ROCKSEAL C2-Dry Shake

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

C2 ROCK SEAL

Crystalline, Deep penetrative


capillary Waterproofing system
DESCRIPTION FIELDS OF APPLICATION C2
ROCKSEAL C2 contains moisture activated WATER RETAINING WATER EXCLUDING
additives that plays major role as catalyst in the • Water tanks / towers • Basements
formation of water-insoluble crystalline micro
structure deep within the capillaries & interstices of • Reservoirs • Tunnels
cementicious matrix of concrete and mortar. As the
crystalline capillary waterproofing system enables • Swimming pools • Inspection pits
effective pore sealing it does not rely on film
formation on the surface and is not affected by the
negative hydrostatic pressure. • Water treatment works • Foundations

• Dams • Retaining walls


• Permanent solution to water leakage,
ingress, or seepage in concrete structures
or any cementitious substrate. The
• Canals • Lift shafts
formation and development of insoluble •
crystals into water bearing capillaries and
• Harbors Construction joints
interstices effectively blocks the further
passage of water and ensures permanent
• Concrete pipes • Sea defense walls
water tightness for the life of the structure
• Bridge decks
• Provides total and permanent waterproofing
properties by becoming an integral part of • Jetties
the structure to which it is applied. Active
ingredients will not delaminate, peel off or • Pontoons
wear away

• Protects concrete and reinforcement


against corrosive waterborne substances

• Crystalline action is reactivated by contact


with water providing dormant additional
protection

• Effective against both positive and negative


Water pressure

• Non-toxic or non tainting

SPECIAL SURFACE WATER


ADMIXTURE SHOTCRETE GROUTS
ADMIXTURE IMPROVEMENT PROOFING
CRACK
FLOORING COATING JOINT SEALANT REPAIR TILING
INJECTION
PAGEL - CRYSTALLINE WATER PROOFING

TECHNICAL DATA PROCESSING


C2
TYPE C2
Surface preparation: quality of substrate preparation
Color Powder-grey directly affects the performance system. Surfaces to
be treated must be free from dust, oil, grease, paint
Coverage The material shall be applied at the residual curing compound, mould oil or any previous
rates and in the manner recommended surface treatment that will impair adhesion of the
ROCKSEAL® C2 treatment, or inhibit penetration of
Unmixed material 1kg / m2 the chemicals or water into the surface. These include
polymer modified renders and those substrates
Consumption 1kg / m2 per coat, minimum two coats treated with silicon or silane water repellents. Remove
any laitance and provide an open pored, slightly
PACKAGING rough surface sufficient to act as a mechanical key,
Supplied in: 25 Kg bag essential for adequate adhesion of the ROCKSEAL®
Storage: Dry; Frost free, out of direct sunlight C2 treatment. Areas of weak or honeycombed
Shelf life: 12months concrete must be repaired. Hollow, de bonding
Hazard class: No dangerous goods, Observe renders must be removed and made good. Surfaces
Material Safety datasheet. to be treated if not already wet, should be saturated
for a period of 24 hours before first applications.
DIRECTION FOR USE
New construction: APPLICATION
The vast majority of leaking water retaining (or
excluding) structures constructed of sound dense ROCKSEAL® C2 mixes are applied by brush or spray
concrete, leak only at construction or day work joints. onto the dampened substrate. Apply the material in 2
Costly remedial work can be avoided by the use of coats at right angles, the second coat whilst the first
ROCKSEAL® C2 as a dry shake onto the horizontal is firm, but 'green' - usually 3-4 hours after first coat
surfaces of joints or as a slurry application on vertical (dependant on temperature). For old concrete,
surfaces. In conditions of high water table brickwork and granular concrete blocks, replace the
ROCKSEAL® C2 may be applied as a slurry or dry second coat with a render 5-10mm thick.
shake over building concrete immediately prior to
casting the slab. This sandwich system will prevent
ingress of ground water preventing deterioration, and MIXING
dampness or flooding. Foundations should be treated
on the external face wherever possible, as should the Always add water to ROCKSEAL® C2 -not in
face of construction joints. reverse order. Mix 1 part of water to 2.25 - 2.5 parts
ROCKSEAL® C2 can be applied immediately after of powder by volume.
the formwork has been removed, as the water curing
process required will also ensure full hydration of the
concrete. If the treatment is to be exposed and an CURING
aesthetically pleasing finish is required, the
ROCKSEAL® C2 after curing should receive a ROCKSEAL® C2 must be prevented from drying out
sand/cement render on which to apply the desired too rapidly and should be kept damp for 5-7 days.
finish. Mist spraying with water and covering with polythene
is effective when drying out would otherwise take
Existing structures: place. Curing compounds are unsuitable for use with
Structures subject to water leakage or ingress must ROCKSEAL® C2 system technology. Protect from
be carefully inspected to determine the cause. Any weathering, sun, frost and wind for a similar minimum
water present should be cleared away so that a period. Tanks and other water retaining structures
thorough survey can be conducted. Static cracks may be filled 24 hours after final ROCKSEAL® C2
over 1mm must be chased out, dampened down and application as crystal growth is accelerated by water
repaired with ROCKSEAL® C2 render on a Pressure.
ROCKSEAL® C2 coat. Dynamic cracks must be
formed into watertight elastomeric movement joint.

SAFETY PRECAUTIONS
As with all chemical products, care should be taken
during use and storage to avoid contact with eyes,
mouth, skin and foodstuffs. Treat splashes to eyes
and skin immediately. If accidentally ingested, seek
immediate medical attention. Reseal containers after
use.ROCKSEAL® C2 should be handled to minimize
dust formation during mixing. Use a light mask if
excessive dust is unavoidable. For further information
refer to the material safety datasheet.

The information provided in this leaflet, is supplied by our consulting service and is the end result of exhaustive research work and extensive experience. They are, however, without
liability on our part, in particular with regard to third parties proprietary rights, and do not relieve the user of the responsibility for verifying that theproducts and processes are suitable
for the intended application. The data presented was derived from tests under normal climate conditions according to DIN 50014 and mean average values and analysis. Deviations
are possible when delivery takes place. Given that recommendations may differ from those shown in this leaflet written confirmation should be sought. It is the responsibility of the
purchaser to ensure they have the latest leaflet issue and that its contents are current. Our customer service staff will be glad to provide assistance at any time. We appreciate the
interest you have shown in our products. This technical data sheet supercedes pre viously issued information.

PAGEL PAKISTAN (PVT.) LTD.

1-A, MISC. ZONE, VALUE ADDITION CITY Phone: +92-41-850-7212-13


SAHIANWALA ROAD, KHURRIANWALA. Fax: +92-41-850-7214
FAISALABAD Email: info@pagelpakistan.com Technical Ref. Sheet 6.02 PK
Website: www.pagelpakistan.com QS-Formblatt 01/14 Rev. 02

SPECIAL SURFACE WATER


ADMIXTURE SHOTCRETE GROUTS
ADMIXTURE IMPROVEMENT PROOFING
CRACK
FLOORING COATING JOINT SEALANT REPAIR TILING