Yokogawa Corporation of America

WT500 BASIC UNCERTAINTY CALCULATION

Input the Voltage & Current Readings and Ranges, Frequency and Power Factor: Input Data

Voltage: Reading 300


Range 300
Current: Reading 10
Range 10
1P-2W 3P-3W 3P-4W
Watt: Reading 3000 5196 9000
Range 3000 6000 9000

Frequency: kHz 0.05 Power Factor 1

Voltage Current Watt Watt Watt


Frequency Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Volts Amps Watts/Element 3P-3W 3P-4W

DC 0.6000 0.0200 6.0000 N/A N/A


0.5< f < 45 Hz 0.9000 0.0300 15.0000 27.5880 45.0000
45 < f < 66 Hz 0.6000 0.0200 6.0000 11.1960 18.0000
66 < f < 1 kHz 0.9000 0.0300 12.0000 22.3920 36.0000
1 kHz < f < 10 kHz 0.7575 0.0205 7.1905 14.7927 21.3715
10 kHz < f < 50 kHz 1.2060 0.0504 -255.6300 -444.0724 -777.0900
50 kHz < f < 100 kHz 1.2060 0.0504 -255.6300 -444.0724 -777.0900

NOTE: Fields in Green are Frequency dependent.


Input correct frequency in Cell C16 for each frequency range calculation.

NOTE: Watt Uncertainty Calculation includes additional uncertainty due to Power Factor
Enter Power Factor Value; 0.0 < PF < 1.0; in Cell E16
DO NOT ENTER ANY VALUES IN TABLE BELOW
Power Factor j j Power Factor Uncertainty
cos( j) (Radians) (Deg) tan( j) d × tan( j)
  (% Reading)
Model WT500
0.0 < PF < 1.0
1 0.0000 0.0000 0.0000 0.0000 %
PF = 0 Additional Reading Error
45 < f < 66 Hz 6.00 Watts/Element

WT500, d = 0.20%
0.2 0.2
1000
600
300
150
100
60
30
15

40
20
10
5
2
1
0.5