Direct Drive
Type RH..C, ER..C, GR..C
Copyright
ZIEHL-ABEGG AG reserves in its entirety the copyright of this catalogue.
This catalogue is meant for your own use only and must not be forwarded to third
parties without our written consent. The contents of the catalogue - including
parts thereof - may not be published.
General information
The information and data contained in this catalogue were established to our
best ability and do not dispense the user from his duty to check the suitability of
the products with respect to its intended application.
The sale of the products is subject to the “Technical Conditions of Sale” for fans
to Precision Class 1 in accordance with German standard DIN 24 166.
The customer is obligated to inform the supplier about general information con-
cerning the intended use, the type of installation, the operating conditions and
any other conditions that need to be taken into consideration if the order is not
based on catalogue information.
All plenum fans Type ER..C / GR..C with assembled NEMA motor can only be
ordered from Ziehl-Abegg Inc.
Certified Ratings
Ziehl-Abegg Inc. certifies that the type ER35C-ER11C and GR35-GR63C Plenum
Fans shown herein are licensed to bear the AMCA seal. The ratings shown are
based on tests and procedures performed in accordance with AMCA publication
211 and AMCA publication 311 and comply with the requirements of the AMCA
Certified Ratings Program.
The RH..C product line is not licensed to bear the AMCA seal.
Explanation of technical details ER35C
1 GR35C
1
12.0
BHP
hp
11.0
2 7.5
54% 5.0
3765
10.0 rpm
3600 92
9.0 5
3
ηs
71%
3.0
8.0 3300 90
4 LW A
i
dB
7.0 88
3060
psF [in.wg]
6.0 2900 86
2.0
84
7 5.0 1.5
2590
82
2400 80
4.0
1.0
2100 76
3.0 0.75
1900 47%
1800 72
2.0
1.0
ER35C
0.0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
ηs qV [CFM] 6
Explanation of the diagrams psF [in.wg] ηs
1 Fan size
q [CFM] ∆ psF [in.wg] ⋅
2 PL: Shaft power in hp. It is: BHP = V
6362 ηs ⋅
3 ηfaL
ŋ s : efficiency of the impeller based on the static
qpressure
V [CFM]
p [in.wg]
4 90: A-weighted sound power level at the inletsFin dB
5 n: fan speed in rpm
6 q : airflow in CFM qV [CFM]
V
7 psF: static pressure in in.wg
Air performance tested in accordance with AMCA 210. Ratings developed in accordance with AMCA 311, 301 and AMCA 211.
Inlet sound testing performed in accordance with ISO 13347 - Part 3.
High tech by Ziehl-Abegg
Plenum Fan
Ziehl-Abegg, well-known for top quality and high performance air moving systems
in the worldwide marketplace, is a leading supplier of plenum fans. Plenum Fans
are designed and engineered for superior performance, highest efficiency and
lowest sound power levels. The heart of the Ziehl-Abegg Plenum fan system is
the patented rotating diffusor which reduces noise and helps increase overall
system efficiency at levels not achieved before in the AHU industry.
Application Versatility
Impeller RH..C with hub
Plenum fans offer a practical design option for any industrial and commercial
air-handler or pressurized plenum room application. They are designed for un-
housed operation which results in space saving and allows for ductwork to be
directly connected to the plenum walls of the air-handling unit. This offers maxi-
mum application flexibility. System air is supplied or returned to the air-handling
unit from virtually any direction with a minimum of ductwork. Plenum fans are
excellent solutions for retrofit projects where limited space is a common problem
as well as in variable air volume systems.
Design Features
Direct Drive
Direct drive units (arrangement 4) are usually operated with a VFD to achieve a
range of duty points within the performance capability of the motor. The choice
of motors was made to allow operation directly at the mains when bypassing the
VFD in case a failure occurs. The selected motors can operate up to the listed
maximum frequencies. Motors are sized correctly to provide required torque at
Design GR..C for vertical airflow
higher speed.
• Inlet cone with measuring device for airflow measurement based on the
principle of a flow nozzle. According to Ziehl-Abegg laboratory tests this
system was determined to be accurate within +/-5%.
• Complete assembly vibration testing to ensure smooth operation.
Maximum peak velocity is 2.8 mm/s (0.11 in/s).
Impeller
• Design optimized for operation without scroll by special blades with rotating
diffusor for high efficiency and good acoustic performance
• With hub in half key balancing according to DIN ISO 8821, quality of balan-
cing G 2,5 / G 6,3 according to ISO 1940, part 1, resp. ANSI/AMCA 204
• After installation, the impeller must be put through a function test. A „balance
test“ is necessary in the installed condition – rebalance if applicable.
The start-up time for the impellers please see in the table to the right.
Direction of rotation
Clockwise rotation when looking at the inlet of the impeller. In the opposite di-
rection, i.e. impellers with forward curved blades, there is the danger that the
motor will overload. It is therefore absolutely necessary to check the direction
of rotation before putting the fan into operation.
Direction of rotation
Type Moment of inertia max. speed Weight impeller with Weight inlet ring
taperlock-hub taperlock-hub
[Ib.ft2] rpm Ibs Ibs
RH22C 0.0427 5940 6.4 1.3
RH25C 0.616 5350 7.3 1.5
RH28C 0.996 4775 9.7 1.8
RH31C 1.732 4245 12.4 2.43
RH35C 2.681 3765 14.8 2.9
RH40C 5.007* / 4.865** 3340 20.1* / 16.5** 4.6
RH45C 8.306 2970 28.0 5.5
RH50C 15.828 2675 39.0 6.8
RH56C 25.201 2310 49.0 8.4
RH63C 51.186 2060 79.2 10.4
RH71C 81.394 1840 97.0 12.8
RH80C 166.015 1620 148.8 20.1
RH90C 270.878 1475 201.5 24.9
RH10C 522.985 1280 294.1 30.9
RH11C 1197.98 1280 528.7 37.5
Inlet ring
• Made of galvanised sheet steel
• With measuring device for airflow measurement
• Fastening pitch diameter in conformity with DIN EN 12 220
Dimensions
Type DA DE DE1 D1 D5 E1 H H1 T W1° ZxW1° W2° ZxW2° Guard
Inlet ring
(1) (1) (2) (2) (3)
Article no
a b
RH22C 00401503 00401736 9.96 5.31 5.31 7.05 0.33 9.17 0.47 1.65 0.06 60° 6x60° - - 00279175
RH25C 00401504 00401737 10.91 6.02 6.02 7.95 0.33 10.12 0.47 1.85 0.06 60° 6x60° - - 00279178
RH28C 00401505 00401738 11.93 6.73 6.73 8.86 0.33 11.14 0.47 2.05 0.06 60° 6x60° - - 00279179
RH31C 00401506 00401739 13.50 7.60 7.60 9.96 0.33 12.48 0.47 2.32 0.06 90° 4x90° 120° 3x120° 00279180
RH35C 00401296 00401740 14.88 8.58 8.78 11.26 0.33 13.86 0.47 2.60 0.06 90° 4x90° 120° 3x120° 00279181
RH40C 00401297 00401741 16.46 9.69 9.92 12.68 0.33 15.43 0.51 2.91 0.08 90° 4x90° 120° 3x120° 00279182
RH45C 00401298 00401742 18.27 10.94 11.22 14.33 0.33 17.24 0.55 3.27 0.08 90° 4x90° 120° 3x120° 00279183
RH50C 00401299 00401743 20.24 12.28 12.60 16.14 0.33 19.21 0.63 3.70 0.08 90° 4x90° 120° 3x120° 00279726
RH56C 00401300 00401744 22.20 13.66 13.98 17.91 0.33 21.18 0.71 4.09 0.08 90° 4x90° 120° 3x120° 00279727
RH63C 00401301 00401745 24.96 15.31 15.63 20.08 0.41 23.62 0.79 4.61 0.08 60° 6x60° 90° 4x90° 00405196
RH71C 00401302 00401746 27.72 17.20 17.60 22.60 0.41 26.38 0.91 5.16 0.08 60° 6x60° 90° 4x90° 00405197
RH80C 00401303 00401747 30.87 19.41 19.84 25.43 0.41 29.53 0.98 5.83 0.10 60° 6x60° 90° 4x90° 00405198
RH90C 00401304 00401748 34.41 21.85 22.32 28.66 0.41 33.07 1.14 6.57 0.10 45° 8x45° - - 00405199
RH10C 00401305 00401749 38.35 24.61 25.08 32.24 0.41 37.01 1.26 7.36 0.10 45° 8x45° - - 00405200
RH11C 00401306 00401750 42.32 27.32 27.83 35.83 0.41 40.98 1.42 8.19 0.10 45° 8x45° - - 00409771
a) with measuring device, made of galvanised sheet steel
b) with measuring device, plastic coated
(1) mounting inlet ring
(2) mounting inlet guard
(3) inlet guard grill for RH..C
Dimensions
Type Article no D B B2 DA DD DE DN DSA D1 D5 E1 H H1 H2 U Z
RH22C/SM12-1 on request 5/8 - 1 1/8 0.98 2.44 9.96 10.12 5.31 10.12 9.02 7.05 0.33 9.17 5.79 1.65 3.62 0.08 3x120°
RH25C/SM12-1 on request 5/8 - 1 1/8 0.98 2.76 10.91 11.42 6.02 11.42 10.16 7.95 0.33 10.12 6.42 1.85 4.06 0.10 3x120°
RH28C/SM12-2 on request 5/8 - 1 1/8 0.98 3.07 11.93 12.68 6.73 12.68 11.26 8.86 0.33 11.14 7.05 2.05 4.53 0.12 3x120°
RH31C/SM12-2 on request 5/8 - 1 1/8 0.98 3.43 13.50 14.17 7.60 14.17 12.60 9.96 0.33 12.48 7.83 2.32 5.04 0.12 4x90°
RH35C/SM12-2 on request 5/8 - 1 1/8 0.98 3.86 14.88 15.98 8.58 15.98 14.17 11.26 0.33 13.86 8.74 2.60 5.67 0.14 4x90°
RH40C/SM12-2 on request 5/8 - 1 1/8 0.98 4.33 16.46 17.99 9.69 17.99 15.98 12.68 0.33 15.43 9.76 2.91 6.42 0.16 4x90°
RH40C/SM20 on request 7/8 - 1 5/8 1.26 4.33 16.46 17.99 9.69 17.99 15.98 12.68 0.33 15.43 9.84 2.91 6.42 0.16 4x90°
RH45C/SM20 on request 7/8 - 1 5/8 1.26 4.88 18.27 20.28 10.94 20.28 18.03 14.33 0.33 17.24 10.98 3.27 7.20 0.18 4x90°
RH50C/SM20 on request 7/8 - 1 5/8 1.26 5.51 20.24 22.80 12.28 22.80 20.28 16.14 0.33 19.21 12.28 3.70 8.11 0.20 4x90°
RH56C/SM20 on request 7/8 - 1 5/8 1.26 6.10 22.20 25.35 13.66 25.35 22.52 17.91 0.33 21.18 13.54 4.09 9.02 0.24 4x90°
RH63C/SM25 on request 1 3/8 - 2 1/8 1.77 6.85 24.96 28.39 15.31 28.39 25.24 20.08 0.41 23.62 15.43 4.61 10.08 0.26 6x60°
RH71C/SM25 on request 1 3/8 - 2 1/8 1.77 7.72 27.72 31.93 17.20 31.93 28.39 22.56 0.41 26.38 17.20 5.16 11.34 0.28 6x60°
RH80C/SM25 on request 1 3/8 - 2 1/8 1.77 8.70 30.87 35.98 19.41 35.98 32.01 25.43 0.41 29.53 19.29 5.83 12.80 0.31 6x60°
RH90C/SM30 on request 1 7/8 - 2 3/8 2.01 9.80 34.41 40.55 21.85 40.55 36.06 28.66 0.41 33.07 21.73 6.57 14.41 0.35 8x45°
RH10C/SM30 on request 1 7/8 - 2 3/8 2.01 11.02 38.35 45.63 24.61 45.63 40.55 32.24 0.41 37.01 24.29 7.36 16.22 0.39 8x45°
RH11C/SM30 on request 2 3/8 - 2 7/8 2.01 15.35 42.32 50.67 27.32 50.87 45.07 35.83 0.41 40.98 30.12 8.19 21.26 0.43 8x45°
RH11C/SM35 on request 3 3/8 3.54 15.35 42.32 50.67 27.32 50.87 45.07 35.83 0.41 40.98 30.27 8.19 21.26 0.43 8x45°
• Integrated inlet ring designed for optimum air flow, made of galvanised
steel sheet with measuring device for determination of airflow
(see page 18)
• NEMA premium efficiency motor 230 /460 V, 60 Hz, three phase; Foot With standard NEMA motor
mounted
• NEMA premium motor in 575 V 60Hz and 200 / 208 V 60Hz on request
Spring damper
Spring vibration dampers can be employed to prevent the transfer of structure-
borne sound and oscillations to plants and buildings. When correctly arranged,
they possess a high degree of isolation efficiency and correspondingly high
deflection. Please refer to the technical data for placement and dimensions.
Scope of delivery: Spring dampers are not mounted.
Rubber damper
As an alternative to spring vibration dampers, rubber dampers can be used
for structure-borne sound isolation. These possess a lower level of isolation
efficiency but have good attenuation properties, which can be advantageous in
certain kinds of set-ups. In the case of high fan speeds and rigid substructures
or a concrete foundation, installing rubber dampers is often sufficient. Please
refer to the technical specifications for placement and dimensions.
Scope of delivery: Rubber dampers are not mounted.
15.75
Scope of delivery: Flexible inlet collars are mounted at the front plate.
The fans are not ready-for-use products, but have been conceived as components
°
120
for air conditioning, ventilation, and exhaust air removal systems for machine
3x
GR28 - GR63
• Bolted supporting structure made of galvanized sheet steel or of sheet steel
with an epoxy-/ polyester powder coating RAL 7032
• Ventilation data (fan curve) and motor BHP allocation equivalent to ER..C
Dimensions
Fan size A G H H1 H H1 H3 L L1
Ibs. Vu Vu Vo Vo
max.* max.* max.*
GR28C 73 14.57 M6 8.54 20.16 8.27 19.88 0.39 15.94 13.58
GR31C 97 16.14 M6 9.53 21.97 9.06 21.50 0.59 17.72 14.76
GR35C 99 17.72 M6 10.63 22.87 10.12 22.36 0.59 19.69 16.34
GR40C 161 19.69 M6 11.57 26.69 11.10 26.22 0.59 21.65 18.11
GR45C 185 21.65 M6 12.91 28.03 12.44 27.56 0.59 23.62 20.31
GR50C 289 24.21 M8 14.76 34.13 13.90 33.27 0.98 26.38 22.83
GR56C 320 27.17 M8 15.94 35.31 15.16 34.53 0.98 29.53 25.39
GR63C 425 30.71 M8 17.91 36.89 17.13 36.10 0.98 33.07 28.43
Mounting Position H
4.33
* Measuring device
GR unit in H
Free-running fans from the C-series can be quickly and easily selected using our
ZAselect-ZRVUS fan selection program.
During selection of the RH..C models without a motor or ER..C with a standard motor, it is possible
to input the dimensions of the air handling unit.
The characteristic curve of the fan and the acoustic power as compared with the characteristic-curve
information are influenced by installation of the fan in an air handling unit. Likewise, the use of a
guard grille has an influence on the characteristic curve and the acoustics. This influence on the
behavior of centrifugal fans was investigated by Ziehl-Abegg in experiments. These influences can
be calculated in the ZAselect-ZRVUS selection program. The diagram is merely meant to display a
qualitative tendency of the empirically ascertained correction factors.
1
Adjustment
reference surface
In box sections with unequal side lengths, a reference surface F (equivalent parameter) consisting
of device-width A and device-high B can be calculated as an iteration when there is a minimum clea-
rance of 0,3 * DSa between the impeller and the device wall. F= √A*B
The differential pressure compares the static pressure in front of the inlet ring
with the static pressure in the inlet ring of the narrowest point.
The technique is based on the Bernoulli and Continuity equations, which allow
calculation of airflow through a converging nozzle based upon measurement of
the static pressure drop across the nozzle.
Nozzle coefficients
type k-factor
RH22C 437
RH25C 558
RH28C 697
RH31C 883
RH35C 1124
RH40C 1431
RH45C 1830
RH50C 2413
RH56C 2861
RH63C 3540
RH71C 4552
RH80C 5760
RH90C 7330
RH10C 9281
RH11C 11455
Example:
If differential pressure of 2.87 in.wg is measured for size 630, the airflow rate
can be calculated:
q = k.√ ∆pw = 3540 .√ 2.87
V
= 6000 cfm
The corresponding differential pressure/airflow rate curves can be downloaded
from our website under product informations in the download area.
Type key
R H_ _C. _ _ /_ _ _ _ - _ _ _
Inlet nozzle
0 = scope of delivery without
inlet nozzle
A = galvanised sheet
B = galvanised sheet with measuring
device
C = plastic coating
D = plastic coating with measuring
device
E = galvanised sheet with ring circuit
F = plastic coating with ring circuit
X = Ex-inlet ring (copper) with
measuring device
Impeller size
22 = 225 mm
...
11 = 1120 mm
Type key
ER _ _C-_ _ _ - _ _-_ _
GR
Direction of rotation
Impeller blade external-diameters
1 = standard
Motor design
7 = NEMA foot mounted
5 = NEMA C-Face no base
Motor size
Motor
M = Asynchronous NEMA motor
Y = Explosion-protected motor
Type of current
H = Asynchronous standard motor
with built-on frequency inverter
D = three-phase current
O = without motor (kit)
Pole number
2 = 2 pole
4 = 4 pole
6 = 6 pole
8 = 8 pole
Impeller size
22 = 225 mm
...
11 = 1120 mm
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 11.02 0.43 12.99 6.79 12.40 11.34 18.11 14.31 13.94 1.81 11.97 1.81 5.57 0.47
2 11.02 0.43 12.99 6.79 12.40 11.34 18.11 14.31 13.94 1.81 11.97 1.81 5.57 0.47
3 11.02 0.43 12.99 6.79 12.40 11.34 18.11 15.56 14.02 2.52 13.31 2.05 5.57 0.47
4 11.02 0.43 12.99 6.79 12.40 11.34 18.11 16.06 14.41 2.52 13.54 2.20 5.57 0.47
9.0
BHP
1.5 hp
8.0 54%
5175 2.0
5100
rpm
88
7.0
1.0 LW A
i
dB
ηs
71%
6.0 86
4500
0.75 84
5.0
4070
psF [in.wg]
82
0.5
80
4.0
3550
78
3.0 3200
74
0.25
2800
2.0 70 47%
2550
2320
66
62
1.0
1725 ER22C
0.0
0 200 400 600 800 1000 1200 1400 1600 1800
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 14.17 0.43 16.34 8.46 15.75 11.34 18.11 14.96 13.94 1.81 12.44 1.73 6.22 0.47
2 14.17 0.43 16.34 8.46 15.75 11.34 18.11 16.21 13.78 2.68 14.33 1.65 6.22 0.47
3 14.17 0.43 16.34 8.46 15.75 11.34 18.11 16.71 14.25 2.68 14.88 1.65 6.22 0.47
4 14.17 0.43 16.34 8.46 15.75 11.34 22.44 19.22 18.90 1.57 17.56 1.65 6.22 0.47
11.0
BHP
hp
54%
10.0 5175
rpm 2.0 3.0 90
9.0
ηs
71%
8.0 1.5
4600
88
7.0 LW A
i
dB
4200 86
1.0
6.0
psF [in.wg]
84
5.0 3700
0.75 82
3340 80
4.0
0.5 78
3.0 2855
2550 74 47%
0.25
2.0 2320 70
66
1725
1.0 ER25C
0.0
0 500 1000 1500 2000 2500
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 14.17 0.43 16.34 8.46 15.75 11.81 18.11 16.84 13.70 3.03 14.88 1.65 6.85 0.47
2 14.17 0.43 16.34 8.46 15.75 11.81 18.11 16.84 13.70 3.03 14.88 1.65 6.85 0.47
3 14.17 0.43 16.34 8.46 15.75 11.81 18.11 17.34 13.23 3.50 14.65 2.09 6.85 0.47
4 14.17 0.43 16.34 8.46 15.75 11.81 18.11 17.84 12.68 4.06 14.02 2.72 6.85 0.47
5 14.17 0.43 16.34 8.46 15.75 11.81 22.44 19.85 18.98 1.89 18.27 1.65 6.85 0.47
11.0
54% BHP
4775
hp
10.0 rpm
3.0
5.0
90
9.0 4450 LW A
i
dB
ηs
71%
2.0 88
8.0
7.0 86
3850
1.5
6.0 84
psF [in.wg]
3520
82
5.0
1.0
3100 80
4.0 78
2855 0.75
0.5
3.0 2550
74
47%
2320
70
2.0 0.25
66
1725
1.0 ER28C
0.0
0 500 1000 1500 2000 2500 3000 3500
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 14.17 0.43 16.34 8.46 15.75 11.81 18.11 16.38 14.09 2.44 13.86 1.69 7.64 0.47
2 14.17 0.43 16.34 8.46 15.75 11.81 18.11 17.63 13.23 3.70 14.72 2.20 7.64 0.47
3 14.17 0.43 16.34 8.46 15.75 11.81 18.11 18.63 12.36 4.57 13.70 3.23 7.64 0.47
4 14.17 0.43 16.34 8.46 15.75 11.81 18.11 18.63 12.36 4.57 13.70 3.23 7.64 0.47
5 14.17 0.43 16.34 8.46 15.75 11.81 18.11 18.63 12.13 4.80 13.46 3.46 7.64 0.47
6 14.17 0.43 16.34 8.46 15.75 11.81 22.44 20.64 18.90 2.44 19.13 1.69 7.64 0.47
11.0
54% BHP
4245 hp
10.0 rpm
5.0
4100
3.0
9.0
88 ηs
71%
8.0
3665
86
2.0
7.0 LW A
i
dB
6.0 3250 84
psF [in.wg]
1.5
82
5.0 2930
80
1.0
4.0
2550 78
76
0.75
3.0 2320
47%
0.5 72
2.0
68
1725
1.0 ER31C
0.0
0 500 1000 1500 2000 2500 3000 3500 4000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 18.11 0.43 20.47 10.63 19.69 15.16 22.44 18.52 17.48 1.81 16.22 1.69 8.52 0.47
2 18.11 0.43 20.47 10.63 19.69 15.16 22.44 19.02 18.19 1.81 17.09 1.69 8.52 0.47
3 18.11 0.43 20.47 10.63 19.69 15.16 22.44 19.52 18.43 1.81 17.32 1.69 8.52 0.47
4 18.11 0.43 20.47 10.63 19.69 15.16 22.44 21.53 17.64 3.23 19.53 1.69 8.52 0.47
5 18.11 0.43 20.47 10.63 19.69 15.16 22.44 21.90 17.56 3.70 18.66 2.60 8.52 0.47
14.37
3
12.0
BHP
hp
11.0
54% 5.0 7.5
3765
10.0 rpm
3600
92
9.0
ηs
71%
3.0
8.0 3300 90
LW A
i
dB
7.0 88
psF [in.wg]
6.0 2900 86
2.0
84
5.0 1.5
2590
82
2400 80
4.0
1.0
2100 76
3.0 0.75
1900 47%
1800 72
2.0
1.0 ER35C
0.0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 18.11 0.43 20.47 10.63 19.69 15.16 22.44 20.74 17.48 1.81 16.38 1.69 9.55 0.47
2 18.11 0.43 20.47 10.63 19.69 15.16 22.44 20.54 18.58 1.81 17.48 1.69 9.55 0.47
3 18.11 0.43 20.47 10.63 19.69 15.16 22.44 20.04 18.66 1.81 17.56 1.69 9.55 0.47
4 18.11 0.43 20.47 10.63 19.69 15.16 22.44 20.54 18.90 1.81 17.40 1.89 9.55 0.47
5 18.11 0.43 20.47 10.63 19.69 15.16 22.44 22.55 16.69 4.17 17.80 3.07 9.55 0.47
6 18.11 0.43 20.47 10.63 19.69 15.16 22.44 22.92 16.93 4.33 17.95 3.31 9.55 0.47
14.37
3
7.0
54%
2625
5.0
6.0 rpm
BHP
hp 86
2475 3.0
ηs
2.0 71%
5.0 84
1.5 82
2150 LW A
i
4.0 dB
80
psF [in.wg]
1950
1.0 78
3.0
0.75 76
1700
1560
72
2.0 0.5
47%
68
1140
1.0
ER40C
0.0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 22.05 0.43 25.59 13.19 24.80 18.31 22.44 22.14 18.11 1.73 17.01 1.69 10.67 0.47
2 22.05 0.43 25.59 13.19 24.80 18.31 22.44 21.94 19.13 1.73 18.03 1.69 10.67 0.47
3 22.05 0.43 25.59 13.19 24.80 18.31 28.35 24.32 22.36 1.73 21.34 1.69 10.67 0.47
4 22.05 0.43 25.59 13.19 24.80 18.31 28.35 24.32 22.60 1.73 21.57 1.69 10.67 0.47
5 22.05 0.43 25.59 13.19 24.80 18.31 28.35 23.95 22.05 1.81 21.18 1.69 10.67 0.47
6 22.05 0.43 25.59 13.19 24.80 18.31 28.35 24.32 22.60 1.81 21.81 1.69 10.67 0.47
7 22.05 0.43 25.59 13.19 24.80 18.31 28.35 25.69 24.33 2.83 25.67 1.69 10.67 0.47
9.0
BHP
53%
2625 hp
8.0
rpm
5.0 7.5
92
ηs
7.0 72%
2400
90
3.0 LW A
i
6.0 dB
88
5.0
86
psF [in.wg]
2025
2.0
84
4.0 1.5
1740 82
1615
3.0
1.0 78
0.75 48%
1400
2.0 74
1140 70
1.0
ER45C
0.0
0 1000 2000 3000 4000 5000 6000 7000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 22.05 0.43 25.59 13.19 24.80 18.31 28.66 25.95 23.62 1.97 22.36 2.05 12.30 0.79
2 22.05 0.43 25.59 13.19 24.80 18.31 28.66 25.95 23.86 1.97 22.68 2.05 12.30 0.79
3 22.05 0.43 25.59 13.19 24.80 18.31 28.66 26.64 23.07 4.49 24.88 3.07 12.30 0.79
4 22.05 0.43 25.59 13.19 24.80 18.31 28.66 25.95 23.94 2.05 23.07 1.93 12.30 0.79
5 22.05 0.43 25.59 13.19 24.80 18.31 28.66 27.32 24.02 3.94 25.04 2.91 12.30 0.79
6 22.05 0.43 25.59 13.19 24.80 18.31 28.66 26.64 22.83 5.12 23.78 4.17 12.30 0.79
7 22.05 0.43 25.59 13.19 24.80 18.31 34.96 30.20 29.76 3.70 30.55 2.91 12.30 0.79
12.0
BHP 15.0
hp
11.0
10.0
53%
2640
10.0 rpm
7.5 96
2500 ηs
9.0 72%
94
8.0 LW A
i
dB
2265
92
7.0 5.0
90
psF [in.wg]
6.0
1975
88
5.0 3.0
86
1660
4.0
2.0
82
1.5
1450
3.0 48%
1325
78
2.0 1160
1.0 ER50C
0.0
0 2000 4000 6000 8000 10000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 28.35 0.43 32.01 17.05 29.92 25.98 28.35 27.21 24.57 1.69 23.31 1.69 13.56 0.79
2 28.35 0.43 32.01 17.05 29.92 25.98 28.35 27.90 22.91 4.65 24.09 3.46 13.56 0.79
3 28.35 0.43 32.01 17.05 29.92 25.98 28.35 27.90 22.36 5.20 23.46 4.09 13.56 0.79
4 28.35 0.43 32.01 17.05 29.92 25.98 28.35 28.58 23.07 4.49 24.25 3.31 13.56 0.79
5 28.35 0.43 32.01 17.05 29.92 25.98 28.35 27.90 21.73 5.83 22.83 4.72 13.56 0.79
6 28.35 0.43 32.01 17.05 29.92 25.98 34.65 31.46 28.98 4.49 29.92 3.54 13.56 0.79
11.0
BHP
hp
10.0 53%
2310
15.0
rpm 10.0 96
9.0
ηs
7.5 72%
2100
8.0 94
LW A
i
dB
7.0
1910 92
5.0
6.0 90
psF [in.wg]
5.0 1650 88
3.0 86
4.0
1400
2.0 82
3.0 48%
1215
1160 78
2.0
1.0 E560C
0.0
0 2000 4000 6000 8000 10000 12000 14000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 28.35 0.43 32.01 17.05 29.92 25.98 34.65 29.46 30.87 1.69 29.45 1.69 15.12 0.79
2 28.35 0.43 32.01 17.05 29.92 25.98 34.65 32.27 28.90 4.76 30.16 3.50 15.12 0.79
3 28.35 0.43 32.01 17.05 29.92 25.98 34.65 35.70 25.91 7.76 27.01 6.65 15.12 0.79
4 28.35 0.43 32.01 17.05 29.92 25.98 34.65 33.02 28.11 5.55 29.37 4.29 15.12 0.79
5 28.35 0.43 32.01 17.05 29.92 25.98 34.65 34.20 26.61 7.05 27.80 5.87 15.12 0.79
11.0
BHP 20.0
hp
10.0 53%
2060 15.0
rpm
1980 96
9.0
ηs
10.0
72%
8.0
94
7.5
7.0
1725
92
LW A
i
6.0 dB
psF [in.wg]
90
5.0
1525
5.0
88
1375
86
4.0
3.0 84
1160
3.0
48%
80
2.0
1.0 ER63C
0.0
0 2500 5000 7500 10000 12500 15000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 35.83 0.43 40.28 21.38 37.80 29.53 41.14 34.28 33.86 2.36 32.60 2.36 17.13 0.98
2 35.83 0.43 40.28 21.38 37.80 29.53 41.14 34.28 35.20 2.36 34.02 2.36 17.13 0.98
3 35.83 0.43 40.28 21.38 37.80 29.53 41.14 37.71 36.69 3.07 37.01 2.36 17.13 0.98
4 35.83 0.43 40.28 21.38 37.80 29.53 41.14 39.83 33.70 6.06 34.65 5.12 17.13 0.98
5 35.83 0.43 40.28 21.38 37.80 29.53 41.14 36.21 37.40 2.36 36.30 2.36 17.13 0.98
6 35.83 0.43 40.28 21.38 37.80 29.53 41.14 37.33 34.80 4.96 35.83 3.94 17.13 0.98
11.0
BHP
53% hp
10.0 1840
rpm 20.0 25.0
1800
9.0
15.0 ηs
72%
96
8.0
1630
94
10.0
7.0
LW A
i
dB
7.5
6.0 1425 92
psF [in.wg]
90
5.0 1295
5.0 88
86
4.0
1125
84
3.0
3.0 48%
80
2.0 850
1.0 ER71C
0.0
0 5000 10000 15000 20000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 T T1 T3 T4 T5 T6 T7 T8
1 35.83 0.43 40.28 21.38 37.80 29.53 41.14 36.32 34.57 2.36 33.39 2.36 19.17 0.98
2 35.83 0.43 40.28 21.38 37.80 29.53 41.14 38.26 36.46 3.31 35.98 2.99 19.17 0.98
3 35.83 0.43 40.28 21.38 37.80 29.53 41.14 43.70 31.50 8.27 32.44 7.32 19.17 0.98
4 35.83 0.43 40.28 21.38 37.80 29.53 41.14 41.88 32.76 7.01 33.78 5.98 19.17 0.98
5 35.83 0.43 40.28 21.38 37.80 29.53 41.14 42.38 30.79 8.98 31.65 8.11 19.17 0.98
6 35.83 0.43 40.28 21.38 37.80 29.53 41.14 42.51 29.61 10.16 30.47 9.29 19.17 0.98
7 35.83 0.43 40.28 21.38 37.80 29.53 41.14 43.01 29.76 10.00 30.63 9.13 19.17 0.98
11.0
BHP
25.0 hp
10.0 53% 20.0
1620 30.0
rpm
1580
9.0
15.0 ηs
72%
8.0 1470 96
LW A
i
dB
7.0
94
1340
6.0 10.0 92
psF [in.wg]
7.5
1170 90
5.0
88
1060
4.0
5.0 86
925 84
3.0 48%
850
80
2.0
1.0 ER80C
0.0
0 5000 10000 15000 20000 25000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 L3 T T1 T3 T4 T5 T6 T7 T8
1 44.09 0.43 49.76 26.54 46.46 37.40 15.75 45.67 46.20 39.69 4.80 40.94 3.54 21.67 1.18
2 44.09 0.43 49.76 26.54 46.46 37.40 15.75 45.67 46.20 41.18 3.31 41.73 2.36 21.67 1.18
3 44.09 0.43 49.76 26.54 46.46 37.40 15.75 45.67 44.88 38.90 5.59 40.16 4.33 21.67 1.18
4 44.09 0.43 49.76 26.54 46.46 37.40 15.75 45.67 45.01 37.87 6.61 39.13 5.35 21.67 1.18
5 44.09 0.43 49.76 26.54 46.46 37.40 15.75 45.67 45.51 38.03 6.46 39.29 5.20 21.67 1.18
6 44.09 0.43 49.76 26.54 46.46 37.40 15.75 51.97 45.75 45.35 5.24 46.46 4.13 21.67 1.18
11.0
BHP
53%
30.0 hp
10.0 1465
rpm
25.0 40.0
9.0 1375 ηs 98
72%
20.0
8.0 1300 96
LW A
i
dB
7.0 15.0
1200 94
6.0
psF [in.wg]
92
1090
10.0
5.0 90
950 88
4.0
870 86
48%
84
3.0
2.0
1.0 ER90C
0.0
0 5000 10000 15000 20000 25000 30000 35000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D H H1 L L2 L3 T T1 T3 T4 T5 T6 T7 T8
1 44.09 0.43 50.39 27.17 46.46 37.40 15.75 45.67 48.78 38.82 5.67 40.24 4.25 24.25 1.18
2 44.09 0.43 50.39 27.17 46.46 37.40 15.75 51.97 50.68 45.12 5.47 46.30 4.29 24.25 1.18
3 44.09 0.43 50.39 27.17 46.46 37.40 15.75 51.97 50.68 44.65 5.95 45.83 4.76 24.25 1.18
4 44.09 0.43 50.39 27.17 46.46 37.40 15.75 51.97 52.61 41.18 9.41 42.28 8.31 24.25 1.18
5 44.09 0.43 50.39 27.17 46.46 37.40 15.75 51.97 48.33 42.99 7.60 44.17 6.42 24.25 1.18
6 44.09 0.43 50.39 27.17 46.46 37.40 15.75 51.97 49.71 42.36 8.23 43.54 7.05 24.25 1.18
11.0
BHP
40.0 hp
10.0 53%
1280 50.0
rpm
30.0
1250
9.0
25.0
ηs
72% 98
8.0
1130
20.0 96
7.0 LW A
i
1060 dB
94
15.0
6.0
psF [in.wg]
985 92
5.0 90
900
870
88
4.0
3.0 48%
2.0
1.0 ER10C
0.0
0 5000 10000 15000 20000 25000 30000 35000 40000
qV [CFM]
(T5)+(T6) are valid for mounting with flexible inlet collar from Ziehl-Abegg and Baldor
standard NEMA motor according to Ziehl-Abegg design
A D L L2 L3 T T1 T3 T4 T5 T6 T7 T8 T11
1 53.15 0.43 55.12 47.24 15.75 64.17 58.67 57.09 2.76 57.09 2.76 29.92 1.18 -
2 53.15 0.43 55.12 47.24 15.75 64.17 58.67 57.09 2.76 57.09 2.76 29.92 1.18 -
3 53.15 0.43 55.12 47.24 15.75 64.17 62.78 59.84 2.76 59.84 2.76 29.92 1.18 -
4 53.15 0.43 55.12 47.24 15.75 64.17 62.78 59.84 2.76 59.84 2.76 29.92 1.18 -
5 53.15 0.43 55.12 47.24 15.75 64.17 58.67 59.84 2.76 59.84 2.76 29.92 1.18 -
6* 53.15 0.43 55.12 47.24 15.75 70.67 62.77 57.48 10.87 57.48 10.87 29.92 1.18 28.74 * set of 6 pieces required
13.0
BHP
50% 75.0
hp
12.0 1280 100.0
rpm
11.0
ηs
60.0 69%
1185
10.0 10
0
LW A
i
50.0 dB
9.0
1100
98
8.0 40.0
1030
96
7.0
psF [in.wg]
30.0
960
94
6.0 25.0
870 92
20.0
5.0 820
90
760 88
4.0 47%
3.0
2.0
1.0 ER11C
0.0
0 10000 20000 30000 40000 50000 60000 70000
qV [CFM]
Subsidiaries, Distributors
Subsidiaries, Distributors
Czech Republic Germany Iraq Lithuania
Ziehl-Abegg s.r.o. Ziehl-Abegg AG supported by supported by
Škrobárenská 484/8 Heinz-Ziehl-Straße Ziehl-Abegg Vantilator ve Motor Ziehl-Abegg Polska Sp. z o.o.
617 00 BRNO 74653 KÜNZELSAU San ve Tic. Ltd. Sti. POLAND
CZECH REPUBLIC GERMANY TURKEY
Phone +420 5 45421690 Phone +49 7940 16-0 Macedonia
Fax +420 5 45421699 Fax +49 7940 16-300 Ireland
www.ziehl-abegg.cz www.ziehl-abegg.com supported by
sales@ziehl-abegg.cz info@ziehl-abegg.de supported by Ziehl-Abegg Ges.m.b.H.
Ziehl-Abegg UK Ltd. AUSTRIA
Denmark GREAT BRITAIN
Great Britain
Malaysia
Ziehl-Abegg Danmark ApS Ziehl-Abegg UK Ltd. Italy supported by
Agerhatten 27, B 1th Springfield Business Park
Ziehl-Abegg Italia S.r.l. Ziehl-Abegg SEA Pte. Ltd.
5220 ODENSE SØ Lonebarn Link, Unit 1
Via Primo Maggio 10 SINGAPORE
DENMARK CHELMSFORD, ESSEX CM2 5AR
Phone +45 66 155800 GREAT BRITAIN 30031 DOLO (VE)
Fax +45 66 155810 Phone +44 1245 4490-10 ITALY Mexico
www.ziehl-abegg.com Fax +44 1245 4490-11 Phone +39 041 5130-311
supported by
carsten.sundman@ziehl-abegg. www.ziehl-abegg.co.uk Fax +39 041 5131-953
Ziehl-Abegg Inc.
com info@ziehl-abegg.co.uk www.ziehl-abegg.it
USA
info@ziehl-abegg.it
Ecuador Greece Moldova
Japan
supported by Helcoma supported by
Ziehl-Abegg do Brasil Imp., 65 Davaki Str. Ziehl-Abegg Japan Co., Ltd. OOO Ziehl-Abegg
Exp. e Com. de Equipamentos 17672 KALLITHEA, ATTIKI 20F Yokohama Landmark Tower RUSSIA
de Ventilação Ltda. GREECE 2-2-1 Minatomirai Nishi-ku
BRASIL Phone +30 21 0 9513705 YOKOHAMA CITY KANAGAWA
Fax +30 210 9513490 220-8120 Montenegro
Estonia www.helcoma.gr JAPAN
contact@helcoma.gr Phone +81 45 6707027 supported by
supported by Fax +81 45 6707177 Ziehl-Abegg Ges.m.b.H.
Ziehl-Abegg Finland OY info@ziehl-abegg.jp AUSTRIA
Hungary
FINLAND
supported by
Jordan Netherlands
Finland Ziehl-Abegg Ges.m.b.H.
Ziehl-Abegg Benelux B.V.
AUSTRIA supported by
Ziehl-Abegg Finland OY Ambacht 6
Phone +36 30 821 5226 Ziehl-Abegg Vantilator ve Motor
Olarinluoma 11 5301 KW ZALTBOMMEL
San ve Tic. Ltd. Sti.
02200 ESPOO Iceland NETHERLANDS
TURKEY
FINLAND Phone +31 418 572430
Phone +358 10 40068-00 Varmi HF Fax +31 418 572439
Laugavegi 168 Kazakhstan
Fax +358 10 40068-10 www.ziehl-abegg.nl
www.ziehl-abegg.fi 0105 REYKJAVIK supported by info@ziehl-abegg.nl
info@ziehl-abegg.fi ICELAND OOO Ziehl-Abegg
Phone +354 5517560 RUSSIA New Zealand
Fax +354 5624110
France www.varmi.is supported by
Korea Ziehl-Abegg Australia Pty Ltd (VIC)
Ziehl-Abegg FMV S.A.R.L. varmi@varmi.is
Rue de la gare Jung Air Technics Co., Ltd. AUSTRALIA
01800 VILLIEU India #831, Hyundai Etrebeau Bldg.
FRANCE 852, Janghang-Dong, Ilsan-Ku Norway
Ziehl-Abegg India Pvt Ltd. GOYANG-CITY (411-837)
Phone +33 474 4606-20
# 219, 2nd Floor, supported by
Fax +33 474 611958 KOREA
Akshay Complex, Ziehl-Abegg Sverige AB
www.ziehl-abegg.fr Phone +82 31 9033071
Dhole Patil Road SWEDEN
societe@ziehl-abegg.fr Fax +82 31 9033072
PUNE - 411 001 www.jungairtechnics.com
Georgia
INDIA jat@nuri.net Paraguay
Phone +91 20 6640 0975
Fax +91 20 6640 0994 supported by
supported by Kyrgyzstan
www.ziehl-abegg.in Ziehl-Abegg do Brasil Imp.,
Ziehl-Abegg Vantilator ve Motor
vikas.kundra@ziehl-abegg.com supported by Exp. e Com. de Equipamentos
San ve Tic. Ltd. Sti.
OOO Ziehl-Abegg de Ventilação Ltda.
TURKEY
RUSSIA BRASIL
Indonesia
supported by Latvia
Ziehl-Abegg SEA Pte. Ltd.
SINGAPORE supported by
Ziehl-Abegg Polska Sp. z o.o.
POLAND
Grill guard
0.35 0.59 ER..C Art.no. D E1
ER22-25C 00409757 7.99 9.17
°
120
0.35 0.59
°
90
4x
ER..C Art.no. D E1
ER63C 00409766 21.89 23.62
ER71C 00409767 24.33 26.38
ER80C 00409768 27.17 29.53
ER90C 00409769 30.31 33.07
ER10C 00409770 33.86 37.01
øD ER11C 00409771 37.80 40.98
øE1
Spring damper
Subsidiaries, Distributors
Peru Slovenia Tajikistan
supported by supported by supported by
Ziehl-Abegg do Brasil Imp., Ziehl-Abegg Ges.m.b.H. OOO Ziehl-Abegg
Exp. e Com. de Equipamentos AUSTRIA RUSSIA
de Ventilação Ltda.
BRASIL South Africa Thailand
Ziehl-Abegg South Africa (Pty) Ltd. supported by
Philippines
51 Loper Road Ziehl-Abegg SEA Pte. Ltd.
supported by Spartan / Aeroport SINGAPORE
Ziehl-Abegg SEA Pte. Ltd. Kempton Park
SINGAPORE JOHANNESBURG Turkey
SOUTH AFRICA
Poland Phone +27 11 9744211 Ziehl-Abegg Vantilator ve Motor
Fax +27 11 9747970 San ve Tic. Ltd. Sti.
Ziehl-Abegg Polska Sp. z o.o. www.ziehl-abegg.co.za Atatürk Mah. Firat Bulvari
ul. Sochaczewska 13 info@ziehl-abegg.co.za Gardenya Plaza 3. Binasi
01-327 WARSZAWA Kat:3 Ofis No: 17
POLAND 34758 ATAŞEHIR-İSTANBUL
Spain
Phone +48 22 6654933 TURKEY
Fax +48 22 6640134 Ziehl-Abegg Ibérica S.L. Phone +90 216 5808250
www.ziehl-abegg.pl C/ Calidad 58 Fax +90 216 5809530
biuro@ziehl-abegg.pl Polígono Industrial Los Olivos www.ziehl-abegg.com.tr
28906 GETAFE (MADRID) omur.aydogan@ziehl-abegg.com.tr
Portugal SPAIN
Phone +34 91 2953008
supported by Turkmenistan
Fax +34 91 2953014
Ziehl-Abegg Ibérica S.L. www.ziehl-abegg.es supported by
SPAIN info@ziehl-abegg.es Ziehl-Abegg Vantilator ve Motor
San ve Tic. Ltd. Sti.
Romania Sweden TURKEY
supported by Ziehl-Abegg Sverige AB
Ziehl-Abegg Ges.m.b.H. Ukraine
Kvartsgatan 11
AUSTRIA 749 40 ENKÖPING Ziehl-Abegg Ukraine Ltd
SWEDEN 46 Budenogo str.
Russia Phone +46 171 8588-0 08700 OBUHOV, KIEV REGION
Fax +46 171 8588-1 UKRAINE
OOO Ziehl-Abegg
www.z-abegg.se Phone +38 067 4637958
73, Sovetskaya Str.
info@z-abegg.se Fax +38 044 4927409
Korolev
ua.ziehl-abegg.com
141070 MOSCOW REGION
Switzerland info@ziehl-abegg.com.ua
RUSSIA
Phone +7 495 2322355 Ziehl-Abegg Schweiz AG
Fax +7 495 2322353 Uruguay
Limmatstrasse 12
www.ziehl-abegg.ru 8957 SPREITENBACH supported by
info@ziehl-abegg.ru SWITZERLAND Ziehl-Abegg do Brasil Imp.,
Phone +41 56 41850-10 Exp. e Com. de Equipamentos
Serbia Fax +41 56 41850-15 de Ventilação Ltda.
supported by www.ziehl-abegg.ch BRASIL
Ziehl-Abegg Ges.m.b.H. info@ziehl-abegg.ch
AUSTRIA Uzbekistan
Syria
supported by
Singapore supported by OOO Ziehl-Abegg
Ziehl-Abegg SEA Pte. Ltd. Ziehl-Abegg Vantilator ve Motor RUSSIA
57 Ubi Avenue 1 San ve Tic. Ltd. Sti.
#05-04, Ubi Centre TURKEY Venezuela
SINGAPORE 408936 supported by
SINGAPORE Taiwan
Ziehl-Abegg do Brasil Imp.,
Phone +65 67482587 Tuntos Enterprise Co., Ltd. Exp. e Com. de Equipamentos
Fax +65 67487357 No. 23-1, Alley 10, Lane 437, de Ventilação Ltda.
www.ziehl-abegg.sg Pa-Der Road, Sec 2, BRASIL
info@ziehl-abegg.com.sg Taipei 105, Taiwan R.O.C.
Phone +886 2 27512135 Vietnam
Slovakia Fax +886 2 27775343
www.tuntos.com.tw supported by
supported by Ziehl-Abegg SEA Pte. Ltd.
tuntos@ms23.hinet.net
Ziehl-Abegg s.r.o SINGAPORE
CZECH REPUBLIC
Ziehl-Abegg Inc.
6348 Burnt Poplar Rd., Greensboro, NC 27409
Tel. +1 (336) 834-9339, Fax +1 (336) 834-9340
info@ziehl-abegg.us, www.ziehl-abegg.us