Professional Documents
Culture Documents
Strada Socoleni 5,6
Strada Socoleni 5,6
Author
Project: Str.Socoleni 5/6
Variant: New simulation variant
PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6
Project summary
Geographical Site Situation Project settings
Rîşcani Latitude 47.06 °N Albedo 0.20
Republic Of Moldova Longitude 28.85 °E
Altitude 81 m
Time zone UTC+2
Meteo data
Rîşcani
Meteonorm 8.0 (1991-2014), Sat=100% - Synthetic
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 48 units Nb. of units 1 Unit
Pnom total 25.92 kWp Pnom total 30.0 kWac
Pnom ratio 0.864
Results summary
Produced Energy 33.60 MWh/year Specific production 1296 kWh/kWp/year Perf. Ratio PR 84.94 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / -8 ° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer CSI Solar Manufacturer Huawei Technologies
Model CS6W-540MS Model SUN2000-30KTL-US
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 540 Wp Unit Nom. Power 30.0 kWac
Number of PV modules 48 units Number of inverters 3 * MPPT 33% 1 unit
Nominal (STC) 25.92 kWp Total power 30.0 kWac
Modules 3 Strings x 16 In series Operating voltage 250-950 V
At operating cond. (50°C) Max. power (=>40°C) 33.0 kWac
Pmpp 23.69 kWp Pnom ratio (DC:AC) 0.86
U mpp 604 V
I mpp 39 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 254 mΩ Loss Fraction -0.6 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6
Main results
System Production
Produced Energy 33.60 MWh/year Specific production 1296 kWh/kWp/year
Performance Ratio PR 84.94 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6
Loss diagram
1314 kWh/m² Global horizontal irradiation
+16.1% Global incident in coll. plane
PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6
Special graphs
Daily Input/Output diagram