Plano Fuji Yida Nuevo

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

D Main Power Switch (By others) Main Power Switch in M.R.

D
Main Power Supply

K EPS (Emergency Power Supply) Q KMCMain Contactor


PT KDY Running Contactor
LA LA1 L1 U1 2 1 1 2 U3
L1 R R U
L2 V1 YASKAWA V3
LB LB1 4 3 3 4
L2 S S Inverter V
LC LC1 EPS13 L3 W1 6 5 5 6
W3
L3 T T W
H1000
N
N 1 141 +12V
Phase relay short-cricuit signal FR2000-STB TB2 IP
0V
PE ★ 2 116 Y10 Up running
IG
PE J7-1 S1 A
A+ PG
3 GND2 Y11 Down running
J7-2 S2 A-
EPS action signal TB1 B
YJ B+
4 J7-3 Y12 Release S8
B-
C C
J7-7 COM4 SC
J2-2 X11 MB FE

J2-10 X19 M1
B1

Main control board


MC
J3-7 GND2 M2 B2

J7-9 VS A1 Connect when there is a brake unit


31
KLZ + Braking resistor
(+3) +0
J7-10 GND3 32 AC
BU
RZD
J8-1 IP CDBR-4030
(-) -0
J8-2 IG ≧37KW Inverter input power

J8-5 AO 3 4
B IG TB2 S3 B

J8-6 BO SC
IG

Note: when lift has EPS, it should be connected in the main power circuit in serial as above.

A A
Design Draw No. TRA110
Check Sheets 17
Approve
Main circuit
Sheet 1A
Date Remark H1000+Asynchronous motor

FUJI YIDA
1 2 3 4 5 6 7 8

D D
Main Power Switch (By others) Main Power Switch in M.R.
Main Power Supply

Running contactor
K
Main Power Switch (By others) PT
Q KMC Main Contactor KDY
LA LA1 L1 U1 2 1 L1 T1 U3
L1 R R U
LB LB1 L2 V1 4 3 L2 T2 V3
L2 S S V
LC LC1 EPS13 L3 W1 6 5 L3 T3 W3
L3 T T W

N FUJI LIFT Inverter KDY Built-in


N 1 141
+OPC-LM1-PR Not applicable when there is an ELD
Phase relay short-cricuit signal
PE ★ 2 116 FR-2000-STB
PE
PR1卡 Encoder
3 GND2
EPS action signal [P0]
5V
4 YJ Y10 Up running [CM]
GND
J7-1 FWD A-
[PA-]
A+
C Y11 Down running CN2 [PA+] C
J7-2 REV B-
[PB-]
CN3 [PB+]
B+
Y12 C-
J7-3 Release EN [PC-]
C+
PG
[PC+]
D-
[PD-]
D+

Control mainboard
[PD+]
J7-7 COM4 [CM]
CM

Shielded
J2-2 X11 30B
J2-10 X19 Y1
J3-7 GND2 30C
CMY
J7-8 VB 12
J7-9 VS V2
31
KLZ Brake Resistor
J7-10 GND3
32 P
11 P+
B CM B
A+ RZD
J8-7 3
A- DB
J8-8 4 DB
B+ CN4
J8-9 1
B-
J8-10 2

★ Note: when lift has EPS, it should be connected in the main power circuit in serial as above.

A A
Design Draw No. TRA110
Check Main control Sheets 17
Approve circuit Sheet 1F
Date Remark FUJI + synchronous motor

FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

U1 V1 W1

ZDY
13 14
N
ZDY Main power inter-action
D 5 9 D
B5 B6

Phase Relay

KXX

Controller Power Breaker

F13P6A)

R2 S2 T2

TC1 Main control contactor Running contactor Door lock relay Braking contactor
Connect when floor number≥16
Braking contactor
Control power transformer F4(1P4A)
C 103(+) KMC KDY KMB KLZ KJR BK1 BK2 KLZ C
43 44 44 43 1 2 2 1 2 1 Brake 4 3
380V LZ
110VDC 102(-) RJ
RLZ
D1
0VAC 220VAC 0VAC Braking economic resistor
110VAC
d
X23- r
FR-2000-STB

J5-4 101 a
X22- J5-2
FR-2000-STB

o Applicable when brake voltage is DC110V


b
T
A2 A2
o
n 100a
200a KMB KJT i
M
a
a
J5-3
i X23+ X22+ J5-1
m
A1 A1
n
o
T
b
o
F3(1P4A) 116 F2(1P4A)
a
r
d
SMJ
KXX Phase sequence Control power breaker Connect when total floor number≥16
201 200 Main control contactor Running contactor Door lock relay Braking contactor Braking contactor
Car door switch KMC KDY KMB KLZ KJR KLZ
Safety circuit 100 43 44 44 43 2 2 1 2 1 4 3
1
117
141 SDT T2 N
RJ
118 AC AC
Landing door on N floor

SJT Emergency stop in M.R. Emergency stop on car top

Remark
Landing door on 1st floor

SMn Braking economic resistor


B ZL1 B
SM1 105 + -
Landing door on 2nd floor

115a
SMn-1 SDC
Emergency stop in car Brake
SPS Jigger handwheel switch BK1 BK2
LZ
SM2
115 110 106 ★Braking input power ★
SMn-2
GJ DJ SKT
Emergency running Inspection
Emergency stop in pit Remark: The brake voltage is according to the actual.
SM3 SCS Up running overspeed switch When brake voltage is DC220V, rectifier "ZL1" is connected.
Door interlock loop

114a
When brake voltage is AC220V, jump the "ZL1".
SKS Rope break-off switch
Applicable when brake voltage is AC220/DC220V
SXS Speed governor switch
111
114
SNQ Safety gear switch

A SSJ Top final limit A


108 Design Safety, Door Draw No. TRA110
113 Check Interlock, Brake 17
Sheets
SXJ Bottom final limit Approve Circuit Sheet 2
SHC Buffer switch
Date Remark
109
FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

200 201 Connect when there is fire fighting function


For elevator speed≥2.0m/s Fire fighting center

For lift with 6 stop above

Thermal controller constant-close output


2
+24V
DJ Electronic lock
3 1 Inspection box oncar top

Brake detecting switch


Up door zone Locked when Break-off
DMGCOM in Car Top Fire fighting motion
130 Down limit zone 6
Top terminal 2 Bottom terminal 2Top limitBottom limitTop terminal 1 44 44 Red

Opional
SDZ2 XDZ2 SXV XXV SDZ1 Bottom
XDZ1 SMQ XMQ SXF CXF Emergency stop contactor
Brake
limit 1 Fireman switch
Emergency running

Fan: DC24V

WK
GJ KJT KLZ SDF

FAR
D L N FMG COM in M.R. KMB D
Switch power 5 Door interlock 31
2 SMQ XMQ 43
43
+5V -5V +24V-24V KBK1 KBK2

Emergency Running Signal


3 1 KDY Black
32
119 120 121 122 123 124 XF KBK DF WK
FMS FMX DMS DMX
Slow up in M.R. Slow up at car top
YJ
Slow down in M.R.

MS MX
Slow down at car top

+5VGND3 +24VGND3 +24V GND2 X3 X4 X5 X6 X7 X8 X9 X10 X12 X13 X14 X15 X16 X17 X20 X21
X0 X1 X2
J4-4 J4-3 J4-2 J4-1 J3-10 J3-7、8、9 J1-1 J1-2 J1-3 J1-4 J1-5 J1-6 J1-7 J1-8 J1-9 J1-10 J2-1 J2-3 J2-4 J2-5 J2-6 J2-7 J2-8 J3-1 J3-2 J2-9
FR2000-STB
For rear door
J6-10 J6-6 J6-9 J6-7 J6-8 J6-5 J6-1 J6-2 J6-3 J6-4 J5-9 J5-10 J4-5 J4-8 J4-9 J4-10 J4-6 J4-7

COM3 Y6 Y9 Y7 Y8 COM2 Y2 Y3 Y4 Y5 COM1 2H 2L


Y1 1H 1L

A1 A1 A1 A1
Main control contactor

2 KLZ KDY KJR KMC


Running contator

Economic resistor relay

4
Braking contactor

J5-2

J5-3

J5-4
J5-1
C KJT C
KJT
A2 A2 A2 A2
3
1
21 X22+ X22- X23+ X23-
KYJ LD1 LD2
22 116 101 118 101
24T GND1 C+ C- CB+ CB- GND1
6 Connect when there is fire fighting function Safety Detecting Door Lock Detecting
KMB
5
CM1 KM2 GM2 KM GM
Connect when total floor number≥16 Call box/COP Twin control/Group control
116 101 communication wire communication wire

When using Blue Light SJT-FZ,leave them For rear door For rear door
RS-485

24T GND1 C+ C- Serial weighing communication

1KAB2 2KAB2
Spcial use switch Bypass switch By attendant switch
Safety edge1
Safety edge2 RT- RT+ 24V CMM
SZY SZS SZH

B KQZ KKZ KCZ B


KMZ GMV2 KMV2 GMV1 KMV1
Door close limit 1Door open limit 1
Safety edge 2
Light loadNo load Overload Full loadDoor close limit2Door open limit 2 1KAB1 2KAB1
Safety edge1
CMM GMV2 KMV2 GMV1 KMV1 KAB KAB2
QZ KZ CZ MZ

J1-1J1-2 J1-3J1-4 J9-1 J9-8 J9-9 J9-5 J9-6 J10-6 J10-5 J9-3 J9-2 J9-4 J9-7 J10-1 J10-2 J9-10 J10-7 J10-8 J10-9 J10-10

NCZB
J11-1 J11-2 J11-3 J11-4 J11-7 J11-8 J11-5 J11-6 J2-4 J2-3 J2-2 J2-1 J3-4 J3-3 J3-2 J3-1 J4-4 J4-3 J4-2 J4-1 J5-4 J5-3 J5-2 J5-1 J6-4 J6-3 J6-2 J6-1

BLV+ BL1 ZM
yellow 13 +24V +24V +24V +24V
BEL Light control Overload light Door open button2 Door open holding button
+24V
red Door open button Door close button Door close button 2
A KZM CZD SKM1 SGM1 SKM2 SGM2 SKY A
F5(1P4A)
Arrival chime
KMD1 GMD1 KMD2 GMD2 KYD
Design Draw No. TRA110
black Door open light 2
BLV- 14 Door open light Door close light Door close light 2
Check Sheets 17
Approve Control circuit
+
Sheet 3
DC24V N L31 24V CMM BY1 BY2
Date Remark
TC1 Spare output Door open holding light
FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

201 For machine room less elevator U5


U
L31 N
D V V5 Door motor Car top light switch D
200 W5 SDM
W L311 Car top light EDM

Car top socket XD


L 200
FXS Pit light switch
N 201 SKK
L312 Pit light EKM
PE

NCZB COP mainboard Pit lighting socket XK


Shenling VF
Door machine KMV1(5)
B2 J9-2 XG Control cabinet power socket
GMV1(6) Car light
XS1 XS2 B3 J9-3 KZM SJM1 EM
L33 EM1
CMM(4) J9-1
21 22
C2 C3
Car light switch
2 GM(3) Lighting control relay Car light
EM2
Speed governor motion Speed governor reset Car fan switch
1 KM(2)
SFA Car fan
FA FAN
C 8 C
8 CM1(1)

The No. in paranthesis is cable No. of Shenling door machine

Shaft light switch(M.R.) Shaft light switch(pit )


L32 SZMf SZMk N
2 1 1 2 ECM1
U U6

V V6 Door motor Shaft light

W W6
2 3 3 2 ECMn

L 200
N 201
PE Safe lighting breaker
TD3200 VF Q1
B
NCZB L31 B
L3
Door machine
KMV2 J10-5
PC1
N N
GMV2 J10-6
PC2
CMM J9-1
PAC
GM2 Q2
CD L32
KM2
OD
N
CM1 Shaft lighting breaker
COM

A A
Design Draw No. TRA110
Check Sheets 17
Approve Control circuit
Sheet 4
Date Remark

FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

24T
GND1

C+
C-

D 1 D

2
3
4

1
2
3
4

1
2
3
4

1
2
3
4

1
2
3
4
J1

J1

J1

J1

J1
NHTB

NHTB

NHTB

NHTB
NHTB

DZD

DZZ
J2

J3

J2

J3

J2

J3

J2
J3
4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1
Arrival gong output (negtive motivation)
+24V
+24V

+24V

+24V

+24V

+24V

+24V

+24V

-24V
+24V

+24V
C C

Down
Up
BEL

Text
Text
N floor down call N-1floor up call N-2 floor up call 3rd floor up call 3rd floor down call 2nd floor up call 2nd floor down call 1st floor up call Arrival lantern Arrival gong

Elevator A Elevator B
CB+ CB+ Indicator
J4 6 6
CB- CB- J4
BL-2000-STB 7 7 BL-2000-STB
8 GND1 GND1 8 Full load
J4 J4
Inspection

5 8 9 10 5 8 9 10
V+ V- E D C B A S X CZ MZ XF JX
GND1

GND1
Text
C+

C+
24T
C-

C-
24T

B B

1 2 6 7 8 9 10 11 12 14 15 16 17
J5

1 2 3 4 1 2 3 4 BL2000-HXJ-V9
4 4 J3 J2
J1 3 3
J1
Up call J1
J2 2 +24V 2
J2
1 1 Converter board
NHTB NHTB
4 4
3 3
J3 Down call +24V
J3
2 2
A A
1 1
Design Draw No. TRA110
Check Sheets 17
Approve Landing call loop Sheet 5
Date Remark
When two elevator are twin controled and use one common landing call button ,connect the wire as per this drawing
and only connect the parallel wires. FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Indicator
D D

Overload

Fireman

J12 SN9
V+ V- E D C B A S X CZ MZ XF JX 4
SN1 >
4 3

1st floor car call 3


> J1 JE1
2 +24V
9th floor car call
ND1 JN1 ND9
+24V 2 1
1

1 2 6 7 8 9 10 11 12 14 15 16 17
NEB
J5
BL2000-HXJ-V9 SN2 SN16
4 4
J3 J1 J2 Converter Board
3 3
3 4 2 1 16th floor car call
FR2000-STB 2nd floor car call ND2
+24V
2
JN2 JE8 2 +24V
ND16
C J4 GND1
1 > J2 1 C

24T
C+
C-

10 9 8 5
NCZB
GND1

SN3 SN17
24T

4
C+

Optional function
C-

4
3 JN3 3
3rd floor car call ND3
+24V 2 > J1 JE1
2 +24V
17th floor car call
ND17
1 1

NEB
SN8
4 SN24
4
3
8th floor car call ND8 JN8 3
+24V
2 JE8 +24V
24th floor car call
2
ND24

B
1
> J2 1
B

>
GND
C+
+24

C-

4 3 2 1
J1
FR2000-CZB
COP 1 2 3 4 1 2 3 4
J10
7 8 9 10 J1 Terminal
CMM

Voice announcer
RT+
24V
RT-

Car indicator

A A
Design Draw No. TRA110
Weighing
Check Sheets 17
Approve Car call loop
Sheet 6
Date Remark

FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

F7 AVR2 BL2000-QKB
(4A)
L1 L 0V
J1-3

Group control board


AC220V
N N +5V J1-4
D D
FR-2000-STB FR-2000-STB FR-2000-STB

J4-6 1H J1-6 J4-6 1H J4-6 1H

1L 1L 1L
J4-7 J1-7 J4-7 J4-7
J4-8 GND1 J1-8 J4-8 GND1 J4-8 GND1

GND1

GND1

GND1
CB+
CB-

CB-

CB+

CB-
CB+
Elevator A Elevator B Elevator H

Group control system loop:

The terminal can be placed near to the control cabinet


Suggest that there be no radiation equipment nearby
SJT-WJ Monitor center 1
FR2000-STB SJT-WK
C 4 +5V 5V C

8 GND3 GD DC5V/1.5A Power


J4 C+
9 H
Wireless remote control system loop:
10 C- L
SJT-WJ Monitor center 2
Wireless network

DC5V/1.5A Power
Control cabinet

FR2000-STB SJT-YCJ
GND3
BL2000- YH H
3 3 YXZDB 6
4 +5V 4 7 YL L
Wire remote control system loop: J4 Monitor center
9 C+ 9
J1 J1 8 YG G
B B
10 C- 10
Network
(Every control cabinet use one of this)

Control cabinet Note:one monitor system use one data collector


Power it can monitor several elevators.

FR2000-STB SJT-QIC/QID
GND3
BL2000- YH H
3 3 KIC/KID 6
IC/ID card management system loop : 4 +5V 4 7 YL L IC card reader
J4 Monitor center MF-500
9 C+ 9
J1 J1 8 YG G
GC-1 10 C- 10
1 2 3 4 Network
(IC/ID card network controller )
ID card reader
GND1
24T

C+

Control cabinet
C-

YX-K4-232
A A

Power
Design Draw No. TRA110
1 2 3 4 Check Sheets 17
J2 Optional function loop
Approve Sheet 7
BL2000-CIC/CID
Car IC/ID controller Date Remark
FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D D

FR2000-STB SJT-ZPC-V2
JP1-1
J4-2 +24V
K10 K11
12 11 21 22 K14
JP1-2
J3-7 A1 A2 D5
GND2 21 22
J3-8 K12 11 K11 12 K12
J3-9 D1
64 61
21 K10 22 R1 C1
Advance door opening /releveling door zone switch

LS1 K12
ZPS 44 41
JP1-3 A1 A2
K10 K10
Up releveling door zone input 44 41 D2

Advance door opening /releveling LS2 K12


relay output ZPX 31 32
J5-10 COM1 JP1-4 A1 A2
K11 K11
C Down releveling door zone input 31 32 D3 C

Y0 J5-8 JP1-5 A1 A2
Y0
K14
D2
Advance door opening /releveling relay K12 K14 K10 K11
output signal test J3-3 JP1-6 21 22 34 33 31 32 41 44

JP1-7

K10 K11
Releveling door zone signal inputJ3-4 JP1-8 54 51 61 64

JP1-9
K12 K14 K10 K11
SMn 117 SMJ 116 Door Lock
JP1-10 11 12 44 43 61 64 51 54

B B
Optional Function: Advance door opening and Releveling SM1 118 Door Lock JP1-11

A A
Design Qian Jianqiang Draw No. TRA110
Check Advanced Door Sheets 17
Approve Opening Sheet 8
Date 2013.10.1 Remark

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Monitor Room E. Power

+ +
NKT12(1-1)16N--59N(Main)
Emergency Power Box - -
M.R. Car Top Pit Car
Alarm E. Light Intercom A- AR AL AD1 AD2 AC AC
D AC220V + - + - + - - R L - R L - R L EB1 EB2 + - R L D
+ + +
From main intercom to pit of lift #1
RVVP 0.75*5 AC220V
Alarm

EYJ

Call
JL+ JL1 A- AR AL AD1 AD2
P+
+
P- -
R Adapter
L31 N R
L
L
(Lift 1#)
A- AR AL AD1 AD2

C C

Emergency Power Box From lift #1 to pit of lift #2


M.R. Car Top Pit Car RVVP 0.75*5
Alarm E. Light Intercom
AC220V + - + - + - - R L - R L - R L EB1 EB2 + - R L
+ + +
Alarm

EYJ

Call
JL+ JL1
A- AR AL AD1 AD2
P+
+
P-
-
R Adapter
L31 N R
L
L
(Lift 2#) A- AR AL AD1 AD2

B B

From lift #2 to pit of lift #N


RVVP 0.75*5

Intercom bus cable by others and


A- AR AL AD1 AD2
Emergency Power Box layout should be reasonable)
M.R. Car Top Pit Car
Alarm E. Light Intercom +
AC220V + - + - + - + - R L + - R L + - R L EB1 EB2 + - R L - 1, cable is RVVP 0.75*5
Adapter
R 2, single bus should not bifurcation or star wiring
Alarm

EYJ

L 3, Intercom should be connected to its own adapter.


Call

JL+ JL1 A- AR AL AD1 AD2


P+
A A
P- Qian Jianqiang
Design Draw No. TRA110
R Check Optional Function Sheets 17
L31 N
L Approve Sheet 9
NKT12 Intercom(bus connection)
Date 2013.10.1 Remark
(Lift N#)

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Monitor Room
E. Power

+ +

Emergency Power Box - -


M.R. Car Top Pit Car
Alarm E. Light Intercom AC AC
AC220V + - NKT12(1-1)6A--64A(Main)
D
+ - + - + - R L + - R L + - R L EB1 EB2 + - R L D
E.Power above 32 by own
AC220V
Alarm

EYJ

Call
JL+ JL1

P+
P-
-
R R1
L31 N
L
L1

(Lift 1#)

C C

Emergency Power Box


M.R. Car Top Pit Car
Alarm E. Light Intercom
AC220V + - + - + - - R L - R L - R L EB1 EB2 + - R L
+ + +
Alarm

EYJ

Call
JL+ JL1

P+
P-
-
R
L31 N R2
L
L2

(Lift 2#)

B B

Intercom bus cable instruction:

1:Each one connect one communciation cable to monitor room


2:Cable is RVVP 0.75*4

Emergency Power Box


M.R. Car Top Pit Car
Alarm E. Light Intercom
AC220V + - + - + - - R L - R L - R L EB1 EB2 + - R L
+ + + -
RN
Alarm

EYJ

LN
Call

JL+ JL1

P+
A P- A
Design Qian Jianqiang Draw No. TRA110
R
L31 N Check Optional Function Sheets 17
L
Approve NKT12 Intercom Sheet 10
(Lift N#) Date 2013.10.1 Remark

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Emergency Power Box Car Top Pit


M.R. Car
Alarm E. Light Intercom
AC220V + - + - + - - R L R L R L R L
+ EB1 EB2
D Alarm
D

EYJ NBT12Intercom E. Power

Call
JL+ JL1
+ +
P+
- -
P-
- AC AC
R
L31 N R1
-
R2
(Lift 1#) AC220V

Above 32 by own

-
RN
C Emergency Power Box C
M.R. Car Top Pit Car
Alarm E. Light Intercom
AC220V + - + - + - - R L R L R L R L
+ EB1 EB2
Alarm

EYJ

Call
JL+ JL1

P+
P-
R
L31 N

(Lift 2#)

B B

Intercom bus cable instruction:


1:Each one connect one communciation cable to monitor room
Emergency Power Box
Alarm E. Light Intercom
M.R. Car Top Pit Car 2:Cable use twisted-pair,wire diameter 0.75square,2 cores
AC220V + - + - + - - R L R L R L R L
+ EB1 EB2
Alarm

EYJ

Call

JL+ JL1

P+
P-
A A
R Design Qian Jianqiang Draw No. TRA110
L31 N
Check Optional Function Sheets 17
Approve Sheet 11
NBT12Intercom
(Lift N#)
Date 2013.10.1 Remark

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D D

DC110V output EPSS-EPB110/220 JT-04A1 JT-2000C


IC Card Control IC Card Control
220V Input DC12V output
J22 J1 J8
Yellow TerminalsJ1 J2 J3 J4 J5 J6 P1 P2 P4 P5 P6 P7
24+ 24- OUT1+ 0UT1- 24+ 24- 1 2 3 4 1 2 3 4
- + - +
Jump it for use 21
KJT
22
+ - 24T GND1 24T GND1
optional

T2 N BK1 BK2 B5 B6
116 118
Leveling Zone SN1 SN8
MQ1 4 4

F1 Car Call 3 3
When MRL lift has "advance door ND1 JN1 JN8 +24V F8 Car Call
open" or "releveling" function, this 2 2
wiring should not done. ND8
Power DC12V 1 1
C C

Video Cable SN2


4
SN9
3 J12 J1 4
LCD indicator in Controller To monitor machine in shaft F2 Car Call ND2 JN2
2 > 3
F9 Car Call
1 > JE1 2 +24V
ND9
1

Applicable for MRL lift with EMK electric brake release and machine monitor function CZB
SN3
4
3 JN3 Note: when JT-2000C is applied,the connection of wire 3 &4 between .
F3 Car Call ND3
+24V extension card and IC card controller should be reverse
2
When JT-04A1 is applied, instruction on CZB board should be
1
connected to OUT1,instruction on extension board should be
connected to OUT2.

B B
SN4
4
3
F4 Car Call ND4
+24V
JN4
Emergency Power Box M.R. Car Top Pit Guard Room Car Inside 2
Alarm E.Light Intercom
AC220V + 1
- + - + - + - R L R L R L + - R L Red BlackYellowBlue

14
Alarm

Call
EYJ

BJ
13
JL+ JL1
P+
P-
R
L31 N

BJ
B5 B6 (Jingke 5-party intercom)
5 9
A Remark:BJ (inter-action for alarm is optional) A
Design Qian Jianqiang Draw No. TRA110
Check Opional Function Sheets 17
Approve Intercom,Electric Sheet 12
Brake Release
Date 2013.10.1 Remark

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

200

D
Top final limit switch SSJ
D

100

Top limit switch SSV

Top terminal switch SSD *1

Top sub-terminal switch SSD2 *2

200
Bottom final limit switch SXJ

Bottom limit switch SXV


C C
100

Bottom sub-terminal switch SXD2


*2

Bottom terminal switch SXD


*1

Leveling position SMQ XMQ


H
Leveling zone switch SMQ XMQ Car

(Unit:mm)
Shelter board
H1

B B
UP DOWN

ELevator have to finish hoistway learning before high speed running.


The conditions below are neccesary before hoistway learning:
1.Top/bottom limit switch and top/bottom terminal switch are installed ,connection is correct. Speed
2.Up/down leveling zone switch and shelter board are installed ,connection is correct. Item 0.5m/s 1.0m/s 1.6m/s 2.0m/s 2.5m/s
3.Safety circuit and door interlock circuit are normal. *1 1000 1300 2500 2500 2500
4.General parameters and running parameters have been set. *2 4000 6250
5.Elevator can perform inspection running. H 180 180 230 230 230
6.If inverter is YASKAWA G7 and above 18.5KW ,please check if the junction of inverter braking unit in the H1 200 200 250 250 250
bottom left corner of the control cabinet is on 415V(Open the grey cover).
Before hoistway learning, the system should be in inspection state and elevator should press the bottom limit
switch.If elevator don't located at the bottom limit position,"To Down Limit"will be displayed
Press slow down button as to move the elevator to bottom limit.If elevator is at bottom limit and " Enter To Start" is
displayed(Elevator State:Up leveling zone X9 is valid,down leveling zone X10 takes off from
shelter board ),press "Enter" key,elevator starts to perform hoistway learning(Elevator state : bottom limit X6
is reset ,then down leveling zone X10 come into the leveling zone).Hoistway learning stops at
A A
top limit (Elevator state:when arriving the top floor , up leveling zone X9 takes off from shelter board ,then top limit Design Draw No. TRA110
switch act )."Success" will be displayed if hoistway leaning is finished successfully.Please strictly
Check Signal collection Sheets 17
perform hoistway learning according to the steps above ,otherwise hoistway learning may fail."Failure LER=#" will
Approve system Sheet 13
be displayed if there is a fault,you should solve the problem by fault code at first.
If you want to escape from hoistway learning ,press "Esc" key,then "LER=15" displayed. Date Remark
FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

CB2
GC-4
Control cabinet
GC-7 CB3
D GC-1 GC-2 GC-3 D

Terminal CB5 CB5 CB5 Car top junction box Car top inspection box
XDZ
SDT Door operator cable Power terminal
No. Mark 100 1 2 TB7 DDZ
1 L31 DC-1 DC-2 DC-3 105 1 116
JL+ No. Mark
2 L32 1 L31 1 24T 1
130 2 117 1 U1
2 JL1 DMS
3 N 2 L31 2 GND1 3 3 200 2 V1
C+ 3 GND2/
4 GND2 3 N 3 2
1 DMX
4 201 3 W1
5 121 Limit 4 N 4 C- 4 DJ
5 CMM 4 N
6 122 5 L33 5 105 5 110
6 GMV1 5 U3
7 116 6 6 L313 6 111
7 KMV1 6 V3
Door interlock 7 7 EM 7
8 117 MX 8 KAB 7 W3
9 118 8 8 FA 8
MS 9 KM
9 8
10 100 9 200 9 CMM

COP cable CB9


C EDM 10 GM 9 C
11 114 10 201 10 KMV1 10 SDM
Safety DC-9 L31 XD 11 CM1 10
12 115a 11 100 11 GMV1 11
N 12 (E)
13 115 DC-10 12 106 12 KAB 12
13
14 130 Inspection 13 108 13 BL1 13
SMQ SMQ
15 DF Electronic lock DC-11 14 110 14 CZ 14
XMQ XMQ
16 B1 15 111 15 MZ 15
GND2 WECO light curtain
B2 16 Door operator cable1 connection
17 16 116 16 +24V CB8
B3 17 17 111 SNQ
18 17 117 KMV2 No. Mark Remark
Intercom 1 117A
18 GMV2 18 107 1
19 18 GND2
2 117
GND2 19 KAB2 19 108 SNC 2 CMM Signal
20 19 3 200
Brake detection 20 3 KAB
21 BKB 20 130 20 CM1
4 201
21 MZ KMZ 4 200
22 WK Temperature Detection 21 MS 21 KM2
5 CMM
CZ KCZ 5 PE
23 BK1 22 MX 22 GM2 22 Power
Brake 6 GMV2
23 CMM 6 201
24 BK2 23 SMQ 23 B1
B 7 KMV2 B
25 201 24 XMQ 24 B2 24 EM EM1
Optional 8 KAB2
26 XS1 25 BLV- 25 B3 25 EM2
For machine room less and 9 KM2
27 XS2 two direction speed governor 26 BLV+ 26 B4 26
FA
FAN 10 GM2
28 GND1 27 ZM 27 B5 27
11 CM1
29 CB+ twin control 28 CM1 28 B6 28 N
12 (E)
30 CB- 29 KM 29 29
JL1 ALARM 13
30 GM 30 30
JL-

Note: when lift has "advance door open" function, B5 should be connected to ZPS, B6 connected to ZPX.
NKB24A DC24V When MRL lift has "electric brake release" function, B5, B6 should be connected to level zone switch.
Arrival Gong

Leveling Sensor +24V GND T1 T2(action)


A Blue(-) Brown(+) Black(signal) A
Design Draw No. TRA110
Check Sheets 17
SMQ/XMQ

Approve Car top circuit Sheet 14


GND2

+24V

Date Remark
BLV+

BLV-

BL1

FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Control Cabinet

Hoistway cable CB3


GC-7 200 201 GC-4
2 nF
24*0.75+1*2.0mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5
D Wire No.in D
Plug No. drawing Cable No. CB1
1 L31 1
114
2 N 2 Pit 113 SSJ
3 P+ 3 121 HTB
GND2 SXV
Plug (171830-1) Pin(170308-1)

4 P- 4 J1
123
5 119 5 Top terminal 2 GND2 SDZ1
CH-4
6 121 6 Top limit 119
GND2 SDZ2
7 123 7 Top terminal 1

8 120 8 Bottom terminal 2 117 Applicable when speed above 2.0m/s


Control cabinet

NKTM nth floor door lock


9 122 9 Bottom limit
GC-7 E
10 124 10 Bottom terminal 1 L N
171364-1 IN:AC220V Note: when floor/stop number is more than 28,
11 GND2 11 please cut the power cable 24T in the middle and
3KTM Power Unit
12 108 12 Bottom final limit 2KTM OUT:DC24V extend another branch cable(length:2m) from the
3th floor door lock second power unit in shaft , wire no. 24Ta, GND1.
E V- V+
13 114 13 Top final limit
C C
14 117 14 2KTM
Door interlock 24Ta
15 118 15 1KTM 2nd floor door lock
E
16 XF 16 Fire switch GND1 2F
17 DF 17 Electronic lock 1KTM
Olivine 118 1st floor door lock
18 E Earthing
E
19 111 19 Applicable when speed above 2.0m/s
Pit emergency
106 stop 120
20 20
GND2 XDZ2
21 R 21 HTB
124 J1
L 22 Intercom GND2 XDZ1
CH-4
23 122
GND2 XXV
24
108
109 SXJ
DF 1F
GND2 DF
B Landing call serial communication cable XF B

2*2P*0.75 CB2 spare


GND2 SXF

Wire No. in Wire No. in


Plug Pin No. drawing Cable No. drawing Pin No. Plug
E 111106
Control cabinet

L31 N 109 113


Plug(1-480705-0)

1 24T 1 24T 1 Light and socket in pit Buffer SHC Pit emergency stop SKT and rope breakage switch SKS
HTB
2 GND1 2 GND1 2 J1
GC-4 CH-4 CH-4
1-480704-0 3 C+ 3 C+ 3
4 C- 4 C- 4
5 E Shield E
when lift has through open (double door),HOP wires at the sub-door side should be
connected to HOP wires at main door side in parallel .

HOP Power Cable CB1


2*0.75
A Dwg No. Wire No. Dwg No. A
Design Draw No. TRA110-B
200 1 200
Check Sheets 17
201 2 201
Approve Hoistway circuit Sheet 15
Note: CB1 is only applied when the floor/stop is more than 28, the cable are with number tube at two ends, length is half shaft height plus 5m.
Date Remark

FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Traveling cable CB5 COP cable CB9


36*0.75+4 core shield 19*0.75+9*0.75+(2*2p)*0.75
Wire No. in Wire No. in Wire No. in Wire No. in
Plug Pin No. drawing Cable No. drawing Pin No. Plug Plug Pin No. drawing Cable No. drawing Pin No. Plug

1 24T Shield 1 24T 1 1 24T shield 1 24T 1


DC-1 JC-11
Plug(1-480705-0)

Plug(1-480705-0)

Plug(1-480705-0)

Plug(1-480705-0)
D
GC-1 2 GND1 shield 2 GND1 2 DC-11 2 GND1 shield 2 GND1 2 D
1-480704 1-480704 1-480704 1-480704
3 C+ shield 3 C+ 3 3 C+ shield 3 C+ 3
4 C- shield 4 C- 4 4 C- shield 4 C- 4
5 E shield E 5 5 E shield E 5
1 +24V white 1 +24V 1 1 CMM white 1 CMM 1
2 GND2 white 2 GND2 2 2 KMV1 white 2 KMV1 2
3 130 white 3 130 3 3 GMV1 white 3 GMV1 3
MS KAB
Control cabinet

4 MS 4 4 4

Car top
white 4 KAB white 4

Plug(172347-1)Pin (170308-1)
Plug(172347-1)Pin(170308-1)

Plug(172347-1) Pin(170308-1)

Plug(172347-1)Pin(170308-1)
5 MX white 5 MX 5 5 CZ white 5 CZ 5

Car top
GC-2 DC-10

COP
6 SMQ white 6 SMQ 6 6 MZ white 6 MZ 6
171358-1 171358-1
7 XMQ white 7 XMQ 7 7 KAB2 white 7 KAB2 7
8 CM1 white 8 CM1 8 8 KMV2 white 8 KMV2 8
C DC-2 JC-10 C

9 KM KM 9 171358-1 9 GMV2 white 9 GMV2 9 171358-1


white 9
GM GM BLV+ BLV+
10 white 10 10 10 white 10 10
BLV- BLV- BL1
11 white 11 11 11 BL1 white 11 11
BLV+ BLV+ N
12 white 12 12 12 N yellow 8 12
13 ZM yellow 12 ZM 13 13 ZM yellow 9 ZM 13
1 100 orange 1 100 1 1 white 12 1
2 106 orange 2 106 2 2 white 13 2
3 108 orange 3 108 3 3 B1 white 14 B1 3
4 110 orange 4 110 4 4 B2 white 15 B2 4
5 111 orange 5 111 5 5 B3 white 16 B3 5
6 116 orange 6 116 6 6 B4 white 17 B4 6
B B

7 117 orange 7 117 7 7 YJ+ white 18 YJ+ 7


8 L31 orange 8 L31 8 8 YJ- white 19 YJ- 8
N
Control cabinet

9 N orange 9 9 9 9
Car top

GC-3 10 L33 L33 10 DC-9 10 10


Plug(171830-1) Pin(170308-1)

orange 10
Plug(171830-1)Pin(170308-1)

DC-3 JC-9
Car top
Plug(171830-1)Pin(170308-1)

Plug(171830-1)Pin(170308-1)
171364-1 171364-1
11 KM2 yellow 1 KM2 11 171364-1 11 11 171364-1

COP
Orange 11、12 earthed
Orange 11、12 earthed

12 GM2 yellow 2 GM2 12 12 12


13 yellow 3 13 13 105 yellow 1 105 13
14 200 200 14 14 yellow 2 106 14
yellow 4 106
15 201 yellow 5 201 15 15 L33 yellow 3 L33 15
16 B1 yellow 6 B1 16 16 FA yellow 4 FA 16
17 B2 yellow 7 B2 17 17 EM yellow 5 EM 17
A A
18 B3 yellow 8 B3 18 18 JL+ yellow 6 JL+ 18 Design Draw No. TRA110-B
JL1 Check Sheets 17
19 B4 yellow 9 B4 19 19 JL1 yellow 7 19 Traveling cable
Approve Sheet 16
20 B5 yellow 10 B5 20 20 20 Date Remark
21 B6 yellow 11 B6 21 21 21 FUJI YIDA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

JC11
Pin No. Wire No.
24T
Plug(1-480705-0)
1
Plug(350536-1)

2 GND1
3 C+
D 4 C- D
5 (E)
6 TVVP4

JC10 1 2 3 4 1 2 3 4
Pin No.Wire No. J2 CH-4
1 CMM J9-1
2 KMV1 J9-2 J1 Car indicator
IC Card Reader
3 GMV1 J9-3 Open door 1 J1
KMD1
4 KAB J9-4 2
Plug(172347-1)Pin(170308-1)

J6-1 CH-4
5 CZ J9-5 3 J2 KYD
J6-2 1 2 3 4
6 MZ J9-6 SKM1
7 KAB2 J9-7 CZB 4 J6-3
J6-4 SKY
8 KMV2 J10-5
J10-6 Door open delay
9 GMV2 Close door
10 BLV+ J11-1 GMD1 1 J10-7 RT-
11 BL1 J11-2 2 RT+
12 N J11-3 3 J3 J10-8 RS-485
SGM1 J10-9 CMM Serial load communication
13 ZM J11-4 4
C C
J10-10 24V

JC09
Pin Wire No. EYJ Emergency Light CMM
1
1 YJ+ YJ+
2
CZB-01 J9-1
2 YJ- YJ- J10-1 SZY Special
3 J4
J10-2 SZS Bypass
4
SZH By attendant
J9-10
For rear door if any
1
1 2 ND1
2 JN1 3
1st floor car call
3 J5 SN1
4
Hands-free Intercom 4
(COP)
B1 Call Button
3 B1 +
B2 1
4 B2 - Red ND8
B3 2 8th floor car call
5 B3 R Black JN8 3
Plug(171830-1) Pin(170308-1)

B B4 B4 L B
6 SN8
4

J1
J12
CZB-EB
J2
9
10
11
J1
12
105 SDC Emergency stop in car
13 105
14 106
106 CZB-EB
15 L33 J2
L33
FA SFA Fan
16 FA
EM SJM1
17 EM
18 JL+ JL+
19 JL1 JL1 JL
A 20 Alarm A
21 Design Draw No. TRA110
Note: Check Sheets 17
1. After the COP wiring is finished ,the plug should be made by the drawing. Approve COP wiring Sheet 17
2. The drawing is for BEST intercom ,Laogang intercom has different wire connection
,wire No. B1-B6. Date Remark
FUJI YIDA
1 2 3 4 5 6 7 8