This document provides a table of technical parameters for an HSA-992H2 chiller including:
1) Specifications for cooling capacity, inlet/outlet temperatures, flow rates, and pressure losses for chilled water, cooling water, and hot water.
2) Electrical data including power supply, total current, and electric power.
3) Overall dimensions, operating weight, and shipping weight.
4) Notes on nominal operating conditions and adjustable ranges for capacity and flow.
This document provides a table of technical parameters for an HSA-992H2 chiller including:
1) Specifications for cooling capacity, inlet/outlet temperatures, flow rates, and pressure losses for chilled water, cooling water, and hot water.
2) Electrical data including power supply, total current, and electric power.
3) Overall dimensions, operating weight, and shipping weight.
4) Notes on nominal operating conditions and adjustable ranges for capacity and flow.
This document provides a table of technical parameters for an HSA-992H2 chiller including:
1) Specifications for cooling capacity, inlet/outlet temperatures, flow rates, and pressure losses for chilled water, cooling water, and hot water.
2) Electrical data including power supply, total current, and electric power.
3) Overall dimensions, operating weight, and shipping weight.
4) Notes on nominal operating conditions and adjustable ranges for capacity and flow.
USRt 595 Cooling capacity kW 2093 10 kcal/h 4 180 Inlet/outlet temperature ℃ 14/8 Flow m /h3 300 Chilled water Pressure loss mH2O 8.5 Connection diameter (DN) mm 200 Inlet/outlet temperature ℃ 32/37 Flow m /h3 840 Cooling water Pressure loss mH2O 7 Connection diameter (DN) mm 400 Inlet/outlet temperature ℃ 88/78 Flow t/h(m /h) 3 240.2(248.5) Hot water Pressure loss mH2O 8.3 Connection diameter (DN) mm 200 Power supply 3ф-400V –50Hz Electrical data Total current A 32.8 Electric power kW 10 Length 6740 Overall Width mm 2640 dimensions Height 3770 Operating weight 37.6 t Shipping weight 26.6 Note: (1) Values for hot water, chilled water and cooling water in the above table are for nominal operation conditions, and can be properly adjusted in actual operation. (2) The lowest outlet temperature for chilled water is 5℃. (3) Cooling capacity can be adjusted in a range of 20 ~100%. Chilled water flow can be adjusted in the range of 60 ~120%. (4) On the chilled, hot and cooling water side scale factor will be 0.0001m2h℃/kcal. (5) Chilled, hot and cooling water box has the maximum pressure bearing capacity of 0.8MPa (G). (6) The chiller is transported with rack of 60 mm in height. (7) Shipping weight of chiller is the weight, including the weight of rack, but not the weight of solution. (8) The material of tubes in Absorber and Condenser is S31603 (316L), but the material of tube-sheet and water box is still carbon steel. (9) The overall dimensions (L x W x H) for shipping are about 6790x2850x3870(mm).