Professional Documents
Culture Documents
SATEC Catalog 2009 Online
SATEC Catalog 2009 Online
SATEC Catalog 2009 Online
E RG SO
EN LU
L TI
A
O
T
TO
NS
EM720
Revenue
Metering
& Power
Quality
Revenue Metering
& Power Quality
al Di
s tri st
du rib
In ut
i
on
l
ia
nt
BFM136 ezPAC
id e
Multi-Tenant SA300
es
Sub-Metering
al &R
S
erci
EL
ER
Comm
Trans
EC
CO NSUM
TRIC UT
mis
sion
Generators
IL
RG
I T IE
E
EN
S
Go
ve r
nm
n
en
tio
t&
ra
ne
Pu
Ge
c
bl
Se
i
rv
i ce
s
Power Quality
PM172 Series
BFM136
PM174 / PM175
ezPAC SA300
eXpertmeter EM720
ENERGY MANAGEMENT
WEB SERVICE
eXpertpowerTM
Test
Quality Approvals
Standards Compliance
SATEC is committed to uncompromising compliance with the highest requirements in the energy field.
SATEC devices comply with the most demanding international standards. Standard compliance is tested
by world acknowledged independent labs.
POWER METERS POWER QUALITY POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
ANALYZERS REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
Contents
POWER METERS The Experts in Energy Management
PM130 PLUS Series 4-5 Technological excellence, innovation, quality and a commitment to
PM172 Series 6-7 customer service place SATEC at the forefront of the energy industry.
SATEC has been a proven solutions-oriented global leader in the
POWER QUALITY ANALYZERS research, development and manufacturing of energy management
PM175 / RPM075 / RDM175 8-9 systems since 1987. With two decades of rich experience in energy
PM174 / RPM074 / RDM174 10-11 management, SATEC provides total solutions for customer applications
worldwide. Our greatest strength lies in our deep technological
POWER QUALITY REVENUE METER expertise and our ability to provide flexible solutions for a wide range
eXpertmeterTM EM720 12-13 of customer applications.
SUBSTATION AUTOMATION
Application-Based Solutions
ezPACTM SA300 / RDM LED / RDM312 14-15
SATECs device product line serves both energy utilities and energy
consumers in various fields. Our application-based product line includes
INTEGRATED SOLUTIONS
devices spanning from basic power meters up to high performance
BFM136 16
eXpertpowerTM 17-19 revenue meters with advanced power quality capabilities. All SATEC
eXpertManagerTM 17 devices comply with world-acknowledged regulations and are supported
by our energy management software.
Panel Cutouts
stage of the products lifetime. Our quality system is ISO9001:2000
certified.
Global Distribution
SATEC exports to over 40 countries worldwide throughout Europe,
North and South America, Asia and Africa. Our worldwide distribution
Dual panel mounting: round & square
network provides local marketing service and prompt professional
support.
Hz (50, 60)
The PM130 PLUS series provides a cost- support of the industry standard DNP
Unbalance: V, A effective substitute for numerous V3.0 and Modbus RTU protocols, as
analog meters used by industrial, well as its I/O capabilities (using DI/DO
Max. Amp Demand
commercial and utility customers for module).
Max /Min V-Demand basic power metering. The PM130 PLUS The PM130 PLUS series consists of two
devices are multifunctional three-phase basic models providing digital
Max /Min: V, A, AN, Hz
power meters. The PM130EH PLUS measurements of more than 80
Hz (25, 400) model also offers basic revenue electrical parameters locally, and more
metering. than 100 electrical parameters via RS485
kW, kVAR, kVA, PF
The PM130 PLUS is widely integrated interface.
kW, kVA Demands: Accum; Sliding in panel boards and SCADA systems. The PM130 PLUS modular approach
Power
With the addition of the unique TOU enables users to assemble a system
kW, kVA Demands: Predicted; Max
module, the PM130EH PLUS answers meeting their specific needs. The wide
kVAR: Accum; Slid; Pred; Max the needs of revenue metering choice of plug-in modules includes
applications. It is also suitable for utility digital I/O, analog output, TOU,
Max/Min: kW, kVAR, kVA
substation automation because of its Ethernet and Profibus.
kWh, kVARh, kVAh
Ethernet or Profibus
TDD(I) BASIC POWER QUALITY CONTROL 4 analog outputs
Harmonics (up to the 40th) TOUhigh precision clock + 4 digital
K-Factor Voltage and current THD coefficients inputs + Time-of-Use tariffs for
Displacement PF Time labeled max/min values revenue metering
High Speed Programmable Relay * * REAL TIME CLOCK Dual panel mounting:
I/O Programmable
Built-in clock and calendar functions Round 4; Square 96x96 DIN
Digital Output (Relay Output, Alarm, Trip) 2* 2*
Digital Inputs 4* 4*
[* Available with PM130 PLUS plug-in modules (1 module per device)]
Analog Outputs 4* 4*
RS485
Solid state (2 form A) 250VAC/400VDC 0.15A
RS232 /485
RS422 /485
RS232 /422/485
4
POWER METERS POWER QUALITY POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
ANALYZERS REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
Non-Volatile Memory
Event Log
Data Log
Waveform Log
Transient Record
Symmetrical Components
PM130EH PLUS Power Meter Voltage Variations EN50160 Log
Or EN50160
Fault Current
Energy
Harm.
Harmonic Energies kWh, kVAh
Harmonic Spectrum
Directional Harm. Flows [kW]; [kvar]
Voltages HD [V]
Interharmonic Calculation
Ethernet Port
USB Port
Profibus DP
IRIG-B
5
172E 172P
A, AN
Basic Measurements
Hz (50, 60)
Unbalance: V, A
Hz (25, 400)
Digital Output (Relay Output, Alarm, Trip) 2 The PM172 series includes a choice of built-in communication platforms, such
as modem, Ethernet, Profibus DP, and serial communication.
Digital Inputs 2
Analog Outputs 2
Analog Inputs 2
Basic Communication
RS485
RS232 /485
RS422 /485
RS232 /422/485
Number of Ports 2
6
POWER QUALITY POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
ANALYZERS REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
172E 172P
Event Log
Energy
Harm.
COMMUNICATION
2 independent communication ports Harmonic Energies kWh, kVAh
(RS232, RS422, RS485, modem, Ethernet, Profibus DP)
Protocols: Modbus RTU, ASCII, DNP 3.0 Voltages & Currents HD
Harmonic Spectrum
ISOLATION Directional Harm. Flows [kW]; [kvar]
Full galvanic isolation of voltage and current measuring circuits6 kV Impulse
Voltages HD [V]
Currents HD [A]
Interharmonic Calculation
Dual panel mounting: Round 4; Square 96x96 DIN
Auxiliary AC Current Inputs
Aux. Inputs
Profibus DP
RDM172 Remote Display
The RPM072 can be interfaced with Remote Display IRIG-B
RDM172 via an RS485 communication port, or added
as a second display port for the PM172 series. Dual Power Supply
Add
(Main / Backup)
7
V
175/
075
IEC Advanced Power
A, AN
Basic Measurements
Hz (50, 60)
Unbalance: V, A
0 16 0
5
Max. Amp Demand
Hz (25, 400)
Time of Use (TOU) The Advanced Power Quality Analyzer PM175 is a compact, multifunctional three-
phase power and revenue meter equipped with advanced power quality analysis
Pulse Inputs capabilities. The PM175 has been developed to answer the needs of a wide range
Revenue Metering IEC 62053-22/ANSI C12.20 Class of users within the IEC Market: substation operators, electrical energy system
0.2S
integrators, generator users, industrial and commercial energy consumers. This
THD(U), THD(I)
Total Harmonic
analyzer covers the entire range of applications demanding high performance power
TDD(I) quality monitoring and root cause analysis.
The PM175 provides the full range of power quality monitoring capabilities with
K-Factor built-in EN50160 statistics and reports. The PM175 allows both suppliers and consumers
Displacement PF to monitor the quality of outgoing or incoming electric power. This enables power
suppliers to prepare timely corrective action, and helps consumers prevent equipment
High Speed Programmable Relay damages caused by power quality issues.
I/O Programmable
Digital Output (Relay Output, Alarm, Trip) 2 Two communication ports allow local and remote data acquisition.
Digital Inputs 2
Analog Outputs 2
Analog Inputs 2
Basic Communication
RS485
RS232 /485
RS422 /485
RPM075
RS232 /422/485
Remote Power Meter
Number of Ports 2 The RPM075 Remote Power Meter is a non-
display power meter providing a solution for
Modbus RTU + ASCII
cases where there is no available space for
Protocol
Comm.
8
POWER QUALITY POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
ANALYZERS REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
1 Mb Non-Volatile Memory
Event Log
(FULL PQA)
MULTIFUNCTIONAL THREE-PHASE POWER METER Time Stamps Resolution
Voltage, current (including neutral current), power, energy, power factor, frequency,
voltage/current unbalance, load profile Data Log
Energy
Harm.
ALARM AND CONTROL FUNCTIONS Harmonic Energies kWh, kVAh
16 programmable set points
2 programmable relay outputs 3A, 250V Voltages & Currents HD
Harmonic Spectrum
2 digital inputs
2 optional analog inputs or outputs Directional Harm. Flows [kW]; [kvar]
Voltages HD [V]
COMMUNICATION
2 independent communication ports
Currents HD [A]
(RS232, RS422, RS485, modem, Ethernet, Profibus DP)
Protocols: Modbus RTU, ASCII, DNP 3.0 Interharmonic Calculation
Built-in Modem
Dual panel mounting: Round 4; Square 96x96 DIN
Special Communication
Ethernet Port
USB Port
Profibus DP
9
V
174/
074
ANSI
A, AN
Advanced Power
Basic Measurements
Hz (50, 60)
Unbalance: V, A
1 15 9
Max /Min V-Demand
IE E E
Max /Min: V, A, AN, Hz
Hz (25, 400)
quality monitoring and root cause analysis. The extensive features of the PM174
TDD(I) make it ideal for applications such as feeder, switch gear monitor, revenue metering
and billing, power quality and utility SCADA. It is also highly suitable for substation
K-Factor automation because of its support of industrial standard DNP 3.0 and Modbus RTU
Displacement PF protocols.
The PM174 provides the full range of power quality monitoring capabilities,
High Speed Programmable Relay implemented with the IEEE1159 specifications in mind. The PM174 allows both
I/O Programmable
Digital Output (Relay Output, Alarm, Trip) 2 suppliers and consumers to monitor the quality of outgoing or incoming electric
power. This enables power suppliers to prepare timely corrective action, and helps
Digital Inputs 2
consumers prevent equipment damages caused by power quality issues. Two
Analog Outputs 2 communication ports allow local and remote data acquisition.
Analog Inputs 2
Basic Communication
RS485
RS232 /485
RS422 /485
RPM074
RS232 /422/485
Remote Power Meter
Number of Ports 2 The RPM074 Remote Power Meter is a non-
display power meter providing a solution for
Modbus RTU + ASCII
cases where there is no available space for
Protocol
Comm.
10
POWER QUALITY POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
ANALYZERS REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
174/
074
1 Mb Non-Volatile Memory
Event Log
(FULL PQA)
Time Stamps Resolution
Data Log
MULTIFUNCTIONAL THREE-PHASE POWER METER
Voltage, current (including neutral current), power, energy, power factor, frequency,
Energy
Harm.
Logging capability for more than 100 parameters
Logging parameters with real-time stamps Harmonic Energies kWh, kVAh
Harmonic Spectrum
16 programmable set points
Directional Harm. Flows [kW]; [kvar]
2 programmable relay outputs 3A, 250V
2 digital inputs
Voltages HD [V]
2 optional analog inputs or outputs
Currents HD [A]
COMMUNICATION
2 independent communication ports Interharmonic Calculation
(RS232, RS422, RS485, modem, Ethernet, Profibus DP)
Auxiliary AC Current Inputs
Aux. Inputs
Built-in Modem
Special Communication
Ethernet Port
Dual panel mounting: Round 4; Square 96x96 DIN
USB Port
(Main / Backup)
11
720
A, AN
High Performance
Basic Measurements
Hz (50, 60)
Unbalance: V, A
Hz (25, 400)
!
kW, kVAR, kVA, PF NEW
kW, kVA Demands: Accum; Sliding
Power
Pulse Inputs
Class
High Performance Revenue Meter
Revenue Metering IEC 62053-22/ANSI C12.20
Cutting Edge Power Quality Analyzer
0.2S
THD(U), THD(I)
Total Harmonic
Displacement PF
RS485
The eXpertmeter TM all-in-one solution has been developed to comply with the most
RS232 /485 demanding customer requirements in energy generation and distribution (power
stations, electric companies, substation operators, electric energy system integrators)
RS422 /485
and in energy consumer segments (industrial and commercial). The eXpertmeter TM
RS232 /422/485 can serve as a main revenue meter or test meter to manage advanced energy supply
contracts that include a commitment to the most demanding power quality standards.
Number of Ports 2
The eXpertmeter TM can be used to resolve disputes between electric energy suppliers
Modbus RTU + ASCII and consumers regarding power quality standard violations.
Protocol
Comm.
This device provides the most advanced communication capabilities, such as built-in
DNP3.0 + Modbus RTU
infra-red port, serial communication (RS-232/RS-485), Ethernet and USB. With its hot
DNP3.0 + ASCII + Modbus RTU swapping field replaceable modules, the eXpertmeter TM can be tailored to specific
needs by adding additional communication capabilities, I/O capabilities or auxiliary
C.B.
12
POWER QUALITY SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
REVENUE METER AUTOMATION SOLUTIONS & PORTABLE ANALYZER
720
Non-Volatile Memory
Revenue Meter
8 Mb
Event Log
(FULL PQA)
MULTI-TARIFF REVENUE METER EVENT/DATA LOG
Meets 0.1% accuracy Event statistics complimented by Data Log
Class 0.2S Precision according to waveform recording
Energy
Voltage and current THD coefficients
Harm.
Flicker measurement according to IEC Hot swap modules
Harmonic Energies kWh, kVAh
61000-4-15 Ethernet (100Mb/s), USB & RS232/485
Waveform recording, up to 1024 IRIG-B & RS232 /485 Voltages & Currents HD
Harmonic Spectrum
samples/cycle GSM /GPRS (Class 10)
Protocols Directional Harm. Flows [kW]; [kvar]
TRANSIENT RECORDER Master/Slave Modbus Binary & ASCII
Records fast transients overvoltages Modbus RTU Voltages HD [V]
>17 ms DNP 3.0 over IP
Transients measured relative to ground TCP /IP
Currents HD [A]
Measures up to 2 kV pulses SMTP (outgoing mail)
Interharmonic Calculation
Optional IEC 61850 protocol
MULTIFUNCTIONAL THREE-PHASE Auxiliary AC Current Inputs
Aux. Inputs
Ethernet Port
USB Port
IRIG-B IRIG-B
RS232/485 Ethernet
USB
RS232/485
Dual Power Supply
Add
(Main / Backup)
13
V
ezPAC
Hz (50, 60)
Unbalance: V, A
Hz (25, 400)
combined into a single powerful unit. ezPACTM unites advanced control and automation
functions, intelligent fault-recorder, power quality and sequence of events (SOE)
TDD(I)
with automatic analysis and reports. It also offers revenue metering, back-up
K-Factor protection equipment and control devices to provide a complete solution for substation
and industrial automation. The ezPACTM is suitable for retrofit as well as for new
Displacement PF
utility projects.
High Speed Programmable Relay This instrument is an ideal cost-effective means to automating an electrical substation
I/O Programmable
Digital Output (Relay Output, Alarm, Trip) 32 with existing electro mechanical (EM) relays. The ezPACTM Series extends the life
expectancy of EM protection relays for many years by providing the information
Digital Inputs 48 lacking from these highly reliable devices without interfering with the protection
Analog Outputs 16 scheme.
Analog Inputs 16
Display Modules
Basic Communication
RS485
RS232 /485
RS422 /485
14
SUBSTATION INTEGRATED COMMUNICATION DEVICE TABLE
AUTOMATION SOLUTIONS & PORTABLE ANALYZER
4 Mb+
128 Mb Non-Volatile Memory
(FULL PQA)
Voltage, current (including neutral), power, Pulsed transients detection Time Stamps Resolution
energy, power factor, demands, frequency, (pulse width >150 ms)
Data Log
voltage/current unbalance, load profile Harmonics & inter-harmonics according
1 DC voltage input (up to 300 VDC) to IEC 61000-4-7
Energy
Harm.
time stamps ports (RS232 & RS422 /485)
Built-in 4 Mb logging memory, up to 128 Infrared port Harmonic Energies kWh, kVAh
Mb (option) Built-in modem
Ethernet Voltages & Currents HD
Harmonic Spectrum
MULTI-TARIFF REVENUE METER USB port
Directional Harm. Flows [kW]; [kvar]
Class 0.2S Precision according to Protocols: Modbus RTU & ASCII, DNP 3.0,
IEC 62053-22 TCP /IP Voltages HD [V]
Time of Use (TOU) tariffs Optional IEC 61850 protocol
Currents HD [A]
ADVANCED POWER QUALITY ANALYSIS
Power quality according to Interharmonic Calculation
IEC 61000-4-30 Class A
5 Auxiliary AC Current Inputs
Aux. Inputs
Profibus DP
IRIG-B
15
Multi-Tenant Sub-Metering
Integrated Solutions for Energy Consumers
Provides a complete set of energy and demand Data access and TOU via PAS software
data on multi-tariff basis for billing purposes (see pg. 18 for more information about PAS)
Class 0.5S precision in revenue metering Web-based energy management with
Meter sealing option for voltage and current eXpertpowerTM providing online data access
inputs Compact design for easy installation within
Current and voltage monitoring existing or new electric panelboards
12 3-phase channels Durable design for tamper resistance
18 2-phase channels Communication platforms
36 1-phase channels Built-in serial RS485
Any combination of the above Optional: modem, Ethernet, wireless
Compliant with ANSI and IEC specifications Real Time Clock
LCD display for on-site access, providing 30 Event and data logging
channels of consumption readings for each Flash memory 8 Mb
tenant
Current Transformers
Options
12mm, 0.47 23mm, 0.91 26mm, 1.02 Split Core CT
100A 100A 400A 16mm, 0.63
100A
16
INTEGRATED COMMUNICATION DEVICE TABLE
SOLUTIONS & PORTABLE ANALYZER
eXpertManagerTM
eXpertManagerTM powered by the Power Rich System from BCI
Technologies, is an integrated power quality SCADA system for
commercial, industrial, and utility power monitoring and control.
eXpertManagerTM is a real time SCADA monitoring and control system
with predictive demand metering, advanced power quality, demand
response and carbon monitoring capabilities. eXpertManagerTM is an
add-on automation solution that supports a wide range of SATEC and
third party products, to minimize installation and operational costs.
The eXpertManagerTM system provides commercial and industrial
customers a tool to successfully monitor power quality, individually
meter tenants or production areas, reduce energy demand and reduce
energy costs.
The eXpertManagerTM system is a Windows-based SCADA system
specifically designed to use industry standard open protocols like OPC,
Modbus, and DNP3.0. The eXpertManagerTM system also features a
scalable architecture with built-in mirrored redundancy. The expansion
capability ranges from a single server with 500 data points to multiple
servers with more than 1,000,000 data points, distributed over a wide
area communicating with thousands of devices. The systems inherent performance provide customers an opportunity to reduce electrical
communication ability enables status changes from the field to reach demand before the end of a utility demand period. eXpertManagerTM
an operators display in less than 2 seconds. SATECs predictive demand also provides an integrated web server option for customers who wish
metering capability combined with eXpertManagerTMs system to leverage the Intranet or Internet for data access and system control.
17
Integrated Solution:
Energy Consumer Solutions: System Architecture
& BFM136
r t p ow er.com
.e x p e
www
18
INTEGRATED COMMUNICATION DEVICE TABLE
SOLUTIONS & PORTABLE ANALYZER
FEDERAL
ELECTRICITY
MAINTENANCE
CONSULTING
CUSTOMER
ACCOUNTING
MONITORING
EXECUTIVE
19
PAS SOFTWARE
Sophisticated analysis:
Data logshistorical or current
Trendsindividual or 3 phases together
Trend over time data log or waveform
Trend based on user-selected parameters or limits
Harmonic spectrum
Harmonics power direction
EN50160 comparison tables for HV and LV applications
G5/4 comparison tables for HV and LV applications
Vector analysis/phasor diagram
Automatic power quality and fault categorization
Waveform comparison between sites
ITI (CBEMA) curve
Automatic sort and filter capabilities
Uploading TOU settings
Uploading with variable setpoints
Alarms with variable setpoints
Delta measurement SETUP
Self-test
HARMONICS ANALYSIS
20
COMMUNICATION DEVICE TABLE
& PORTABLE ANALYZER
21
Communication Devices
RSC232 Communications Converter
The RSC232 communications converter, with a built-in power supply, is designed to handle up to 31 IEDs
connected via RS485 up to 1200 meters/4000 feet. It can be powered from AC/DC power supply, and permits
easy conversion of RS232 PC signals into full duplex (RS422) or half duplex (RS485) communication.
Din/Wall Mounting.
Portable Analyzer
EDL175/EDL174XR Portable Analyzer
22
DEVICE TABLE >>
Energy management web service offering billing, power quality analysis & more
V & I Captures
Waveform Log
Device Comparison Table
Time Stamps
Historical Log
Data Log
Event Log
128
Non-Volatile Memory (Mb)
4/
1
8
RTC Real Time Clock
K-Factor
Distortion
Harmonic
TDD (I), %
Total
THD (I), %
THD (U), %
*
TOU Tariffs
Revenue Metering
Pulse Inputs
*
0.2S
0.2S
0.2S
0.2S
0.2S
0.5S
0.5S
IEC62053-22 / ANSI C12.20 (Class)
Measurements
PF
Power
ezPACTM SA300
eXpertmeterTM
PM130EH PLUS
PM130P PLUS
PM172P
PM172E
BFM136
PM175
PM174
COMPARE INSTRUMENTS
24
25
*
Additions Backup Power Supply
*
IRIG-B
Special Communication
*
GSM / GPRS
*
Profibus DP
IR
*
USB
*
*
Ethernet Port TCP / IP
Built-in Dial-up Modem
DC Voltage
1
Auxiliary
Inputs
AC Voltage
1
AC Current
4
DNP3.0 + Modbus (RTU + ASCII)
Protocols
1+1*
No. of Ports
7
2
2
Basic Comm.
32 16 48 16
Analog Inputs
+2*
2* 4* 4*
2* 4* 4*
Digital Inputs
4
Analog Outputs
2*
Relay Output (SS /EM)
2
Capacitor Capacitor Bank Control
Harmonic Powers kW, kVA
Individual Harmonics
Interharmonic Calculation
Directional Harm. kW, kVAR
Currents, HD, A
Voltages HD, V
Voltage / Current HD, %
1/2 Cycle RMS Calculation
Fault Current
Accd. to IEEE 1159 & IEEE 519
EN50160 Reports
Symmetrical Components
Dips, Sags, Swell Recording
10 Milltown Court
Distributor
Union, NJ 07083, USA
Contact us at satec@satec-global.com
www.satec-global.com
BB0131 REV.A3