Table D-1 Specified Minimum Yield Strength for Steel Pipe Commonly Used
in Piping Systems
Type
Spec. No. Grade [Note (1)] SMYS, psi (MPa)
--`,,```,,,,````-`-`,,`,,`,`,,`---
1
See para. 841.1.
128
Copyright ASME International
Provided by IHS under license with ASME
No reproduction or networking permitted without license from IHS Not for Resale
ASME B31.8-2010
Table D-1 Specified Minimum Yield Strength for Steel Pipe Commonly Used
in Piping Systems (Cont’d)
Type
Spec. No. Grade [Note (1)] SMYS, psi (MPa)
GENERAL NOTE: This table is not complete. For the minimum specified yield strength of other grades
and grades in other approved specifications, refer to the particular specification.
NOTES:
(1) Abbreviations: BW p furnace buttwelded; DSA p double submerged-arc welded; EFW p electric
fusion welded; ERW p electric resistance welded; FW p flash welded; S p seamless; LW p laser
welded.
(2) Intermediate grades are available in API 5L.
(3) See applicable plate specification for SMYS.
--`,,```,,,,````-`-`,,`,,`,`,,`---
Long-Term Hydrostatic Strength Values for Thermoplastic Pipes Covered by ASTM D 2513. The val-
ues apply only to materials and pipes meeting all the requirements of the basic materials and
ASTM D 2513. They are based on engineering test data obtained in accordance with ASTM D 1599 and
analyzed in accordance with ASTM D 2837. A list of commercial compounds meeting these require-
ments is published yearly by the Plastics Pipe Institute.
Long-Term Hydrostatic Strength for Reinforced Thermosetting Pipes Covered by ASTM D 2517 is
11,000 psi (75.8 MPa). The values apply only to materials and pipes meeting all the requirements of
the basic materials and ASTM D 2517. They are based on engineering test data obtained in accor-
dance with ASTM D 1599 and analyzed in accordance with ASTM D 2837.