO controller maximum
transmission with PROFINET CBA
• as user data for input variables per 240 byte maximum
PN IO device for each sub-module
number of remote connections to 128
as PROFINET IO controller
output variables in the case of acyclic
maximum
transmission with PROFINET CBA
• as user data for output variables per 240 byte maximum
PN IO device for each sub-module
data volume
as PROFINET IO controller
maximum • as user data for remote 8 Kibyte
interconnections with input variables
in the case of acyclic transmission
with PROFINET CBA
• as user data for remote 8 Kibyte
interconnections with output
variables in the case of acyclic
transmission with PROFINET CBA
■ Technical specifications
Article number 6GK7343-1GX31-0XE0 Article number 6GK7343-1GX31-0XE0
product type designation CP 343-1 Advanced product type designation CP 343-1 Advanced
performance data product functions management,
PROFINET CBA configuration, engineering
remote interconnection product function MIB support Yes
with cyclic transfer
protocol is supported
update time of the remote 8 ms
interconnections with PROFINET CBA • SNMP v1 Yes
with cyclical transfer • SNMP v3 Yes
number of remote connections to 200 • DCP Yes
input variables with PROFINET CBA
with cyclical transfer maximum • LLDP Yes
configuration software
5 number of remote connections to
output variables with PROFINET CBA
with cyclical transfer maximum
200
• required STEP7 V5.5 SP2 HF1 or higher /
STEP 7 Professional V12 (TIA Portal)
data volume or higher
• as user data for remote 2 000 byte • for PROFINET CBA required SIMATIC iMap V3.0 SP4 and higher
interconnections with input variables identification & maintenance function
with PROFINET CBA with cyclical
• I&M0 - device-specific information Yes
transfer maximum
• I&M1 – higher level designation/ Yes
• as user data for remote 2 000 byte
location designation
interconnections with output
variables with PROFINET CBA product functions diagnostics
with cyclical transfer maximum product function Yes
performance data PROFINET CBA web-based diagnostics
HMI variables via PROFINET acyclic product functions switch
number of connectable HMI stations 3 product feature switch Yes
for HMI variables in the case of
acyclic transmission with product function
PROFINET CBA • switch-managed No
update time of the HMI variables in 500 ms • with IRT PROFINET IO switch Yes
the case of acyclic transmission with
PROFINET CBA • configuration with STEP 7 Yes
5
(Type A)
4-core, shielded TP installation 6XV1840-2AH10
cable for connection to
IE FC outlet RJ45/ IE FC RJ45 plug;
PROFINET-compliant;
with UL approval;
sold by the meter;
max. delivery unit 1 000 m,
minimum order quantity 20 m
• Unmanaged switch for connecting a SIMATIC S7-300 with IE FC RJ45 plug 180 2 x 2
integral PROFINET interface or an Industrial Ethernet CP or
SIMATIC ET 200M to an Industrial Ethernet in an electrical line, RJ45 plug connector for
Industrial Ethernet with a rugged
tree or star structure metal housing and integrated
• As many as three additional nodes can be connected insulation displacement contacts
for connecting Industrial Ethernet
• As an unmanaged switch, the CSM 377 is used for integrating FC installation cables;
small machines into existing automation networks or for the 180° cable outlet; for network
stand-alone operation of the machines components and CPs/CPUs
with Industrial Ethernet interface
• Simple, space-saving attachment to SIMATIC S7-300 DIN rail • 1 pack = 1 unit 6GK1901-1BB10-2AA0
due to design as single-width module in SIMATIC S7-300 • 1 pack = 10 units 6GK1901-1BB10-2AB0
format • 1 pack = 50 units 6GK1901-1BB10-2AE0
• Low-cost solution for implementing small, local Ethernet IE FC Stripping Tool 6GK1901-1GA00
networks
Pre-adjusted stripping tool
• Rugged, industry-standard node connections with for fast stripping of
PROFINET-compliant RJ45 plug connectors that latch onto Industrial Ethernet FC cables
the enclosure to offer additional strain and bending relief
■ Technical specifications
Article number 6GK7377-1AA00-0AA0 Article number 6GK7377-1AA00-0AA0
product type designation SCALANCE CSM 377 product type designation SCALANCE CSM 377
transfer rate supply voltage, current
transfer rate 10 Mbit/s, 100 Mbit/s consumption, power loss
interfaces for communication type of voltage 1 DC
integrated of the supply voltage
number of electrical connections • supply voltage 1 rated value 24 V
• for network components or 4 • power loss [W] 1 rated value 1.6 W
terminal equipment • supply voltage 1 rated value 19.2 ... 28.8 V
number of 100 Mbit/s SC ports • consumed current 1 maximum 0.07 A
• for multimode 0 • type of electrical connection 1 2-pole terminal block
number of 1000 Mbit/s LC ports for power supply
• for multimode 0 • product component 1 fusing Yes
at power supply input
• for single mode (LD) 0
interfaces other
number of electrical connections
• for power supply 1
type of electrical connection
• for power supply 2-pole terminal block
■ Technical specifications
Article number 6GK7377-1AA00-0AA0 Article number 6GK7377-1AA00-0AA0
product type designation SCALANCE CSM 377 product type designation SCALANCE CSM 377
ambient conditions standards, specifications, approvals
ambient temperature standard
• during operation 0 ... 60 °C • for FM FM3611: Class 1, Divison 2,
• during storage -40 ... +70 °C Group A, B, C, D / T.., CL.1, Zone 2,
GP. IIC, T.. Ta
• during transport -40 ... +70 °C
• for safety from CSA and UL UL 508, CSA C22.2 No. 142
relative humidity
• for emitted interference EN 61000-6-4:2001
• at 25 °C without condensation 95 %
during operation maximum • for interference immunity EN 61000-6-2:2001
protection class IP IP20 MTBF 144 y
■ Overview
• SINAUT communications module TIM for SIMATIC S7-300
for use in a wide area network (WAN)
• IP communication via secure VPN (virtual private network)
using the Internet
• Wireless communication via mobile wireless routers or
wireless devices
• Wired communication via Ethernet, DSL, dialup modems or
dedicated line modem
• Complete migration of existing wireless, dedicated line and
dial-up technology to IP-based network
• Frame buffer for seamless recording of data
• Simple configuration and operation without specialist 5
IT knowledge
■ Technical specifications
Article number 6NH7800-3BA00 Article number 6NH7800-3BA00
product type designation TIM 3V-IE product type designation TIM 3V-IE
transfer rate ambient conditions
transfer rate ambient temperature
• for Industrial Ethernet 10 ... 100 Mbit/s • during operation 0 ... 60 °C
• acc. to RS 232 50 ... 38 400 bit/s • during storage -40 ... +70 °C
interfaces • during transport -40 ... +70 °C
number of interfaces 1 relative humidity
acc. to Industrial Ethernet • at 25 °C without condensation 95 %
number of electrical connections during operation maximum
• for external data transmission 1 protection class IP IP20
5 acc. to RS 232
• for power supply 1
design, dimensions and weights
module format Compact module S7-300
type of electrical connection single width
• of Industrial Ethernet interface RJ45 port width 40 mm
type of electrical connection height 125 mm
• at interface 1 for external 9 pin Sub-D-connector (RS232) depth 120 mm
data transmission net weight 0.25 kg
• for power supply 2-pole plugable terminal block product features, product functions,
design of the removable storage product components general
• C-PLUG No number of units
supply voltage, current • per CPU maximum 1
consumption, power loss • note Number of TIM per S7-300
type of voltage of the supply voltage DC wire length
supply voltage 24 V • with RS 232 interface maximum 6m
supply voltage 20.4 ... 28.8 V performance data
supply voltage external 24 V S7 communication
at DC rated value number of possible connections
supply voltage external 20.4 ... 28.8 V for S7 communication
at DC rated value • maximum 8
relative symmetrical tolerance at DC • with PG connections maximum 2
• at 5 V 5% • with OP connections maximum 8
relative positive tolerance 5% service
at DC at 24 V
• SINAUT ST7 via S7 communication Yes
relative negative tolerance 5%
at DC at 24 V • PG/OP communication Yes
consumed current performance data
multi-protocol mode
• from backplane bus 0.2 A
at DC at 24 V maximum number of active connections 12
with multi-protocol mode
• from external supply voltage 0.2 A
at DC at 24 V maximum
power loss [W] 5.8 W
product extension optional backup No
battery
■ Technical specifications
Article number 6NH7800-3BA00 Article number 6NH7800-3BA00
product type designation TIM 3V-IE product type designation TIM 3V-IE
performance data telecontrol product functions management,
suitability for use configuration, engineering
• node station No configuration software
• substation Yes • required SINAUT ST7 ES
• TIM control center No • for CPU configuring required Yes
SINAUT TD7 block library for CPU
• note RS232 and Industrial Ethernet
can not be operated in parallel • for PG configuring required Yes
SINAUT ST7 configuration software
protocol is supported for PG
• DNP3 No
5
storage location of TIM configuration on the TIM
• SINAUT ST1 protocol Yes data
• SINAUT ST7 protocol Yes product functions security
product function data buffering Yes; 16,000 data messages operating mode Yes; VPN operation as MSC client
if connection is aborted Virtual Private Network (VPN) with MSC protocol and password
protection only possible in
storage capacity conjunction with GPRS modem with
• of S7 CPU work memory 20 Kibyte MSC capability
for TD7onCPU mode data blocks type of authentication with Yes
on CPU required Virtual Private Network PSK
• of S7 CPU work memory 0 Kibyte product function
for TD7onTIM mode data blocks
on TIM required • password protection for VPN Yes
• note TD7onCPU: at least 20 KB, • MSC client via GPRS modem Yes
actual requirement determined by with MSC capability
data volume and functional scope protocol
TD7onTIM: 0 bytes in most favorable
case • is supported MSC protocol No
product feature buffered message No key length for MSC with 128 bit
frame memory Virtual Private Network
transmission format number of possible connections
• for SINAUT ST1 protocol Yes • as MSC client with VPN connection 1
with polling 11 bit • as MSC server with VPN connection 0
• for SINAUT ST1 protocol Yes standards, specifications, approvals
with spontaneous 10-bit or 11-bit hazardous environments
• for SINAUT ST7 protocol Yes certificate of suitability CCC Yes
with multi-master polling 10-bit for hazardous zone according to
• for SINAUT ST7 protocol with polling Yes GB standard
or spontaneous 10-bit or 11-bit
operating mode for scanning of
data transmission
• with dedicated line/radio link Polling, polling with time slot proce-
with SINAUT ST1 protocol dure
• with dedicated line/radio link Polling, polling with time slot proce-
with SINAUT ST7 protocol dure, multi-master polling with time
slot procedure
• with dial-up network spontaneous
with SINAUT ST1 protocol
• with dial-up network spontaneous
with SINAUT ST7 protocol
hamming distance
• for SINAUT ST1 protocol 4
• for SINAUT ST7 protocol 4
■ Overview
• SINAUT communications module TIM for SIMATIC S7-300
for use in wide area network (WAN) as station, node station,
and control center
• IP communication via secure VPN (virtual private network)
using the Internet
• Wireless communication via mobile wireless routers or
wireless devices
• Wired communication via Ethernet, DSL, dialup modems or
dedicated line modem
• Complete migration of existing wireless, dedicated line and
dial-up technology to IP-based network
5 • Message frame memory for seamless recording of data and
support of redundant communication paths
• Simple configuration and operation without specialist
IT knowledge
■ Technical specifications
Article number 6NH7800-3CA00 Article number 6NH7800-3CA00
product type designation TIM 3V-IE Advanced product type designation TIM 3V-IE Advanced
transfer rate ambient conditions
transfer rate ambient temperature
• for Industrial Ethernet 10 ... 100 Mbit/s • during operation 0 ... 60 °C
• acc. to RS 232 50 ... 38 400 bit/s • during storage -40 ... +70 °C
interfaces • during transport -40 ... +70 °C
number of interfaces 1 relative humidity
acc. to Industrial Ethernet • at 25 °C without condensation 95 %
number of electrical connections during operation maximum
• for external data transmission 1 protection class IP IP20
acc. to RS 232
• for power supply 1
design, dimensions and weights 5
module format Compact module S7-300
type of electrical connection single width
• of Industrial Ethernet interface RJ45 port width 40 mm
type of electrical connection height 125 mm
• at interface 1 for external 9 pin Sub-D-connector (RS232) depth 120 mm
data transmission net weight 0.25 kg
• for power supply 2-pole plugable terminal block product features, product functions,
design of the removable storage product components general
• C-PLUG No number of units
supply voltage, current • note Number of TIMs per S7-300:
consumption, power loss multiple, number depends
type of voltage of the supply voltage DC on the connection resources of the
S7-300 CPU
supply voltage 24 V
wire length
supply voltage 20.4 ... 28.8 V
• with RS 232 interface maximum 6m
supply voltage external 24 V
at DC rated value performance data
S7 communication
supply voltage external 20.4 ... 28.8 V
at DC rated value number of possible connections
for S7 communication
relative symmetrical tolerance at DC
• maximum 24
• at 5 V 5%
• with PG connections maximum 4
relative positive tolerance 5%
at DC at 24 V • with OP connections maximum 20
relative negative tolerance 5% service
at DC at 24 V • SINAUT ST7 via S7 communication Yes
consumed current • PG/OP communication Yes
• from backplane bus at DC 0.2 A performance data
at 24 V maximum multi-protocol mode
• from external supply voltage at DC 0.2 A number of active connections 24
at 24 V maximum with multi-protocol mode
power loss [W] 5.8 W
product extension optional backup No
battery
■ Technical specifications
Article number 6NH7800-3CA00 Article number 6NH7800-3CA00
product type designation TIM 3V-IE Advanced product type designation TIM 3V-IE Advanced
performance data telecontrol product functions management,
suitability for use configuration, engineering
• node station Yes configuration software
• substation Yes • required SINAUT ST7 ES
• TIM control center Yes • for CPU configuring required Yes
SINAUT TD7 block library for CPU
• note RS232 and Industrial Ethernet
can be operated in parallel • for PG configuring required Yes
SINAUT ST7 configuration software
protocol is supported for PG
• DNP3 No
5
storage location of TIM configuration on the TIM
• SINAUT ST1 protocol Yes data
• SINAUT ST7 protocol Yes product functions security
product function data buffering Yes; 32,000 data messages operating mode Yes
if connection is aborted Virtual Private Network (VPN)
storage capacity type of authentication with Yes
Virtual Private Network PSK
• of S7 CPU work memory 20 Kibyte
for TD7onCPU mode data blocks product function
on CPU required • password protection for VPN Yes
• of S7 CPU work memory 0 Kibyte • MSC client via GPRS modem Yes
for TD7onTIM mode data blocks with MSC capability
on TIM required
protocol
• note TD7onCPU: at least 20 KB,
actual requirement determined by • is supported MSC protocol Yes
data volume and functional scope • with Virtual Private Network MSC TCP/IP
TD7onTIM: 0 bytes in most favorable is supported
case key length for MSC with 128 bit
product feature buffered message No Virtual Private Network
frame memory number of possible connections
transmission format • as MSC client with VPN connection 1
• for SINAUT ST1 protocol Yes • as MSC server with VPN connection 0
with polling 11 bit
standards, specifications, approvals
• for SINAUT ST1 protocol Yes hazardous environments
with spontaneous 10-bit or 11-bit
certificate of suitability CCC Yes
• for SINAUT ST7 protocol Yes for hazardous zone according to
with multi-master polling 10-bit GB standard
• for SINAUT ST7 protocol with polling Yes
or spontaneous 10-bit or 11-bit
operating mode for scanning of
data transmission
• with dedicated line/radio link Polling, polling with time slot
with SINAUT ST1 protocol procedure
• with dedicated line/radio link Polling, polling with time slot
with SINAUT ST7 protocol procedure, multi-master polling
with time slot procedure
• with dial-up network spontaneous
with SINAUT ST1 protocol
• with dial-up network spontaneous
with SINAUT ST7 protocol
hamming distance
• for SINAUT ST1 protocol 4
• for SINAUT ST7 protocol 4
■ Overview
• SINAUT communications module TIM with four interfaces for
SIMATIC S7-300 or as self-contained unit for the S7-400 for
use in the wide area network (WAN)
• For universal use in a SINAUT station, node station and control
center
• Internet communication via integrated MSC-VPN tunnel with
direct connection to DSL router or operation via IPsec VPN
with additional SIMATIC NET components
• Wireless communication via mobile wireless routers or
wireless devices
• Wired communication via Ethernet, DSL, dialup modems or
dedicated line modem
• Complete migration of existing wireless, dedicated line and
5
dial-up technology to IP-based network
• Message frame memory for seamless recording of data and
support of redundant communication paths
• Simple configuration and operation without specialist
IT knowledge
■ Technical specifications
Article number 6NH7800-4BA00 Article number 6NH7800-4BA00
product type designation TIM 4R-IE product type designation TIM 4R-IE
transfer rate ambient conditions
transfer rate ambient temperature
• for Industrial Ethernet 10 ... 100 Mbit/s • during operation 0 ... 60 °C
• acc. to RS 232 50 ... 38 400 bit/s • during storage -40 ... +70 °C
interfaces • during transport -40 ... +70 °C
number of interfaces 2 relative humidity
acc. to Industrial Ethernet • at 25 °C without condensation 95 %
number of electrical connections during operation maximum
• for external data transmission 2 protection class IP IP20
5 acc. to RS 232
• for power supply 1
design, dimensions and weights
module format Compact module S7-300
type of electrical connection double width
• of Industrial Ethernet interface RJ45 port width 80 mm
type of electrical connection height 125 mm
• at interface 1 for external 9 pin Sub-D-connector, depth 120 mm
data transmission RS232 switchable to RS485 net weight 0.4 kg
• at interface 2 for external 9-pole D-sub connector, product features, product functions,
data transmission RS232 can be switched to RS485 product components general
• for power supply 2-pole plugable terminal block number of units
design of the removable storage • note Number of TIM 4R-IE
• C-PLUG Yes per S7-300/S7-400: multiple,
supply voltage, current number depends on the connection
consumption, power loss resources of the CPU
type of voltage of the supply voltage DC wire length
supply voltage 24 V • with RS 232 interface maximum 6m
supply voltage 20.4 ... 28.8 V • with RS 485 interface maximum 30 m
supply voltage external 24 V performance data
at DC rated value S7 communication
supply voltage external 20.4 ... 28.8 V number of possible connections for
at DC rated value S7 communication
consumed current • maximum 64
• from backplane bus 0.2 A • with PG connections maximum 2
at DC at 24 V maximum • with OP connections maximum 62
• from external supply voltage 0.17 A service
at DC at 24 V maximum • SINAUT ST7 via S7 communication Yes
power loss [W] 4.6 W • PG/OP communication Yes
product extension optional backup Yes performance data
battery multi-protocol mode
type of battery Lithium AA / 3.6 V / 2.3 Ah number of active connections 128
backup current with multi-protocol mode
• typical 100 µA
• maximum 160 µA
■ Technical specifications
Article number 6NH7800-4BA00 Article number 6NH7800-4BA00
product type designation TIM 4R-IE product type designation TIM 4R-IE
performance data telecontrol product functions management,
suitability for use configuration, engineering
• node station Yes configuration software
• substation Yes • required SINAUT ST7 ES
• TIM control center Yes • for CPU configuring required Yes
SINAUT TD7 block library for CPU
protocol is supported
• for PG configuring required Yes
• DNP3 No SINAUT ST7 configuration software
• SINAUT ST1 protocol Yes for PG
5
• SINAUT ST7 protocol Yes storage location of TIM configuration on internal TIM flash memory, or on
data TIM in optional C-PLUG, or on MMC
product function data buffering Yes; 56,000 data messages of the S7-300 CPU if TIM installed in
if connection is aborted S7-300 controller
storage capacity product functions security
• of S7 CPU work memory 20 Kibyte operating mode Yes
for TD7onCPU mode data blocks Virtual Private Network (VPN)
on CPU required
type of authentication with Yes
• of S7 CPU work memory 0 Kibyte Virtual Private Network PSK
for TD7onTIM mode data blocks
on TIM required product function
• note TD7onCPU: at least 20 KB, • password protection for VPN Yes
actual requirement determined by • MSC client via GPRS modem Yes
data volume and functional scope with MSC capability
TD7onTIM: 0 bytes in most favorable
case protocol
product feature buffered message Yes • is supported MSC protocol Yes
frame memory • with Virtual Private Network MSC TCP/IP
transmission format is supported
• for SINAUT ST1 protocol Yes key length for MSC with 128 bit
with polling 11 bit Virtual Private Network
• for SINAUT ST1 protocol Yes number of possible connections
with spontaneous 10-bit or 11-bit • as MSC client with VPN connection 1
• for SINAUT ST7 protocol Yes • as MSC server with VPN connection 128
with multi-master polling 10-bit product functions time
• for SINAUT ST7 protocol with polling Yes product component hardware real Yes
or spontaneous 10-bit or 11-bit time clock
operating mode for scanning of product feature hardware real time Yes
data transmission clock w. battery backup
• with dedicated line/radio link Polling, polling with time slot accuracy of the hardware real time 4s
with SINAUT ST1 protocol procedure clock per day maximum
• with dedicated line/radio link Polling, polling with time slot time synchronization
with SINAUT ST7 protocol procedure, multi-master polling
with time slot procedure • from NTP-server Yes
• with dial-up network spontaneous standards, specifications, approvals
with SINAUT ST1 protocol hazardous environments
• with dial-up network spontaneous certificate of suitability CCC Yes
with SINAUT ST7 protocol for hazardous zone according to
GB standard
hamming distance
• for SINAUT ST1 protocol 4
• for SINAUT ST7 protocol 4
■ Overview
In a station for the S7-CPU, the communications module
TIM 3V-IE DNP3 (TeleControl Interface Module) handles the data
exchange with the assigned master system SIMATIC PCS 7
TeleControl V8.0 using the open DNP3 protocol. The module
additionally supports master and node functionality.
• With the S7-300 housing, the module can be fully integrated
into the S7-300 system
• The module has an RS232 interface for the connection of an
external modem for data transmission via a conventional WAN
or the connection of a Modbus RTU slave to an S7-300 system
• The RJ45 port is used for data transmission via IP-based
5 networks
■ Technical specifications
Article number 6NH7803-3BA00-0AA0 Article number 6NH7803-3BA00-0AA0
product type designation TIM 3V-IE DNP3 product type designation TIM 3V-IE DNP3
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-300
• for Industrial Ethernet 10 ... 100 Mbit/s single width
• acc. to RS 232 9 600 ... 38 400 bit/s width 40 mm
interfaces height 125 mm
number of interfaces 1 depth 120 mm
acc. to Industrial Ethernet net weight 0.25 kg
number of electrical connections product features, product functions,
• for external data transmission 1 product components general
acc. to RS 232
• for power supply 1
number of units
• note Number of TIMs per S7-300: 1
5
type of electrical connection wire length
• of Industrial Ethernet interface RJ45 port • with RS 232 interface maximum 6m
type of electrical connection performance data
• at interface 1 for external data 9 pin Sub-D-connector (RS232) S7 communication
transmission number of possible connections
• for power supply 2-pole plugable terminal block for S7 communication
design of the removable storage • maximum 3; only via LAN
• C-PLUG No • with PG connections maximum 2
supply voltage, current • with OP connections maximum 1
consumption, power loss service
type of voltage of the supply voltage DC • PG/OP communication Yes
supply voltage 24 V performance data telecontrol
supply voltage 20.4 ... 28.8 V suitability for use
supply voltage external 24 V • node station Yes
at DC rated value • substation Yes
supply voltage external 20.4 ... 28.8 V • TIM control center Yes
at DC rated value
protocol is supported
consumed current
• DNP3 Yes
• from backplane bus 0.2 A
at DC at 24 V maximum • SINAUT ST1 protocol No
• from external supply voltage 0.2 A • SINAUT ST7 protocol No
at DC at 24 V maximum • Modbus RTU Yes
power loss [W] 5.8 W product function data buffering Yes; 64,000 data points with one
product extension optional backup No if connection is aborted master
battery number of DNP3 masters
ambient conditions • for Ethernet maximum 8
ambient temperature • with RS 232 interface maximum 1
• during operation 0 ... 60 °C number of Modbus RTU slaves 1
• during storage -40 ... +70 °C maximum
• during transport -40 ... +70 °C product functions management,
configuration, engineering
relative humidity
configuration software
• at 25 °C without condensation 95 %
during operation maximum • required SINAUT ST7 ES
protection class IP IP20 storage location of TIM configuration on the CPU or TIM
data
standards, specifications, approvals
hazardous environments
certificate of suitability CCC Yes
for hazardous zone according to
GB standard
■ Overview
In a station for the S7-CPU, the communication module
TIM 4R-IE DNP3 (TeleControl Interface Module) handles the data
exchange with the assigned SIMATIC PCS7 TeleControl V8.0
master system using the open DNP3 protocol. In addition, the
V3.0 module now also supports master and node functionality.
• With the double-width S7-300 housing, the module can be
fully integrated into the S7-300 system
• Can be connected as a stand-alone module to a
SIMATIC S7-400 and SIMATIC S7-400 H System
• Two RS 232/RS 485 interfaces support connection of an
external modem for data transmission via a conventional WAN
■ Technical specifications
Article number 6NH7803-4BA00-0AA0 Article number 6NH7803-4BA00-0AA0
product type designation TIM 4R-IE DNP3 product type designation TIM 4R-IE DNP3
transfer rate design, dimensions and weights
transfer rate module format Compact module S7-300
• for Industrial Ethernet 10 ... 100 Mbit/s double width
• acc. to RS 232 9 600 ... 115 200 bit/s width 80 mm
interfaces height 125 mm
number of interfaces 2 depth 120 mm
acc. to Industrial Ethernet net weight 0.4 kg
number of electrical connections product features, product functions,
• for external data transmission 2 product components general
acc. to RS 232
• for power supply 1
number of units
• note Number of TIMs per S7-300 / S7-400:
5
type of electrical connection 1
• of Industrial Ethernet interface RJ45 port wire length
type of electrical connection • with RS 232 interface maximum 6m
• at interface 1 for external data 9 pin Sub-D-connector, • with RS 485 interface maximum 30 m
transmission RS232 switchable to RS485 performance data
• at interface 2 for external data 9-pole D-sub connector, S7 communication
transmission RS232 can be switched to RS485 number of possible connections
• for power supply 2-pole plugable terminal block for S7 communication
design of the removable storage • maximum 5; only via LAN
• C-PLUG Yes • with PG connections maximum 2
supply voltage, current • with OP connections maximum 1
consumption, power loss service
type of voltage of the supply voltage DC • PG/OP communication Yes
supply voltage 24 V performance data telecontrol
supply voltage 20.4 ... 28.8 V suitability for use
supply voltage external 24 V • node station Yes
at DC rated value • substation Yes
supply voltage external 20.4 ... 28.8 V • TIM control center Yes
at DC rated value
protocol is supported
consumed current
• DNP3 Yes
• from backplane bus 0.2 A
at DC at 24 V maximum • SINAUT ST1 protocol No
• from external supply voltage 0.17 A • SINAUT ST7 protocol No
at DC at 24 V maximum • Modbus RTU Yes
power loss [W] 4.6 W product function data buffering Yes; 200,000 data points with one
product extension optional backup Yes if connection is aborted master
battery number of DNP3 masters
type of battery Lithium AA / 3.6 V / 2.3 Ah • for Ethernet maximum 8
backup current • with RS 232 interface maximum 1
• typical 100 µA number of Modbus RTU slaves 1
• maximum 160 µA maximum
ambient conditions product functions management,
configuration, engineering
ambient temperature
configuration software
• during operation 0 ... 60 °C
• required SINAUT ST7 ES
• during storage -40 ... +70 °C
storage location of TIM configuration on the CPU or TIM
• during transport -40 ... +70 °C data
relative humidity product functions time
• at 25 °C without condensation 95 % product component hardware real Yes
during operation maximum time clock
protection class IP IP20 product feature hardware real time Yes
clock w. battery backup
accuracy of the hardware real time 4s
clock per day maximum
time synchronization
• from NTP-server Yes
standards, specifications, approvals
hazardous environments
certificate of suitability CCC Yes
for hazardous zone according to
GB standard
■ Technical specifications
Article number 6GT2002-0GA10 Article number 6GT2002-0GA10
product type designation ASM 475 communication module product type designation ASM 475 communication module
product features, product functions, standards, specifications, approvals
product components general certificate of suitability CE, FCC, UL/CSA
display version 4 LEDs per reader connection, accessories
2 LEDs for device status
accessories Front connector with screw-type or
product function addressable Yes spring-loaded terminals
transponder file handler
protocol is supported
• S7 communication Yes
product functions management,
5
configuration, engineering
type of parameterization Object manager, GSD
type of programming FB 45, FB 55, FC 56
(FC 45/55 with limited functionality)
type of computer-switched acyclic communication
communication
■ Technical specifications
Article number 6AG1340-1AH02-2AE0 6AG1340-1CH02-2AE0
Based on 6ES7340-1AH02-0AE0 6ES7340-1CH02-0AE0
SIPLUS S7-300 CP340 RS232 SIPLUS S7-300 CP340 RS422/485
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 60 °C; = Tmax
Ambient temperature
during storage/transportation
• min. -40 °C -40 °C
• max. 70 °C 70 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
■ Technical specifications
Article number 6AG1340-1AH02-2AE0 6AG1340-1CH02-2AE0
Based on 6ES7340-1AH02-0AE0 6ES7340-1CH02-0AE0
SIPLUS S7-300 CP340 RS232 SIPLUS S7-300 CP340 RS422/485
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
5
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
5 Task:
Communication via
Modbus protocol with RTU format,
SIMATIC S7 as master
Requirement:
CP 341 or CP 441-2;
STEP 7 V4.02 and higher
Delivery package:
• For fast, high-performance serial data exchange Driver program/documentation,
English, German, French
via point-to-point coupling
Single license 6ES7870-1AA01-0YA0
• Two versions with different physical transmission
characteristics: Single license, without software and 6ES7870-1AA01-0YA1
- RS 232C (V.24), documentation
- RS 422/RS 485 (X.27) Modbus Slave V3.1
• Implemented protocols: ASCII, 3964 (R), RK 512, customized Task:
protocols (can be reloaded) Communication via
Modbus protocol with RTU format,
• Simple parameter assignment using tool integrated in STEP 7 SIMATIC S7 as slave
Requirement:
Note: CP 341 or CP 441-2;
STEP 7 V4.02 and higher
SIPLUS extreme products are based on SIMATIC standard Delivery package:
products. The contents listed here were taken from the Driver program/documentation,
respective standard products. SIPLUS extreme specific English, German, French
information was added. Single license 6ES7870-1AB01-0YA0
Single license, without software and 6ES7870-1AB01-0YA1
documentation
■ Technical specifications
Article number 6AG1341-1AH02-7AE0 6AG1341-1CH02-7AE0
Based on 6ES7341-1AH02-0AE0 6ES7341-1CH02-0AE0
SIPLUS S7-300 CP341 RS232C SIPLUS S7-300 CP341 RS422/485
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient temperature
during storage/transportation
• min. -40 °C -40 °C
• max. 70 °C 70 °C
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at Tmin ... Tmax at
barometric pressure-altitude 1 140 hPa ... 795 hPa 1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at Tmin ... (Tmax - 10 K) at
795 hPa ... 658 hPa 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at Tmin ... (Tmax -20 K) at
658 hPa ... 540 hPa 658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost
tested in accordance (no commissioning under condensation conditions) (no commissioning under condensation conditions)
with IEC 60068-2-38, max.
■ Technical specifications
Article number 6AG1341-1AH02-7AE0 6AG1341-1CH02-7AE0
Based on 6ES7341-1AH02-0AE0 6ES7341-1CH02-0AE0
SIPLUS S7-300 CP341 RS232C SIPLUS S7-300 CP341 RS422/485
Resistance
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold and fungal spores (excluding fauna);
5
according to EN 60721-3-6 Class 6B3 on request Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
■ Technical specifications
Article number 6AG1343-1CX10-2XE0 Article number 6AG1343-1CX10-2XE0
Based on 6GK7343-1CX10-0XE0 Based on 6GK7343-1CX10-0XE0
product type designation SIPLUS NET CP343-1 LEAN product type designation SIPLUS NET CP343-1 LEAN
ambient conditions resistance to chemically active
ambient temperature substances
• for vertical installation -25 ... +40 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
during operation incl. salt spray in accordance
with EN 60068-2-52 (Severity 3).
• for horizontally arranged busbars -25 ... +60 °C The supplied plug covers must
during operation remain in place on the unused
• during storage -40 ... +70 °C interfaces during operation.
• during transport -40 ... +70 °C • conformity acc. to EN 60721-3-6 Yes
■ Overview
• Communications services:
- Open communication (ISO, TCP/IP, and UDP)
- PROFINET IO controller or PROFINET IO device
- PG/OP communication: Cross-network by means of
S7 routing
- S7 communication (client, server, multiplexing)
• Media redundancy (MRP);
within an Ethernet network with ring topology, the CP supports
the media redundancy procedure MRP (V2.2 or higher).
• Multicast for UDP
• IP address assignment via DHCP, simple PC tool or
via the user program (e.g. HMI)
• Access protection via configurable access list 5
• Remote programming and commissioning
via Industrial Ethernet
• Configuration with STEP 7
• Automatic setting of CPU clock setting over Ethernet with NTP
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5
or SIMATIC procedure
UDP • Web diagnostics
G_IK10_XX_10147
■ Technical specifications
Article number 6AG1343-1EX30-7XE0 Article number 6AG1343-1EX30-7XE0
Based on 6GK7343-1EX30-0XE0 Based on 6GK7343-1EX30-0XE0
product type designation SIPLUS NET CP 343-1 product type designation SIPLUS NET CP 343-1
ambient conditions resistance to chemically active
ambient temperature substances
• during operation -25 ... +70 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
incl. salt spray in accordance
• during storage -40 ... +70 °C with EN 60068-2-52 (Severity 3).
• during transport -40 ... +70 °C The supplied plug covers must
remain in place on the unused
installation altitude at height above 5 000 m interfaces during operation.
sea level maximum
• conformity acc. to EN 60721-3-6 Yes
ambient condition relating to Tmin ... Tmax at
ambient temperature - air pressure - 1 140 hPa ... 795 hPa resistance to mechanically active
installation altitude (-1 000 m ... +2 000 m) // substances
Tmin ... (Tmax - 10 K) at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
795 hPa ... 658 hPa The supplied plug covers must
(+2 000 m ... +3 500 m) // remain in place over the unused
Tmin ... (Tmax - 20 K) at interfaces during operation.
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
The supplied plug covers must
relative humidity remain in place over the unused
• with condensation acc. to 100 %; RH including condensation/ interfaces during operation.
IEC 60068-2-38 maximum frost (no commissioning when coating for equipped printed circuit Yes; Class 2 for high availability
condensation is present), board acc. to EN 61086
horizontal installation
type of coating protection against Yes; Protection of the type 1
chemical resistance to commercially Yes; incl. airborne diesel and oil pollution according to EN 60664-3
available cooling lubricants droplets
type of test of the coating acc. to Yes; Coating discoloration
resistance to biologically active MIL-I-46058C during service life possible
substances
product conformity of the coating Yes; Conformal coating, class A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal Qualification and Performance of
spores (excluding fauna), Electrical Insulating Compound for
Class 3B3 on request Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and IPC-CC-830A
dry rot spores (excluding fauna) protection class IP IP20
■ Overview
• Communications services via PROFINET interfaces:
- PROFINET IO controller and IO device with real-time
properties (RT and IRT)1)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or
via program block (e.g. for HMI)
- Configuration with STEP 7
• Media redundancy (MRP);
within an Ethernet network with ring topology, the CP supports
the media redundancy procedure MRP (V2.2 or higher).
• Access protection by means of configurable IP access list
• Module replacement without programming device;
all information is stored on the C-PLUG 5
(also file system for IT functions)
• Extensive diagnostic functions for all modules in the rack
• IT communication
- Web function
- E-mail function
ISO TCP/ PN MRP IT IP-R PG/OP S7/S5 - FTP
UDP • Integration into network management systems through the
G_IK10_XX_10145
■ Technical specifications
Article number 6AG1343-1GX31-4XE0 Article number 6AG1343-1GX31-4XE0
Based on 6GK7343-1GX31-0XE0 Based on 6GK7343-1GX31-0XE0
product type designation SIPLUS NET CP343-1 ADVANCED product type designation SIPLUS NET CP343-1 ADVANCED
ambient conditions resistance to chemically active
ambient temperature substances
• for vertical installation 0 ... 40 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
during operation incl. salt spray in accordance
with EN 60068-2-52 (Severity 3).
• for horizontally arranged busbars 0 ... 60 °C The supplied plug covers must
during operation remain in place on the unused
• during storage -40 ... +70 °C interfaces during operation.
• during transport -40 ... +70 °C • conformity acc. to EN 60721-3-6 Yes
installation altitude at height above
sea level maximum
5 000 m resistance to mechanically active
substances 5
ambient condition relating to Tmin ... Tmax at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
ambient temperature - air pressure - 1 140 hPa ... 795 hPa The supplied plug covers must
installation altitude (-1 000 m ... +2 000 m) // remain in place over the unused
Tmin ... (Tmax - 10 K) at interfaces during operation.
795 hPa ... 658 hPa • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
(+2 000 m ... +3 500 m) // The supplied plug covers must
Tmin ... (Tmax - 20 K) at remain in place over the unused
658 hPa ... 540 hPa interfaces during operation.
(+3 500 m ... +5 000 m)
coating for equipped printed circuit Yes; Class 2 for high availability
relative humidity board acc. to EN 61086
• with condensation acc. to 100 %; RH including condensation/ type of coating protection against Yes; Protection of the type 1
IEC 60068-2-38 maximum frost (no commissioning pollution according to EN 60664-3
when condensation is present),
horizontal installation type of test of the coating acc. to Yes; Coating discoloration during
MIL-I-46058C service life possible
chemical resistance to commercially Yes; incl. airborne diesel and oil
available cooling lubricants droplets product conformity of the coating Yes; Conformal coating, class A
Qualification and Performance of
resistance to biologically active Electrical Insulating Compound for
substances Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal IPC-CC-830A
spores (excluding fauna), protection class IP IP20
Class 3B3 on request
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and
dry rot spores (excluding fauna)
5 for connection to IE
FC outlet RJ45/IE FC RJ45 plug;
PROFINET-compliant;
with UL approval;
sold by the meter;
max. delivery unit 1000 m,
minimum order quantity 20 m
IE FC RJ45 plug 180
• SINAUT communication module SIPLUS TIM for RJ45 plug connector for
Industrial Ethernet with a rugged
SIMATIC S7-300 for use in a wide area network (WAN) metal housing and integrated
• IP communication via secure VPN (virtual private network) insulation displacement contacts for
using the Internet connecting Industrial Ethernet FC
installation cables;
• Wireless communication via GPRS router, GPRS modem, with 180° cable outlet;
or radio devices for network components and
CPs/CPUs with Industrial Ethernet
• Wired communication via Ethernet, DSL, dialup modems or interface
dedicated line modem • 1 pack = 1 unit, 6AG1901-1BB10-7AA0
• Complete migration of existing wireless, dedicated line and -40 ... +70 °C, exposure to media
dial-up technology to IP-based network IE FC stripping tool 6GK1901-1GA00
• Message frame memory for seamless recording of data Preadjusted stripping tool
for fast stripping of
• Simple configuration and operation without specialist Industrial Ethernet FC cables
IT knowledge
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were adopted from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1800-3BA00-7AA0 Article number 6AG1800-3BA00-7AA0
Based on 6NH7800-3BA00 Based on 6NH7800-3BA00
product type designation SIPLUS SINAUT ST7, TIM 3V-IE product type designation SIPLUS SINAUT ST7, TIM 3V-IE
ambient conditions resistance to chemically active
ambient temperature substances
• during operation -25 ... +70 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
incl. salt spray in accordance
• during storage -40 ... +70 °C with EN 60068-2-52 (Severity 3).
• during transport -40 ... +70 °C The supplied plug covers must
remain in place on the unused
installation altitude at height above 5 000 m interfaces during operation.
sea level maximum
• conformity acc. to EN 60721-3-6 Yes
ambient condition relating to Tmin ... Tmax at
ambient temperature - air pressure -
installation altitude
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
resistance to mechanically active
substances 5
Tmin ... (Tmax - 10 K) at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
795 hPa ... 658 hPa The supplied plug covers must
(+2 000 m ... +3 500 m) // remain in place over the unused
Tmin ... (Tmax - 20 K) at interfaces during operation.
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
The supplied plug covers must
relative humidity remain in place over the unused
• with condensation acc. to 100 %; RH including condensation/ interfaces during operation.
IEC 60068-2-38 maximum frost (no commissioning coating for equipped printed circuit Yes; Class 2 for high availability
when condensation is present), board acc. to EN 61086
horizontal installation
type of coating protection against Yes; Protection of the type 1
chemical resistance to commercially Yes; incl. airborne diesel and oil pollution according to EN 60664-3
available cooling lubricants droplets
type of test of the coating acc. to Yes; Coating discoloration during
resistance to biologically active MIL-I-46058C service life possible
substances
product conformity of the coating Yes; Conformal coating, class A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal Qualification and Performance of
spores (excluding fauna), Electrical Insulating Compound for
Class 3B3 on request Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and IPC-CC-830A
dry rot spores (excluding fauna) protection class IP IP20
■ Technical specifications
Article number 6AG1800-4BA00-7AA0 Article number 6AG1800-4BA00-7AA0
Based on 6NH7800-4BA00 Based on 6NH7800-4BA00
product type designation SIPLUS SINAUT ST7, TIM 4R-IE product type designation SIPLUS SINAUT ST7, TIM 4R-IE
ambient conditions resistance to chemically active
ambient temperature substances
• during operation -25 ... +70 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
incl. salt spray in accordance
• during storage -40 ... +70 °C with EN 60068-2-52 (Severity 3).
• during transport -40 ... +70 °C The supplied plug covers must
remain in place on the unused
installation altitude at height above 5 000 m interfaces during operation.
sea level maximum
• conformity acc. to EN 60721-3-6 Yes
ambient condition relating to Tmin ... Tmax at
ambient temperature - air pressure -
installation altitude
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
resistance to mechanically active
substances 5
Tmin ... (Tmax - 10 K) at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
795 hPa ... 658 hPa The supplied plug covers must
(+2 000 m ... +3 500 m) // remain in place over the unused
Tmin ... (Tmax - 20 K) at interfaces during operation.
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
The supplied plug covers must
relative humidity remain in place over the unused
• with condensation acc. to 100 %; RH including condensation/ interfaces during operation.
IEC 60068-2-38 maximum frost (no commissioning coating for equipped printed circuit Yes; Class 2 for high availability
when condensation is present), board acc. to EN 61086
horizontal installation
type of coating protection against Yes; Protection of the type 1
chemical resistance to commercially Yes; incl. airborne diesel and oil pollution according to EN 60664-3
available cooling lubricants droplets
type of test of the coating Yes; Coating discoloration during
resistance to biologically active acc. to MIL-I-46058C service life possible
substances
product conformity of the coating Yes; Conformal coating, class A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal Qualification and Performance of
spores (excluding fauna), Electrical Insulating Compound for
Class 3B3 on request Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and IPC-CC-830A
dry rot spores (excluding fauna) protection class IP IP20
In a station for the S7-CPU, the new SIPLUS communication RJ45 plug-in connector for
Industrial Ethernet with a rugged
module TIM 3V-IE DNP3 V3.0 (TeleControl Interface Module) metal housing and integrated
handles the data exchange with the assigned master system insulation displacement contacts
SIMATIC PCS 7 TeleControl V8.0 using the open DNP3 protocol. for connecting Industrial Ethernet
In addition, the V3.0 module now also supports master and node FC installation cables;
functionality. with 180° cable outlet;
for network components and
• With the S7-300 housing, the module can be fully integrated CPs/CPUs with Industrial Ethernet
into the S7-300 system interface
• 1 pack = 1 unit 6AG1901-1BB10-7AA0
• The module has an RS232 interface for the connection of an -40 ... +70 °C, exposure to media
external modem for data transmission via a conventional WAN
or the connection of a Modbus RTU slave to an S7-300 system IE FC stripping tool 6GK1901-1GA00
• The RJ45 port is used for data transmission via IP-based Preadjusted stripping tool
for fast stripping of the
networks Industrial Ethernet FC cables
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were adopted from the
respective standard products. SIPLUS extreme-specific
information was added.
■ Technical specifications
Article number 6AG1803-3BA00-7AA0 Article number 6AG1803-3BA00-7AA0
Based on 6NH7803-3BA00-0AA0 Based on 6NH7803-3BA00-0AA0
product type designation SIPLUS NET TIM 3V-IE DNP3 product type designation SIPLUS NET TIM 3V-IE DNP3
ambient conditions resistance to chemically active
ambient temperature substances
• during operation -25 ... +70 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
incl. salt spray in accordance
• during storage -40 ... +70 °C with EN 60068-2-52 (Severity 3).
• during transport -40 ... +70 °C The supplied plug covers must
remain in place on the unused
installation altitude at height above 5 000 m interfaces during operation.
sea level maximum
• conformity acc. to EN 60721-3-6 Yes
ambient condition relating to Tmin ... Tmax at
ambient temperature - air pressure -
installation altitude
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
resistance to mechanically active
substances 5
Tmin ... (Tmax - 10 K) at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
795 hPa ... 658 hPa The supplied plug covers must
(+2 000 m ... +3 500 m) // remain in place over the unused
Tmin ... (Tmax - 20 K) at interfaces during operation.
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
The supplied plug covers must
relative humidity remain in place over the unused
• with condensation acc. to 100 %; RH including condensation/ interfaces during operation.
IEC 60068-2-38 maximum frost (no commissioning coating for equipped printed circuit Yes; Class 2 for high availability
when condensation is present), board acc. to EN 61086
horizontal installation
type of coating protection against Yes; Protection of the type 1
chemical resistance to commercially Yes; incl. airborne diesel and oil pollution according to EN 60664-3
available cooling lubricants droplets
type of test of the coating Yes; Coating discoloration during
resistance to biologically active acc. to MIL-I-46058C service life possible
substances
product conformity of the coating Yes; Conformal coating, class A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal Qualification and Performance of
spores (excluding fauna), Class 3B3 Electrical Insulating Compound for
on request Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and IPC-CC-830A
dry rot spores (excluding fauna) protection class IP IP20
■ Technical specifications
Article number 6AG1803-4BA00-7AA0 Article number 6AG1803-4BA00-7AA0
Based on 6NH7803-4BA00-0AA0 Based on 6NH7803-4BA00-0AA0
product type designation SIPLUS NET TIM 4R-IE DNP3 product type designation SIPLUS NET TIM 4R-IE DNP3
ambient conditions resistance to chemically active
ambient temperature substances
• during operation -25 ... +70 °C • conformity acc. to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %)
incl. salt spray in accordance
• during storage -40 ... +70 °C with EN 60068-2-52 (Severity 3).
• during transport -40 ... +70 °C The supplied plug covers must
remain in place on the unused
installation altitude at height above 5 000 m interfaces during operation.
sea level maximum
• conformity acc. to EN 60721-3-6 Yes
ambient condition relating to Tmin ... Tmax at
ambient temperature - air pressure -
installation altitude
1 140 hPa ... 795 hPa
(-1 000 m ... +2 000 m) //
resistance to mechanically active
substances 5
Tmin ... (Tmax - 10 K) at • conformity acc. to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust.
795 hPa ... 658 hPa The supplied plug covers must
(+2 000 m ... +3 500 m) // remain in place over the unused
Tmin ... (Tmax - 20 K) at interfaces during operation.
658 hPa ... 540 hPa
(+3 500 m ... +5 000 m) • conformity acc. to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust.
The supplied plug covers must
relative humidity remain in place over the unused
• with condensation acc. to 100 %; RH including condensation/ interfaces during operation.
IEC 60068-2-38 maximum frost (no commissioning coating for equipped printed circuit Yes; Class 2 for high availability
when condensation is present), board acc. to EN 61086
horizontal installation
type of coating protection against Yes; Protection of the type 1
chemical resistance to commercially Yes; incl. airborne diesel and oil pollution according to EN 60664-3
available cooling lubricants droplets
type of test of the coating Yes; Coating discoloration during
resistance to biologically active acc. to MIL-I-46058C service life possible
substances
product conformity of the coating Yes; Conformal coating, class A
• conformity acc. to EN 60721-3-3 Yes; Class 3B2 mold and fungal Qualification and Performance of
spores (excluding fauna), Electrical Insulating Compound for
Class 3B3 on request Printed Board Assemblies acc. to
• conformity acc. to EN 60721-3-6 Yes; Class 6B2 mold, fungal and IPC-CC-830A
dry rot spores (excluding fauna) protection class IP IP20
5 Digital outputs
Number of digital outputs 16; LEDs
Potential separation
Potential separation digital inputs
• between the channels and No
backplane bus
Potential separation digital outputs
• Simulator module for program testing during commissioning • between the channels and No
and ongoing operation backplane bus
Dimensions
• For the simulation of sensor signals using switches
Width 40 mm
• For display of signal conditions on the outputs using LED
Height 125 mm
• Simulation of Depth 120 mm
- 16 inputs or
Weights
- 16 outputs or
- 8 inputs and 8 outputs Weight, approx. 190 g
• Function can be directly adjusted on the module using a
screwdriver
Front connectors
20-pin, with screw contacts
• 1 unit 6ES7392-1AJ00-0AA0
• 100 units 6ES7392-1AJ00-1AB0
20-pin, with spring-loaded contacts
• 1 unit 6ES7392-1BJ00-0AA0
• 100 units 6ES7392-1BJ00-1AB0
40-pin, with screw contacts
• 1 unit 6ES7392-1AM00-0AA0
• 100 units 6ES7392-1AM00-1AB0
40-pin, with spring-loaded contacts
• 1 unit
• 100 units
6ES7392-1BM01-0AA0
6ES7392-1BM01-1AB0
5
Front door, elevated design 6ES7328-0AA00-7AA0
e.g. for 32 channel modules;
enables connection of
1.3 mm2/16 AWG wires
Front door, higher version, 6ES7328-7AA10-0AA0
• For the simple and user-friendly connection of sensors and for F-modules
actuators to the S7-300 I/O modules
For F-modules; for connecting
• For maintaining the wiring when replacing modules 1.3 mm2/16 AWG wires; wiring
("permanent wiring") diagram and labels in yellow
• With mechanical coding to avoid errors when replacing
modules
■ Overview
Wiring of SIMATIC S7 I/O modules with the sensors/actuators
is a significant factor with respect to time/cost overhead,
configuring, control cabinet installation, procurement and ease
of service.
With SIMATIC TOP connect system cabling, it is simple and
quick to establish a reliable connection for your SIMATIC S7-300
or ET 200M.
With the TIA Selection Tool, a mouse click is all that is required
to configure the connection from the SIMATIC S7 module to
the I/O. The program automatically checks for plausibility and
generates a parts list for the selected connection components
5 that can then be ordered in the Industry Mall.
More information can be found on the Internet at
http://www.siemens.com/tia-selection-tool
■ Design
Two cabling variants are available for a wide range of control cabinet concepts:
Fully modular connection
Each component is individually inserted. Connection errors are thus practically excluded and installation
overhead is minimized. Systematic connection of the
The system consists of: SIMATIC system. The assembly work for the connecting cables
• Front connector module is drastically reduced thanks to the use of pre-assembled cables
• Connecting cable sold by the meter.
• Terminal modules in the following versions: basic module,
signal module and function module
zpth{pjGz^TZWWVG
G mGGGGpVvGS
G jGGG
G
l{GYWWt GGG[GSGGG GGG
G z
jG G
G
OTGGGG G
GG
GWU\GGGXWGP
Flexible connection
Consisting of:
• Front connector with screw-type or crimp connection
6,0$7,&վ6
:LUHGIURQWFRQQHFWRU
• Front connector with fixed single cores (706 IRU','2PRGXOH
• Single cores also available with UL/CSA-certified cores
The blue wires are numbered sequentially and can be routed
direct to each element in the control cabinet. The numbering of RU
the single cores corresponds to the coding of the front connector IUHHZLUHHQGV
contacts.
In comparison to conventional single wiring, there is a cost SIMATIC TOP connect for S7-300/ET200M, flexible connection
saving of 50% for assembly, since the single cores that have
already been checked on the connector are fixed.
This eliminates the time-consuming assembly of up to
40 individual wires per module.
■ Overview
The fully modular connection for connecting to the digital
I/O modules of the SIMATIC S7-300 or ET 200M consists of
modified front connectors, called front connector modules,
preassembled connecting cables of various lengths, and
terminal modules. Suitable components can be selected for the
application in question and joined by means of simple plug-in
connections. The terminal modules are used instead of conven-
tional terminal blocks and act as the interface to the sensors and
actuators.
5
■ Benefits
• Front connector module, connecting cable and terminal • Distribution of digital signals by byte or quadruple byte
module are easy to plug in • Each component can be replaced individually
• Fast, low-cost wiring • Pre-assembled cables can be used in different lengths
• For digital and analog signals, supply voltage can be
connected to the front plug-in module or terminal module
• Reduction in wiring errors, clear control cabinet wiring
■ Design
Front connector module Terminal modules are available for two different connection
methods: with push-in or screw-type terminals. The potential can
Modified front connectors, called front connector modules, be fed in at the terminal module or at the front connector module.
are available for connecting to the module. These are plugged
into the module to be wired instead of the front connector. If other voltage or power levels are required in the field, the ter-
Many different front connector module versions, for digita minal module for TPRo or TPOo output signals is used. For the
l I/O modules, 24 V 2-ampère modules or analog I/O modules. TPRo terminal module, relays are used for the implementation.
The connecting cables are plugged into these front connector For the TPOo terminal module, optocouplers are used for the
modules. implementation. This converts the 24 V DC output signal simply
and reliably to another voltage or power level. If 230 V AC or
Connecting cable 110 V AC input signals have to be transmitted to the controller
There are different versions of the connecting cable. in the field, a terminal module with relay TPRi is available that
simply converts the 230/110 V AC signal to 24 V DC. This means
As a pre-assembled 16-pin or 50-pin round cable that there is always the same voltage level on the module side.
(shielded or unshielded) it is available in lengths up to 10 m.
Use with optocouplers for the TPRo relay modules
When assembled, there are one or two insulation displacement
connectors (female ribbon connectors) at both ends of the If higher switching frequencies of the relay terminal module are
cable. required for the output signals, the relay can simply be replaced
with an optocoupler (note technical specifications) in order to
The connecting cable connects the front connector module increase the switching frequency.
with the terminal module.
Shield plate
Terminal module
The shield plate is latched onto the terminal module for 3-core
The system has both digital and analog terminal modules for initiators or optionally onto the terminal module for analog
connecting the I/O signals. These are snapped onto the DIN rail. signals and then snapped onto the DIN rail with the terminal
The terminal modules with basic or signal functionality are module. With the shield connection clamps, optimal shield con-
available in 1-byte or 4-byte versions. nection is achieved between the shielded round-sheath ribbon
cable or the shielded field cables and the grounded DIN rail.
zpth{pjGz^TZWWVG
G mGGGGpVvGS
G jGGG
G
l{GYWWt GGG[GSGGG GGG
G z
jG G
G
OTGGGG G
GG
GWU\GGGXWGP
■ Technical specifications Front connector Front connector module SIMATIC TOP connect,
connection for potential infeed
Technical data of front connector module Spring Screw
connection connection
Rated operating voltage 24 VDC
Modules up to 8 connections
Max. permissible operating voltage 60 V DC
Connectable cable cross-sections
Max. permissible continuous current 1A • solid cables No
• per connector pin
• flexible cables with/without wire end 0.25 to 0.75 mm2
Max. permissible summation current 4 A/byte ferrule
Permissible ambient temperature 0 to + 60°C Number of cables per connection 1 or a combination of 2 wires up to
0.75 mm2 (total) in a common wire
Test voltage 0.5 kV, 50 Hz, 60 sec. end ferrule
Air gaps and creepage distances IEC 664 (1980), Max. diameter of the cable insulation 2.0 mm
IEC 664 A (1981),
5 in accordance with
DIN VDE 0110 (01.89),
overvoltage class II,
Stripping length of the cables
• without insulating collar 6 mm
• with insulating collar -
pollution degree 2
Wire-end ferrules in acc. with DIN 46228
Wiring rules for front connector modules • without insulating collar Form A; 5 to 7 mm long
• with insulating collar 0.25 to 1.0 mm2 -
Front connector module SIMATIC TOP connect,
• with insulating collar 1.5 mm2 -
connection for potential infeed
Blade width of the screwdriver 3.5 mm (cylindrical shape)
Spring Screw
connection connection Tightening torque for connecting - 0.4 to 0.7 Nm
the cables
Modules up to 4 connections
Connectable cable cross-sections
• solid cables No
• flexible cables with/without wire end 0,25 to 1.5 mm2
ferrule
■ Technical specifications Connecting cable
Number of wires per connection 1 or a combination of 2 conductors Technical specifications of
up to 1.5 mm2 (total) in a common connecting cable from SIMATIC S7 to connection module
wire end ferrule
Operating voltage 60 V DC
Max. diameter of the cable insulation 3.1 mm
Continuous current 1A
Stripping length of the cables per signal conductor
• without insulating collar 6 mm Max. total current 4 A/byte
• with insulating collar -
Operating temperature 0 to +60 °C
Wire-end ferrules in acc. with DIN 46228
• without insulating collar Form A; 5 to 7 mm long Outer diameter of pre-assembled Approx. 6.5/7.0
round cable in mm
• with insulating collar - unshielded/shielded (16-pole)
0.25 to 1.0 mm2
• with insulating collar 1.5 mm2 -
Blade width of the screwdriver 3.5 mm (cylindrical shape)
Tightening torque for connecting - 0.4 to 0.7 Nm
the cables
5
(digital 2 x 8 I/O) • Screw terminals 6ES7921-3AG00-0AA0
Power supply via Front connector module 40-pin
• Spring-loaded terminals 6ES7921-3AA00-0AA0 (analog)
• Screw terminals 6ES7921-3AB00-0AA0 Power supply via
Front connector module • Spring-loaded terminals 6ES7921-3AF20-0AA0
(digital 4 x 8 I/O) • Screw terminals 6ES7921-3AG20-0AA0
Power supply via
• Spring-loaded terminals 6ES7921-3AA20-0AA0
• Screw terminals 6ES7921-3AB20-0AA0
1)
The terminal assignments of these front connector modules are
unambiguous, so dimension drawings can be omitted. The dimension
drawings for these front connector modules can be found under
"Wiring of S7-300 analog modules" in the Industry Mall.
Connecting cables
Connecting cables Version 4 x 16 to 1 x 50-pin,
for SIMATIC S7-300 0.14 mm2
Pre-assembled round cable Unshielded
16-pin, 0.14 mm2 • 0.5 m 6ES7923-5BA50-0EB0
• 1.0 m 6ES7923-5BB00-0EB0
Unshielded • 1.5 m 6ES7923-5BB50-0EB0
• 0.5 m 6ES7923-0BA50-0CB0 • 2.0 m 6ES7923-5BC00-0EB0
• 1.0 m 6ES7923-0BB00-0CB0 • 2.5 m 6ES7923-5BC50-0EB0
• 1.5 m 6ES7923-0BB50-0CB0 • 3.0 m 6ES7923-5BD00-0EB0
• 2.0 m 6ES7923-0BC00-0CB0 • 4.0 m 6ES7923-5BE00-0EB0
• 2.5 m 6ES7923-0BC50-0CB0 • 5.0 m 6ES7923-5BF00-0EB0
• 3.0 m 6ES7923-0BD00-0CB0 • 6.5 m 6ES7923-5BG50-0EB0
• 4.0 m 6ES7923-0BE00-0CB0 • 8.0 m 6ES7923-5BJ00-0EB0
• 5.0 m 6ES7923-0BF00-0CB0 • 10.0 m 6ES7923-5CB00-0EB0
• 6.5 m 6ES7923-0BG50-0CB0
• 8.0 m 6ES7923-0BJ00-0CB0
• 10.0 m 6ES7923-0CB00-0CB0
Shielded
• 1.0 m 6ES7923-0BB00-0DB0
• 2.0 m 6ES7923-0BC00-0DB0
• 2.5 m 6ES7923-0BC50-0DB0
• 3.0 m 6ES7923-0BD00-0DB0
• 4.0 m 6ES7923-0BE00-0DB0
• 5.0 m 6ES7923-0BF00-0DB0
• 6.5 m 6ES7923-0BG50-0DB0
• 8.0 m 6ES7923-0BJ00-0DB0
• 10.0 m 6ES7923-0CB00-0DB0
Terminal modules
Terminal module TP1 Terminal module TPRi
For 1-wire connection, Relay module for 8 outputs
for 16-pin connecting cables (230 V AC), relay as normally open
• Push-in terminals without LEDs 6ES7924-0AA20-0AC0 contact
• Screw-type terminals without 6ES7924-0AA20-0AA0 • Push-in terminals with LEDs 6ES7924-0BE20-0BC0
LEDs • Screw-type terminals with LEDs 6ES7924-0BE20-0BA0
• Push-in terminals with LEDs 6ES7924-0AA20-0BC0 Terminal module TPOo
• Screw-type terminals with LEDs 6ES7924-0AA20-0BA0
Optocoupler module
For 1-wire connection, for 8 outputs (max. 24 V DC/4 A)
for 50-pin connecting cables • Push-in terminals with LEDs 6ES7924-0BF20-0BC0
Front connector
with single wires for
16-channel digital modules
SIMATIC S7-300, 20 x 0.5 mm2
Core type H05V-K
Screw version
Packaging unit: 1 unit
Length:
• 2.5 m 6ES7922-3BC50-0AB0
• 3.2 m 6ES7922-3BD20-0AB0
•5m 6ES7922-3BF00-0AB0
• Custom lengths On request
Packaging unit: 5 units
Length:
5
• 2.5 m 6ES7922-3BC50-5AB0
• 3.2 m 6ES7922-3BD20-5AB0
• 5.0 m 6ES7922-3BF00-5AB0
Crimp version
Packaging unit: 1 unit
Flexible connection enables fast, direct connection of the Length:
SIMATIC S7-300/ET 200 M input/output modules to the individual • 2.5 m 6ES7922-3BC50-0AF0
elements in the control cabinet. • 3.2 m 6ES7922-3BD20-0AF0
Attached single cores reduce the wiring outlay. • 5.0 m 6ES7922-3BF00-0AF0
• Custom lengths On request
Wire cross-sections of 0.5 mm2 allow higher currents, too.
Core type UL/CSA-certified
■ Integration
Use of the 20-pole front connector with
• 16-channel signal modules
• Function modules
• CPU 312 IFM
Use of the 40-pole front connector with
• 32-channel signal modules
• Compact CPUs
■ Technical specifications
Article number 6ES7307-1BA01-0AA0 6ES7305-1BA80-0AA0 6ES7307-1EA01-0AA0 6ES7307-1EA80-0AA0 6ES7307-1KA02-0AA0
Product PS 307 PS 305 Outdoor PS 307 PS 307 Outdoor PS 307
Power supply, type 24 V/2 A 24 V/2 A 24 V/5 A 24 V/5 A 24 V/10 A
Input
Input 1-phase AC DC voltage 1-phase AC 1-phase AC 1-phase AC
• Note Automatic range Automatic range Set by means of Automatic range
selection selection selector switch on the selection
device
supply voltage
• 1 at AC rated value 120 V 120 V 120 V 120 V
• 2 at AC rated value 230 V 230 V 230 V 230 V
• at DC 24 ... 110 V
input voltage
• 1 at AC 85 ... 132 V 85 ... 132 V 93 ... 132 V 85 ... 132 V
• 2 at AC 170 ... 264 V 170 ... 264 V 187 ... 264 V 170 ... 264 V
• at DC 16.8 ... 138 V
Wide-range input No Yes No No No
Overvoltage resistance 2.3 × Vin rated, 1.3 ms 154 V; 0.1 s 2.3 × Vin rated, 1.3 ms 2.3 × Vin rated, 1.3 ms 2.3 × Vin rated, 1.3 ms
Mains buffering at Vin = 93/187 V at Vin rated at Vin = 93/187 V at Vin = 93/187 V at Vin = 93/187 V
Mains buffering at Iout rated, min. 20 ms; 10 ms; at Vin rated 20 ms; 20 ms; 20 ms;
at Vin = 93/187 V at Vin = 93/187 V at Vin = 93/187 V at Vin = 93/187 V
Rated line frequency 1 50 Hz 50 Hz 50 Hz 50 Hz
Rated line frequency 2 60 Hz 60 Hz 60 Hz 60 Hz
Rated line range 47 ... 63 Hz 47 ... 63 Hz 47 ... 63 Hz 47 ... 63 Hz
input current
• at rated input voltage 120 V 0.9 A 2.3 A 2.1 A 4.2 A
• at rated input voltage 230 V 0.5 A 1.2 A 1.2 A 1.9 A
• at rated input voltage 24 V 2.4 A
• at rated input voltage 110 V 0.6 A
■ Technical specifications
Article number 6ES7307-1BA01-0AA0 6ES7305-1BA80-0AA0 6ES7307-1EA01-0AA0 6ES7307-1EA80-0AA0 6ES7307-1KA02-0AA0
Product PS 307 PS 305 Outdoor PS 307 PS 307 Outdoor PS 307
Power supply, type 24 V/2 A 24 V/2 A 24 V/5 A 24 V/5 A 24 V/10 A
Switch-on current limiting (+25 °C), 22 A 20 A 20 A 45 A 55 A
max.
duration of inrush current limiting
at 25 °C
• maximum 3 ms 10 ms 3 ms 3 ms 3 ms
I²t, max. 1 A²·s 5 A²·s 1.2 A²·s 1.8 A²·s 3.3 A²·s
Built-in incoming fuse T 1.6 A/250 V T 6.3 A/250 V T 3,15 A/250 V T 3,15 A/250 V T 6.3 A/250 V
(not accessible) (not accessible) (not accessible) (not accessible) (not accessible)
■ Technical specifications
Article number 6ES7307-1BA01-0AA0 6ES7305-1BA80-0AA0 6ES7307-1EA01-0AA0 6ES7307-1EA80-0AA0 6ES7307-1KA02-0AA0
Product PS 307 PS 305 Outdoor PS 307 PS 307 Outdoor PS 307
Power supply, type 24 V/2 A 24 V/2 A 24 V/5 A 24 V/5 A 24 V/10 A
Closed-loop control
Dynamic mains compensation 0.1 % 0.3 % 0.1 % 0.3 % 0.1 %
(Vin rated ±15 %), max.
Dynamic load smoothing 0.8 % 2.5 % 1% 3% 2%
(Iout: 50/100/50 %), Uout ± typ.
Load step setting time 50 to 100%, 0.5 ms 2.5 ms 0.3 ms 0.2 ms
typ.
Load step setting time 100 to 50%, 0.5 ms 2.5 ms 0.3 ms 0.2 ms
5
typ.
setting time maximum 1 ms 5 ms 5 ms 0.1 ms
Protection and monitoring
Output overvoltage protection Additional control loop, Additional control loop, Additional control loop, Additional control loop, Additional control loop,
shutdown at < 28.8 V, shutdown at approx. shutdown at < 28.8 V, shutdown at approx. shutdown at < 28.8 V,
automatic restart 30 V, automatic restart automatic restart 30 V, automatic restart automatic restart
Current limitation 2.2 ... 2.6 A 3.3 ... 3.9 A 5.5 ... 6.5 A 5.5 ... 6.5 A 11 ... 12 A
property of the output short-circuit Yes Yes Yes Yes Yes
proof
Short-circuit protection Electronic shutdown, Electronic shutdown, Electronic shutdown, Electronic shutdown, Electronic shutdown,
automatic restart automatic restart automatic restart automatic restart automatic restart
enduring short circuit current
RMS value
• maximum 2A 2A 7A 5A 12 A
Overload/short-circuit indicator - - -
Safety
Primary/secondary isolation Yes Yes Yes Yes Yes
galvanic isolation Safety extra-low output Safety extra low Safety extra-low output Safety extra low Safety extra-low output
voltage Uout acc. to output voltage Vout voltage Uout acc. to output voltage Vout voltage Uout acc. to
EN 60950-1 and according to EN 60950-1 and according to EN 60950-1 and
EN 50178 EN 60950-1 and EN 50178 EN 60950-1 and EN 50178
EN 50178, creepage EN 50178, creepage
distances and distances and
clearances > 5 mm clearances > 5 mm
Protection class Class I Class I Class I Class I Class I
leakage current
• maximum 3.5 mA 3.5 mA 3.5 mA 3.5 mA
• typical 0.5 mA 0.5 mA 0.3 mA 0.6 mA
Degree of protection (EN 60529) IP20 IP20 IP20 IP20 IP20
Approvals
CE mark Yes Yes Yes Yes Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, UL-Listed (UL 508), cULus-Listed (UL 508, UL-Listed (UL 508), cULus-Listed (UL 508,
CSA C22.2 No. 142), File E143289, CSA CSA C22.2 No. 142), File E143289, CSA CSA C22.2 No. 142),
File E143289 (CSA C22.2 No. 142) File E143289 (CSA C22.2 No. 142) File E143289
Explosion protection ATEX (EX) II 3G Ex nA - ATEX (EX) II 3G Ex nA - ATEX (EX) II 3G Ex nA
II T4; cULus (ANSI/ISA II T4; cULus (ANSI/ISA II T4; cULus (ANSI/ISA
12.12.01, CSA C22.2 12.12.01, CSA C22.2 12.12.01, CSA C22.2
No.213) Class I, Div. 2, No.213) Class I, Div. 2, No.213) Class I, Div. 2,
Group ABCD, T4, Group ABCD, T4, Group ABCD, T4,
File E330455 File E330455 File E330455
certificate of suitability NEC Class 2 No No No No No
FM approval Class I, Div. 2, - Class I, Div. 2, - Class I, Div. 2,
Group ABCD, T4 Group ABCD, T4 Group ABCD, T4
CB approval No No No No No
certificate of suitability EAC approval Yes Yes Yes Yes Yes
Marine approval In S7-300 system - In S7-300 system - In S7-300 system
EMC
Emitted interference EN 55022 Class B EN 55011 Class A EN 55022 Class B EN 55011 Class A EN 55022 Class B
Supply harmonics limitation not applicable not applicable EN 61000-3-2 - EN 61000-3-2
Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
■ Technical specifications
Article number 6ES7307-1BA01-0AA0 6ES7305-1BA80-0AA0 6ES7307-1EA01-0AA0 6ES7307-1EA80-0AA0 6ES7307-1KA02-0AA0
Product PS 307 PS 305 Outdoor PS 307 PS 307 Outdoor PS 307
Power supply, type 24 V/2 A 24 V/2 A 24 V/5 A 24 V/5 A 24 V/10 A
environmental conditions
ambient temperature
• during operation 0 ... 60 °C -25 ... +70 °C 0 ... 60 °C -25 ... +70 °C 0 ... 60 °C
- Note with natural convection with natural convection with natural convection with natural convection with natural convection
• during transport -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
• during storage -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
Humidity class according to Climate class 3K3, Climate class 3K5, Climate class 3K3, Climate class 3K5, Climate class 3K3,
EN 60721 5 … 95% transient condensa- 5 … 95% transient condensa- 5 … 95%
5 Mechanics
no condensation tion permitted no condensation tion permitted no condensation
Connection technology screw-type terminals screw-type terminals screw-type terminals screw-type terminals screw-type terminals
Connections
• Supply input L, N, PE: L+1, M1, PE: L, N, PE: 1 screw L, N, PE: L, N, PE:
1 screw terminal each 1 screw terminal each terminal each for 1 screw terminal each 1 screw terminal each
for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm² 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm² for 0.5 ... 2.5 mm²
single-core/ single-core/ single-core/ single-core/ single-core/
finely stranded finely stranded finely stranded finely stranded finely stranded
• Output L+, M: 2 screw L+, M: 3 screw L+, M: 3 screw L+, M: 3 screw L+, M: 4 screw
terminals each for terminals each for terminals each for terminals each for terminals each for
0.5 ... 2.5 mm² 0.5 ... 2.5 mm² 0.5 ... 2.5 mm² 0.5 ... 2.5 mm² 0.5 ... 2.5 mm²
• Auxiliary - - - - -
width of the enclosure 40 mm 80 mm 60 mm 80 mm 80 mm
height of the enclosure 125 mm 125 mm 125 mm 125 mm 125 mm
depth of the enclosure 120 mm 120 mm 120 mm 120 mm 120 mm
required spacing
• top 40 mm 50 mm 40 mm 50 mm 40 mm
• bottom 40 mm 50 mm 40 mm 50 mm 40 mm
• left 0 mm 0 mm 0 mm 0 mm 0 mm
• right 0 mm 0 mm 0 mm 0 mm 0 mm
Weight, approx. 0.4 kg 0.57 kg 0.6 kg 0.57 kg 0.8 kg
product feature of the enclosure Yes Yes Yes Yes Yes
housing can be lined up
Installation Can be mounted onto Can be mounted onto Can be mounted onto Can be mounted onto Can be mounted onto
S7 rail S7 rail S7 rail S7 rail S7 rail
mechanical accessories Mounting adapter for Mounting adapter for Mounting adapter for Mounting adapter for Mounting adapter for
standard mounting rail standard mounting rail standard mounting rail standard mounting rail standard mounting rail
(6EP1971-1BA00) (6ES7390-6BA00- (6EP1971-1BA00) (6ES7390-6BA00- (6EP1971-1BA00)
0AA0) 0AA0)
MTBF at 40 °C 2 320 078 h 964 506 h 2 480 589 h 2 231 610 h 1 504 280 h
other information Specifications at rated Specifications at rated Specifications at rated Specifications at rated Specifications at rated
input voltage and input voltage and input voltage and input voltage and input voltage and
ambient temperature ambient temperature ambient temperature ambient temperature ambient temperature
+25 °C (unless +25 °C (unless +25 °C (unless +25 °C (unless +25 °C (unless
otherwise specified) otherwise specified) otherwise specified) otherwise specified) otherwise specified)
■ Technical specifications
Article number 6AG1305-1BA80-2AA0 6AG1307-1EA01-7AA0 6AG1307-1KA02-7AA0
Based on 6ES7305-1BA80-0AA0 6ES7307-1EA01-0AA0 6ES7307-1KA02-0AA0
SIPLUS S7-300 PS 305 2 A (EN50155) SIPLUS PS307 AC 120/230V / SIPLUS_PS307_10A
DC 24 V/5 A
Ambient conditions
Ambient temperature
during operation
• min. -25 °C; = Tmin -25 °C; = Tmin -25 °C; = Tmin
• max. 70 °C; = Tmax; for use on railway 70 °C; = Tmax; 60 °C @ UL/cUL, 70 °C; = Tmax; 60 °C @ UL/cUL,
vehicles according to EN 50155, the ATEX and FM use ATEX and FM use
rated temperature range -25 ... +55 °C
(T1) or 60 °C @ UL/UL hazardous use
5 Altitude during operation
applies
■ Technical specifications
Article number 6ES7360-3AA01-0AA0 6ES7361-3CA01-0AA0 6ES7365-0BA01-0AA0
Interf. mod. IM360 in CC, IM 361 Interface Module in ER, Interf. mod. IM365,
with K-BUS with K-Bus w/o K-BUS
Supply voltage
Rated value (DC)
• 24 V DC Yes
Input current
from supply voltage L+, max. 500 mA
from backplane bus 5 V DC, max. 350 mA 100 mA
Power loss
Power loss, typ. 2W 5W 0.5 W
Hardware configuration
Number of interfaces per CPU, max. 1 3 1; 1 pair
Dimensions
Width 40 mm 80 mm 40 mm
Height 125 mm 125 mm 125 mm
Depth 120 mm 120 mm 120 mm
Weights
Weight, approx. 225 g 505 g 580 g
• SIPLUS IM 365:
For configuration of 1 central controller and max. 1 expansion
unit
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.
■ Technical specifications
Article number 6AG1365-0BA01-2AA0 Article number 6AG1365-0BA01-2AA0
Based on 6ES7365-0BA01-0AA0 Based on 6ES7365-0BA01-0AA0
SIPLUS S7-300 IM365 SIPLUS S7-300 IM365
Ambient conditions Use on land craft, rail vehicles and
Ambient temperature special-purpose vehicles
during operation - to biologically active substances Yes; Class 5B2 mold, fungus and
• min. -25 °C; = Tmin according to EN 60721-3-5 dry rot spores (with the exception of
fauna); Class 5B3 on request
• max. 60 °C; = Tmax
- to chemically active substances Yes; Class 5C3 (RH < 75 %) incl.
Ambient temperature according to EN 60721-3-5 salt spray acc. to EN 50155 (ST2); *
during storage/transportation
- to mechanically active substances Yes; Class 5S3 incl. sand, dust; *
• min. -40 °C according to EN 60721-3-5
• max. 70 °C Use on ships/at sea
Altitude during operation - to biologically active substances Yes; Class 6B2 mold and fungal
relating to sea level according to EN 60721-3-6 spores (excluding fauna);
• Installation altitude above sea level, 5 000 m Class 6B3 on request
max. - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
• Ambient air temperature- Tmin ... Tmax at according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
barometric pressure-altitude 1 140 hPa ... 795 hPa (severity degree 3); *
(-1 000 m ... +2 000 m) // - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
Tmin ... (Tmax - 10 K) at according to EN 60721-3-6
795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // Usage in industrial process
Tmin ... (Tmax -20 K) at technology
658 hPa ... 540 hPa - Against chemically active Yes; Class 3
(+3 500 m ... +5 000 m) substances acc. to EN 60654-4 (excluding trichlorethylene)
Relative humidity - Environmental conditions for Yes; Level GX group A/B
• With condensation, 100 %; RH incl. condensation/frost process, measuring and control (excluding trichlorethylene;
tested in accordance (no commissioning under systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
with IEC 60068-2-38, max. condensation conditions) the limits of EN 60721-3-3 class 3C4
permissible); level LC3 (salt spray)
Resistance and level LB3 (oil)
Use in stationary industrial systems Remark
- to biologically active substances Yes; Class 3B2 mold, fungus and - Note regarding classification * The supplied plug covers must
according to EN 60721-3-3 dry rot spores (with the exception of of environmental conditions remain in place over the unused
fauna); Class 3B3 on request acc. to EN 60721, EN 60654-4 interfaces during operation!
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. and ANSI/ISA-71.04
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
Label sheets
for modules with 20-pin front
connector, DIN A4, for printing
with laser printer; 10 units
petrol 6ES7392-2AX00-0AA0
light-beige 6ES7392-2BX00-0AA0
yellow 6ES7392-2CX00-0AA0
red 6ES7392-2DX00-0AA0
for modules with 40-pin front
connector, DIN A4, for printing
with laser printer; 10 units
petrol 6ES7392-2AX10-0AA0
light-beige 6ES7392-2BX10-0AA0
yellow 6ES7392-2CX10-0AA0
red 6ES7392-2DX10-0AA0
■ Technical specifications
Labeling sheets for S7-300
Dimensions DIN A4
Labeling strips per sheet, 10
pre-perforated
Weight, approx. 0.1 kg
Notes
6/2 Overview
6/2 SIMATIC S7-400
6/5 I/O modules
Siemens ST 70 · 2021
© Siemens 2021
■ Overview
SIMATIC S7-400:
The powerful controller for system solutions in the
manufacturing and process industries
Within the controller family, the SIMATIC S7-400 is designed for
system solutions in the manufacturing and process automation
industry.
• The modularly designed S7-400H can be flexibly adapted to
your requirements. The redundant configuration further
increases system availability.
• An additional protective coating (conformal coating) on the
circuit board optimally protects the modules against external
influences and makes them durable.
• The S7-400H stands out thanks to its long-term availability.
• Safety engineering, SIMATIC F-systems and standard
6 automation can be integrated into a single automation system.
• The configuration of the distributed I/O of the S7-400 can be
modified during operation. In addition signal modules can be
removed and inserted while live (hot swapping). This makes it
very easy to expand the system or replace modules in the
event of a fault.
• Storage of the entire project data, including symbols and
comments, on the CPU simplifies service and maintenance
calls.
4)
— = cannot be used/not available also as SIPLUS extreme component for corrosive atmosphere/condensation
n = can be used/available
■ Overview
• The S7-400 is especially suitable for data-intensive tasks
in the process industry. High processing speeds and
deterministic response times guarantee short machine cycle
times on high-speed machines in the manufacturing industry.
The high-speed backplane bus of S7-400 ensures efficient
linking of central I/O modules.
• The S7-400 is used preferably to coordinate complete plants
and to control lower-level devices/stations; this is guaranteed
by the high communication power and the integral interfaces.
• The performance is scalable thanks to a graded range of
CPUs; Interfaces for the PROFIBUS/PROFINET connection
ensure optimal connectivity.
• To further increase ruggedness and durability in the harsh
everyday industrial environment, the S7-400 has a "G3"
conformal coating.
SIMATIC S7-400, CPU 412-1 / 412-2 412-2 PN4) 414-2 / 414-3 414-3 PN/DP4) 416-2 / 416-34) 416-3 PN/DP4) 417-44)
2) 3)
Work memory 512KB/ 1 MB 2/4 MB 4 MB 8/16 MB 16 MB 32 MB
11) MB
Processing times (ns)
Bit/word/ 31.25/31.25/ 31.25/31.25/ 18.75/18.75/ 18.75/18.75/ 12.5/12.5/ 12.5/12.5/ 7.5/7.5/
fixed point/floating point 31.25/62.5 31.25/62.5 18.75/37.5 18.75/37.5 12.5/25 12.5/25 7.5/15
Timers/counters 2048/2048 2048/2048 2048/2048 2048/2048 2048/2048 2048/2048 2048/2048
Address range
Digital inputs/outputs 32768 each 32768 each 65536 each 65536 each 131072 each 131072 each 131072 each
Analog inputs/outputs 2048 each 2048 each 4096 each 4096 each 8192 each 8192 each 8192 each
DP interfaces
Number of MPI/DP interfaces 1 1 1 1 1 1 1
Number of DP interfaces — / 11) — 1 — 1 1 1
Number of DP slaves per 32 32 32 32 32 32 32
MPI/DP
Number of DP slaves per DP 64 — 96 each 125 each 125 each 125 each 125 each
Plug-in interface modules — — — / 1 x DP2) 1 x DP — / 1 x DP3) 1 x DP 2 x DP
Data set gateway n n n n n n n
PN interfaces
Number of PN interfaces — 1 (2 ports) — 1 (2 ports) — 1 (2 ports) —
PROFINET IO — n — n — n —
PROFINET with IRT — n — n — n —
PROFINET CBA — n — n — n —
TCP/IP — n — n — n —
UDP — n — n — n —
Web server — n — n — n —
ISO-on-TCP (RFC 1006) — n — n — n —
Mounting dimensions 25 x 290 x 219 25 x 290 x 219 25 x 290 x 219 50 x 290 x 219 25 x 290 x 219 50 x 290 x 219 50 x 290 x 219
W x H x D (mm) 50 x 290 x 2192) 50 x 290 x 2193)
■ Overview
• Safety engineering and standard automation can be
integrated into a single S7-400;.
• For demanding, safety-oriented automation in mechanical
engineering with S7 Distributed Safety.
• Many S7-400 components are also available in a SIPLUS
extreme version for extreme environmental conditions, e.g. for
use where there is a corrosive atmosphere/condensation. For
more detailed information, visit
www.siemens.com/siplus-extreme
■ Overview
Digital modules
SM 421 digital input module Article No.
• Digital inputs for the SIMATIC S7-400 16 inputs, 6ES7421-7BH01-0AB0
• For connecting switches and 2-wire proximity 24 V DC, with hardware/
switches (BEROs) diagnostics interrupt
Detailed information on SIMATIC S7-400, see 32 inputs, 24 V DC 6ES7421-1BL01-0AA0
Catalog ST 400 in Siemens Industry Online Support: 32 inputs, 120 V UC 6ES7421-1EL00-0AA0
www.siemens.com/industry-catalogs
16 inputs, 6ES7421-1FH20-0AA0
120/230 V UC,
inputs according to
IEC 1131-2 Type 2
16 inputs, 6ES7421-7DH00-0AB0
24 to 60 V UC,
with hardware/
diagnostics interrupt
SM 422 digital output module Article No. 6
• Digital outputs for the SIMATIC S7-400 16 outputs, 6ES7422-1FH00-0AA0
• For connecting solenoid valves, contactors, 120/230 V AC, 2 A
small-power motors, lamps and motor starters 6 outputs, 6ES7422-1HH00-0AA0
Detailed information on SIMATIC S7-400, see relay contacts
Catalog ST 400 in Siemens Industry Online Support: 16 outputs, 6ES7422-1BH11-0AA0
www.siemens.com/industry-catalogs 24 V DC, 2 A
32 outputs, 6ES7422-1BL00-0AA0
24 V DC, 0.5 A
32 outputs; 6ES7422-7BL00-0AB0
24 V DC, 0.5 A;
with diagnostics
Analog modules
SM 431 analog input module Article No.
• Analog inputs for the SIMATIC S7-400 16 inputs, non-floating, 6ES7431-0HH00-0AB0
• For connecting voltage sensors and current sensors, 13 bit
thermocouples, resistors and resistance 8 inputs, floating, 14 bit 6ES7431-1KF20-0AB0
thermometers
8 inputs, floating, 13 bit 6ES7431-1KF00-0AB0
• Resolution 13 to 16 bit
Detailed information on SIMATIC S7-400, see 8 inputs, floating, 14 bit, 6ES7431-1KF10-0AB0
Catalog ST 400 in Siemens Industry Online Support: with linearization
www.siemens.com/industry-catalogs 16 inputs, floating, 6ES7431-7QH00-0AB0
16 bit, hardware
interrupt capability
8 inputs, floating, 16 bit, 6ES7431-7KF00-0AB0
hardware interrupt
capability, for
thermocouples (I, U)
8 inputs, floating, 16 bit, 6ES7431-7KF10-0AB0
hardware interrupt
capability, for thermal
resistors
SM 432 analog output module Article No.
• Analog outputs for the SIMATIC S7-400 8 outputs, floating, 6ES7432-1HF00-0AB0
• For connecting analog actuators 13 bit
Detailed information on SIMATIC S7-400, see
Catalog ST 400 in Siemens Industry Online Support:
www.siemens.com/industry-catalogs
■ Overview
Function modules
FM 450-1 counter module Article No.
• Two-channel, intelligent counter module for simple With 2 channels, 6ES7450-1AP01-0AE0
counting tasks max. 500 kHz;
• For direct connection of incremental encoders for incremental
encoders
• Comparison function with 2 definable comparison
values
• Integrated digital outputs for outputting the reaction
on reaching the comparison values
Detailed information on SIMATIC S7-400, see
Catalog ST 400 in Siemens Industry Online Support:
www.siemens.com/industry-catalogs
6
FM 451 positioning module Article No.
The three-channel FM 451 positioning module takes For rapid traverse and 6ES7451-3AL00-0AE0
over the adjustment of mechanical axes for rapid creep speed drives
traverse/creep speed drives. The module is designed
for positioning adjusting and tooling axes, preferably
with standard motors, controlled via contactors or
frequency converters.
• Three-channel positioning module for rapid
traverse/creep speed drives
• 4 digital outputs per channel for motor control
• Incremental or synchronous-serial position feedback
Detailed information on SIMATIC S7-400, see
Catalog ST 400 in Siemens Industry Online Support:
www.siemens.com/industry-catalogs
■ Overview
Function modules
FM 455 controller module Article No.
The FM 455 controller module is the intelligent With 16 analog outputs 6ES7455-0VS00-0AE0
16-channel controller module for universal control for 16 continuous
tasks. It can be used, for example, for temperature controllers
control, pressure control, flow control or level control.
• Convenient online self-optimization for temperature
controls
• Ready-to-use controller structures
• 2 control algorithms
• 2 versions:
- FM 455 C as continuous controller
- FM 455 S as step or pulse controller
• With 16 analog outputs (FM 455 C) or
32 digital outputs (FM 455 S) for actuators
Detailed information on SIMATIC S7-400, see
Catalog ST 400 in Siemens Industry Online Support:
With 32 digital outputs
for 16 step or pulse
controllers
6ES7455-1VS00-0AE0
6
www.siemens.com/industry-catalogs
Notes
Distributed Controllers
Siemens ST 70 · 2021
© Siemens 2021
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1510SP-1 PN
• For high-performance control solutions using ET 200SP • Length 483 mm for 19" cabinets 6ES5710-8MA11
• Increase in availability of systems and machines • Length 530 mm 6ES5710-8MA21
for 600 mm cabinets
• PROFINET IO controller for up to 64 IO devices • Length 830 mm 6ES5710-8MA31
• PROFINET I-Device for connecting the CPU for 900 mm cabinets
as an intelligent PROFINET device with a SIMATIC or • Length 2 m 6ES5710-8MA41
non-Siemens PROFINET IO controller PE connection element 6ES7590-5AA00-0AA0
• PROFINET shared I-Device for 4 controllers for 2 000 mm DIN rail
• PROFINET IO IRT interface with integrated 3-port switch BusAdapter BA 2xRJ45 6ES7193-6AR00-0AA0
• OPC UA Server and Client (Data Access) as runtime option BusAdapter BA SCRJ/FC 6ES7193-6AP40-0AA0
for easy connection of the SIMATIC ET 200SP to non-Siemens Equipment labeling plate 6ES7193-6LF30-0AW0
devices/systems 10 sheets of 16 labels
• Optional PROFIBUS DP master for 125 PROFIBUS DP slaves Labeling strips
(with CM DP module 6ES7545-5DA00-0AB0)
500 labeling strips on roll, light gray, 6ES7193-6LR10-0AA0
• Optional PROFIBUS DP slave for inscription with thermal transfer
(with CM DP module 6ES7545-5DA00-0AB0) roll printer
• Configuration control (option handling) 500 labeling strips on roll, yellow, 6ES7193-6LR10-0AG0
• Integrated Motion Control functionalities for controlling for inscription with thermal transfer
roll printer
speed-controlled and positioning axes, support for external
encoders, output cams/cam tracks and probes 1 000 labeling strips DIN A4, light 6ES7193-6LA10-0AA0
gray, card, for inscription with laser
Note printer
SIMATIC Memory Card required for operation of the CPU. 1 000 labeling strips DIN A4, yellow, 6ES7193-6LA10-0AG0
card, for inscription with laser
The BusAdapter is not included in scope of supply and is to be printer
ordered separately.
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1510SP-1 PN
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1510SP-1 PN
■ Technical specifications
Article number 6ES7510-1DJ01-0AB0 Article number 6ES7510-1DJ01-0AB0
CPU 1510SP-1 PN, CPU 1510SP-1 PN,
100KB Prog./750KB Data 100KB Prog./750KB Data
General information 1. Interface
Product type designation CPU 1510SP-1 PN Interface types
Engineering with • RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V13 SP1 Update 4 via BusAdapter BA 2x RJ45
integrated from version (FW V1.8) or higher • Number of ports 3; 1. integr. + 2. via BusAdapter
Supply voltage • integrated switch Yes
Type of supply voltage 24 V DC • BusAdapter (PROFINET) Yes; compatible BusAdapters:
Memory BA 2x RJ45, BA 2x FC, BA 2x M12
Work memory Protocols
• integrated (for program) 100 kbyte • IP protocol Yes; IPv4
• integrated (for data) 750 kbyte • PROFINET IO Controller Yes
Load memory • PROFINET IO Device Yes
• Plug-in (SIMATIC Memory Card), 32 Gbyte • SIMATIC communication Yes
max. • Open IE communication Yes; Optionally also encrypted
CPU processing times • Web server Yes
7 for bit operations, typ.
for word operations, typ.
72 ns
86 ns
• Media redundancy Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0
for fixed point arithmetic, typ. 115 ns PROFINET IO Controller
for floating point arithmetic, typ. 461 ns Services
Counters, timers and their - PG/OP communication Yes
retentivity - Isochronous mode Yes
S7 counter - Direct data exchange Yes; Requirement: IRT and
• Number 2 048 isochronous mode (MRPD optional)
IEC counter - IRT Yes
• Number Any - PROFIenergy Yes; per user program
(only limited by the main memory) - Prioritized startup Yes; Max. 32 PROFINET devices
S7 times - Number of connectable 64; In total, up to 256 distributed I/O
• Number 2 048 IO Devices, max. devices can be connected via AS-i,
PROFIBUS or PROFINET
IEC timer
- Of which IO devices with IRT, max. 64
• Number Any
(only limited by the main memory) - Number of connectable 64
IO Devices for RT, max.
Data areas and their retentivity
- of which in line, max. 64
Flag
- Number of IO Devices that 8; in total across all interfaces
• Size, max. 16 kbyte can be simultaneously activated/
Address area deactivated, max.
I/O address area - Number of IO Devices per tool, 8
max.
• Inputs 32 kbyte; All inputs are in the
process image - Updating times The minimum value of the
update time also depends on
• Outputs 32 kbyte; All outputs are in the communication share set for
process image PROFINET IO, on the number of
Address space per module IO devices, and on the quantity of
configured user data
• Address space per module, max. 288 byte; For input and output data
respectively PROFINET IO Device
Address space per station Services
• Address space per station, max. 2 560 byte; for central inputs and - PG/OP communication Yes
outputs; depending on configuration; - Isochronous mode No
2 048 bytes for ET 200SP modules +
512 bytes for ET 200AL modules - IRT Yes
Time of day - PROFIenergy Yes; per user program
Clock - Shared device Yes
• Type Hardware clock - Number of IO Controllers with 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program
- Asset management record Yes; per user program
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1510SP-1 PN
■ Technical specifications
Article number 6ES7510-1DJ01-0AB0 Article number 6ES7510-1DJ01-0AB0
CPU 1510SP-1 PN, CPU 1510SP-1 PN,
100KB Prog./750KB Data 100KB Prog./750KB Data
2. Interface Ambient conditions
Interface types Ambient temperature
• RS 485 Yes; Via CM DP module during operation
• Number of ports 1 • horizontal installation, min. -25 °C; No condensation
Protocols • horizontal installation, max. 60 °C
• PROFIBUS DP master Yes • vertical installation, min. -25 °C; No condensation
• PROFIBUS DP slave Yes • vertical installation, max. 50 °C
• SIMATIC communication Yes Altitude during operation
relating to sea level
PROFIBUS DP master
• Installation altitude above sea level, 5 000 m; Restrictions for installation
• Number of DP slaves, max. 125; In total, up to 256 distributed max. altitudes > 2 000 m, see manual
I/O devices can be connected via
AS-i, PROFIBUS or PROFINET Configuration
Protocols Programming
Number of connections Programming language
• Number of connections, max. 96; via integrated interfaces of the - LAD Yes
Redundancy mode
CPU and connected CPs / CMs - FBD
- STL
Yes
Yes
7
Media redundancy - SCL Yes
- Media redundancy Yes; only via BusAdapter - GRAPH Yes
- MRP Yes; MRP Automanager according Know-how protection
to IEC 62439-2 Edition 2.0, • User program protection/ Yes
MRP Manager; MRP Client password protection
- MRP interconnection, supported Yes; as MRP ring node according to • Copy protection Yes
IEC 62439-2 Edition 3.0
• Block protection Yes
- MRPD Yes; Requirement: IRT
Access protection
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for
MRPD • protection of confidential Yes
configuration data
- Number of stations in the ring, 50
max. • Protection level: Write protection Yes
SIMATIC communication • Protection level: Yes
Read/write protection
• S7 routing Yes
• Protection level: Yes
OPC UA Complete protection
• OPC UA Client Yes Dimensions
• OPC UA Server Yes; Data access Width 100 mm
(read, write, subscribe), method call,
custom address space Height 117 mm
• Alarms and Conditions Yes Depth 75 mm
Supported technology objects Weights
Motion Control Yes; Note: The number of technology Weight, approx. 310 g
objects affects the cycle time of the
PLC program; selection guide via the
TIA Selection Tool
• Number of available Motion Control 800
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40
- per positioning axis 80
- per synchronous axis 160
- per external encoder 80
- per output cam 20
- per cam track 160
- per probe 40
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1512SP-1 PN
• For applications with medium requirements in terms of • Length 483 mm for 19" cabinets 6ES5710-8MA11
program scope and processing speed, for distributed • Length 530 mm 6ES5710-8MA21
configurations via PROFINET IO or PROFIBUS DP. for 600 mm cabinets
• Increase in availability of systems and machines • Length 830 mm 6ES5710-8MA31
for 900 mm cabinets
• PROFINET IO controller for up to 128 IO devices • Length 2 m 6ES5710-8MA41
• PROFINET I-device for connecting the CPU PE connection element 6ES7590-5AA00-0AA0
as an intelligent PROFINET device with a SIMATIC or for 2 000 mm DIN rail
third-party PROFINET IO controller BusAdapter BA 2xRJ45 6ES7193-6AR00-0AA0
• PROFINET shared I-device for 4 controllers BusAdapter BA 2xFC 6ES7193-6AF00-0AA0
• PROFINET IO IRT interface with integrated 3-port switch for increased vibration and
EMC loads
• Isochronous mode on PROFINET
BusAdapter BA 2xSCRJ 6ES7193-6AP00-0AA0
• With multiple communication options:
PG/OP communication, PROFINET IO, BusAdapter BA SCRJ/RJ45 6ES7193-6AP20-0AA0
open IE communication (TCP, ISO-on-TCP and UDP), BusAdapter BA SCRJ/FC 6ES7193-6AP40-0AA0
web server and S7 communication (with loadable FBs) BusAdapter BA 2xLC 6ES7193-6AG00-0AA0
• OPC UA Server and Client (data access) as runtime option BusAdapter BA LC/RJ45 6ES7193-6AG20-0AA0
for easy connection of the SIMATIC ET 200SP to third-party
devices/systems BusAdapter BA LC/FC 6ES7193-6AG40-0AA0
• Optional PROFIBUS DP master for 125 PROFIBUS DP slaves Equipment labeling plate 6ES7193-6LF30-0AW0
(with CM DP module 6ES7545-5DA00-0AB0) 10 sheets of 16 labels
• Optional PROFIBUS DP slave Labeling strips
(with CM DP module 6ES7545-5DA00-0AB0)
500 labeling strips on roll, light gray, 6ES7193-6LR10-0AA0
• Configuration control (option handling) for inscription with thermal transfer
roll printer
• Integrated motion control functionalities for controlling
speed-controlled and positioning axes, support for external 500 labeling strips on roll, yellow, 6ES7193-6LR10-0AG0
encoders, output cams/cam tracks and probes for inscription with thermal transfer
roll printer
Note 1 000 labeling strips DIN A4, light 6ES7193-6LA10-0AA0
SIMATIC Memory Card required for operation of the CPU. gray, card, for inscription with laser
printer
BusAdapter is not included in scope of supply and is to be
ordered separately. 1 000 labeling strips DIN A4, yellow, 6ES7193-6LA10-0AG0
card, for inscription with laser
printer
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1512SP-1 PN
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1512SP-1 PN
■ Technical specifications
Article number 6ES7512-1DK01-0AB0 Article number 6ES7512-1DK01-0AB0
CPU 1512SP-1 PN, 200KB CPU 1512SP-1 PN, 200KB
Prog./1MB Data Prog./1MB Data
General information 1. Interface
Product type designation CPU 1512SP-1 PN Interface types
Engineering with • RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V13 SP1 Update 4 via BusAdapter BA 2x RJ45
integrated from version (FW V1.8) or higher • Number of ports 3; 1. integr. + 2. via BusAdapter
Supply voltage • integrated switch Yes
Type of supply voltage 24 V DC • BusAdapter (PROFINET) Yes; compatible BusAdapters:
Memory BA 2x RJ45, BA 2x M12, BA 2x FC,
BA 2x LC, BA LC/RJ45, BA LC/FC,
Work memory BA 2x SCRJ, BA SCRJ/RJ45,
• integrated (for program) 200 kbyte BA SCRJ/FC,
• integrated (for data) 1 Mbyte Protocols
Load memory • IP protocol Yes; IPv4
• Plug-in (SIMATIC Memory Card), 32 Gbyte • PROFINET IO Controller Yes
max. • PROFINET IO Device Yes
CPU processing times • SIMATIC communication Yes
7 for bit operations, typ.
for word operations, typ.
48 ns
58 ns
• Open IE communication
• Web server
Yes; Optionally also encrypted
Yes
for fixed point arithmetic, typ. 77 ns • Media redundancy Yes; MRP Automanager according to
for floating point arithmetic, typ. 307 ns IEC 62439-2 Edition 2.0
Counters, timers and their PROFINET IO Controller
retentivity Services
S7 counter - PG/OP communication Yes
• Number 2 048 - Isochronous mode Yes
IEC counter - Direct data exchange Yes; Requirement: IRT and isochro-
• Number Any nous mode (MRPD optional)
(only limited by the main memory) - IRT Yes
S7 times - PROFIenergy Yes; per user program
• Number 2 048 - Prioritized startup Yes; Max. 32 PROFINET devices
IEC timer - Number of connectable 128; In total, up to 512 distributed I/O
• Number Any IO Devices, max. devices can be connected via AS-i,
(only limited by the main memory) PROFIBUS or PROFINET
Data areas and their retentivity - Of which IO devices with IRT, max. 64
Flag - Number of connectable 128
IO Devices for RT, max.
• Size, max. 16 kbyte
- of which in line, max. 128
Address area
- Number of IO Devices that 8; in total across all interfaces
I/O address area can be simultaneously activated/
• Inputs 32 kbyte; All inputs are in the deactivated, max.
process image - Number of IO Devices per tool, 8
• Outputs 32 kbyte; All outputs are in the max.
process image - Updating times The minimum value of the
Address space per module update time also depends on
communication share set for
• Address space per module, max. 288 byte; For input and output data
PROFINET IO, on the number of
respectively
IO devices, and on the quantity of
Address space per station configured user data
• Address space per station, max. 2 560 byte; for central inputs and PROFINET IO Device
outputs; depending on configuration;
Services
2 048 bytes for ET 200SP modules +
512 bytes for ET 200AL modules - PG/OP communication Yes
Time of day - Isochronous mode No
Clock - IRT Yes
• Type Hardware clock - PROFIenergy Yes; per user program
- Shared device Yes
- Number of IO Controllers with 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program
- Asset management record Yes; per user program
Distributed Controllers
based on ET 200SP
Standard CPUs
CPU 1512SP-1 PN
■ Technical specifications
Article number 6ES7512-1DK01-0AB0 Article number 6ES7512-1DK01-0AB0
CPU 1512SP-1 PN, 200KB CPU 1512SP-1 PN, 200KB
Prog./1MB Data Prog./1MB Data
2. Interface Ambient conditions
Interface types Ambient temperature
• RS 485 Yes; Via CM DP module during operation
• Number of ports 1 • horizontal installation, min. -25 °C; No condensation
Protocols • horizontal installation, max. 60 °C
• PROFIBUS DP master Yes • vertical installation, min. -25 °C; No condensation
• PROFIBUS DP slave Yes • vertical installation, max. 50 °C
• SIMATIC communication Yes Altitude during operation
relating to sea level
PROFIBUS DP master
• Installation altitude above sea level, 5 000 m; Restrictions for installation
• Number of DP slaves, max. 125; In total, up to 512 distributed I/O max. altitudes > 2 000 m, see manual
devices can be connected via AS-i,
PROFIBUS or PROFINET Configuration
Protocols Programming
Number of connections Programming language
• Number of connections, max. 128; via integrated interfaces of the - LAD Yes
Redundancy mode
CPU and connected CPs / CMs - FBD
- STL
Yes
Yes
7
Media redundancy - SCL Yes
- Media redundancy Yes; only via BusAdapter - GRAPH Yes
- MRP Yes; MRP Automanager according Know-how protection
to IEC 62439-2 Edition 2.0, • User program protection/ Yes
MRP Manager; MRP Client password protection
- MRP interconnection, supported Yes; as MRP ring node according to • Copy protection Yes
IEC 62439-2 Edition 3.0
• Block protection Yes
- MRPD Yes; Requirement: IRT
Access protection
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for
MRPD • protection of confidential Yes
configuration data
- Number of stations in the ring, 50
max. • Protection level: Write protection Yes
SIMATIC communication • Protection level: Yes
Read/write protection
• S7 routing Yes
• Protection level: Yes
OPC UA Complete protection
• OPC UA Client Yes Dimensions
• OPC UA Server Yes; Data access Width 100 mm
(read, write, subscribe), method call,
custom address space Height 117 mm
• Alarms and Conditions Yes Depth 75 mm
Supported technology objects Weights
Motion Control Yes; Note: The number of technology Weight, approx. 310 g
objects affects the cycle time of the
PLC program; selection guide via the
TIA Selection Tool
• Number of available Motion Control 800
resources for technology objects
• Required Motion Control resources
- per speed-controlled axis 40
- per positioning axis 80
- per synchronous axis 160
- per external encoder 80
- per output cam 20
- per cam track 160
- per probe 40
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Distributed Controllers
based on ET 200SP
SIPLUS standard CPUs
SIPLUS CPU 1510SP-1 PN
• Optional PROFIBUS DP master for 125 PROFIBUS DP slaves SIPLUS Mounting Kit ET 200SP 6AG1193-6AA00-0AA0
(with CM DP module 6ES7545-5DA00-0AB0) Mounting accessories for use with
increased mechanical vibration and
• Optional PROFIBUS DP slave shock loads.
(with CM DP module 6ES7545-5DA00-0AB0) Not approved for SIPLUS CPU
• Configuration control (option handling) 6AG1510-1DJ01-7AB0 and
BusAdapter BA 2xRJ45
• Integrated motion control functionalities for controlling
Other accessories See SIMATIC ET 200SP
speed-controlled and positioning axes, support for external CPU 1510SP-1 PN,
encoders page 7/2
Note
SIMATIC Memory Card required for operation of the CPU.
The BusAdapter is not included in the scope of supply and
is to be ordered separately.
No BusAdapter can be inserted with the variant for the
temperature range -40...+70 °C.
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
Distributed Controllers
based on ET 200SP
SIPLUS standard CPUs
SIPLUS CPU 1510SP-1 PN
■ Technical specifications
Article number 6AG1510-1DJ01-2AB0 6AG1510-1DJ01-7AB0
Based on 6ES7510-1DJ01-0AB0 6ES7510-1DJ01-0AB0
SIPLUS ET 200SP CPU 1510SP-1 PN SIPLUS ET 200SP CPU 1510SP-1 PN
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin
• horizontal installation, max. 60 °C; = Tmax 70 °C; = Tmax
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin
• vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
Relative humidity
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
7
• With condensation, tested in acc. 100 %; RH incl. condensation / frost (no commissioning 100 %; RH incl. condensation / frost (no commissioning
with IEC 60068-2-38, max. in bedewed state), horizontal installation in bedewed state), horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75%) incl. salt spray according to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (degree of severity 3). The supplied EN 60068-2-52 (severity degree 3); *
connector covers must remain on the unused interfaces
during operation!
- to mechanically active substances Yes; Class 3S4 incl. sand, dust. The supplied connector Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3 covers must remain on the unused interfaces during
operation!
- Against mechanical environmental Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-3 (6AG1193-6AA00-0AA0)
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores Yes; Class 6B2 mold, fungal and dry rot spores
according to EN 60721-3-6 (excluding fauna); Class 6B3 on request (excluding fauna)
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
- Against mechanical environmental Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-6 (6AG1193-6AA00-0AA0)
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and class 3C4 permissible); level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
Distributed Controllers
based on ET 200SP
SIPLUS standard CPUs
SIPLUS CPU 1512SP-1 PN
Distributed Controllers
based on ET 200SP
SIPLUS standard CPUs
SIPLUS CPU 1512SP-1 PN
■ Technical specifications
Article number 6AG1512-1DK01-2AB0 6AG1512-1DK01-7AB0
6ES7512-1DK01-0AB0 6ES7512-1DK01-0AB0
SIPLUS ET 200SP CPU 1512SP-1 PN SIPLUS ET 200SP CPU 1512SP-1 PN
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin
• horizontal installation, max. 60 °C; = Tmax 70 °C; = Tmax
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin
• vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
barometric pressure-altitude (-1 000 m ... +2 000 m) // (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa
(+2 000 m ... +3 500 m) // (+2 000 m ... +3 500 m) //
Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa
Relative humidity
(+3 500 m ... +5 000 m) (+3 500 m ... +5 000 m)
7
• With condensation, tested in acc. 100 %; RH incl. condensation / frost (no commissioning 100 %; RH incl. condensation / frost (no commissioning
with IEC 60068-2-38, max. in bedewed state), horizontal installation in bedewed state), horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75%) incl. salt spray according Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 to EN 60068-2-52 (degree of severity 3). The supplied EN 60068-2-52 (severity degree 3); *
connector covers must remain on the unused interfaces
during operation!
- to mechanically active substances Yes; Class 3S4 incl. sand, dust. The supplied connector Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3 covers must remain on the unused interfaces during
operation!
- Against mechanical environmental Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-3 (6AG1193-6AA00-0AA0)
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold, fungal and dry rot spores
according to EN 60721-3-6 Class 6B3 on request (excluding fauna)
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
- Against mechanical environmental Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-6 (6AG1193-6AA00-0AA0)
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance of Yes; Conformal coating, Class A Yes; Conformal coating, Class A
Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1510SP F-1 PN
• For high-performance control solutions using ET 200SP • Length 483 mm for 19" cabinets 6ES5710-8MA11
• Increase in availability of systems and machines • Length 530 mm 6ES5710-8MA21
for 600 mm cabinets
• Supports PROFIsafe in centralized and distributed • Length 830 mm 6ES5710-8MA31
configuration for 900 mm cabinets
• PROFINET IO controller for up to 64 IO devices • Length 2 m 6ES5710-8MA41
• PROFINET I-Device for connecting the CPU PE connection element 6ES7590-5AA00-0AA0
as an intelligent PROFINET device with a SIMATIC or for 2 000 mm DIN rail
non-Siemens PROFINET IO controller BusAdapter BA 2xRJ45 6ES7193-6AR00-0AA0
• PROFINET shared I-Device for 4 controllers BusAdapter BA 2xFC 6ES7193-6AF00-0AA0
for increased vibration and
• PROFINET IO IRT interface with integrated 3-port switch EMC loads
• Isochronous mode on PROFINET BusAdapter BA 2xSCRJ 6ES7193-6AP00-0AA0
• With multiple communication options: BusAdapter BA SCRJ/RJ45 6ES7193-6AP20-0AA0
Programming device/OP communication, PROFINET IO,
open IE communication (TCP, ISO-on-TCP and UDP), BusAdapter BA SCRJ/FC 6ES7193-6AP40-0AA0
web server and S7 communication (with loadable FBs) Equipment labeling plate 6ES7193-6LF30-0AW0
• OPC UA Server and Client (Data Access) as runtime option 10 sheets of 16 labels
for easy connection of the SIMATIC ET 200SP to non-Siemens Labeling strips
devices/systems
500 labeling strips on roll, light gray, 6ES7193-6LR10-0AA0
• Optional PROFIBUS master for 125 PROFIBUS DP slaves for inscription with thermal transfer
(with CM DP module 6ES7545-5DA00-0AB0) roll printer
• Configuration control (option handling) 500 labeling strips on roll, yellow, 6ES7193-6LR10-0AG0
• Integrated Motion Control functionalities for controlling for inscription with thermal transfer
roll printer
speed-controlled and positioning axes, support for external
encoders 1 000 labeling strips DIN A4, light 6ES7193-6LA10-0AA0
gray, card, for inscription with laser
Note printer
SIMATIC Memory Card required for operation of the CPU. 1 000 labeling strips DIN A4, yellow, 6ES7193-6LA10-0AG0
card, for inscription with laser
The BusAdapter is not included in the scope of supply and must printer
be ordered separately. IE FC RJ45 plugs
RJ45 plug connector for
Industrial Ethernet with a rugged
metal enclosure and integrated
insulation displacement contacts
for connecting Industrial Ethernet
FC installation cables
IE FC RJ45 plug 90
90° cable outlet
1 unit 6GK1901-1BB20-2AA0
10 units 6GK1901-1BB20-2AB0
50 units 6GK1901-1BB20-2AE0
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1510SP F-1 PN
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1510SP F-1 PN
■ Technical specifications
Article number 6ES7510-1SJ01-0AB0 Article number 6ES7510-1SJ01-0AB0
CPU1510SP F-1 PN, CPU1510SP F-1 PN,
150KB Prog./750KB Data 150KB Prog./750KB Data
General information 1. Interface
Product type designation CPU 1510SP F-1 PN Interface types
Engineering with • RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V13 SP1 Update 4 via BusAdapter BA 2x RJ45
integrated from version (FW V1.8) or higher • Number of ports 3; 1. integr. + 2. via BusAdapter
Supply voltage • integrated switch Yes
Type of supply voltage 24 V DC • BusAdapter (PROFINET) Yes; compatible BusAdapters:
Memory BA 2x RJ45, BA 2x FC, BA 2x M12
Work memory Protocols
• integrated (for program) 150 kbyte • IP protocol Yes; IPv4
• integrated (for data) 750 kbyte • PROFINET IO Controller Yes
Load memory • PROFINET IO Device Yes
• Plug-in (SIMATIC Memory Card), 32 Gbyte • SIMATIC communication Yes
max. • Open IE communication Yes; Optionally also encrypted
CPU processing times • Web server Yes
7 for bit operations, typ.
for word operations, typ.
72 ns
86 ns
• Media redundancy Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0
for fixed point arithmetic, typ. 115 ns PROFINET IO Controller
for floating point arithmetic, typ. 461 ns Services
Counters, timers and their - PG/OP communication Yes
retentivity - Isochronous mode Yes
S7 counter - Direct data exchange Yes; Requirement: IRT and
• Number 2 048 isochronous mode (MRPD optional)
IEC counter - IRT Yes
• Number Any - PROFIenergy Yes; per user program
(only limited by the main memory) - Prioritized startup Yes; Max. 32 PROFINET devices
S7 times - Number of connectable 64; In total, up to 256 distributed
• Number 2 048 IO Devices, max. I/O devices can be connected via
AS-i, PROFIBUS or PROFINET
IEC timer
- Of which IO devices with IRT, max. 64
• Number Any
(only limited by the main memory) - Number of connectable 64
IO Devices for RT, max.
Data areas and their retentivity
- of which in line, max. 64
Flag
- Number of IO Devices that can 8; in total across all interfaces
• Size, max. 16 kbyte be simultaneously activated/
Address area deactivated, max.
I/O address area - Number of IO Devices per tool, 8
max.
• Inputs 32 kbyte; All inputs are in the
process image - Updating times The minimum value of the
update time also depends on
• Outputs 32 kbyte; All outputs are in the communication share set for
process image PROFINET IO, on the number of
Address space per module IO devices, and on the quantity of
configured user data
• Address space per module, max. 288 byte; For input and output data
respectively PROFINET IO Device
Address space per station Services
• Address space per station, max. 2 560 byte; for central inputs and - PG/OP communication Yes
outputs; depending on configuration; - Isochronous mode No
2 048 bytes for ET 200SP modules +
512 bytes for ET 200AL modules - IRT Yes
Time of day - PROFIenergy Yes; per user program
Clock - Shared device Yes
• Type Hardware clock - Number of IO Controllers with 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program
- Asset management record Yes; per user program
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1510SP F-1 PN
■ Technical specifications
Article number 6ES7510-1SJ01-0AB0 Article number 6ES7510-1SJ01-0AB0
CPU1510SP F-1 PN, CPU1510SP F-1 PN,
150KB Prog./750KB Data 150KB Prog./750KB Data
2. Interface Standards, approvals, certificates
Interface types Highest safety class achievable in
• RS 485 Yes; Via CM DP module safety mode
• Number of ports 1 Probability of failure
(for service life of 20 years and
Protocols repair time of 100 hours)
• PROFIBUS DP master Yes - Low demand mode: < 2.00E-05
• PROFIBUS DP slave Yes PFDavg in accordance with SIL3
• SIMATIC communication Yes - High demand/continuous mode: < 1.00E-09
PFH in accordance with SIL3
PROFIBUS DP master
Ambient conditions
• Number of DP slaves, max. 125; In total, up to 256 distributed
I/O devices can be connected via Ambient temperature
AS-i, PROFIBUS or PROFINET during operation
Protocols • horizontal installation, min. -25 °C; No condensation
Number of connections • horizontal installation, max. 60 °C
• Number of connections, max. 96; via integrated interfaces of the • vertical installation, min. -25 °C; No condensation
Redundancy mode
CPU and connected CPs / CMs • vertical installation, max.
Altitude during operation
50 °C
7
Media redundancy relating to sea level
- Media redundancy Yes; only via BusAdapter • Installation altitude above sea level, 5 000 m; Restrictions for installation
max. altitudes > 2 000 m, see manual
- MRP Yes; MRP Automanager according
to IEC 62439-2 Edition 2.0, Configuration
MRP Manager; MRP Client Programming
- MRP interconnection, supported Yes; as MRP ring node according to Programming language
IEC 62439-2 Edition 3.0
- LAD Yes; incl. failsafe
- MRPD Yes; Requirement: IRT
- FBD Yes; incl. failsafe
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for
MRPD - STL Yes
- Number of stations in the ring, 50 - SCL Yes
max. - GRAPH Yes
SIMATIC communication Know-how protection
• S7 routing Yes • User program protection/ Yes
OPC UA password protection
• OPC UA Client Yes • Copy protection Yes
• OPC UA Server Yes; Data access • Block protection Yes
(read, write, subscribe), method call, Access protection
custom address space • protection of confidential Yes
• Alarms and Conditions Yes configuration data
Supported technology objects • Protection level: Write protection Yes
Motion Control Yes; Note: The number of technology • Protection level: Yes
objects affects the cycle time of the Read/write protection
PLC program; selection guide via the • Protection level: Yes
TIA Selection Tool Write protection for Failsafe
• Number of available Motion Control 800 • Protection level: Yes
resources for technology objects Complete protection
• Required Motion Control resources Dimensions
- per speed-controlled axis 40 Width 100 mm
- per positioning axis 80 Height 117 mm
- per synchronous axis 160 Depth 75 mm
- per external encoder 80 Weights
- per output cam 20 Weight, approx. 310 g
- per cam track 160
- per probe 40
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1512SP F-1 PN
• For applications with medium requirements in terms of • Length 483 mm for 19" cabinets 6ES5710-8MA11
program scope and processing speed, for distributed • Length 530 mm 6ES5710-8MA21
configurations via PROFINET IO or PROFIBUS DP. for 600 mm cabinets
• Increase in availability of systems and machines • Length 830 mm 6ES5710-8MA31
for 900 mm cabinets
• Supports PROFIsafe in centralized and distributed • Length 2 m 6ES5710-8MA41
configuration
PE connection element 6ES7590-5AA00-0AA0
• PROFINET IO controller for up to 128 IO devices for 2 000 mm DIN rail
• PROFINET I-Device for connecting the CPU BusAdapter BA 2xRJ45 6ES7193-6AR00-0AA0
as an intelligent PROFINET device with a SIMATIC or BusAdapter BA 2xFC 6ES7193-6AF00-0AA0
non-Siemens PROFINET IO controller for increased vibration and
• PROFINET shared I-Device for 4 controllers EMC loads
• PROFINET IO IRT interface with integrated 3-port switch BusAdapter BA 2xSCRJ 6ES7193-6AP00-0AA0
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1512SP F-1 PN
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1512SP F-1 PN
■ Technical specifications
Article number 6ES7512-1SK01-0AB0 Article number 6ES7512-1SK01-0AB0
CPU 1512SP F-1 PN, CPU 1512SP F-1 PN,
300KB Prog./1MB Data 300KB Prog./1MB Data
General information 1. Interface
Product type designation CPU 1512SP F-1 PN Interface types
Engineering with • RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V13 SP1 Update 4 via BusAdapter BA 2x RJ45
integrated from version (FW V1.8) or higher • Number of ports 3; 1. integr. + 2. via BusAdapter
Supply voltage • integrated switch Yes
Type of supply voltage 24 V DC • BusAdapter (PROFINET) Yes; compatible BusAdapters:
Memory BA 2x RJ45, BA 2x FC, BA 2x M12
Work memory Protocols
• integrated (for program) 300 kbyte • IP protocol Yes; IPv4
• integrated (for data) 1 Mbyte • PROFINET IO Controller Yes
Load memory • PROFINET IO Device Yes
• Plug-in (SIMATIC Memory Card), 32 Gbyte • SIMATIC communication Yes
max. • Open IE communication Yes; Optionally also encrypted
CPU processing times • Web server Yes
7 for bit operations, typ.
for word operations, typ.
48 ns
58 ns
• Media redundancy Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0
for fixed point arithmetic, typ. 77 ns PROFINET IO Controller
for floating point arithmetic, typ. 307 ns Services
Counters, timers and their - PG/OP communication Yes
retentivity - Isochronous mode Yes
S7 counter - Direct data exchange Yes; Requirement: IRT and
• Number 2 048 isochronous mode (MRPD optional)
IEC counter - IRT Yes
• Number Any - PROFIenergy Yes; per user program
(only limited by the main memory) - Prioritized startup Yes; Max. 32 PROFINET devices
S7 times - Number of connectable 128; In total, up to 512 distributed I/O
• Number 2 048 IO Devices, max. devices can be connected via AS-i,
PROFIBUS or PROFINET
IEC timer
- Of which IO devices with IRT, max. 64
• Number Any
(only limited by the main memory) - Number of connectable 128
IO Devices for RT, max.
Data areas and their retentivity
- of which in line, max. 128
Flag
- Number of IO Devices that can 8; in total across all interfaces
• Size, max. 16 kbyte be simultaneously activated/
Address area deactivated, max.
I/O address area - Number of IO Devices per tool, 8
max.
• Inputs 32 kbyte; All inputs are in the
process image - Updating times The minimum value of the
update time also depends on
• Outputs 32 kbyte; All outputs are in the communication share set for
process image PROFINET IO, on the number of
Address space per module IO devices, and on the quantity of
configured user data
• Address space per module, max. 288 byte; For input and output data
respectively PROFINET IO Device
Address space per station Services
• Address space per station, max. 2 560 byte; for central inputs and - PG/OP communication Yes
outputs; depending on configuration; - Isochronous mode No
2 048 bytes for ET 200SP modules +
512 bytes for ET 200AL modules - IRT Yes
Time of day - PROFIenergy Yes; per user program
Clock - Shared device Yes
• Type Hardware clock - Number of IO Controllers with 4
shared device, max.
- activation/deactivation of I-devices Yes; per user program
- Asset management record Yes; per user program
Distributed Controllers
based on ET 200SP
Fail-safe CPUs
CPU 1512SP F-1 PN
■ Technical specifications
Article number 6ES7512-1SK01-0AB0 Article number 6ES7512-1SK01-0AB0
CPU 1512SP F-1 PN, CPU 1512SP F-1 PN,
300KB Prog./1MB Data 300KB Prog./1MB Data
2. Interface Standards, approvals, certificates
Interface types Highest safety class achievable in
• RS 485 Yes; Via CM DP module safety mode
• Number of ports 1 Probability of failure
(for service life of 20 years and
Protocols repair time of 100 hours)
• PROFIBUS DP master Yes - Low demand mode: < 2.00E-05
• PROFIBUS DP slave Yes PFDavg in accordance with SIL3
• SIMATIC communication Yes - High demand/continuous mode: < 1.00E-09
PFH in accordance with SIL3
PROFIBUS DP master
Ambient conditions
• Number of DP slaves, max. 125; In total, up to 512 distributed
I/O devices can be connected via Ambient temperature
AS-i, PROFIBUS or PROFINET during operation
Protocols • horizontal installation, min. -25 °C; No condensation
Number of connections • horizontal installation, max. 60 °C
• Number of connections, max. 128; via integrated interfaces of the • vertical installation, min. -25 °C; No condensation
Redundancy mode
CPU and connected CPs / CMs • vertical installation, max.
Altitude during operation
50 °C
7
Media redundancy relating to sea level
- Media redundancy Yes; only via BusAdapter • Installation altitude above sea level, 5 000 m; Restrictions for installation
max. altitudes > 2 000 m, see manual
- MRP Yes; MRP Automanager according
to IEC 62439-2 Edition 2.0, Configuration
MRP Manager; MRP Client Programming
- MRP interconnection, supported Yes; as MRP ring node according to Programming language
IEC 62439-2 Edition 3.0
- LAD Yes; incl. failsafe
- MRPD Yes; Requirement: IRT
- FBD Yes; incl. failsafe
- Switchover time on line break, typ. 200 ms; For MRP, bumpless for
MRPD - STL Yes
- Number of stations in the ring, 50 - SCL Yes
max. - GRAPH Yes
SIMATIC communication Know-how protection
• S7 routing Yes • User program protection/password Yes
OPC UA protection
• OPC UA Client Yes • Copy protection Yes
• OPC UA Server Yes; Data access • Block protection Yes
(read, write, subscribe), method call, Access protection
custom address space • protection of confidential Yes
Supported technology objects configuration data
Motion Control Yes; Note: The number of technology • Protection level: Write protection Yes
objects affects the cycle time of the • Protection level: Yes
PLC program; selection guide via the Read/write protection
TIA Selection Tool
• Protection level: Yes
• Number of available Motion Control 800 Write protection for Failsafe
resources for technology objects
• Protection level: Yes
• Required Motion Control resources Complete protection
- per speed-controlled axis 40 Dimensions
- per positioning axis 80 Width 100 mm
- per synchronous axis 160 Height 117 mm
- per external encoder 80 Depth 75 mm
- per output cam 20 Weights
- per cam track 160 Weight, approx. 310 g
- per probe 40
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Distributed Controllers
based on ET 200SP
SIPLUS fail-safe CPUs
SIPLUS CPU 1510SP F-1 PN
Distributed Controllers
based on ET 200SP
SIPLUS fail-safe CPUs
SIPLUS CPU 1510SP F-1 PN
■ Technical specifications
Article number 6AG1510-1SJ01-2AB0 Article number 6AG1510-1SJ01-2AB0
Based on 6ES7510-1SJ01-0AB0 Based on 6ES7510-1SJ01-0AB0
SIPLUS ET 200SP SIPLUS ET 200SP
CPU 1510SP F-1PN CPU 1510SP F-1PN
Ambient conditions Usage in industrial process
Ambient temperature technology
during operation - Against chemically active Yes; Class 3
• horizontal installation, min. -25 °C; = Tmin substances acc. to EN 60654-4 (excluding trichlorethylene)
• horizontal installation, max. 60 °C; = Tmax - Environmental conditions for Yes; Level GX group A/B
process, measuring and control (excluding trichlorethylene;
• vertical installation, min. -25 °C; = Tmin systems acc. to ANSI/ISA-71.04 harmful gas concentrations up to
• vertical installation, max. 50 °C; = Tmax the limits of EN 60721-3-3 class 3C4
permissible); level LC3 (salt spray)
Altitude during operation and level LB3 (oil)
relating to sea level
Remark
• Installation altitude above sea level, 5 000 m
max. - Note regarding classification * The supplied plug covers must
of environmental conditions remain in place over the unused
• Ambient air temperature- Restrictions for installation altitudes acc. to EN 60721, EN 60654-4 interfaces during operation!
barometric pressure-altitude > 2 000 m, see entry ID: 109763260 and ANSI/ISA-71.04
Relative humidity Conformal coating
7
• With condensation, 100 %; RH incl. condensation / frost • Coatings for printed circuit board Yes; Class 2 for high reliability
tested in accordance (no commissioning in bedewed assemblies acc. to EN 61086
with IEC 60068-2-38, max. state), horizontal installation
• Protection against fouling acc. to Yes; Type 1 protection
Resistance EN 60664-3
Coolants and lubricants • Military testing according to Yes; Discoloration of coating
- Resistant to commercially Yes; Incl. diesel and oil droplets in MIL-I-46058C, Amendment 7 possible during service life
available coolants and lubricants the air • Qualification and Performance of Yes; Conformal coating, Class A
Use in stationary industrial systems Electrical Insulating Compound for
Printed Board Assemblies
- to biologically active substances Yes; Class 3B2 mold, fungus and
according to IPC-CC-830A
according to EN 60721-3-3 dry rot spores (with the exception of
fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl.
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
- Against mechanical environmental Yes; Class 3M8 using the
conditions acc. to EN 60721-3-3 SIPLUS Mounting Kit ET 200SP
(6AG1193-6AA00-0AA0)
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal
according to EN 60721-3-6 spores (excluding fauna);
Class 6B3 on request
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
(severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
- Against mechanical environmental Yes; Class 6M4 using the
conditions acc. to EN 60721-3-6 SIPLUS Mounting Kit ET 200SP
(6AG1193-6AA00-0AA0)
Distributed Controllers
based on ET 200SP
SIPLUS fail-safe CPUs
SIPLUS CPU 1512SP F-1 PN
• PROFINET IO controller for up to 128 IO devices SIPLUS Mounting Kit ET 200SP 6AG1193-6AA00-0AA0
• PROFINET I-Device for connecting the CPU Mounting accessories for use with
as an intelligent PROFINET device with a SIMATIC or increased mechanical vibration and
shock loads. Not approved for
non-Siemens PROFINET I/O controller SIPLUS BusAdapter 2xBA RJ45
• PROFINET shared I-Device for 4 controllers Other accessories See SIMATIC ET 200SP,
• PROFINET IO IRT interface with integrated 3-port switch CPU 1512 F-1 PN,
page 7/18
• Isochronous mode on PROFINET
• With multiple communication options:
PG/OP communication, PROFINET IO,
open IE communication (TCP, ISO-on-TCP and UDP),
web server and S7 communication (with loadable FBs)
• Optional PROFIBUS master for 125 PROFIBUS DP slaves
(with CM DP module 6ES7545-5DA00-0AB0)
• Configuration control (option handling)
• Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes, support for external
encoders
Note
SIMATIC Memory Card required for operation of the CPU.
The BusAdapter is not included in the scope of supply and must
be ordered separately.
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
corresponding standard products. SIPLUS extreme-specific
information was added.
Distributed Controllers
based on ET 200SP
SIPLUS fail-safe CPUs
SIPLUS CPU 1512SP F-1 PN
■ Technical specifications
Article number 6AG1512-1SK01-2AB0 6AG1512-1SK01-7AB0
Based on 6ES7512-1SK01-0AB0 6ES7512-1SK01-0AB0
SIPLUS ET 200SP CPU 1512SP F-1PN SIPLUS ET 200SP CPU 1512SP F-1 PN
Ambient conditions
Ambient temperature
during operation
• horizontal installation, min. -25 °C; = Tmin -40 °C; = Tmin (incl. condensation/frost)
• horizontal installation, max. 60 °C; = Tmax 70 °C; = Tmax
• vertical installation, min. -25 °C; = Tmin -40 °C; = Tmin
• vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation
relating to sea level
• Installation altitude above sea level, 5 000 m 5 000 m
max.
• Ambient air temperature- Restrictions for installation altitudes > 2 000 m, Restrictions for installation altitudes > 2 000 m,
barometric pressure-altitude see entry ID: 109763260 see entry ID: 109763260
Relative humidity
• With condensation, 100 %; RH incl. condensation / frost (no commissioning 100 %; RH incl. condensation / frost (no commissioning
7
tested in accordance in bedewed state), horizontal installation in bedewed state), horizontal installation
with IEC 60068-2-38, max.
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
- Against mechanical environmental Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-3 (6AG1193-6AA00-0AA0)
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold and fungal spores (excluding fauna); Yes; Class 6B2 mold, fungal and dry rot spores
according to EN 60721-3-6 Class 6B3 on request (excluding fauna)
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust
according to EN 60721-3-6 (with the exception of oil droplets in the air); *
- Against mechanical environmental Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-6 (6AG1193-6AA00-0AA0)
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and level class 3C4 permissible); level LC3 (salt spray) and level
LB3 (oil) LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance Yes; Conformal coating, Class A Yes; Conformal coating, Class A
of Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Standard CPUs > CPU 1515SP PC2
■ Overview
ET 200SP Open Controller, CPU 1515SP PC2, combines
robustness and compact dimensions with the flexibility of
centralized or decentralized communication in the highest
industrial functionality. Furthermore, the CPU offers the entire
value added of the ET 200SP system, the S7-1500 controller
family and the TIA world together.
• Rugged, compact control system
• Combines the functions of an ET 200SP controller with those
of a PC-based platform
• Turnkey all-in-one controller
• High performance automation tasks with the use of
new generation Intel Quad Core processors
• Connects high-level language applications and processes
high data volumes with support from SIMATIC ODK 1500S
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Standard CPUs > CPU 1515SP PC2
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Standard CPUs > CPU 1515SP PC2
■ Technical specifications
Article number 6ES7677-2DB42-0GB0 Article number 6ES7677-2DB42-0GB0
CPU1515SP PC2 CPU1515SP PC2
Interfaces PROFINET IO Controller
Number of industrial Ethernet 2 Services
interfaces - Isochronous mode Yes
Number of RS 485 interfaces 1; Via CM DP module - shortest clock pulse 500 µs
Number of USB interfaces 4; 2x USB 2.0, - IRT Yes
2x USB 3.0 on front side
- PROFIenergy Yes
Number of SD card slots 1
- Prioritized startup Yes; max. 32 PROFINET devices;
Video interfaces if you want to use the "Prioritized
• Graphics interface 1x DisplayPort startup" functionality in STEP 7 for
1. Interface the PROFINET interface of the CPU,
the CPU and the device must be
automatic detection of Yes separated by means of a switch
transmission rate (e.g. SCALANCE X205)
Autonegotiation Yes - Number of connectable 128
Autocrossing Yes IO Devices, max.
Number of connections 88 - Of which IO devices with IRT, max. 64
Interface types - of which in line, max. 64
7 • RJ 45 (Ethernet)
- Transmission rate, max.
Yes; Via BusAdapter BA 2x RJ45
100 Mbit/s
- Number of connectable
IO Devices for RT, max.
128
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Standard CPUs > CPU 1515SP PC2
■ Technical specifications
Article number 6ES7677-2DB42-0GB0 Article number 6ES7677-2DB42-0GB0
CPU1515SP PC2 CPU1515SP PC2
3. Interface Ambient conditions
Interface type PROFIBUS with CM DP Ambient temperature
Number of connections via this 44 during operation
interface • min. -20 °C
Interface types • max. Up to 60 °C with max.
• RS 485 Yes 32 ET 200SP modules; up to 55 °C
with max. 64 ET 200SP modules
Protocols
• horizontal installation, min. -20 °C
• PROFIBUS DP master Yes
• horizontal installation, max. 60 °C
• PROFIBUS DP slave Yes
• vertical installation, min. -20 °C
• SIMATIC communication Yes
• vertical installation, max. 50 °C;
PROFIBUS DP master With max. 32 ET 200SP modules
• Number of DP slaves, max. 125 Operating systems
Services pre-installed operating system Windows 10 IoT Enterprise 2016
- Equidistance No LTSB, 64bit, MUI
- Isochronous mode No Configuration
Address area
- Inputs, max. 8 kbyte
Programming
Programming language 7
- Outputs, max. 8 kbyte - LAD Yes
Protocols - FBD Yes
Number of connections - STL Yes
• Number of connections, max. 88 - SCL Yes
Redundancy mode - CFC No
Media redundancy - GRAPH Yes
- MRP Yes Know-how protection
- MRPD Yes • User program protection/ Yes
password protection
- Switchover time on line break, typ. 200 ms
• Copy protection Yes
- Number of stations in the ring, 50
max. • Block protection Yes
SIMATIC communication Access protection
• S7 routing Yes • Protection level: Write protection Yes
OPC UA • Protection level: Yes
Read/write protection
• OPC UA Client Yes; From SW CPU 1505SP V2.6
• Protection level: Yes
• OPC UA Server Yes; Data access (read, write, Complete protection
subscribe), runtime license required
Open Development interfaces
Supported technology objects
• Size of ODK SO file, max. 5.8 Mbyte
Motion Control Yes
Peripherals/Options
• Number of available Motion Control 2 400
resources for technology objects SD card Optionally for additional mass
storage
• Required Motion Control resources
Dimensions
- per speed-controlled axis 40; per axis
Width 160 mm
- per positioning axis 80; per axis
Height 117 mm
- per synchronous axis 160; per axis
Depth 75 mm
- per external encoder 80; per external encoder
Weights
- per output cam 20; per cam
Weight, approx. 0.83 kg
- per cam track 160; per cam track
- per probe 40; per probe
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Fail-safe CPUs > CPU 1515SP PC2 F
■ Overview
ET 200SP Open Controller, CPU 1515SP PC2 F, combines
robustness and compact dimensions with the flexibility of
centralized or decentralized communication in the highest
industrial functionality. Furthermore, the CPU offers the entire
value added of the ET 200SP system, the S7-1500 controller
family and the TIA world together.
• Rugged, compact control system
• Combines the functions of an ET 200SP controller with those
of a PC-based platform
• Turnkey all-in-one controller
• Can be used up to safety class SIL3 (Safety Integrity Level)
according to IEC 61508 2nd Edition or PL e (Performance
Level) according to ISO 13849
• High performance automation tasks with the use of
new generation Intel Quad Core processors
• Connects high-level language applications and processes
high data volumes with support from SIMATIC ODK 1500S
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Fail-safe CPUs > CPU 1515SP PC2 F
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Fail-safe CPUs > CPU 1515SP PC2 F
■ Technical specifications
Article number 6ES7677-2SB42-0GB0 Article number 6ES7677-2SB42-0GB0
CPU1515SP PC2 F CPU1515SP PC2 F
Video interfaces 2. Interface
• Graphics interface 1x DisplayPort Interface type Integrated Ethernet interface
1. Interface automatic detection of transmission Yes
automatic detection of transmission Yes rate
rate Autonegotiation Yes
Autonegotiation Yes Autocrossing Yes
Autocrossing Yes Interface types
Number of connections 88 • RJ 45 (Ethernet) Yes; Integrated
Interface types - Transmission rate, max. 1 000 Mbit/s
• RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45 - Industrial Ethernet status LED No
- Transmission rate, max. 100 Mbit/s • Number of ports 1
- Industrial Ethernet status LED Yes 3. Interface
• Number of ports 2 Interface type PROFIBUS with CM DP
• integrated switch Yes Number of connections 44
• BusAdapter (PROFINET) Yes; Compatible BusAdapter: via this interface
7
BA 2x RJ45, BA 2x FC, Interface types
BA 2x SCRJ (from FS03, V2.2), • RS 485 Yes
BA SCRJ / RJ45 (from FS03, V3.1),
BA SCRJ / FC (from FS03, V3.1), Protocols
BA 2x LC (from FS03, V3.3), • PROFIBUS DP master Yes
BA LC / RJ45 (from FS03, V3.3),
BA LC / FC (from FS03, V3.3) • PROFIBUS DP slave Yes
Protocols • SIMATIC communication Yes
• PROFINET IO Controller Yes PROFIBUS DP master
• PROFINET IO Device Yes • Number of DP slaves, max. 125
• SIMATIC communication Yes Services
• Open IE communication Yes - Equidistance No
• Web server Yes - Isochronous mode No
PROFINET IO Controller Protocols
Services Number of connections
- Isochronous mode Yes • Number of connections, max. 88
- shortest clock pulse 500 µs Redundancy mode
- IRT Yes Media redundancy
- Prioritized startup Yes; Max. 32 PROFINET devices - MRP Yes
- Number of connectable 128 - MRPD Yes
IO Devices, max. - Switchover time on line break, typ. 200 ms
- Of which IO devices with IRT, max. 64 - Number of stations in the ring, 50
- of which in line, max. 64 max.
- Number of connectable 128 SIMATIC communication
IO Devices for RT, max. • S7 routing Yes
- of which in line, max. 128 OPC UA
- Number of IO Devices that can 8 • OPC UA Server Yes; Data access
be simultaneously activated/ (read, write, subscribe),
deactivated, max. runtime license required
- IO Devices changing Yes
during operation (partner ports),
supported
- Number of IO Devices per tool, 8
max.
- Updating times The minimum value of the
update time also depends on
communication share set for
PROFINET IO, on the number of
IO devices, and on the quantity of
configured user data
PROFINET IO Device
Services
- Isochronous mode No
- IRT Yes
- Prioritized startup Yes
- Shared device Yes
- Number of IO Controllers 4
with shared device, max.
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Fail-safe CPUs > CPU 1515SP PC2 F
■ Technical specifications
Article number 6ES7677-2SB42-0GB0 Article number 6ES7677-2SB42-0GB0
CPU1515SP PC2 F CPU1515SP PC2 F
Supported technology objects Operating systems
Motion Control Yes pre-installed operating system Windows 10 IoT Enterprise 2016
• Number of available Motion Control 2 400 LTSB, 64bit, MUI
resources for technology objects Configuration
• Required Motion Control resources Programming
- per speed-controlled axis 40; per axis Programming language
- per positioning axis 80; per axis - LAD Yes; incl. failsafe
- per synchronous axis 160; per axis - FBD Yes; incl. failsafe
- per external encoder 80; per external encoder - STL Yes
- per output cam 20; per cam - SCL Yes
- per cam track 160; per cam track - CFC No
- per probe 40; per probe - GRAPH Yes
Controller Know-how protection
• PID_Compact Yes; Universal PID controller with • User program protection/ Yes
integrated optimization password protection
7
• PID_3Step Yes; PID controller with integrated • Copy protection Yes
optimization for valves • Block protection Yes
• PID-Temp Yes; PID controller with integrated Access protection
optimization for temperature
• Protection level: Write protection Yes
Counting and measuring
• Protection level: Yes
• High-speed counter Yes Read/write protection
Standards, approvals, certificates • Protection level: Yes
Highest safety class achievable Complete protection
in safety mode Open Development interfaces
• Performance level according to PL e • Size of ODK SO file, max. 3.8 Mbyte
ISO 13849-1
Peripherals/Options
• SIL acc. to IEC 61508 SIL 3
SD card Optionally for additional mass
Probability of failure storage
(for service life of 20 years and
repair time of 100 hours) Dimensions
- Low demand mode: < 2.00E-05 Width 160 mm
PFDavg in accordance with SIL3 Height 117 mm
- High demand/continuous mode: < 1.00E-09 1/h Depth 75 mm
PFH in accordance with SIL3
Weights
Ambient conditions
Weight, approx. 0.83 kg
Ambient temperature
during operation
• min. -20 °C
• max. Up to 60 °C with max. 32 ET 200SP
modules and 3x 100 mA USB load;
up to 55 °C with max. 64 ET 200SP
modules and 2x max. 500 mA and
1x max. 100 mA USB load
• horizontal installation, min. -20 °C
• horizontal installation, max. 60 °C
• vertical installation, min. -20 °C
• vertical installation, max. 50 °C;
With max. 32 ET 200SP modules
and 3x 100 mA USB load
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 T
■ Overview
ET 200SP Open Controller CPU 1515SP PC2 T combines
robustness and compact dimensions with the flexibility of
centralized or decentralized communication in the highest
industrial functionality. Furthermore, the CPU offers the entire
value added of the ET 200SP system, the S7-1500 controller
family and the TIA world together.
• Rugged, compact control system
• Combines the functions of an ET 200SP controller with those
of a PC-based platform
• Turnkey all-in-one controller
• High performance automation tasks with the use of
new generation Intel Quad Core processors
• Connects high-level language applications and processes
high data volumes with support from SIMATIC ODK 1500S
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 T
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 T
■ Technical specifications
Article number 6ES7677-2VB42-0GB0 Article number 6ES7677-2VB42-0GB0
CPU1515SP PC2 T CPU1515SP PC2 T
Video interfaces PROFINET IO Device
• Graphics interface 1x DisplayPort Services
1. Interface - Isochronous mode No
automatic detection of transmission Yes - shortest clock pulse 500 µs
rate - IRT Yes
Autonegotiation Yes - PROFIenergy Yes
Autocrossing Yes - Prioritized startup Yes
Number of connections 88 - Shared device Yes
Interface types - Number of IO Controllers with 4
• RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45 shared device, max.
- Transmission rate, max. 100 Mbit/s - Asset management record Yes
- Industrial Ethernet status LED Yes 2. Interface
• Number of ports 2 Interface type Integrated Ethernet interface
• integrated switch Yes automatic detection of transmission Yes
• BusAdapter (PROFINET) Yes; Compatible BusAdapter: rate
7
BA 2x RJ45, BA 2x FC, Autonegotiation Yes
BA 2x SCRJ (from FS03, V2.2), Autocrossing Yes
BA SCRJ / RJ45 (from FS03, V3.1),
BA SCRJ / FC (from FS03, V3.1), Interface types
BA 2x LC (from FS03, V3.3), • RJ 45 (Ethernet) Yes; Integrated
BA LC / RJ45 (from FS03, V3.3),
BA LC / FC (from FS03, V3.3) - Transmission rate, max. 1 000 Mbit/s
Protocols - Industrial Ethernet status LED No
• PROFINET IO Controller Yes • Number of ports 1
• PROFINET IO Device Yes 3. Interface
• SIMATIC communication Yes Interface type PROFIBUS with CM DP
• Open IE communication Yes Number of connections 44
via this interface
• Web server Yes
Interface types
PROFINET IO Controller
• RS 485 Yes
Services
Protocols
- Isochronous mode Yes
• PROFIBUS DP master Yes
- shortest clock pulse 500 µs
• PROFIBUS DP slave Yes
- IRT Yes
• SIMATIC communication Yes
- PROFIenergy Yes
PROFIBUS DP master
- Prioritized startup Yes; max. 32 PROFINET devices;
if you want to use the "Prioritized • Number of DP slaves, max. 125
startup" functionality in STEP 7 for Services
the PROFINET interface of the CPU,
- Equidistance No
the CPU and the device must be
separated by means of a switch - Isochronous mode No
(e.g. SCALANCE X205) Address area
- Number of connectable 128 - Inputs, max. 8 kbyte
IO Devices, max.
- Outputs, max. 8 kbyte
- Of which IO devices with IRT, max. 64
Protocols
- of which in line, max. 64
Number of connections
- Number of connectable 128
IO Devices for RT, max. • Number of connections, max. 88
- of which in line, max. 128 Redundancy mode
- Number of IO Devices that can 8 Media redundancy
be simultaneously activated/ - Switchover time on line break, typ. 200 ms
deactivated, max.
- Number of stations in the ring, 50
- IO Devices changing during oper- Yes max.
ation (partner ports), supported
SIMATIC communication
- Number of IO Devices per tool, 8
max. • S7 routing Yes
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 T
■ Technical specifications
Article number 6ES7677-2VB42-0GB0 Article number 6ES7677-2VB42-0GB0
CPU1515SP PC2 T CPU1515SP PC2 T
Supported technology objects Operating systems
Motion Control Yes pre-installed operating system Windows 10 IoT Enterprise 2016
• Number of available Motion Control 2 400 LTSB, 64bit, MUI
resources for technology objects Configuration
• Required Motion Control resources Programming
- per speed-controlled axis 40; per axis Programming language
- per positioning axis 80; per axis - LAD Yes
- per synchronous axis 160; per axis - FBD Yes
- per external encoder 80; per external encoder - STL Yes
- per output cam 20; per cam - SCL Yes
- per cam track 160; per cam track - CFC No
- per probe 40; per probe - GRAPH Yes
• Number of available 120 Know-how protection
Extended Motion Control resources • User program protection/ Yes
for technology objects password protection
• Required Extended Motion Control
7
• Copy protection Yes
resources
• Block protection Yes
- per cam 2
(1 000 points and 50 segments) Access protection
- for each set of kinematics 30 • Protection level: Write protection Yes
- Per leading axis proxy 3 • Protection level: Yes
Read/write protection
Controller
• Protection level: Yes
• PID_Compact Yes; Universal PID controller with Complete protection
integrated optimization
Open Development interfaces
• PID_3Step Yes; PID controller with integrated
optimization for valves • Size of ODK SO file, max. 5.8 Mbyte
• PID-Temp Yes; PID controller with integrated Peripherals/Options
optimization for temperature SD card Optionally for additional mass
Counting and measuring storage
• High-speed counter Yes Dimensions
Ambient conditions Width 160 mm
Ambient temperature Height 117 mm
during operation Depth 75 mm
• min. -20 °C Weights
• max. Up to 60 °C with max. 32 ET 200SP Weight, approx. 0.83 kg
modules; up to 55 °C with
max. 64 ET 200SP modules
• horizontal installation, min. -20 °C
• horizontal installation, max. 60 °C
• vertical installation, min. -20 °C
• vertical installation, max. 50 °C;
With max. 32 ET 200SP modules
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 TF
■ Overview
ET 200SP Open Controller, CPU 1515SP PC2 TF, combines
robustness and compact dimensions with the flexibility of
centralized or decentralized communication in the highest
industrial functionality. Furthermore, the CPU offers the entire
value added of the ET 200SP system, the S7-1500 controller
family and the TIA world together.
• Rugged, compact control system
• Combines the functions of a ET 200SP controller with those of
a PC-based platform
• Turnkey all-in-one controller
• Can be used up to safety class SIL3 (Safety Integrity Level)
according to IEC 61508 2nd Edition or PL e (Performance
Level) according to ISO 13849
• High performance automation tasks with the use of
new generation Intel Quad Core processors
• Connects high-level language applications and processes
high data volumes with support from SIMATIC ODK 1500S
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 TF
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 TF
■ Technical specifications
Article number 6ES7677-2WB42-0GB0 Article number 6ES7677-2WB42-0GB0
CPU1515SP PC2 TF CPU1515SP PC2 TF
Video interfaces PROFINET IO Device
• Graphics interface 1x DisplayPort Services
1. Interface - Isochronous mode No
automatic detection of transmission Yes - shortest clock pulse 500 µs
rate - IRT Yes
Autonegotiation Yes - PROFIenergy Yes
Autocrossing Yes - Prioritized startup Yes
Number of connections 88 - Shared device Yes
Interface types - Number of IO Controllers with 4
• RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45 shared device, max.
- Transmission rate, max. 100 Mbit/s - Asset management record Yes
- Industrial Ethernet status LED Yes 2. Interface
• Number of ports 2 Interface type Integrated Ethernet interface
• integrated switch Yes automatic detection of transmission Yes
• BusAdapter (PROFINET) Yes; Compatible BusAdapter: rate
7
BA 2x RJ45, BA 2x FC, Autonegotiation Yes
BA 2x SCRJ (from FS03, V2.2), Autocrossing Yes
BA SCRJ / RJ45 (from FS03, V3.1),
BA SCRJ / FC (from FS03, V3.1), Interface types
BA 2x LC (from FS03, V3.3), • RJ 45 (Ethernet) Yes; Integrated
BA LC / RJ45 (from FS03, V3.3),
BA LC / FC (from FS03, V3.3) - Transmission rate, max. 1 000 Mbit/s
Protocols - Industrial Ethernet status LED No
• PROFINET IO Controller Yes • Number of ports 1
• PROFINET IO Device Yes 3. Interface
• SIMATIC communication Yes Interface type PROFIBUS with CM DP
• Open IE communication Yes Number of connections 44
via this interface
• Web server Yes
Interface types
PROFINET IO Controller
• RS 485 Yes
Services
Protocols
- Isochronous mode Yes
• PROFIBUS DP master Yes
- shortest clock pulse 500 µs
• PROFIBUS DP slave Yes
- IRT Yes
• SIMATIC communication Yes
- PROFIenergy Yes
PROFIBUS DP master
- Prioritized startup Yes; max. 32 PROFINET devices;
if you want to use the "Prioritized • Number of DP slaves, max. 125
startup" functionality in STEP 7 for Services
the PROFINET interface of the CPU,
- Equidistance No
the CPU and the device must be
separated by means of a switch - Isochronous mode No
(e.g. SCALANCE X205) Address area
- Number of connectable 128 - Inputs, max. 8 kbyte
IO Devices, max.
- Outputs, max. 8 kbyte
- Of which IO devices with IRT, max. 64
Protocols
- of which in line, max. 64
Number of connections
- Number of connectable 128
IO Devices for RT, max. • Number of connections, max. 88
- of which in line, max. 128 Redundancy mode
- Number of IO Devices that can 8 Media redundancy
be simultaneously activated/ - Switchover time on line break, typ. 200 ms
deactivated, max.
- Number of stations in the ring, 50
- IO Devices changing during Yes max.
operation (partner ports),
supported SIMATIC communication
Distributed Controllers
based on ET 200SP
ET 200SP Open Controllers
Technology CPUs > CPU 1515SP PC2 TF
■ Technical specifications
Article number 6ES7677-2WB42-0GB0 Article number 6ES7677-2WB42-0GB0
CPU1515SP PC2 TF CPU1515SP PC2 TF
Supported technology objects Operating systems
Motion Control Yes pre-installed operating system Windows 10 IoT Enterprise 2016
• Number of available Motion Control 2 400 LTSB, 64bit, MUI
resources for technology objects Configuration
• Required Motion Control resources Programming
- per speed-controlled axis 40; per axis Programming language
- per positioning axis 80; per axis - LAD Yes; incl. failsafe
- per synchronous axis 160; per axis - FBD Yes; incl. failsafe
- per external encoder 80; per external encoder - STL Yes
- per output cam 20; per cam - SCL Yes
- per cam track 160; per cam track - CFC No
- per probe 40; per probe - GRAPH Yes
• Number of available 120 Know-how protection
Extended Motion Control resources • User program protection/ Yes
for technology objects password protection
• Required Extended Motion Control
7
• Copy protection Yes
resources
• Block protection Yes
- per cam 2
(1 000 points and 50 segments) Access protection
- for each set of kinematics 30 • Protection level: Write protection Yes
- Per leading axis proxy 3 • Protection level: Yes
Read/write protection
Controller
• Protection level: Yes
• PID_Compact Yes; Universal PID controller with Complete protection
integrated optimization
Open Development interfaces
• PID_3Step Yes; PID controller with integrated
optimization for valves • Size of ODK SO file, max. 5.8 Mbyte
• PID-Temp Yes; PID controller with integrated Peripherals/Options
optimization for temperature SD card Optionally for additional mass
Counting and measuring storage
• High-speed counter Yes Dimensions
Standards, approvals, certificates Width 160 mm
Highest safety class achievable Height 117 mm
in safety mode Depth 75 mm
• Performance level according to PL e Weights
ISO 13849-1
Weight, approx. 0.83 kg
• SIL acc. to IEC 61508 SIL 3
Probability of failure
(for service life of 20 years and
repair time of 100 hours)
- Low demand mode: < 2.00E-05
PFDavg in accordance with SIL3
- High demand/continuous mode: < 1.00E-09 1/h
PFH in accordance with SIL3
Ambient conditions
Ambient temperature
during operation
• min. -20 °C
• max. Up to 60 °C with max. 32 ET 200SP
modules; up to 55 °C
with max. 64 ET 200SP modules
• horizontal installation, min. -20 °C
• horizontal installation, max. 60 °C
• vertical installation, min. -20 °C
• vertical installation, max. 50 °C;
With max. 32 ET 200SP modules
Distributed Controllers
based on ET 200SP
SIPLUS ET 200SP Open Controllers
SIPLUS standard CPUs > SIPLUS CPU 1515SP PC2
SIPLUS ET 200SP
Open Controller
CPU 1515SP PC2
(Extended temperature range
and exposure to environmental
substances)
SIPLUS ET 200SP CPU with
Windows 10 IoT Enterprise 64-bit
and pre-installed SIMATIC S7-1500
Software Controller; 8 GB RAM,
30 GB CFast card
Type of delivery:
English, German, Chinese, Italian,
French, Spanish
• SIPLUS CPU 1515SP PC2 6AG1677-2DB42-2GB0
Spare part, without CFast card
• SIPLUS CPU 1515SP PC2 6AG1677-2DB40-2AA0
Accessories
BusAdapter BA 2xRJ45 6AG1193-6AR00-7AA0
Distributed Controllers
based on ET 200SP
SIPLUS ET 200SP Open Controllers
SIPLUS standard CPUs > SIPLUS CPU 1515SP PC2
■ Technical specifications
Article number 6AG1677-2DB42-2GB0 6AG1677-2DB40-2AA0
Based on 6ES7677-2DB42-0GB0 6ES7677-2DB40-0AA0
SIPLUS ET 200SP CPU1515SP PC2 SIPLUS ET 200SP CPU1515SP PC2
Ambient conditions
Ambient temperature
during operation
• min. -40 °C; = Tmin -40 °C; = Tmin
• max. Up to 60 °C with max. 32 ET 200SP modules; Up to 60 °C with max. 32 ET 200SP modules;
up to 55 °C with max. 64 ET 200SP modules up to 55 °C with max. 64 ET 200SP modules
• horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost)
• horizontal installation, max. 60 °C; = Tmax 60 °C; = Tmax
• vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin
• vertical installation, max. 50 °C; = Tmax; with max. 32 ET 200SP modules 50 °C; = Tmax; with max. 32 ET 200SP modules
Altitude during operation
relating to sea level
• Installation altitude above sea level, 2 000 m 2 000 m
max.
• Ambient air temperature- Tmin ... Tmax at 1 140 hPa ... 795 hPa Tmin ... Tmax at 1 140 hPa ... 795 hPa
7
barometric pressure-altitude (-1 000 m ... +2 000 m) (-1 000 m ... +2 000 m)
Relative humidity
• With condensation, 100 %; RH incl. condensation / frost 100 %; RH incl. condensation / frost
tested in accordance (no commissioning in bedewed state), (no commissioning in bedewed state),
with IEC 60068-2-38, max. horizontal installation horizontal installation
Resistance
Coolants and lubricants
- Resistant to commercially Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
available coolants and lubricants
Use in stationary industrial systems
- to biologically active substances Yes; Class 3B2 mold, fungus and dry rot spores Yes; Class 3B2 mold, fungus and dry rot spores
according to EN 60721-3-3 (with the exception of fauna); Class 3B3 on request (with the exception of fauna); Class 3B3 on request
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-3 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
- Against mechanical environmental Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-3 (6AG1193-6AA00-0AA0) (6AG1193-6AA00-0AA0)
Use on ships/at sea
- to biologically active substances Yes; Class 6B2 mold, fungal and dry rot spores Yes; Class 6B2 mold, fungal and dry rot spores
according to EN 60721-3-6 (excluding fauna) (excluding fauna)
- to chemically active substances Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
according to EN 60721-3-6 EN 60068-2-52 (severity degree 3); * EN 60068-2-52 (severity degree 3); *
- to mechanically active substances Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
according to EN 60721-3-6
- Against mechanical environmental Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP
conditions acc. to EN 60721-3-6 (6AG1193-6AA00-0AA0) (6AG1193-6AA00-0AA0)
Usage in industrial process
technology
- Against chemically active Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
substances acc. to EN 60654-4
- Environmental conditions for Yes; Level GX group A/B (excluding trichlorethylene; Yes; Level GX group A/B (excluding trichlorethylene;
process, measuring and control harmful gas concentrations up to the limits of EN 60721-3-3 harmful gas concentrations up to the limits of EN 60721-3-3
systems acc. to ANSI/ISA-71.04 class 3C4 permissible); level LC3 (salt spray) and class 3C4 permissible); level LC3 (salt spray) and
level LB3 (oil) level LB3 (oil)
Remark
- Note regarding classification * The supplied plug covers must remain in place over the * The supplied plug covers must remain in place over the
of environmental conditions unused interfaces during operation! unused interfaces during operation!
acc. to EN 60721, EN 60654-4
and ANSI/ISA-71.04
Conformal coating
• Coatings for printed circuit board Yes; Class 2 for high reliability Yes; Class 2 for high reliability
assemblies acc. to EN 61086
• Protection against fouling acc. to Yes; Type 1 protection Yes; Type 1 protection
EN 60664-3
• Military testing according to Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
MIL-I-46058C, Amendment 7
• Qualification and Performance Yes; Conformal coating, Class A Yes; Conformal coating, Class A
of Electrical Insulating Compound
for Printed Board Assemblies
according to IPC-CC-830A
Distributed Controllers
based on ET 200SP
SIPLUS ET 200SP Open Controllers
SIPLUS fail-safe CPUs > SIPLUS CPU 1515SP PC2 F
SIPLUS ET 200SP
Open Controller
CPU 1515SP PC2 F
(Extended temperature range
and exposure to environmental
substances)
Fail-safe ET 200SP CPU with
Windows 10 IoT Enterprise 64-bit
and pre-installed SIMATIC S7-1500
Failsafe Software Controller
(with WinCC RT Advanced option);
8 GB RAM, 30 GB CFast card;
Type of delivery:
English, German, Chinese, Italian,
French, Spanish
• SIPLUS CPU 1515SP PC2 F 6AG1677-2SB42-2GB0
Accessories
BusAdapter BA 2xRJ45 6AG1193-6AR00-7AA0
(Extended temperature range
and exposure to environmental
• High performance automation tasks with the use of SIPLUS Mounting Kit ET 200SP 6AG1193-6AA00-0AA0
new generation Intel Quad Core processors Mounting accessories for use with
increased mechanical vibration and
• Connects high-level language applications and processes shock loads. Not approved for
high data volumes with support from SIMATIC ODK 1500S SIPLUS BusAdapter BA 2xRJ45
Note Other accessories See SIMATIC CPU 1515SP PC2 F,
page 7/30
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.
Distributed Controllers
based on ET 200SP
SIPLUS ET 200SP Open Controllers
SIPLUS fail-safe CPUs > SIPLUS CPU 1515SP PC2 F
■ Technical specifications
Article number 6AG1677-2SB42-2GB0 Article number 6AG1677-2SB42-2GB0
Based on 6ES7677-2SB42-0GB0 Based on 6ES7677-2SB42-0GB0
SIPLUS ET 200SP SIPLUS ET 200SP
CPU1515SP PC2 F CPU1515SP PC2 F
Ambient conditions Use on ships/at sea
Ambient temperature - to biologically active substances Yes; Class 6B2 mold, fungal and
during operation according to EN 60721-3-6 dry rot spores (excluding fauna)
• min. -40 °C; = Tmin - to chemically active substances Yes; Class 6C3 (RH < 75 %) incl.
• max. Up to 60 °C with max. 32 ET 200SP according to EN 60721-3-6 salt spray acc. to EN 60068-2-52
modules; up to 55 °C with max. (severity degree 3); *
64 ET 200SP modules - to mechanically active substances Yes; Class 6S3 incl. sand, dust; *
• horizontal installation, min. -40 °C; = Tmin according to EN 60721-3-6
(incl. condensation/frost) - Against mechanical environmental Yes; Class 6M4 using the
• horizontal installation, max. 60 °C; = Tmax conditions acc. to EN 60721-3-6 SIPLUS Mounting Kit ET 200SP
(6AG1193-6AA00-0AA0)
• vertical installation, min. -40 °C; = Tmin
Usage in industrial process
• vertical installation, max. 50 °C; = Tmax; technology
with max. 32 ET 200SP modules
- Against chemically active Yes; Class 3
Altitude during operation substances acc. to EN 60654-4 (excluding trichlorethylene)
relating to sea level
- Environmental conditions for Yes; Level GX group A/B
• Installation altitude above sea level, 2 000 m
max.
process, measuring and control
systems acc. to ANSI/ISA-71.04
(excluding trichlorethylene;
harmful gas concentrations up to
7
• Ambient air temperature- Tmin ... Tmax at the limits of EN 60721-3-3 class 3C4
barometric pressure-altitude 1 140 hPa ... 795 hPa permissible); level LC3 (salt spray)
(-1 000 m ... +2 000 m) and level LB3 (oil)
Relative humidity Remark
• With condensation, 100 %; RH incl. condensation / frost - Note regarding classification * The supplied plug covers must
tested in accordance (no commissioning in bedewed of environmental conditions remain in place over the unused
with IEC 60068-2-38, max. state), horizontal installation acc. to EN 60721, EN 60654-4 interfaces during operation!
and ANSI/ISA-71.04
Resistance
Conformal coating
Coolants and lubricants
• Coatings for printed circuit board Yes; Class 2 for high reliability
- Resistant to commercially Yes; Incl. diesel and oil droplets in assemblies acc. to EN 61086
available coolants and lubricants the air
• Protection against fouling acc. to Yes; Type 1 protection
Use in stationary industrial systems EN 60664-3
- to biologically active substances Yes; Class 3B2 mold, fungus and dry • Military testing according to Yes; Discoloration of coating
according to EN 60721-3-3 rot spores (with the exception of MIL-I-46058C, Amendment 7 possible during service life
fauna); Class 3B3 on request
• Qualification and Performance Yes; Conformal coating, Class A
- to chemically active substances Yes; Class 3C4 (RH < 75 %) incl. of Electrical Insulating Compound
according to EN 60721-3-3 salt spray acc. to EN 60068-2-52 for Printed Board Assemblies
(severity degree 3); * according to IPC-CC-830A
- to mechanically active substances Yes; Class 3S4 incl. sand, dust, *
according to EN 60721-3-3
- Against mechanical environmental Yes; Class 3M8 using the
conditions acc. to EN 60721-3-3 SIPLUS Mounting Kit ET 200SP
(6AG1193-6AA00-0AA0)
Distributed Controllers
based on ET 200Pro
Standard CPUs
IM 154-8 PN/DP CPU
■ Overview
• CPU with PLC functionality equivalent to S7-315-2 PN/DP
provides distributed intelligence for preprocessing
• Interface module for exchanging pre-processed I/O data
between the ET 200pro and a higher-level master/IO controller
via PROFIBUS DP/PROFINET IO
• PROFINET IO controller for operating distributed I/O
on PROFINET
• Component-based Automation (CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP
in Component-based Automation (CBA)
• PROFINET interface with 3-port switch
• Isochronous mode on PROFIBUS or PROFINET
• Integrated web server with the option of creating user-defined
web pages
• CPU with PLC functionality equivalent to S7-315-2 PN/DP
provides distributed intelligence for preprocessing
• Fast, simple and end-to-end programming of a system
7 with modular programs via STEP 7
• Fail-safe IM 154-8F PN/DP CPU PROFIsafe available
Note
SIMATIC Micro Memory Card required for operation of CPU.
Distributed Controllers
based on ET 200Pro
Standard CPUs
IM 154-8 PN/DP CPU
Distributed Controllers
based on ET 200Pro
Standard CPUs
IM 154-8 PN/DP CPU
■ Technical specifications
Article number 6ES7154-8AB01-0AB0 Article number 6ES7154-8AB01-0AB0
ET 200pro: ET 200pro:
IM 154-8 PN/DP CPU, 384KB IM 154-8 PN/DP CPU, 384KB
General information Data areas and their retentivity
Product function Flag
• Isochronous mode Yes; Via PROFIBUS DP or • Size, max. 2 048 byte
PROFINET interface Address area
Supply voltage I/O address area
Rated value (DC) 24 V • Inputs 2 048 byte
Power loss • Outputs 2 048 byte
Power loss, typ. 8.5 W Process image
Memory • Inputs, adjustable 2 048 byte
Work memory • Outputs, adjustable 2 048 byte
• integrated 384 kbyte Time of day
• expandable No Clock
Load memory • Hardware clock (real-time) Yes
• Plug-in (MMC), max. 8 Mbyte Operating hours counter
CPU processing times • Number 1
for bit operations, typ. 0.05 µs Interfaces
for word operations, typ. 0.09 µs Interfaces/bus type 1x MPI/PROFIBUS DP,
for fixed point arithmetic, typ. 0.12 µs 1x PROFINET (3 ports)
for floating point arithmetic, typ. 0.45 µs 1. Interface
Counters, timers and their Interface type Integrated RS 485 interface
retentivity Interface types
S7 counter • RS 485 Yes
• Number 256 Protocols
IEC counter • MPI Yes
• present Yes • PROFIBUS DP master Yes
S7 times • PROFIBUS DP slave Yes
• Number 256 • Point-to-point connection No
IEC timer PROFIBUS DP master
• present Yes • Number of DP slaves, max. 124
Distributed Controllers
based on ET 200Pro
Standard CPUs
IM 154-8 PN/DP CPU
■ Technical specifications
Article number 6ES7154-8AB01-0AB0 Article number 6ES7154-8AB01-0AB0
ET 200pro: ET 200pro:
IM 154-8 PN/DP CPU, 384KB IM 154-8 PN/DP CPU, 384KB
2. Interface Communication functions
Interface types PG/OP communication Yes
• Number of ports 3 Global data communication
Protocols • supported Yes
• MPI No S7 basic communication
• PROFINET IO Controller Yes; Also simultaneously • supported Yes
with IO-Device functionality S7 communication
• PROFINET IO Device Yes; Also simultaneously • supported Yes
with IO Controller functionality
Number of connections
• PROFINET CBA Yes
• overall 16
• PROFIBUS DP master No
Configuration
• PROFIBUS DP slave No
Programming
PROFINET IO Controller
Programming language
Services
- LAD Yes
- Number of connectable 128
IO Devices, max.
- Of which IO devices with IRT, max. 64
- FBD
- STL
Yes
Yes 7
- Number of IO Devices with IRT and 128 - SCL Yes
the option "high flexibility" - CFC Yes
- Number of connectable 128 - GRAPH Yes
IO Devices for RT, max.
- HiGraph® Yes
Protocols
Know-how protection
SIMATIC communication
• User program protection/ Yes
• S7 routing Yes password protection
Open IE communication • Block encryption Yes; With S7 block Privacy
• TCP/IP Yes; via integrated Dimensions
PROFINET interface and
loadable FBs Width 135 mm
- Number of connections, max. 8 Height 130 mm
• ISO-on-TCP (RFC1006) Yes Depth 65 mm; 60 mm without cover for
RJ45 socket; 65 mm with cover for
- Number of connections, max. 8 RJ45 socket
• UDP Yes Weights
- Number of connections, max. 8 Weight, approx. 720 g
Web server
• supported Yes
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1513pro-2 PN
7
With 3 x M12 and 2 x 7/8",
• CPU 1513pro-2 PN for SIMATIC ET 200pro based on for connecting 2 x PROFINET
S7-1500 CPU 1513-1 PN
Industrial Ethernet
• For applications with medium requirements on the program FC RJ45 plug 180
scope and processing speed, for distributed setup via
RJ45 plug connector for
PROFINET IO. Industrial Ethernet with a rugged
• PROFINET IO controller for operating distributed I/O metal enclosure and integrated
on PROFINET insulation displacement contacts
for connecting Industrial Ethernet
• PROFINET I-Device for connecting the CPU FC installation cables;
as an intelligent PROFINET device with a SIMATIC or with 180° cable outlet
non-Siemens PROFINET IO controller • 1 unit 6GK1901-1BB10-2AA0
• PROFINET shared I-Device for 4 controllers • 10 units 6GK1901-1BB10-2AB0
• 50 units 6GK1901-1BB10-2AE0
• PROFINET IO RT/IRT interface with integrated 3-port switch
Industrial Ethernet FastConnect
• Additional PROFINET IO RT interface with separate installation cables
IP address • FastConnect standard cable 6XV1840-2AH10
• Isochronous mode on PROFINET • FastConnect trailing cable 6XV1840-3AH10
• FastConnect marine cable 6XV1840-4AH10
• Integrated motion control functionalities for controlling
speed-controlled and positioning axes, support for external Industrial Ethernet
encoders, output cams/cam tracks and probes FastConnect installation cables
• IE FC TP trailing cable GP 2 x 2; 6XV1870-2D
• OPC UA Server and Client (data access) as runtime option for sold by the meter, max. delivery
the easy connection of SIMATIC ET 200pro to non-Siemens unit 1 000 m;
devices/systems minimum order quantity 20 m.
• IE TP torsion cable GP 2 x 2; 6XV1870-2F
• Integrated web server with the option of creating user-defined sold by the meter, max. delivery
web pages unit 1 000 m;
minimum order quantity 20 m.
Note
Industrial Ethernet FastConnect
SIMATIC Memory Card required for operation of the CPU.
Stripping tool 6GK1901-1GA00
1) An MMC is essential for operating the CPU
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1513pro-2 PN
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1513pro-2 PN
■ Technical specifications
Article number 6ES7513-2PL00-0AB0 Article number 6ES7513-2PL00-0AB0
ET 200pro: CPU 1513pro-2 PN ET 200pro: CPU 1513pro-2 PN
General information PROFINET IO Controller
Product type designation CPU 1513pro-2 PN Services
Engineering with - PG/OP communication Yes
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V16 (FW V2.8) - Isochronous mode Yes
integrated from version or higher - Direct data exchange Yes; Requirement: IRT and
Supply voltage isochronous mode (MRPD optional)
Type of supply voltage 24 V DC - IRT Yes
Memory - PROFIenergy Yes; per user program
Work memory - Prioritized startup Yes; Max. 32 PROFINET devices
• integrated (for program) 300 kbyte - Number of connectable 128; In total, up to 512 distributed I/O
• integrated (for data) 1.5 Mbyte IO Devices, max. devices can be connected via AS-i,
PROFIBUS or PROFINET
Load memory
- Of which IO devices with IRT, max. 64
• Plug-in (SIMATIC Memory Card), 32 Gbyte
max. - Number of connectable 128
IO Devices for RT, max.
CPU processing times
- of which in line, max. 128
for bit operations, typ. 40 ns
7 for word operations, typ. 48 ns
- Number of IO Devices that can
be simultaneously activated/
8; in total across all interfaces
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1513pro-2 PN
■ Technical specifications
Article number 6ES7513-2PL00-0AB0 Article number 6ES7513-2PL00-0AB0
ET 200pro: CPU 1513pro-2 PN ET 200pro: CPU 1513pro-2 PN
PROFINET IO Controller Supported technology objects
Services Motion Control Yes; Note: The number of technology
- PG/OP communication Yes objects affects the cycle time of the
PLC program; selection guide via the
- Isochronous mode No TIA Selection Tool
- Direct data exchange No • Number of available Motion Control 800
- IRT No resources for technology objects
- PROFIenergy Yes • Required Motion Control resources
- Prioritized startup No - per speed-controlled axis 40
- Number of connectable 32; In total, up to 512 distributed I/O - per positioning axis 80
IO Devices, max. devices can be connected via AS-i, - per synchronous axis 160
PROFIBUS or PROFINET
- per external encoder 80
- Number of connectable 32
IO Devices for RT, max. - per output cam 20
- of which in line, max. 32 - per cam track 160
- Number of IO Devices that can 8; in total across all interfaces - per probe 40
be simultaneously activated/ Controller
deactivated, max.
- Number of IO Devices per tool, 8
• PID_Compact Yes; Universal PID controller with
integrated optimization 7
max. • PID_3Step Yes; PID controller with integrated
- Updating times The minimum value of the optimization for valves
update time also depends on • PID-Temp Yes; PID controller with integrated
communication share set for optimization for temperature
PROFINET IO, on the number of
IO devices, and on the quantity of Counting and measuring
configured user data • High-speed counter Yes
PROFINET IO Device Ambient conditions
Services Ambient temperature
- PG/OP communication Yes during operation
- Isochronous mode No • horizontal installation, min. -25 °C
- IRT No • horizontal installation, max. 55 °C
- PROFIenergy Yes; per user program • vertical installation, min. -25 °C
- Prioritized startup No • vertical installation, max. 55 °C
- Shared device Yes Configuration
- Number of IO Controllers with 4 Programming
shared device, max. Programming language
- activation/deactivation of I-devices Yes; per user program - LAD Yes
- Asset management record Yes; per user program - FBD Yes
Protocols - STL Yes
Number of connections - SCL Yes
• Number of connections, max. 128; Via integrated interfaces - GRAPH Yes
of the CPU
Know-how protection
Redundancy mode
• User program protection/ Yes
Media redundancy password protection
- Media redundancy Yes; only via 1st interface (X1) • Copy protection Yes
- MRP Yes; MRP Automanager according • Block protection Yes
to IEC 62439-2 Edition 2.0,
MRP Manager; MRP Client Access protection
- MRP interconnection, supported Yes; as MRP ring node according to • protection of confidential Yes
IEC 62439-2 Edition 3.0 configuration data
- MRPD Yes; Requirement: IRT • Protection level: Write protection Yes
- Switchover time on line break, typ. 200 ms; For MRP, • Protection level: Yes
bumpless for MRPD Read/write protection
- Number of stations in the ring, 50 • Protection level: Yes
max. Complete protection
SIMATIC communication Dimensions
• S7 routing Yes Width 135 mm
OPC UA Height 130 mm
• OPC UA Client Yes Depth 65 mm
• OPC UA Server Yes; Data access Weights
(read, write, subscribe), method call, Weight, approx. 614 g
custom address space
• Alarms and Conditions Yes
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1516pro-2 PN
7
With 3 x M12 and 2 x 7/8",
• CPU 1516pro-2 PN for SIMATIC ET 200pro based on for connecting 2 x PROFINET
S7-1500 CPU 1516-3 PN/DP
Industrial Ethernet FC RJ45
• For applications with high requirements on the program scope plug 180
and processing speed, for distributed setup via PROFINET IO
RJ45 plug connector for
• PROFINET IO controller for operating distributed I/O Industrial Ethernet with a rugged
on PROFINET metal enclosure and integrated
insulation displacement contacts
• PROFINET I-Device for connecting the CPU for connecting Industrial Ethernet
as an intelligent PROFINET device with a SIMATIC or FC installation cables;
non-Siemens PROFINET IO controller with 180° cable outlet
• 1 unit 6GK1901-1BB10-2AA0
• PROFINET shared I-Device for 4 controllers
• 10 units 6GK1901-1BB10-2AB0
• PROFINET IO RT/IRT interface with integrated 3-port switch • 50 units 6GK1901-1BB10-2AE0
• Additional PROFINET IO RT interface with separate Industrial Ethernet FastConnect
IP address installation cables
• Isochronous mode on PROFINET • FastConnect standard cable 6XV1840-2AH10
• FastConnect trailing cable 6XV1840-3AH10
• Integrated Motion Control functionalities for controlling
• FastConnect marine cable 6XV1840-4AH10
speed-controlled and positioning axes, support for external
encoders, output cams/cam tracks and probes Industrial Ethernet
FastConnect installation cables
• OPC UA Server and Client (Data Access) as runtime option for • IE FC TP trailing cable GP 2 x 2; 6XV1870-2D
the easy connection of SIMATIC ET 200pro to non-Siemens sold by the meter, max. delivery
devices/systems unit 1 000 m;
minimum order quantity 20 m.
• Integrated web server with the option of creating user-defined
• IE TP torsion cable GP 2 x 2; 6XV1870-2F
web pages sold by the meter, max. delivery
Note unit 1 000 m;
minimum order quantity 20 m.
SIMATIC Memory Card required for operation of the CPU Industrial Ethernet FastConnect
Stripping tool 6GK1901-1GA00
1) An MMC is essential for operating the CPU
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1516pro-2 PN
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1516pro-2 PN
■ Technical specifications
Article number 6ES7516-2PN00-0AB0 Article number 6ES7516-2PN00-0AB0
ET 200pro: CPU 1516PRO-2 PN ET 200pro: CPU 1516PRO-2 PN
General information PROFINET IO Controller
Product type designation CPU 1516pro-2 PN Services
Engineering with - PG/OP communication Yes
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V14 (FW V2.0) or - Isochronous mode Yes
integrated from version higher - Direct data exchange Yes; Requirement: IRT and
Supply voltage isochronous mode (MRPD optional)
Type of supply voltage 24 V DC - IRT Yes
Memory - PROFIenergy Yes; per user program
Work memory - Prioritized startup Yes; Max. 32 PROFINET devices
• integrated (for program) 1 Mbyte - Number of connectable 256; In total, up to 1 000 distributed
• integrated (for data) 5 Mbyte IO Devices, max. I/O devices can be connected via
AS-i, PROFIBUS or PROFINET
Load memory
- Of which IO devices with IRT, max. 64
• Plug-in (SIMATIC Memory Card), 32 Gbyte
max. - Number of connectable 256
IO Devices for RT, max.
CPU processing times
- of which in line, max. 256
for bit operations, typ. 10 ns
7 for word operations, typ. 12 ns
- Number of IO Devices that can
be simultaneously activated/
8; in total across all interfaces
Distributed Controllers
based on ET 200Pro
Standard CPUs
CPU 1516pro-2 PN
■ Technical specifications
Article number 6ES7516-2PN00-0AB0 Article number 6ES7516-2PN00-0AB0
ET 200pro: CPU 1516PRO-2 PN ET 200pro: CPU 1516PRO-2 PN
PROFINET IO Controller Supported technology objects
Services Motion Control Yes; Note: The number of technology
- PG/OP communication Yes objects affects the cycle time of the
PLC program; selection guide via the
- Isochronous mode No TIA Selection Tool
- Direct data exchange No • Number of available Motion Control 2 400
- IRT No resources for technology objects
- PROFIenergy Yes; per user program • Required Motion Control resources
- Prioritized startup No - per speed-controlled axis 40
- Number of connectable 32; In total, up to 1 000 distributed - per positioning axis 80
IO Devices, max. I/O devices can be connected via - per synchronous axis 160
AS-i, PROFIBUS or PROFINET
- per external encoder 80
- Number of connectable 32
IO Devices for RT, max. - per output cam 20
- of which in line, max. 32 - per cam track 160
- Number of IO Devices that can 8; in total across all interfaces - per probe 40
be simultaneously activated/ Controller
deactivated, max.
- Number of IO Devices per tool, 8
• PID_Compact Yes; Universal PID controller with
integrated optimization 7
max. • PID_3Step Yes; PID controller with integrated
- Updating times The minimum value of the optimization for valves
update time also depends on • PID-Temp Yes; PID controller with integrated
communication share set for optimization for temperature
PROFINET IO, on the number of
IO devices, and on the quantity of Counting and measuring
configured user data • High-speed counter Yes
PROFINET IO Device Ambient conditions
Services Ambient temperature
- PG/OP communication Yes during operation
- Isochronous mode No • horizontal installation, min. -25 °C
- IRT No • horizontal installation, max. 55 °C
- PROFIenergy Yes; per user program • vertical installation, min. -25 °C
- Prioritized startup No • vertical installation, max. 55 °C
- Shared device Yes Configuration
- Number of IO Controllers 4 Programming
with shared device, max. Programming language
- activation/deactivation of I-devices Yes; per user program - LAD Yes
- Asset management record Yes; per user program - FBD Yes
Protocols - STL Yes
Number of connections - SCL Yes
• Number of connections, max. 128; Via integrated interfaces - GRAPH Yes
of the CPU
Know-how protection
Redundancy mode
• User program protection/ Yes
Media redundancy password protection
- Media redundancy Yes; only via 1st interface (X1) • Copy protection Yes
- MRP Yes; MRP Automanager according to • Block protection Yes
IEC 62439-2 Edition 2.0,
MRP Manager; MRP Client Access protection
- MRP interconnection, supported Yes; as MRP ring node according to • protection of confidential Yes
IEC 62439-2 Edition 3.0 configuration data
- MRPD Yes; Requirement: IRT • Protection level: Write protection Yes
- Switchover time on line break, typ. 200 ms; For MRP, • Protection level: Yes
bumpless for MRPD Read/write protection
- Number of stations in the ring, 50 • Protection level: Yes
max. Complete protection
SIMATIC communication Dimensions
• S7 routing Yes Width 135 mm
OPC UA Height 130 mm
• OPC UA Client Yes Depth 65 mm
• OPC UA Server Yes; Data access Weights
(read, write, subscribe), method call, Weight, approx. 614 g
custom address space
• Alarms and Conditions Yes
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
IM 154-8 F PN/DP CPU
7 • Interface module for SIMATIC ET 200pro with integrated Windows Server 2008 R2 SP1
(64-bit),
fail-safe CPU Windows Server 2012 R2 (64-bit),
• CPU with PLC functionality equivalent to CPU S7-315F PN/DP; Windows Server 2016 (64-bit);
with distributed intelligence for preprocessing STEP 7 as of V5.5 SP1;
Please also consider the operating
• For constructing a fail-safe automation system for plants systems that have been released
with increased safety requirements for the used STEP 7 version
• Complies with safety requirements up to SIL 3 Floating license for 1 user; 6ES7833-1FC02-0YA5
according to IEC 61508, IEC 62061 and PL e software and documentation on
DVD; license key on USB flash drive
according to ISO 13849.1:2006
Floating license for 1 user; 6ES7833-1FC02-0YH5
• For high-performance control solutions in ET 200pro software, documentation and
• Increase in availability of systems and machines license key for download1);
Email address required for delivery
• Integral web server with the option of creating user-defined
web pages S7 Distributed Safety upgrade
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
IM 154-8 F PN/DP CPU
MMC 2 MB 2)
6ES7953-8LL31-0AA0 Stripping tool 6GK1901-1GA00
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
IM 154-8 F PN/DP CPU
7
- 3.0 m 3RK1902-3NB30 Other special lengths See
- 5.0 m 3RK1902-3NB50 with 90° or 180° cable outlet http://support.automation.siemens.
- 10 m 3RK1902-3NC10 com/WW/view/en/26999294
• Trailing power cable, 5 x 1.5 mm2, M12 bus termination connector 6GK1905-0ED00
pre-assembled at one end with for PROFIBUS, female contact
7/8" angled plug with female insert
contact insert (female contact
insert at one end, other end open), M12 bus termination connector 6GK1905-0EC00
in various lengths: for PROFIBUS, male contact
- 3.0 m 3RK1902-3GB30 insert
- 5.0 m 3RK1902-3GB50 M12 plug connector, axial outlet, 6GK1905-0EA00
- 10 m 3RK1902-3GC10 with male contact insert
Power line 6XV1830-8AH10 PROFIBUS FC standard cable GP 6XV1830-0EH10
5-wire, 5 x 1.5 mm2, trailing type, Standard type with special design
sold by the meter, for quick mounting, 2-wire,
minimum order quantity 20 m, shielded.
maximum order quantity 1 000 m. Sold by the meter;
7/8" connection plug max. delivery unit 1 000 m,
minimum order quantity 20 m.
For ET 200eco,
with axial cable outlet PROFIBUS FC trailing cable 6XV1830-3EH10
• With male contact insert, 5-pack 6GK1905-0FA00 2-wire, shielded.
• With female contact insert, 5-pack 6GK1905-0FB00
PROFIBUS FC food cable 6XV1830-0GH10
• Angled, with female contact insert, 3RK1902-3DA00
1 unit 2-wire, shielded.
• Angled, with male contact insert, 3RK1902-3BA00 Sold by the meter;
1 unit max. delivery unit 1 000 m,
7/8" cover cap, 10 per pack 6ES7194-3JA00-0AA0 minimum order quantity 20 m.
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
IM 154-8 F PN/DP CPU
■ Technical specifications
Article number 6ES7154-8FB01-0AB0 6ES7154-8FX00-0AB0
ET 200pro: IM 154-8F PN/DP CPU, 512KB ET 200pro: IM 154-8FX PN/DP CPU, 1,5MB
General information
Product function
• Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface Yes; Via PROFIBUS DP or PROFINET interface
Supply voltage
Rated value (DC) 24 V 24 V
Power loss
Power loss, typ. 8.5 W 8.5 W
Memory
Work memory
• integrated 512 kbyte 1 536 kbyte
• expandable No No
Load memory
• Plug-in (MMC), max. 8 Mbyte 8 Mbyte
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs
for word operations, typ.
for fixed point arithmetic, typ.
0.09 µs
0.12 µs
0.03 µs
0.04 µs
7
for floating point arithmetic, typ. 0.45 µs 0.16 µs
Counters, timers and their
retentivity
S7 counter
• Number 256 256
IEC counter
• present Yes Yes
S7 times
• Number 256 256
IEC timer
• present Yes Yes
Data areas and their retentivity
Flag
• Size, max. 2 048 byte 2 048 byte
Address area
I/O address area
• Inputs 2 048 byte 2 048 byte
• Outputs 2 048 byte 2 048 byte
Process image
• Inputs, adjustable 2 048 byte 2 048 byte
• Outputs, adjustable 2 048 byte 2 048 byte
Time of day
Clock
• Hardware clock (real-time) Yes Yes
Operating hours counter
• Number 1 1
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface
Interface types
• RS 485 Yes Yes
Protocols
• MPI Yes Yes
• PROFIBUS DP master Yes Yes
• PROFIBUS DP slave Yes Yes
• Point-to-point connection No No
PROFIBUS DP master
• Number of DP slaves, max. 124 124
2. Interface
Interface types
• Number of ports 3 3
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
IM 154-8 F PN/DP CPU
■ Technical specifications
Article number 6ES7154-8FB01-0AB0 6ES7154-8FX00-0AB0
ET 200pro: IM 154-8F PN/DP CPU, 512KB ET 200pro: IM 154-8FX PN/DP CPU, 1,5MB
Protocols
• MPI No No
• PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality Yes; Also simultaneously with IO-Device functionality
• PROFINET IO Device Yes; Also simultaneously with IO Controller functionality Yes; Also simultaneously with IO Controller functionality
• PROFINET CBA Yes Yes
• PROFIBUS DP master No No
• PROFIBUS DP slave No No
PROFINET IO Controller
Services
- Number of connectable 128 128
IO Devices, max.
- Of which IO devices with IRT, max. 64 64
- Number of IO Devices with IRT and 128 128
the option "high flexibility"
- Number of connectable 128 128
IO Devices for RT, max.
7 Protocols
SIMATIC communication
• S7 routing Yes Yes
Open IE communication
• TCP/IP Yes; via integrated PROFINET interface and loadable FBs Yes; via integrated PROFINET interface and loadable FBs
- Number of connections, max. 8 8
• ISO-on-TCP (RFC1006) Yes Yes
- Number of connections, max. 8 8
• UDP Yes Yes
- Number of connections, max. 8 8
Web server
• supported Yes Yes
Communication functions
PG/OP communication Yes Yes
Global data communication
• supported Yes Yes
S7 basic communication
• supported Yes Yes
S7 communication
• supported Yes Yes
Number of connections
• overall 16 16
Configuration
Programming
Programming language
- LAD Yes Yes
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- CFC Yes Yes
- GRAPH Yes Yes
- HiGraph® Yes Yes
Know-how protection
• User program protection/ Yes Yes
password protection
• Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 135 mm 135 mm
Height 130 mm 130 mm
Depth 65 mm; 60 mm without cover for RJ45 socket; 65 mm; 60 mm without cover for RJ45 socket;
65 mm with cover for RJ45 socket 65 mm with cover for RJ45 socket
Weights
Weight, approx. 720 g 720 g
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1513pro F-2 PN
7
With 3 x M12 and 2 x 7/8",
• Fail-safe CPU 1513pro F-2 PN for SIMATIC ET 200pro for connecting 2 x PROFINET
based on S7-1500 CPU 1513F-1 PN
Industrial Ethernet
• For applications with medium requirements on the FC RJ45 plug 180
program scope and processing speed, for distributed setup
RJ45 plug connector for
via PROFINET IO. Industrial Ethernet with a rugged
• Can be used for safety functions up to SIL 3 according to metal enclosure and integrated
IEC 61508 and up to PL e according to ISO 13849 insulation displacement contacts
for connecting Industrial Ethernet
• PROFINET IO controller for operating distributed I/O FC installation cables;
on PROFINET with 180° cable outlet
• 1 unit 6GK1901-1BB10-2AA0
• PROFINET I-Device for connecting the CPU
as an intelligent PROFINET device with a SIMATIC or • 10 units 6GK1901-1BB10-2AB0
non-Siemens PROFINET IO controller • 50 units 6GK1901-1BB10-2AE0
• Integrated web server with the option of creating user-defined Industrial Ethernet FastConnect
web pages Stripping tool 6GK1901-1GA00
1)
Note An MMC is essential for operating the CPU
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1513pro F-2 PN
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1513pro F-2 PN
■ Technical specifications
Article number 6ES7513-2GL00-0AB0 Article number 6ES7513-2GL00-0AB0
ET 200pro: CPU 1513pro F-2 PN ET 200pro: CPU 1513pro F-2 PN
General information PROFINET IO Controller
Product type designation CPU 1513pro F-2 PN Services
Engineering with - PG/OP communication Yes
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V16 (FW V2.8) - Isochronous mode Yes
integrated from version or higher - Direct data exchange Yes; Requirement: IRT and
Supply voltage isochronous mode (MRPD optional)
Type of supply voltage 24 V DC - IRT Yes
Memory - PROFIenergy Yes; per user program
Work memory - Prioritized startup Yes; Max. 32 PROFINET devices
• integrated (for program) 450 kbyte - Number of connectable 128; In total, up to 512 distributed I/O
• integrated (for data) 1.5 Mbyte IO Devices, max. devices can be connected via AS-i,
PROFIBUS or PROFINET
Load memory
- Of which IO devices with IRT, max. 64
• Plug-in (SIMATIC Memory Card), 32 Gbyte
max. - Number of connectable 128
IO Devices for RT, max.
CPU processing times
- of which in line, max. 128
for bit operations, typ. 40 ns
for word operations, typ. 48 ns
- Number of IO Devices that can
be simultaneously activated/
8; in total across all interfaces
7
for fixed point arithmetic, typ. 64 ns deactivated, max.
for floating point arithmetic, typ. 256 ns - Number of IO Devices per tool, 8
max.
Counters, timers and their
retentivity - Updating times The minimum value of the
update time also depends on
S7 counter communication share set for
• Number 2 048 PROFINET IO, on the number of
IO devices, and on the quantity of
IEC counter
configured user data
• Number Any
PROFINET IO Device
(only limited by the main memory)
Services
S7 times
- PG/OP communication Yes
• Number 2 048
- Isochronous mode No
IEC timer
- IRT Yes
• Number Any
(only limited by the main memory) - PROFIenergy Yes; per user program
Data areas and their retentivity - Prioritized startup No
Flag - Shared device Yes
• Size, max. 16 kbyte - Number of IO Controllers 4
with shared device, max.
Address area
- activation/deactivation of I-devices Yes; per user program
I/O address area
- Asset management record Yes; per user program
• Inputs 32 kbyte; All inputs are in the
process image 2. Interface
• Outputs 32 kbyte; All outputs are in the Interface types
process image • RJ 45 (Ethernet) No
Time of day • Number of ports 1; 1x M12
Clock • integrated switch No
• Type Hardware clock Protocols
1. Interface • IP protocol Yes; IPv4
Interface types • PROFINET IO Controller Yes
• RJ 45 (Ethernet) Yes; X1 P3 • PROFINET IO Device Yes
• Number of ports 3; 2x M12 + 1x RJ45 • SIMATIC communication Yes
• integrated switch Yes • Open IE communication Yes; Optionally also encrypted
Protocols • Web server Yes
• IP protocol Yes; IPv4 • Media redundancy No
• PROFINET IO Controller Yes
• PROFINET IO Device Yes
• SIMATIC communication Yes
• Open IE communication Yes; Optionally also encrypted
• Web server Yes
• Media redundancy Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1513pro F-2 PN
■ Technical specifications
Article number 6ES7513-2GL00-0AB0 Article number 6ES7513-2GL00-0AB0
ET 200pro: CPU 1513pro F-2 PN ET 200pro: CPU 1513pro F-2 PN
PROFINET IO Controller • Number of available Motion Control 800
Services resources for technology objects
- PG/OP communication Yes • Required Motion Control resources
- Isochronous mode No - per speed-controlled axis 40
- Direct data exchange No - per positioning axis 80
- IRT No - per synchronous axis 160
- PROFIenergy Yes - per external encoder 80
- Prioritized startup No - per output cam 20
- Number of connectable 32; In total, up to 512 distributed I/O - per cam track 160
IO Devices, max. devices can be connected via AS-i, - per probe 40
PROFIBUS or PROFINET Controller
- Number of connectable 32 • PID_Compact Yes; Universal PID controller with
IO Devices for RT, max. integrated optimization
- of which in line, max. 32 • PID_3Step Yes; PID controller with integrated
- Number of IO Devices that can 8; in total across all interfaces optimization for valves
be simultaneously activated/ • PID-Temp Yes; PID controller with integrated
7 deactivated, max.
- Number of IO Devices per tool, 8 Counting and measuring
optimization for temperature
max.
• High-speed counter Yes
- Updating times The minimum value of the
update time also depends on Standards, approvals, certificates
communication share set for Highest safety class achievable
PROFINET IO, on the number of in safety mode
IO devices, and on the quantity of
configured user data Probability of failure
(for service life of 20 years and
PROFINET IO Device repair time of 100 hours)
Services - Low demand mode: < 2.00E-05
- PG/OP communication Yes PFDavg in accordance with SIL3
- Isochronous mode No - High demand/continuous mode: < 1.00E-09
PFH in accordance with SIL3
- IRT No
Ambient conditions
- PROFIenergy Yes; per user program
Ambient temperature
- Prioritized startup No during operation
- Shared device Yes • horizontal installation, min. -25 °C
- Number of IO Controllers 4 • horizontal installation, max. 55 °C
with shared device, max.
• vertical installation, min. -25 °C
- activation/deactivation of I-devices Yes; per user program
• vertical installation, max. 55 °C
- Asset management record Yes; per user program
Configuration
Protocols
Programming
Number of connections
Programming language
• Number of connections, max. 128; Via integrated interfaces
of the CPU - LAD Yes; incl. failsafe
Redundancy mode - FBD Yes; incl. failsafe
Media redundancy - STL Yes
- Media redundancy Yes; only via 1st interface (X1) - SCL Yes
- MRP Yes; MRP Automanager according to - GRAPH Yes
IEC 62439-2 Edition 2.0, Know-how protection
MRP Manager; MRP Client
• User program protection/ Yes
- MRP interconnection, supported Yes; as MRP ring node according to password protection
IEC 62439-2 Edition 3.0
• Copy protection Yes
- MRPD Yes; Requirement: IRT
• Block protection Yes
- Switchover time on line break, typ. 200 ms; For MRP,
bumpless for MRPD Access protection
- Number of stations in the ring, 50 • protection of confidential Yes
max. configuration data
SIMATIC communication • Protection level: Write protection Yes
• S7 routing Yes • Protection level: Yes
Read/write protection
OPC UA
• Protection level: Yes
• OPC UA Client Yes Complete protection
• OPC UA Server Yes; Data access Dimensions
(read, write, subscribe), method call,
custom address space Width 135 mm
Supported technology objects Height 130 mm
Motion Control Yes; Note: The number of technology Depth 65 mm
objects affects the cycle time of the Weights
PLC program; selection guide via the
Weight, approx. 614 g
TIA Selection Tool
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1516pro F-2 PN
■ Overview
• PROFINET I-Device for connecting the CPU
as an intelligent PROFINET device with a SIMATIC or
non-Siemens PROFINET IO controller
• Supports PROFIsafe in centralized and distributed
configurations
• PROFINET shared I-Device for 4 controllers
• PROFINET IO RT/IRT interface with integrated 3-port switch
• Additional PROFINET IO RT interface with separate
IP address
• Isochronous mode on PROFINET
• Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes, support for external
encoders
• OPC UA Server and Client (Data Access) as runtime option for
the easy connection of SIMATIC ET 200pro to non-Siemens
devices/systems
• Integrated web server with the option of creating user-defined
web pages
• Fail-safe CPU 1516pro F-2 PN for SIMATIC ET 200pro
based on S7-1500 CPU 1516F-3 PN/DP Note
7
• For applications with high requirements on the program scope SIMATIC Memory Card required for operation of the CPU.
and processing speed, for distributed setup via PROFINET IO
• Can be used for safety functions up to SIL 3 according to
IEC 61508 and up to PL e according to ISO 13849
• PROFINET IO controller for operating distributed I/O
on PROFINET
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1516pro F-2 PN
■ Technical specifications
Article number 6ES7516-2GN00-0AB0 Article number 6ES7516-2GN00-0AB0
ET 200pro: CPU 1516PRO F-2 PN ET 200pro: CPU 1516PRO F-2 PN
General information CPU processing times
Product type designation CPU 1516pro F-2 PN for bit operations, typ. 10 ns
Engineering with for word operations, typ. 12 ns
• STEP 7 TIA Portal configurable/ V17 (FW V2.9) / V14 (FW V2.0) for fixed point arithmetic, typ. 16 ns
integrated from version or higher for floating point arithmetic, typ. 64 ns
Supply voltage Counters, timers and their
Type of supply voltage 24 V DC retentivity
Memory S7 counter
Work memory • Number 2 048
• integrated (for program) 1.5 Mbyte IEC counter
• integrated (for data) 5 Mbyte • Number Any
Load memory (only limited by the main memory)
• Plug-in (SIMATIC Memory Card), 32 Gbyte S7 times
max. • Number 2 048
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1516pro F-2 PN
■ Technical specifications
Article number 6ES7516-2GN00-0AB0 Article number 6ES7516-2GN00-0AB0
ET 200pro: CPU 1516PRO F-2 PN ET 200pro: CPU 1516PRO F-2 PN
IEC timer PROFINET IO Device
• Number Any Services
(only limited by the main memory) - PG/OP communication Yes
Data areas and their retentivity - Isochronous mode No
Flag - IRT Yes
• Size, max. 16 kbyte - PROFIenergy Yes; per user program
Address area - Prioritized startup No
I/O address area - Shared device Yes
• Inputs 32 kbyte; All inputs are in the - Number of IO Controllers with 4
process image shared device, max.
• Outputs 32 kbyte; All outputs are in the - activation/deactivation of I-devices Yes; per user program
process image
- Asset management record Yes; per user program
Time of day
2. Interface
Clock
Interface types
• Type Hardware clock
• RJ 45 (Ethernet) No
1. Interface
Interface types
• RJ 45 (Ethernet) Yes; X1 P3
• Number of ports
• integrated switch
1; 1x M12
No 7
Protocols
• Number of ports 3; 2x M12 + 1x RJ45
• IP protocol Yes; IPv4
• integrated switch Yes
• PROFINET IO Controller Yes
Protocols
• PROFINET IO Device Yes
• IP protocol Yes; IPv4
• SIMATIC communication Yes
• PROFINET IO Controller Yes
• Open IE communication Yes; Optionally also encrypted
• PROFINET IO Device Yes
• Web server Yes
• SIMATIC communication Yes
• Media redundancy No
• Open IE communication Yes; Optionally also encrypted
PROFINET IO Controller
• Web server Yes
Services
• Media redundancy Yes; MRP Automanager according to
IEC 62439-2 Edition 2.0 - PG/OP communication Yes
PROFINET IO Controller - Isochronous mode No
Services - Direct data exchange No
- PG/OP communication Yes - IRT No
- Isochronous mode Yes - PROFIenergy Yes; per user program
- Direct data exchange Yes; Requirement: IRT and - Prioritized startup No
isochronous mode (MRPD optional) - Number of connectable 32; In total, up to 1 000 distributed
- IRT Yes IO Devices, max. I/O devices can be connected via
AS-i, PROFIBUS or PROFINET
- PROFIenergy Yes; per user program
- Number of connectable 32
- Prioritized startup Yes; Max. 32 PROFINET devices IO Devices for RT, max.
- Number of connectable 256; In total, up to 1 000 distributed - of which in line, max. 32
IO Devices, max. I/O devices can be connected via
AS-i, PROFIBUS or PROFINET - Number of IO Devices that can 8; in total across all interfaces
be simultaneously activated/
- Of which IO devices with IRT, max. 64 deactivated, max.
- Number of connectable 256 - Number of IO Devices per tool, 8
IO Devices for RT, max. max.
- of which in line, max. 256 - Updating times The minimum value of the
- Number of IO Devices that can 8; in total across all interfaces update time also depends on
be simultaneously activated/ communication share set for
deactivated, max. PROFINET IO, on the number of
- Number of IO Devices per tool, 8 IO devices, and on the quantity of
max. configured user data
- Updating times The minimum value of the
update time also depends on
communication share set for
PROFINET IO, on the number of
IO devices, and on the quantity of
configured user data
Distributed Controllers
based on ET 200Pro
Fail-safe CPUs
CPU 1516pro F-2 PN
■ Technical specifications
Article number 6ES7516-2GN00-0AB0 Article number 6ES7516-2GN00-0AB0
ET 200pro: CPU 1516PRO F-2 PN ET 200pro: CPU 1516PRO F-2 PN
PROFINET IO Device Standards, approvals, certificates
Services Highest safety class achievable
- PG/OP communication Yes in safety mode
- Isochronous mode No Probability of failure
(for service life of 20 years and
- IRT No repair time of 100 hours)
- PROFIenergy Yes; per user program - Low demand mode: < 2.00E-05
- Prioritized startup No PFDavg in accordance with SIL3
- Shared device Yes - High demand/continuous mode: < 1.00E-09
PFH in accordance with SIL3
- Number of IO Controllers 4
with shared device, max. Ambient conditions
- activation/deactivation of I-devices Yes; per user program Ambient temperature
during operation
- Asset management record Yes; per user program
• horizontal installation, min. -25 °C
Protocols
• horizontal installation, max. 55 °C
Number of connections
• vertical installation, min. -25 °C
• Number of connections, max. 128; Via integrated interfaces of the
• vertical installation, max. 55 °C
7
CPU
Redundancy mode Configuration
Media redundancy Programming
- Media redundancy Yes; only via 1st interface (X1) Programming language
- MRP Yes; MRP Automanager according to - LAD Yes; incl. failsafe
IEC 62439-2 Edition 2.0, - FBD Yes; incl. failsafe
MRP Manager; MRP Client
- STL Yes
- MRP interconnection, supported Yes; as MRP ring node according to
IEC 62439-2 Edition 3.0 - SCL Yes
- MRPD Yes; Requirement: IRT - GRAPH Yes
- Switchover time on line break, typ. 200 ms; For MRP, Know-how protection
bumpless for MRPD • User program protection/ Yes
- Number of stations in the ring, 50 password protection
max. • Copy protection Yes
SIMATIC communication • Block protection Yes
• S7 routing Yes Access protection
OPC UA • protection of confidential Yes
• OPC UA Client Yes configuration data
• OPC UA Server Yes; Data access • Protection level: Write protection Yes
(read, write, subscribe), method call, • Protection level: Yes
custom address space Read/write protection
• Alarms and Conditions Yes • Protection level: Yes
Supported technology objects Complete protection
Motion Control Yes; Note: The number of technology Dimensions
objects affects the cycle time of the Width 135 mm
PLC program; selection guide via the Height 130 mm
TIA Selection Tool
Depth 65 mm
• Number of available Motion Control 800
resources for technology objects Weights
• Required Motion Control resources Weight, approx. 614 g
- per speed-controlled axis 40
- per positioning axis 80
- per synchronous axis 160
- per external encoder 80
- per output cam 20
- per cam track 160
- per probe 40
Controller
• PID_Compact Yes; Universal PID controller with
integrated optimization
• PID_3Step Yes; PID controller with integrated
optimization for valves
• PID-Temp Yes; PID controller with integrated
optimization for temperature
Counting and measuring
• High-speed counter Yes
Software Controllers
Siemens ST 70 · 2021
© Siemens 2021
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1507S
■ Overview
• Software Controller for implementing the functions of a
SIMATIC S7-1500 Controller on a SIMATIC IPC
• For use as a PC-based PLC in machines with distributed I/O
via PROFINET and PROFIBUS
• For utilizing IPC onboard interfaces and PC plug-in cards
for PROFINET and PROFIBUS connections
• Optimized for PC-based control tasks with the
IPC427E Microbox PC and the IPC477E Panel PC
• Can also be used on the IPC227E, IPC627D, IPC627E
and IPC827D Box PCs, the IPC277E, IPC677D and
IPC677E Panel PCs, and the IPC647D, IPC647E, IPC847D
and IPC847E Rack PCs
• Execution of functions and algorithms implemented with
high-level languages under Windows (C/C++, C#, VB) and
locally in the CPU 1507S (C/C++)
• Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes as well as synchronous
operation, support for external encoders, precise position
gearing between axes, output cams/cam tracks and probes
• Integrated web server for diagnostics with the option of
creating user-defined web pages
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1507S
■ Technical specifications
Article number 6ES7672-7AC01-0YA0 Article number 6ES7672-7AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1507S CPU 1507S
General information Protocols
Product type designation CPU 1507S • PROFINET IO Controller Yes
Engineering with • PROFINET IO Device Yes
• STEP 7 TIA Portal configurable/ V16 with HSP 287 • SIMATIC communication Yes
integrated from version • Open IE communication Yes
Memory • Web server Yes
Work memory • Media redundancy Yes; MRP Automanager according to
• integrated (for program) 5 Mbyte IEC 62439-2 Edition 2.0
• integrated (for data) 20 Mbyte PROFINET IO Controller
• integrated (for CPU function library 50 Mbyte Services
of CPU Runtime) - Isochronous mode Yes
Load memory - Direct data exchange Yes; Requirement: IRT and
• integrated (on PC mass storage) 320 Mbyte isochronous mode (MRPD optional)
CPU processing times - shortest clock pulse 500 µs
for bit operations, typ. 1 ns; On IPC427E, - IRT Yes
Intel Xeon processor - PROFIenergy Yes
for word operations, typ. 2 ns; On IPC427E, - Prioritized startup Yes; max. 32 PROFINET devices;
Intel Xeon processor if you want to use the "Prioritized
for fixed point arithmetic, typ. 2 ns; On IPC427E, startup" functionality in STEP7 for the
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1507S
■ Technical specifications
Article number 6ES7672-7AC01-0YA0 Article number 6ES7672-7AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1507S CPU 1507S
2. Interface 3. Interface
Interface type Onboard PROFINET / IE interface Interface type PROFIBUS with CP 5622,
X2/X3 of the SIMATIC IPC, CP 5622 onboard
Intel Springville i210T Number of connections 44
Number of connections 128 via this interface
via this interface Interface types
Interface types • RS 485 Yes
• RJ 45 (Ethernet) Yes Protocols
- Transmission rate, max. 100 Mbit/s • PROFIBUS DP master Yes
- Industrial Ethernet status LED Yes • PROFIBUS DP slave No
• Number of ports 1 • SIMATIC communication Yes; no PG/STEP 7 connection
• integrated switch No possible
Protocols PROFIBUS DP master
• PROFINET IO Controller Yes • Number of DP slaves, max. 64
• PROFINET IO Device Yes Services
• SIMATIC communication Yes - Equidistance No
• Open IE communication Yes - Isochronous mode No
• Web server Yes Address area
8 • Media redundancy
PROFINET IO Controller
No - Inputs, max.
- Outputs, max.
8 kbyte
8 kbyte
Services 4. Interface
- Isochronous mode No Interface type PROFIBUS with CP 5623
- IRT No Number of connections 44
- PROFIenergy Yes via this interface
- Prioritized startup Yes; max. 32 PROFINET devices; Interface types
if you want to use the "Prioritized • RS 485 Yes
startup" functionality in STEP 7 for Protocols
the PROFINET interface of the CPU,
the CPU and the device must be • PROFIBUS DP master Yes
separated by means of a switch • PROFIBUS DP slave No
(e.g. SCALANCE X205)
• SIMATIC communication Yes; no PG/STEP 7 connection
- Number of connectable 128 possible
IO Devices for RT, max.
PROFIBUS DP master
- of which in line, max. 128
• Number of DP slaves, max. 125
- Number of IO Devices that can 8
be simultaneously activated/ Protocols
deactivated, max. Number of connections
- Number of IO Devices per tool, 8 • Number of connections, max. 128
max.
Redundancy mode
- Updating times The minimum value of the
Media redundancy
update time also depends on
communication share set for - MRP Yes
PROFINET IO, on the number of - MRPD Yes; Requirement: IRT
IO devices, and on the quantity of
configured user data - Switchover time on line break, typ. 200 ms; For MRP,
bumpless for MRPD
Address area
- Number of stations in the ring, 50
- Inputs, max. 8 kbyte max.
- Outputs, max. 8 kbyte SIMATIC communication
PROFINET IO Device • S7 routing Yes
Services OPC UA
- Isochronous mode No • OPC UA Client Yes; Data access (read, write),
- IRT No method call
- PROFIenergy Yes • OPC UA Server Yes; Data access
(read, write, subscribe), method call,
- Shared device Yes
custom address space
- Number of IO Controllers with 4
shared device, max.
- Asset management record Yes
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1507S
■ Technical specifications
Article number 6ES7672-7AC01-0YA0 Article number 6ES7672-7AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1507S CPU 1507S
Supported technology objects Operating systems
Motion Control Yes; Note: The number of technology Runs under operating system
objects affects the cycle time of the • Windows 7 Yes; Professional, Enterprise,
PLC program; selection guide via the Ultimate (32 bit and 64 bit);
TIA Selection Tool or SIZER Windows Embedded Standard 7 with
• Number of available Motion Control 4 800 delivery image of the SIMATIC IPC
resources for technology objects • Windows 10 Yes; Windows 10 Enterprise 2016
• Required Motion Control resources LTSB, 64-bit, MUI on IPC2x7E,
- per speed-controlled axis 40 IPC4x7E, IPC6x7D, IPC8x7D;
Windows 10 Enterprise 2019 LTSC
- per positioning axis 80 64-bit, MUI on IPC2x7E, IPC4x7E,
- per synchronous axis 160 IPC6x7E, IPC8x7E
- per external encoder 80 Configuration
- per output cam 20 Programming
- per cam track 160 Programming language
- per probe 40 - LAD Yes
Controller - FBD Yes
• PID_Compact Yes; Universal PID controller with - STL Yes
integrated optimization - SCL Yes
• PID_3Step Yes; PID controller with integrated - CFC No
• PID-Temp
optimization for valves
Yes; PID controller with integrated
- GRAPH
Know-how protection
Yes 8
optimization for temperature
Counting and measuring • User program protection/ Yes
password protection
• High-speed counter Yes
• Copy protection Yes
Hardware requirement
• Block protection Yes
Hardware required SIMATIC IPC2x7E, IPC4x7D/E,
IPC6x7D/E, IPC8x7D/E Access protection
Processor • Protection level: Write protection Yes
• Single-core processor No • Protection level: Yes
Read/write protection
• Single-core processor No
with hyper-threading • Protection level: Yes
Complete protection
• Multi-core processor Yes
Open Development interfaces
• Multi-core processor Yes
with hyper-threading • Size of ODK SO file, max. 9.8 Mbyte
• occupied cores 1; For multicore processors
with activated Hyper-Threading,
one complete physical core is
reserved for the CPU 1507S
Memory
• Work memory, min. 4 Gbyte
• Hard disk memory required 720 Mbyte
for installation
• Temporary hard disk memory 230 Mbyte
for installation
• Hard disk memory required 400 Mbyte
at runtime
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1508S
■ Overview
• Software Controller for implementing the functions of a
SIMATIC S7-1500 Controller on a SIMATIC IPC
• For use with control applications with increased requirements
for program and data memory
• For use as a PC-based PLC in machines with distributed I/O
via PROFINET and PROFIBUS
• For utilizing IPC onboard interfaces and PC plug-in cards
for PROFINET and PROFIBUS connections
• Optimized for PC-based control tasks with the
IPC627E Box PC, the IPC677E Panel PC, and the IPC647E
and IPC847E Rack PCs
• Can also be used on the IPC427E, IPC627D and
IPC827D Box PCs, the IPC477E and IPC677D Panel PCs,
and the IPC647D and IPC847D Rack PCs
• Execution of functions and algorithms implemented with
high-level languages under Windows (C/C++, C#, VB) and
locally in the CPU 1508S (C/C++)
• Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes as well as synchronous
operation, support for external encoders, precise position
gearing between axes, output cams/cam tracks and probes
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1508S
■ Technical specifications
Article number 6ES7672-8AC01-0YA0 Article number 6ES7672-8AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1508S CPU 1508S
General information PROFINET IO Controller
Product type designation CPU 1508S Services
Engineering with - Isochronous mode Yes
• STEP 7 TIA Portal configurable/ V16 with HSP 287 - Direct data exchange Yes; Requirement: IRT and
integrated from version isochronous mode (MRPD optional)
Memory - shortest clock pulse 500 µs
Work memory - IRT Yes
• integrated (for program) 10 Mbyte - PROFIenergy Yes
• integrated (for data) 100 Mbyte - Prioritized startup Yes; max. 32 PROFINET devices;
• integrated (for CPU function library 50 Mbyte if you want to use the "Prioritized
of CPU Runtime) startup" functionality in STEP7 for
the PROFINET interface of the CPU,
Load memory the CPU and the device must be
• integrated (on PC mass storage) 1 024 Mbyte seperated by means of a switch
(e.g SCALANCE X205) or CP1625
CPU processing times
- Number of connectable 256
for bit operations, typ. 1 ns; On IPC427E, IO Devices, max.
Intel Xeon processor
- Of which IO devices with IRT, max. 64
for word operations, typ. 2 ns; On IPC427E,
Intel Xeon processor - Number of connectable 256
IO Devices for RT, max.
for fixed point arithmetic, typ. 2 ns; On IPC427E,
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1508S
■ Technical specifications
Article number 6ES7672-8AC01-0YA0 Article number 6ES7672-8AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1508S CPU 1508S
Protocols PROFIBUS DP master
• PROFINET IO Controller Yes • Number of DP slaves, max. 64
• PROFINET IO Device Yes Services
• SIMATIC communication Yes - Equidistance No
• Open IE communication Yes - Isochronous mode No
• Web server Yes Address area
• Media redundancy No - Inputs, max. 8 kbyte
PROFINET IO Controller - Outputs, max. 8 kbyte
Services 4. Interface
- Isochronous mode No Interface type PROFIBUS with CP 5623
- IRT No Number of connections 44
- PROFIenergy Yes via this interface
- Prioritized startup Yes; max. 32 PROFINET devices; Interface types
if you want to use the "Prioritized • RS 485 Yes
startup" functionality in STEP 7 for Protocols
the PROFINET interface of the CPU,
the CPU and the device must be • PROFIBUS DP master Yes
separated by means of a switch • PROFIBUS DP slave No
(e.g. SCALANCE X205)
• SIMATIC communication Yes; no PG/STEP 7 connection
8 - Number of connectable
IO Devices for RT, max.
128
PROFIBUS DP master
possible
Software Controllers
SIMATIC S7-1500 Software Controllers
Standard CPUs
CPU 1508S
■ Technical specifications
Article number 6ES7672-8AC01-0YA0 Article number 6ES7672-8AC01-0YA0
SIMATIC Software Controller SIMATIC Software Controller
CPU 1508S CPU 1508S
Supported technology objects Operating systems
Motion Control Yes; Note: The number of technology Runs under operating system
objects affects the cycle time of the • Windows 7 Yes; Professional, Enterprise,
PLC program; selection guide via the Ultimate (32 bit and 64 bit);
TIA Selection Tool or SIZER Windows Embedded Standard 7 with
• Number of available Motion Control 4 800 delivery image of the SIMATIC IPC
resources for technology objects • Windows 10 Yes; Windows 10 Enterprise 2016
• Required Motion Control resources LTSB, 64-bit, MUI on IPC2x7E,
- per speed-controlled axis 40 IPC4x7E, IPC6x7D, IPC8x7D;
Windows 10 Enterprise 2019 LTSC
- per positioning axis 80 64-bit, MUI on IPC2x7E, IPC4x7E,
- per synchronous axis 160 IPC6x7E, IPC8x7E
- per external encoder 80 Configuration
- per output cam 20 Programming
- per cam track 160 Programming language
- per probe 40 - LAD Yes
Controller - FBD Yes
• PID_Compact Yes; Universal PID controller with - STL Yes
integrated optimization - SCL Yes
• PID_3Step Yes; PID controller with integrated - CFC No
• PID-Temp
optimization for valves
Yes; PID controller with integrated
- GRAPH
Know-how protection
Yes 8
optimization for temperature
Counting and measuring • User program protection/ Yes
password protection
• High-speed counter Yes
• Copy protection Yes
Hardware requirement
• Block protection Yes
Hardware required SIMATIC IPC4x7E, IPC6x7D/E,
IPC8x7D/E Access protection
Processor • Protection level: Write protection Yes
• Single-core processor No • Protection level: Yes
Read/write protection
• Single-core processor No
with hyper-threading • Protection level: Yes
Complete protection
• Multi-core processor Yes
Open Development interfaces
• Multi-core processor Yes
with hyper-threading • Size of ODK SO file, max. 9.8 Mbyte
• occupied cores 1; For multicore processors
with activated Hyper-Threading,
one complete physical core is
reserved for the CPU 1507S
Memory
• Work memory, min. 8 Gbyte
• Hard disk memory required 720 Mbyte
for installation
• Temporary hard disk memory 230 Mbyte
for installation
• Hard disk memory required 1 000 Mbyte
at runtime
Software Controllers
SIMATIC S7-1500 Software Controllers
Fail-safe CPUs
CPU 1507S F
■ Overview
• Supports PROFIsafe in distributed configurations
• Optimized for PC-based control tasks with the
IPC427E Microbox PC and the IPC477E Panel PC
(requires configuration with NVRAM)
• Can also be used on IPC227E, IPC627D, IPC627E
and IPC827D Box PCs, IPC277E, IPC677D and
IPC677E Panel PCs, and IPC647E and IPC847E Rack PCs
(configurations with NVRAM are required for the IPC227E,
IPC427E, IPC627D, IPC827D, IPC277E, IPC477E and
IPC677D PCs)
• Execution of functions and algorithms implemented with
high-level languages under Windows (C/C++, C#, VB) and
locally in the CPU 1507S F (C/C++)
• Integrated Motion Control functionalities for controlling
speed-controlled and positioning axes as well as synchronous
operation, support for external encoders, precise position
gearing between axes, output cams/cam tracks and probes
• Integrated web server for diagnostics with the option of
• Software Controller for implementing the functions of a creating user-defined web pages
SIMATIC S7-1500 Controller on a SIMATIC IPC • OPC UA server (data access) and client as runtime option
• For use as a PC-based PLC in machines with distributed I/O for easy connection of the software controller to Windows
via PROFINET and PROFIBUS applications or non-Siemens devices/systems
8 • For utilizing IPC onboard interfaces and PC plug-in cards
for PROFINET and PROFIBUS connections
• Can be used for safety functions up to SIL 3 according to
IEC 61508 and up to PL e according to ISO 13849
Software Controllers
SIMATIC S7-1500 Software Controllers
Fail-safe CPUs
CPU 1507S F
■ Technical specifications
Article number 6ES7672-7FC01-0YA0 Article number 6ES7672-7FC01-0YA0
SIMATIC Failsafe SW Ctrl SIMATIC Failsafe SW Ctrl
CPU 1507S F CPU 1507S F
General information Protocols
Product type designation CPU 1507S F • PROFINET IO Controller Yes
Engineering with • PROFINET IO Device Yes
• STEP 7 TIA Portal configurable/ V16 with HSP 287 • SIMATIC communication Yes
integrated from version • Open IE communication Yes
Memory • Web server Yes
Work memory PROFINET IO Controller
• integrated (for program) 7.5 Mbyte Services
• integrated (for data) 20 Mbyte - Isochronous mode Yes
• integrated (for CPU function library 50 Mbyte - Direct data exchange Yes; Requirement: IRT and
of CPU Runtime) isochronous mode (MRPD optional)
Load memory - shortest clock pulse 500 µs
• integrated (on PC mass storage) 320 Mbyte - IRT Yes
CPU processing times - PROFIenergy Yes
for bit operations, typ. 1 ns; On IPC427E, - Prioritized startup Yes; max. 32 PROFINET devices;
Intel Xeon processor if you want to use the "Prioritized
for word operations, typ. 2 ns; On IPC427E, startup" functionality in STEP7 for
Intel Xeon processor the PROFINET interface of the CPU,
for fixed point arithmetic, typ. 2 ns; On IPC427E, the CPU and the device must be
Software Controllers
SIMATIC S7-1500 Software Controllers
Fail-safe CPUs
CPU 1507S F
■ Technical specifications
Article number 6ES7672-7FC01-0YA0 Article number 6ES7672-7FC01-0YA0
SIMATIC Failsafe SW Ctrl SIMATIC Failsafe SW Ctrl
CPU 1507S F CPU 1507S F
2. Interface 3. Interface
Interface type Onboard PROFINET / IE interface Interface type PROFIBUS with CP 5622,
X2/X3 of the SIMATIC IPC, CP 5622 onboard
Intel Springville i210T Number of connections 44
Number of connections 128 via this interface
via this interface Interface types
Interface types • RS 485 Yes
• RJ 45 (Ethernet) Yes Protocols
- Transmission rate, max. 100 Mbit/s • PROFIBUS DP master Yes
- Industrial Ethernet status LED Yes • PROFIBUS DP slave No
• Number of ports 1 • SIMATIC communication Yes; no PG/STEP 7 connection
• integrated switch No possible
Protocols PROFIBUS DP master
• PROFINET IO Controller Yes • Number of DP slaves, max. 64
• PROFINET IO Device Yes Services
• SIMATIC communication Yes - Equidistance No
• Open IE communication Yes - Isochronous mode No
• Web server Yes Address area
8 • Media redundancy
PROFINET IO Controller
No - Inputs, max.
- Outputs, max.
8 kbyte
8 kbyte
Services 4. Interface
- Isochronous mode No Interface type PROFIBUS with CP 5623
- IRT No Number of connections 44
- PROFIenergy Yes via this interface
- Prioritized startup Yes; max. 32 PROFINET devices; Interface types
if you want to use the "Prioritized • RS 485 Yes
startup" functionality in STEP 7 for Protocols
the PROFINET interface of the CPU,
the CPU and the device must be • PROFIBUS DP master Yes
separated by means of a switch • PROFIBUS DP slave No
(e.g. SCALANCE X205)
• SIMATIC communication Yes; no PG/STEP 7 connection
- Number of connectable 128 possible
IO Devices for RT, max.
PROFIBUS DP master
- of which in line, max. 128
• Number of DP slaves, max. 125
- Number of IO Devices that can 8
be simultaneously activated/ Protocols
deactivated, max. Number of connections
- Number of IO Devices per tool, 8 • Number of connections, max. 128
max.
Redundancy mode
- Updating times The minimum value of the
Media redundancy
update time also depends on
communication share set for - MRP Yes
PROFINET IO, on the number of - MRPD Yes; Requirement: IRT
IO devices, and on the quantity of
configured user data - Switchover time on line break, typ. 200 ms; For MRP,
bumpless for MRPD
Address area
- Number of stations in the ring, 50
- Inputs, max. 8 kbyte max.
- Outputs, max. 8 kbyte SIMATIC communication
PROFINET IO Device • S7 routing Yes
Services OPC UA
- Isochronous mode No • OPC UA Client Yes; Data access (read, write),
- IRT No method call
- PROFIenergy Yes • OPC UA Server Yes; Data access
(read, write, subscribe), method call,
- Shared device Yes
custom address space
- Number of IO Controllers with 4
shared device, max.
- Asset management record Yes
Software Controllers
SIMATIC S7-1500 Software Controllers
Fail-safe CPUs
CPU 1507S F
■ Technical specifications
Article number 6ES7672-7FC01-0YA0 Article number 6ES7672-7FC01-0YA0
SIMATIC Failsafe SW Ctrl SIMATIC Failsafe SW Ctrl
CPU 1507S F CPU 1507S F
Supported technology objects Memory
Motion Control Yes; Note: The number of technology • Work memory, min. 4 Gbyte
objects affects the cycle time of the • Hard disk memory required 720 Mbyte
PLC program; selection guide via the for installation
TIA Selection Tool or SIZER
• Temporary hard disk memory 230 Mbyte
• Number of available Motion Control 4 800 for installation
resources for technology objects
• Hard disk memory required 400 Mbyte
• Required Motion Control resources at runtime
- per speed-controlled axis 40 Operating systems
- per positioning axis 80 Runs under operating system
- per synchronous axis 160 • Windows 7 Yes; Professional, Enterprise,
- per external encoder 80 Ultimate (32 bit and 64 bit);
- per output cam 20 Windows Embedded Standard 7 with
delivery image of the SIMATIC IPC
- per cam track 160
• Windows 10 Yes; Windows 10 Enterprise 2016
- per probe 40 LTSB, 64-bit, MUI on IPC2x7E,
Controller IPC4x7E, IPC6x7D, IPC8x7D;
Windows 10 Enterprise 2019 LTSC
• PID_Compact Yes; Universal PID controller with 64-bit, MUI on IPC2x7E, IPC4x7E,
integrated optimization IPC6x7E, IPC8x7E
• PID_3Step Yes; PID controller with integrated Configuration
• PID-Temp
optimization for valves
Yes; PID controller with integrated
Programming 8
optimization for temperature Programming language
Counting and measuring - LAD Yes; incl. failsafe
• High-speed counter Yes - FBD Yes; incl. failsafe
Standards, approvals, certificates - STL Yes
Highest safety class achievable - SCL Yes
in safety mode - CFC No
• Performance level according to PLe - GRAPH Yes
ISO 13849-1
Know-how protection
• SIL acc. to IEC 61508 SIL 3
• User program protection/ Yes
Probability of failure password protection
(for service life of 20 years and
repair time of 100 hours) • Copy protection Yes
- Low demand mode: < 2.00E-05 • Block protection Yes
PFDavg in accordance with SIL3 Access protection
- High demand/continuous mode: < 1.00E-09 • Protection level: Write protection Yes
PFH in accordance with SIL3 • Protection level: Yes
Hardware requirement Read/write protection
Hardware required SIMATIC IPC2x7E, IPC4x7D/E, • Protection level: Yes
IPC627D, IPC677D, IPC827D: Write protection for Failsafe
configurations with NVRAM required; • Protection level: Yes
IPC6x7E, IPC8x7E Complete protection
Processor Open Development interfaces
• Single-core processor No • Size of ODK SO file, max. 9.8 Mbyte
• Single-core processor No
with hyper-threading
• Multi-core processor Yes
• Multi-core processor Yes
with hyper-threading
• occupied cores 1; For multicore processors with
activated Hyper-