Professional Documents
Culture Documents
Split Type Air Conditioner (50Hz) : Indoor Unit Models Outdoor Unit
Split Type Air Conditioner (50Hz) : Indoor Unit Models Outdoor Unit
Split Type Air Conditioner (50Hz) : Indoor Unit Models Outdoor Unit
CONDITIONER (50Hz)
DUCT type
CONTENTS
SPECIFICATIONS .......................................................................... 1
CIRCUIT DIAGRAM ....................................................................... 2
P. C. BOARD LAYOUTS ................................................................ 9
REFRIGERANT SYSTEM DIAGRAM ...................................... 1 0
DISASSEMBLY ILLUSTRATION ............................................... 1 2
PARTS LIST .................................................................................. 2 4
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
FREQUENCY (Hz) 50
COMPRESSOR
DIMENSIONS
WEIGHT
REFRIGERANT CHARGING
PIPE LENGTH 5 m(16 ft) 10 m(33 ft) 15 m(49 ft) 20 m(66 ft) 25 m(82 ft) 30 m(99 ft)
FULL CHARGE ARY30ALA 2,650g(93.5 oz.) 2,735g(96.5 oz.) 2,820g(99.5 oz.) 2,905g(102.5 oz.) 2,990g(105.5 oz.) 3,075g(108.5 oz.)
AMOUNT
ARY30RLA 2,850g(100.5 oz.) 3,100g(109.3 oz.) 3,350g(118.2 oz.) 3,600g(127.0 oz.) 3,850g(135.8 oz.)
Note : Between 5 m and 30 m, when using a connection pipe other then that in the table, charge additional refrigerant with 17 g(0.6 oz.)/1 m(3.3 ft)
for ARY30ALA, 50 g(1.76 oz.)/1 m(3.3 ft) for ARY30ALA as the criteria.
The above list shows values at the external static pressure of 12mm Aq. (118 Pa.)
1
CIRCUIT DIAGRAM
Models : ARY36ALA3, ARY36ALB3/AOY36ACA3L
ARY45ALA3, ARY45ALB3/AOY45ACA3L
INDOOR
UNIT
WHITE
1
RED
(RELAY)
BLUE 1
MAIN RELAY
2
PCB
RED RED
2
3
BLACK CN.16
4
CN.201
TO OUTDOOR UNIT
THERMISTOR
(PIPE TEMP) RE BL
CN.10 AC
GRAY D K
1
GRAY BLACK 3
OUTDOOR
2 1
UNIT
2
THERMISTOR 2
(PIPE TEMP) BLACK 1
CN.9 3
BLACK
1 CN.1 BLACK
BLACK 3
CONTROL
2 BLACK
REMOTE
1 2
WHITE
WHITE RED
CN.7
TRANSFORMER
BLUE BLU
PURPLE 1 1 E
1 PURPLE PUR
PURPLE 2 2 PLE
2 WHITE WHITE
3 3 FAN
FAN MOTOR CN.6 BLACK BLACK MOTOR
CAPACITOR 4 4
WHITE PINK PINK
1 5 5 D
WHITE RED RE
2 6 6
CN.4 CN.5
GREEN
TEST
1 2 3
CN.12
OUTDOOR
UNIT BLACK
INTERNAL C BLUE
COMPRESSOR
CONNECTOR
OVERLOAD
PROTECTOR
RED
S R THERMAL
BELT
THERMOSTAT
6 1 H L PROTECTOR
HEATER
MAIN RELAY
FAN MOTOR
OUTDOOR
WHITE
COMPRESSOR
RED
BROWN
CAPA CI TOR
CONNECTOR
C
WHITE
5 4 BLACK
BLUE
BROWN
TERMINAL WHITE
WHITE
YELLOW PURPLE
FAN MOTOR
7 2 4 1 3 RED CAPACITOR
BLACK
FUSE
RELAY
WHITE
5A
BROWN
BLACK
8 6 5 BLACK
BLACK
RED
WHITE
GREEN/YELLOW
2
L N 3 (N) 1
TERMINAL
2
Models : ARY36RLA3, ARY36RLB3/AOY36RCB3L
ARY45RLA3, ARY45RLB3/AOY45RCB3L
INDOOR
UNIT
WHITE
1
RED
(RELAY)
BLUE 1
MAIN RELAY
2
PCB
RED RED
2
3
BLACK CN.16
4
CN.201
TO OUTDOOR UNIT
THERMISTOR
(PIPE TEMP) RE BL
CN.10 AC
GRAY D K
1
GRAY BLACK 3
OUTDOOR
2 1
UNIT
2
THERMISTOR 2
(PIPE TEMP) BLACK 1
CN.9 3
BLACK
1 CN.1 BLACK
BLACK 3
CONTROL
2 BLACK
REMOTE
1 2
WHITE
WHITE RED
CN.7
TRANSFORMER
BLUE BLU
PURPLE 1 1 E
1 PURPLE PUR
PURPLE 2 2 PLE
2 WHITE WHITE
3 3 FAN
FAN MOTOR CN.6 BLACK BLACK MOTOR
CAPACITOR 4 4
WHITE PINK PINK
1 5 5 D
WHITE RED RE
2 6 6
CN.4 CN.5
GREEN
TEST
1 2 3
CN.12
OUTDOOR
UNIT
12 34
12 34
CN10
TEST
CN7
GRAY
CN11
THERMAL
1 2
FAN MOTOR
PROTECTOR GRAY
C COMPRESSOR BLACK
THERMISTOR
12 34
WHITE
CN5
BLUE BLACK
CN12
OVERLOAD
1 2
PROTECTOR BLACK
CONNECTOR
THERMISTOR
S R (OUTDOOR TEMP.)
CN6
1 2
BROWN
CN13
WHITE
1 2
BROWN
RED
FAN MOTOR
CAPACITOR THERMISTOR
WHITE (DISCHARGE TEMP.)
CN4
1 2
WHITE PURPLE
CN2
1 2
TRANSFORMER
COMPRESSOR PURPLE
CAPACITOR
WHITE
1 5
POWER
CN15
RED
RELAY
1 2
RED RED
CN3
1 2
RED
4 6
SOLENOID
BLACK
BLACK BLACK
COIL
12 34
SV
CN9
1 2
WHITE
CN1
WHITE BLACK
GREEN/YELLOW
BLUE RED
HEATER
GREEN BLACK
CN8
BELT
1 2
2
TERMINAL L R 3 (N) 1 BLACK
CONNECTOR
3
R1 R2 R3 R4
SW14 SW5
38
SW12 SW11
39
SW8 SW6 SW7 6V
40
SW3 SW1 SW2 SW4 IC5 D14 IC4 D17
41 49 1 2 0 1
1
3 G
C1 C2 C3 C4 C10 RED
D15 R15
C12 C13 C14 C15
DS1 D9 D10 D11 D12 ZD4 ZD5 D16
1 C11
2 D18
DS2-6 R33 3
R5 R6 R7 R8 BLACK
3 BT
4 29
5 30
6
Models : ARY30ALA
32
1
2 31
3
DS2
1 ZD4 ZD5
R9
4 D13 48
C102 3 68
DS2 IC6 47
C6 58 R20
C5 C101
2 46 Q2 C16 R22 D19
C7 CL1 R17 R21
59 IC3
J5 55 8 2
FB1
1
3
4 2
C8 CL2 R14 WHITE
56 ZD8 Q1
R10 R11 R12 R13 R32 (D19)
C9
42 52
R18 Q4
43
44 R19
45
4
ZD6 ZD7
IC2
60 5 12 R23 LED5
22 69
S0
21 70 61 4 13
S1
20 71 62 3 14
S2
LCD 19 72 63 2 15 R26 LED2
S3
26 73
S4 64 1 16 R27 LED3
CIRCUIT DIAGRAM
25 74
S5
24 75 6.7
S6 57
18 76
S7
29 77 54
S8 JA C20 C103
30 78 25
REMOTE CONTROL UNIT
S9 26 C17
32 79
S10 R29
33 80 27 C18
S11
3 1 R30
S12 28 C19
4 2
S13 R31
5 3 33
S14
17 12
S23
16 13
S24
15 14
S25
14 15
S26
13 16
S27
12 17
S28
11 18
S29
2 19
S30
10 20
S31
23.31 21
COM1
9.27 22
COM2
6.8 23
COM3
7.28 24
COM4
R1 R2 R3 R4
SW14 SW5
38
SW12 SW11
39
SW8 SW6 SW7 6V
40
SW3 SW1 SW2 SW4 IC5 D14 IC4 D17
41 49 1 2 0 1
1
3 G
C1 C2 C3 C4 C10 RED
D15 R15
C12 C13 C14 C15
DS1 D9 D10 D11 D12 ZD4 ZD5 D16
1 C11
2 D18
DS2-6 R33 3
R5 R6 R7 R8 BLACK
3 BT
4 29
5 30
6
Models : ARY30RLA
32
1
2 31
3
DS2
1 R9 ZD4 ZD5
4 D13 48
C102 3 68
DS2 IC6 47
C6 58 R20
C5 C101
2 46 Q2 C16 R22 D19
C7 CL1 R17 R21
59 IC3
55 8 2
FB1
1
3
4 2
C8 CL2 R14 WHITE
56 ZD8 Q1
R10 R11 R12 R13 R32 (D19)
C9
42 52
R18 Q4
43
44 R19
45
5
ZD6 ZD7
IC2
60 5 12 R23 LED5
22 69
S0
21 70 61 4 13
S1
20 71 62 3 14
S2
LCD 19 72 63 2 15 R26 LED2
S3
26 73
S4 64 1 16 R27 LED3
25 74
S5
24 75 6.7
S6 57
18 76
S7
29 77 54
S8 JA C20 C103
30 78 25
S9 26 C17
32 79
S10 R29
33 80 27 C18
S11
3 1 R30
S12 28 C19
4 2
S13 R31
5 3 33
S14
17 12
S23
16 13
S24
15 14
S25
14 15
S26
13 16
S27
12 17
S28
11 18
S29
2 19
S30
10 20
S31
23.31 21
COM1
9.27 22
COM2
6.8 23
COM3
7.28 24
COM4
INDOOR PRINTED CIRCUIT BOARD
Models : ARY30ALA CIRCUIT DIAGRAM
6
Models : ARY30RLA
7
OUTDOOR PRINTED CIRCUIT BOARD
Models : ARY30RBJL CIRCUIT DIAGRAM
8
PRINTED CIRCUIT BOARD LAYOUTS
INDOOR UNIT (Viewed from the solder side)
OUTDOOR UNIT
(Viewed from the solder side)
9
RELAY PCB ASSEMBLY
10
REFRIGERANT SYSTEM DIAGRAM
Models : ARY30ALA/AOY30ABJL
Refrigerant pipe
9.53mm(3/8")
Capillary
Distributor tube
Dryer
Pressure check
Charging valve valve
Compressor
Evaporator
Condenser
Accumulator
Muffler
Refrigerant pipe
15.88mm(5/8")
Charging valve
Models : ARY30RLA/AOY30RBJL
Refrigerant pipe
Capillary
9.53mm(3/8") tube
Check valve
Compressor
Evaporator
Condenser
Accumulator
Muffler
Pressure check
Refrigerant pipe valve
15.88mm(5/8")
Charging valve
Cooling Check Valve
Heating
: Flare coupling
11
DISASSEMBLY ILLUSTRATION
Models : AOY30ABJL
12
13
14
15
Models : AOY30RBJL
16
17
18
19
Models : ARY30ALA, ARY30RLA
20
21
Models : ARY30ALA
22
Models : ARY30RLA
23
ARY30ALA /AOY30ABJL
ARY30RLA /AOY30RBJL
PARTS LIST
OUTDOOR UNIT
24
ARY30ALA /AOY30ABJL
ARY30RLA /AOY30RBJL
[ INDOOR UNIT P. C. B. ] When you oeder parts, please make a photocopy of this page
CONTROLLER PCB ASSEMBLY (Ref. No. 236) and fill the number of the parts in the "Order" column.
Order Order
Ref. No. Description Part No. Ref. No. Description Part No.
Q" ty Q" ty
[ OUTDOOR UNIT P. C. B. ]
CONTROLLER PCB ASSEMBLY (Ref. No. 236)
Order Order
Ref. No. Description Part No. Ref. No. Description Part No.
Q" ty Q" ty
[ INDOOR UNIT P. C. B. ]
CONTROLLER PCB ASSEMBLY (Ref. No. 236)
Order
Ref. No. Description Part No.
Q" ty
25
INDOOR UNIT ACCESSORIES
Name and Shape Q'ty Application ARY30ALA ARY30RLA
Installation
1 For positioning the indoor unit 9357036007 9357036007
template
Special nut B
4 313005446759 313005446759
(small filange)
Coupler heat
insulation 2 For indoor side pipe joint 9350716029 9350716029
(large) (large pipe)
Coupler heat
insulation 1 For indoor side pipe joint 9352766015 9352766015
(small) (small pipe)
Nylon fastener
1 For fixing the drain hose 312300787605 312300787605
Remote
1 9701673032 9701673032
control unit
Remote
control unit 10 For instaling the remote 313714181904 313714181904
cord clamp control unit cord
Hexagon wrench
For opening the refrigerant
1 9351228019 9351228019
valve on the outdoor unit.
Cable clip
For power cord binding.
2 313739340109 313739340109
26