Operating Instructions For The Interface Converter FB's Serial-TCP 1109-03 Furness
Operating Instructions For The Interface Converter FB's Serial-TCP 1109-03 Furness
Operating Instructions For The Interface Converter FB's Serial-TCP 1109-03 Furness
Seite 1 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
CONTENTS
1. VERSIONLIST OF INSTRUCTIONS 3
2. BASIC INSTRUCTIONS 4
4. FUNCTION BLOCKS 5
5. CONTROL BLOCKS 9
Seite 2 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
1. Versionlist of instructions
Seite 3 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
2. Basic Instructions
This manual is intended exclusively for technicians trained in control and automation
technology, who have experience in installing, commissioning, programming and
performing diagnostics on Siemens Step7.
Any other use will not comply with the requirements. For any resulting damage
Industrialsoft GmbH & Co KG is not liable.
2.3 Copyright
The copyright to this manual and the supplied software remains the property of
Industrialsoft GmbH & Co KG.
The delivered software must be used only in by us installed and licensed facilities.
The manual is intended solely for the owners of the facilities and operators.
Seite 4 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
3. TCP Installation
TCP
Notice:
TCP_Communication_with_CP343.doc
TCP_Communication_with_TConn.doc
4. Function Blocks
The function blocks (FB) described serves for controlling and parametrizing Furness
devices via PROFIBUS-DP in a SIMATIC-S7 controller with integrated DP master
module (e.g. CPU315-2DP). With the blocks the many functions of the Furness
device can be comfortably incorporated in the program. The blocks can be
parametrized and are capable of many instances. They are linked into the user
program for each device from where they can be accessed cyclically with a separate
instance data block or multi-instance block. Simultaneous use of other function
blocks for controlling the same device is not permitted. If additional commercially
available components such as sensors and actuators are connected, the specified
limits for pressures, temperatures, electrical data, etc. must not be exceeded. Note
also the Siemens specifications regarding the use of their PLC SIMATIC S7.
Seite 5 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
Please note that it is not possible with the present state of technology to create pro-
grammed software which functions without problems and is compatible with all
applications and combinations intended by the user.
As a rule the software must therefore be used in the designated manner as specified
in the program description and in the user instructions. At the moment when the
software is transferred or made available, it is in a state in which it will function under
normal operating and application conditions.
Industrialsoft Gmbh & CoKG does not guarantee that the software will suffice for all
applications and purposes intended by the user, or that it will function without
problems when used with other programs, or that it is compatible with these
programs. The responsibility for the correct selection and the consequences of using
the software within the scope of use defined by the user, as well as for the intended
and achieved results therefore lies with the user. The same applies to the written
material supplied with the software. The use of the programmed software does not
exempt you as customer from your duties and responsibility for observing and
adhering to technical machine and safety regulations as well as for a comprehensive
functional check.
This manual contains information on the S7 blocks for Furness device. The following
manual is also required for understanding the function blocks:
This manual on the S7 blocks contains all necessary information for commissioning
the blocks. In addition, the most important extracts from the manual product are also
reproduced. However this does not replace in any way the manual for Furness
product manual. The guidelines and safety regulations listed therein must be
observed at all costs in order to guarantee correct and reliable functioning.
Siemens: When reference is made in this manual to documents from Siemens, this
always means the Step 7 version 5.5 (service pack 2). Other versions of Step 7 may
differ from that described in this manual.
Seite 6 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
With the blocks you can incorporate the functions of the Furness device directly in
your programs. Normally you will require two blocks for the various functions. The
blocks have been purposely split into groups, so that you can decide yourself which
functions you require for your application. The example project contains the following
special blocks:
The following user defined types (UDT) include all Parameter to control the Furness
device.
Seite 7 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
Seite 8 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
5. Control blocks
5.1 Function block “FURNESS_CP_WRITE“
Seite 9 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
Add the Furness UDT's in your device data block (DB). To see all the parameters of the
UDT's, turn the Ctrl + 4 key combination to change to the data view.
Controlbits + tags:
Enable to control a bit to the
device. Select the device_id and
the program number.
Statusbits + tags:
Actual statusbits and values
Result status:
Actual result of the current test
and results of 2 result steps.
Seite 10 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
To select a program number in the unit, set the instrument ID and the new program number to
the control parameters, and then click to select the bit "Change_Program"
If the communication was successful, the new program number is displayed in the status
parameters.
Seite 11 / 12
Instructions Furness TCP Industrialsoft GmbH & Co KG
Projectno.: 1109-03_DP-Seriell Im Kirchfeld 14
58802 Balve
5.6 Troubleshooting