Touch Panel Display VT5 Series Vision System XG/CV-X Series Touch Panel Display VT5 Series Vision System XG/CV-X Series
Touch Panel Display VT5 Series Vision System XG/CV-X Series Touch Panel Display VT5 Series Vision System XG/CV-X Series
×
Vision System XG/CV-X Series Connection Guide
Vision System XG/CV-X Series Connection Guide
×
Touch Panel Display VT5 Series
Preface Overview of Connection Between Vision System and VT5 Series Supported units (vision systems)
Step 1 Checking the Equipment Required for Vision System Monitoring
XG-X Series
Step 2 Connection Procedure for Vision System Monitoring
Troubleshooting XG-8000/7000 Series
CV-X400/X100 Series
Extra 1 Placing a Vision System Monitor Part on the Operation Screen
Extra 2 Placing a Video Display Part on the Operation Screen Supported units (touch panel displays)
VT5 Series
Preface
Overview of Connection Between Vision System
and VT5 Series
With the VT5 Series, you can display images from vision systems or check their settings in two ways: via “vision system monitor connection” using
Ethernet cables and via “RGB connection” using an RGB cable.
Connection diagram
Ethernet
switch
Ethernet * Only for the VT5-X. RGB connection cannot be used for the VT5-W.
Features: Features:
• Multiple vision systems can be connected only using LAN cables. •O ne VT5-X Series display can be connected to one vision system
(Up to 32 units) via an RGB cable.
* Both VT5-X and VT5-W can be used.
• Y ou can check or change settings of a vision system using the
• You can check or change settings of a vision system using the console or mouse connected to it.
USB console or mouse connected to the VT5 or through touch
operation. • T he video update cycle is faster compared to that via vision system
monitor connection.
2
VT5×XG/CV-X Connection Guide
Step 1
Checking the Equipment Required for
Vision System Monitoring
Prepare the following equipment and wire them by referring to the connection diagram:
VT5 Series*1: 1 unit Vision system: 1 unit LAN cable: 1 unit Ethernet switch*2
STP/UTP cable
*1 Both VT5-X and VT5-W can be used. *2 Not required for direct connection to the VT5 Series.
Connect the Ethernet port of the VT5 Series to the vision system as follows:
STP/UTP cable
One Point
Multiple vision systems can be connected using an Ethernet switch. (Up to 32 units)*
. . .
* Although up to 32 units can be connected, only four of them can be monitored at the same time.
3
VT5×XG/CV-X Connection Guide
Operate the VT5 Series to use vision system monitoring via Ethernet connection.
The procedures in this guide describe connection procedures using VT STUDIO Ver. 6.01 and VT5 main unit system program Ver. 2.01. If you are using earlier
versions, please update them in advance. Also note that the IP address of a vision system is assumed to be “192.168.0.10” (default). To change the IP address, refer
to “Reference: When Setting the IP address of a Vision System Manually.”
1 Switch to system mode on the VT5 main unit. Press and hold on a place where no touch switches are located on the screen.
After some buttons appear, touch the [System Mode] button.
2 Under [System Mode], select [VT Machine Setup] -> [Ethernet Setup] to set the IP address.
(In the example below, the IP address is set to “192.168.0.11.”)
3 Next, select [Tool] under [System Mode], and then select [Vision System Monitoring].
4
VT5×XG/CV-X Connection Guide
5 Specify the monitor No. of the vision system displayed on the search results. The monitor No. will be switched every time
you press the [Unselected] button.
One Point
One Point
5
VT5×XG/CV-X Connection Guide
7 Conduct monitoring on the vision system monitor’s dedicated system screen. The vision system monitor’s dedicated
system screen supports the following functions with an operation panel:
• Selects and displays the connection destination from the vision systems that have been registered for monitoring.
• Switches between one-screen and four-screen displays.
• Saves the displayed image.
One Point
You can use the full-screen display for each monitor No. by touching the number on the operation panel.
The four-screen display can also be used by touching the [All] button.
One Point
You can move the operation panel area to a desired position or minimize/maximize it.
6
VT5×XG/CV-X Connection Guide
Reference
When Setting the IP address of a Vision System
Manually
This section describes the procedure to set the IP address of a vision system manually. (Example of the XG-X Series)
1 If the main unit is not in setup mode, use the No.1 (FUNCTION) button on the console to open the [Function] menu, and then
select [Change to Setup Mode]. When using touch operation on the VT5 Series, touch the screen to display a touch menu.
Then, touch the [To Setup Mode].
One Point
Setting item Setting value
192.168.0.10 (default)
IP address Ensure that the IP address is not the same as that • After you change the
of the VT5 or PLC.
Subnet mask 255.255.255.0 (default)
Ethernet settings, you need
Default gateway 000.000.000.000 (default) to restart the vision system.
Enable BOOTP Cleared (default)
• After you change the IP
Port (Command & Data Output) 08500 (default)
Port (PC Program) 08502 (default) to 08504 address, conduct search
Start Delimiter None (default) again on the [Search] screen
End Delimiter CR (default)
Use individual delimiters per function Cleared (default)
under System Mode.
CV Compatible Trigger Response Cleared (default)
7
VT5×XG/CV-X Connection Guide
Troubleshooting
On the VT5 Series, I cannot switch to system mode because the system menu does not appear even after
Q I press and hold on a place where no touch switches are located.
Q Can I set the IP address of the VT5 Series only under System Mode?
A It can also be set from VT STUDIO. In VT STUDIO, select [Resource] -> [VT setting] -> [Ethernet/Language/Video] to set it.
If I select [Tool] under [System Mode], and then select [Vision System Monitoring], a message “The “Use vision
Q
system for monitoring” setting is disabled” appears and I cannot move to the vision system’s monitor screen.
A In VT STUDIO, you need to select the [Use vision system for monitoring] check box and transfer the screen data to the
VT5 Series. In VT STUDIO, select [Resource] -> [Periphery connection] -> [Vision system monitor] and then select the
[Use vision system for monitoring] check box.
Even if I open “Vision System Monitoring” under System Mode on the VT5 Series and push the [Search] button
Q
on the [Search] screen, no vision systems appear on the search results.
A Check the following:
• Check if the VT5 Series and the vision system are connected via Ethernet.
• Check if the IP addresses of the VT5 Series and the vision system belong to the same network group.
8
VT5×XG/CV-X Connection Guide
Extra 1
Example of Setting to Place a Vision System
Monitor Part on the Operation Screen
The vision system monitor function available via Ethernet connection can be displayed in two ways: on the system mode screen and on the operation screen.
In order to monitor a vision system on the operation screen, you need to place a vision system monitor display part on the base screen in VT STUDIO.
2 Select the “Display area size” and the “Display mode,” and then click [Vision system monitor setting].
You can select the display mode from the following:
•O
ne-screen display
•T
wo-screen display
•F
our-screen display
* You can operate a vision system only when “Single screen display” is selected.
Select this check box when you are connecting a USB console (or USB mouse) to
the VT5 Series to operate vision systems.
(This is only enabled when the “Display area size” is “1024 × 768,” “800 × 600,” or “640 × 480.”)
3 Enter the IP address of the vision system that you will connect and the monitor number of the vision system monitor display
that you will use.
Setting item Setting value
Connection object quantity 1
Sensor 0 settings
Monitor No. Monitor 0
IP address 192.168.0.210
Controller name Arbitrary value
One Point
9
VT5×XG/CV-X Connection Guide
The following functions are restricted when vision system monitoring is used on the VT5 Series:
■ XG-8000/7000 Series
● R estrictions when a USB console is used
On the USB console connected to the VT5 Series, the following operations and functions are disabled, unlike a case where the
console is connected directly to the XG-8000/7000 Series:
Console operation Function
Press and hold on the No. 3 (TRG) button Function to issue triggers repeatedly
Press and hold on the No. 7 (rear) button Function to display the whole flow view
Key repeat by pressing and holding on the No. 1 (FNC) or No. 7
Function to switch the order of the selected item repeatedly
(rear) button + Up/Down key
■ CV-X100 Series
● R estrictions during touch panel operation
On the VT5 Series, the following mouse operations and functions cannot be used through touch operation, unlike a case where a
dedicated mouse (OP-87506) is used:
Mouse operation Function
Displaying the context menu
Click the right button
Switching the full-screen/menu display
Moving/resizing
Setting the imaging range
Adjusting the upper/lower limit bar
Drag the left button
Drawing (rectangle/circle/ellipse/circumference/arc/polygon)
Adjusting the area
Deleting an arbitrary position
Capturing the screen/switching accounts/resetting/resetting the trigger/
Press and hold on the right button
removing SD Card 2
Press and hold on the left button Moving the scroll bar repeatedly
Drag the left button Moving the scroll bar
On the VT5 Series, the following operations and functions are disabled, unlike a case where touch panel CA-MP120T is used:
Touch panel operation Function
Zooming in/out the image
Pinch-in/pinch-out * You can still zoom in/zoom out images by operating a button on the
View bar.
10
VT5×XG/CV-X Connection Guide
Extra 2
Example of Setting to Place a Video Display Part
(RGB Connection) on the Operation Screen
In order to display video on the operation screen through RGB connection to a vision system, you need to place a video display part on the base screen in
VT STUDIO.
One Point
11
www.keyence.com
Copyright (c) 2018 KEYENCE CORPORATION. All rights reserved. VT5CVXGXCONNECT-WW-TG-GB 1028-1 600P96