Professional Documents
Culture Documents
Technical Offer For Gearless Passenger Lift: LG Elevator Co,. LTD
Technical Offer For Gearless Passenger Lift: LG Elevator Co,. LTD
LTD
Detailed Specifications:
A. General:
Manufacturer: LG Elevator Co,.Ltd.
Quality, Safety Certification:
ISO 9001, ISO 14001, OHSAS 19001
Safety Standard: EN91.1, BS & JIS
Lift Series: (Gearless) Principal Stranded
Lift Type: Electric Passenger Lift , Traction type, Microprocessor
based controller operated Closed-loop AC Variable Voltage
Variable Frequency (ACVVVF) drive.
Quantity: 1 (One) units.
Capacity: 630 Kg.
No. of stops: 4 Stops
No. of Services: 4 Services
Travel: 27.25m; or as available
Hoist way inside Dimension: 1800 mm x 1700 mm (W x D), as available
Overhead Clearance: 4500 mm or as available
Pit Depth: 1500 mm or as available
Machine room location: Mini Machine Room. Above the Lift Shaft
Speed of Elevator: 1.0 meter per second.
Power Requirement: AC 400V ± 10%, 3 Phase, 4 wire + earthing, Main Power;
AC 220V 10%, 1 Phase, 2 wire, Lighting.
Battery Back-up: 60 minutes battery back-up for Emergency light, Alarm and
Intercom system in case of power failure (1 extra unit
Supplied as spare.
B. Control & Drive Equipment:
Drive System: LG Elevator Closed-loop, Alternating Current, Variable Voltage,
and Variable Frequency (ACVVVF) Drive.
Machinery: LG Elevator 3-phase electric motor coupled with Reduction gear
unit and Traction sheave.
Motor Rating: LG Elevator 190 Start/Hour heavy-duty commercial grade motor
for round the clock operation. Gearless Torin
Drive Motor.
Control System: LG Elevator Microprocessor based Controller operated,
Selective Collective (FULL COLLECTIVE), SIMPLEX Operation
Controller: LG Elevator series LEHY-III elevator controller has been
Designed around 40396 microprocessor which makes the system
calculate faster and richer selection for field programming. The
controller adopts new network control technology. CPUs are
installed on each landing and car, which greatly reduces the
connection lines and interfaces among all the parts and makes the
system control more efficient and accurate. The printed circuit
boards in the controller adopts lower energy consumption
integrated SMD components and most worldly advanced surface
mounted technology to reduce the area of the PCB and power
consumption of the components and prolong the operation life of
the components.
Diagnosis program and backup system configured among
computers confirm the high reliability of communication among all
elevator parts. The software with logical calculation function is
installed in each computer which greatly enhances human-elevator
interface.
H. Safety Devices:
1) Terminal Limit Switches at Top and Bottom beyond normal travel of lift car
2) Terminal Final Limit Switches at Top and Bottom
3) Car Stop Switch at Inspection Panel on top of Cabin
4) Double electric contacts at Car door and each Landing Doors
5) Door coupling device for synchronization of car door with all landing doors
6) Door Lock Contacts at all Landing Doors
7) Release facility of Door lock contacts from outside for emergency rescue operation
8) Full Height Photocell Operated Door re-open facility at Car Door
9) Door Re-open facility from inside the car and from any landings
10) Adequate Safety feature in Door Hanging Device
11) Over-speed Safety Governor
12) Safety Governor Electric Switch
13) Progressive safety gear (Emergency Safety Locking Device) to lock lift cabin with guide
rails in case of over-speed and torn rope situation
14) Electro-mechanical operated Brake in Machine operating at zero-speed of lift (when lift
comes to a standstill) ensuring jerk-free stopping and securing lift from skidding.
15) Brake release mechanism at top floor Landing Station for emergency manual rescue
operation.
16) Buffers for Car and Counterweight in pit to absorb shock if for any reason lift over travels in
any direction
17) .Over Load Safety Operation
18) Safety door edge on the leading edge of the cabin door.
19) Hand rail on the rear side of the cabin wall.
20) Safe landing operation.
21) Next landing operation.
22) Emergency Car light.
23) Emergency alarm bell.
24) Re-open with hall call button operation.
25) Automatic door open time adjustment.
26) Automatic door speed control.
27) Independence service.
28) Car call registered light.
29) Hall call registered light.
30) Half back wall mirror.
31) All relevant safety features as per EN91.1 Lift Regulation
Repeated door close: In case the elevator doors cannot be closed completely due to some
obstacle, the doors will repeat its door closing actions to take off the
obstruction.
These two features eliminate 95% of all un-necessary breakdown of the lift
Operation thus reducing down time of lifts to a minimum.
B) OTHER DETAILS 30 days
i) Offer Validity: 3 Month from contract date and receipt of first payment.
ii) Manufacture Lead 1Month
Time: iii) Vessel Sailing
Time: iv) Installation and 1Month
Commissioning: 4 Month.
v) Total Duration: (Conditions: Payment terms are maintained and site
is ready for installation and commissioning before
arrival of cargo)
Shaft and Machine Room construction, machine room slab, pit, electrical mains
vi)Exclusions: connection up to machine room, shaft dividing beams (if required), Scaffolding,
mains circuit breakers, lights for the shaft and machine room, centering of
entrance doors in each floor as per layout drawings, any civil construction and/or
modification of shaft for proper installation of lift.
To be made available at site near the work area prior to arrival of lift cargo.
vii) Store Room:
Available for minimum 25 years
viii) Spares:
1 year comprehensive warranty from the date of commissioning of the lift.
ix) Warranty:
1 year free maintenance and after-sale service from the date of running of the
x) After-sale Service: lift. After the free maintenance period, maintenance will be provided by the
supplier at a mutually negotiated price.