I. PROJECT BACKGROUND

PT. Supreme Energy Muara LabohRantau Dedap (“Company”)


is in the process of exploitation of Muara LabohRantau
Dedap geothermal power plant project (“Project”),
located in WestSouth Sumatra, Indonesia. The project
is being developed by PT. Supreme Energy Muara
LabohRantau Dedap (SEMLSERD) and financed by investors
including Asian Development Bank (ADB). Engineering,
Procurement and Construction (EPC) and development
drilling have beenwill be conducted since on early May
2017 2018 and commercial operation date is scheduled
in August 20192020.
In accordance with the Company project requirement for
the accommodation’s power supplypolicy related to
Corporate Social Responsibility, the Company will
build the power supply’s infrastructure forBuilding
and Field of Sports Centercomplete with the supporting
accesories and fixtures inside the accommodation in
Muara LabohRantau Dedap, South SolokLahat Regency,
WestSouth Sumatra on land owned by the Company. In
connection with this, it is necessary work of Design,
Supply & Build of power supply infrastructure called
medium voltage overhead line (Saluran Udara Tegangan
Menengah /SUTM)and Development of Muara LabohNew
Accommodation Camp Sports Center. In this case, the
work of Design of Muara Laboh Sport Center will be
done first.

Page 1 of 14
II. SCOPE OF WORK

The work which shall include in the scope of this


Contract is Civil, Architectural, Structural,
Mechanical and Electrical Designs, Supply, Build &
Testing of Muara LabohRantau Dedap for Sport CenterNew
Accommodation power supply infrastructure (SUTM)
Building (Block-B and Block C Type) in Solok Selatan,
Westand the works will be develop into 2 stages with
the description as follow Sumatra according to
Indonesian national standards with the following
object:

A. StadiumDesign And Drawing


1. Project Description
 Project Name : Design, Supply, and
Build & Testing Pre Fabricated Container
House for Block B and Block C.of Medium
Voltage Overhead Line (SUTM)
 Location : Rantau Dedap Site, Lahat
Regency, South Sumatera Province, Indonesia
 Building Area :
 From GPP powerhouse to accommodation camp
estimated +/- 6 km.PreFab House Block-B
: 296 m2
 PreFab House Block-C : 255 m2
Total Area : 551 m2

2. Plan & Design

Page 2 of 14
a). Data Collection
 Owner Requirement
 Survey Location (Pictures and supporting
Data)
 Interview (if necessary)
 Program Plan
 Concept Plan
 Skecth Idea

b). Working Product:


 RouteFloor Plan drawing (Scale 1 :
100)
 Appearance (Scale 1 : 100)Pole type,
quantity & specification
 Section (Scale 1 :
100)Accessories & specification based on
electrical/ mechanical requirement’s
properties

 3D Perspective (Exterior)

3. Shop Drawing & Others


a). ArchitectureCivil
 FloorRoute Plan of poles
Survey of route to determine poles
staking, poles interface for raising
underground cable, avoid falling trees,
crossing the SUTT transmission line,

Page 3 of 14
slopes, turns maneuver & any other
consideration etc
 Appearance
 Section
 3D Perspective
 Detail Plan for Doors and Windows
 Detail Plan for Walls
 Detail Plan for Floor
 Detail Plan for Plafond
 Detail Plan for Bath Rooms

b). Structure
 Detail Plan for pole’s Foundation &
foundation loads
Detail Plan for Reinforced Steel for Work
Floor
Detail Plan for Work Floor
Detail Plan for Container and its
Modification
Detail Plan for Roof Frame
Detail Plan for Terrace Roof Frame
Detail Plan for Water Tower

c). Mechanical & Electrical


 Diagram of Clean and Waste Water
InstallationPole outline drawing c/w
mechanical & electrical materials/
components & accessories such as AAACS
insulated conductor, OPGW, insulator,
Fuse cut out, mounting components/
Traverse etc based on engineering

Page 4 of 14
proposal, calculation & electrical
requirement.
 Plan of Clean Water InstallationConductor
mounting & components accessories.
 Installation & testing
 \Plan of Waste and Used Water
Installation
 Plan of Water Pumps
 Drawing of MCB Diagram and Lamps Point
 Drawing of Switch Installation
 Drawing of Socket/Jack/Plug-in
Installation

d). Others
 Time Schedule
 Budget Plan for Construction (RAB)
 Component spare part is 10% from total
component/accessories supplied, 1000m
insulated conductor etc

B. Construction
1. General Preparation
 Mobilization and Demobilization (Workers and
Work-Tools and other material)
 Warehouse and ”Direksi Keet” Installation
 Workers Temporary HouseCamp (Bedeng)
 Electrical Line (from PLN or Genset),
electrical source will be provide by the
Owner/SERDcontractor.

Page 5 of 14
2. Construction Work of Block-B and Block-C
a). Preparation Work
 Measurement and Bouwplank worksSite
Survey
 Clearance of Area

b). Procurement and Delivery Container


 Procure of complete equipment, material &
accessories Container (Original), Cap. 20
Feet (80% condition), Dimension 600 x 240
x 250 cm.
 Transporting the Conatinermaterial ,
material & accessories from Jakarta to
Rantau Dedap Site, Lahat Regency, South
Sumatera Province.
 Loading and Unloading of the container
material / equipment using the Forklift
on the Workshop area, Port and Site Area.
 Set and Install the containermaterial,
equipment & accesories at site refer to
design of Prefab Bock-b and Block-C.
 Container Mmodification at site area
refering to the Design and Drawing.

c). Earthwork
 Earthwork for Foundation and Septictank
placement,
 Earth-fill works

d). Foundation & Polesand Work Floor


 Rollag Brick and Sloof Works

Page 6 of 14
 Reinforced steel, concrete pouring and
cement plaster for work floor works
 Concrete foundation type & height
 Concrete loads mounting the conductor,
electrical/ mechanical component &
accessories etc

Walls
Partition Wall Installation ( 2 side and 1 side)
Wall Insulation Installation
Wall Painting

Plafond
Gypsum Plafond Installation
Plafond Insulation Work
Plafond Painting Work

Roof and Canopy


Roof Frame Installation
Roof Material Installation

Frames, Doors and Windows


Window and Door Frames Installation (with accessories)
Doors Installation (with accessories)
Windows + Glass Installation (with accessories)
Finishing Work for Doors

Floors
Sitting area Floor
Terrace are Floor
Bed Room and Living Room Floors
Bath Room Floor and Wall

e). Mechanical, andElectrical


 Clean Water Installation WorkRated
voltage : 6.3/12 kV
 Waste ans Used Water Installation
WorkLightning impulse withstand voltage :
75kV

Page 7 of 14
 Installation of Closet, Sink, Shower and
Faucet.Rated current : 40A
 Procure and Install the Water PumpShort
time withstand current : 25kA
 Water Tower workRated Frequency : 50Hz
 Surge Arrester Rating : 10kA
 Voltage Drop : 3 %
 Outdoor termination Joint Box with IP65
 Altitude for derating factors : 1960 mASL

f). ElectricalMechanical
 Lighting Armature Installation
 Electric Socket and Switch Installation
Electric Panel Installation.

c). Open field in an area of 8,610 m2 with the
following detail:
 Football field: 4,050 m2
 Track area: 2,280 m2
 Track & Field area: 2,280 m2

d). Tribune and its supporting building in an area


of 1,200 m2 with the following detail:
 1st floor: 800 m2
(tribune for audience, public toilet, 2 dressing rooms,
referee room, match committee room, clinic and storage room)
2nd floor: 400 m2
(tribune for audience + VIP, office, storage room, committee room, service room and
prayer room (mushola)

Sports Venue

Page 8 of 14
Closed field (for futsal, basket ball, Badminton, volley ball, function room): 1000 m 2

Detail Activities included in the design work are as follow:


Soccer field civil work design + track-and-field area
Architectural, building, landscape design
Structural design which meet standard includes:
Structural calculations of applicable loading standards
include the calculation of Earthquake and Wind loads at the
project site.
Calculation of Slope and Slope Stability based on
geotechnical analysis and soil data on the building site and
its landscape.
Planning of Peeling and Land Acquisition and placement of
excess land (disposal.
Calculation of Road Access Planning and Pavement Road

Mechanical and electrical design which meet standard


includes:
Clean Water Piping System Design
Waste Water Piping System Design
Fire Protection System Design
Other Utility Design required to meet safety and
environmental standards in planning
Topographic data collection and soil structure tests,
including Bore Holes Soil investigation, Soil Core sampling,
SPT test, CPT / Machintose Test, Test pit, Lab testing and
other data.
Interior planning attached to the building
Standard lighting design
Sound Planning (public address system)

Deliverables / Final Product:


Scope of Work Attachment (to be used as an attachment in the
process of selection of other provider for construction of
Building and Sports Center in Muara Laboh)
Perspective drawing
Factual Report for Soil investigation
Color schemes and material data specification
Technical specifications
Construction drawing
Architecture, Structure & ME
Hardscape & Softscape design
Other civil work (Earthwork, Drainage, non-structure, etc)

DESIGN WORK PHASE

Page 9 of 14
Schematic design
Layout + spatial program
Landscape masterplan illustration
Perspective
Survey topography and soil structure test
Design development
Views and Cross-sections
Ceiling and light points design
Pattern design and floor structure material
Mechanical & Electrical
Hardscape & Softscape plan
Drainage
Walking Access and Parking

Construction work documents:


Architectural, Civil Structural & ME drawings
Site planning & utilities drawings
Softscape & Hardscape Drawings
Technical Requirements and Specifications
Color examples and material data
Document of structural and geotechnical calculations for
earthwork and foundation Work and building structures
Bill of Quantity (BoQ)
Estimated construction cost
Technical evaluation on bidding process of construction
works
Supervision of construction works including review of As-
Built Drawing provided by construction provider.

III. DESIGN & BUILD WORK SCHEDULE


The services as described above shall be completed
within 20 14 (sixteenfourteen) weeks days after
Proposal of Schematic Design approved and XX4 months
for transporting the containercomplete material and
modification worksupon ITP (Instruction to Perform)
issuance. While the construction supervision work
shall be performed during the Sports Center
construction work is performed by another construction
provider with an estimated duration of 18 months.

Page 10 of 14
IV. PERSONNEL QUALIFICATION
Contractor shall provide a team consisting of at least
:
i. Team leader, having expertise in design and
supervisiosupervision of n of building/camp
acommodation and sports center construction
ii. Civil, and ArchitecturalMechanical & Electrical
Engineering Designer for Building and Sports
Centercamp accommodation Structuresproject
iii. Landscape and Utility Engineering Designer for
Buildings and Sports Center Structure
iv. Technical Supervisor for construction of
building/Camp accommodationproject and sports
center

The team leader shall coordinate all the activities


and responsibilities related to the provision and
performance of services.

V. CONTRACTOR’S RESPONSIBILITIES
a. Contractor shall be responsible to make sure that
all the personnel are in good health condition.
Contractor shall submit to the Company a valid
result of medical check-up (conducted within one
year).
b. Contractor shall be responsible to provide
technical drawings including the required copies
during the work execution.

Page 11 of 14
c. Contractor shall be responsible to accompany
building construction bidders during the tender
process for a maximum of five (5) times visit. If
additional site visit is required, the Company
will be responsible for the costs incurred which
costs shall be previously approved by the
Company.
d. Ensure planning results are technically
accountable.
e. Provide standard personal protective equipment
while working at the project site.

VI. COMPANY’S RESPONSIBILITIES


a. With approval and direction from Company, Company
will be responsible for the accommodation at
Muara Laboh, transportation from Jakarta to Muara
Laboh, but excluding personnel who perform Survey
Topography and Land Investigation work.
b. Company to provide safety induction to
Contractor’s personnel working at the project
site.
c. As long as it is available and can be provided,
Company will provide data and information
required by Contractor for the work execution
d. Company shall provide access to Contractor’s
personnel during the site visit.

VII. COMPANY AND CONTRACTOR RESPONSIBILITY


During the work execution, all formal communication
shall be made in writing to the relevant persons as
listed below.

Page 12 of 14
COMPANY:
PT. Supreme Energy Muara LabohRantau Dedap
Menara Sentraya, 23rd Floor
Jl. Iskandarsyah Raya No. 1A
Kebayoran Baru, Jakarta 12160
Phone: +62-21-27882222 (Hunting)
Fax: +62-21-27882333

Company’s Representative (Contract’s holder):


Ralph HoellmannErwin Patrisa Floris, Head of Community
Relations & AffairProject Manager
Email: erwin-patrisa@supreme-energy.comralph-
hoellmann@supreme-energy.com

Below are additional contact persons for specific


matters.

For technical matters:


1. Ismoyo ArgoFranky Tungka, Sr. Site Support Manager
Business Relations
Email: ismoyo-argo@supreme-energy.comfranky-
tungka@supreme-energy.com
2. Ridha Mulia, Site Manager
Email: ridha-mulia@supreme-energy.com
3. Fadlis Barnaji, Project Controller
Email: fadlis-barnaji@supreme-energy.com

For contractual matters:

Page 13 of 14
1. Faishal Dwi Ismail
Email: faishal-dwi@supreme-energy.com
2. Hary Wibowo, Sr. Manager SCM
Email: hary-wibowo@supreme-energy.com

For invoicing matters:


1. Ketut Murniata, Accounts Payable
Email: ketut-murniata@supreme-energy.com

CONTRACTOR:

PT. Garis PradaKAIOO Design & Build


Talavera Office Park 28th Floor
Jl. Pondok Betung Raya, No. 89, Pondok Aren,
TangerangT.B. Simatupang Kav. 22-26, Jakarta Selatan -
152252430
Phone: +62 21 736900785997940, Fax: +62 21
736910595999888

Contractor’s Representative:
Oke S. Suharyono (Managing Director)Arfan
Email: officke.kaioo@garispradamail.com
Phone: +62 8186 0981858 2696669xxx

Page 14 of 14