Space-Saving Installation: Fieldbus System
Space-Saving Installation: Fieldbus System
Space-Saving Installation: Fieldbus System
installation
¡IP67
* F
or units with a D-sub connector,
and when connected to S0700 manifolds, it is IP40.
<Compatible Protocols>
Made to Order
Please contact SMC for details on compatible products.
EX260 Series
CAT.E02-25D
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
Existing
model
EX250
Approx.
77 mm
Approx.
81 mm 103 mm Approx.
28 mm
Daisy-chain
wiring
Daisy-chain
wiring
Reduced
wiring space
Wiring and piping from the An external terminating resistor is not necessary.
same direction is possible. (Only available for M12 PROFIBUS DP, CC-Link communication connectors)
(for side ported) ON/OFF switching is possible with an internal terminating resistor.
An external terminating resistor is not necessary.
External terminating
When there is resistor
limited space above
the valve
BUS OUT
1 P 1 P
BUS IN
3/5 E 2 B2 B2 B2 B2 B 3/5 E
PWR
4 A4 A4 A4 A4 A
Internal
terminating
resistor
BUS OUT
1 P 1 P
BUS IN
3/5 E 2 B2 B2 B2 B2 B 3/5 E
PWR
4 A4 A4 A4 A4 A
SI unit Fieldbus
1
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
16
Number of
outputs
32
PNP
Output
polarity
NPN
M12
Communication
connector
D-sub
IP67 *
1
SY3000 1.6 0.19 ø50
0.35 (Standard)
®
SY5000 3.6 0.17 32 0.1 (With power- ø63
saving circuit)
SY7000 5.9 0.20 ø80
IP40 *1, *2
IP67 JSY1000 0.91 0.48 0.2 (With power-saving circuit) ø40
IP67
JSY3000 2.77 0.27 32 0.4 (Standard) ø50
0.1 (With power-
JSY5000 6.59 0.22 saving circuit) ø80
IP67
IP40
IP40 S0700 *3 0.37 0.39 32 0.35 ø25
IP67
SV3000*3 4.3 0.21 ø80
IP40
IP67 *
IP67 1 VQC1000 1.0 0.30 ø40
0.4 (Standard)
VQC2000 3.2 0.30 ø63
24
VQC4000 7.3 0.38 0.95 (Standard) ø160
IP67
IP40
IP67 VQC5000 17 0.31 0.4 (Low-wattage type) ø180
IP67
Safety The use of validated products may be required for valve manifolds used in the safety-related parts of equipment which is
Communication
IP67 compliant with safety standard ISO 13849. For validated products, please contact your SMC sales representative.
*1IP67
Units with a D-sub communication connector are IP40.
*2 The JSY1000 is IP40.
*3IP67
There is no manifold part number setting for the IO-Link compatible SI units.
IP67
2
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
IO-Link compatible
Integratable with various existing networks
IO-Link devices can be easily connected to various networks via the IO-Link master, which acts as a gateway between IO-Link
communication and various Fieldbusses.
Solenoid valves can be connected for communication without relying upon a Fieldbus or PLC.
Fieldbus
IO-Link communication
IO-Link master
(Commercially available)
Power
supply
load
Y Branch Connector
Difference between IO-Link
master port class A and class B Port class A compliant
Pin IO-Link master port pin function A special wiring Y branch 1
no. Port class A Port class B connector is available. Connect to
2
3
1 +24 V +24 V the master 4 1
Additional power 5 2
2 NC/DI/DO Connect to
3
supply +24 V the SI unit
4
3 0V 0V 5
1
4 IO-Link/DI/DO IO-Link/DI/DO
2
Additional power Connect to
3
5 NC Used when connecting to a port power supply 4
supply 0 V
class A type IO-Link master, which is 5
often used when connecting to an
IO-Link sensor
3
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
IO-Link compatible
Features an impressive self-diagnosis function Self-diagnosis contents
Diagnostic contents Event category
Internal failure of the SI unit Error
Output short circuit Error
Output open circuit Error
Solenoid valve power supply failure Warning
Abnormal internal temperature
Warning
of the SI unit
Fieldbus Output switching count value
Notification
exceeded
Process data Service data
IO-Link master
(Commercially available)
Currently
Notification of the at 5 million
fact that the count Currently
operations
threshold has been at 10 million
exceeded operations
4
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
PROFINET/PROFIsafe
compatible PLC
PROFINET/PROFIsafe
A PROFIsafe compatible
PROFIsafe PROFINET PLC allows for the use of a
P RO F I N E T c o m p a t i bl e
SI unit and a PROFIsafe
compatible SI unit to be
used on one communication
line at the same time.
EX260-FPS1 EX260-SPNm
(PROFIsafe compatible SI unit) (PROFINET compatible SI unit)
Safety Output
This product (EX260-FPS1)
has a safety switch inside the Valve
Communication
Internal control unit PROFINET interface
product. It shuts off the voltage RD+
connector 1
supplied to the valve by TD+
Non-safety OUT0
turning OFF the safety switch RD−
control unit OUT1
via directive from the PLC to TD− · ·
enter safe state. The safety
· ·
switch of this product (EX260- Communication RD+ 32 valve · ·
FPS1) has two redundancies, connector 2 outputs
TD+ · ·
one on the 24 V side and the Safety control unit
RD− · ·
other on the 0 V side. It
TD− OUT30
continuously runs diagnostics.
OUT31
The safety switch is turned
OFF in the event of an error DC-DC
Power 24 V PWR
detection. connector Safety switch
0 V PWR
24 V PWR (V)
0 V PWR (V) COM
Safety Definition
The safe state of this product (EX260-FPS1) is a condition in which the safety output described above is turned OFF to shut off the supply of power
to the valve manifold.
This product does not cover valve manifolds that are being used in connection with this product or the safety function and safe state of electric/air
equipment that includes a peripheral circuit.
5
Fieldbus System (Output device for driving 5-port solenoid valves) EX260 Series
For PROFINET/PROFIsafe
PROFINET/PROFIsafe
EX260-FPS1 EX260-FPS1
For PROFINET/PROFIsafe
PROFIsafe PROFINET
Safety output
(Power supply for valve) EX260-SPN EX260-SPN
6
CONTENTS
Fieldbus System How to Order SI Units p. 9
(Output device for driving 5-port solenoid valves) Specifications p. 10
Dimensions p. 12
EX260 Series Parts Description p. 13
LED Indicator p. 14
Accessories
q Communication Cable p. 15
w Field-wireable Communication Connector p. 21
e Power Supply Cable (For SI unit) p. 22
r Power Supply Cable (For SI unit/For power block) p. 23
t Seal Cap (10 pcs.) p. 23
y Output Block p. 24
u Power Block p. 24
i Connector for Output Block Wiring p. 25
o End Plate p. 25
!0 Bracket Plate/DIN Rail Mounting Bracket p. 25
Made to Order
SI Unit
EtherNet/IP™ Web server function compatible p. 26
Communication Cable p. 26
Power Supply Cable p. 27
7
Fieldbus System
For Output
32/16 digital output type available for each unit in the series
Number of outputs (IO-Link and PROFIsafe are only compatible with the 32-point digital output type.)
Negative common (PNP)/positive common (NPN) type available for each unit in the series
Output polarity (Only negative common (PNP) is available for Ethernet POWERLINK, IO-Link, and PROFIsafe.)
Enclosure IP67 (For units with a D-sub connector, and when connected with S0700 manifolds, it is IP40.)
Applicable Manifold
SY3000/5000/7000 JSY1000/3000/5000
VQC1000/2000/4000/5000
S0700 SV1000/2000/3000
D D D
D D D
D D D
D D D
8
EX260 Series
EX260 S PR1
Communication protocol
Symbol Protocol Number of outputs Output polarity Communication connector Manifold symbol Applicable manifold
DN1 Source/PNP (Negative common) QAN
32
DN2 Sink/NPN (Positive common) QA
DeviceNet™ M12
DN3 Source/PNP (Negative common) QBN
16
DN4 Sink/NPN (Positive common) QB
PR1 Source/PNP (Negative common) NAN
32
PR2 Sink/NPN (Positive common) NA
M12
PR3 Source/PNP (Negative common) NBN
16
PR4 Sink/NPN (Positive common) NB
PROFIBUS DP
PR5 Source/PNP (Negative common) NCN
32
PR6 Sink/NPN (Positive common) NC
D-sub∗1
PR7 Source/PNP (Negative common) NDN
16
PR8 Sink/NPN (Positive common) ND
MJ1 Source/PNP (Negative common) VAN
32
MJ2 Sink/NPN (Positive common) VA SY3000/5000/7000
CC-Link M12 JSY1000/3000/5000
MJ3 Source/PNP (Negative common) VBN
16 VQC1000/2000/4000/5000
MJ4 Sink/NPN (Positive common) VB S0700
EC1 Source/PNP (Negative common) DAN SV1000/2000/3000
32
EC2 Sink/NPN (Positive common) DA
EtherCAT M12
EC3 Source/PNP (Negative common) DBN
16
EC4 Sink/NPN (Positive common) DB
PN1 Source/PNP (Negative common) FAN
32
PN2 Sink/NPN (Positive common) FA
PROFINET M12
PN3 Source/PNP (Negative common) FBN
16
PN4 Sink/NPN (Positive common) FB
EN1 Source/PNP (Negative common) EAN
32
EN2 Sink/NPN (Positive common) EA
EtherNet/IP™ M12
EN3 Source/PNP (Negative common) EBN
16
EN4 Sink/NPN (Positive common) EB
PL1 Ethernet 32 GAN
Source/PNP (Negative common) M12
PL3 POWERLINK 16 GBN
SY3000/5000/7000
IL1 IO-Link 32 Source/PNP (Negative common) M12 KAN JSY1000/3000/5000
VQC1000/2000/4000/5000
∗1 Enclosure is IP40 when the communication connector is D-sub.
∗ For “How to Order Manifold Assembly,” refer to the Web Catalog of each valve.
EX260 F PS1
Communication protocol
Symbol Protocol Number of outputs Output polarity Communication connector Manifold symbol Applicable manifold
SY3000/5000/7000
PS1 PROFIsafe 32 Source/PNP (Negative common) M12 FPN JSY1000/3000/5000
VQC1000/2000/4000/5000
* T
he use of validated products may be required for valve manifolds used in the safety-related parts of equipment which is compliant with safety standard
ISO 13849. For validated products, please contact your SMC sales representative.
9
Fieldbus System
For Output EX260 Series
Specifications
All SI Units Common Specifications
Power supply Power supply voltage 21.6 to 26.4 VDC*1
for control Internal current consumption 100 mA or less*4
Power supply for output Power supply voltage 22.8 to 26.4 VDC
Enclosure IP67*2
Operating temperature range −10 to +50°C
Environmental
Operating humidity range 35 to 85% RH (No condensation)
resistance
Withstand voltage 500 VAC for 1 minute between terminals and housing
Insulation resistance 10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Standards CE marking (EMC directive/RoHS directive), UL (CSA) compliant
Weight 200 g
Mounting screw 2 pcs.
Accessories Seal cap
EX9-AWTS (1 pc.)*3
(for M12 connector socket)
*1 T
o serve as the power supply for communication, the power supply voltages are 11 to 25 VDC for the EX260-SDNm, 18 to 30 VDC for the EX260-SIL1,
and 20.4 to 28.8 VDC for the EX260-FPS1.
*2 IP40 applies to EX260-SPR5/6/7/8.
*3 Not provided for EX260-SPR5/6/7/8
*4 200 mA or less for the EX260-FPS1
Specifications
Model EX260-SEN1/3 EX260-SEN2/4 EX260-SPL1 EX260-SPL3 EX260-SIL1 EX260-FPS1
PROFINET/
Protocol EtherNet/IP™*2 Ethernet POWERLINK IO-Link
PROFIsafe*2
PROFINET Specification
Applicable
Volume 1 (Edition 3.17) EPSG DS 301 Version 2.3
system Version*1 V1.1
Volume 2 (Edition 1.18) Version 1.2.0 PROFIsafe Specification
Version 2.4
Configuration file*3 EDS file XDD file IODD file GSD file
I/O occupation area SEN1: 16/32 SEN2: 16/32 0/32
16/32 16/16 0/32*5
(Inputs/Outputs) SEN3: 16/16 SEN4: 16/16 16/32*4
FSU, Shared Device,
Applicable function QuickConnect™, DLR — —
MRP
Communication speed 10 M/100 Mbps*2 100 Mbps*2 COM3/COM2*4 100 Mbps*2
Communication connector specification M12
Terminating resistor switch None (Not required)
Source/PNP Sink/NPN Source/PNP
Output type
(Negative common) (Positive common) (Negative common)
Number of SEN1: 32 points SEN2: 32 points
32 16 32
outputs SEN3: 16 points SEN4: 16 points
11
Fieldbus System
For Output EX260 Series
Dimensions
M12 communication connector type D-sub communication connector type
(EX260-SPR5/6/7/8)
For PROFIBUS DP For DeviceNet™
For PROFIBUS DP
For CC-Link For EtherCAT For PROFINET
For EtherNet/IP™ For Ethernet POWERLINK
90.9
90.9
90.9
90.9
102.4
102.4
102.4
102.4
28.2 28.2 21 21
20.6 20.6
16.4 9
16.4 9 28.2 28.2 28.75 28.7529.25 29.25
9 9
76.5 76.5 76.5 76.5
90.9
102.4
102.4
12
EX260 Series
Parts Description
For PROFIBUS DP For DeviceNet™ For CC-Link Cover screw (M2.5)
Setting switch
Position indicator LED
Output connector
* The
setting switch varies depending on the model.
Refer to the operation manual for details.
It can be downloaded via the SMC website: https://www.smcworld.com
<Connector>
Part no. EX260-SIL1
Cover Communication protocol IO-Link
Setting switch Communication/ 5 pins, plug,*1
Position indicator LED Power connector (M12) A code (SPEEDCON)
Ground terminal M3
*1 T
he communication line, SI unit power supply line, and the
solenoid valve power supply line are connected using the
Output connector same cable.
* T
he setting switch varies depending on the model.
Refer to the operation manual for details.
It can be downloaded via the SMC website: https://www.smcworld.com
13
Fieldbus System
For Output EX260 Series
LED Indicator
MS: SI unit state PWR: Power supply for control RUN: PWR: PWR (V):
Operation state Power supply for control Power supply for solenoid valve
PWR (V): BF: Bus fault PWR: Power supply for control
SF: SI unit diagnosis Power supply for solenoid valve
BF: Communication state PWR: Power supply for control
PWR (V):
SF: SI unit diagnosis Power supply for solenoid valve
BF: Communication state PWR: Power supply for control
14
EX260 Series
Accessories
q Communication Cable
44.5 5000 50
For CC-Link 22.5
∗1 1 2
ø14.8
PCA-1567720
(Socket) 4 3
ø7.7
Marker tag Marker tag Shield
Socket connector pin arrangement M12
A-coded (Normal key) SPEEDCON
∗1 Number of holes: 5,
47.3 5000 50
Total number of pins: 4
22.5
2 1
ø14.8
PCA-1567717
(Plug) 3 4
ø7.7
Marker tag Marker tag Shield
Plug connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Terminal no. Core wire
Cable O.D. ø7.7 mm
color
1 : SLD
Conductor nominal Data pair 0.5 mm2/AWG20
2 White: DB cross section
3 Yellow: DG Drain 0.34 mm2/AWG22
Made to Order 4 Blue: DA
Wire O.D. (Including insulator) 2.55 mm
Cable length 10000 mm p. 26 Connections Min. bending radius (Fixed) 77 mm
ø14.8
Cable length (L) Metal parts 22.5 Metal parts
005 500 mm
010 1000 mm
020 2000 mm
ø7.7
010 1000 mm
ø7.7
8°
15
Accessories EX260 Series
q Communication Cable
44.5 5000 50
For DeviceNet™ 22.5
5 1 2
ø14.8
PCA-1557633
(Socket) 4 3
ø6.7
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) 47.3 5000 50
22.5
5 2 1
ø14.8
PCA-1557646
(Plug) 3 4
ø6.7
Marker tag Marker tag
Plug connector M12
pin arrangement SPEEDCON Item Specifications
A-coded (Normal key)
Cable O.D. ø6.7 mm
Terminal no. Core wire
Conductor nominal Power pair 0.34 mm2/AWG22
color
1 : DRAIN cross section Data pair 0.25 mm2/AWG24
2 Red: V+
3 Black: V- Wire O.D. Power pair 1.4 mm
Made to Order 4
5
White: CAN H
Blue: CAN L
(Including insulator) Data pair 2.05 mm
Cable length 10000 mm p. 26 Connections Min. bending radius (Fixed) 67 mm
ø14.8
Cable length (L) Metal parts 22.5 Metal parts
005 500 mm
010 1000 mm
020 2000 mm
ø6.7
010 1000 mm
30
ø6.7
16
EX260 Series
q Communication Cable
44.5 5000 50
For PROFIBUS DP 22.5
5 1 2
ø14.8
PCA-1557688
(Socket) 4 3
ø7.8
Marker tag Marker tag
Socket connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
47.3 5000 50
22.5
5 2 1
ø14.8
PCA-1557691
(Plug) 3 4
ø7.8
Marker tag Marker tag
Plug connector M12
pin arrangement SPEEDCON
B-coded (Reverse key)
Terminal no. Core wire
color Item Specifications
1 :−
2 Green: A Line Cable O.D. ø7.8 mm
3 :−
4 Red: B Line
5 :− Conductor nominal cross section 0.34 mm2/AWG22
Shield line is connected to the knurl. Wire O.D. (Including insulator) 2.55 mm
Connections Min. bending radius (Fixed) 78 mm
For EtherCAT For PROFINET For EtherNet/IP™ For Ethernet POWERLINK For PROFIsafe
EX9-AC 020 EN-PSRJ (Plug/RJ-45 connector)
M12
ø14.8
010 1000 mm
020 2000 mm
030 3000 mm 47.3 L 44
050 5000 mm
100 10000 mm Signal name Terminal no. Terminal no. Core wire color 1
2 1 2
TD+ 1 1 White/Orange 3
4
RD+ 2 2 Orange 5
3 3 White/Green 6
3 4 TD− 7
4 4 8
RD− 5
Plug connector Green
Plug connector
Metal parts 6
pin arrangement 7 pin arrangement
D-coded 8
Item Specifications
Cable O.D. ø6.4 mm
Conductor nominal cross section 0.14 mm2/AWG26
Wire O.D. (Including insulator) 0.98 mm
Min. bending radius (Fixed) 26 mm
PCA-1446566 (Plug)
ø14.8
47.3 5000 50
2 1
3 4
ø6.5
17
Accessories EX260 Series
q Communication Cable
ø14.8
ø14.8
Cable length (L) 47.3 L 47.3
005 500 mm
010 1000 mm
020 2000 mm
ø6.5
030 3000 mm Metal parts Metal parts
050 5000 mm M12 M12
100 10000 mm SPEEDCON SPEEDCON
Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm
ø6.5
Item Specifications
Cable O.D. ø6.5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 19.5 mm
18
EX260 Series
q Communication Cable
Port class B
SI unit
Port class A
IO-Link master (Commercially available)
q Communication cable q Communication cable
Port class B
w Y branch connector
SI unit
Power
supply load
e Communication cable
Port class B
SI unit
Power
supply load
q Communication cable
EX9-AC 005 -SSPS (With connector on both sides (Socket/Plug))
L
ø14.9
ø14.9
5 5
010 1000 mm
2 1 3 4
020 2000 mm
030 3000 mm Socket connector pin arrangement Plug connector pin arrangement
M12 M12
A-coded (Normal key) A-coded (Normal key)
050 5000 mm Core wire
100 10000 mm Terminal no. color Item Specifications
1 1 Brown Cable O.D. ø6 mm
2 2 White
3 3 Blue Conductor nominal cross section 0.3 mm2/AWG22
4 4 Black Wire O.D. (Including conductor) 1.5 mm
5 5 Gray
Min. bending radius (Fixed) 40 mm
Connections
010 2 3 1
28.3
1000 mm
ø6
4
020 2000 mm
030 3000 mm 1 4
25.3 25.3
050 5000 mm Socket connector pin arrangement Plug connector pin arrangement
100 10000 mm A-coded (Normal key) L A-coded (Normal key)
Core wire
Terminal no. color Item Specifications
1 1 Brown Cable O.D. ø6 mm
2 2 White
3 3 Blue Conductor nominal cross section 0.3 mm2/AWG22
4 4 Black Wire O.D. (Including conductor) 1.5 mm
5 5 Gray
Min. bending radius (Fixed) 40 mm
Connections
19
Accessories EX260 Series
q Communication Cable
For IO-Link
w Y branch connector
This connector is used to supply power to the valve manifold by branching the IO-Link communication cable
in cases where a port class A IO-Link master is used. 50
EX9-ACY02-S M12
14.12
10.87
4
5
1
3 1 4
5
20.5
35
34
2 3 1
5
3 2
1 2
Socket connector pin arrangement
ø3
q M12 5-pin plug M12 M12 15.5
.5
4 A-coded (Normal key)
1
Plug connector 2
pin arrangement 1 3 M12 5-pin socket
A-coded (Normal key) 4 Solenoid valve power supply cable side pin
1
5
2
arrangement when using a branch connector
w M12 5-pin plug 3 1 — Unused
4 2 SV24V +24 V for solenoid valve
1 5
2 3 — Unused
2 3 4 — Unused
4
5
5 SV0V 0 V for solenoid valve
e Communication cable
EX500-AP 050 - S
Cable length (L) Connector specification
010 1000 mm S Straight
050 5000 mm A Angled
Straight Angled
ø14.9
connector type M12 connector type
ø14.9
M12
ø6
1 2 1 2
5
ø6
28.3
4 3 27 30 5
4 3 25.3 30 5
Socket connector 40.7 50
Socket connector pin arrangement L 50
pin arrangement L A-coded (Normal key)
A-coded (Normal key)
Item Specifications Item Specifications
Cable O.D. ø6 mm Cable O.D. ø6 mm
Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.5 mm Wire O.D. (Including insulator) 1.5 mm
Min. bending radius (Fixed) 40 mm Min. bending radius (Fixed) 40 mm
Core wire
Terminal no. color
Made to Order 1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
Cable length 10000 mm p. 27 2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2
4 Black: IO-Link communication∗1, Not connected∗2
5 Gray: 0 V (Solenoid valve power supply)
44.5 L 50
4 3
1401806 5000 mm
Socket connector M12
pin arrangement SPEEDCON
A-coded (Normal key) Item Specifications
Core wire Cable O.D. ø5 mm
Terminal no. color Conductor nominal cross section 0.34 mm2/AWG22
1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
2 White: 24 VDC +10%/–5% (Solenoid valve power supply) Wire O.D. (Including insulator) 1.27 mm
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2 Min. bending radius (Fixed) 21.7 mm
4 Black: IO-Link communication∗1, Not connected∗2
5 Green/Yellow: 0 V (Solenoid valve power supply)
Connections (IO-Link) *1 When used as an IO-Link communication cable *2 When used as a solenoid valve power supply cable
20
EX260 Series
ø17.5
≈ 60
For CC-Link For DeviceNet™
ø19
PCA-1075526 PCA-1075528
A-coded M12 Width across flats 16
(Normal key) SPEEDCON
Applicable Cable
ø17.5
≈ 60 Item Specifications
For PROFIBUS DP Cable O.D. 4.0 to 8.0 mm
PCA-1075530
ø19
0.14 to 0.75 mm2/AWG26 to 18
Wire gauge
(Solid cable/Flexible cable)
(Stranded wire
B-coded M12 0.08 to 0.5 mm2/AWG28 to 20
Width across flats 16 cross section)
(Reverse key) SPEEDCON (With ferrule)
For EtherCAT For PROFINET For EtherNet/IP™ For Ethernet POWERLINK For PROFIsafe
PCA-1446553 ≈ 61
ø17.5
ø19
Applicable Cable
Item Specifications
Cable O.D. 4.0 to 8.0 mm
Wire gauge (Stranded wire cross section) 0.14 to 0.34 mm2/AWG26 to 22
* T
he table above shows the specifications for the applicable cable. Adaptation for the
connector may vary on account of the conductor construction of the electric wire.
Socket
ø17.5
≈ 58
For CC-Link For DeviceNet™
ø19
PCA-1075527 PCA-1075529
A-coded M12
Width across flats 16
(Normal key) SPEEDCON
Applicable Cable
ø17.5
≈ 58
Item Specifications
For PROFIBUS DP Cable O.D. 4.0 to 8.0 mm
0.14 to 0.75 mm2/AWG26 to 18
PCA-1075531
ø19
Wire gauge
(Solid cable/Flexible cable)
(Stranded wire
0.08 to 0.5 mm2/AWG28 to 20
B-coded M12 cross section)
Width across flats 16 (With ferrule)
(Reverse key) SPEEDCON
21
Accessories EX260 Series
For PROFIBUS DP For DeviceNet™ For EtherCAT For PROFINET For EtherNet/IP™
For Ethernet POWERLINK For PROFIsafe
EX500-AP 050 - S
Cable length (L) Connector specification
010 1000 mm S Straight
050 5000 mm A Angled
M12
1 2
ø6
5 ø14.9 M12
4 3 27 30 5 1 2
ø6
28.3
Socket connector 5
40.7 50
pin arrangement L
A-coded 4 3 25.3 30 5
Socket connector L 50
pin arrangement
A-coded
Made to Order
Cable length 10000 mm p. 27
PCA- 1401804
ø14.8
44.5 L 50
5 1 2
Cable length (L)
1401804 1500 mm
ø5
4 3
1401805 3000 mm M12
1401806 5000 mm Socket connector SPEEDCON
pin arrangement
A-coded
Item Specifications
Cable O.D. ø5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.27 mm
Min. bending radius (Fixed) 21.7 mm
22
EX260 Series
ø6.6
030 3000 mm 4 3 M12 30 5
050 5000 mm
Socket connector 50
pin arrangement
B-coded
Item Specifications
Cable O.D. ø6.6 mm
Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.65 mm
Min. bending radius (Fixed) 40 mm
Core wire
Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
Made to Order Connections 3 Blue: 24 VDC ±10% (Power supply for control)
Black: 0 V (Power supply for control)
4
Cable length 10000 mm p. 27 5 Gray: Not connected∗1, Ground∗2
*1 For CC-Link
*2 For power block
1401807 1500 mm 4 3
ø14.8
M12
1401808 3000 mm Socket connector SPEEDCON
1401809 5000 mm pin arrangement Item Specifications
B-coded Cable O.D. ø5 mm
Conductor nominal cross section 0.34 mm2/AWG22
Wire O.D. (Including insulator) 1.27 mm
Min. bending radius (Fixed) 21.7 mm
Core wire
Terminal no. color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
Connections 3 Blue: 24 VDC ±10% (Power supply for control)
4 Black: 0 V (Power supply for control)
5 Green/Yellow: Not connected∗1, Ground∗2
*1 For CC-Link
*2 For power block
EX9-AW TS
Connector specification
14
23
Accessories EX260 Series
Output block
P Output devices other than valve manifold can be operated.
Power block P By using the power block and output block for high watt
load, operation up to 0.5 A/point can be performed.
P It is possible to mount the output block and power
block additionally between the SI unit and the
Output device solenoid valve (The surplus I/O points are used).
Solenoid valve
P 2 point outputs per output block (M12 connector)
The output block and power block cannot be used with the
Power supply PROFIsafe compatible SI unit EX260-FPS1.
Output specification
1 Source/PNP (Negative common)
2 Sink/NPN (Positive common)
64.4
72.6
80.3
PWR
43.2
22.2
22.2
21 21
26.7 26.7
Specifications Specifications
Model EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 Model EX9-PE1
Internal current consumption 40 mA or less Connection block Output block for high wattage load
Source/PNP Sink/NPN Source/PNP Sink/NPN Connection block stations Output block: Max. 8 stations
Output type
(Negative common) (Positive common) (Negative common) (Positive common) Power supply for output Power supply voltage 22.8 to 26.4 VDC
Number of outputs 2 outputs and internal control Internal current consumption 20 mA or less
Output Power supply Internal power Integrated power supply method Supply current Max. 3.1 A∗1
method supply method (Power block: supplied from EX9-PE1) Enclosure IP67
Environmental
Output device supply voltage 24 VDC Operating temperature range –10 to 50°C
resistance
Output device supply current Max. 42 mA/point (1.0 W/point) Max. 0.5 A/point (12 W/point) Operating humidity range 35 to 85% RH (No condensation)
Enclosure IP67 Standards CE marking (EMC directive/RoHS directive), UL (CSA)
Environmental
Operating temperature range –10 to 50°C Weight 120 g
resistance
Operating humidity range 35 to 85% RH (No condensation) Enclosed parts Seal cap (for M12 connector) 1 pc.
Standards CE marking (EMC directive/RoHS directive), UL (CSA) ∗1 When using with 3.0 to 3.1 A, the ambient temperature should not exceed
Weight 120 g 40°C, and do not bundle the cable.
Refer to page 23 for the power supply cable for power block.
24
EX260 Series
PCA-1557743 (55)
A-coded
2 1
1 Brown: Not connected∗1, 24 V∗2
Width across
ø16.3
ø14.8
2 White: Output 1
Blue: 0 V∗1, Not connected∗2
flats 13
3
4 Black: Output 0
3 4
M12
SPEEDCON Plug pin Connections
arrangement ∗1 When used for EX9-OE1
Applicable Cable ∗2 When used for EX9-OE2
Item Specifications
Cable O.D. 3.5 to 6.0 mm
Wire gauge (Stranded wire cross section) 0.14 to 0.34 mm2/AWG26 to 22
Core wire diameter (Including insulating material) 0.7 to 1.3 mm
ø14.8
ø18.4
2 White: Output 1
3 Blue: 0 V∗1, Not connected∗2
flats 15
4 Black: Output 0
3 4
M12
Plug pin Connections
SPEEDCON ∗1 When used for EX9-OE1
arrangement
∗2 When used for EX9-OE2
Applicable Cable
Item Specifications
Cable O.D. 4.0 to 8.0 mm
Wire gauge (Stranded wire cross section) 0.34 to 0.75 mm2/AWG22 to 18
Core wire diameter (Including insulating material) 1.3 to 2.5 mm
Refer to page 23 for the power supply cable for power block.
14
11
10
4.2
66 4.5 M4 x 0.7
75 1.2
10
60
13.2
45
Accessory
75 6 18
Description Qty.
Accessory Domed cap nut (M4) 1
Description Qty. Round head combination screw (M4 x 8) 1
Hexagon socket head cap screw (M3 x 35) 2 Round head combination screw (M4 x 10) 1
<Example of use>
<Example of use>
End plate
Bracket plate
25
EX260 Series
Made to Order
Please contact SMC for detailed specifications and lead times.
SI Unit Prepare the SI unit and valve manifold (without SI unit) separately, and combine them before use.
Communication Cable
With connector on one side (Socket) For CC-Link
Cable length: 10000 mm
ø14.8
MJ CC-Link
DN DeviceNet™ Terminal Core wire Item Specifications
no. color
Cable O.D. ø7.7 mm
1 : SLD
2
3
White: DB
Yellow: DG Conductor nominal Data pair 0.5 mm2/AWG20
4 Blue : DA
cross section Drain 0.34 mm2/AWG22
Connections Wire O.D. (Including insulator) 2.55 mm
Min. bending radius (Fixed) 77 mm
For DeviceNet™
ø14.8
44.5 10000 50
22.5
5 1 2
4 3
ø6.7
26
EX260 Series
ø6.6
M12 30 5
50
Core wire
1 2 Terminal no.
5 color
1 Brown: 24 VDC +10%/–5% (Solenoid valve power supply)
2 White: 0 V (Solenoid valve power supply)
3 Blue: 24 VDC ±10% (Power supply for control)
4 3 4 Black: 0 V (Power supply for control)
5 Gray: Not connected∗1, Ground∗2
Socket connector Connections *1 For CC-Link
pin arrangement *2 For power block
B-coded (Reverse key)
Item Specifications
Cable O.D. ø6.6 mm
Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.65 mm
Min. bending radius (Fixed) 40 mm
For PROFIBUS DP For DeviceNet™ For EtherCAT For PROFINET For EtherNet/IP™
For Ethernet POWERLINK For IO-Link For PROFIsafe
EX500-AP100- S -X1
Connector specification
S Straight
A Angled
M12
ø6
1 2
5 ø14.9 M12
4 3 27 30 5
ø6
1 2
28.3
Socket connector 5
40.7 50
pin arrangement 10000
4 3 25.3 30 5
A-coded
Socket connector 10000 50
pin arrangement
Item Specifications A-coded Item Specifications
Cable O.D. ø6 mm Cable O.D. ø6 mm
Conductor nominal cross section 0.3 mm2/AWG22 Conductor nominal cross section 0.3 mm2/AWG22
Wire O.D. (Including insulator) 1.5 mm Wire O.D. (Including insulator) 1.5 mm
Min. bending radius (Fixed) 40 mm Min. bending radius (Fixed) 40 mm
(
PROFIBUS DP, EtherCAT, PROFINET,
Connections Ethernet POWERLINK, PROFIsafe ) Connections (DeviceNet™, EtherNet/IP™) *2 For EtherNet/IP™
Core wire
Terminal no. color
1 Brown: 18 to 30 VDC (Power supply for control)∗1, Not connected∗2
2 White: 24 VDC +10%/–5% (Solenoid valve power supply)
3 Blue: 0 V (Power supply for control)∗1, Not connected∗2
4 Black: IO-Link communication∗1, Not connected∗2
5 Gray: 0 V (Solenoid valve power supply)
Caution Caution
1. Select connectors that are ø16 or less if mounting 1. For details on programming and address setting,
valve manifolds directly using field-wireable con- refer to the manual from the PLC manufacturer.
nectors for SI unit power supply wiring. The programming content related to the protocol is designed
Using large diameter connectors causes interference with the by the manufacturer of the PLC used.
mounting surface. 2. For the EX260-SPNm, the side of the SI unit may
The following cables with connectors are recommended. become hot.
For EX260-SPRm/-SDNm/-SECm/-SPNm/-SENm/-SPLm/ It may cause burns.
-FPS1
<Cable with connector>
¡EX500-APmmm-m
¡PCA-1401804/-1401805/-1401806
For EX260-SMJm
<Cable with connector>
¡EX9-ACmmm-1
¡PCA-1401807/-1401808/-1401809
Operating Environment
Caution
1. Select the proper type of enclosure according to the
operating environment.
IP67 is achieved when the following conditions are met.
1) Provide appropriate wiring between all units using electrical
wiring cables, communication connectors and cables with
M12 connectors.
2) Appropriately mount each unit and valve manifold.
3) Be sure to mount a seal cap on any unused connectors.
If using in an environment that is exposed to water splashes,
please take measures such as using a cover.
When the enclosure is IP40, do not use in an operating
environment or atmosphere where it may come in contact with
corrosive gas, chemical agents, seawater, water, or water vapor.
When connected to the EX260-SPR5/6/7/8, manifold enclosure
is IP40.
Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Modbus® is a registered trademark of Schneider Electric, Iicensed to the Modbus Organization, Inc.
QuickConnect™ is a trademark of ODVA.
28
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.
Revision History
Edition B ∗ EtherNet/IP™ has been added to applicable Fieldbus protocols. QS
Edition C ∗ The IO-Link compatible EX260-SIL1 has been added.
∗ Accessories and made-to-order specifications have been added.
∗ “How to Order Manifold” and “Dimensions” pages have been deleted.
∗ Number of pages has been decreased from 52 to 28. XU
Edition D ∗ A functional safety standard compliant product has been added.
∗ Number of pages has been increased from 28 to 32. ZS
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.
INFORMATION
*2 T
he assembly of JSY and VQC series valves should be requested separately by the customer. Specify “without SI unit” and “positive common” or “non-
polar” for the valve manifold specifications.
EX260-SEN2-X205
19-E731
EX260-SEN2-X205
Compatible Topologies
Ring type Star type Linear type
PLC PLC PLC
Switching hub
(Commercially
available)
* DLR compatible
Electric actuator
controller (JXC91)
Electric actuator
controller
(JXC91)
Electric actuator
Electric actuator
Air cylinder
Air cylinder
1
Fieldbus System EX260 Series
SI Unit EX260-SEN2-X205
EX260 S EN 2 X205
Communication protocol Connector specification
EN EtherNet/IP™ Communication connector: RJ45
X205 Power connector: Spring type connector
Output specification
2 32 outputs, NPN (Positive common)/Sink
Specifications
Item Specifications EtherNet/IP™ communication connector EtherNet/IP™ communication connector
EtherNet/IP™ BUS OUT: RJ45 8 pins, socket BUS IN: RJ45 8 pins, socket
Protocol Volume 1 (Edition 3.25) No. Designation No. Designation No. Designation No. Designation
Volume 2 (Edition 1.23) 1 Tx+ 5 − 1 Tx+ 5 −
Standard Ethernet cable (CAT5 or higher) 2 Tx− 6 Rx− 2 Tx− 6 Rx−
Transmission medium 8 7 6 5 4 3 21 87654321
Dimensions
LED Indicator
28.2
2
EX260-SEN2-X205
RoHS
…
Symbol Stations Note D24 For 24 stations the standard rail.
02 2 stations
Double wiring*2 P, E port entry P, E port size (One-touch fitting)
…
SY 5U 1
Enter the standard Enter the standard
product number. product number.
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.