Space-Saving Installation: Fieldbus System

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

Fieldbus System

* O nly the SY and SV valves


are UL-compliant.
(Output device for driving 5-port solenoid valves)
RoHS

Space-saving ¡IO-Link compatible

installation
¡IP67
* F
 or units with a D-sub connector,
and when connected to S0700 manifolds, it is IP40.

Compact ¡Drives up to 32 solenoids


Approx.
¡Daisy-chain wiring
28 mm Actual size
communication
* Excludes the units compatible with IO-Link

<Compatible Protocols>

Made to Order
Please contact SMC for details on compatible products.

A functional safety standard compliant


product has been added.
(PROFIsafe compatible)
¡Product certification obtained by a third party
(IEC 61508/62061 SIL 3, ISO 13849 PL e Cat. 3)
¡Safety output for valve control

EX260 Series
CAT.E02-25D
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

Manifold length reduced by approx. 53 mm


Approx. 28 mm M12 communication
connector x 2
M12 communication
connector x 1
D-sub communication
connector
Approx. 53 mm (For daisy-chain wiring) (Same for the solenoid valve power supply wiring)

Existing
model
EX250
Approx.
77 mm

Approx.
81 mm 103 mm Approx.
28 mm

Daisy-chain wiring communication is possible.∗1


A branch connector is not necessary/Reduced wiring space
∗1 Excludes the units compatible with IO-Link
A branch connector
is not necessary. Existing model (EX250)
EX260

Daisy-chain
wiring

Daisy-chain
wiring

Reduced
wiring space

Wiring and piping from the An external terminating resistor is not necessary.
same direction is possible. (Only available for M12 PROFIBUS DP, CC-Link communication connectors)

(for side ported) ON/OFF switching is possible with an internal terminating resistor.
An external terminating resistor is not necessary.
External terminating
When there is resistor
limited space above
the valve

BUS OUT

1 P 1 P

BUS IN

3/5 E 2 B2 B2 B2 B2 B 3/5 E

PWR
4 A4 A4 A4 A4 A

Internal
terminating
resistor

BUS OUT

1 P 1 P

BUS IN

3/5 E 2 B2 B2 B2 B2 B 3/5 E

PWR
4 A4 A4 A4 A4 A

SI unit Fieldbus
1
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

Product Specification Variations

16
Number of
outputs
32

PNP
Output
polarity
NPN

M12
Communication
connector
D-sub

Applicable Valve Series and Compatible Protocols


Fieldbusses &
Industrial Ethernet

Flow rate characteristics


(4/2 / 5/3) Max. number Power consumption Applicable
Series
of solenoids [W] cylinder size
C [dm /(s·bar)]
3
b

IP67 *
1
SY3000 1.6 0.19 ø50
0.35 (Standard)
®
SY5000 3.6 0.17 32 0.1 (With power- ø63
saving circuit)
SY7000 5.9 0.20 ø80
IP40 *1, *2
IP67 JSY1000 0.91 0.48 0.2 (With power-saving circuit) ø40
IP67
JSY3000 2.77 0.27 32 0.4 (Standard) ø50
0.1 (With power-
JSY5000 6.59 0.22 saving circuit) ø80
IP67
IP40
IP40 S0700 *3 0.37 0.39 32 0.35 ø25

IP67 *1 SV1000*3 1.1 0.35 ø40

SV2000*3 2.4 0.18 32 0.6 ø63


IP67
®

IP67
SV3000*3 4.3 0.21 ø80
IP40
IP67 *
IP67 1 VQC1000 1.0 0.30 ø40
0.4 (Standard)
VQC2000 3.2 0.30 ø63
24
VQC4000 7.3 0.38 0.95 (Standard) ø160
IP67
IP40
IP67 VQC5000 17 0.31 0.4 (Low-wattage type) ø180
IP67

Safety The use of validated products may be required for valve manifolds used in the safety-related parts of equipment which is
Communication
IP67 compliant with safety standard ISO 13849. For validated products, please contact your SMC sales representative.

Flow rate characteristics


IP67 (4/2 / 5/3) Max. number Power consumption Applicable
Series
of solenoids [W] cylinder size
C [dm /(s·bar)]
3
b

IP67 SY3000 1.6 0.19 ø50


0.35 (Standard)
IP67 ®
SY5000 3.6 0.17 32 0.1 (With power- ø63
saving circuit)
SY7000 5.9 0.20 ø80
IP40 *2
IP67 JSY1000 0.91 0.48 0.2 (With power-saving circuit) ø40

JSY3000 2.77 0.27 32 0.4 (Standard) ø50


0.1 (With power-
JSY5000 6.59 0.22 saving circuit) ø80
IP67
IP40 VQC1000 1.0 0.30 ø40
IP67
0.4 (Standard)
VQC2000 3.2 0.30 ø63
24
VQC4000 7.3 0.38 0.95 (Standard) ø160
IP67
IP40 0.4 (Low-wattage type)
VQC5000 17 0.31 ø180

*1IP67
Units with a D-sub communication connector are IP40.
*2 The JSY1000 is IP40.
*3IP67
There is no manifold part number setting for the IO-Link compatible SI units.

IP67
2
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

IO-Link compatible
Integratable with various existing networks
IO-Link devices can be easily connected to various networks via the IO-Link master, which acts as a gateway between IO-Link
communication and various Fieldbusses.
Solenoid valves can be connected for communication without relying upon a Fieldbus or PLC.
Fieldbus
IO-Link communication

IO-Link master
(Commercially available)

Can be connected using a single general-purpose cable,


resulting in a reduction in the space required for wiring
Port class B • Connect the IO-Link master port to the device using a 1:1 configuration.
IO-Link master • Connect using an M12 round connector.
(Commercially available) • Maximum cable length: 20 m
Power
supply
• Special communication cables are not necessary.
load • In order to connect the SI unit using a single cable,
use a port class B type IO-Link master. Port class B compliant

General-purpose 5-wire unshielded cables are used


for connection. SI unit/Connector pin arrangement
Port class A The signal wire and valve power supply wire can be
connected with the same cable. Pin SI unit port pin function
IO-Link master no. (Port class B)
(Commercially available)
1 +24 V for control unit
2 +24 V for solenoid valve
3 0 V for control unit
4 IO-Link communication
5 0 V for solenoid valve

Power
supply
load
Y Branch Connector
Difference between IO-Link
master port class A and class B Port class A compliant
Pin IO-Link master port pin function A special wiring Y branch 1
no. Port class A Port class B connector is available. Connect to
2
3
1 +24 V +24 V the master 4 1
Additional power 5 2
2 NC/DI/DO Connect to
3
supply +24 V the SI unit
4
3 0V 0V 5
1
4 IO-Link/DI/DO IO-Link/DI/DO
2
Additional power Connect to
3
5 NC Used when connecting to a port power supply 4
supply 0 V
class A type IO-Link master, which is 5
often used when connecting to an
IO-Link sensor

3
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

IO-Link compatible
Features an impressive self-diagnosis function Self-diagnosis contents
Diagnostic contents Event category
Internal failure of the SI unit Error
Output short circuit Error
Output open circuit Error
Solenoid valve power supply failure Warning
Abnormal internal temperature
Warning
of the SI unit
Fieldbus Output switching count value
Notification
exceeded
Process data Service data

Real-time diagnosis Request base diagnosis


(Process data) (Service data)
· Any event information detect- · Regarding detailed diagnos-
ed by the SI unit using the tic information, the event
process data as the diagnos- codes can be transmitted as
tic input can be transmitted to service data to the PLC and
the PLC and PC in real time PC.
via the master Fieldbus.
IO-Link master
· 3 types of event flags are (Commercially
transmitted to the PLC. (Er- available)
ror/Warning/Notification)

Equipped with a solenoid valve output operation count function


The number of valve operation instructions is counted for each output of the solenoid
valve.
Set the count threshold value to be used as a guide for maintenance according to the operating conditions of the
cylinder connected to the solenoid valve.
d
Once the threshold value is reached, notification of this fact will take place automatically.
d
This enables periodic maintenance to be performed before any unexpected cylinder failures occur.

IO-Link master
(Commercially available)

Currently
Notification of the at 5 million
fact that the count Currently
operations
threshold has been at 10 million
exceeded operations

4
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

Supports safety communication (PROFIsafe) <EX260-FPS1>


PROFIsafe is established as an international standard (IEC 61784-3-3). It is a communication
protocol that transmits safety-related data by PROFINET communication and can be used up
until safety standards ISO 13849-1 PL e and IEC 61508/IEC 62061 SIL 3.

PROFINET/PROFIsafe
compatible PLC

PROFINET/PROFIsafe
A PROFIsafe compatible
PROFIsafe PROFINET PLC allows for the use of a
P RO F I N E T c o m p a t i bl e
SI unit and a PROFIsafe
compatible SI unit to be
used on one communication
line at the same time.

EX260-FPS1 EX260-SPNm
(PROFIsafe compatible SI unit) (PROFINET compatible SI unit)

Compliant with safety standards


This product (EX260-FPS1) is intended to facilitate safe machine and system designing (ISO/IEC standard compliance)
and has been certified by a third party (TÜV Rheinland) for use up until the standards listed below.
· SIL (Safety Integrity Level)
A safety integrity level as defined by international standard IEC 61508/62061
There are 4 levels of safety, with the lowest being SIL 1 and the highest being SIL 4.
· PL (Performance Level)
A scale used to define the capability of safety-related parts to perform a safety function as defined by
IEC 61508/IEC 62061 SIL 3 international standard ISO 13849
There are 5 levels of safety function, with the lowest being PL a and the highest being PL e.
ISO 13849 PL e/Cat. 3

Safety Output
This product (EX260-FPS1)
has a safety switch inside the Valve
Communication
Internal control unit PROFINET interface
product. It shuts off the voltage RD+
connector 1
supplied to the valve by TD+
Non-safety OUT0
turning OFF the safety switch RD−
control unit OUT1
via directive from the PLC to TD− · ·
enter safe state. The safety
· ·
switch of this product (EX260- Communication RD+ 32 valve · ·
FPS1) has two redundancies, connector 2 outputs
TD+ · ·
one on the 24 V side and the Safety control unit
RD− · ·
other on the 0 V side. It
TD− OUT30
continuously runs diagnostics.
OUT31
The safety switch is turned
OFF in the event of an error DC-DC
Power 24 V PWR
detection. connector Safety switch
0 V PWR
24 V PWR (V)
0 V PWR (V) COM

Safety output unit


PROFIsafe

Safety Definition
The safe state of this product (EX260-FPS1) is a condition in which the safety output described above is turned OFF to shut off the supply of power
to the valve manifold.
This product does not cover valve manifolds that are being used in connection with this product or the safety function and safe state of electric/air
equipment that includes a peripheral circuit.

5
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series

Reduced wiring, Space saving


For built-in safety output (EX260-FPS1)

¡A separate safety output unit is not required. (Space saving)


¡There is no need for wiring between the safety output unit and the EX260-FPS1. (Reduced wiring)

For PROFINET/PROFIsafe

PROFINET/PROFIsafe

EX260-FPS1 EX260-FPS1

Built-in safety output


For control: 0 V/24 V PWR

For driving: 0 V/24 V PWR (V)


Power supply Power supply
for control for driving

When a separate safety output unit is installed (Conventional connection example)


¡A separate safety output unit is required. (Increased installation space)
¡Increased wiring is required for connection with another unit. (Increased wiring)

For PROFINET/PROFIsafe

PROFIsafe PROFINET

Safety output unit


(Commercially available)

Safety output
(Power supply for valve) EX260-SPN EX260-SPN

Power supply Power supply


for control for driving

Safety of the machine or system


The manufacturer of the machine/system and its user are responsible for the safety of the machine/system. Use of this product (EX260-FPS1)
requires machine/system safety concepts which are in accordance with the corresponding directives and standards, safety function validation, and
hazard and risk analysis. Target SILs (IEC 61508/62061 compliance) and performance levels/categories (ISO 13849 compliance) are determined
based on the risk analysis. For more information, refer to the “Safety of the machine or system” section in the operation manual of the EX260-FPS1.

6
CONTENTS
Fieldbus System How to Order SI Units  p. 9
(Output device for driving 5-port solenoid valves) Specifications  p. 10
Dimensions  p. 12
EX260 Series Parts Description  p. 13
LED Indicator  p. 14

Accessories
q Communication Cable  p. 15
w Field-wireable Communication Connector  p. 21
e Power Supply Cable (For SI unit)  p. 22
r Power Supply Cable (For SI unit/For power block)  p. 23
t Seal Cap (10 pcs.)  p. 23
y Output Block  p. 24
u Power Block  p. 24
i Connector for Output Block Wiring  p. 25
o End Plate  p. 25
!0 Bracket Plate/DIN Rail Mounting Bracket  p. 25

Made to Order
SI Unit
EtherNet/IP™ Web server function compatible  p. 26
Communication Cable  p. 26
Power Supply Cable  p. 27

Specific Product Precautions  p. 28

7
Fieldbus System
For Output

EX260 Series * Only the SY and SV valves


are UL-compliant.

Compact design Compact design for space saving

32/16 digital output type available for each unit in the series
Number of outputs (IO-Link and PROFIsafe are only compatible with the 32-point digital output type.)

Negative common (PNP)/positive common (NPN) type available for each unit in the series
Output polarity (Only negative common (PNP) is available for Ethernet POWERLINK, IO-Link, and PROFIsafe.)

Enclosure IP67 (For units with a D-sub connector, and when connected with S0700 manifolds, it is IP40.)

ON/OFF switching is possible with an internal terminating resistor for communication.


Internal terminating resistor (Only for units compatible with M12 PROFIBUS DP, CC-Link communication connectors)

Applicable Manifold
SY3000/5000/7000 JSY1000/3000/5000

VQC1000/2000/4000/5000

S0700 SV1000/2000/3000

D D D
D D D
D D D
D D D

8
EX260 Series

How to Order SI Units

EX260 S PR1
Communication protocol
Symbol Protocol Number of outputs Output polarity Communication connector Manifold symbol Applicable manifold
DN1 Source/PNP (Negative common) QAN
32
DN2 Sink/NPN (Positive common) QA
DeviceNet™ M12
DN3 Source/PNP (Negative common) QBN
16
DN4 Sink/NPN (Positive common) QB
PR1 Source/PNP (Negative common) NAN
32
PR2 Sink/NPN (Positive common) NA
M12
PR3 Source/PNP (Negative common) NBN
16
PR4 Sink/NPN (Positive common) NB
PROFIBUS DP
PR5 Source/PNP (Negative common) NCN
32
PR6 Sink/NPN (Positive common) NC
D-sub∗1
PR7 Source/PNP (Negative common) NDN
16
PR8 Sink/NPN (Positive common) ND
MJ1 Source/PNP (Negative common) VAN
32
MJ2 Sink/NPN (Positive common) VA SY3000/5000/7000
CC-Link M12 JSY1000/3000/5000
MJ3 Source/PNP (Negative common) VBN
16 VQC1000/2000/4000/5000
MJ4 Sink/NPN (Positive common) VB S0700
EC1 Source/PNP (Negative common) DAN SV1000/2000/3000
32
EC2 Sink/NPN (Positive common) DA
EtherCAT M12
EC3 Source/PNP (Negative common) DBN
16
EC4 Sink/NPN (Positive common) DB
PN1 Source/PNP (Negative common) FAN
32
PN2 Sink/NPN (Positive common) FA
PROFINET M12
PN3 Source/PNP (Negative common) FBN
16
PN4 Sink/NPN (Positive common) FB
EN1 Source/PNP (Negative common) EAN
32
EN2 Sink/NPN (Positive common) EA
EtherNet/IP™ M12
EN3 Source/PNP (Negative common) EBN
16
EN4 Sink/NPN (Positive common) EB
PL1 Ethernet 32 GAN
Source/PNP (Negative common) M12
PL3 POWERLINK 16 GBN
SY3000/5000/7000
IL1 IO-Link 32 Source/PNP (Negative common) M12 KAN JSY1000/3000/5000
VQC1000/2000/4000/5000
∗1 Enclosure is IP40 when the communication connector is D-sub.

Madeeto Made to Order


Ord r
a p. 26
EtherNet/IPTM Web server function compatible

∗ For “How to Order Manifold Assembly,” refer to the Web Catalog of each valve.

Safety communication compliant SI unit

EX260 F PS1
Communication protocol
Symbol Protocol Number of outputs Output polarity Communication connector Manifold symbol Applicable manifold
SY3000/5000/7000
PS1 PROFIsafe 32 Source/PNP (Negative common) M12 FPN JSY1000/3000/5000
VQC1000/2000/4000/5000

* T
 he use of validated products may be required for valve manifolds used in the safety-related parts of equipment which is compliant with safety standard
ISO 13849. For validated products, please contact your SMC sales representative.
9
Fieldbus System
For Output EX260 Series

Specifications
All SI Units Common Specifications
Power supply Power supply voltage 21.6 to 26.4 VDC*1
for control Internal current consumption 100 mA or less*4
Power supply for output Power supply voltage 22.8 to 26.4 VDC
Enclosure IP67*2
Operating temperature range −10 to +50°C
Environmental
Operating humidity range 35 to 85% RH (No condensation)
resistance
Withstand voltage 500 VAC for 1 minute between terminals and housing
Insulation resistance 10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Standards CE marking (EMC directive/RoHS directive), UL (CSA) compliant
Weight 200 g
Mounting screw 2 pcs.
Accessories Seal cap
EX9-AWTS (1 pc.)*3
(for M12 connector socket)
*1 T
 o serve as the power supply for communication, the power supply voltages are 11 to 25 VDC for the EX260-SDNm, 18 to 30 VDC for the EX260-SIL1,
and 20.4 to 28.8 VDC for the EX260-FPS1.
*2 IP40 applies to EX260-SPR5/6/7/8.
*3 Not provided for EX260-SPR5/6/7/8
*4 200 mA or less for the EX260-FPS1

Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4


Protocol PROFIBUS DP DeviceNet™
Applicable Volume 1 (Edition 3.5)
Version*1 DP-V0
system Volume 3 (Edition 1.5)
Configuration file*3 GSD file EDS file
I/O occupation area SPR1: 0/32 SPR2: 0/32 SPR5: 0/32 SPR6: 0/32 SDN1: 0/32 SDN2: 0/32
(Inputs/Outputs) SPR3: 0/16 SPR4: 0/16 SPR7: 0/16 SPR8: 0/16 SDN3: 0/16 SDN4: 0/16
Applicable function — QuickConnect™
Communication speed 9.6 k/19.2 k/45.45 k/93.75 k/187.5 k/500 k/1.5 M/3 M/6 M/12 Mbps 125 k/250 k/500 kbps
Communication connector specification M12 D-sub*4 M12
Terminating resistor switch Built-in None
Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN
Output type
(Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common)
Number of SPR1: 32 points SPR2: 32 points SPR5: 32 points SPR6: 32 points SDN1: 32 points SDN2: 32 points
outputs SPR3: 16 points SPR4: 16 points SPR7: 16 points SPR8: 16 points SDN3: 16 points SDN4: 16 points
Output
Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
Supplied voltage 24 VDC
Supplied SPR1: Max. 2.0 A SPR2: Max. 2.0 A SPR5: Max. 2.0 A SPR6: Max. 2.0 A SDN1: Max. 2.0 A SDN2: Max. 2.0 A
current SPR3: Max. 1.0 A SPR4: Max. 1.0 A SPR7: Max. 1.0 A SPR8: Max. 1.0 A SDN3: Max. 1.0 A SDN4: Max. 1.0 A

Model EX260-SMJ1/3 EX260-SMJ2/4 EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4


Protocol CC-Link EtherCAT*2 PROFINET*2
Applicable Conformance PROFINET Specification
Version*1 Ver. 1.10
system Test Record V.1.1 Version 2.2
Configuration file*3 CSP+ file XML file GSD file
SMJ1: 32/32 SMJ2: 32/32
I/O occupation area SEC1: 0/32 SEC2: 0/32 SPN1: 0/32 SPN2: 0/32
SMJ3: 32/32 SMJ4: 32/32
(Inputs/Outputs) SEC3: 0/16 SEC4: 0/16 SPN3: 0/16 SPN4: 0/16
(1 station, remote I/O stations) (1 station, remote I/O stations)
Applicable function — FSU, MRP
Communication speed 156 k/625 k/2.5 M/5 M/10 Mbps 100 Mbps*2
Communication connector specification M12
Terminating resistor switch Built-in None (Not required)
Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN
Output type
(Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common)
Number of SMJ1: 32 points SMJ2: 32 points SEC1: 32 points SEC2: 32 points SPN1: 32 points SPN2: 32 points
outputs SMJ3: 16 points SMJ4: 16 points SEC3: 16 points SEC4: 16 points SPN3: 16 points SPN4: 16 points
Output Solenoid valve with surge voltage
Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC)
suppressor 24 VDC, 1.0 W or less (SMC)
Supplied voltage 24 VDC
Supplied SMJ1: Max. 2.0 A SMJ2: Max. 2.0 A SEC1: Max. 2.0 A SEC2: Max. 2.0 A SPN1: Max. 2.0 A SPN2: Max. 2.0 A
current SMJ3: Max. 1.0 A SMJ4: Max. 1.0 A SEC3: Max. 1.0 A SEC4: Max. 1.0 A SPN3: Max. 1.0 A SPN4: Max. 1.0 A
*1 Please note that the version is subject to change.
*2 Use a CAT5 or higher communication cable for EtherCAT, PROFINET, Ethernet/IP™, and Ethernet POWERLINK.
*3 The configuration file can be downloaded from the SMC website: https://www.smcworld.com
∗4 Enclosure is IP40 when the communication connector is D-sub.
10
EX260 Series

Specifications
Model EX260-SEN1/3 EX260-SEN2/4 EX260-SPL1 EX260-SPL3 EX260-SIL1 EX260-FPS1
PROFINET/
Protocol EtherNet/IP™*2 Ethernet POWERLINK IO-Link
PROFIsafe*2

PROFINET Specification
Applicable
Volume 1 (Edition 3.17) EPSG DS 301 Version 2.3
system Version*1 V1.1
Volume 2 (Edition 1.18) Version 1.2.0 PROFIsafe Specification
Version 2.4
Configuration file*3 EDS file XDD file IODD file GSD file
I/O occupation area SEN1: 16/32 SEN2: 16/32 0/32
16/32 16/16 0/32*5
(Inputs/Outputs) SEN3: 16/16 SEN4: 16/16 16/32*4
FSU, Shared Device,
Applicable function QuickConnect™, DLR — —
MRP
Communication speed 10 M/100 Mbps*2 100 Mbps*2 COM3/COM2*4 100 Mbps*2
Communication connector specification M12
Terminating resistor switch None (Not required)
Source/PNP Sink/NPN Source/PNP
Output type
(Negative common) (Positive common) (Negative common)
Number of SEN1: 32 points SEN2: 32 points
32 16 32
outputs SEN3: 16 points SEN4: 16 points

Solenoid valve with


Output Solenoid valve with surge voltage surge voltage
Load
suppressor 24 VDC, 1.5 W or less (SMC) suppressor 24 VDC,
0.95 W or less (SMC)
Supplied voltage 24 VDC
Supplied SEN1: Max. 2.0 A SEN2: Max. 2.0 A
Max. 2 A Max. 1 A Max. 2 A Max. 1.3 A
current SEN3: Max. 1.0 A SEN4: Max. 1.0 A
*1 Please note that the version is subject to change.
*2 Use a CAT5 or higher communication cable for PROFINET, PROFIsafe, Ethernet/IP™, and Ethernet POWERLINK.
*3 The configuration file can be downloaded from the SMC website: https://www.smcworld.com
*4 A selection can be made using the setting switch.
*5 In addition, it occupies input 4 bite/output 5 bite for safety.

11
Fieldbus System
For Output EX260 Series

Dimensions
M12 communication connector type D-sub communication connector type
(EX260-SPR5/6/7/8)
For PROFIBUS DP For DeviceNet™
For PROFIBUS DP
For CC-Link For EtherCAT For PROFINET
For EtherNet/IP™ For Ethernet POWERLINK
90.9

90.9

90.9

90.9
102.4

102.4
102.4

102.4

28.2 28.2 21 21
20.6 20.6
16.4 9
16.4 9 28.2 28.2 28.75 28.7529.25 29.25
9 9
76.5 76.5 76.5 76.5

M12 communication connector type M12 communication connector type


For IO-Link For PROFIsafe
90.9

90.9
102.4

102.4

28.2 20.6 25.4 28.2 21 20.6 16.4 9


76.5 78

12
EX260 Series

Parts Description
For PROFIBUS DP For DeviceNet™ For CC-Link Cover screw (M2.5)

For PROFIsafe For EtherCAT For PROFINET


For EtherNet/IP™ For Ethernet POWERLINK Cover

Setting switch
Position indicator LED

Output connector
* The
 setting switch varies depending on the model.
Refer to the operation manual for details.
It can be downloaded via the SMC website: https://www.smcworld.com

<Connector> M12 communication connector type


EX260-SECl
EX260-SPNl
EX260-SPR1/-SPR2
Part no. EX260-SDNl EX260-SMJl EX260-SENl
-SPR3/-SPR4 EX260-SPLl
EX260-FPS1
EtherCAT
PROFINET
Communication protocol PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™
EtherNet POWERLINK
PROFIsafe
Communication connector (M12) 5 pins, socket, 5 pins, socket, 5 pins, socket, 4 pins, socket,
BUS OUT B code (SPEEDCON) A code (SPEEDCON) A code*1 (SPEEDCON) D code (SPEEDCON)
Communication connector (M12) 5 pins, plug, 5 pins, plug, 4 pins, plug, 4 pins, socket,
BUS IN B code (SPEEDCON) A code (SPEEDCON) A code (SPEEDCON) D code (SPEEDCON)
Ground terminal M3
5 pins, plug, 4 pins, plug, 5 pins, plug, 5 pins*2, 4 pins*3,
Power connector (M12)
A code (SPEEDCON) A code (SPEEDCON) B code (SPEEDCON) plug, A code (SPEEDCON)
*1 R ecommended mating M12
4-pin plug part no.:
<Connector> D-sub communication connector type PCA-1567717
*2 For EtherCAT, PROFINET,
Part no. EX260-SPR5/-SPR6/-SPR7/-SPR8
and Ethernet POWERLINK
Communication protocol PROFIBUS DP *3 For EtherNet/IP™ and
Ground terminal M3 PROFIsafe
Communication connector (D-sub) BUS IN/OUT 9 pins, socket
Power connector (M12) 5 pins, plug, A code

For IO-Link Cover screw (M2.5)

<Connector>
Part no. EX260-SIL1
Cover Communication protocol IO-Link
Setting switch Communication/ 5 pins, plug,*1
Position indicator LED Power connector (M12) A code (SPEEDCON)
Ground terminal M3
*1 T
 he communication line, SI unit power supply line, and the
solenoid valve power supply line are connected using the
Output connector same cable.

* T
 he setting switch varies depending on the model.
Refer to the operation manual for details.
It can be downloaded via the SMC website: https://www.smcworld.com
13
Fieldbus System
For Output EX260 Series

LED Indicator

For DeviceNet™ EX260-SDNm For EtherCAT EX260-SECm


PWR (V):
NS: Network state Power supply for solenoid valve L/A IN: BUS IN state L/A OUT: BUS OUT state

MS: SI unit state PWR: Power supply for control RUN: PWR: PWR (V):
Operation state Power supply for control Power supply for solenoid valve

For EtherNet/IP™ EX260-SENm For CC-Link EX260-SMJm


L/A1: BUS IN state L/A2: BUS OUT state L ERR: Communication error PWR: Power supply for control

PWR (V): PWR (V):


NS: Network state Power supply for solenoid valve L RUN: Communication state Power supply for solenoid valve
MS: SI unit state

For PROFINET EX260-SPNm For PROFIBUS DP EX260-SPRm


PWR (V):
L/A 1: BUS IN state L/A 2: BUS OUT state SF: System fault Power supply for solenoid valve

PWR (V): BF: Bus fault PWR: Power supply for control
SF: SI unit diagnosis Power supply for solenoid valve
BF: Communication state PWR: Power supply for control

For Ethernet POWERLINK EX260-SPLm For IO-Link EX260-SIL1


L/A 1: BUS IN state L/A 2: BUS OUT state

PWR (V): PWR (V):


S/E: Network state Power supply for solenoid valve COM: Network state Power supply for solenoid valve
ST: SI unit state

For PROFIsafe EX260-FPS1


L/A1: BUS IN state L/A2: BUS OUT state

PWR (V):
SF: SI unit diagnosis Power supply for solenoid valve
BF: Communication state PWR: Power supply for control

14
EX260 Series
Accessories
q Communication Cable
44.5 5000 50
For CC-Link 22.5
∗1 1 2

ø14.8
PCA-1567720
(Socket) 4 3

ø7.7
Marker tag Marker tag Shield
Socket connector pin arrangement M12
A-coded (Normal key) SPEEDCON
∗1 Number of holes: 5,
47.3 5000 50
Total number of pins: 4
22.5
2 1

ø14.8
PCA-1567717
(Plug) 3 4

ø7.7
Marker tag Marker tag Shield
Plug connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Terminal no. Core wire
Cable O.D. ø7.7 mm
color
1 : SLD
Conductor nominal Data pair 0.5 mm2/AWG20
2 White: DB cross section
3 Yellow: DG Drain 0.34 mm2/AWG22
Made to Order 4 Blue: DA
Wire O.D. (Including insulator) 2.55 mm
Cable length 10000 mm p. 26 Connections Min. bending radius (Fixed) 77 mm

EX9-AC  005  MJ-SSPS (With connector on both sides (Socket/Plug))


44.5 L 47.3
ø14.8

ø14.8
Cable length (L) Metal parts 22.5 Metal parts
005 500 mm
010 1000 mm
020 2000 mm
ø7.7

030 3000 mm M12 Marker tag Marker tag M12


050 5000 mm SPEEDCON SPEEDCON
100 10000 mm
1 2 Terminal Terminal Core wire Signal name 2 1
∗1 no. no. color CC-Link
4 4 Blue DA
2 2 White DB
Item Specifications 3 3 Yellow DG
4 3 1 1 Shield SLD 3 4
Cable O.D. ø7.7 mm
Conductor nominal Data pair 0.5 mm2/AWG20 Metal parts Shield Metal parts Plug connector
Socket connector
cross section Drain 0.34 mm2/AWG22 pin arrangement pin arrangement
Connections
Wire O.D. (Including insulator) 2.55 mm A-coded (Normal key) A-coded (Normal key)
Min. bending radius (Fixed) 77 mm ∗1 Number of holes: 5,
Total number of pins: 4

EX9-AC  005  MJ-SAPA (With angled connector on both sides (Socket/Plug))


35 L 35
33.1 33.1
22.5
Cable length (L)
005 500 mm
29.6
32.5

010 1000 mm
ø7.7

Marker tag Marker tag


020 2000 mm

030 3000 mm ø14.8 Metal parts Metal parts ø14.4


050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON

1 Terminal Terminal Core wire Signal name ∗1 1


no. no. color CC-Link
4 4 Blue DA
2 4 2 2 White DB 4 2
Item Specifications 3 3 Yellow DG
1 1 Shield SLD
Cable O.D. ø7.7 mm 3 3
Conductor nominal Data pair 0.5 mm2/AWG20 Metal parts Shield Metal parts
Plug connector Socket connector
cross section Drain 0.34 mm2/AWG22 pin arrangement
pin arrangement Connections
Wire O.D. (Including insulator) 2.55 mm A-coded (Normal key) A-coded (Normal key)
Min. bending radius (Fixed) 77 mm ∗1 Number of holes: 5,
Total number of pins: 4

15
Accessories EX260 Series

q Communication Cable
44.5 5000 50
For DeviceNet™ 22.5
5 1 2

ø14.8
PCA-1557633
(Socket) 4 3

ø6.7
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) 47.3 5000 50
22.5
5 2 1

ø14.8
PCA-1557646
(Plug) 3 4

ø6.7
Marker tag Marker tag
Plug connector M12
pin arrangement SPEEDCON Item Specifications
A-coded (Normal key)
Cable O.D. ø6.7 mm
Terminal no. Core wire
Conductor nominal Power pair 0.34 mm2/AWG22
color
1 : DRAIN cross section Data pair 0.25 mm2/AWG24
2 Red: V+
3 Black: V- Wire O.D. Power pair 1.4 mm
Made to Order 4
5
White: CAN H
Blue: CAN L
(Including insulator) Data pair 2.05 mm
Cable length 10000 mm p. 26 Connections Min. bending radius (Fixed) 67 mm

EX9-AC  005  DN-SSPS (With connector on both sides (Socket/Plug))


44.5 L 47.3
ø14.8

ø14.8
Cable length (L) Metal parts 22.5 Metal parts
005 500 mm
010 1000 mm
020 2000 mm
ø6.7

030 3000 mm M12 Marker tag Marker tag M12


050 5000 mm SPEEDCON SPEEDCON
100 10000 mm
Terminal Terminal Core wire Signal name
1 2 no. no. 2 1
color DeviceNetTM
Item Specifications 5 1 1 Shield DRAIN 5
Cable O.D. ø6.7 mm 2 2 Red V+
3 3 Black V–
Conductor nominal Power pair 0.34 mm2/AWG22 4 3 4 4 White CAN H 3 4
cross section Data pair 0.25 mm2/AWG24 5 5 Blue CAN L
Wire O.D. Power pair 1.4 mm Socket connector Metal parts Shield Metal parts Plug connector
(Including insulator) Data pair 2.05 mm pin arrangement pin arrangement
Min. bending radius (Fixed) 67 mm A-coded (Normal key) Connections A-coded (Normal key)

EX9-AC  005  DN-SAPA (With angled connector on both sides (Socket/Plug))


36.3 L 36.3
22.5
Cable length (L)
005 500 mm
27.5

010 1000 mm
30

ø6.7

020 2000 mm Marker tag Marker tag


Metal parts
030 3000 mm Metal parts
050 5000 mm ø14.8 M12 M12 ø14.8
100 10000 mm SPEEDCON SPEEDCON

Terminal Terminal Core wire Signal name


1 no. no. 1
5 color DeviceNetTM 5
Item Specifications 1 1 Shield DRAIN
2 4 2 2 Red V+ 4 2
Cable O.D. ø6.7 mm 3 3 Black V–
Conductor nominal Power pair 0.34 mm2/AWG22 4 4 White CAN H
cross section 3 5 5 Blue CAN L 3
Data pair 0.25 mm2/AWG24
Wire O.D. Power pair 1.4 mm Plug connector Metal parts Shield Metal parts
Socket connector
(Including insulator) Data pair 2.05 mm pin arrangement pin arrangement
Min. bending radius (Fixed) 67 mm A-coded (Normal key) Connections A-coded (Normal key)

16
EX260 Series

q Communication Cable
44.5 5000 50
For PROFIBUS DP 22.5
5 1 2

ø14.8
PCA-1557688
(Socket) 4 3

ø7.8
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
47.3 5000 50
22.5
5 2 1

ø14.8
PCA-1557691
(Plug) 3 4

ø7.8
Marker tag Marker tag
Plug connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
Terminal no. Core wire
color Item Specifications
1 :−
2 Green: A Line Cable O.D. ø7.8 mm
3 :−
4 Red: B Line
5 :− Conductor nominal cross section 0.34 mm2/AWG22
Shield line is connected to the knurl. Wire O.D. (Including insulator) 2.55 mm
Connections Min. bending radius (Fixed) 78 mm

For EtherCAT For PROFINET For EtherNet/IP™ For Ethernet POWERLINK For PROFIsafe
EX9-AC  020  EN-PSRJ (Plug/RJ-45 connector)
M12
ø14.8

Cable length (L) Metal parts Metal parts RJ-45


ø6.4

010 1000 mm
020 2000 mm
030 3000 mm 47.3 L 44
050 5000 mm
100 10000 mm Signal name Terminal no. Terminal no. Core wire color 1
2 1 2
TD+ 1 1 White/Orange 3
4
RD+ 2 2 Orange 5
3 3 White/Green 6
3 4 TD− 7
4 4 8
RD− 5
Plug connector Green
Plug connector
Metal parts 6
pin arrangement 7 pin arrangement
D-coded 8

Shield Metal parts


Connections (Straight cable)

Item Specifications
Cable O.D. ø6.4 mm
Conductor nominal cross section 0.14 mm2/AWG26
Wire O.D. (Including insulator) 0.98 mm
Min. bending radius (Fixed) 26 mm

PCA-1446566 (Plug)
ø14.8

47.3 5000 50
2 1

3 4
ø6.5

Plug connector M12


pin arrangement SPEEDCON
Wire guide
D-coded Terminal no. color

1 Yellow: TD+ Item Specifications


2 White: RD+ Cable O.D. ø6.5 mm
3 Orange: TD−
4 Blue: RD− Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Connections Min. bending radius (Fixed) 19.5 mm

17
Accessories EX260 Series

q Communication Cable

For EtherCAT For PROFINET For EtherNet/IP™ For Ethernet POWERLINK


For PROFIsafe

EX9-AC  005  EN-PSPS (With connector on both sides (Plug/Plug))

ø14.8

ø14.8
Cable length (L) 47.3 L 47.3

005 500 mm
010 1000 mm
020 2000 mm

ø6.5
030 3000 mm Metal parts Metal parts
050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON

Terminal Terminal Core wire Signal


2 1 no. no. color name 2 1
1 1 Yellow TD+
2 2 White RD+
3 4 3 3 Orange TD− 3 4
Blue RD−
4 4
Plug connector Plug connector
pin arrangement Metal parts Shield Metal parts pin arrangement
D-coded D-coded
Connections (Straight cable)

Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm

EX9-AC  005  EN-PAPA (With angled connector on both sides (Plug/Plug))


36.3 L
Cable length (L)
005 500 mm
010 1000 mm
30.8

ø6.5

020 2000 mm Metal


parts Metal parts
030 3000 mm
050 5000 mm M12 M12
100 10000 mm ø15 SPEEDCON SPEEDCON

Terminal Terminal Core wire Signal


1 no. no. 3
color name
1 1 Yellow TD+ 2
2 4 White RD+
4
2 2
3 3 Orange TD−
3 4 4
Blue RD− 1
Plug connector Metal parts Shield Metal parts Plug connector
pin arrangement pin arrangement
D-coded Connections (Straight cable) D-coded

Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm

18
EX260 Series

q Communication Cable

For IO-Link Power


supply load
Port class B
IO-Link master (Commercially available)
Connection examples
q Communication cable

Port class B
SI unit

Port class A
IO-Link master (Commercially available)
q Communication cable q Communication cable

Port class B
w Y branch connector
SI unit
Power
supply load
e Communication cable

Terminal block wiring type


Port class A
IO-Link master (Commercially available) e Communication cable

Port class B
SI unit
Power
supply load

q Communication cable
EX9-AC  005  -SSPS (With connector on both sides (Socket/Plug))
L
ø14.9

ø14.9

Cable length (L) 3 4 40.7 44.7 2 1


005 500 mm
ø6

5 5
010 1000 mm
2 1 3 4
020 2000 mm
030 3000 mm Socket connector pin arrangement Plug connector pin arrangement
M12 M12
A-coded (Normal key) A-coded (Normal key)
050 5000 mm Core wire
100 10000 mm Terminal no. color Item Specifications
1 1 Brown Cable O.D. ø6 mm
2 2 White
3 3 Blue Conductor nominal cross section 0.3 mm2/AWG22
4 4 Black Wire O.D. (Including conductor) 1.5 mm
5 5 Gray
Min. bending radius (Fixed) 40 mm
Connections

EX9-AC  005  -SAPA (With connector on both sides (Socket/Plug))


ø14.9 ø14.9
M12 M12
Cable length (L) 5 3 2
5
005 500 mm
32.3

010 2 3 1
28.3

1000 mm
ø6

4
020 2000 mm
030 3000 mm 1 4
25.3 25.3
050 5000 mm Socket connector pin arrangement Plug connector pin arrangement
100 10000 mm A-coded (Normal key) L A-coded (Normal key)
Core wire
Terminal no. color Item Specifications
1 1 Brown Cable O.D. ø6 mm
2 2 White
3 3 Blue Conductor nominal cross section 0.3 mm2/AWG22
4 4 Black Wire O.D. (Including conductor) 1.5 mm
5 5 Gray
Min. bending radius (Fixed) 40 mm
Connections
19
Accessories EX260 Series

q Communication Cable

For IO-Link
w Y branch connector
This connector is used to supply power to the valve manifold by branching the IO-Link communication cable
in cases where a port class A IO-Link master is used. 50

EX9-ACY02-S M12
14.12
10.87
4
5
1
3 1 4
5

20.5
35

34
2 3 1
5
3 2
1 2
Socket connector pin arrangement

ø3
q M12 5-pin plug M12 M12 15.5

.5
4 A-coded (Normal key)
1
Plug connector 2
pin arrangement 1 3 M12 5-pin socket
A-coded (Normal key) 4 Solenoid valve power supply cable side pin
1
5
2
arrangement when using a branch connector
w M12 5-pin plug 3 1 — Unused
4 2 SV24V +24 V for solenoid valve
1 5
2 3 — Unused
2 3 4 — Unused
4
5
5 SV0V 0 V for solenoid valve

e Communication cable
EX500-AP  050  -  S
Cable length (L) Connector specification
010 1000 mm S Straight
050 5000 mm A Angled

Straight Angled
ø14.9
connector type M12 connector type
ø14.9

M12
ø6

1 2 1 2
5
ø6
28.3

4 3 27 30 5
4 3 25.3 30 5
Socket connector 40.7 50
Socket connector pin arrangement L 50
pin arrangement L A-coded (Normal key)
A-coded (Normal key)
Item Specifications Item Specifications
Cable O.D. ø6 mm Cable O.D. ø6 mm
Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.5 mm Wire O.D. (Including insulator) 1.5 mm
Min. bending radius (Fixed) 40 mm Min. bending radius (Fixed) 40 mm
Core wire
Terminal no. color
Made to Order 1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
Cable length 10000 mm p. 27 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2
4 Black: IO-Link communication∗1, Not connected∗2
5 Gray: 0 V (Solenoid valve power supply)

Connections *1 When used as an IO-Link communication cable


*2 When used as a solenoid valve power supply cable
(IO-Link)
PCA-  1401804
ø14.8

44.5 L 50

Cable length (L) 5 1 2


1401804 1500 mm
1401805 3000 mm
ø5

4 3
1401806 5000 mm
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Core wire Cable O.D. ø5 mm
Terminal no. color Conductor nominal cross section 0.34 mm2/AWG22
1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
2 White: 24 VDC +10%/–5% (Solenoid valve power supply) Wire O.D. (Including insulator) 1.27 mm
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2 Min. bending radius (Fixed) 21.7 mm
4 Black: IO-Link communication∗1, Not connected∗2
5 Green/Yellow: 0 V (Solenoid valve power supply)

Connections (IO-Link) *1 When used as an IO-Link communication cable *2 When used as a solenoid valve power supply cable
20
EX260 Series

w Field-wireable Communication Connector


Plug

ø17.5
≈ 60
For CC-Link For DeviceNet™

ø19
PCA-1075526 PCA-1075528
A-coded M12 Width across flats 16
(Normal key) SPEEDCON

Applicable Cable

ø17.5
≈ 60 Item Specifications
For PROFIBUS DP Cable O.D. 4.0 to 8.0 mm
PCA-1075530

ø19
0.14 to 0.75 mm2/AWG26 to 18
Wire gauge
(Solid cable/Flexible cable)
(Stranded wire
B-coded M12 0.08 to 0.5 mm2/AWG28 to 20
Width across flats 16 cross section)
(Reverse key) SPEEDCON (With ferrule)

For EtherCAT For PROFINET For EtherNet/IP™ For Ethernet POWERLINK For PROFIsafe
PCA-1446553 ≈ 61

ø17.5
ø19

D-coded M12 Width across flats 16 Width across flats 13

Applicable Cable
Item Specifications
Cable O.D. 4.0 to 8.0 mm
Wire gauge (Stranded wire cross section) 0.14 to 0.34 mm2/AWG26 to 22
* T
 he table above shows the specifications for the applicable cable. Adaptation for the
connector may vary on account of the conductor construction of the electric wire.

Socket
ø17.5

≈ 58
For CC-Link For DeviceNet™
ø19

PCA-1075527 PCA-1075529
A-coded M12
Width across flats 16
(Normal key) SPEEDCON

Applicable Cable
ø17.5

≈ 58
Item Specifications
For PROFIBUS DP Cable O.D. 4.0 to 8.0 mm
0.14 to 0.75 mm2/AWG26 to 18
PCA-1075531
ø19

Wire gauge
(Solid cable/Flexible cable)
(Stranded wire
0.08 to 0.5 mm2/AWG28 to 20
B-coded M12 cross section)
Width across flats 16 (With ferrule)
(Reverse key) SPEEDCON

21
Accessories EX260 Series

e Power Supply Cable (For SI unit)

For PROFIBUS DP For DeviceNet™ For EtherCAT For PROFINET For EtherNet/IP™
For Ethernet POWERLINK For PROFIsafe
EX500-AP  050  -  S
Cable length (L) Connector specification
010 1000 mm S Straight
050 5000 mm A Angled

Straight connector type Angled connector type


ø14.9

M12
1 2
ø6

5 ø14.9 M12

4 3 27 30 5 1 2

ø6
28.3
Socket connector 5
40.7 50
pin arrangement L
A-coded 4 3 25.3 30 5
Socket connector L 50
pin arrangement
A-coded

Item Specifications Item Specifications


Cable O.D. ø6 mm Cable O.D. ø6 mm
Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.5 mm Wire O.D. (Including insulator) 1.5 mm
Min. bending radius (Fixed) 40 mm Min. bending radius (Fixed) 40 mm

Core wire Core wire


Terminal no. color Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply) 1 Brown: Not connected∗1, 24 VDC ±10% (Power supply for control)∗2
2 White: 0 V (Solenoid valve power supply) 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Power supply for control) 3 Blue: Not connected∗1, 0 V (Power supply for control)∗2
4 Black: 0 V (Power supply for control) 4 Black: 0 V (Solenoid valve power supply)
5 Gray: Not connected 5 Gray: Not connected
*1 For DeviceNet™
(
PROFIBUS DP, EtherCAT, PROFINET,
Connections Ethernet POWERLINK, PROFIsafe ) Connections (DeviceNet™, EtherNet/IP™) *2 For EtherNet/IP™

Made to Order
Cable length 10000 mm p. 27

PCA-  1401804
ø14.8

44.5 L 50
5 1 2
Cable length (L)
1401804 1500 mm
ø5

4 3
1401805 3000 mm M12
1401806 5000 mm Socket connector SPEEDCON
pin arrangement
A-coded
Item Specifications
Cable O.D. ø5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.27 mm
Min. bending radius (Fixed) 21.7 mm

Core wire Core wire


Terminal no. color Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply) 1 Brown: Not connected∗1, 24 VDC ±10% (Power supply for control)∗2
2 White: 0 V (Solenoid valve power supply) 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Power supply for control) 3 Blue: Not connected∗1, 0 V (Power supply for control)∗2
4 Black: 0 V (Power supply for control) 4 Black: 0 V (Solenoid valve power supply)
5 Green/Yellow: Not connected 5 Green/Yellow: Not connected
*1 For DeviceNet™
(
PROFIBUS DP, EtherCAT, PROFINET,
Connections Ethernet POWERLINK, PROFIsafe ) Connections (DeviceNet™, EtherNet/IP™) *2 For EtherNet/IP™

22
EX260 Series

r Power Supply Cable (For SI unit/For power block)

For CC-Link For power block


Straight connector type

EX9-AC  050  - 1 L


40.7
1 2
Cable length (L) 5
010 1000 mm

ø6.6
030 3000 mm 4 3 M12 30 5
050 5000 mm
Socket connector 50
pin arrangement
B-coded
Item Specifications
Cable O.D. ø6.6 mm
Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.65 mm
Min. bending radius (Fixed) 40 mm

Core wire
Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
Made to Order Connections 3 Blue: 24 VDC ±10% (Power supply for control)
Black: 0 V (Power supply for control)
4
Cable length 10000 mm p. 27 5 Gray: Not connected∗1, Ground∗2
*1 For CC-Link
*2 For power block

PCA-  1401807   44.5 L 50


5 1 2

Cable length (L)


ø5

1401807 1500 mm 4 3
ø14.8

M12
1401808 3000 mm Socket connector SPEEDCON
1401809 5000 mm pin arrangement Item Specifications
B-coded Cable O.D. ø5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.27 mm
Min. bending radius (Fixed) 21.7 mm

Core wire
Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
Connections 3 Blue: 24 VDC ±10% (Power supply for control)
4 Black: 0 V (Power supply for control)
5 Green/Yellow: Not connected∗1, Ground∗2
*1 For CC-Link
*2 For power block

t Seal Cap (10 pcs.)


Use this on ports that are not being used for communication connector (M12 connector socket).
Use of this seal cap maintains the integrity of the IP67 enclosure.
* Tighten the seal cap with the prescribed tightening torque. (For M12: 0.1 N·m)
14

EX9-AW TS
Connector specification
14

TS For M12 connector socket (10 pcs.)


M12 x 1
10.2
For M12 connector socket

23
Accessories EX260 Series

Output block
P Output devices other than valve manifold can be operated.
Power block P By using the power block and output block for high watt
load, operation up to 0.5 A/point can be performed.
P It is possible to mount the output block and power
block additionally between the SI unit and the
Output device solenoid valve (The surplus I/O points are used).
Solenoid valve
P 2 point outputs per output block (M12 connector)
The output block and power block cannot be used with the
Power supply PROFIsafe compatible SI unit EX260-FPS1.

Others You are requested to connect it to an SI unit and a valve manifold.


Indicator light, Relay, Buzzer For detailed specifications, refer to the operation manual that can
be downloaded from SMC website: https://www.smcworld.com

y Output Block u Power Block


EX9-OE  T   1 EX9-PE1

Output specification
1 Source/PNP (Negative common)
2 Sink/NPN (Positive common)

Power supply type


T Internal power supply method (for low-wattage load)
P Integrated power supply method (for high-wattage load)∗1
∗1 Required to connect with a power block

Dimensions/Parts Description Dimensions/Parts Description


Position indicator LED
Position indicator LED
64.4

64.4
72.6

80.3

PWR

Connector for Power supply connector


21.2 21.2
output device connection (unused)
59.8 59.8 Power supply input connector
(M12, 5 pins, socket,
A-coded) (M12, 5 pins, plug,
B-coded)
43.2

43.2
22.2

22.2

21 21
26.7 26.7
Specifications Specifications
Model EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 Model EX9-PE1
Internal current consumption 40 mA or less Connection block Output block for high wattage load
Source/PNP Sink/NPN Source/PNP Sink/NPN Connection block stations Output block: Max. 8 stations
Output type
(Negative common) (Positive common) (Negative common) (Positive common) Power supply for output Power supply voltage 22.8 to 26.4 VDC
Number of outputs 2 outputs and internal control Internal current consumption 20 mA or less
Output Power supply Internal power Integrated power supply method Supply current Max. 3.1 A∗1
method supply method (Power block: supplied from EX9-PE1) Enclosure IP67
Environmental
Output device supply voltage 24 VDC Operating temperature range –10 to 50°C
resistance
Output device supply current Max. 42 mA/point (1.0 W/point) Max. 0.5 A/point (12 W/point) Operating humidity range 35 to 85% RH (No condensation)
Enclosure IP67 Standards CE marking (EMC directive/RoHS directive), UL (CSA)
Environmental
Operating temperature range –10 to 50°C Weight 120 g
resistance
Operating humidity range 35 to 85% RH (No condensation) Enclosed parts Seal cap (for M12 connector) 1 pc.
Standards CE marking (EMC directive/RoHS directive), UL (CSA) ∗1 When using with 3.0 to 3.1 A, the ambient temperature should not exceed
Weight 120 g 40°C, and do not bundle the cable.

Refer to page 23 for the power supply cable for power block.
24
EX260 Series

i Connector for Output Block Wiring


Field-wireable connector for connecting an output device to an output block

PCA-1557743 (55)
A-coded
2 1
1 Brown: Not connected∗1, 24 V∗2

Width across

ø16.3
ø14.8

2 White: Output 1
Blue: 0 V∗1, Not connected∗2

flats 13
3
4 Black: Output 0
3 4
M12
SPEEDCON Plug pin Connections
arrangement ∗1 When used for EX9-OE1
Applicable Cable ∗2 When used for EX9-OE2
Item Specifications
Cable O.D. 3.5 to 6.0 mm
Wire gauge (Stranded wire cross section) 0.14 to 0.34 mm2/AWG26 to 22
Core wire diameter (Including insulating material) 0.7 to 1.3 mm

PCA-1557756 (55) A-coded


2 1
1 Brown: Not connected∗1, 24 V∗2
Width across
SW15

ø14.8

ø18.4

2 White: Output 1
3 Blue: 0 V∗1, Not connected∗2
flats 15

4 Black: Output 0
3 4
M12
Plug pin Connections
SPEEDCON ∗1 When used for EX9-OE1
arrangement
∗2 When used for EX9-OE2
Applicable Cable
Item Specifications
Cable O.D. 4.0 to 8.0 mm
Wire gauge (Stranded wire cross section) 0.34 to 0.75 mm2/AWG22 to 18
Core wire diameter (Including insulating material) 1.3 to 2.5 mm

Refer to page 23 for the power supply cable for power block.

o End Plate !0 Bracket Plate/DIN Rail Mounting Bracket


Use when an output block is being used and a valve manifold is not A reinforcing brace used to mount an output block or power block onto an SI unit
connected. To prevent connection failure between products due to deflection, use this
bracket plate whenever an output block or power block is mounted.
EX9-EA03
66 EX9-BP1 EX9-BD1
2 x M4 Mounting hole (For VQC, S0700, SV)
2 x M4 Mounting hole 73.6
7.5
12.5

14

11

10
4.2

66 4.5 M4 x 0.7

75 1.2
10
60

13.2

45

Accessory
75 6 18
Description Qty.
Accessory Domed cap nut (M4) 1
Description Qty. Round head combination screw (M4 x 8) 1
Hexagon socket head cap screw (M3 x 35) 2 Round head combination screw (M4 x 10) 1
<Example of use>
<Example of use>

End plate

Bracket plate

DIN rail mounting bracket

25
EX260 Series
Made to Order
Please contact SMC for detailed specifications and lead times.

SI Unit Prepare the SI unit and valve manifold (without SI unit) separately, and combine them before use.

EtherNet/IP™ Web server function compatible


EX260-SEN1-X194
 Web server compatible: Can conduct a solenoid valve operation test
(ON/OFF), check communication state, set QuickConnect™, etc.
 Applicable to the power supply taken from Rockwell Automation’s
safe output module with pulse test function
 Compliant with QuickConnect™ class A specifications
 The gateway address is set to 192.168.m.001 when the IP address
is set by the rotary switch.
 Dimensions are the same as those of the standard type.

Web server screen (Example)

Communication Cable
With connector on one side (Socket) For CC-Link
Cable length: 10000 mm
ø14.8

For CC-Link 44.5 10000 50


22.5
∗1 1 2
For DeviceNet™
4 3
EX9-AC100  MJ  -X12
ø7.7
Marker tag Marker tag Shield
Socket connector pin arrangement
A-coded (Normal key) M12
Applicable protocol ∗1 Number of holes: 5, Total number of pins: 4 SPEEDCON

MJ CC-Link
DN DeviceNet™ Terminal Core wire Item Specifications
no. color
Cable O.D. ø7.7 mm
1 : SLD
2
3
White: DB
Yellow: DG Conductor nominal Data pair 0.5 mm2/AWG20
4 Blue : DA
cross section Drain 0.34 mm2/AWG22
Connections Wire O.D. (Including insulator) 2.55 mm
Min. bending radius (Fixed) 77 mm

For DeviceNet™
ø14.8

44.5 10000 50
22.5
5 1 2

4 3
ø6.7

Marker tag Marker tag


Socket connector pin arrangement
A-coded (Normal key) M12
SPEEDCON

Terminal Core wire Item Specifications


no. color
Cable O.D. ø6.7 mm
1 : DRAIN
2 Red : V+
3 Black: V- Conductor nominal Power pair 0.34 mm2/AWG22
4 White: CAN H
5 Blue : CAN L cross section Data pair 0.25 mm2/AWG24
Connections Wire O.D. (Including Power pair 1.4 mm
insulator) Data pair 2.05 mm
Min. bending radius (Fixed) 67 mm

26
EX260 Series

Power Supply Cable


q With connector on one side (Socket)
Cable length: 10000 mm
10000
40.7
For CC-Link For power block
EX9-AC100-1-X16

ø6.6
M12 30 5
50
Core wire
1 2 Terminal no.
5 color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Power supply for control)
4 3 4 Black: 0 V (Power supply for control)
5 Gray: Not connected∗1, Ground∗2
Socket connector Connections *1 For CC-Link
pin arrangement *2 For power block
B-coded (Reverse key)
Item Specifications
Cable O.D. ø6.6 mm
Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.65 mm
Min. bending radius (Fixed) 40 mm

w With connector on one side (Socket)


Cable length: 10000 mm

For PROFIBUS DP For DeviceNet™ For EtherCAT For PROFINET For EtherNet/IP™
For Ethernet POWERLINK For IO-Link For PROFIsafe
EX500-AP100-  S  -X1
Connector specification
S Straight
A Angled

Straight connector type Angled connector type


ø14.9

M12
ø6

1 2
5 ø14.9 M12

4 3 27 30 5
ø6

1 2
28.3

Socket connector 5
40.7 50
pin arrangement 10000
4 3 25.3 30 5
A-coded
Socket connector 10000 50
pin arrangement
Item Specifications A-coded Item Specifications
Cable O.D. ø6 mm Cable O.D. ø6 mm
Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.5 mm Wire O.D. (Including insulator) 1.5 mm
Min. bending radius (Fixed) 40 mm Min. bending radius (Fixed) 40 mm

Core wire Core wire


Terminal no. color Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply) 1 Brown: Not connected∗1, 24 VDC ±10% (Power supply for control)∗2
2 White: 0 V (Solenoid valve power supply) 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Power supply for control) 3 Blue: Not connected∗1, 0 V (Power supply for control)∗2
4 Black: 0 V (Power supply for control) 4 Black: 0 V (Solenoid valve power supply)
5 Gray: Not connected 5 Gray: Not connected
*1 For DeviceNet™

(
PROFIBUS DP, EtherCAT, PROFINET,
Connections Ethernet POWERLINK, PROFIsafe ) Connections (DeviceNet™, EtherNet/IP™) *2 For EtherNet/IP™

Core wire
Terminal no. color
1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2
4 Black: IO-Link communication∗1, Not connected∗2
5 Gray: 0 V (Solenoid valve power supply)

Connections (IO-Link) *1 When used as an IO-Link communication cable


*2 When used as a solenoid valve power supply cable
27
EX260 Series
Specific Product Precautions
Be sure to read this before handling the products. Refer to the back cover for safety in-
structions. For fieldbus system precautions, refer to the “Handling Precautions for SMC
Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com

Wiring Adjustment / Operation

Caution Caution
1. Select connectors that are ø16 or less if mounting 1. For details on programming and address setting,
valve manifolds directly using field-wireable con- refer to the manual from the PLC manufacturer.
nectors for SI unit power supply wiring. The programming content related to the protocol is designed
Using large diameter connectors causes interference with the by the manufacturer of the PLC used.
mounting surface. 2. For the EX260-SPNm, the side of the SI unit may
The following cables with connectors are recommended. become hot.
 For EX260-SPRm/-SDNm/-SECm/-SPNm/-SENm/-SPLm/ It may cause burns.
-FPS1
<Cable with connector>
¡EX500-APmmm-m
¡PCA-1401804/-1401805/-1401806
 For EX260-SMJm
<Cable with connector>
¡EX9-ACmmm-1
¡PCA-1401807/-1401808/-1401809

Operating Environment

Caution
1. Select the proper type of enclosure according to the
operating environment.
IP67 is achieved when the following conditions are met.
1) Provide appropriate wiring between all units using electrical
wiring cables, communication connectors and cables with
M12 connectors.
2) Appropriately mount each unit and valve manifold.
3) Be sure to mount a seal cap on any unused connectors.
If using in an environment that is exposed to water splashes,
please take measures such as using a cover.
When the enclosure is IP40, do not use in an operating
environment or atmosphere where it may come in contact with
corrosive gas, chemical agents, seawater, water, or water vapor.
When connected to the EX260-SPR5/6/7/8, manifold enclosure
is IP40.

 Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Modbus® is a registered trademark of Schneider Electric, Iicensed to the Modbus Organization, Inc.
QuickConnect™ is a trademark of ODVA.
28
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.

Revision History
Edition B ∗ EtherNet/IP™ has been added to applicable Fieldbus protocols. QS
Edition C ∗ The IO-Link compatible EX260-SIL1 has been added.
∗ Accessories and made-to-order specifications have been added.
∗ “How to Order Manifold” and “Dimensions” pages have been deleted.
∗ Number of pages has been decreased from 52 to 28. XU
Edition D ∗ A functional safety standard compliant product has been added.
∗ Number of pages has been increased from 28 to 32. ZS

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.
INFORMATION

Fieldbus System EX260 Series


SI Unit
LAN cable connectable RJ45 communication
connectors
 Communication protocol: EtherNet/IP™
 Number of outputs: 32

LAN cable*1 connectable


RJ45 communication connectors

 Trademark *1 CAT5 or higher


EtherNet/IP™ is a trademark of ODVA. * Enclosure: IP20
QuickConnect™ is a trademark of ODVA.

 Applicable Valve Series


Flow rate characteristics (4/2  5/3)
Max. number Power consumption Applicable
Series
of solenoids [W] cylinder size
C [dm3/(s·bar)] b

JSY1000 0.91 0.48 0.2 (With power-saving circuit) ø40

JSY Series*2 JSY3000 2.77 0.27 32 0.4 (Standard) ø50


0.1 (With power-saving circuit)
JSY5000 6.59 0.22 ø80

SY3000 1.6 0.19 ø50


0.35 (Standard)
SY Series SY5000 3.6 0.17 32 0.1 (With power-saving circuit)
ø63

SY7000 5.9 0.20 ø80

VQC1000 1.0 0.30 ø40


0.4 (Standard)
VQC2000 3.2 0.30 ø63
VQC Series*2 24
VQC4000 7.3 0.38 0.95 (Standard) ø160
0.4 (Low-wattage type)
VQC5000 17 0.31 ø180

*2 T
 he assembly of JSY and VQC series valves should be requested separately by the customer. Specify “without SI unit” and “positive common” or “non-
polar” for the valve manifold specifications.

EX260-SEN2-X205
19-E731
EX260-SEN2-X205

 Daisy-chain wiring of communication cables and power supply


cables is possible.
Communication cable

Power supply cable

 Compatible Topologies
Ring type Star type Linear type
PLC PLC PLC
Switching hub
(Commercially
available)

* DLR compatible

 Both air and electric systems can be constructed with RJ45


communication cables.
PLC
EX260
EtherNet/IP™

Electric actuator
controller (JXC91)
Electric actuator
controller
(JXC91)

Electric actuator

Electric actuator

Air cylinder

Air cylinder

1
Fieldbus System EX260 Series
SI Unit EX260-SEN2-X205

How to Order SI Units RoHS

EX260 S EN 2 X205
Communication protocol Connector specification
EN EtherNet/IP™ Communication connector: RJ45
X205 Power connector: Spring type connector
Output specification
2 32 outputs, NPN (Positive common)/Sink

Specifications
Item Specifications EtherNet/IP™ communication connector EtherNet/IP™ communication connector
EtherNet/IP™ BUS OUT: RJ45 8 pins, socket BUS IN: RJ45 8 pins, socket
Protocol Volume 1 (Edition 3.25) No. Designation No. Designation No. Designation No. Designation
Volume 2 (Edition 1.23) 1 Tx+ 5 − 1 Tx+ 5 −
Standard Ethernet cable (CAT5 or higher) 2 Tx− 6 Rx− 2 Tx− 6 Rx−
Transmission medium 8 7 6 5 4 3 21 87654321

(100BASE-TX) 3 Rx+ 7 − 3 Rx+ 7 −


Transmission speed 100 Mbps/10 Mbps (Automatic negotiation) 4 − 8 − 4 − 8 −
Transmission method Full duplex/Half duplex (Automatic negotiation)
Vendor ID: 7 (SMC Corp.)
Device information Accessory
Device type: 27 (Pneumatic Valve)
Applicable function QuickConnect™ DLR Description Qty.
EDS file ex260_sen2_X205_24_v*.eds Hexagon socket head cap screw (M3 x 30) 2
Number of outputs 32 RJ45 cap 1
Output type Sink/NPN (Positive common) Power connector 1
Connected Solenoid valve with surge voltage suppressor of
Output load 24 VDC and 1.5 W or less (manufactured by SMC) Power connector PWR: 5 pins, socket
Power supply for 22.8 to 26.4 VDC 1 2 3 4 5
No. Designation Function No. Designation Function
solenoid valve 2.0 A or less, according to the solenoid valve station specification
1 FE Grounding 4 SI0V 0 V for control unit
Residual voltage 0.4 VDC or less
2 SV0V 0 V for solenoid valve 5 SI24V +24 V for control unit
Power supply 21.6 to 26.4 VDC 1 2 3 4 5 3 SV24V +24 V for solenoid valve
for control 0.1 A or less
Enclosure IP20 (with manifold assembled)
Weight 200 g or less (including accessories) Applicable wire for power supply connector
Wire gauge (Solid cable/Flexible cable) 0.2 to 1.5 mm2/AWG24 to 16

Dimensions

LED Indicator
28.2

LED LED Status Details


Power is not being supplied or
OFF
the IP address is not set.
EtherNet/IP™ communication connector BUS OUT Green LED EtherNet/IP™
EtherNet/IP™ communication connector BUS IN is ON communication established
(104) NS Green LED EtherNet/IP™
97.1 is flashing communication not established
87.3 Red LED EtherNet/IP™
is flashing connection time out
Red LED is ON IP duplicated
OFF Power is not being supplied.
17.2 25.8 17.8

Green LED is ON Operating normally


76.5

MS Green LED is flashing Setting error


Red LED is flashing Recoverable error
EX260-SEN2-X205

Red LED is ON Unrecoverable error


OFF BUS IN side: No link, No activity
L/A1 Green LED is ON BUS IN side: Link, No activity
Pin 1 Power connector PWR Output connector (34 pins) Green LED is flashing BUS IN side: Link, Activity
OFF BUS OUT side: No link, No activity
Caution L/A2 Green LED is ON BUS OUT side: Link, No activity
· The dimensions when combined with the valve manifold are the same as the dimensions of the Green LED is flashing BUS OUT side: Link, Activity
valve manifold with a standard EX260 series unit mounted. Yellow LED is ON Power is being supplied to the valve.
· For the JSY and VQC series, order the valve manifold separately. PWR(V) Power is not being supplied to the valve or is
OFF
Specify “without SI unit” and “positive common” or “non-polar” for the valve manifold specifications. outside the tolerance range (19 V or less).

2
EX260-SEN2-X205
RoHS

SY3000/5000/7000 Series How to Order Manifold


Type
10 Side ported
11 Bottom ported*1
*1 The bottom-ported type is not available for the SY3000. A, B port size Mounting and Option
* Refer to the Web Catalog. * Refer to the Web Catalog.
Side/Bottom ported

Type 10/11 SS5Y 3 10 SEC 05 U C6 X1100


Top ported

Type 12 SS5Y 3 12 SEC 05 U X1100


Valve series Mounting
3 SY3000 Nil Direct mounting
5 SY5000 Type D DIN rail mounting (with DIN rail)
7 SY7000 12 Top ported D0 DIN rail mounting (without DIN rail)
D3 For 3 stations Specify a length
Valve stations longer than that of


Symbol Stations Note D24 For 24 stations the standard rail.
02 2 stations
Double wiring*2 P, E port entry P, E port size (One-touch fitting)

16 16 stations U U side (2 to 10 stations) Symbol SY3000 SY5000 SY7000


02 2 stations D D side (2 to 10 stations) Nil ø8 ø10 ø12
Specified layout*3
N ø5/16" ø3/8" ø1/2"

(Up to 32 solenoids available) B Both sides (2 to 24 stations)


24 24 stations * For N, sizes are in inches.

SUP/EXH block assembly


Nil Internal pilot
*2 D ouble wiring: 2-position single, double, 3-position, and 4-position valves can
S Internal pilot, Built-in silencer be used on all manifold stations.
R External pilot Use of a 2-position single solenoid will result in an unused control signal. If
* F or the type 12 top-ported type, the P and E ports are only available this is not desired, order with a specified layout.
on the U and D sides for the built-in silencer type. The silencer exhaust *3 Double wiring is normally used for all the wiring of the manifold. If other wiring
port is located on the opposite side of the P and E port entry. is required, specify on the manifold specification sheet.
(Example: When the P and E port entry is on the D side, the silencer exhaust port is on the U side.) * Valves do not come assembled for order no. “SS5Y-SEC---
The 3/5(E) port on the silencer mounting side of type 10/11/12 is plugged. X1100.” Specify on the manifold specification sheet separately to request
* When the built-in silencer type is used, keep the exhaust port assembly.
from coming into direct contact with water or other liquids. * Produced upon receipt of order

How to Order Valves

SY 5U 1
Enter the standard Enter the standard
product number. product number.

Light/surge voltage suppressor and common specification


Surge voltage Common
Symbol With light
suppressor specification
R —
Non-polar
U V
V
S — Positive
Z V common

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

You might also like