PVsyst - Simulation report


Grid-Connected System

Project: Str.Socoleni 5/6


Variant: New simulation variant
No 3D scene defined, no shadings
System power: 25.92 kWp
Rîşcani - Republic Of Moldova

Author
Project: Str.Socoleni 5/6
Variant: New simulation variant

PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6

Project summary
Geographical Site Situation Project settings
Rîşcani Latitude 47.06 °N Albedo 0.20
Republic Of Moldova Longitude 28.85 °E
Altitude 81 m
Time zone UTC+2

Meteo data
Rîşcani
Meteonorm 8.0 (1991-2014), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 30 / -8 °

System information
PV Array Inverters
Nb. of modules 48 units Nb. of units 1 Unit
Pnom total 25.92 kWp Pnom total 30.0 kWac
Pnom ratio 0.864

Results summary
Produced Energy 33.60 MWh/year Specific production 1296 kWh/kWp/year Perf. Ratio PR 84.94 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6

03/02/22 PVsyst Licensed to Page 2/6


Project: Str.Socoleni 5/6
Variant: New simulation variant

PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / -8 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer CSI Solar Manufacturer Huawei Technologies
Model CS6W-540MS Model SUN2000-30KTL-US
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 540 Wp Unit Nom. Power 30.0 kWac
Number of PV modules 48 units Number of inverters 3 * MPPT 33% 1 unit
Nominal (STC) 25.92 kWp Total power 30.0 kWac
Modules 3 Strings x 16 In series Operating voltage 250-950 V
At operating cond. (50°C) Max. power (=>40°C) 33.0 kWac
Pmpp 23.69 kWp Pnom ratio (DC:AC) 0.86
U mpp 604 V
I mpp 39 A

Total PV power Total inverter power


Nominal (STC) 26 kWp Total power 30 kWac
Total 48 modules Nb. of inverters 1 Unit
Module area 123 m² Pnom ratio 0.86

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 254 mΩ Loss Fraction -0.6 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): User defined profile

10° 20° 30° 40° 50° 60° 70° 80° 90°


0.998 0.998 0.995 0.992 0.986 0.970 0.917 0.763 0.000

03/02/22 PVsyst Licensed to Page 3/6


Project: Str.Socoleni 5/6
Variant: New simulation variant

PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6

Main results
System Production
Produced Energy 33.60 MWh/year Specific production 1296 kWh/kWp/year
Performance Ratio PR 84.94 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh ratio
January 34.9 20.46 -1.74 58.3 57.3 1.411 1.377 0.910
February 51.7 32.98 -0.29 71.4 70.0 1.712 1.673 0.904
March 99.6 46.45 4.89 130.1 127.8 3.055 2.988 0.886
April 136.0 68.63 11.00 153.0 149.9 3.493 3.416 0.862
May 178.5 82.87 17.20 184.9 181.2 4.105 4.013 0.837
June 190.5 78.50 20.63 189.6 185.7 4.156 4.062 0.827
July 194.0 78.08 23.03 195.3 191.5 4.238 4.143 0.818
August 165.8 71.59 22.86 181.2 177.7 3.933 3.845 0.819
September 120.1 48.39 16.61 149.8 146.9 3.338 3.265 0.841
October 78.0 37.60 10.43 109.7 107.6 2.520 2.463 0.866
November 37.4 22.66 5.54 57.9 56.8 1.349 1.315 0.876
December 27.5 18.86 0.42 44.8 43.8 1.065 1.037 0.894
Year 1314.1 607.06 10.95 1526.0 1496.1 34.375 33.596 0.849

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

03/02/22 PVsyst Licensed to Page 4/6


Project: Str.Socoleni 5/6
Variant: New simulation variant

PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6

Loss diagram
1314 kWh/m² Global horizontal irradiation
+16.1% Global incident in coll. plane

-1.96% IAM factor on global

1496 kWh/m² * 123 m² coll. Effective irradiation on collectors

efficiency at STC = 21.15% PV conversion

38.85 MWh Array nominal energy (at STC effic.)

-4.39% PV loss due to irradiance level

-5.06% PV loss due to temperature

+0.55% Module quality loss

-2.10% Mismatch loss, modules and strings

-0.97% Ohmic wiring loss


34.37 MWh Array virtual energy at MPP
-2.25% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.01% Night consumption
33.60 MWh Available Energy at Inverter Output
33.60 MWh Energy injected into grid

03/02/22 PVsyst Licensed to Page 5/6


Project: Str.Socoleni 5/6
Variant: New simulation variant

PVsyst V7.2.6
VC0, Simulation date:
03/02/22 11:41
with v7.2.6

Special graphs
Daily Input/Output diagram

System Output Power Distribution