1. SUMMARIZATION ...............................................................1
BKJ2 MODEL 2. WORK ELEMENT ................................................................2
3. MASTER TECHONOLOGIC PARAMETER .....................3
4. DIMENSIONS AND WEIGHT .............................................3
5. PANEL INTRODUCTION ....................................................4
MARINE MASTER-SLAVE CLOCK 6. METHOD OF FIXING, SPAN AND ADJUSTING .............4
7. OPERATION .........................................................................4
8. OPERATION OF KEY AND SWITCH................................5
9. ITEMS AND METHOD IN NATURAL MAINTENANCE ..5
INSTRUCTION MANUAL 10. REQUST IN TRANSPORTATION AND STORAGE ........5
11. REGARDABLE ITEM...........................................................5
POWER MASTER
1. MASTER CLOCK (FIGURE 2. SHOWS IT) CLOCK
CIRCUIT
Controlled by 89C51 single chip, the master clock memory
data, operate coding, produce pulse-signal, transmit to slave
clocks through RS422 interface, check slave clocks. At the same FIGURE 3 SLAVE ELEMENT
time, master clock accepts standard time from standard time Slave clocks rely on quartz crystal oscillator in itself, through
accept units and check the precision itself. RS422 interface, connect with cable of master clock directly.
Accepting standard time signal from master clock, slave clocks
check their precision, clear up the error automatically, display the
2
uniform time. When they can’t accept standard time signal, slave 4. DIMENSIONS AND WEIGHT
clocks can work depending on it’s precision.
Master clock and each slave-clock Dimensions and weight
There are “ADV” and “REV” methods in slave clock. They can
Dimensions
chase time automatically, when accepting standard time signal, Weight
NO. Name Width (mm) × height Remark
adjust fingers to standard time in short time with the shortest (Kg)
(mm) × depth (mm)
distance. When it run solely, you can adjust time through keyboard.
1 Master clock 460×310×120 15 BKJ2/A
3. MASTER TECHONOLOGIC PARAMETER ( wall-mounted)
-7
1. master clock frequency stabilization : 1×10 2 Master clock 440×340×120 15 BKJ2/A
2. slave clock frequency stabilization : 1×10-6 (flush-mounted)
3. work time: work continually 3 circular slave clock Ф210×60 2 BKJ2/B2
4. slave clock independent Working accuracy: ≤ 0.5 s/d
4 circular slave clock Ф180×60 3.5 BKJ2/B3
5. slave clock is synchronized with the master clock seconds,
synchronization error ≤ 1 5 Centralized control table Ф180×60 3.5 BKJ2/B4
6. master clock work voltage:AC220V/110V±10% slave clock
50/60Hz±5%
6 Double-face slave clock 310×100 3.3 BKJ2/B5
7. DC24V±25% Electrical wires are insulated.
8. work electrical current: 0.5A 7
decorative slave clock 340×300×68 3 BKJ2/B6
3
5. PANEL INTRODUCTION 6. METHOD OF FIXING, SPAN AND ADJUSTING
FRONT PANEL IN BKJ2 MODEL MARINE MASTER-SLAVE CLOCK 1. fixing
(1)The fixing manner of master clock is hanged or flush type. Fix
the clock using fore M4 screws.
(2) The method of BKJ2/B2、B6、B5、B9、B12 etc slave clocks
are same to master clock. Fix them using three or four screws.
Refer to drawing when fixing.
(3)BKJ2/B3(4) slave clock are inlay type. Fix in the commodious
plane, refer to the drawing when fixing.
2. the method of connected with exterior
(1)master clock:
Connect with slave clock by four-wire cable. “T+” in export of
master clock correspond with that in slave clock. “T-” ,“24V”,“VSS”
are same.
Master clock has many exports, try your best to distribute
averagely. Require: Connect exactly according to the marks.
1. standard (master clock) finger clock (2)parallel connect all slave clocks through four-wire cable.
2. local (slave clock) finger clock Require: Connected wire must be absolutely right, especially
3. key to adjust master clock time power cable must be connected rightly.
4. key to adjust slave clock time 7. OPERATION
5. standard (master clock) time display window
(1)First, check the cable is OK or NOT, and the cable between
6. local (slave clock) time display window
master clock with slave clock is correct or not.
7. master clock power(DC24V)
(2)Power cable of AC220V Connect correctly, DC24V also,
8. slave clock power(DC24V)
power switch is set to “OFF”.
9. total power(AC220V)
(3)Turn on total power switch , at this time neon light should be
10. key to stop second
bright. Two time display windows show info. Slave click begin to
4
work. 9. ITEMS AND METHOD IN NATURAL MAINTENANCE
(4)At this time, if two fingers of master clock and slave clock are
not on “12” o’clock, they will run there automatically. Keep the equipment in the system dry and clean.
Adjust right key, check the communication of slave clocks. 10. REQUST IN TRANSPORTATION AND STORAGE
8. OPERATION OF KEY AND SWITCH Conveyance manner: Road or railway
1. key in master clock Note: Convey carefully, not knock.
Key in mater clock can be used to adjust time of master clock. require of storage in Short time: Dampproof and dustproof
Press the “HOUR”、 “MIN” key, hour、minute should be adjusted, 11. REGARDABLE ITEM
press once, the amount of hour and minute will increase or
Warning: Cable between equipment in the system must be
decrease one correspondingly. Press the “+/-” key, can change the
correct, especially power cable must be conformed to be right,
amount of the hour and minute increasing or decreasing. Press the
otherwise the equipment will be destroyed.
“SEC” key, second will reset to work from original position.
2. key in slave clock 12. SERVICE
Key in slave clock can be used to adjust time of slave clock.. The Warranty period of 12 months, during the warranty period, the
function of the “HOUR”、“MIN”、 “+/-” key are same to which in device itself causes failure, the factory is responsible for all free
master clock.. maintenance, if a user operating error or due to force majeure, the
3. power switch in master clock factory cost price given to maintenance. After the warranty expires,
Power supply in master clock is DC24V. It is provided by two the factory with the most favorable price to provide users with
pieces of circuits, one comes from DC24V in alternating current maintenance and accessories.
module, the other comes from DC24V provided by storage battery.
4. power switch in slave clock
Power supply in slave clock is same to what in master clock. It is
also provided by two pieces of circuits, one comes from DC24V in
alternating current module, the other comes from DC24V provided
by storage battery.
5
Yantai Horology Research Institute CO.,LTD
Address:76 Chaoyang Street Yantai, Shandong, China
Postcode:264001
Tel:0086-0535-6226030
FAX: 0086-0535-6226030