Port
Solenoid
Valves
Standard Specifications
Housing Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Others
See Selection Guide (p.66-70).
Ambient Max. 50℃ (Temperature may differ depending on coil and fluid temperature. See p.76 for details.)
temperature Min. –17℃ (Temperature may depending on seat materials. See p.76 for details.)
25
Zero-differential Pressure Pilot-acting 2-port Solenoid Valves
Insulation class
( mm
)
(W)
( Rc
)
Max.
( )V
Cv value
50/60Hz
Housing
℃
Orifice size
Voltage
Port size
Air/
Min.
※
Normally closed De-energized Energized
type
3/8 15.9 3.3 0 0.96 0.61 0.96 0.61 0.61 0.48 50 A 10 10 F 100 YS201AF88N5CG4 YS201AF88J7CG4
1/2 15.9 4.1 0 0.96 0.61 0.96 0.61 0.61 0.48 50 A 10 10 F 100 YS201AF88N5DG4 YS201AF88J7DG4
3/4 19.1 5.5 0 0.96 0.61 0.96 0.61 0.61 0.48 50 A 10 10 F 100 YS201AF88N5EG5 YS201AF88J7EG5
YS
20
1 25 11 0 0.68 − 0.34 − − − 50 A 10 − F 100 YS201AF88N5FG9 YS201AF88J7FG9
type
3/8 15.9 3.3 0 1.37 0.86 1.37 0.86 1.37 0.86 50 A 11 10 F 100 YS202AF88N5CG4 YS202AF88J7CG4
1/2 15.9 4.1 0 1.37 0.86 1.37 0.86 1.37 0.86 50 A 11 10 F 100 YS202AF88N5DG4 YS202AF88J7DG4
3/4 19.1 5.5 0 1.37 0.86 1.37 0.86 1.37 0.86 50 A 11 10 F 100 YS202AF88N5EG5 YS202AF88J7EG5
※Max. fluid temperature(℃) may differ depending on the type of fluid. See p.76 for details.
*Mark:The maximum operational pressure difference is 1.0MPa ,in case of operating system of a manual.
26
Model Code
1 2 3 4 5 6 7 8 9 10 11
Y S 2 0 1 A F 8 8 N 5 C G4
1 2 3 4 5 6
Notes:5)
Connection Housing Coil
Series Valve type Rated voltage
type type Insulation
88=AC100V
(50/60Hz)
・
A = Conduit
AC110V
P = Open frame (60Hz)
B = Grommet
T = Conduit with terminal box 94=AC200V
YS
(50/60Hz)
X = NEMA 4,7drip-/explosion-
・
20
proof AC220V
G = NEMA 4 drip-proof (60Hz)
with terminal box
J = Explosion-proof enclosure 02=AC110V
(50Hz)
(d2G4) (conduit)
・
K = Explosion-proof enclosure Class F AC120V
1= Normally closed (d2G4) (60Hz)
(pressure-resistant packing) ClassH
C = Explosion-proof enclosure 04=AC220V
(Exd Ⅱ BT4) (conduit) (50Hz)
・
E = Explosion-proof enclosure
AC240V
(Exd Ⅱ BT4)
(60Hz)
(pressure-resistant packing)
16=DC24V
25=DC100V
No entry =NPT
88=AC100V
(50/60Hz)
・
A = Conduit AC110V
(60Hz)
P = Open frame
B = Grommet 94=AC200V
(50/60Hz)
T = Conduit with terminal box ・
X = NEMA 4,7drip-/explosion- AC220V
proof (60Hz)
G = NEMA 4 drip-proof 02=AC110V
with terminal box Class F (50Hz)
J = Explosion-proof enclosure ・
2= Normally open AC120V
(d2G4) (conduit) ClassH
(60Hz)
K = Explosion-proof enclosure
(d2G4) 04=AC220V
(50Hz)
(pressure-resistant packing) ・
C = Explosion-proof enclosure AC240V
(Exd Ⅱ BT4) (conduit) (60Hz)
E = Explosion-proof enclosure
16=DC24V
(Exd Ⅱ BT4)
(pressure-resistant packing) 25=DC100V
18=DC120V
97=DC125V
27
Zero-differential Pressure Pilot-acting 2-port Solenoid Valves
7 8 9 10 11
Notes:2) Notes:4)
C=3/8 G4=15.9
D=1/2
E=3/4 G5=19.1
N = Nitrile rubber
5 = Brass K = Mounting bracket
V = Fluorine rubber
F=1 G9=25.0 ● Not applicable for
YS
C = Ethylene
valve port size Rc1
propylene
20
or larger.
rubber G=1_1/4
H=1_1/2
J2=32.0 M = Manual operating
5 = Bronze J=2 system
● Not applicable for
valve port size Rc1 or
larger and normally
C=3/8 G4=15.9 open valves with
D=1/2
housing J, K, C, or E.
J = Nitrile rubber
E=3/4 G5=19.1 N = Neon lamp
L = Fluorine rubber (with surge absorber)
E = Ethylene 7 = Stainless steel
● Applicable for valves
propylene with housing T, G
F=1 G9=25.0
rubber
Z = Surge absorber
● Applicable for valves
G=1_1/4 with housing T, G, J,
H=1_1/2 J2=32.0
K, C, or E.
J=2
Explosion-proof
enclosure
C=3/8
G4=15.9 Applies only to coil
D=1/2
insulation(H).
N = Nitrile rubber
V = Fluorine rubber For hausing(C,E)
C = Ethylene 5 = Brass
C = China
propylene ● Applies only to
rubber valve type(1).
E=3/4 G5=19.1
H = Korea
For hausing(Y)
None = ATEX guidelines(EU)
● Applies only to
valve type(1).
C=3/8
G4=15.9 W = CNS(Taiwan)
D=1/2
J = Nitrile rubber ● Applies only to
valve type(1).
L = Fluorine rubber
E = Ethylene 7 = Stainless steel
propylene O = Oil-free
rubber
E=3/4 G5=19.1
28
Structure / Operation
YS
20
Issuance 37 30 43 37
Apparent E(3/4) 1.0 0.9 0.9 1.0 1.2 1.2 1.6 1.7 1.9
power
(VA) Brass (5)
Retention 22 15 24 18
F(1) 1.8 1.8 1.8 1.9 2.0 2.1 2.4 2.5 2.7
AC 10 11 G(1_1/4)
Power 2.7 2.7 2.7 2.8 2.9 3.0 3.3 3.4 3.6
consumption H(1_1/2)
(W)
DC 10
Bronze (5) J(2) 4.1 4.1 4.1 4.2 4.3 4.4 4.7 4.8 5.0
E(3/4) 1.0 0.9 0.9 1.0 1.2 1.2 1.6 1.7 1.9
Stainless F(1) 1.9 1.8 1.8 1.9 2.0 2.1 2.4 2.5 2.7
(7)
steel
G(1_1/4)
2.9 2.8 2.9 3.0 3.1 3.2 3.5 3.6 3.8
H(1_1/2)
J(2) 3.4 3.3 3.3 3.4 3.6 3.6 4.0 4.1 4.3
29
Zero-differential Pressure Pilot-acting 2-port Solenoid Valves
G1/2
Depth 10
YS
20
Dimensions Unit : mm
A B
Body Port size(Rc) C J K E F H
NC NO NC NO
● Valves with manual operating system C、D(3/8・1/2) 99 110 57 59 14 6 44 70 56 35
〔Normally closed〕Size for valves with manual operating system is 18 mm larger. 5 (Brass)
E(3/4) 104 115 60 62 16 9 47 70 56 35
〔Normally open〕 See P.71 for manual operating systems.
Normally closed
G1/2
Depth 10
Dimensions Unit : mm
A B
Body Port size(Rc) C E F H
NC NO NC NO
F(1) 130 − 80 − 21 92 82 45
5 (Brass)
G.H(1_1/4.1_1/2) 146 − 89 − 28 110 92 55
5 (Bronze) J(2) 160 − 93 − 38 140 92 65
30
External Dimensions
Dimensions for conduit housing(A)
G1/2
Depth 10
YS
20
Dimensions Unit : mm
A B
Body Port size(Rc) C J K E F H
NC NO NC NO
● Valves with manual operating system C、D(3/8・1/2) 98 109 57 59 13 6 44 70 56 35
〔Normally closed〕Size for valves with manual operating system is 18 mm larger. 7 (Stainless steel)
E(3/4) 107 118 60 62 19 9 47 70 56 35
〔Normally open〕 See P.71 for manual operating systems.
G1/2
Depth 10
Dimensions Unit : mm
A B
Body Port size(Rc) C E F H
NC NO NC NO
F(1) 130 − 80 − 21 92 82 45
7 (Stainless steel) G.H(1_1/4.1_1/2) 149 − 89 − 31 110 92 55
J(2) 160 − 93 − 39 140 92 65
31