Customer Maintenance and Daily Log: MLN Block 405, Algeria Operator Training
Customer Maintenance and Daily Log: MLN Block 405, Algeria Operator Training
CUSTOMER MAINTENANCE
AND DAILY LOG
CX501KB7
TRAINING GAS TURBINES
Customer Responsibilities:
1. Operation and running of equipment in accordance
with the Centrax Manuals;
2. Maintenance
- lube oil levels
- compressor washing
- replacement of filters;
3. Record keeping, logging of performance and
reporting;
4. Supply of fuels, fluids, extinguishant, filters, lamps;
5. Fluid analysis - oil and fuel.
DAILY LOG
0.8
0.6
0.4
0.2
0
1
CX501KB7
TRAINING GAS TURBINES
DAILY INSPECTION
Complete daily Log Sheet - this will include looking inside the
unit through the windows provided to check pipework for
security and leaks (air, oil and water)
Check lube oil level
Check all air intakes are free from debris
Carry out a compressor wash - frequency dictated by local
conditions and rate of power loss over time
CX501KB7
TRAINING GAS TURBINES
COMPRESSOR CLEANING
FILTER CHANGING
Oil, Air and Gas Filters are routinely changed under the Centrax
Service Policy however;
If a high differential pressure is indicated on the HMI, the filter
in question is becoming clogged and should be changed - a
sudden increase in differential pressure should be
investigated - and Centrax informed immediately.
The duplex oil filter can be switched over manually when the
differential pressure reaches the alarm level (2 to 3.0 bar g)
The duplex fuel filter can be switched over manually when the
differential pressure reaches the alarm level (2 to 3.0 bar g)
CX501KB7
TRAINING GAS TURBINES
OIL CONDITION