Remote I/O Terminal Basic Units Remote I/O Terminal Expansion Unit
Model number Specification Model number Specification
DRT2-ID16 16 inputs, NPN XWT-ID08 8 expansion inputs, NPN
DRT2-ID16-1 16 inputs, PNP XWT-ID08-1 8 expansion inputs, PNP
DRT2-OD16
DRT2-OD16-1
16 outputs, NPN
16 outputs, PNP
XWT-OD08
XWT-OD08-1
XWT-ID16
8 expansion outputs, NPN
8 expansion outputs, PNP
16 expansion inputs, NPN
Smart Slaves
One Basic Unit and one Expansion Unit can be combined freely.
XWT-ID16-1 16 expansion inputs, PNP
XWT-OD16 16 expansion outputs, NPN
Dimensions
XWT-OD16-1 16 expansion outputs, PNP
115
XW T-ID16(-1)/O D16(-1)
Remote I/O Terminal Expansion Units 43.9 XW T-ID08(-1)/O D08(-1)
Model number
XWT-ID16 -1
XWT-ID16
XWT-OD16 -1
50
XWT-OD16
XWT-ID08 -1
XWT-ID08
XWT-OD08 -1
XWT-OD08
29.9
13 16-point models: 94 3.1 49.7
8-point models: 66
OMRON's DRT2-series Smart Slaves do not just input and output ON/OFF signals. They collect a variety All data can be converted to electronic format and, Information monitoring for
of value-added information to help increase the rate of operation without changing the wiring for by combining with an OMRON PLC (CS/CJ Series), each Slave
existing DeviceNet networks. In particular, they allow the separation of control systems and checked directly from Ethernet or the Internet to
maintenance systems so that maintenance systems can be created independently of control systems. allow remote maintenance.
PLC
Maintenance is
required for
2 Easy-to-view
Display
Configurator
cylinder 23A in
inspection line A!
Control I/O
Configurator's maintenance mode screen Slave comment
The Configurator's screen images may be changed without notice.
Operating time, contact operation Status confirmation using the status icon
counter
Maintenance information
DeviceNet
Configurator Operating time monitor
1 3
Unit conduction time monitor
The Slave can hold comments, startup Network power voltage monitor
123 Sensor
4 5.. DRT2-series
MS NS NODE ADDRESS
DRT2-ID16 ET-OD16
MS NS NODE ADDRESS
DRT2-ID16
MS NS NODE ADDRESS
DRT2-ID16
MS NS NODE ADDRESS
DRT2-ID16
MS NS NODE ADDRESS
DRT2-ID16
MS NS NODE ADDRESS
DRT2-ID16
Smart Slave
Smart Measuring Smart Counting The cylinder's It m ight be time Is the I/ O W hat w as the
The Slave Unit represents By counting the number of
speed is for a sw itch pow er supply cause
machine operating time and ON/OFF operations and the incorrect ! inspection! turned ON? of the error?
operational changes as data, total operating time, the Slave
enabling monitoring without Unit can provide notification Operating time Contact operation I/ O pow er status Comm unication error
increasing the load between when maintenance is required. Cylinder monitor counter (See note .) monitor history mon itor
controllers.
N ote : The contact operation counter function and the unit conduction time monitor function cannot be used simultaneously.
2 3
Internal Circuit Diagrams W iring Diagrams
Causes for communication errors can be Remote I/O Terminals (Models with 16 Transistor Inputs) Remote I/O Terminals (Models with 16 Transistor Inputs)
DRT2-ID16 (NPN)/DRT2-ID16-1 (PNP) DRT2-ID16 (NPN)/DRT2-ID16-1 (PNP)
monitored.
What happened DRT2-ID16 (NPN) DRT2-ID16-1 (PNP) DRT2-ID16 (NPN) DRT2-ID16-1 (PNP)
when the 24 VDC
10 11 12 13 14 15 16 17 18
24 VDC
10 11 12 13 14 15 16 17 18
Physical layer
Physical layer
error occurred? CAN H 0 CAN H 1
1
G
2
0
3
2
4
4
5
6
6
8
7
10
8
12
9
14
1
G
2
0
3
2
4
4
5
6
6
8
7
10
8
12
9
14
DRAIN 1 DRAIN
Internal circuit
Information (i.e., communication error code and network
Internal circuit
Smart Slave Status when error occurred CAN L
V–
Photocoupler CAN L
V–
Photocoupler
power voltage at the time) for four previous errors can be MS NS NODE ADDRESS
– + – +
First time
Blue (Black)
Brown (White)
Blue (Black)
Black (White)
Brown (Red)
G
recorded in the Slave. This error history can be read from
Brown (White)
Blue (Black)
Brown (Red)
Black (White)
Blue (Black)
I/O power supply I/O power supply
Non-insulated Non-insulated
DC-DC DC-DC
Smart Slaves that are removed from the network when Second time DRT2-ID16 converter
G
converter
Three-wire sensor with
Three-wire sensor with Two-wire sensor
Two-wire sensor NPN output
correcting an error, enabling more effective maintenance. Third time Recorded in NPN output
(photoelectric sensor or
proximity sensor)
(e.g., limit switch) (photoelectric sensor or
proximity sensor)
(e.g., limit switch)
the Slave
Fourth time Remote I/O Terminals (Models with 16 Transistor Outputs) Remote I/O Terminals (Models with 16 Transistor Outputs)
DRT2-OD16 (NPN)/DRT2-OD16-1 (PNP) DRT2-OD16 (NPN)/DRT2-OD16-1 (PNP)
DRT2-OD16 (NPN) DRT2-OD16-1 (PNP) DRT2-OD16 (NPN) DRT2-OD16-1 (PNP)
Physical layer
10 11 12 13 14 15 16 17 18
Physical layer
Photocoupler Voltage Photocoupler 10 11 12 13 14 15 16 17 18
CAN H step- CAN H 0 V 1 3 5 7 9 11 13 15 V 1 3 5 7 9 11 13 15
V 24 VDC
DRAIN down DRAIN
0 1
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Internal circuit
Internal circuit
V– V–
Photocoupler Photocoupler
Easy M ounting and Dismounting of Terminal Blocks XWT-ID08 (NPN) XWT-ID08-1 (PNP) XWT-ID08 (NPN) XWT-ID08-1 (PNP)
24 VDC 24 VDC
be mounted and 0 1
inserting post terminals. checking using a tester. 1 1
G
2
0
3
2
4
4
5
6
1
G
2
0
3
2
4
4
5
6
dismounted with
Internal circuit
Internal circuit
Photocoupler
Photocoupler
Blue (Black)
Brown (White)
Blue (Black)
Black (White)
Brown (Red)
Brown (White)
Blue (Black)
Brown (Red)
Black (White)
Blue (Black)
Input Filter Fu nction G
I/O power supply I/O power supply
The influence of noise can be removed using the ON Three-wire sensor with Two-wire sensor
Three-wire sensor with
NPN output
NPN output
than the communications time can be handled using the Remote I/O Terminal Expansion Units (Models with 8 Transistor Outputs) Remote I/O Terminal Expansion Units (Models with 8 Transistor Outputs)
Basic Units
OFF response time. XWT-OD08 (NPN)/OD08-1 (PNP) XWT-OD08 (NPN)/OD08-1 (PNP)
Expansion Units XWT-OD08 (NPN) XWT-OD08-1 (PNP) XWT-OD08 (NPN) XWT-OD08-1 (PNP)
Function for Handling Sensor Inrush Current
Easy Expansion w ith Expansion U nits In order to prevent incorrect input due to inrush current V 24 VDC 24 VDC
The Smart Slaves can be expanded easily by freely Voltage
24 VDC
Slave can be set not to accept input for 100 ms after the 1 1 2 3 4 5 1 2 3 4 5
Internal circuit
Internal circuit
G 0 2 4 6
mounting. This means less wiring work is required. G 0 2 4 6
Voltage
step- G – + – +
down
I/O power supply I/O power supply
10 11 12 13 14 15 16 17 18 10 11 12 13 14 15 16 17 18
Vibration resistance 10 to 50 Hz, 0.7-mm double amplitude ON voltage 15 VDC min. (between each input 15 VDC min. (between each input Photocoupler V 24 VDC V 1 3 5 7 9 11 13 15 V 1 3 5 7 9 11 13 15
V 24 VDC Photocoupler
2 terminal and V) terminal and G) 0
Shock resistance 200m/s 0
1
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
G 0 2 4 6 8 10 12 14 G 0 2 4 6 8 10 12 14
5 VDC min. (between each input 5 VDC min. (between each input 1
Dielectric strength 500 VAC (between isolated circuits) OFF voltage
Internal circuit
Internal circuit
terminal and V) terminal and G) Photocoupler
Photocoupler
Insulation resistance 20 M min. (between isolated circuits) OFF current 1.0 mA max. per point (at 24 VDC)
Ambient operating temperature –10 to 55 C – + – +
Blue (Black)
Brown (White)
6.0 mA max. per point at 24 VDC; 3.0 mA max. per point at 17 VDC
Blue (Black)
Black (White)
Brown (Red)
Input current
Brown (White)
Blue (Black)
G
Brown (Red)
Black (White)
Blue (Black)
I/O power supply I/O power supply
Ambient operating humidity 35% to 85% ON delay time 1.5 ms max. G
Ambient atmosphere No corrosive gases OFF delay time 1.5 ms max. Three-wire sensor with
NPN output
Two-wire sensor
Three-wire sensor with
NPN output
Two-wire sensor
(e.g., limit switch) (e.g., limit switch)
(photoelectric sensor or (photoelectric sensor or
Ambient storage temperature –20 to +65 C Number of points per common 16 points per common proximity sensor) proximity sensor)
Mounting method 35-mm DIN track mounting Remote I/O Terminal Expansion Units (Models with 16 Transistor Outputs) Remote I/O Terminal Expansion Units (Models with 16 Transistor Outputs)
50 N (in directions other than the DIN track direction), Output Speci fications XWT-OD16 (NPN)/OD16 -1 (PNP) XWT-OD16 (NPN)/OD16-1 (PNP)
Mounting strength
10 N (in the DIN track direction)
Item Specification XWT-OD16 (NPN) XWT-OD16-1 (PNP)
Screw tightening torque M3 (power supply, I/O terminals): 0.3 to 0.5 N•m XWT-OD16 (NPN) XWT-OD16 -1 (PNP)
Model number DRT2-OD16 DRT2-OD16-1
V 24 VDC 24 VDC 24 VDC
Internal I/O common processing NPN PNP Photocoupler Voltage Photocoupler
10 11 12 13 14 15 16 17 18 10 11 12 13 14 15 16 17 18
step- V 24 VDC 0
V 1 3 5 7 9 11 13 15 V 1 3 5 7 9 11 13 15
Number of I/O points 16 outputs down
0 1
1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Internal circuit
Internal circuit
Rated output current 0.5 A per point, 4.0 A per common G 0 2 4 6 8 10 12 14 G 0 2 4 6 8 10 12 14
1.2 V max. (0.5 A between each 1.2 V max. (0.5 A between each
Residual voltage Photocoupler Photocoupler
output terminal and G) output terminal and V)
Voltage
Leakage current 0.1 mA max. step-
G – + – +
down
I/O power supply I/O power supply
ON delay time 0.5 ms max.
G Solenoid Valve Solenoid Valve
OFF delay time 1.5 ms max.
Number of points per common 16 points per common
6 7