AAAAAAAcoction

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 22

SM6 DM1-A TITT2 SM6 DM1-A TITT1 SM6 DM1-A TLP SM6 DM1-A CE SM6 NSM SM6 GAM2

1 SM6 DM1-A TLP SM6 DM1-A CE SM6 NSM SM6 GAM2 SM6 QM SM6 IM
(ZP0SM6DM1CSF1TITT2) (ZP0SM6DM1CSF1TITT1) (ZP0SM6DM1CSF1CTLP) (ZP0SM6DM1CE) (ZP0SM6NSMT200S) (ZP0SM6GAM2) (ZP0SM6QM) (ZP0SM6IM)
SM6 DM1-D SM6 GBM

24kV, 20kA, 630A 24kV, 16kA, 630A 24kV, 20kA, 630A 24kV, 16kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A
24kV, 20kA, 630A

630A 630A 630A 630A 630A 630A


630A

-RP -RP

50/51, 50/51, -RP


50N/51N, 50N/51N,
630A 46
630A 46, 49 630A 630A 630A
50/51,
-P1 -P1 50N/51N,
46
kW, kW-h, kW, kW-h,
V, I, V, I,
cos(phi) cos(phi)

300-150/5A, 200-100/5A, 5-630A/ 200/1A, Cl


Cl 0.2, 5VA Cl 0.5, 5VA 22.5mV, Cl 0.5-5P
0.5-5P
300-150/5A, 200-100/5A,
5P20, 5VA 5P15, 5VA

22.9:V3/0.23:V3 kV, 22.9:V3/0.23:V3 kV, 22.9:V3/0.23:V3 kV,


CL 0.2, 10VA CL 0.2, 10VA CL 0.2, 10VA
22.9:V3/0.23:V3 kV, 22.9:V3/0.23:V3 kV, 22.9:V3/0.23:V3 kV,
3P, 10VA 3P, 10VA 3P, 10VA

LV LV LV LV LV
BOX BOX BOX BOX BOX
H =450mm H =450mm H =450mm H =450mm H =450mm
W =750mm W =750mm W =750mm W =750mm W =750mm
| | | | |

David Antonio Tapia Oré


Product Application Engineer
Power Systems, Medium Voltage
Schneider Electric
Perú - Bolivia
Cel: +51.940.237.035
SM6 - DM1A SM6 - DM1A SM6 - DM1A SM6 - DM1A SM6 - DM1A SM6 - GAM-2 SM6 - QM SM6 - IM
24kV 24kV NSM Cables 750
24kV 24kV 24kV 24kV 24kV 24kV
H =2050 mm
H =1600 mm H =1600 mm H =1600 mm H =1600 mm H =1600 mm H =1600 mm H =1600 mm H =1600 mm
W =750 mm W =750 mm W =750 mm
W =750 mm W =750 mm W =750 mm W =375 mm W =375 mm W =375 mm
D =1220 mm D =1220 mm D =940 mm
D =1220 mm D =1220 mm D =1220 mm D =940 mm D =940 mm D =940 mm
W =260 kg
W =400 kg W =400 kg W =400 kg W =400 kg W =400 kg W =120 kg W =130 kg W =120 kg
neer
Voltage
TAPAS LATERALES DE CELDAS SM6 STOCK

AL ARMAR UNA SUBESTACION DE 04 CELDAS POR EJEMPLO, EN LAS CELDAS INTERMEDIAS SE DEBE RETIRAR
SU TAPA RESPECTIVA Y SE DEBE REUBICAR UNA DE ESAS TAPAS EN EL EXTREMO QUE FALTA LA TAPA. CON
ELLO ESTÁN SOBRANDO DOS TAPAS LATERALES Y ESTA SUBESTACIÓN TENDRÍA 04 PALANCAS DE MANDO.

LV LV
BOX
BOX
H =450mm
H =450mm
W =750mm
W =750mm
| |

SM6 - DM1A SM6 - DM1A SM6 - QM 24kV SM6 - QM 24kV SM6 - QM 24kV
24kV 24kV
H =1600 mm H =1600 mm H =1600 mm
H =1600 mm H =1600 mm
W =375 mm W =375 mm W =375 mm
W =750 mm W =750 mm D =940 mm D =940 mm D =940 mm
D =1220 mm D =1220 mm
W =130 kg W =130 kg W =130 kg
W =400 kg W =400 kg

David Antonio Tapia Oré


Product Application Engineer
Power Systems, Medium Voltage
Schneider Electric
Perú - Bolivia
Cel: +51.940.237.035
1.5MVA
10/2.3kV
1250mm
SM6 DM1-A TLP SM6 DM1-A TLP
(ZP0SM6DM1CSF1CTLP) (ZP0SM6DM1CSF1CTLP)

24kV, 20kA, 630A 24kV, 20kA, 630A

630A 630A

-RP
630A 630A
50/51,
50N/51N,
46

5-630A/ 5-630A/
22.5mV, Cl 22.5mV, Cl
0.5-5P 0.5-5P

LV LV
BOX BOX
H =450mm H =450mm
W =750mm W =750mm
| |
2625 mm
SM6 - DM1A SM6 - DM1A
24kV 24kV
H =1600 mm H =1600 mm
W =750 mm W =750 mm
D =1220 mm D =1220 mm
W =400 kg W =400 kg

QTY
ZP0SM6DM1CSF1CTLP 3
ZP0SM6QM 1
CHPAFIN 1
51006520M0 1
KIT-EXTENSOR 1
59635 1
ZP0EM… 1
SE 690 - A

M6 DM1-A TLP SM6 QM SM6 DM1-A TLP


M6DM1CSF1CTLP) (ZP0SM6QM) (ZP0SM6DM1CSF1CTLP)

24kV, 20kA, 630A 24kV, 20kA, 630A

630A
630A

-RP -RP
630A
50/51, 50/51,
50N/51N, 50N/51N,
46 46

5-630A/
22.5mV, Cl
0.5-5P

LV
BOX
H =450mm
W =750mm
|
SM6 - QM SM6 - DM1A
24kV 24kV
H =1600 mm
H =1600 mm
W =750 mm
W =375 mm
D =1220 mm
D =940 mm
W =400 kg
W =130 kg
CLIENTE INDUSTRIAS
SALDARRIAGA

SM6 GAM2 SM6 DM1-A TITT2 SM6 GAM2 SM6 QM SM6 IM SM6 DM1-A TLP
(ZP0SM6GAM2) (ZP0SM6DM1CSF1TITT2) (ZP0SM6GAM2) (ZP0SM6QM) (ZP0SM6IM) (ZP0SM6DM1CSF1CTLP)

22.9kV, [24kV], 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A 24kV, 20kA, 630A

630A 630A 630A


630A

-RP
50A
50/51, -RP
50N/51N,
630A 46 630A
50/51,
-P1 50N/51N,
46
kW, kW-h,
V, I,
cos(phi)

300-150/5A, 5-630A/
Cl 0.2, 5VA 22.5mV, Cl
0.5-5P
300-150/5A,
5P20, 5VA

22.9:V3/0.23:V3 kV,
CL 0.2, 10VA
22.9:V3/0.23:V3 kV,
3P, 10VA

630KVA 2.5 MVA

22.9/0.4kV 22.9/0.4kV

LV
BOX LV
H =450mm BOX
W =750mm H =450mm
| W =750mm
|

David Antonio Tapia Oré


Product Application Engineer
Power Systems, Medium Voltage
Schneider Electric
Perú - Bolivia
1125mm 1875mm Cel: +51.940.237.035
SM6 - GAM-2 SM6 - DM1A SM6 - GAM-2
SM6 - QM SM6 - IM SM6 - DM1A
24kV 24kV 24kV 24kV 24kV
H =1600 mm
24kV
H =1600 mm H =1600 mm H =1600 mm H =1600 mm
W =750 mm H =1600 mm
W =375 mm W =375 mm W =375 mm W =750 mm
D =1220 mm W =375 mm
D =940 mm D =940 mm D =940 mm D =1220 mm
W =400 kg D =940 mm
W =120 kg W =130 kg W =120 kg W =400 kg
W =120 kg
SM6 DM1-A TLP
(ZP0SM6DM1CSF1CTLP)

-RP

50/51,
50N/51N,
46
DISEÑO DE SUB ESTACIÓN ELÉCTRICA PRINCIPAL

LISTADO DE EQUIPOS Y ACCESORIOS

ITEM CÓDIGO DESCRIPCIÓN CANT


Equipamiento Principal
1 ZP0SM6GAM2 UNIDAD DE ACOMETIDA DE CABLES 2
2 ZP0SM6DM1CSF1TITT2 CELDA INTERRUPTOR +TI+TT+S20+PM5560 1
3 ZP0SM6DM1CSF1CTLP CELDA INTERRUPTOR +TLP+S20 3
4 ZP0SM6QM-M UNIDAD DE SECCIONADOR FUSIBLE 1
5 ZP0SM6IM UNIDAD DE ENTRADA/SALIDA 1
Accesorios
6 ZP0EMS58580PK CARGADOR BATERIAS, Vout1=24Vcc-90W/Vin=220Vac 2
7 CHAPAFIN12.5FL-M ACCESORIOS CIERRE Y PALANCA 1
8 59635 TOROIDE P/I RESIDUAL D=120: CSH 120 1
9 51006520M0 Fusibles FUSAR CF 12kV,In: 80A, I1:63kA 3
DISEÑO DE SUB ESTACIÓN ELÉCTRICA PRINCIPAL EXANDAL S.A. - 1000msnm

SM6 GAM2 SM6 QM


(ZP0SM6GAM2) (ZP0SM6QM)

10kV (24kV), 20kA, 630A

630A

100A

PMI
Acometida 10kV 1000KVA
10/2.3kV
DISEÑO DE SUB ESTACIÓN ELÉCTRICA PRINCIPAL

DISPOSICIÓN DE EQUIPOS

1 375
2 375
750

750 mm

SM6 - GAM-2 SM6 - QM


24kV 24kV
H =1600 mm H =1600 mm
W =375 mm W =375 mm
D =940 mm D =940 mm
W =120 kg W =130 kg

DISEÑO DE SUB ESTACIÓN ELÉCTRICA PRINCIPAL

LISTADO DE EQUIPOS Y ACCESORIOS


ITEM CÓDIGO DESCRIPCIÓN
Equipamiento Principal
1 ZP0SM6GAM2 UNIDAD DE ACOMETIDA DE CABLES
2 ZP0SM6QM-M UNIDAD DE SECCIONADOR FUSIBLE
3 TRANSFORMADOR SECO 10kV/230VAC - 1000KVA
Accesorios
4 CHAPAFIN12.5FL-M ACCESORIOS CIERRE Y PALANCA
5 51006521M0 Fusibles FUSAR CF 12kV,In: 80A, I1:63kAFusibles FUSAR CF 12kV,In: 100A, I
EXANDAL S.A. - 1000msnm

SM6 QM
ZP0SM6QM)
50 mm

SM6 - QM
24kV
H =1600 mm
W =375 mm
D =940 mm
W =130 kg
CANT

1
1
C - 1000KVA 1

1
AFusibles FUSAR CF 12kV,In: 100A, I1:6 3
CELDA DE PROTECCIÓN & MEDICIÓN - TECSUP

SM6 GAM2 SM6 DM1-A TITT2


(ZP0SM6GAM2) (ZP0SM6DM1CSF1TITT2)

24kV, 20kA, 630A 24kV, 20kA, 630A

630A

-RP

50/51,
50N/51N,
630A 46

-P1

kW, kW-h,
V, I,
cos(phi)

300-150/5A,
Cl 0.2, 5VA
300-150/5A,
5P20, 5VA

22.9:V3/0.23:V3 kV,
CL 0.2, 10VA
22.9:V3/0.23:V3 kV,
3P, 10VA

DISPOSICIÓN DE EQUIPOS

LV
BOX
H =450mm
W =750mm
|

1
2

SM6 - GAM-2 SM6 - DM1A


24kV
24kV
H =1600 mm
H =1600 mm
W =750 mm
W =375 mm
D =1220 mm
D =940 mm
W =400 kg
W =120 kg

LISTADO DE EQUIPOS Y ACCESORIOS

ITEM CÓDIGO DESCRIPCIÓN CANT


Equipamiento Principal
1 ZP0SM6GAM2 UNIDAD DE ACOMETIDA DE CABLES 1
2 ZP0SM6DM1CSF1TITT2 CELDA INTERRUPTOR +TI+TT+S20+PM5560 1
Accesorios
3 CHAPAFIN12.5FL-M ACCESORIOS CIERRE Y PALANCA 1
4 ZP0EMS58580PK CARGADOR BATERIAS, Vout1=24Vcc-90W/Vin=220Vac 2
SUB ESTACIÓN ELÉCTRICA N°02

ITEM CÓDIGO

1 ZP0SM6GAM2

2 ZP0SM6QM51N

3 CHAPAFIN12.5FL-M
4 ZP0EMS58580PK
5 51006518M0

SUB ESTACIÓN ELÉCTRICA N°03

ITEM CÓDIGO

1 ZP0SM6GAM2

2 ZP0SM6QM51N

3 CHAPAFIN12.5FL-M
4 ZP0EMS58580PK
5 51006518M0
DESCRIPCIÓN CANT
Equipamiento Principal
UNIDAD DE ACOMETIDA DE CABLES 1

UNIDAD CON SECCIONADOR FUSIBLE CON PROTECCION PARA 10KV, CON PROTECCIÓN HOMOPOLAR 2

Accesorios
ACCESORIOS CIERRE Y PALANCA 1
CARGADOR BATERIAS, Vout1=24Vcc-90W/Vin=220Vac 1
Fusibles FUSAR CF 12kV,In: 50A, I1:63kA 6

DESCRIPCIÓN CANT
Equipamiento Principal
UNIDAD DE ACOMETIDA DE CABLES 1

UNIDAD CON SECCIONADOR FUSIBLE CON PROTECCION PARA 10KV, CON PROTECCIÓN HOMOPOLAR 3

Accesorios
ACCESORIOS CIERRE Y PALANCA 1
CARGADOR BATERIAS, Vout1=24Vcc-90W/Vin=220Vac 1
Fusibles FUSAR CF 12kV,In: 50A, I1:63kA 9

You might also like