Revisions to F-CON V Pro Ver. 3.

3 PowerWriter

Revisions to Ver. 3.30D


- Problem after change of Pressure Unit was solved.
- Problem after closing Parameter 1 was solved.
- Monitor auto-off function and system stand-by function after elapsed time will
not be activated.
- Voltage Airflow Input can be selected in Voltage Output 3 and 4.
- Data Monitor can be shown with the use of IF Unit.
- Problem of the graph editing function of Voltage Output Map was solved.
- Problem of display appearing by a left click under log-linking to Compare Log was
solved.

-----------------------------------------------------------------------------------
----------------------------------------

Revisions to Ver. 3.30C


- Problem of output of log data to text data was solved.
- Printing Parameter 2 was adjusted.

-----------------------------------------------------------------------------------
----------------------------------------

Revision to Ver. 3.30B


- Problem of showing Internal Log was solved. After the change, it is no longer
compatible with Ver.3.24 log data.
- In Compare Parameter, problem of showing Option Voltage Output was solved. A map
addition display was added.
- Hint for the input range for Fuel/Oil Pressures of Parameter 2 to Option Switch 2
was revised.

-----------------------------------------------------------------------------------
----------------------------------------

Revision to Ver. 3.30A


- Problem after change of Pressure Unit of the X axis for Fuel/Ignition
Corrections�f Fuel Pressure Correction Map was solved.

-----------------------------------------------------------------------------------
----------------------------------------

Revisions to Ver. 3.30 (Ver. 3.301)


- Change of Data Monitor. "*****" will be shown when Oil Pressure, Oil Temp. or
Fuel Pressure are OFF.
- Change of log. When Option Voltage Output is set for VALCON and logged, it always
shows the VALCON value starting from the next log.
- Input range of Ignition Cut R.P.M. Hold was changed.
- SR20DE was added to Base Engines.
- "HKS_MT1" in Oil Temperature Conversion Table was changed to "HKS_MOT1".
- "HKS" in Water Temperature Conversion Table was changed to "HKS_MWT1".
-----------------------------------------------------------------------------------
----------------------------------------

Revisions to Ver. 3.30 (Ver. 3.30)


- File extension of data file was changed from *.FR5 to *.FZ3 since F-CON V Pro
Version 3.3. Log file was changed from *.LR5 to *.LZ3.
- 4B11 and M16A were added to Base Engine.
- MITSUBISHI2, SUZUKI1, NISSAN5 were added to Crank Signal Type.
- Oil Temperature Conversion Table was added. Fuel Pressure Conversion Table was
deleted.
- Fuel Pressure Conversion Parameter and Oil Pressure Conversion Parameter were
added.
- VALCON value is shown in Option Voltage Output Map.
- Names of tabs in Parameter were changed.
Basic1 was changed to Basic
Control was changed to Input
Basic3 was changed to Pressure Conversion
Basic2 was changed to Sub
Error was added
- Deceleration Fuel Cut was added to Car Speed Conditions. Fuel Cut Delay Time and
Decay Coefficient are in the Deceleration Fuel Cut group.
- Ignition Cut of Option Switch Input was changed to Ignition Cut (Start). Ignition
Cut (Speed) and Ignition Cut (Hold) were added. Ignition Cut R.P.M. of Ignition2
in the group (Ignition Cut R.P.M. (Switch) was changed to Start. "Car Speed
Condition - ON" was changed to Hold. Speed Input was added).
- Time Over Speed Pulse Number, Compensation, and Volume R.P.M. are in the group of
Ignition Cut (Start) Setting.
- Number of current errors, accumulated number of errors, and error codes are shown
in Parameter.
- Map Addition function was added to Option Voltage Output.
- VALCON Control function was added to Option Voltage Output. During VALCON
Control, Map and monitor display can be changed to VALCON angle display. For
VALCON Control, settings for maximum / minimum Voltage Output values were changed
to the most advanced / retarded angles.
- Fuel Pressure, Oil Pressure, and Oil Temperature conditions were added to Option
Switch Output 3 and 4.
- R.P.M. condition was added to Option Switch output 6 - 9.
- Option Communication setting was added.
- R.P.M. was added to Option Frequency Output.
- Air Flow Input Voltage, Voltage Output Value, and Current Gear Position can be
shown on Data Monitor.
- Oil Temperature, Fuel Pressure, and Oil Pressure were added to Conversion Table.
- �hHKS�h was added to Water Temperature Conversion Table.
- �hHKS_MT1�h was added to Oil Temperature Conversion Table.
- User Name, ID, and Data Creator are shown in VERSION INFORMATION of HELP.
- ID Registration screen appears when PowerWriter is started for the first time.