Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 10

WARRANTY REGISTRATION CARD Instruction Manual

Date of Purchase / / MoviCool


Model :
Mobile :
Name : Address: E-mail :
MAX&DUOS
Condition of Warranty SERIES
We extend this limited warranty to the original buyer (first retail purchaser) and warrant that the product shall be free
from manufacturer defects in workmanship and materials for 12 months from the date of purchase. 1) Warranty will
come in with effect when the following conditions are met with: a) Warranty registration card duly filled and received
by the company within 15 days from the date of purchase, b) Product is operated following all the recommendations
explained inside the user manual. 2) The compan/s liability under the warranty will be limited only to company
supplied motor, Louver motor, Receiver, Remote control, PCB board, contactor, relays, inlet valve, Drain valve, Water
level sensor ,UV light, pump, fan blade and blower and also restricted to any such defect which occurs under conditions
of normal operations and under proper use. Any part/s replaced by the company at its discretion shall be functionally
operative. 3) This warranty shall not apply to product: a) Which have not been purchased from authorized distributor
through their network or compan/s authorized retail stores, b) Which have been altered / opened by any other personnel
not authorized by the company, c) Incorrectly used in combination with any other substance or products,
d) Which are not being installed by company authorized sales and service dealer in accordance with 'Owner's Manual1
e) Fault which develops due to faulty care or maintenance and alterations to product or its parts, f) Which is subjected
to electrical supply for which the product is not designed, g) Warranty will void if the product is operated at incorrect
voltage or frequency or with a sub-standard inverter or non-sine wave inverter, h) If documentation of buying is not
available to validate an original purchase. 4) While the company will make every effort to carry out the repairs at the
earliest, it however is made expressly clear that the company is under no obligation to do so in a specified period of
time. 5) This warranty shall automatically terminate on the expiry of the warranty period of 12 months from the date of
purchase even if the product may not be used for any time during the warranty period for any reason whatsoever. 6)
Cooling pads and all metal parts and plastic parts are not covered under warranty. 7) The company shall not be liable in
any case, for any loss or damage caused to any property, death or disability caused to any human life arising out of fire,
electrical fault, short circuit, accidental handling or any kind of natural calamity. 8) Change of address of the customer
must be intimated to the company without which the warranty shall not be operational. 9) Due to ongoing research and
development, the company holds the right to modify the product without any prior notice or obligation t o buyers. 10)
Purchaser should retain the purchase bill as evidence of the date of purchase. 11) During the warranty customer is not
entitled for any exchange of product or refund of money. 12) The court/ Consumer forums only at Ahmedabad, Gujarat,
India shall have exclusive jurisdiction for any disputes arising out of this sale/transaction. 13) Warranty outside India
will be given by local distributor only. 14) To register service request in India you may call us on 07930130111 or you
may log on to com/care or you may SMS <name, city, pincode, sr.no.> to 09510170111.

SYMPHONY LIMITED
Symphony House, FP12-TP50 Bodakdev, Off SG
Highway, Ahmedabad 380054, India. Email -
services@symphonylimited.com

Evaporative Air Cooler


MoviCoolMAX125
MoviCoolMAX125T
MoviCoolMAX180
MoviCoolMAX180T
Our company reserves the right to make alternations to specifications, quantities, dimensions etc.
For production or other reasons, subsequent to publication. MoviCoolDUOS125
The information contained herein has been prepared by qualified experts within our company.
While we believe the information is accurate and complete, we make no warranty or representation for any particular
MoviCoolDUOS125T
purposes. The information is offered in good faith and with the understanding that any use of the units or accessories in
breach of the directions and warnings in this document is at the sole discretion and risk of the user. READ AND SAVE THIS INSTRUCTIONS MANUAL
9. Trouble shooting Content
Cause Solution Content
tart 1 .No electricity 1 .Check electrical supply
2. Blown fuse 2. Change the fuse
3. Switch is -OFF" 3. Switch on the unit
4. Motor overheating 4. Call a qualified electrician
5. Wiring failures/short circuit 5. Call a qualified electrician
g 1 .Lack of ventilation 1 .Open doors/windows to improve
ventilation
2. Air outlet incorrectly directed or 2. Remove the interference source
positioned
3. Air filter and/or evaporative panel 3. Replace the air filter and/or
clogged with dust evaporative panel
4. Distributor clogged or broken 4. Unclog or replace the distributor
5. Insufficient water flow through 5. Check the pump, make sure the
panels hose is not bent
6. The pump does not work 6. Call a qualified electrician
7. The water feed piping is loose 7. Check for leaks, inspect seals
8. The pump filter is clogged/dirty 8. Replace pump filter
9. The inlet water filter is clogged or 9. Clean inlet water filter and be sure
the check valve is installed that check valve is installed
incorrectly correctly
or
1. Motor overload
1. Call a qualified electrician
2. Air circulation is insufficient
2. Open doors/windows to increase
ventilation
3. Evaporative panels are obstructed
3. Clean or replace evaporative panels
or dirty

f 1. The fan blades are misaligned 1. Call a service technician

1. Foreign parts inside the casing 1. Check and remove foreign parts
2. Unbalanced or misaligned fan 2. Call a service technician
blades
3. Loose parts or screws 3. Check and tighten screws

1. Stagnant water in the tank 1. Drain, wash and clean tank


2. Air filter clogged or dirty 2. Replace air filter
Note: this list is only for reference. Shall you need any
assistance, please contact one of our dealers.

Disclaimer --------------------------------------------------------------1
General Safety Information ------------------------------------------2
Product Description ---------------------------------------------------3
Specifications and Dimensions---------------------------------------3
Installation---------------------------------------------------------------4
Fix water pipe as necessary-------------------------------------------5
Operation----------------------------------------------------------------5
Maintenance and Cleaning--------------------------------------------7
Wiring diagram---------------------------------------------------------8
Trouble shooting -----------------------------------------------------11

Instruction Manual 11
Ouroampeny roso/ves the right to mate alterations to spocfflcMona, quantities, etc. forpmducOon or otlter reasons, aubsequent to publication.
Disclaimer MoviCoolDUOS125T:
Our company reserves the right to make alterations to specifications, quantities, dimensions etc. for production or other
reasons, subsequent to publication.
The information contained herein has been prepared by qualified experts within our company.
While we believe the information is accurate and complete, we make no warranty or representation for any particular Rotary switch(UP)
purposes. The information is offered in good faith and with the understanding that any use of the units or accessories in
breach of the directions and warnings in this document is at the sole discretion and risk of the user.

Important
Read and save this instruction. Read carefully before attempting to assemble, install, operate or maintain the
product. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage. Retain this instructions for future reference.
This symbol indicates this product should not be disposed with other household waste throughout the
EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your used
device, please use the return collection systems or contact the retailer were the product was purchased.
They can take this product for environmental safe recycling.

Instruction Manual Instruction Manual 10

Rotary switch(DOWN)

MoviCoolDUOS125:

o O

M L
H C C
Power Cool Swing Water

o o Fan/U
oo
Fan/D

oo Co
Speed
ol
亘 同
ON/
Swing
OFF
巨 回

n, U/D
Fan
AC power
Ouroampeny resetves the right to maits alterations to ^tocfflcMons, quantities, eto. forpmducOon or other reasons, subsequent to publication. o Hi O Our company reserves the righttomaim alterations to specflfcaitons, quantffioa. etc. for production cr ether reasons, subaequent to pubHcation.

If the power supply cord is damaged, it must be replaced by a qualified person in order to avoid a hazard.
1.6 Do not insert any objects into the air inlet or outlet, as bodily injury or property damage may occur.
1.7 Do not operate this product near an open flame orthe product may ignite and cause fire, resulting in bodily injury or property damage.
1.8 Do not operate in areas where gasoline, paint or otherflammable liquids or vapors are used or stored.

A WARNING
Before to cleaning or maintenance, the air cooler must be unplugged.
1.9 Always unplug the power cord from the receptacle when the air cooler is not in use, before adding water, before cleaning, before replacing parts, or before moving to another location.
1.10 Do not use this appliance in the immediate surroundings of a bath, a shower or a swimming pool or other liquids.
1.11 Do not plug the cord into electric outlet with wet hands or an electric shock may result.
A WARNING
To reduce the risk of fire or electric shock, do not use this Evaporative Cooler with any solid state speed control device.
1.15 Use only on GFCI (Ground Fault Circuit Interrupter) protected receptacles.

Instruction Manual 2
Our company roserves the righttomaico alterations to specflfcaitons, quantffies. etc. for production cr ether reasons, subaequent to pubHcation.

A WARN I 回
Stagnant water may cause bacterial growth and serious health problems. Do not allow stagnant water to
remain in the tank.
1.12 During regular use, fully drain the tank and renew the water every day.
1.13 Drain and clean the water tank before storage, after seasonal use and whenever the unit is not in daily use.
1.14 Never attempt to disassemble or alter the product in any way not instructed by this manual. Shock, fire, or
bodily injury may occur.

Instruction Manual
2. Product Description 7.8 Cleaning inner parts
The Evaporative Air Cooler is an efficient, energy-saving product. It cools by combining water evaporation with Clean the fan blades, float ball valve, water tank, water level sensor, water pump and drainage
air movement, through carefully designed and manufactured equipment, providing maximum efficiency and plug.
safety.
The evaporative cooling technology is very economical and gives a number of additional benefits compared to
traditional air conditioning systems for homes and businesses. The system does not use refrigerants or
compressors; it cools by simply moving air through a surface composed of specially designed evaporative
panels.
Heat from the inlet air is absorbed by the water. The resulting outlet air temperature drops when the water
transforms into gas. Humidity is not perceived since the air in the room is renewed approximately every two
minutes, while a comfortable cooling effect is created. Continuous air circulation is a vital aspect of the Fan Blades--------
evaporative cooling process used in this equipment, which gives it a distinct advantage over air conditioning by
refrigeration.
Float Ball Valve ——

3. Specifications and Dimensions Water Tank-------


Water Level Sensor---------
Model MoviCoolMAX125 MoviCoolMAX180 Water Pump--------
MoviCoolMAX125T MoviCoolMAX180T
Max Airflow 9000m3/h

Voltage 220~240V 50Hz/220~240V 60Hz/100-127V60Hz


Drainage Plug
Power Consumption 250W

Noise Sound Pressure 8. Wiring Diagram


Level (Low-High 64dB(A)
Speed, 1m) MoviCoolMAX125 & MoviCoolMAX180:
Net Weight 23.5kg 29.5kg

Tank Capacity 125L [33 gal] 180L [47 gal]

Model MoviCoolDUOS125 MoviCoolDUOS125T

Max Airflow 18000m /h


3

Voltage 220-240V 50Hz/220-240V 60Hz/100-127V60Hz

Power Consumption 425W

Noise Sound Pressure


Level (Low-High 68dB(A)
Speed, 1m)
Net Weight 39.5kg

Tank Capacity 125L [33 gal]

Note:
1.If the product you bought is different with specification, standard shall be object to the real fitting. 2.
If your power supply type not show in this list, please check the data label on the unit.
Instruction Manual
Our company reserves the righttomaim alterations to specflfcaitons, quantffioa. etc. for production cr ether reasons, subaequent to
pubHcation.
A WARNING Model A B D E
c
Stagnant water may cause bacterial growth and serious health problems. Do not allow stagnant water to remain in the tank. MoviCoolMAX125
During regular use, fully drain the tank and renew the water each day. 33.9(860) 56.1 (1425) 20.9(530) 22.8(580) 22.4(570)
MoviCoolMAX125T
Drain and clean the water tank before storage, after seasonal use and whenever the unit is not used for more than one week.
MoviCoolMAX180
Maintenance is key for your cooler to have an effective and long service life. Keep your unit in good condition to avoid unnecessary parts replacement. 33.9(860) 65.4(1660) 20.9(530) 22.8(580) 22.4(570)
MoviCoolMAX180T
7.1 Be sure to shut down and unplug the cooler before performing maintenance or cleaning. MoviCoolDUOS125
33.9(860) 85.8(2180) 20.9(530) 22.8(580) 22.4(570)
7.2 Completely drain the tank by removing the drain plug from the base and opening the drain valve. MoviCoolDUOS125T
Note: All dimension are in Inches(mm).
7.3 Remove the two screws on the top of the cooling pad panel and gently pull off the panel.

7.4 once a week. Use a soft cloth or soft plastic bristle brush and water only, remove the accumulated dust and debris.

7.5 The evaporative cooler pad should be rinsed with gently running water only.

7.6 Close the drain valve and reinstall drain plug and the cooling pad set after finishing maintenance.

7.7 Cleaning the cooling pad:

MoviCoolMAX125 MoviCoolMAX180 MoviCoolDUOS125


MoviCoolMAX125T MoviCoolMAX180T MoviCoolDUOS125T

4. Installation
Take out the unit carefully from package, check the product, if any part is damaged, contact with the sales agent
immediately.
Before use this product, the product need installation the product as below photo:

Wash the cooling pad with fresh running water. Do


not use high pressure water. Do not use acid or No. Description Quantity
7.8Put out the filter net. alkaline chemicals. 1 Wheel with brake 2
7.9 Lift the cooling pad gently Clean the inlet air filters every week or more 2 Water tank bracket 2
and pull out to remove it. often in dusty conditions. 3 Screws ST5 *25 32
4 Wheel without brake 2
Instruction Manual Instruction Manual
5.Fix water pipe as necessary Light (LED) indicators:
High/Middle/Low^ 辟釦 light shows the currently set airspeed level.
Water inletA: Water inlet B:
PowerQ: light is on when the unit is powered.
Cool 椎:light is on when the unit is working in cooling mode.
SwingO: light is on when the vertical louvers are oscillating.
Shortage of Water U: flickers or keeps on when water level in the tank is below minimum.
Fan running status (MoviCoolDUOS) : light shows the currently set running fan.

Pushbuttons (keys):
• On/Off: Press the ON/OFF button to start the unit Press the ON/OFF button again if the "Standby” mode
is needed.

• Wind Speed: Set the desired air flow speed of the Evaporative Cooler by pressing the "Wind Speed"
button, the indicator light will show "High”, “Middle” or xtLow" accordingly.

• Cool: Press the COOL key during the standby 0 mode. The cooling indicator light will stay on, then flash,
the pump will start and then the machine will start. This will take approximately 30 seconds.
• Swing: Press the SWING button to start or stop the vertical louvers from oscillating.

6. Operation • Fan U/D(only MoviCoolDUOS): Press the button to switch up/down fan.
The following functions are available both on the main control panel of the unit and on the remote control:

Alarms:
• Water Shortage Alarm: If the water level in the tank goes below minimum the Evaporative Cooler will
beep and the "SHORTAGE OF WATER" light will flicker. If the water level is not brought back up to
the normal level after 15 seconds, the “SHORTAGE OF WATER" light will keep on, the pump and the
cooling will shut off.
Note: The Fan and Swing will still remain operable when the Cooling is shut off.

• Rotary switch: The switch(UP) is for operating pump and swing, switch(Down) is for Operating fan and
select the speed of fan.

Remote Control
The remote control has the same features as the control panel on the unit.

Batteries: The Remote Control requires (2) AAA Batteries.

MoviCoolMAX12 MoviCoolDUOS125 MoviCoolMAX125T MoviCoolDUOS12


5 T (UP) MoviCoolMAX180T 5
MoviCoolMAX18 MoviCoolDUOS125T(DOWN)
0

Instruction Manual Instruction Manual 6


Ouroampeny roso/ves the right to mate alterations to spocfflcMona, quantities, etc. forpmducOon or otlter reasons, aubsequent to Our company msorvos (fie right to make alterations to spedficationa, quanOttes, etc. fof production or othor reasons, subsequent to
publication. pubVcatfon.

You might also like