Microprocessor Bargraphic

Display Scaling Meter

www.fine-tek.com
INTRODUCTION

FEATURES
Adapts microprocessor control circuit,
modular design, advanced digital
calibration, and switching power supply
technology.
Modulized design is a concept to adapt different
analog input signals by means of changing
different signal board (such as temperature,
pressure, alternating voltage, electric current.).
Also, optional output board could add the analog
output signal (isolated). By using advanced digital
calibration capability, its analog input/output could
be accurate to +/- 1 bit.

PB SERIES---BARGRAPH DISPLAY PM SERIES---DIGITAL DISPLAY


It is easy to tell the measuring, operator can PM-2430 is designed for dual channel applications.
tell measuring range easily by eyesight even in It can measure 2 input signals simultaneously by
the remote site.
only one meter. Also, it supports 2 channels analog
Provides not only 4 digits numerical display output signals and 2 relay contacts. To users, it
with bargraph analog output indicator but also provides both convenient panel layout operation and
6 relay setting points. It makes users to tell relatively lower cost when compared with using two
Process setting position without difficulties by
panel meters.
bargraph indicator. In general, it is an easy
applied and understand model to customers.

PB-2471 is designed for dual channel PM-1530/1430 are single channel models with 5-
applications. It can measure 2 input signals digit or 4 digit LED display respectively.
simultaneously by only one meter. Also, it
supports 2 channels analog output signals and
4 relay contacts. To users, it provides both
convenient panel layout operation and
relatively lower cost when compared with using
two panel meters.

PB-1570 and PB-1470 are horizotal mounting


design, all functions are same as vertical
models.

1
NON-LINEAR TANK VOLUME CONVERSION FEATURE

NON-LINEAR TANK VOLUME


CONVERSION FEATURE
PM/PB Series support volume adjustment function for
non-linear tanks. By means of a 20-point look-up table,
panel meter calculate tank volume according to the
material level measured.
Bundled with this package, a software is provided, user
simply select tank type shown as below, and enter
necessary dimension, tank volume and 20 control
points will be calculated and reported.

TANK TYPE:
Length
Width
Length
Height 1
Height
Diameter
Height 2

Width

Length Width
Diameter
Diameter

Height 1 Height 1
Height
Height 2
Height 2

Diameter
Length Length

Height 1

Diameter Diameter

Height 2

Length

Width
Length
Height 2
Height 1
Height

2
SPECIFICATIONS

Microprocessor Bargraph Display Panel Meter

Appearance

Dimension 48 (W) x144 (H) x121.5 (D) 48 (W) x144 (H) x121.5 (D) 144 (W) x48 (H) x121.5 (D) 144 (W) x48 (H) x121.5 (D)
(mm) DIN 3/16 DIN 3/16 DIN 3/16 DIN 3/16

Model PB-2471 PB-1471 PB-1470 PB-1570

Dual Row 4-digit 7-segment LED 4 Digits 7-Segment LED 4 Digits 7-Segment LED 5 Digits 7-Segment LED
Dual Column 101-segment LED 101 LED Bargraph Display 101 LED Bargraph Display 101 LED Bargraph Display
Display Bargraph Display Totally 6 Set Points Totally 6 Set Points Totally 6 Set Points
Totally 8 Set Points

Display
Range -1999 ~ +9999。 -1999 ~ +9999。 -1999 ~ +9999。 -19999 ~ +32767。

20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V,
Input 20V ,200V 20V ,200V 20V ,200V 20V ,200V
Standard

signal (Refer to Input Signal Setting) (Refer to Input Signal Setting) (Refer to Input Signal Setting) (Refer to Input Signal Setting)

Relay
contact 4 Relay 4 Relay 4 Relay 4 Relay

Power 85 ~ 265V AC or 85 ~ 265V AC or 85 ~ 265V AC or 85 ~ 265V AC or


supply 18 ~ 36V DC 18 ~ 36V DC 18 ~ 36V DC 18 ~ 36V DC

Relay Expand to 8 Relay Expand to 6 Relay Expand to 6 Relay Expand to 6 Relay

Analog 4~20mA, 0~20mA, 2~10V 4~20mA, 0~20mA, 2~10V 4~20mA, 0~20mA, 2~10V 4~20mA, 0~20mA, 2~10V
Optional

output and 0~10V and 0~10V and 0~10V and 0~10V

Communi-
cation port RS-485 (Modbus) RS-485 (Modbus) RS-485 (Modbus) RS-485 (Modbus)

Non-Linear Non-Linear Tank Volume Non-Linear Tank Volume Non-Linear Tank Volume Non-Linear Tank Volume
Function Conversion Feature ( 20 points) Conversion Feature ( 20 points) Conversion Feature ( 20 points) Conversion Feature ( 20 points)

3
SPECIFICATIONS

Microprocessor Digit Display Panel Meter

Appearance

Dimension 96 (W) x48 (H) x128.5 (D) 96 (W) x48 (H) x128.5 (D) 96 (W) x48 (H) x128.5(D) 96 (W) x48 (H) x128.5(D)
(mm) DIN 1/8 DIN 1/8 DIN 1/8 DIN 1/8

Model PM-1430-W (4 digit)


PM-1430 PM-2430 PM-1530 PM-1530-W (5 digit)

Dual Channel Signal Input


4 Digits 7-Segment LED 5 Digits 7-Segment LED 5 Digits 7-Segment LED
Display Totally 4 Set Points
Dual 4 Digits LED Numeric Display
Totally 4 Set Points Totally 4 Set Points
Totally 4 Set Points

Display -1999 ~ +9999。


range -1999 ~ +9999。 -1999 ~ +9999。 -19999 ~ +32767。
-19999 ~ +99999。

20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V, 20mA, 200mA, 5V, 10V,
Input 20V ,200V 20V ,200V 20V ,200V 20V ,200V
Standard

signal (Refer to Input Signal Setting) (Refer to Input Signal Setting) (Refer to Input Signal Setting) (Refer to Input Signal Setting)

Relay
2 Relay 4 Relay 2 Relay 4 Relay
contact

Power 85 ~ 265V AC or 85 ~ 265V AC or 85 ~ 265V AC or


supply 20 ~ 250Vac/Vdc 50/60Hz
18 ~ 36V DC 18 ~ 36V DC 18 ~ 36V DC

Relay Expand to 4 Relay Expand to 4 Relay

Analog 4~20mA, 0~20mA, 2~10V 4~20mA, 0~20mA, 2~10V 4~20mA, 0~20mA, 2~10V
4~20mA, 0~20mA, 2~10V
Optional

output and 0~10V and 0~10V and 0~10V


and 0~10V

Communi-
cation port RS-485 (Modbus) RS-485 (Modbus) RS-485 (Modbus) RS-485 (Modbus)

Non-Linear Non-Linear Tank Volume And


Non-Linear Tank Volume Non-Linear Tank Volume Non-Linear Tank Volume
Input Signal Conversion
function Conversion Feature ( 20 points) Conversion Feature ( 20 points) Conversion Feature ( 20 points)
( each 20 points)

4
Microprocessor Bargraph
PB-2471
Display Panel Meter

TERMINAL (Option)
Isolated
ARRANGEMENTS: EXC 24V 1 19 +24V
GND
GND 2 20
Volt Input 3 21 Analog O/P+
Current Input 4
{ CH1 22 Analog GND { CH1
Analog O/P+
Signal GND
Volt Input
5
6
23
24 Analog GND
{ CH2
Current Input
Signal GND
7
8
{ CH2

9 25 + {
CH2 SP2 RS485
10 26 -
11 27
CH2 SP1
12 28
13 29
CH1 SP2 CH2 SP4
14 30
15 31
CH1 SP1 CH2 SP3
16 32
AUX. 17 33
CH1 SP4
POWER 18 34
35
CH1 SP3
FEATURES: 36

Dual 4 Digits LED Numeric Display EXTERIOR/CUTOUT DIMENSIONS ( Unit:mm)


6 (max.)
Dual 101-segment LED Bargraph display 48 45 +0.6
-0 10 (min.)

Wide Range of User Definable Scaling Ratio


Modulized input signal boards available for
different applications
Optional Output Boards with Isolated Analog Output 144 137.8 138 +1
-0

& Relay Output


85V~265VAC or 18~36VDC Switching Power Supply
Support volume adjustment function for non-linear tanks
(optional)
9 111 22 10
(min.)

SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 48 (W) x144 (H) x121.5 (D) DIN 3/16 PB-2471-9 99-9 9 9 9
Model PB-2471 Power S---85~265V AC
supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 1---4~20mA DC with Exc 24V
Power supply Switching Power Supply Input
2---0~20 mA DC with Exc 24V
signal
3---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA (CH1)
4---5V DC with Exc 24V
5---10V DC with Exc 24V
Dual 4 Digits, 0.36" 7-Segment LED 6---20V DC with Exc 24V
7---200V DC with Exc 24V
Display
101 LED Bargraph Display
Display Input 1---4~20mA DC with Exc 24V
4 LED set-point indicator signal 2---0~20 mA DC with Exc 24V
(CH2) 3---0~200 mA DC with Exc 24V
Display Range: -1999 ~ +9999 4---5V DC with Exc 24V
5---10V DC with Exc 24V
Over Range Display: "1" or "-1" 6---20V DC with Exc 24V
7---200V DC with Exc 24V

Range: Refer to Ordering information


Accuracy: 0.1%FS or A1 digit
Temperature coefficient: 200ppm/℃
Input signal
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact
0---0 Relays 2---2 Relays 4---4 Relays 8---8 Relays
2 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
4 relay (up to 8 relay)
0---Without
Relay contact 3A/250V AC or 5A/30V DC Analog 5---Dual Analog output, 0~10V
output 6---Dual Analog output, 0/4~20mA
(N.C. / N.O. Jumper selectable)

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 12VA
Communication port RS485 (optional) Modbus Protocol Ex: PB-2471-S14-4000
Represents: PB-2471 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal, CH1: 4~20mA, CH2: 0~5V,
Storage condition 0~70℃(20 to 90% RH non-condensed) 4 relay contact, without Non-Linear Function,
without Analog output.
5
Microprocessor Bargraph
PB-1471
Display Panel Meter

TERMINAL (Option)
Isolated
ARRANGEMENTS: EXC 24V 1 19 +24V
GND 2 20 GND
Volt Input Signal 3 21 Analog O/P+
Current Input Signal 4 22 Analog GND
Signal GND 5 23
6 24
7
8

9 25 + {
SP4 RS485
10 26 -
11 27
SP3
12 28
13 29
SP2 Option
14 30
15 31
SP1
16 32
AUX. 17 33
POWER SP6
18 34
35
SP5
FEATURES: 36

4 Digits LED Numeric Display EXTERIOR/CUTOUT DIMENSIONS


6 (max.)
101-segment LED Bargraph display 48 45 +0.6
-0 10 (min.)

Wide Range of User Definable Scaling Ratio


Modulized input signal boards available for
different applications
Optional Output Boards with Isolated Analog Output 144 137.8 138 +1
-0

& Relay Output


85V~265VAC or 18~36VDC Switching Power Supply
Support volume adjustment function for non-linear tanks
(optional)
9 111 22 10
(min.)

SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 48 (W) x144 (H) x121.5 (D) DIN 3/16 PB-1471-9 99-9 9 9 9
Model PB-1471 Power S---85~265V AC
supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 01---4~20mA DC with Exc 24V
Power SUPply Switching Power Supply 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA 04---5V DC with Exc 24V
05---10V DC with Exc 24V
4 Digits, 0.36" 7-Segment red LED 06---20V DC with Exc 24V
07---200V DC with Exc 24V
Display
Input
101 LED Bargraph Display signal
Display
6 LED set-point indicator A1---2mA AC RMS C1---K2 mA DC with Exc 24V
A2---20mA AC RMS C2---K20 mA DC with Exc 24V
Display Range: -1999 ~ +9999 A3---200mA AC RMS C3---K200 mA DC with Exc 24V
A4---1A AC RMS C4---K1Amp DC
Over Range Display: "1" or "-1" A5---5A AC RMS C5---K5Amp DC

B1---100mV AC RMS D1---K20mV DC with Exc 24V


B2---200mV AC RMS D2---K50mV DC with Exc 24V
Range: Refer to Ordering information B3---2V AC RMS D3---K100mV DC with Exc 24V
Accuracy: 0.1%FS or A1 digit B4---20V AC RMS D4---K200mV DC with Exc 24V
B5---200V AC RMS
Temperature coefficient: 200ppm/℃
Input signal B6---600V AC RMS
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact 0---0 Relays 2---2 Relays 4---4 Relays 6---6 Relays
4 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
4 relay (up to 6 relay)
Relay contact 3A/250V AC or 5A/30V DC 0---Without
Analog
1---0~10V Analog Output
(N.C. / N.O. Jumper selectable) output
2---0/4~20mA Analog Output

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 9VA
Communication port RS485 (optional) Modbus Protocol EX: PB-1471-S01-4101
Represents: PB-1471 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Storage condition Support Non-Linear Function, without Analog
0~70℃(20 to 90% RH non-condensed)
output, Support RS485 interface.
6
Microprocessor Bargraph
PB-1470
Display Panel Meter

TERMINAL
ARRANGEMENTS:
Isolated
Analog
+24V GND
OUT GND RS485
SP6 SP5
+ -

19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
(Option)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

SP4 SP3 SP2 SP1 AUX.


EXC GND V A GND
+24V IN IN POWER

FEATURES: EXTERIOR/CUTOUT DIMENSIONS


4 Digits LED Numeric Display
101-segment LED Bargraph display 144

Wide Range of User Definable Scaling Ratio 10


48 (min.)
Modulized input signal boards available for
different applications
111 21
Optional Output Boards with Isolated Analog Output 45 +0.6
-0

& Relay Output 44.8


85V~265VAC or 18~36VDC Switching Power Supply 138 +1
-0 10
7 (min.)
Support volume adjustment function for non-linear tanks
(optional)

SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 144 (W) x48 (H) x121.5 (D) DIN 3/16 PB-1470-9 99-9 9 9 9
Model PB-1470 Power S---85~265V AC
supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 01---4~20mA DC with Exc 24V
Power supply Switching Power Supply 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA 04---5V DC with Exc 24V
05---10V DC with Exc 24V
4 Digits, 0.56" 7-Segment red LED 06---20V DC with Exc 24V
07---200V DC with Exc 24V
Display
Input
101 LED Bargraph Display signal
Display
6 LED set-point indicator A1---2mA AC RMS C1---K2 mA DC with Exc 24V
A2---20mA AC RMS C2---K20 mA DC with Exc 24V
Display Range: -1999 ~ +9999 A3---200mA AC RMS C3---K200 mA DC with Exc 24V
A4---1A AC RMS C4---K1Amp DC
Over Range Display: "1" or "-1" A5---5A AC RMS C5---K5Amp DC

B1---100mV AC RMS D1---K20mV DC with Exc 24V


Range: Refer to Ordering information B2---200mV AC RMS D2---K50mV DC with Exc 24V
B3---2V AC RMS D3---K100mV DC with Exc 24V
Accuracy: 0.1%FS or A1 digit B4---20V AC RMS D4---K200mV DC with Exc 24V
Temperature coefficient: 200ppm/℃ B5---200V AC RMS
Input signal B6---600V AC RMS
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact 0---0 Relays 2---2 Relays 4---4 Relays 6---6 Relays
4 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
4 relay (up to 6 relay)
Relay contact 3A/250V AC or 5A/30V DC Analog
0---Without
1---0~10V Analog Output
(N.C. / N.O. Jumper selectable) output
2---0/4~20mA

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 9VA
Communication port RS485 (optional) Modbus Protocol EX: PB-1470-S01-4101
Represents: PB-1470 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Storage condition Support Non-Linear Function, without Analog
0~70℃(20 to 90% RH non-condensed)
output, Support RS485 interface.
7
Microprocessor Bargraph
PB-1570
Display Panel Meter

TERMINAL
ARRANGEMENTS:
Isolated
Analog
+24V GND
OUT GND RS485
SP6 SP5
+ -

19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
(Option)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

SP4 SP3 SP2 SP1 AUX.


EXC GND V A GND
+24V IN IN POWER

FEATURES: EXTERIOR/CUTOUT DIMENSIONS


5 Digits LED Numeric Display
101-segment LED Bargraph display 144

Wide Range of User Definable Scaling Ratio 10


48 (min.)
Modulized input signal boards available for
different applications
111 21
Optional Output Boards with Isolated Analog Output 45 +0.6
-0

& Relay Output 44.8


85V~265VAC or 18~36VDC Switching Power Supply 138 +1
-0 10
7 (min.)
Support volume adjustment function for non-linear tanks
(optional)

SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 144 (W) x48 (H) x121.5 (D) DIN 3/16 PB-1570-9 99-9 9 9 9
Model PB-1570 Power S---85~265V AC
Supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 01---4~20mA DC with Exc 24V
Power supply Switching Power Supply 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA 04---5V DC with Exc 24V
05---10V DC with Exc 24V
5 Digits, 0.56" 7-Segment red LED 06---20V DC with Exc 24V
07---200V DC with Exc 24V
Display
Input
101 LED Bargraph Display Signal
Display
6 LED set-point indicator A1---2mA AC RMS C1---K2 mA DC with Exc 24V
A2---20mA AC RMS C2---K20 mA DC with Exc 24V
Display Range: -19999 ~ +32767 A3---200mA AC RMS C3---K200 mA DC with Exc 24V
A4---1A AC RMS C4---K1Amp DC
Over Range Display: "1" or "-1" A5---5A AC RMS C5---K5Amp DC

B1---100mV AC RMS D1---K20mV DC with Exc 24V


Range: Refer to Ordering information B2---200mV AC RMS D2---K50mV DC with Exc 24V
B3---2V AC RMS D3---K100mV DC with Exc 24V
Accuracy: 0.1%FS or A1 digit B4---20V AC RMS D4---K200mV DC with Exc 24V
Temperature coefficient: 200ppm/℃ B5---200V AC RMS
Input signal B6---600V AC RMS
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: Contact 0---0 Relays 2---2 Relays 4---4 Relays 6---6 Relays
4 samples/second/channel
Non-Linear 0---Without (Standard)
Function
1---Support 20 points Vessel Conversion
4 relay (up to 6 relay)
Relay contact 3A/250V AC or 5A/30V DC Analog
0---Without
1---0~10V Analog Output
(N.C. / N.O. Jumper selectable) output
2---0/4~20mA

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 9VA
Communication port RS485 (optional) Modbus Protocol EX: PB-1570-S01-4101
Represents: PB-1570 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Storage condition Support Non-Linear Function, without Analog
0~70℃(20 to 90% RH non-condensed)
output, Support RS485 interface.
8
Microprocessor Digit
PM-1430
Display Panel Meter

TERMINAL
ARRANGEMENTS:
RS485 SP4 SP3
Analog Iso
Out GND + - (NC/NO) (COM) (NC/NO) (COM)

11 12 13 14 15 16 17 18 19 20

(Option)

1 2 3 4 5 6 7 8 9 10

EXC GND SIG (NC/NO) (COM) (NC/NO) (COM)


+24V (IN-) (IN+) AUX.
SP2 SP1 POWER

FEATURES: EXTERIOR/CUTOUT DIMENSIONS


4 Digits LED Numeric Display
96
Wide Range of User Definable Scaling Ratio
Modulized input signal boards available for 48 22
different applications (min)

Optional Output Boards with Isolated Analog Output


10 118.5
& Relay Output
45+0.6
85V~265VAC or 18~36VDC Switching Power Supply -0

44.8
Support volume adjustment function for non-linear tanks
92 +0.8
-0 10 (min)
(optional)
IP54 Class front panel

規 格
SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 96 (W) x48 (H) x128.5 (D) DIN 1/8 PM-1430-9 99-9 9 9 9
Model PM-1430 Power S---85~265V AC
supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 01---4~20mA DC with Exc 24V
Power supply Switching Power Supply 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA 04---5V DC with Exc 24V
05---10V DC with Exc 24V
4 Digits, 0.56" 7-Segment red LED 06---20V DC with Exc 24V
07---200V DC with Exc 24V
Display
Input
4 LED set-point indicator signal
Display
Display Range: -1999 ~ +9999 A1---2mA AC RMS C1---K2 mA DC with Exc 24V
A2---20mA AC RMS C2---K20 mA DC with Exc 24V
Over Range Display: "1" or "-1" A3---200mA AC RMS C3---K200 mA DC with Exc 24V
A4---1A AC RMS C4---K1Amp DC
A5---5A AC RMS C5---K5Amp DC

B1---100mV AC RMS D1---K20mV DC with Exc 24V


Range: Refer to Ordering information B2---200mV AC RMS D2---K50mV DC with Exc 24V
B3---2V AC RMS D3---K100mV DC with Exc 24V
Accuracy: 0.1%FS or A1 digit B4---20V AC RMS D4---K200mV DC with Exc 24V
Temperature coefficient: 200ppm/℃ B5---200V AC RMS
Input signal B6---600V AC RMS
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact 0---0 Relays 2---2 Relays 4---4 Relays
4 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
2 or 4 relay
Relay contact 3A/250V AC or 5A/30V DC Analog
0---Without
1---0~10V Analog Output
(N.C. / N.O. Jumper selectable) output
2---0/4~20mA

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 7VA
Communication port RS485 (optional) Modbus Protocol EX: PM-1430-S01-4101
Represents: PM-1430 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Storage condition Support Non-Linear Function, without Analog
0~70℃(20 to 90% RH non-condensed)
output, Support RS485 interface.
9
Microprocessor Digit
PM-2430
Display Panel Meter

TERMINAL
CH2
ARRANGEMENTS:
Analog Analog RS485 SP2 SP1
CH1 Iso CH2
Out GND Out + - (NC/NO) (COM) (NC/NO) (COM)

11 12 13 14 15 16 17 18 19 20

1 2 3 4 5 6 7 8 9 10

EXC GND CH1 CH2 (NC/NO) (COM) (NC/NO) (COM)


+24V (IN-) (IN+) (IN+) AUX.
SP2 SP1 POWER

CH1
FEATURES:
Dual Channel Signal Input EXTERIOR/CUTOUT DIMENSIONS
Dual 4 Digits LED Numeric Display
96
Wide Range of User Definable Scaling Ratio
Modulized input signal boards available for 22
48
different applications (min)

Optional Output Boards with Isolated Analog Output


10 118.5
& Relay Output
45+0.6
-0
85V~265VAC or 18~36VDC Switching Power Supply
44.8
Support volume adjustment function for non-linear tanks
92 +0.8
-0 10 (min)
(optional)
IP54 Class front panel

規規 格格
SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 96 (W) x48 (H) x128.5 (D) DIN 1/8 PM-2430-9 99-9 9 9 9
Model PM-2430 Power S---85~265V AC
supply T---18~36V DC
85 ~ 265V AC or 18~36V DC 1---4~20mA DC with Exc 24V
Power supply Switching Power Supply Input
2---0~20 mA DC with Exc 24V
signal
3---0~200 mA DC with Exc 24V
Power supply for sensor DC24V, 50mA (CH1)
4---5V DC with Exc 24V
5---10V DC with Exc 24V
CH1: 4 Digits, 0.36" 7-Segment red LED 6---20V DC with Exc 24V
7---200V DC with Exc 24V
CH2: 4 Digits, 0.36" 7-Segment green LED
4 LED set-point indicator
Display Input 1---4~20mA DC with Exc 24V
Display Range: -1999 ~ +9999 signal 2---0~20 mA DC with Exc 24V
(CH2) 3---0~200 mA DC with Exc 24V
Over Range Display: "1" or "-1" 4---5V DC with Exc 24V
5---10V DC with Exc 24V
6---20V DC with Exc 24V
7---200V DC with Exc 24V

Range: Refer to Ordering information


Accuracy: 0.1%FS or A1 digit
Temperature coefficient: 200ppm/℃
Input signal
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact
0---0 Relays 2---2 Relays 4---4 Relays 6---6 Relays
2 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
4 relay
Relay contact 3A/250V AC or 5A/30V DC 0---Without
Analog
(N.C. / N.O. Jumper selectable) 5---Dual Analog Output 0~10V
output
6---Dual Analog Output 0/4~20mA

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 7VA
Communication port RS485 (optional) Modbus Protocol EX: PM-2430-S14-4000
Represents: PM-2430 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal CH1: 4~20mA,CH2: 0~5V,
Storage condition 0~70℃(20 to 90% RH non-condensed) 4 relay contact, without Non-Linear Function,
without Analog output.
10
Microprocessor Digit
PM-1530
Display Panel Meter

TERMINAL
ARRANGEMENTS:
RS485 SP4 SP3
Analog Iso
Out GND + - (NC/NO)(COM) (NC/NO) (COM)

11 12 13 14 15 16 17 18 19 20

(Option)

1 2 3 4 5 6 7 8 9 10

EXC GND SIG (NC/NO)(COM)(NC/NO)(COM)


+24V (IN-) (IN+) AUX.
SP2 SP1 POWER

FEATURES: EXTERIOR/CUTOUT DIMENSIONS


5 Digits LED Numeric Display
96
Wide Range of User Definable Scaling Ratio
Modulized input signal boards available for 48 22
different applications (min)

Optional Output Boards with Isolated Analog Output


10 118.5
& Relay Output
45+0.6
85V~265VAC or 18~36VDC Switching Power Supply -0

44.8
Support volume adjustment function for non-linear tanks 92 +0.8 10 (min)
-0
(optional)
IP54 Class front panel

規 格
SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 96 (W) x48 (H) x128.5 (D) DIN 1/8 PM-1530-9 99-9 9 9 9
Model PM-1530 Power S---85~265V AC
Supply T---18~36V DC

01---4~20mA DC with Exc 24V


Power supply 20~250 Vac / Vdc 50/60Hz 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
04---5V DC with Exc 24V
05---10V DC with Exc 24V
5 Digits, 0.56" 7-Segment red LED 06---20V DC with Exc 24V
07---200V DC with Exc 24V
Display
Input
4 LED set-point indicator signal
Display
Display Range: -19999 ~ +99999 A1---2mA AC RMS C1---K2 mA DC with Exc 24V
A2---20mA AC RMS C2---K20 mA DC with Exc 24V
Over Range Display: "1" or "-1" A3---200mA AC RMS C3---K200 mA DC with Exc 24V
A4---1A AC RMS C4---K1Amp DC
A5---5A AC RMS C5---K5Amp DC

B1---100mV AC RMS D1---K20mV DC with Exc 24V


Range: Refer to Ordering information B2---200mV AC RMS D2---K50mV DC with Exc 24V
B3---2V AC RMS D3---K100mV DC with Exc 24V
Accuracy: 0.1%FS or A1 digit B4---20V AC RMS D4---K200mV DC with Exc 24V
Temperature coefficient: 200ppm/℃ B5---200V AC RMS
Input signal B6---600V AC RMS
ADC Resolution: 4-1/2 digit
Relay
Sampling Rate: contact 0---0 Relays 2---2 Relays 4---4 Relays
24 samples/second/channel
Non-Linear 0---Without (Standard)
function 1---Support 20 points Vessel Conversion
2 or 4 relay
Relay contact 3A/250V AC or 5A/30V DC 0---Without
Analog
(N.C. / N.O. Jumper selectable) 1---0~10V Analog Output
output
2---0/4~20mA

Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 7VA
Communication port RS485 (optional) Modbus Protocol EX: PM-1530-S01-4101
Represents: PM-1530 Model, Power supply 85~265V AC,
Operating condition 0~50℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Storage condition Support Non-Linear Function, without Analog
0~70℃(20 to 90% RH non-condensed)
output, Support RS485 interface.
11
Microprocessor Digit
PM-1X30-W
Display Panel Meter

TERMINAL
ARRANGEMENTS:
Isolated
Output
Analog RS485 D1
+24V GND CH1 GND
Input (Out) (Out) - -
+ +
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NO COM NC NO COM NC NO COM NC NO COM NC


AUX.
SP1 SP2 SP 3 SP4 POWER

FEATURES: EXTERIOR/CUTOUT DIMENSIONS


5 Digits LED Numeric Display
Wide Range of User Definable Scaling Ratio
96
Modulized input signal boards available for
different applications 22
(min)
48
Optional Output Boards with Isolated Analog Output
& Relay Output
20~250Vac/Vdc 50/60Hz Switching Power Supply 10 118.5
45+0.6
-0

Support volume adjustment function for non-linear tanks


(optional) 44.8
92 +0.8
-0 10 (min)

IP54 Class front panel

規規 格格
SPECIFICATIONS
ORDERING INFORMATION:
Dimension (mm) 96 (W) x48 (H) x128.5 (D) DIN 1/8 P M - 1 9 3 0 - W 99 - 9 9 9 9 9
Model PM-1 9 30-W Display
4 : 4 digit
5 : 5 digit
Power
20~250 Vac-dc, 50~60Hz
Power supply supply
20~250 Vac / Vdc 50/60Hz
01---4~20mA DC with Exc 24V
Power supply for sensor 02---0~20 mA DC with Exc 24V
03---0~200 mA DC with Exc 24V
04---0~5V DC with Exc 24V
05---0~10V DC with Exc 24V
5 Digits, 0.56" 7-Segment red LED 06---0~20V DC with Exc 24V
07---0~200V DC with Exc 24V
Display Input
signal A1---0~2mA AC RMS C1---0~K2 mA DC with Exc 24V
Display 4 LED set-point indicator A2---0~20mA AC RMS C2---0~K20 mA DC with Exc 24V
A3---0~200mA AC RMS C3---0~K200 mA DC with Exc 24V
Display Range: -19999 ~ +99999 A4---0~1A AC RMS C4---0~K1Amp DC
A5---0~5A AC RMS C5---0~K5Amp DC
Over Range Display: "1" or "-1" D1---0~K20mV DC with Exc 24V
B1---0~100mV AC RMS
B2---0~200mV AC RMS D2---0~K50mV DC with Exc 24V
B3---0~2V AC RMS D3---0~K100mV DC with Exc 24V
B4---0~20V AC RMS D4---0~K200mV DC with Exc 24V 可 程 式 數 字 顯 示 控 制 表
Range: Refer to Ordering information B5---0~200V AC RMS E1---5/10/20/50/100/200mV/
B6---0~600V AC RMS V DC (Option) with Exc 24V
Accuracy: 0.1%FS or A1 digit B7---0~1000V AC RMS E2---1/2/5/10/20mV/V DC (Option)
Temperature coefficient: 200ppm/℃ with ISO 10V
Input signal E3---1/2/10/20/40mV/V DC (Option)
ADC Resolution: 4-1/2 digit with ISO 5V
Sampling Rate:
F1----TC(K、J、E、N、T) & RTD (PT100、JPT100)
24 samples/second/channel F2----TC(K、J、R、S、B、E、N、T) & RTD (PT100、JPT100)
Relay
0~4:0~4 Relays
contact
Non-Linear 0---Without (Standard)
Relay contact 4 relay function 1---Support 20 points Vessel Conversion
3A/250V AC or 5A/30V DC
0---Without
Analog
1---0~10V Analog Output
output
2---0/4~20mA
Analog output 4~20mA, 0~20mA, 2~10V and 0~10V (optional) Communi- 0---Without
cation port 1---Support RS485 interface
Power comsumption Less then 7VA
0 : Without
Digital input
1 : DI
Communication port RS485 (optional) Modbus Protocol
Operating condition 0~50℃(20 to 90% RH non-condensed) EX: PM-1530-S01-41011
Represents: PM-1530 Model, Power supply 85~265V AC,
Storage condition 0~70℃(20 to 90% RH non-condensed) Analog input signal 4~20mA, 4 relay contact,
Support Non-Linear Function, without Analog
12 output, Support RS485 interface.
PB DC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Dual Channel Signal Input Module: Single Channel Signal Input Module:
(for PB-2471) (for PB-1471, PB-1470, PB-1570)
11: 4~20mA DC with Excitation +24V 01: 4~20mA DC with Excitation +24V
EXC 24V EXC 24V
PIN 1 PIN 1
PIN 2 PIN 2
+ - + - Common PIN 3 + - Common PIN 3
PIN 4 PIN 4
200mA

200mA
20mA
200V

20mA
200V
10V

10V
20V

20V
5V

5V
CH1 Input PIN 5 CH1 Input PIN 5
PIN 6 PIN 6
PIN 7 PIN 7
CH2 Input PIN 8 PMB-0641 PIN 8 PMB-0641

22: 0~20mA DC with Excitation +24V 02: 0~20mA DC with Excitation +24V
EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
PIN 3 PIN 3
CH1 Iinput PIN 4 CH1 Input PIN 4

200mA
200mA

DC mA

20mA
200V

10V
20V
20mA
200V

5V
10V
20V

5V

CH1 GND PIN 5 Common PIN 5


PIN 6 PIN 6
CH2 Iinput PIN 7 PIN 7
CH2 GND PIN 8 PMB-0641 PIN 8 PMB-0640

33: 0~200mA DC with Excitation +24V 03: 0~200mA DC with Excitation +24V
EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
PIN 3 PIN 3
CH1 Iinput PIN 4 CH1 Input PIN 4
200mA

200mA
20mA
200V

10V
20V

DC mA

20mA
200V

10V
5V

20V

5V
CH1 GND PIN 5 Common PIN 5
PIN 6 PIN 6
CH2 Iinput PIN 7 PIN 7
CH2 GND PIN 8 PMB-0641 PIN 8 PMB-0640

44:A5V DC with Excitation +24V 04:A5V DC with Excitation +24V


EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
CH1 Vinput PIN 3 CH1 Vinput PIN 3
PIN 4 DC V PIN 4
200mA
200mA

20mA
200V

10V
20mA
200V

20V
10V
20V

5V
5V

CH1 GND PIN 5 Common PIN 5


CH2 Vinput PIN 6 PIN 6
PIN 7 PIN 7
CH2 GND PIN 8
PMB-0641 PIN 8 PMB-0640

55:A10V DC with Excitation +24V 05:A10V DC with Excitation +24V


EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
CH1 Vinput PIN 3 CH1 Vinput PIN 3
PIN 4 DC V PIN 4
200mA

200mA
20mA
200V

20mA
200V
10V

10V
20V

20V
5V

5V

CH1 GND PIN 5 Common PIN 5


CH2 Vinput PIN 6 PIN 6
PIN 7 PIN 7
CH2 GND PIN 8 PMB-0641 PIN 8 PMB-0640

66:A20V DC with Excitation +24V 06:A20V DC with Excitation +24V


EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
CH1 Vinput PIN 3 CH1 Vinput PIN 3
PIN 4 DC V PIN 4
200mA

200mA
20mA
200V

10V
20V

20mA
200V

10V
5V

20V

5V

CH1 GND PIN 5 Common PIN 5


CH2 Vinput PIN 6 PIN 6
PIN 7 PIN 7
CH2 GND PIN 8 PMB-0641 PIN 8
PMB-0640

77: A200V DC with Excitation +24V 07: A200V DC with Excitation +24V
EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
CH1 Vinput PIN 3 CH1 Vinput PIN 3
PIN 4 DC V PIN 4
200mA
200mA

20mA
200V

10V
20V
20mA
200V

10V

5V
20V

5V

CH1 GND PIN 5 Common PIN 5


CH2 Vinput PIN 6 PIN 6
PIN 7 PIN 7
PMB-0641 PMB-0640
CH2 GND PIN 8 13 PIN 8
PB AC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Single Channel Signal Input Module: (for PB-1471, PB-1470, PB-1570)

A1: 2mA AC Scaled RMS B1: 100mV AC Scaled RMS


PIN 1 PIN 1
PIN 2 PIN 2
PIN 3 Vin ( v ) PIN 3
Iin ( v ) PIN 4 AC mV PIN 4
AC mA
Iin (w) PIN 5 Vin (w) PIN 5
200mA
20mA
2mA

PIN 6 PIN 6

J3
PIN 7 PIN 7
PIN 8 PMB-0672 PIN 8 PMB-0675

A2: 20mA AC Scaled RMS B2: 200mV AC Scaled RMS


PIN 1 PIN 1
PIN 2 PIN 2
PIN 3 Vin ( v ) PIN 3
Iin ( v ) PIN 4 AC mV PIN 4
AC mA
Iin (w) PIN 5 Vin (w) PIN 5
200mA
20mA
2mA

PIN 6 PIN 6
PIN 7 PIN 7
PMB-0672 PMB-0671

2V

200mV
PIN 8 PIN 8

A3: 200mA AC Scaled RMS B3: 2V AC Scaled RMS


PIN 1 PIN 1
PIN 2 PIN 2
PIN 3 Vin ( v ) PIN 3
Iin ( v ) PIN 4 AC V PIN 4
AC mA
Iin (w) PIN 5 Vin (w) PIN 5
200mA
20mA
2mA

PIN 6 PIN 6
PIN 7 PIN 7
PMB-0672 PMB-0671
2V

200mV
PIN 8 PIN 8

A4: 1Amp AC Scaled RMS B4: 20V AC Scaled RMS


PIN 1
PIN 2
Vin ( v ) PIN 3
AC V PIN 4
PIN 1 20V

PIN 2
Vin (w) PIN 5 200V
600V
PIN 6
PIN 3
Secondary PIN 7
PIN 4 PMB-0670
1A PIN 8
PIN 5
Current PIN 6
J3

PIN 7
AC current

PIN 8 PMB-0674
B5: 200V ACScaled RMS
Primary

PIN 1
PIN 2
CH1 Vin ( v ) PIN 3
AC V PIN 4 20V

A5: 5 Amp AC Scaled RMS CH2 Vin (w) PIN 5


200V
600V

PIN 6
PIN 7
PIN 8 PMB-0670

PIN 1
PIN 2
B6: 600V AC Scaled RMS
PIN 3
Secondary
PIN 4 PIN 1
5A PIN 5 PIN 2
Current PIN 6 CH1 Vin ( v )
J3

PIN 3
PIN 7 AC V PIN 4 20V
AC current

PMB-0673
CH2 Vin (w)
200V
PIN 8 PIN 5 600V
Primary

PIN 6
PIN 7
PIN 8 PMB-0670

14
PB DC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Single Channel Signal Input Module:


(for PB-1471, PB-1470, PB-1570)
C1: 2mA DC with Excitation +24V D1: 20 mV DC with Excitation +24V
EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
PIN 3 Input PIN 3
Input PIN 4 DC mV PIN 4
DC mA

100mV
200mV
20mV
50mV
Common PIN 5 Common PIN 5
200mA
20mA
2mA

PIN 6 PIN 6
PIN 7 PIN 7
PIN 8 PMB-0681 PIN 8 PMB-0680

C2: 20mA DC with Excitation +24V D2: 50 mV DC with Excitation +24V


EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
PIN 3 Input PIN 3
Input PIN 4 DC mV PIN 4

100mV
200mV
DC mA

20mV
50mV
Common PIN 5 Common PIN 5
200mA
20mA
2mA

PIN 6 PIN 6
PIN 7 PIN 7
PIN 8 PMB-0681 PIN 8 PMB-0680

C3: 200mA DC with Excitation +24V D3: 100 mV DC with Excitation +24V
EXC 24V PIN 1 EXC 24V PIN 1
Common PIN 2 Common PIN 2
PIN 3 Input PIN 3
Input PIN 4 DC mV PIN 4

100mV
200mV
DC mA

20mV
50mV
Common PIN 5 Common PIN 5
200mA
20mA
2mA

PIN 6 PIN 6
PIN 7 PIN 7
PIN 8 PMB-0681 PIN 8 PMB-0680

C4: 1A DC D4: 200 mV DC with Excitation +24V


EXC 24V PIN 1
Common PIN 2
Input PIN 3
DC mV PIN 4
100mV
200mV
20mV
50mV

PIN 1 Common PIN 5


PIN 2 PIN 6
PIN 3
Secondary PIN 7
PIN 4 PIN 8 PMB-0680
1A PIN 5
Current PIN 6
J3

PIN 7
AC current

PIN 8 PMB-0683
Primary

Fully User Scalable

C5: 5A DC

PIN 1
PIN 2
PIN 3
Secondary
PIN 4
5A PIN 5
Current PIN 6
J3

PIN 7
AC current

PIN 8 PMB-0682
Primary

Fully User Scalable

15
PM DC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Dual Channel Signal Input Module: (for PB-2430) Single Channel Signal Input Module:
(for PB-1430, PB-1530)
11: 4~20 mA DC with Excitation +24V 01:4~20mA DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common

I Ch1 V
PIN 2 Common PIN 2
200mA
20mA

DC mA

200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V
CH1 Input Input
I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

22: 200 mA DC with Excitation +24V 02: 20mA DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common

I Ch1 V
PIN 2 Common PIN 2
200mA
20mA

DC mA

200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V
CH1 Input Input
I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

33: 200 mA DC with Excitation +24V 03: 200mA DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common

I Ch1 V
PIN 2 Common PIN 2
200mA
20mA

DC mA

200mA
200V

20mA
20V

200V
5V

20V
10V
5V
CH1 Input Input
I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

44: 5V DC with Excitation +24V 04: 5V DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common PIN 2 Common PIN 2


200mA
20mA

DC V
200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V

CH1 Input Input


I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

55: 10V DC with Excitation +24V 05: 10V DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common
I Ch1 V

PIN 2 Common PIN 2


200mA
20mA

DC V
200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V

CH1 Input Input


I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

66: 20V DC with Excitation +24V 06: 20V DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common
I Ch1 V

PIN 2 Common PIN 2


200mA
20mA

DC V
200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V

CH1 Input Input


I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

77: 20V DC with Excitation +24V 07: 200V DC with Excitation +24V

EXC +24V PIN 1 PMB-0031 EXC +24V PIN 1 PMB-0030


I Ch1 V

Common
I Ch1 V

PIN 2 Common PIN 2


200mA
20mA

DC V
200mA
200V

20mA
20V
10V

200V
5V

20V
10V
5V

CH1 Input Input


I Ch2 V

PIN 3 PIN 3

CH2 Input PIN 4 PIN 4

16
PM AC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the correct
jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input signals,
20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Single Channel Signal Input Module:


(for PM-1430, PM-1530)

A1: 2mA AC Scaled RMS B1: 100mV AC Scaled RMS

PIN 1 PMB-0056 PIN 1


PMB-0059

Iin ( v ) PIN 2 Vin ( v ) PIN 2

AC mA PIN 3 AC mV PIN 3
200mA
20mA
2mA

J3
Iin (w) PIN 4 Vin (w) PIN 4

A2: 20mA AC Scaled RMS B2: 200mV AC Scaled RMS

PIN 1 PMB-0056 PIN 1 PMB-0055

Iin ( v ) PIN 2 Vin ( v ) PIN 2

AC mA PIN 3 AC mV PIN 3
200mA
20mA
2mA

Iin (w) PIN 4 Vin (w) PIN 4

2V

200mV
A3: 200mA AC Scaled RMS B3: 2V AC Scaled RMS

PIN 1 PMB-0056 PIN 1 PMB-0055

Iin ( v ) PIN 2 Vin ( v ) PIN 2

AC mA PIN 3 AC V PIN 3
200mA
20mA
2mA

Iin (w) PIN 4 Vin (w) PIN 4


2V

200mV

A4: 1Amp AC Scaled RMS B4: 20V AC Scaled RMS

PIN 1 PMB-0054

PIN 1 PMB-0058
Vin ( v ) PIN 2
20V

PIN 2 200V
AC V PIN 3 600V

1A Secondary PIN 3
Vin (w) PIN 4
J3

Current PIN 4
AC current
Primary

B5: 200V ACScaled RMS

PIN 1 PMB-0054

Vin ( v ) PIN 2
20V

A5: 5 Amp AC Scaled RMS AC V PIN 3


200V
600V

Vin (w) PIN 4

PIN 1 PMB-0057

PIN 2
B6: 600V AC Scaled RMS
Secondary PIN 3
5A
J3

PIN 4 PIN 1 PMB-0054


Current
AC current

Vin ( v ) PIN 2
Primary

20V
200V
AC V PIN 3 600V

Vin (w) PIN 4

17
PM DC SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Single Channel Signal Input Module:


(for PM-1430, PM-1530)

C1: 2mA DC with Excitation +24V D1: 20 mV DC with Excitation +24V

PIN 1
PMB-0051 PMB-0050
EXC 24V EXC 24V PIN 1

Common PIN 2 Common PIN 2

100mV
200mV
20mV
50mV
DC mA DC mV
Input PIN 3 Input PIN 3
200mA
20mA
2mA

PIN 4 PIN 4

C2: 20mA DC with Excitation +24V D2: 50 mV DC with Excitation +24V

EXC 24V PIN 1 PMB-0051 PIN 1


PMB-0050
EXC 24V
Common PIN 2 Common PIN 2

100mV
200mV
DC mA

20mV
50mV
DC mV
Input PIN 3 Input PIN 3
200mA
20mA
2mA

PIN 4 PIN 4

C3: 200mA DC with Excitation +24V D3: 100 mV DC with Excitation +24V

EXC 24V PIN 1 PMB-0051 EXC 24V PIN 1 PMB-0050

Common PIN 2 Common PIN 2

100mV
200mV
DC mA

20mV
50mV
DC mV
Input PIN 3 Input PIN 3
200mA
20mA
2mA

PIN 4 PIN 4

C4: 1A DC D4: 200 mV DC with Excitation +24V

EXC 24V PIN 1 PMB-0050


PIN 1 PMB-0053
Common PIN 2
100mV
200mV
20mV
50mV

PIN 2
DC mV
Input PIN 3
Secondary PIN 3
1A PIN 4
J3

CT
PIN 4
DC current
Primary

Fully User Scalable

C5: 5A DC

PIN 1 PMB-0052

PIN 2

Secondary PIN 3
5A
J3

CT
PIN 4
DC current
Primary

Fully User Scalable

18
PM -1X30-W DC SIGNAL INPUT MODULE(0)

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Signal Input Module:


01: 4~20mA DC with Excitation +24V 05: 0~10V DC with Excitation +24V

17
PMB-0130 17
PMB-0130
EXC 24V EXC 24V
EXC 18 EXC 18
I Ch1 V

I Ch1 V

200mA
200mA
20mA

20mA
200V

10V
200V

20V

5V
20V
10V
5V

I n (w) 19 I n (w) 19
DC mA DC V
In (v) 20 In (v) 20

21 21

02: 0~20mA DC with Excitation +24V 06: 0~20V DC with Excitation +24V

17
PMB-0130 17
PMB-0130
EXC 24V EXC 24V
EXC 18 EXC 18
I Ch1 V

I Ch1 V

200mA
200mA

20mA
200V

10V
20mA

20V
200V

5V
20V
10V
5V

I n (w) 19 I n (w) 19
DC mA DC V
In (v) 20 In (v) 20

21 21

03: 0~200mA DC with Excitation +24V 07: 0~200V DC with Excitation +24V

PMB-0130 PMB-0130
EXC 24V 17 EXC 24V 17

EXC 18 EXC 18
I Ch1 V

I Ch1 V
200mA
20mA
200V

200mA
20V
10V

20mA
200V

10V
5V

20V

5V

I n (w) 19 I n (w) 19
DC mA DC V
In (v) 20 In (v) 20

21 21

04: 0~5V DC with Excitation +24V

PMB-0130
EXC 24V 17

EXC 18
I Ch1 V

200mA
20mA
200V

10V
20V

5V

I n (w) 19
DC V
In (v) 20

21

19
PM -1X30-W AC SIGNAL INPUT MODULE(AB)

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Signal Input Module:


A1: 0~2mA AC RMS B1: 0~100mV AC RMS

17 PMB-0152
17
PMB-0150
18
18 AC V

100mV
200mV
19

2V
200mA
20mA
2mA

AC mA 19 20
20 21
21

B2: 0~200mV AC RMS

A2: 0~20mA AC RMS PMB-0152


17

18
AC V 19

100mV
200mV
2V
17
PMB-0150
20
18 21
200mA
20mA
2mA

AC mA 19
20 B3: 0~2V AC RMS
21

17 PMB-0152

18

100mV
200mV
2V
AC V 19
A3: 0~200mA AC RMS 20

21

PMB-0150
17 B4: 0~20V AC RMS
18
PMB-0153
200mA
20mA
2mA

17
AC mA 19
18
20
AC V 19
21
1000V
200V
600V
20V

20

21

B5: 0~200V AC RMS


A4: 0~1A AC RMS
17
PMB-0153

18

17
PMB-0151 AC V 19
20
1000V
200V
600V
20V

18
21
AC A 19
20

21
B6: 0~600V AC RMS

17
PMB-0153

A5: 0~5A AC RMS 18


AC V 19
1000V
200V
600V
20V

20

21
17 PMB-0151

18
AC A 19 B7: 0~1000V AC RMS
20
17
PMB-0153
21
18
AC V 19
20
1000V
200V
600V
20V

21

20
PM -1X30-W DC SIGNAL INPUT MODULE(CDE)

This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the
correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input
signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup.

Signal Input Module:


C1: 0~K2mA DC with Excitation +24V D1: 0~K20mV DC with Excitation +24V

PMB-0134
PMB-0131 EXC 24V 17
EXC 24V 17
EXC 18
EXC 18

100mV
200mV
20mV
50mV
I n (w) 19
200mA
20mA
2mA

I n (w) 19 DC mV
DC mA In (v) 20
In (v) 20
21
21

D2: 0~K50mV DC with Excitation +24V


C2: 0~K20mA DC with Excitation +24V PMB-0134
EXC 24V 17

EXC 18

100mV
200mV
20mV
50mV
PMB-0131 I n (w) 19
EXC 24V 17
DC mV
EXC 18 In (v) 20

21
I n (w) 19
200mA
20mA
2mA

DC mA
In (v) 20

21 D3: 0~K100mV DC with Excitation +24V

EXC 24V 17 PMB-0134

EXC 18

100mV
200mV
20mV
50mV
I n (w) 19
C3: 0~K200mA DC with Excitation +24V DC mV
In (v) 20

21

EXC 24V 17 PMB-0131

EXC 18 D4: 0~K200mA DC with Excitation +24V


I n (w) 19
200mA
20mA
2mA

DC mA
In (v) 20
EXC 24V 17
PMB-0134
21
EXC 18
100mV
200mV
20mV
50mV

I n (w) 19
DC mV
In (v) 20

21

C4: 0~K1A DC E1: 5/10/20/50/100/200mV DC (Option) with Excitation +24V


EXC 24V 17 PMB-0133
PMB-0132
EXC 24V 17 EXC 18
200mA
10mV
20mV

20mA
200V
5mV

EXC 18 I n (w) 19
DC mV
I n (w) 19
In (v) 20
DC A
20 21
In (v) 21

E2: 1/2/5/10/20mV/V (Option) with ISO 10V

ISO 10V 17 PMB-0133


C5: 0~K5A DC ISO 18
200mA
10mV
20mV

20mA
200V
5mV

I n (w) 19
DC mV/V
EXC 24V 17
PMB-0132 In (v) 20

21
EXC 18

I n (w) 19
DC A
20 E3: 1/2/10/20/40mV/V (Option) with ISO 5V
In (v) 21

ISO 5V 17 PMB-0133

ISO 18
200mA
10mV
20mV

20mA
200V
5mV

I n (w) 19
DC mA
In (v) 20

21

21
PM-1X30-W TEMPERATURE SIGNAL INPUT MODULE

This section will elaborate how to adapt to different input signals in the PM series
panel meter, by using the correct jumper and using iSEL command. Panel meter
series can accommodate 6 types of conventional input signals, 20mA, 200mA, 5V,
10V, 20V, 200V, please refer below for setup.
Signal Input Module:

F1: TC (K、J、E、N、T) & RTD (Pt100、JPT100)

17
PMB-0153

18
A 19
b 20

B TC 21
RTD

F2: TC (K、J、E、N、T、R、S、B) & RTD (PT100、JPT100)

17 PMB-0153

18

A 19

b 20

B TC 21
RTD

22
Global Network
Germany
China

U.S.
Taiwan U.S.

Singapore

Asia North America Europe


Taiwan California, U.S. Germany
FINETEK CO., LTD. - Taipei Head Quarter APLUS FINETEK SENSOR INC. - US Office FineTeK GmbH - Germany Office
No.16, Tzuchiang St., Tucheng Industrial Park 355 S. Lemon Ave, Suite D, Walnut, Frankfurter Str. 62, OG D-65428
New Taipei City 236, Taiwan CA 91789 Ruesselsheim, Germany
TEL: 886-2-2269-6789 TEL: 1 909 598 2488 TEL: +49-(0)6142-17608-0
FAX: 886-2-2268-6682 FAX: 1 909 598 3188 FAX: +49-(0)6142-17608-20
EMAIL: info@fine-tek.com EMAIL: info@aplusfine.com EMAIL: info@fine-tek.de

FINETEK CO., LTD. - I-Lan Factory Illinois, U.S.


TEL: 886-3-990-9669 APLUS FINETEK SENSOR INC.
FAX: 886-3-9909659 TEL: 1 815 632-3132
FAX: 1 815 716 8464
FINETEK CO., LTD. - Taichung Brance EMAIL: info@aplusfine.com
TEL: 886-4-2337-0825
FAX: 886-4-2337-0836

FINETEK CO., LTD. - Kaohsiung Branch


TEL: 886-7-333-6968
FAX: 886-7-536-8758

China
FINE AUTOMATION CO., LTD. - Shanghai Factory
No.451 DuHui Rd, MinHang District, Shanghai,
China 201109
TEL: 86-21-6490-7260
FAX: 86-21-6490-7276
EMAIL: info.sh@fine-tek.com Distributor:

Singapore
FINETEK PTE LTD. - Singapore Office
No. 60 Kaki Bukit Place, #07-06 Eunos
Techpark 2 Lobby B, Singapore 415979
TEL: 65-6452-6340
FAX: 65-6734-1878
EMAIL: info.sg@fine-tek.com

08-PB-B1-EP, 01/21/2013