Maple: Plumbing General Notes Plumbing Fixture Specifications and Connection Schedule
Maple: Plumbing General Notes Plumbing Fixture Specifications and Connection Schedule
Maple: Plumbing General Notes Plumbing Fixture Specifications and Connection Schedule
P-01
WH WATER HEATER
WHD WALL HYDRANT
FIRE RATING LEGEND
2-HR WALL
*2ND FLR CEIL. IS 2-HR RATED
STRAINER FLASHING COLLAR
TOP OF QUARRY TILE 1" HW DN TO BLW
FLUSH WITH TOP OF
DRAIN GRATE
GRATE - SEE FIXTURE GREEN | URBAN | SMART ARCHITECTURE
SCHEDULE FOR TYPE 19 WEST HARGETT STREET #700
DRAIN LINE, FINISHED
RALEIGH, NORTH CAROLINA 27601
AIR GAP SUPPORT ABV HUB FLOOR www.aoarchitect.com
DOME STRAINER
HUB OFFICE
ADAPTER WH-1 202
FLOOR
6" MIN.
SEEPAGE HOLES
TO DRAIN
maple
ENGINEERING, pllc
1405 HILLSBOROUGH ST
RALEIGH, NC 27605 LIC.#: P-0990
P:919-341-4247 F:919-890-3797
SEE FLOOR PLAN plumbing mechanical electrical
DEEP SEAL FOR PIPE SIZE STORAGE
TRAP 204 PROJECT No.:
1301
HUB DRAIN DETAIL FLOOR DRAIN DETAIL FLOOR SINK DETAIL
7 NO SCALE 6 NO SCALE 5 NO SCALE
LOUNGE
201
CONFERENCE
203
VACUUM
BREAKER
H.W. TO FIXTURES
SHUT-OFF
VALVE EXPANSION TANK
TEST TEE
(APPX. 18" AFF) GENERAL NOTES - THIS SHEET TAGGED NOTES - THIS SHEET
WATER
HEATER
1. ITEMS SHOWN IN FAINT ARE EXISTING TO REMAIN. NEW OR 1 CLEARLY LABEL ALL PORTIONS OF CW LINE UPSTREAM
FINISHED RELOCATED ITEMS ARE SHOWN IN BOLD. SEE LEGEND. OF BFP "DO NOT TAP".
WALL 1-1/2" DEEP GALV. 2. P.C. TO FIELD VERIFY EXACT SIZE, INVERT, DIRECTION AND 2 PROVIDE TEMPERING VALVE, TV-1, UNDER SINK. SET TO
DRAIN PAN LOCATION OF ALL EXISTING LINES BEFORE BEGINNING
HB
FLOOR WORK.
3 PORTION OF BRANCH LINE IS PART OF CIRCUIT VENT
3. P.C. TO VERIFY THAT NO FIXTURES ARE CONNECTED
SYSTEM, MAXIMUM SLOPE 8%. TURN DOWN AS
1" DRAIN LINE UPSTREAM OF BACK FLOW PREVENTER (RPZ).
NECESSARY AFTER MOST DOWNSTREAM FIXTURE. IF
NOTE: TO MOP SINK SLOPE REQ'S CANNOT BE MAINTAINED ADDITIONAL
TO DRAIN
1. INSTALL WATER HEATER PER MANUFACTURER REQUIREMENTS VENTS WILL BE REQUIRED.
NOTE: 2. PROVIDE HEAT TRAP ON CW AND HW LINES PER ENERGY CODE
EXTEND TEST TEE OPENING IF PLUG IS GREATER THAN
8" FROM FINISHED WALL. 1" CW UP TO WH-1
104
DISH
3"FS
103
(IN.)
(IN.)
(IN)
(IN)
EXIST. P5 2
4" TO P-1 P-1 EXIST.
ITEM GREASE P-3 4" GW SEALS:
# QTY. EQUIPMENT PLUMBING NOTES TRAP 2"HD P-2 CW DOWN
IN WALL
VENT
GW
E2 1 ESPRESSO MACHINE - 0.5 0.5 - W/ CV-1 & SHOCK ARRESTOR. VENT
GW
E10
E3 1 COFFEE MACHINE - 0.5 - - W/ CV-1 & SHOCK ARRESTOR. EXIST. 2
EXIST.
E10 1 ICE MAKER - 0.5 0.5 - W/ CV-1 & SHOCK ARRESTOR. 4" TO
E3 AAV 4" SS
S.S. DINING
E20 1 TEA MAKER - 0.5 - - W/ CV-1 & SHOCK ARRESTOR.
2"HD 3"FS
E23 1 ICE BIN - - 1.0 - DRAIN TO HUB DRAIN 106
NOTE: E23 P2 E20 P3
P1 1 3 COMPARTMENT SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK. CW UP
P.C. TO VERIFY EXISTING 2
GW
P2 1 HAND SINK 0.5 0.5 - 1.5 W/ TV-1 P11 FR SLAB
LINES. P.C. TO TAKE ALL 4/21/13
P3 1 HOT WATER DISPENSER - 0.5 - - W/ CV-1 & SHOCK ARRESTOR. MEASURES POSSIBLE TO BAR 1/2" CW
ENSURE GREASY WASTE 3"FD
P4 1 COLD WATER RINSE - 0.5 0.5 - DRAIN TO HUB DRAIN. 102 UNDER FLR
AND SANITARY SEWER
GW
P5 1 1 COMPARTMENT SINK 0.5 0.5 1.5 - DRAIN TO FLOOR SINK. SYSTEMS DO NOT BECOME
P6 1 HAND SINK 0.5 0.5 - 1.5 W/ TV-1 INTERCONNECTED. P.C.
P11 1 WATER STATION - 0.5 - 1.5 DRAIN TO FLOOR SINK. RESPONSIBLE FOR ANY 2"HD E2
INTERCONNECTION THAT
NOTE: OCCURS. P4 wco
1. SCHEDULE INFO TAKEN FROM KITCHEN SUPPLIER PLANS/INFO. P.C. TO VERIFY BEFORE BEGINNING CW UP
WORK. P.C. TO VERIFY EXACT SIZE, QTY AND LOCATION OF CONNECTIONS TO ALL EQUIPMENT. FR SLAB
AAV
PROVIDE ALL NECESSARY REDUCERS, FILTERS AND OTHER ACCESSORIES.
ISSUE: PERMIT SET
ENTRY DATE: 4/21/13
101 DRAWN BY: CLR/JMS/RSA
REVISIONS:
BV-1
P-02
GREEN | URBAN | SMART ARCHITECTURE
maple
ENGINEERING, pllc
1405 HILLSBOROUGH ST
RALEIGH, NC 27605 LIC.#: P-0990
P:919-341-4247 F:919-890-3797
plumbing mechanical electrical
PROJECT No.:
1301
SEALS:
4/21/13
NOTE:
P.C. TO VERIFY EXISTING
LINES. P.C. TO TAKE ALL
MEASURES POSSIBLE TO
ENSURE GREASY WASTE
AND SANITARY SEWER
SYSTEMS DO NOT BECOME ISSUE: PERMIT SET
INTERCONNECTED. P.C. DATE: 4/21/13
RESPONSIBLE FOR ANY DRAWN BY: CLR/JMS/RSA
INTERCONNECTION THAT
OCCURS. REVISIONS:
PLUMBING
RISERS
P-03
FIRE RATING LEGEND
2-HR WALL
*2ND FLR CEIL. IS 2-HR RATED
BASED UPON CHAPTER 4 OF THE 2012 NORTH CAROLINA FUEL GAS CODE, EQUIPMENT SCHEDULE
LESS THAN 2.0 PSI INLET PRESSURE, 0.5" WC PRESSURE DROP.
NOTE:
P.C. TO CONFIRM ABOVE INFORMATION AND LOCATION, LOUNGE
SIZE, QUANTITY AND TYPE OF ALL GAS CONNECTIONS W/ 201
ACTUAL EQUIPMENT BEFORE BEGINNING WORK.
CONFERENCE
GAS REGULATOR
TEST PORT
W/ PLUG
NOTE:
GENERAL NOTES - THIS SHEET MENS
TEST PORT TO BE NOT LESS THAN
105
10 PIPE DIAMETERS FROM 1. P.C. IS TO PROVIDE REGULATOR, FLEX CONNECTION &
DISCHARGE OF GAS
SHUT-OFF VALVE AT EACH EQUIPMENT CONNECTION.
REGULATOR.
COORDINATE AND VERIFY EXACT SIZE AND LOCATION OF DISH
EQUIPMENT GAS CONNECTION(S) BEFORE BEGINNING
103
WORK.
2. PROVIDE LABELING ON GAS PIPING AS REQUIRED BY 2012
WOMENS
NCFGC SEC. 401.5 & 401.7.
3. P.C. IS RESPONSIBLE FOR VENTING REGULATORS TO 104
EXTERIOR AS REQ'D. SEALS:
4. P.C. TO FIELD VERIFY EXACT, SIZE, LOCATION AND
ROUTING OF ALL EXISTING GAS PIPING BEFORE
GAS CONNECTION DETAIL BEGINNING WORK.
4 NO SCALE
DINING
106
4/21/13
BAR
NOTE: E1 102
VERIFY EXACT METER (30 MBH)
LOCATION W/ EXISTING
CONDITIONS AND
LANDLORD BEFORE
BEGINNING WORK.
SEE PLAN
SUITE SUITE SUITE SUITE SUITE
56 50 46 40 36
NORTH
P-04
HVAC GENERAL NOTES SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE
AIR HANDLING UNIT DATA HEAT PUMP
FAN DATA COOLING HEAT AUX. ELECTRICAL DATA GENERAL DATA ELECTRICAL DATA
I. GENERAL REQUIREMENTS: III. MATERIALS: GREEN | URBAN | SMART ARCHITECTURE
UNIT AREA MANUF. FAN ESP MOTOR OA TOTAL SENS. TOTAL HEAT VOLTAGE MCA MOCP UNIT MANUF. EFF. VOLTAGE MCA MOCP
TONNAGE NOTES 19 WEST HARGETT STREET #700
1. MECHANICAL CONTRACTOR IS TO FURNISH AND PAY FOR ALL LABOR, MATERIAL, 1. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE SHOWN OR SPECIFIED. TAG SERVED MODEL CFM (" OF WG) (HP) (CFM) (MBH) (MBH) (MBH) (KW@208) (V/PH) (A) (A) TAG MODEL (SEER) (V/PH) (A) (A)
RALEIGH, NORTH CAROLINA 27601
EQUIPMENT, PERMITS & FEES REQUIRED FOR THE COMPLETE INSTALLATION OF ALL TRANE TRANE www.aoarchitect.com
SYSTEMS IN THIS SECTION OF WORK. 2. ALL MATERIALS INSTALLED IN RETURN PLENUM ARE TO BE PLENUM RATED. AH-1 1ST FLOOR 2000 0.55" 1.0 275 60.0 48.0 60.0 11.5 39.7 50 HP-1 5.0 (15.0) 34.0 60 1,2,3,4,5,6,7,8,9,10,11
GAT2A0C60 4TTR5060
2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH NC MECHANICAL CODES 3. PROVIDE HANGERS & SUPPORTS APPROVED FOR USE BY 2012 NC MECHANICAL TRANE TRANE (15.0)
AH-2 2ND FLOOR 2000 0.50" 1.0 250 60.0 48.0 60.0 11.5 39.7 50 HP-2 5.0 34.0 60 1,2,3,4,5,6,7,8,9,10,11
GAT2A0C60 4TTR5060
AND ALL OTHER APPLICABLE CODES. MC IS TO COORDINATE W/ G.C. IN REGARDS CODE.
TO PROJECT TIMELINE, WORK HOURS, AS WELL AS ANY BONDING OR INSURANCE
NOTES:
REQUIREMENTS. 4. ALL MAIN DUCTWORK (SUPPLY, RETURN, EXHAUST, OUTSIDE AIR) SHALL BE
GALVANIZED SHEET METAL CONSTRUCTED IN ACCORDANCE WITH SMACNA 1. 8. AHU TO USE HORIZONTAL APPLICATION.
3. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED COMPLETE WITH ALL STANDARDS. RUNOUTS FROM MAIN/BRANCH DUCTS MAY BE FLEXIBLE DUCT
9. RUN CONDENSATE TO AREA STORM DRAIN PIPING. PROVIDE CONDENSATE PUMP AS NECESSARY.
ACCESSORIES, HANGERS, SUPPORTS, CONTROLS, ETC FOR A FULLY FUNCTIONING
SYSTEM REGARDLESS OF PRESENCE ON PLANS.
CONFORMING TO THE REQUIREMENTS OF UL 181 FOR CLASS 1 FLEXIBLE AIR DUCTS.
MAX. LENGTH OF FLEX PER RUNOUT TO BE 6'-0" UNLESS SHOWN OTHERWISE.
ACCORDANCE WITH ARI STANDARD 340.
10.
maple
ENGINEERING, pllc
2. REFRIG. PIPING TO BE SIZED PER TOTAL INSTALL. EQUIV. LENGTH. LONG-LINE APP.TO BE PROVIDED WHENEVER MFG. RECOMM.
1405 HILLSBOROUGH ST
LENGTHS ARE EXCEEDED, INCL. LIQ. LINE SOLENOID VALVES, ACCUMULATOR, ETC. MAX T.E.L. IS PER MFG. EMERGENCY HEAT OVERRIDE OPTION. RALEIGH, NC 27605 LIC.#: P-0990
4. ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE GUARANTEED TO BE FREE 5. NO FLEXIBLE DUCT ALLOWED FOR NEGATIVE PRESSURE EXHAUST APPLICATIONS. P:919-341-4247 F:919-890-3797
OF DEFECTS FOR A PERIOD OF ONE (1) YEAR AFTER FINAL ACCEPTANCE OF WORK 11. CYCLE PROTECTOR AND TIME DELAY RELAY (IF AVAILABLE). plumbing mechanical electrical
6. ALL SUPPLY AND RETURN DUCTWORK AND PLENUMS SHALL BE INSULATED. 3. PROVIDE SINGLE POINT ELECTRICAL CONNECTION FOR AIR HANDLING UNIT.
OR IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD GUARANTEE, IF NOTE:
LONGER. ALL COMPRESSORS ARE TO INCLUDE FIVE (5) YEAR WARRANTY. EXISTING INSULATION OF DUCTWORK IN UNCONDITIONED SPACE SHALL BE MINIMUM R-5 PER PROJECT No.:
EQUIPMENT IS EXCLUDED FROM WARRANTY REQUIREMENT. 2012 NCECC. INSULATION OF DUCTWORK OUTSIDE BUILDING THERMAL ENVELOPE
4. PROVIDE 3 SETS OF NEW FILTERS FOR EACH UNIT. PROVIDE ONE AT INSTALLATION, ONE PRIOR TO AIR BALANCE
AND ONE AT TURNOVER TO OWNER.
COORDINATE W/ G.C.
AND OWNER REGARDING 1301
(I.E. ROOF, ATTIC, CRAWLSPACE) SPACE SHALL BE MINIMUM R-8 PER 2012 NCECC. POSSIBLE RE-USE OF
5. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND 5. OUTDOOR UNITS SHALL HAVE A MINIMUM 15.0 SEER RATING. EXISTING HEAT PUMPS ON
ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE 7. CONCEALED SHEET METAL SUPPLY & RETURN DUCT MAY BE EXTERNALLY INSULATED ROOF AND/OR USE OF
6. PROVIDE MANUFACTURER'S 7 DAY PROGRAMMABLE THERMOSTAT W/ MANUAL OVERRIDE.
FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL WITH MINERAL FIBER BOARD OR BLANKET OR MAY BE INTERNALLY INSULATED WITH EXISTING REFRIGERANT
PERMIT. ACOUSTICAL DUCT LINER. EXPOSED SPIRAL DUCTWORK DOES NOT REQUIRE 7. PROVIDE BI-FLOW TXV FOR HEAT PUMP OPERATION. LINES.
INSULATION UNLESS OTHERWISE NOTED (WHEN INSTALLED IN CONDITIONED SPACE).
6. DO NO SCALE DRAWINGS FOR MEASUREMENT.
6. ALL REFRIGERANT PIPING SHALL BE INSTALLED PER MFG'S INSTRUCTIONS IN REGARDS ENERGY REQUIREMENTS:
TO SUPPORTS, BENDS, FITTINGS, OIL TRAPS, ETC. MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT SEALS:
7. PENETRATIONS OF NON-RATED WALLS, PARTITIONS AND FLOOR OF COMBUSTIBLE METHOD OF COMPLIANCE
CONSTRUCTION SHALL BE FIRESTOPPED WITH MATERIALS EQUIVALENT TO TWO
INCHES OF WOOD. FIRESTOPPING SHALL COMPLY WITH ASTM E-814.
PRESCRIPTIVE ENERGY COST BUDGET
8. ANY NOTCHING, DRILLING, BORING OR OTHER ALTERATION TO BUILDING
THERMAL ZONE 4A
STRUCTURE SHALL BE PERFORMED IN A CODE APPROVED METHOD AND NOT
THREATEN THE INTEGRITY OF THE BUILDING STRUCTURE. EXTERIOR DESIGN CONDITIONS
WINTER DRY BULB 14
9. SUPPORT ALL DUCTWORK AND PIPING IN ACCORDANCE W/ 2012 NC MECHANICAL SUMMER DRY BULB 93
CODE. ANY SUSPENDED MATERIALS SHALL BE DIRECTLY SUPPORTED BY THE BUILDING 4/21/13
STRUCTURE. INTERIOR DESIGN CONDITIONS
WINTER DRY BULB 70
10. PENETRATIONS OF ALL EXTERIOR WALLS, FLOORS AND CEILINGS SHALL BE SEALED IN SUMMER DRY BULB 76
AN AIR TIGHT MANNER AND IN ACCORDANCE W/ 2012 NCECC APPENDIX 2 RELATIVE HUMIDITY 50%
DETAILS. ALL PENETRATIONS OF WALLS, FLOORS & CEILINGS IN RETURN OR EXHAUST BLDG 1
PLENUMS SHALL BE SEALED IN AN AIR TIGHT MANNER.
BUILDING HEATING LOAD (MBH) 75.2
11. DUCT ACCESS DOORS TO BE PROVIDED AT ALL FIRE, RADIATION & SMOKE
DAMPERS, SMOKE DETECTORS, CLEANOUTS AND ANY OTHER CODE REQUIRED BUILDING COOLING LOAD (MBH) 110.5
LOCATIONS.
MECHANICAL SPACING CONDITIONING SYSTEM
UNITARY ISSUE: PERMIT SET
12. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL
DESCRIPTION OF UNIT (2) 5-TON SS HP DATE: 4/21/13
MECHANICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION
HEATING EFFICIENCY SEE SCHEDULES DRAWN BY: CLR/JMS/RSA
(PAINT, SPACKLE, ETC.). UPON COMPLETION OF WORK THE MECHANICAL COOLING EFFICIENCY SEE SCHEDULES
CONTRACTOR SHALL CLEAN, WASH, ETC ALL ITEMS AND EQUIPMENT WITHIN HIS HEAT OUTPUT OF UNIT SEE SCHEDULES
SCOPE OF WORK AND LEAVE ALL ITEMS BRIGHT AND CLEAN. REVISIONS:
COOLING OUTPUT OF UNIT SEE SCHEDULES
BOILER
TOTAL BOILER OUTPUT NA
CHILLER
TOTAL CHILLER OUTPUT NA
DESIGNER'S STATEMENT:
TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING
COMPLIES WITH THE MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT
REQUIREMENTS OF THE N.C.S. ENERGY CODE.
SIGNED: MECHANICAL
SCHEDULES & NOTES
NAME: ZACK L. TOMLIN, PE
14x16
8x6
A 180 20x14
10 A 12x6
300
OFFICE 20x14 DN
12x12
TO BELOW
20x14
203
18x16
6x6
150 A
maple
ENGINEERING, pllc
1405 HILLSBOROUGH ST
RALEIGH, NC 27605 LIC.#: P-0990
P:919-341-4247 F:919-890-3797
1 plumbing mechanical electrical
AH-2
STORAGE PROJECT No.:
1301
AH-1
12x12
202
12x12
1 2
2
10x8 A 12x6
20x16
300 3
3 LOUNGE
WL 5028
20x16
System No. W-L-5028 201 6x6
24x16 B
F Ratings - 1 and 2 Hr (See Item 1) 1 1750 150 A
(AH-1)
10x10
12x6 A
300
1A
10x10
1B
A
12x6 A
4 320
3
2
12x12
10x10
10x10
8
5 7
1 3
4" DOOR UNDERCUT.
SECTION A-A SUSPENDED AIR HANDLER. SEE DETAIL. PUMP
2
CONDENSATE TO AREA STORM DRAIN. PROVIDE
BACKWATER VALVE.
3 DUCT MOUNTED SMOKE DETECTOR. SEE DETAIL.
specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following 4
construction features: EXACT MATERIAL AND INSTALLATION W/ ROASTER
MFG. ENSURE REQUIRED CLEARANCES AND SLOPE
ARE MAINTAINED.
16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC.
5
INSTALL IN ACCORDANCE W/ MFG'S INSTRUCTIONS
fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 7-1/2 in. AND 2012 NCFGC SEC. 503.8. COORDINATE
The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. LOCATION W/ G.C., OWNER AND LANDLORD BEFORE 1 20x12
BEGINNING WORK. 20x14 DN
6 NOT USED. FR ABV
sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used:
7 EXISTING EXHAUST LOUVER. M.C. TO CONFIRM C 10x6
100
1
SOURCE OF ANY EXISTING CONNECTED DUCTWORK.
RE-WORK EXISTING DUCTWORK AS NECESSARY. M.C.
TO ENSURE EXHAUST AND OUTSIDE AIR DUCTS DO NOT 6x6
D 150 8x8
CONNECT TO SAME LOUVER.
20x12
tubing. An annular space of min 0 in. (point contact) to max 1-1/2 in. is required within the firestop system. 8 EXISTING OUTSIDE AIR LOUVER. M.C. TO CONFIRM MENS
SOURCE OF ANY EXISTING CONNECTED DUCTWORK. 105 WOMENS
RE-WORK EXISTING DUCTWORK AS NECESSARY. M.C. DISH
See Plastics+ (QMFZ2) category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube 104 DINING
TO ENSURE EXHAUST AND OUTSIDE AIR DUCTS DO NOT 103 EF-1 C 10x6
50
EF-2
106
insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used. SEALS:
CONNECT TO SAME LOUVER.
The hour T Rating of the firestop system is dependent on the hourly fire rating of the wall assembly in which it is installed, the size and type of
9 BULKHEAD ABOVE BAR. SEE ARCH. PLANS.
through penetrant and the pipe covering thickness, as shown in the table below:
10 REFRIGERANT LINES TO BE ROUTED TO ROOF CHASE IN (AH-2)
NORTH WEST CORNER OF ADJACENT SUITE. FIELD
Wall Assembly Hr Rating Type + Through Penetrant Max Diam In. VERIFY EXACT LOCATION AND ROUTING. 14x12 16x12 18x12
COORDINATE POSSIBLE RE-USE OF EXISTING LINESETS
1 A 4
WITH G.C. AND LANDLORD.
1 A, B, or C 2
2 A 4
D 12x12
400 D 12x12
400 4/21/13
2 A, B, or C 2 BAR
102
LINE SET PENETRATION DETAIL (2 HR, GYPSUM) MECHANICAL PLAN - 1ST FLOOR
3 NO SCALE 1 SCALE: 1/4" = 1'-0"
MECHANICAL
PLAN & DETAILS
M-02
GREEN | URBAN | SMART ARCHITECTURE
maple
ENGINEERING, pllc
1405 HILLSBOROUGH ST
RALEIGH, NC 27605 LIC.#: P-0990
P:919-341-4247 F:919-890-3797
plumbing mechanical electrical
PROJECT No.:
1301
VENTLOCK #603
AIR CLOSED BALL JOINT
FLOW HEM EDGE
PIVOT
LENGTH=W+1/3"W
1/4" SET
SCREW VOLUME DAMPER WITH NOTE:
SLIP SLEEVE SUPPLY AIR DUCT.
LOCK 3/8" LOCKING QUADRANT FLEX DUCT TURN INTO DIFFUSER TO BE REPLACED
BRANCH AND END BEARING. BY INSULATED SHEET METAL ELBOW FOR (3)
DUCT ROUND SHEET (WHERE ACCESIBLE) FARTHEST CEILING DIFFUSERS FROM AIR
METAL DUCT. HANDLER. THERMAFLEX "FLEX FLOW ELBOW"
PULL ROD FLEX DUCT SUPPORT MAY BE USED IN LIEU OF SHEET METAL
DIAMETER "D" ELBOW.
FLOW
AIR
1/4" SET
SCREW LOCK
FINISHED
CEILING SURFACE DIFFUSER/GRILLE
NOTES:
(COORD. FRAME TYPE)
1. SEE FLOOR PLANS AND SPECIFICATIONS
NOTES:
FOR DUCT INSULATION REQUIREMENTS.
1. PROVIDE INSULATED REGISTER BOOT/PLENUM BOX IF NECESSARY.
2. TAP OFF TOP/SIDE/BOTTOM OF DUCT AS REQUIRED 2. RETURN APPLICATION IS SIMILAR. ALL ELBOWS IN RETURN APPLICATION
TO BE INSULATED SHEET METAL (NO FLEX ELBOWS).
SEALS:
ATTACH RODS TO
STRUCTURE,
REFRIGERANT LINES SIZE PER MFG
20 GA. GALVANIZED
JOIST / TRUSS
SHEET METAL HOOD SPRING VIBRATION
LOW VOLTAGE CONTROL WIRE(S)
ISOLATORS. (TYP OF 4)
INSULATED REFRIGERANT LINE SET(S) OUTSIDE AIR DUCT
FILL OPENING WITH FOAM
INSULATION AIR TIGHT AFTER THREADED RODS 4/21/13
VOLUME DAMPER WITH
LINES ARE INSTALLED. LOCKING QUADRANT
SUPPLY AIR DUCT BDD
INSULATED ROOF CURB HANGER IONIZATION TYPE SMOKE DETECTOR TO
WITH ACOUSTICAL FILTER ACCESS SHUT DOWN UNIT UPON ACTIVATION.
LINING
FURNISHED BY M.C., INSTALLED BY M.C.,
S
WIRED TO FIRE ALARM SYSTEM BY E.C.
PROTECT INSULATION FAN LOCATE UPSTREAM OF OUTSIDE AIR
FROM SCREENING WITH FLASHING & COUNTERFLASHING INTAKE. FOR ADDITIONAL INFO, SEE
A.D.
ELECTRICAL PLANS.
12" MIN.
ROOF PENETRATION DETAIL EXHAUST FAN (CEILING) DETAIL AIR HANDLING UNIT DETAIL MECHANICAL
3 NO SCALE 2 NO SCALE 1 NO SCALE DETAILS
M-03
GENERAL ELECTRICAL NOTES LIGHTING FIXTURE SCHEDULE ELECTRICAL SYMBOL LEGEND
CATALOG LAMP DATA BALLAST DATA INPUT
MARK MANUF. VOLTS MOUNTING DESCRIPTION
I. GENERAL REQUIREMENTS: 8. FUSES 0 - 600 AMPS SHALL BE UL CLASS "RK-1" LOW PEAK DUAL NUMBER NO. TYPE NO. TYPE WATTS CIRCUIT CONDUCTORS CONCEALED IN FLOOR, WALL OR CEILING.
ELEMENT TIME DELAY WITH 200,000 AMPERE INTERRUPTING
1. ELECTRICAL CONTRACTOR IS TO FURNISH AND PAY FOR ALL RATING AS MANUFACTURED BY BUSSMANN, UNLESS NOTED A PHILLIPS SM120V 2 31W LED 120V 1 DRIVER 62W SURFACE 2X4 LED SURFACE MOUNTED ARROWHEAD INDICATES HOMERUN TO PANEL NOTED.
LABOR, MATERIAL, EQUIPMENT, PERMITS & FEES REQUIRED FOR THE OTHERWISE. MAX GREEN | URBAN | SMART ARCHITECTURE
COMPLETE INSTALLATION OF ALL SYSTEMS IN THIS SECTION OF INDICATES HOT LEG OF CIRCUIT TO BE CARRIED OVER TO NEXT DEVICE. SEE PLANS FOR 19 WEST HARGETT STREET #700
WORK. 9. 60W CONTROL SCHEME. RALEIGH, NORTH CAROLINA 27601
B BY OWNER - - - 120V - - PENDANT STAR PENDANT, SELECTION BY OTHERS. www.aoarchitect.com
SPLICING CONNECTORS, LUGS, ETC SHALL BE IDENTIFIED FOR USE MAX
2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH NEC AND WITH THE MATERIAL (CU/AL) OF THE CONDUCTOR AND SHALL BE JUNCTION BOX CEILING MOUNTED.
ALL OTHER APPLICABLE CODES. EC IS TO COORDINATE W/ G.C. IN PROPERLY INSTALLED.
C GOTHAM 8" EVO CYL 1 25W LED 120V 1 DRIVER 25W SURFACE CEILING MOUNTED CAN LIGHT J JUNCTION BOX FLOOR MOUNTED.
REGARDS TO PROJECT TIMELINE, WORK HOURS, AS WELL AS ANY
BONDING OR INSURANCE REQUIREMENTS. 10. RECEPTACLES IN COMMERCIAL AREAS SHALL BE 20 AMP
COMMERCIAL SPECIFICATION GRADE EQUAL TO HUBBELL JUNCTION BOX WALL MOUNTED AT HEIGHT INDICATED ON DRAWINGS.
SERIES. GROUND FAULT RECEPTACLES SHALL BE EQUAL TO C1 LITHONIA DOM6 LED 1 16W LED 120V 1 DRIVER 16W RECESSED RECESSED 6" LED DOWNLIGHT
3. ALL ELECTRICAL & LIGHTING EQUIPMENT SHALL BE PROVIDED
COOPER VGF SERIES. SINGLE POLE SWITCH, 20A, 120/277 VOLT, 48" A.F.F. TO CENTER.
COMPLETE WITH ALL ACCESSORIES, HANGERS, SUPPORTS,
"3" INDICATES 3-WAY SWITCH.
CONTROLS, ETC FOR A FULLY FUNCTIONING SYSTEM REGARDLESS
OF PRESENCE ON PLANS. 11. LIGHTING SWITCHES SHALL BE 20 AMP COMMERCIAL
SPECIFICATION GRADE EQUAL TO HUBBELL SERIES.
G BY OWNER - - - 120V - - 60W
MAX
WALL TIN WALL SCONCE, SELECTION BY OTHERS. "4" INDICATES 4-WAY SWITCH.
"D" INDICATES DIMMER SWITCH OF TYPE TO SUIT LOAD.
maple
ENGINEERING, pllc
"K" INDICATES KEY OPERATED SWITCH. 1405 HILLSBOROUGH ST
4. ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE RALEIGH, NC 27605 LIC.#: P-0990
12. ALL EXTERIOR FIXTURES AND DEVICES SHALL BE RATED FOR H JUNO G5.7.0 1 4.8 W LED 120V 1 DRIVER 4.8W RECESSED 4" LED SPOT, CEILING MOUNTED "M" INDICATES 120V, 20A MOTOR RATED TOGGLE SWITCH. P:919-341-4247 F:919-890-3797
GUARANTEED TO BE FREE OF DEFECTS FOR A PERIOD OF ONE (1) plumbing mechanical electrical
YEAR AFTER FINAL ACCEPTANCE OF WORK OR IN ACCORDANCE
REQUIRED. INDICATES FLUORESCENT FIXTURES DUAL SWITCHED, INBOARD/OUTBOARD SWITCHED
WITH THE MANUFACTURER'S STANDARD GUARANTEE, IF LONGER. ROPE LIGHT MOUNTED IN CURIO BOX. SELECTION PROJECT No.:
SEPARATELY.
EXISTING EQUIPMENT IS EXCLUDED FROM WARRANTY
REQUIREMENT. IV. COORDINATION:
J BY OWNER - - - 120V - - 10W
MAX
SURFACE BY OTHERS. COORDINATE INSTALL W/ ARCH. 1301
SINGLE RECEPTACLE, 20 AMP, 120 VOLT, 18" A.F.F. TO CENTER.
5. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL 30W LENSED DECORATIVE PENDANT, SELECTION BY
1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE CLOSELY K BY OWNER - - - 120V - - PENDANT DUPLEX RECEPTACLE, 20 AMP (15 AMP RESIDENTIAL, UON), 120 VOLT, 18" A.F.F. TO CENTER.
LOCATION AND ARRANGEMENT OF ALL MATERIALS AND MAX OTHERS.
WITH ALL OTHER TRADES TO AVOID CONFLICT AND ENSURE "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE.
EQUIPMENT. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS OTHER TRADES PROVIDE MEASURES TO ACCOMMODATE "WP" INDICATES WEATHERPROOF.
BUILDING CONSTRUCTION AND ALL OTHER WORK WILL PERMIT. SINGLE CIRCUIT LOW VOLTAGE TRACK W/ LED
ELECTRICAL WORK (I.E. ACCESS DOORS, SLAB/WALL/ROOF L JUNO TF25TL 1 13 W LED 120V 1 DRIVER 13W TRACK "ASW" ABOVE SHOW WINDOW.
LENSED HEADS. EXACT HEAD TYPE BY OTHERS.
OPENINGS, ETC). POSITION RECEPTACLE IN ACCORANCE W/ NEC REQ'S.
6. DO NO SCALE DRAWINGS FOR MEASUREMENT.
2. LOCATE LIGHTS IN ACCORDANCE WITH ARCHITECTURAL M BY OWNER - - - 120V - - 30W PENDANT DECORATIVE PENDANT, SELECTION BY OTHERS. QUADRUPLEX RECEPTACLE, AS ABOVE, 18" A.F.F.
7. INFORMATION GIVEN IN SCHEDULES INCLUDES BOTH DESCRIPTION REFLECTED CEILING PLANS (IF PROVIDED). MAX
OF PRODUCT AND MANUFACTURER'S MODEL #. IF CONFLICT IS DUPLEX RECEPTACLE, AS ABOVE, SPLIT WIRED, TOP HALF SWITCHED, 18" A.F.F.
PRESENT BETWEEN DESCRIPTION AND MODEL #, EQUIPMENT EXIT-EMERGENCY LIGHT COMBO. (2) ADJ. HEADS.
3. E.C. TO COORDINATE ELEVATION OF WALL MOUNTED LIGHTS 120,
DESCRIPTION SHALL TAKE PRECEDENT. IN CASE OF CONFLICT LITHONIA LHQM 2 5.4 W T-5 - - 3.3 WALL BATTERY BACK-UP. RED ILLUMINATED EXIT SIGN.
(INTERIOR & EXTERIOR) W/ ARCHITECT/ARCH PLANS. 277 DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE
BETWEEN THE PLANS AND NOTES/SPECIFICATIONS OR CONFLICT HOUSING COLOR BY ARCH.
BACKSPLASH, AS APPROPRIATE, OR AT HEIGHT INDICATED.
BETWEEN INFORMATION PRESENTED ON THE PLANS OR IN THE 4. E.C. TO COORDINATE W/ P.C. & M.C. REGARDING POWER AND 120, GEN. PURPOSE EMERGENCY LIGHT. (2) ADJ. HEADS.
NOTES/SPECIFICATIONS, THEN THE MOST RESTRICTIVE SHALL TAKE LITHONIA ELM2 2 5.4 W - - 1.2 SEE PLAN
FIRE ALARM CONNECTIONS TO MECHANICAL AND PLUMBING 277 BATTERY BACK-UP. DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE
PRECEDENT. EQUIPMENT. BACKSPLASH, AS APPROPRIATE, OR AT HEIGHT INDICATED, WITH GFI PROTECTION.
REMOTE EXTERIOR EMERGENCY LIGHT. TWIN HEAD.
120, -
8. BEFORE BID EC IS RESPONSIBLE FOR CLARIFYING W/ G.C. ANY 5. E.C. TO VERIFY ALL REQUIREMENTS AND COORDINATE EXACT E LITHONIA ELAT QWP 2 1.5W LED - - SEE PLAN BATTERY BACK-UP (CAN BE WIRED TO EXIT UNIT). RECESSED FLUSH FLOOR DUPLEX RECEPTACLE WITH BRASS COVERPLATE. COORDINATE
277
CONFUSION IN REGARDS TO RESPONSIBILITY OF WORK TO BE LOCATION OF INCOMING ELECTRICAL SERVICE WITH LOCAL WET LOCATION LISTED. EXACT FINISH WITH ARCHITECT AND OWNER.
PERFORMED OR MATERIALS TO BE PROVIDED. THE SUBMITTAL OF POWER COMPANY PRIOR TO PROJECT START-UP. NOTIFY NOTES:
THE BID BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE ENGINEER OF ANY CHANGES AS MAY BE REQUIRED. 1. UNLESS OTHERWISE NOTED COLOR & FINISH OF FIXTURE HOUSING, BAFFLE, OR SIMILAR EXPOSED ELEMENTS TO BE BY ARCHITECT. 208V RECEPTACLE, SEE PLANS FOR NEMA CONFIGURATION.
CONTRACTOR UNDERSTANDS THOROUGHLY AND COMPLETELY THE 2. WHERE MASTER SLAVE WIRING CONFIGURATIONS IS INDICATED THE CONTRACTOR SHALL VERIFY THE QUANTITY AND TYPE OF BALLASTS REQUIRED TO PERMIT BI-LEVEL SWITCHING. WHERE
SCOPE OF THE WORK INVOLVED, AND HAS INCLUDED ON THE BID 6. E.C. TO VERIFY DEVICE PLATE COLOR AND MATERIAL WITH BI-LEVEL LIGHTING IS INDICATED INBOARD AND OUTBOARD LAMPS SHALL BE SWITCHED SEPARATELY. TELEPHONE OUTLET, 18" A.F.F. TO CENTER OR ALIGN MOUNTING HEIGHT WITH ADJACENT
ALL THE NECESSARY ITEMS TO CARRY OUT THIS SECTION OF WORK. ARCHITECT PRIOR TO PURCHASE. 3. EXIT AND EMERGENCY LIGHTING FIXTURES SHALL BE CIRCUITED TO AN UNSWITCHED LEG OF A NORMALLY ON LOCAL LIGHTING CIRCUIT (UNLESS NOTED OTHERWISE),INCLUDE 90 MINUTE BATTERY DEVICE, UNLESS OTHERWISE NOTED. PROVIDE 3 4" CONDUIT TO ACCESSIBLE CEILING. ALIGN
BACKUP & TESTING MEANS. MOUNTING HEIGHT WITH ADJACENT DEVICE.
9. AS SOON AS POSSIBLE (AND NOT MORE THAN 30 DAYS) AFTER 4. PROVIDE DISCONNECT FOR LUMINAIRES WITH LINEAR FLUORESCENT LAMPS AND/OR SERVICEABLE BALLASTS PER NEC 410.130(G).
V. EXECUTION:
CONTRACT IS SIGNED, THE EC SHALL PROVIDE SUBMITTALS OF 5. FIXTURES WITH A STANDARD FACTORY INSTALLED EMERGENCY OPTION SHOULD USE THAT WHERE "EMC" IS SHOWN. DATA OUTLET, 18" A.F.F. TO CENTER OR ALIGN MOUNTING HEIGHT WITH ADJACENT DEVICE,
EQUIPMENT HE/SHE INTENDS TO PURCHASE FOR REVIEW AND 6. ALL LAMPS OF A SINGLE FIXTURE TYPE INSTALLED IN EACH AREA/ROOM/SPACE ARE TO BE OF SAME TEMPERATURE/COLOR. UNLESS OTHERWISE NOTED. PROVIDE 1" CONDUIT TO ACCESSIBLE CEILING.
1. E.C. TO FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN
COMMENT BY THE ENGINEER. ENGINEER IS TO APPROVE
INSTALLING ELECTRICAL EQUIPMENT. ENSURE REQUIRED
SUBMITTALS BEFORE EQUIPMENT IS ORDERED. TELEPHONE/DATA OUTLET, 18" A.F.F. TO CENTER OR ALIGN MOUNTING HEIGHT WITH
MAINTENANCE ACCESS AND CLEARANCES ARE MAINTAINED. IF
CONFLICT EXISTS BETWEEN THESE PLANS AND MFG INSTRUCTIONS
LIGHTING SYSTEMS ADJACENT DEVICE, UNLESS OTHERWISE NOTED. PROVIDE 1" CONDUIT TO ACCESSIBLE
10. ALL EXISTING EQUIPMENT AND SYSTEMS ARE ASSUMED BY ENGINEER CEILING.
CONTACT ENGINEER. NCECC SECTION 505 & 506
TO BE IN GOOD WORKING ORDER. BEFORE BEGINNING WORK E.C.
IS TO ENSURE ANY EQUIPMENT & SYSTEMS TO REMAIN ARE HEAVY DUTY FUSIBLE/NON-FUSIBLE DISCONNECT SWITCH, NUMBERS INDICATE FRAME SIZE,
2. A COMPLETE GROUNDING SYSTEM SHALL BE PROVIDED AND
PROPERLY FUNCTIONING. NOTIFY G.C. IMMEDIATELY IF PROBLEMS
INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NEC,
LIGHTING POWER DENSITY CALCULATION COMPLIANCE DESIGNER STATEMENT: NUMBER OF POLES AND FUSING. PROVIDE NEMA 1 ENCLOSURE INSIDE. PROVIDE NEMA 3
ARE DISCOVERED. TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES ENCLOSURE FOR ALL SWITCHES LOCATED OUTSIDE.
AND AS SHOWN ON THE DRAWINGS. INTERIOR LIGHTING POWER DENSITY CALCULATION PER TABLE 505.5.2. SEE LIGHTING WITH THE LIGHTING SYSTEMS REQUIREMENTS OF THE NORTH CAROLINA ENERGY 30/3/FPN "FPN" INDICATES FUSE PER EQUIPMENT NAMEPLATE
11. ALL QUESTIONS MUST BE SUBMITTED IN RFI FORMAT TO THE FIXTURE SCHEDULE FOR FIXTURE INFORMATION. CONSERVATION CODE, SECTION 505 & 506 AND ANY LOCAL AMENDMENTS THEREOF. "NF" INDICATES NON-FUSED.
3. PROVIDE A PULLWIRE IN ALL EMPTY CONDUITS.
ARCHITECT AND MUST BE ADDRESSED BY THE APPROPRIATE "MS" INDICATES MOTOR STARTER OF TYPE TO SUIT LOAD.
INTERIOR WATTAGE SPECIFIED VS. ALLOWED 2,050 VS. 2,512
DESIGNER OF RECORD PROIR TO BECOMING A PROPOSED SIGNED:
4. PROVIDE A TYPED DIRECTORY IN ALL PANELBOARDS CLEARLY
CHANGE ORDER. EXTERIOR LIGHTING POWER DENSITY CALCULATION PER TABLE 505.6.2. SEE LIGHTING
DESCRIBING THE LOCATION OF AND TYPE OF LOAD BEING NAME: ZACK L. TOMLIN, PE 208Y/120V PANEL, SURFACE OR RECESS MOUNTED, SEE SCHEDULE FOR DETAILS.
FIXTURE SCHEDULE FOR FIXTURE INFORMATION.
SERVED FOR ALL CIRCUITS. PROVIDE ENGRAVED PHENOLIC
II. DIVISION OF WORK: TITLE: ELECTRICAL ENGINEER
NAMEPLATES FOR ALL PANELBOARDS AND DISCONNECT TRADABLE EXTERIOR WATTAGE SPECIFIED VS. ALLOWED EXIST VS. EXIST 480Y/277V PANEL, SURFACE OR RECESS MOUNTED, SEE SCHEDULE FOR DETAILS.
SWITCHES, WHITE LETTERS ON BLACK BACKGROUND. NONTRADABLE EXTERIOR WATTAGE SPECIFIED VS. ALLOWED N/A VS. N/A
1. ALL LOW VOLTAGE WIRING RELATED TO MECHANICAL EQUIPMENT
EF FAN, PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL
AND SYSTEMS IS THE RESPONSIBILITY OF THE MECHANICAL 5. PROVIDE LABELING ON SERVICE EQUIPMENT INDICATING
ADDITIONAL PRESCRIPTIVE COMPLIANCE CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED.
CONTRACTOR (ANY LOW VOLTAGE FIRE ALARM WIRING TO BE BY AVAILABLE FAULT CURRENT IN ACCORDANCE W/ NEC 110.24.
E.C.). ALL HIGH VOLTAGE CONNECTIONS TO MECHANICAL NOT APPLICABLE (RENOVATION PROJECT) 506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING WH WATER HEATER, PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR, WIRED BY
EQUIPMENT, TO BE PROVIDED AND INSTALLED BY E.C. (SEE 6. ALL PENETRATIONS THROUGH EXTERIOR WALLS & ROOF SHALL BE 506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT 506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY ELECTRICAL CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED.
EQUIPMENT SCHEDULE FOR DISCONNECT RESPONSIBILITY). FLASHED & COUNTER-FLASHED IN A WATERPROOF MANNER.
506.2.2 REDUCED LIGHTING POWER DENSITY X 506.2.6 AUTOMATIC DAYLIGHTING CONTROL SYSTEMS
506.2.3 ENERGY RECOVERY VENTILATION SYSTEM RECESSED MOUNTED 2x4 FLUORESCENT TROFFER, SEE FIXTURE SCHEDULE FOR DETAILS.
2. G.C. TO BE RESPONSIBLE FOR PROVIDING AND INSTALLING ANY 7. SEAL ALL PENETRATIONS OF SMOKE PARTITIONS OR FIRE RATED
ACCESS DOORS (WALL, FLOOR, CEILING) RELATED TO ELECTRICAL WALLS, CEILING, FLOORS IN ACCORDANCE W/ APPROPRIATE
SYSTEM. E.C. RESPONSIBLE FOR COMMUNICATING TO G.C. SIZE U.L. PENETRATION DETAIL AND NC BUILDING CODE. TRACK LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS.
AND LOCATION OF REQ'D ACCESS DOOR(S).
8. PENETRATIONS OF NON-RATED WALLS, PARTITIONS AND FLOOR SURFACE MOUNTED FLUORESCENT STRIP, SEE FIXTURE SCHEDULE FOR DETAILS.
3. ELECTRICAL CONTRACTOR IS TO EMPLOY THE SERVICES OF THE OF COMBUSTIBLE CONSTRUCTION SHALL BE FIRESTOPPED WITH
G.C. FOR CUTTING AND PATCHING OF WALLS, FLOORS & CEILINGS MATERIALS EQUIVALENT TO TWO INCHES OF WOOD. WALL MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS.
RELATED TO THE INSTALLATION OF ELECTRICAL EQUIPMENT & FIRESTOPPING SHALL COMPLY WITH ASTM E-814.
SYSTEMS. SURFACE, RECESSED OR GROUND MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR
9. ANY NOTCHING, DRILLING, BORING OR OTHER ALTERATION TO DETAILS.
4. G.C. RESPONSIBLE FOR PAINTING OF ANY EXPOSED CONDUIT, BUILDING STRUCTURE SHALL BE PERFORMED IN A CODE NOTE:
WIRE, BOXES ETC. E.C. RESPONSIBLE FOR CLEANING AND APPROVED METHOD AND NOT THREATEN THE INTEGRITY OF THE CONFIRM ALL LIGHT M ELECTRIC UTILITY METER LOCATION.
PREPARING ITEMS FOR PAINT, COORDINATE W/ G.C. BUILDING STRUCTURE. SELECTIONS W/ OWNER &
ARCHITECT BEFORE BID & ### KITCHEN EQUIPMENT TAG.
5. E.C. TO COORDINATE W/ G.C. PRIOR TO BID REGARDING HIRING 10. SUPPORT ALL CONDUIT AND EQUIPMENT IN ACCORDANCE W/ PURCHASE.
OF FIRE ALARM, DATA/TELE & SECURITY SUB-CONTRACTORS (IF NEC. ANY SUSPENDED MATERIALS SHALL BE DIRECTLY DEMO'D LIGHT FIXTURE OR SIMILAR.
APPLICABLE). SUPPORTED BY THE BUILDING STRUCTURE. SEALS:
DEMO'D RECEPTACLE OR SIMILAR.
III. MATERIALS: 11. PENETRATIONS OF ALL EXTERIOR WALLS, FLOORS AND CEILINGS
SHALL BE SEALED IN AN AIR TIGHT MANNER AND IN
1. ALL MATERIAL, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE
NEW UNLESS OTHERWISE NOTED AND SHALL CONFORM TO THE
ACCORDANCE W/ 2012 NCECC APPENDIX 2 DETAILS. ELECTRICAL ABBREVIATIONS
STANDARDS OF THE UNDERWRITER'S LABORATORIES, INC., AND THE 12. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR
CEILING
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. PROTECTING ALL ELECTRICAL EQUIPMENT FROM FOREIGN 1-1/2" CONDUIT SLEEVE 18" DIMENSION INDICATES HEIGHT ABOVE FINISHED FLOOR AT WHICH CENTER OF
MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). PULLSTRING DEVICE IS TO BE MOUNTED.
2. ALL MATERIALS INSTALLED IN RETURN PLENUM ARE TO BE PLENUM UPON COMPLETION OF WORK THE ELECTRICAL CONTRACTOR NOTE:
FIRE ALARM HORN,
RATED. SHALL CLEAN, WASH, ETC ALL ITEMS AND EQUIPMENT WITHIN HIS DEVICE HEIGHTS ARE TO 1" CONDUIT
HORN/STROBE OR AFF ABOVE FINISHED FLOOR.
SCOPE OF WORK AND LEAVE ALL ITEMS BRIGHT AND CLEAN. BE AS INDICATED UNLESS 4/21/13
STROBE.
3. PROVIDE HANGERS & SUPPORTS APPROVED FOR USE BY NEC. FIRE OTHERWISE NOTED.
AFG ABOVE FINISHED GRADE.
13. IN REQUIRED FIRE RATED WALLS AND PARTITIONS, OPENINGS FOR
CEILING
4. ALL FIRE SEALANTS TO BE U.L. LISTED AND APPROVED FOR USE W/ INSTALLATION OF BOXES THAT ARE GREATER THAN 16 SQUARE E.C. ELECTRICAL CONTRACTOR.
ALIGN DEVICES WHEN WALL
APPROPRIATE U.L. PENETRATION DETAIL. INCHES SHALL BE PROTECTED AS REQUIRED BY U.L.
MOUNTED CLOSE ON MOUNTED
SAME WALL FPN FUSE PER EQUIPMENT NAMEPLATE REQUIREMENTS.
5. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 14. UNLESS OTHERWISE INDICATED THE ELECTRICAL CONTRACTOR TELEPHONE RECEPTACLE
FLOOR TO
VOLTS.MINIMUM SIZE SHALL BE #12 AWG UNLESS OTHERWISE AT HIS/HER DISCRETION MAY COMBINE MULTIPLE CIRCUITS INTO LIGHT SWITCH G.C. GENERAL CONTRACTOR.
TELE/DATA DECK WALL
NOTED ON THE DRAWINGS. ALL WIRE #8 AWG AND LARGER SHALL A SINGLE CONDUIT AND DE-RATE WIRE. COMBINING AND OR DIMMER
BE STRANDED. ALL CONDUCTORS #10 AND SMALLER MAY BE DE-RATING IS TO BE DONE IN STRICT ACCORDANCE W/ NEC. SWITCH M.C. MECHANICAL CONTRACTOR.
SOLID OR STRANDED, UNLESS OTHERWISE NOTED. CONDUCTOR FIRE ALARM
INSULATION SHALL BE TYPE THHN UNLESS OTHERWISE NOTED. ALL 15. DEVICES INCLUDING GFCI PROTECTION MUST HAVE THEIR PULL STATION
80"
46"
36" MAX
BELOW. EMT SHALL NOT BE USED IN OR UNDER CONCRETE SLABS, 16. COORDINATE WITH THE CABLE TV AND TELEPHONE UTILITIES FOR MAX COUNTER FACP FIRE ALARM CONTROL PANEL.
OR IN MASONRY WALLS. USE SCHEDULE 40 PVC OUTDOORS SERVICE ENTRANCE AND CABLING REQUIREMENTS PRIOR TO DEPTH = 24"
WHERE NOT SUBJECT TO PHYSICAL DAMAGE OR BELOW FLOOR ANY PURCHASING. INSTALLATION MUST COMPLY WITH THEIR SMP SPRINKLER MONITORING PANEL.
18"
SLAB. MINIMUM CONDUIT SIZE TO BE 1/2". TYPE MC AND AC RESPECTIVE REGULATIONS AND REQUIREMENTS. FLOOR
CABLE MAY BE USED WHERE PERMISSIBLE BY NEC. FLEXIBLE FLOOR NL NIGHT LIGHT, LIGHT NOT SWITCHED.
CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING 17. ALL EXIT & EMERGENCY LIGHTS ARE TO BE CIRCUITED TO NOTE:
EQUIPMENT AND LUMINAIRES, BUT SHALL NOT EXCEED 6' IN LENGTH. UN-SWITCHED LEG OF LOCAL NORMALLY ON LIGHTING CIRCUIT. NOTE: FOR INTERIOR WALLS WITHOUT
7. METAL CONDUIT COUPLINGS TO BE COMPRESSION TYPE OR 18. RECEPTACLE, LIGHT SWITCHES AND OTHER CONTROL DEVICES
MOUNTING LOCATIONS OF RECEPTACLES, SWITCHES AND ALL
OTHER CONTROL DEVICES SHALL BE IN ACCORDANCE WITH
INSULATION. E.C. MAY OMIT CONDUIT & MOTION SENSOR LEGEND
OUTLET BOX. PROVIDE PULL STRING &
THREADED WHEN ACCESSIBLE TO BUILDING OCCUPANTS. METAL ARE TO BE INSTALLED IN ACCORDANCE W/ ANSI A117.1 AND ANSI A117.1 AND ADA REQUIREMENTS (FHA REQ'S FOR PLASTER RING.
COUNDUIT COUPLINGS MAY BE SET-SCREW TYPE WHEN ADA REQ'S CONCERNING HEIGHT AND ACCESSIBILITY. FHA MULTI-FAMILY AND RESIDENTIAL PROJECTS) M0 WALL SWITCH MICROPHONIC OCCUPANCY SENSOR EQUAL TO SENSOR SWITCH MODEL WS
CONCEALED IN BUILDING STRUCTURE OR LOCATED MORE THAN 10' REQ'S TO BE FOLLOWED FOR MULTI-FAMILY AND RESIDENTIAL PDT. TIME DELAYS 10 MINUTES FOR ON/OFF. ELECTRICAL SCHED,
AFF. PLASTIC CONDUIT COUPLINGS TO BE SOCKET GLUED TYPE. PROJECTS.
TYPICAL DEVICE MOUNTING HEIGHTS DATA/TELE/CATV OUTLET NOTES & DETAILS
2 NO SCALE
1 NO SCALE
NOTE:
THE CONTRACTOR IS TO PROVIDE AND INSTALL ALL RELAYS, CONTROLS, SWITCHES, ETC FOR
A FULLY FUNCTIONING SYSTEM REGARDLESS OF PRESENCE OR ABSENCE ON PLANS.
E-01
ON ROOF (FIELD LOCATE) FIRE RATING LEGEND
A-22,24 A-26,28 2-HR WALL
60/2/FPN,WP 60/2/FPN,WP *2ND FLR CEIL. IS 2-HR RATED
HP-1 HP-2
L K
EQUIPMENT SCHEDULE A-16,18,20 B-39 B-39
L WH-1 B-41
N H
OFFICE 3
DIR. CONN.
OFFICE K R
M 203
C
PLUG
203 M
VOLT PHASE AMPS
M0 B
ITEM
# QTY. DESCRIPTION
B-14 B-14
B-41
maple
ENGINEERING, pllc
1405 HILLSBOROUGH ST
K RALEIGH, NC 27605 LIC.#: P-0990
H
E1 1 COFFEE ROASTER 120 1 5.0 - X P:919-341-4247 F:919-890-3797
K
B-10
K
K
H
K
A B-10 B
H
L L
B
104
B-6 B-35
A
C1 C1 C WOMENS
NL 104
A
J E10 SEALS:
EF EF
B-21 B-37
B-27
G G
1
B-8
J
E
B-19 A-5,7 B-25 B-25 B-29 B-15 A-1,3
DINING
B-35
106 E20
L
E9 E13 E7 E3
DINING
C B-20 106
2
BAR L
4/21/13
J BAR
102
102
B-20
B-2 E4 E8 E11
E1 E6 E2
2 B E5 B-23
B-1 A-9,11 B-17 B-3
L
K B-13
K B-9
K J B-3
K
K B-11 B-35
E-02
HALLWAY 3 PHASE, 4 WIRE
PANEL "A" LOAD SUMMARY HALLWAY 3 PHASE, 4 WIRE
PANEL "B" LOAD SUMMARY
VOLTAGE: 208Y/120V PANEL: A FLUSH MOUNTED
LOAD TYPE kVA DEM. kVA
VOLTAGE: 208Y/120V PANEL: B FLUSH MOUNTED
LOAD TYPE kVA DEM. kVA
AMPS: 400-MLO LOAD PER PHASE NEMA 1 CONN. FACT. DEM. AMPS: 200-MLO LOAD PER PHASE NEMA 1 CONN. FACT. DEM. GREEN | URBAN | SMART ARCHITECTURE
LOADS ON 350 AMP DISC @ METER LOADS ON 200 AMP BREAKER IN PANEL "A"
NOTES -DESCRIPTION- POLE
WIRE BRK CKT
A B C
CKT BRK WIRE
POLE -DESCRIPTION- NOTES NOTES -DESCRIPTION- POLE
WIRE BRK CKT
A B C
CKT BRK WIRE
POLE -DESCRIPTION- NOTES 19 WEST HARGETT STREET #700
SIZE SIZE # # SIZE SIZE SIZE SIZE # # SIZE SIZE RALEIGH, NORTH CAROLINA 27601
LIGHTS (2000 SQFT. @ 3 W/SQFT > CONN. LOAD) 6.0 1.25 7.5 LIGHTS (2000 SQFT. @ 3 W/SQFT > CONN. LOAD) 6.0 1.25 7.5
1 2.5 4.4 2 GFI COFFEE ROASTER 1 12 20 1 0.6 0.3 2 20 12 1 LTS: DINING/ ENTRY/ BAR C www.aoarchitect.com
COFFEE MACHINE 2 10 30 3
3 2.6 6.8 4 200 0 3 PANEL B TRACK LIGHTS 2.3 1.25 2.9 GFI REC: BAR COUNTER 1 12 20 3 1.0 0.3 4 20 12 1 LTS: RESTROOMS C TRACK LIGHTS 2.3 1.25 2.9
5 3.1 9.3 6 SPARE 1 - 20 5 0 0.1 6 20 12 1 LTS: NIGHT LIGHTS
CONVECTION OVEN 2 8 40
7 3.1 0 8 - - 1 SPACE 1st 10 kVA 7.0 1.0 7.0 SPARE 1 - 20 7 0 0.3 8 20 12 1 LTS: BAR TRACK C 1st 10 kVA 6.8 1.0 6.8
9 4.7 0 10 - - 1 SPACE GFI GRINDER: ESPRESSO 1 12 20 9 0.5 0.3 10 20 12 1 LTS: OVERHEAD DINING C
ESPRESSO MACHINE 2 8 40 RECEPTACLES REMAINDER 0.0 0.5 0.0 RECEPTACLES REMAINDER 0.0 0.5 0.0
11 4.7 0 12 - - 1 SPACE GFI GRINDER: ESPRESSO 1 12 20 11 0.4 0.8 12 20 12 1 LTS: LOUNGE C
SPACE 1 - - 13 0 0 14 - - 1 SPACE SHOW-WINDOW (26 FEET @ 125%) 0.6 10.8 6.5 GFI GRINDER: ESPRESSO 1 12 20 13 0.3 1.0 14 20 12 1 REC: OFFICE/CONFERENCE SHOW-WINDOW (26 FEET @ 125%) 0.6 10.8 6.5
SPACE 1 - - 15 0 8.0 16
SPACE 1 - - 33 0 3.8 34
COND. PUMP 0.4 1.0 0.4 REC: SHOW WINDOW 1 12 20 33 0.6 0 34 - - 1 SPACE COND. PUMP 0.4 1.0 0.4
SPACE 1 - - 35 0 3.8 36 REC: DINING 1 12 20 35 1.4 0 36 - - 1 SPACE
SPACE 1 - - 37 0 3.8 38 50 6 3 AH-2 SIGN CIRCUIT 1.2 1.25 1.5 REC: RESTROOM 1 12 20 37 0.6 0 38 - - 1 SPACE SIGN CIRCUIT 1.2 1.25 1.5
SPACE 1 - - 39 0 3.8 40 REC: LOUNGE 1 12 20 39 0.8 0 40 - - 1 SPACE
MISCELLANEOUS 0.0 1.0 0.0 MISCELLANEOUS 0.0 1.0 0.0
SPACE 1 - - 41 0 0 42 - - 1 SPACE REC: LOUNGE PLUG MOLD 1 12 20 41 1.2 1.2 42 20 12 1 SIGN CIRCUIT TC
29.1 36.7 36.2 TOTALS 108.1 113.9 4.4 6.8 9.3 TOTALS 25.8 31.1
TOTAL CONNECTED kVA: 102.0 DEMAND kVA: 113.9 TOTAL CONNECTED kVA: 20.5 DEMAND kVA: 31.1
TOTAL AMPS @ 208 V 3 PHASE 316.1 TOTAL AMPS @ 208 V 3 PHASE 86.3
PANEL RMS SYM. AMPS: SEE RISER DEMAND AMPS: 316.1 PANEL RMS SYM. AMPS: SEE RISER DEMAND AMPS: 86.3
NOTE:
LOAD SUMMARY FOR PANEL "A" INCLUDES LOADS FROM PANEL "B".
1. PANEL SHALL BE EQUAL TO SQUARE D NQ. 1. PANEL SHALL BE EQUAL TO SQUARE D NQ. LIGHTING CONTACTOR
2. PROVIDE HACR BREAKERS FOR HVAC EQUIPMENT. 2. PROVIDE SWD/HID RATED BREAKERS FOR LIGHTING CIRCUITS.
3. PROVIDE HACR BREAKERS FOR HVAC EQUIPMENT.
4. GFI - PROVIDE GFCI BREAKER FOR CIRCUIT. GFCI RECEPTACLES MAY BE USED IN LIEU OF GFCI
BREAKERS SO LONG AS THE DEVICE(S) CONFORM TO NEC CODE REQUIREMENTS FOR GFCI LIGHTING CIRCUITS CIRCUITS
PROTECTION. FR PANEL TO
5. C - CIRCUIT THROUGH LIGHTING CONTACTOR. SEE DETAIL. FIXTURES
6. TC - CIRCUIT THROUGH 7-DAY PROGRAMMABLE ASTRONOMICAL TIME CLOCK. COORDINATE EXACT LINE
SIGN REQUIREMENTS AND LOCATION W/ OWNER. c
PROG. LOAD
SWITCH
(SEE SWITCH BANK DETAIL)
NOTE:
E.C. TO COORDINATE # OF CIRCUITS
CONTROLLED AND NATURE OF LOADS W/
CONTACTOR MFG.
42,000AIC 208Y/120V
NOTE 3
PANEL PANEL 1200A
B A PROG. SWITCH
MCB FUTURE EQUIP.
NOTE 5
200 A MLO 400 A MLO
208Y/120V 208Y/120V
MAIN SERVICE #:##
NOTE 8 NOTE 8 M M M
M NOTE 2
DISCONNECT OFF OFF OFF
NOTE 5
LIGHT CONTACTOR
IS POSSIBLE (HIGHER KVA, LOWER IMPEDANCE, LARGER SECONDARY WIRE, SHORTER 2. 320A METER BASE PER UTILITY REQUIREMENTS. METER BY UTILITY.
SECONDARY LENGTH, ETC).
3. SERVICE ENTRANCE RATED WEATHERPROOF DISCONNECT SIZED AND FUSED
# COND. WIRE L.
TX KVA TX %Z VOLTAGE PHASE WIRE SIZE
(FEET)
WIRE "C" AS INDICATED.
4. (4)#400kcmil CU, #3 CU GND, 3" CONDUIT.
750 3.5 208 3 4 500kcmil 150 22185 SUITE 24
S. DAWSON ST
5. (4)#400kcmil CU, 3" CONDUIT.
CURRENT MULT.
TX ISC f M ISC (AMPS)
(L TO L) (ISC) 6. E.C. TO CONFIRM PRESENCE OF GROUNDING/BONDING SYSTEM (NEC 250).
2082 28.57 59480 0.8372 0.5443 32375 7. PROVIDE PLACARD AT SERVICE ENTRANCE PANELS, DISCONNECTED, AND
EXISTING ELECTRICAL SERVICE
AT METER BASES. SEE PLACARDS DETAIL. M
M
8. PANEL & BREAKERS ARE TO BE SERIES RATED WITH SERVICE DISCONNECT TO DATE: 4/21/13
DRAWN BY:CLR/JMS/RSA
PROVIDE 42,000 AIC RATING.
M
W. HARGETT ST.
E-03
FIRE RATING LEGEND
2-HR WALL
*2ND FLR CEIL. IS 2-HR RATED
T S D D
maple
ENGINEERING, pllc
TEMPERATURE SENSOR SMOKE DETS. F 1405 HILLSBOROUGH ST
RISER NOTES: 1. EXISTING FIRE ALARM DEVICES ARE SHOWN IN FAINT. NEW OR PROJECT No.:
RELOCATED DEVICES ARE SHOWN IN BOLD. SEE LEGEND.
D
1301
1. FIRE ALARM SYSTEM IS EXISTING. COORDINATE NEW DEVICES WITH EXISTING FA SYSTEM TYPE, STORAGE
MODEL, AND REQUIREMENTS. PROVIDE ALL PROGRAMMING AND FINAL CONNECTION BY A 2. THE FIRE ALARM CONTRACTOR IS TO BE HELD TO THE SAME 204
FACTORY TRAINED TECHNICIAN. REQUIREMENTS AS THE ELECTRICAL CONTRACTOR. FIRE ALARM
CONTRACTOR SHALL REVIEW ELECTRICAL PLANS AND AH-1
2. EXISTING FIRE ALARM DEVICES ARE SHOWN IN FAINT. NEW OR RELOCATED DEVICES ARE ELECTRICAL "GENERAL NOTES" BEFORE COMPLETING BID.
SHOWN IN BOLD. D
3. FIRE ALARM CONTRACTOR IS TO VERIFY EXISTING FIRE ALARM
3. RISER IS GENERIC IN NATURE. CONTRACTOR TO FIELD VERIFY EXACT LAYOUT AND SYSTEM HAS BATTERY AND VOLTAGE CAPACITY TO HANDLE F
30cd
EQUIPMENT PRESENT. ADDITIONAL DEVICES. PROVIDE FIRE ALARM SHOP DRAWINGS IF
REQ'D TO LOCAL AHJ. LOUNGE
201
FIRE ALARM RISER DIAGRAM 4. AUDIBLE FIRE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE
5 NO SCALE
A SOUND PRESSURE LEVEL OF 15DBA ABOVE THE AVERAGE
AMBIENT SOUND PRESSURE LEVEL AT ALL LOCATIONS WITHIN THE
OCCUPIABLE SPACE. TYPICAL AVERAGE AMBIENT SOUND
PRESSURE LEVELS ARE GIVEN IN NFPA 72 TABLE A-4-3.2.
N
TO
O
L ON
R
TI
A 6. FIRE ALARM DEVICES ARE TO BE INSTALLED IN ACCORDANCE
P
TO
IC R
EN
U
A
N
I
LD NT TR AT
O
E-
LL O L S ST
O
A
D R
R
O
M
IC
TI
IN TO
K
TO HE CE EN ST
WITH NFPA 72 AND 'ADA'.
TO
R FL
IP
TA
A
D
TO
A
M A
M
A
IN
L
R LL EV
EQ
C
A
A
D
L LA
A CA AL L T NTR
IC A
EL
O
A
O A
S
EC
G
N
A
IN
A
O
D N
FL S
R
B
N
N
O
R
C
H
IN G TI
R
L SS M
A
R
S
SI
L
7. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT OR AS ALLOWED CONFERENCE
LI
O
F
TO O
SI
C
A O
IR OR
C
A
LE
L TE
SI
O
N
D
L N RE FR ZA
TO
A Y
R
Y
N
A O I
B
TI
D
G
O
IG
S SU LA AT ION
N R A
TO
SI DD
R
30cd
A
G IGN R
A
BY NEC OR LOCAL AHJ.
EV TI GN NA
VE L D
O N ER
SO
H
203
L
I A U
IS
ER
A
S
A
T
S VI LE E A IZ SS T
S
LE
S
G
S
,D
A
EV
O
A
N
W
VI
R D C ER
T
I
M R
A
TR SM IRE OF CU
R AS RO VIS IG
LL AG LE Y S
TR
M B O E
B
R S
R
L
ST
U VIC SU PR AU
EL
R
E
P
Y
R PE
P
PE
A
R
LA LA
N
A
L
O
A ST
O
M
F
U
ES L
M
E TO
TO L
O
TO
V
I
SU
TI
TR D
SU
O
H
TR
A
O
A
A 8. ELECTRICAL CONTRACTOR SHALL PROVIDE AN UPDATED FIRE
PE R
A R EL EX
H
C
D ITS E D
N R L
G
LE OR
EX
LE LE P
PE
R
N
N VA
A
O TO
IN
N
R RW KE
M UB
O
R
E
K
E
R
B B B
ES
M ALARM LAYOUT PLAN AT THE FACP.
D
I I I O
G
M
O
O I
N
VA
TR AY ENE
M O TA MO
O
D D D N
R
EM
M
M
O U U U
O
A
A
ZO E L
O
N
F
T
C A A A R F S S
H
EL
EX
G
C
LO LL
EL
W
C
IT
IT
T
TE TE TE TE TE ED
E E TE
TE
TE
TE
TE
EC E
EL MI
T T
O
LL
TR M
SH K
T
A A A A A A A A
VA
Y
S
A
C
SE
TU TU TU TU TU A A TU TU TU 9. TESTING OF THE FIRE ALARM SYSTEM SHALL BE THE RESPONSIBILITY
PL
N
TU
TU
TU
TU
T
E
EC EL
TI
A
U
LO
C C C C C C C C
IS
C
C
N
SYSTEM INPUTS A A A A A R D A A A
A
A
D
U
OF THE ELECTRICAL CONTRACTOR.
-
A B C D E F G H I J K L M N O P Q R S T U V W X Y
1 FIRE ALARM SYSTEM AC POWER FAILURE 1
2 FIRE ALARM SYSTEM LOW BATTERY 2 10. CONTRACTOR TO ENSURE ALL EXISTING DEVICES ARE
3 OPEN CIRCUIT 3 FUNCTIONING PROPERLY AND CANDELLA RATING IS AS
4 GROUND FAULT 4 INDICATED. FIRE ALARM PLAN - 2ND FLOOR
5
6
NOTIFICATION APPLIANCE CIRCUIT SHORT
BUILDING MANUAL PULL STATIONS
5
6 2 SCALE: 1/4" = 1'-0"
7 CORRIDOR SMOKE DETECTORS 7
8 AREA SMOKE DETECTORS 8
9 HVAC AIR DUCT SMOKE DETECTORS 9
10 AREA HEAT DETECTORS 10
11 HOOD OR ROOM FIRE SUPPRESSION SYSTEM ALARM 11
12 SPRINKLER TAMPER SWITCH 12
13 SPRINKLER WATER FLOW IN BUILDING 13
14
15
SPRINKLER WATER FLOW IN ELEV EQUIP RM OR SHAFT
ELEV EQUIP RM AREA SMOKE DETECTOR
14
15
FIRE ALARM SYMBOL LEGEND
16 ELEV SHAFT AND ELEV EQUIP RM HEAT DETECTORS 16
17 ELEV LOBBY SMOKE DETECTORS - UPPER FLOORS 17 FIRE ALARM CONTROL PANEL, SEMI-FLUSH MOUNTED.
18 ELEV LOBBY SMOKE DETECTOR - RECALL FLOOR 18
19 ELEV CONTROLLER POWER SHUNT TRIP STATUS 19 AN FIRE ALARM SYSTEM ANNUNCIATOR PANEL, 48" A.F.F.
20 FIRE PUMP POWER FAILURE/PHASE REVERSAL 20
21 FIRE PUMP RUNNING 21 F FIRE ALARM SYSTEM MANUAL PULL STATION, 48" A.F.F.
22 FIRE PUMP SYSTEM NOT IN AUTOMATIC 22
23 LEGALLY REQUIRED GENERATOR SYSTEM LOW FUEL 23
24 LEGALLY REQUIRED GENERATOR NOT IN AUTOMATIC 24
F FIRE ALARM SYSTEM ALARM INDICATING DEVICE, HORN/STROBE, 80" A.F.F. S F F
25 AREA OF REFUGE TWO-WAY COMMUNICATIONS STATUS 25 15cd 15cd
26 - 26 S FIRE ALARM SYSTEM ALARM INDICATING DEVICE, STROBE, 80" A.F.F.
27 - 27
A B C D E F G H I J K L M N O P Q R S T U V W V W F FIRE ALARM SYSTEM ALARM INDICATING DEVICE, HORN/STROBE, CEILING.
MOUNT NOTIFICATION TS FIRE ALARM SYSTEM TAMPER SWITCH. FIELD COORDINATE EXACT QUANTITY AND
MOUNT ON DEVICES ON LOCATIONS.
APPROVED BOX SUPPLY DIFFUSER APPROVED BOXES DINING
OR RETURN/EXHAUST OPENING 6" MIN. FS FIRE ALARM SYSTEM FLOW SWITCH. FIELD COORDINATE EXACT QUANTITY AND LOCATIONS.
SMOKE/HEAT 106
4/21/13
DETECTOR BAR
1'-0" MAX. FIRE ALARM SYSTEM ROOM TEMPERATURE SUPERVISORY SWITCH. ALARM SHALL INDICATE A F
60cd 102
CEILING T
4" MIN. COORDINATE EXACT QUANTITY AND LOCATIONS.
0'-4" MIN. 3'-0" MIN. HORN
EXIT GRAPHIC HORN STROBE STROBE
120V MULTI-STATION SMOKE DETECTOR WITH BATTERY BACK-UP. CONNECT TO NEAREST 120V
ANNUNCIATOR SMOKE/HEAT CIRCUIT. FOR UNITS WITH 2 OR MORE SMOKE DETECTORS, DETECTORS MUST BE INTERLOCKED
SD
DETECTOR SUCH THAT THEY ALL ALARM AT ONE TIME.
"ADA" - UNITS SHALL HAVE 177CD STROBE NOTIFICATION IN SLEEPING AREAS.
FACP
A ANSUL HOOD SYSTEM "ALARM" OUTPUT.
(TOP OF DEVICE)
(BTM OF DEVICE)
DATE: 4/21/13
6'-8" MIN.
FLOOR
FA-01