Professional Documents
Culture Documents
Ericsson SP 420: Key Features (DC and AC Options) and Field Replaceable Fan Tray
Ericsson SP 420: Key Features (DC and AC Options) and Field Replaceable Fan Tray
› Sync capabilities
– Synchronous Ethernet
– External Sync ports with 1PPS
– Phase/time synchronization with 1588v2
* In later release
TECHNICAL SPECIFICATIONS
Ericsson sp 420
CONFIGURATIONS • PW Redundancy (RFC 6718)
• Physical Dimension: Height 1.5 RU, Depth 255mm, • LSP configuration with LDP (RFC 5036) or static
Width 446mm • LDP/IGP Synchronization (RFC 5443)
• 2 slots for expansion modules • RSVP and RSVP-TE (RFC 2205, RFC 3209)
• Air flow: Right to Left • H-MPLS (RFC 3107)
• Forwarding capacity: 120 Gbps (bi-directional) • L3VPN Option C (RFC 4364)
• Weight: 8 kg
• USB port for file uploads and downloads LAYER 2 ENCAPSULATION AND RESILIENCY
• One RJ-45 console port • IEEE 802.1Q Virtual LAN (single tag)
• One 10/100/1000 Base-T Ethernet for Out-of-Band • IEEE 802.1ad Provider Bridging (single and double tag)
Management • LAG (802.1ax)
• Fan Tray with DB-15 alarm input/output connector
• Two Sync ports for 1pps + TOD ETHERNET SERVICES
• 20FE/GE SFP ports • E-LINE (EP LINE, EVP LINE)
• 8 out of the 20 GE ports are combination SFP or
RJ45 10/100/1000BaseT ports NETWORK MANAGEMENT
• SNMP v1/v2c/v3
OPTIONAL EXPANSION MODULE • Syslog
• 8 T1/E1 ports (on RJ45 ports) Circuit Emulation • RMON
module
• RADIUS
• 1 port 10GE module*
• TACACS+
• Supported by IP Transport NMS
OPERATING ENVIRONMENT
• Supported by ServiceON EM
• Operating Temperature: -40°C to 65°C
• Access via CLI
• Humidity: 0 – 95% Non-condensing
• Power: -48 VDC; 110 – 240 VAC
QUALITY OF SERVICE
• NEBS Level III
• Single-rate three color marker (RFC 2697)
• UL 60 950-1, GR-63 Core, GR-1089 Core
• Policing from 64kbps to 1Gbps
• ETSI EN 300 386, FCC Part 15
• Class of service from IEEE802.1p, DSCP, MPLS TC
• RoHS-6
• Access Control Lists (ACL)
• 8 queues (tail-drop, WRED)
POWER CONSUMPTION
• Scheduling combinations of Strict Priority and/or
• Typical 58 Watts DRR
• Egress Port Shaping
IPV4 ROUTING PROTOCOLS
• OSPF (RFC 2328, RFC 3137, RFC 3101) OAM
• IS-IS (RFC 1142, 1195) • IP BFD (RFC 5880, RFC 5881)
• BGP (RFC 4271, RFC 4760, RFC 4724) • LSP Ping and Traceroute (RFC 4379)
• LDP (RFC 3036, RFC 3478) • TWAMP Reflector (RFC 5357)
• LDP/IGP Synchronization (RFC 5443)
• IP Multicast (RFC 2236, RFC 3376, RFC 4601, RFC PERFORMANCE
4607)
• Line rate forwarding from 64 byte to 9600 bytes
• RIPv2 (RFC 2453) on all ports (L2 and L3 forwarding)
• VRF/Multiple routing contexts
TIMING AND SYNCHRONIZATION
MPLS RELATED PROTOCOLS • IEEE 1588-2008 for phase/time synchronization
• L3VPN (RFC 4364) • ITU-T G.8261/G.8262/G.8264 Synchronous Ethernet
• L2VPN/VPWS (RFC 4448, RFC 4664, RFC 3916, • 1PPS output
RFC 3623)
* In later release
Ericsson AB
SE-417 56 Göteborg, Sweden EN/LZT 110 5210
Telephone +46 10 719 00 00 © Ericsson AB 2014
www.ericsson.com All technical data is typical and is subject to change without notice