Professional Documents
Culture Documents
208.95 0 4 20 10 Input: Nominal Capacity Design For Bolt
208.95 0 4 20 10 Input: Nominal Capacity Design For Bolt
Blow UP 9
Connection Type Column to Sub-Beam Share Connection Status Failed Due To Tensile Yielding
Input
Shear Force = 208.95 kN Fy Maximum Value
Load
Axial Force = 0 kN Fx Maximum Value
Bolt Nos, n = 4
Bolt
Bolt diameter, db = 20 mm
Plate Thickness = 10 mm
Given Data
Bolt hole dia, dh = 22 mm Design for Bolt
Bolt center to edge distance, le = 40 mm Nominal Capacity = 117 kN
Bolt center to center distance, S = 80 mm Shear Capacity/Bolt = 58 kN 0.89
Ultimate Strength of plate, Fu = 0.448 kN/mm2 Total Shear Capacity of Bolt 234
= kN
Yield Strength of plate, Fy = 0.345 kN/mm2