SiteSentinel® SiteSentinel® Integra 100™ Console Features

Integra 100™ Console


Provides complete tank monitoring,
inventory management and environmental- Part of the
compliance testing through the
incorporation of the latest computer
technology, which allows users to view
data remotely from anywhere in the world. family of products
The SiteSentinel® Integra 100™ has been
designed to lower installation costs by
reducing the number of wires to the
probes and sensors that are connected
to its internal I.S. module. In addition, Easy To Connect S
B
Convenient
U
all digital devices are automatically
detected and configured by using the
touch-screen interface, making it one of Easy To Use Savings
the easiest ATG systems in the industry
to install, configure and use.
u L
 arge color touch-screen display u D
 isplays gross and net-corrected tank
The SiteSentinel® Integra 100™ console gives one-touch access to real-time volume, product level, water level and
has been designed to reliably provide inventory data, delivery status, temperature for individual tanks
connectivity now and in the future. alarm conditions and leak-detection u C
 onfigurable to meet localized
Available ports include: Ethernet, USB information – all accessible from a settings (Date/Time formats and
RS-232 and modem. It is also one of the single cockpit view Metric/English units)
u S
 tatisticalLeak Detection (SLD)
easiest tank gauges to use, requiring u P
 rovides programmable correction
– optional advanced leak-testing factors for restrapping tanks
the least amount of training and menu
technology – provides continuous (2,000 points)
navigation to access critical data.
automatic in-tank leak-detection
u Includes address book of contacts
operation, with no need to schedule
to whom the unit can send text
test times or shut down tanks
messages, fax and/or emails on any
u P
 rogrammable Automatic Leak alarms and events
Detection (ALD) performs daily,
u A
 ble to schedule reports to
weekly, monthly and annually
automatically run at specific times
required static leak tests when the
system detects a quiet time u C
 ommunicates with industry-
u Integral
standard, third-party POS protocol
4-channel
and displays format commands
multi-drop I.S. module
u C
 ompliance calendar accessible
u Internal power supply works
with a single touch
between 96-264 VAC, covering
all global requirements u N
 on-volatile memory for event
u International
storage up to 10 years
user-friendly icons
follow guidelines in MIL-STD-1472

Listings and
Certifications

243 6900 Santa Fe Drive Hodgkins, Illinois, USA 60525 Phone: 708 485-4200 Fax: 708 485-7137
Additional Features Leak Test Certification Specifications
u M
 onitorsup to 16 probes or EPA Static Leak and Dimensions: 14.5 inch W x 12 inch H x
64 sensors, or a combination Continuous Test Certified 4 inch D (37 cm x 30 cm x 10 cm)
u O
 ptional Tank
(ATGS & CITLDS Methods):
Overfill Alarm Operating Temperature: 32°F to 122°F
u 0
 .2 gph (0.76 L/hr) Statistical Leak (0°C to 50°C)
u A
 vailable output module provides
multi-purpose relays, which can be Test at 397,000 gallons (1,502,809
Humidity: Non-Condensing (Max 95%)
used for outputs such as overfill liters)/month throughput for single-
tank, 2-tank or 3-tank manifold Typical Mounting Location: Indoor,
alarms, sensor alarms or
installations with a 30,000-gallon Non-Hazardous Area
STP positive shutdown
(113,562 liters) combined maximum Power Requirements: 96-264 VAC,
u O
 ptional density measurement
capacity 50/60 Hz
sensor has the capability to monitor
u 0
 .2 gph (0.76 L/hr) Static Leak Test
product quality Communication Ports: One (1) x
u D
 ownloadable and Flash upgradeable
u 0
 .1 gph (0.38 L/hr) Static Leak Test Ethernet, Two (2) x RS-232, Two (2) x
software for easy updates USB, Two (2) internal USB, One (1) x
modem (optional)
Standard one (1) output and one (2)
input internal relay connection

SiteSentinel® Integra 100™ Internal I.S. Barrier • One (1) four-channel I.S. Barrier
• Maximum of 16 Model 924B Probes
• Maximum of 64 IntelliSense™ Sensors

Up to 4 Multi-Drop 924B Probes

1 Model 924A
Standard Probe Any combination of up to16 IntelliSense™ Smart Sensors

NOTE: See OPW Fuel Management Systems’ website at www.opwglobal.com for detailed product
literature, manuals and sales representative contact information for your area.

www.opwglobal.com 244