PC Sensor: Warning

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Chapter

4Ia PC Sensor
Introduction
● Warning
The PC sensor is a precision instrument. Failure to follow the guidelines below could result in malfunction or
failure.
- Do not disassemble.
- Do not touch the detection shaft.
- Handle with care because the PC sensor is extremely fragile and very vulnerable to strong impact.

● Yarn incompatible with PC sensor


If the following yarn is used for winding, it may cause damage or faulty detection.
We recommend following the procedure described later to remove the sensor and to perform the winding
operation in the tension manager section.

- Dirty yarn contaminated with such contaminants as grease that could significantly smear the detection 1
Sec
shaft.
- Yarn that could wear down the ceramic guide and the detection shaft that make up the yarn path.

Sec 1 Adjustment Standard


1-1 VOS Settings
The VOS settings are listed below. Change the setting conditions when necessary.
PC Sensor Select "Without" or "With"
Tension Control System Select from: Tension Mgr / Tension Fdbk / Fix Appld Tnsn

* If the PC sensor is turned OFF, the tension feedback cannot be selected.

1 Doc No. P250


Chapter 4Ia Version 120401
Sec 2 Maintenance
2-1 Cleaning
If any cotton fly or waste is stuck to the detection shaft or yarn guide, remove it gently using a cloth or cotton
swab moistened with water, or water diluted with mild detergent.

- Do not apply too much pressure on the detection shaft when cleaning.
- Cleaning methods which place any load on the detection shaft, such as wiping with a
cloth or blowing with an air blast from close range, can damage the PC sensor.
- Do not use alcohol based agents (thinner, benzine, etc.).

2-2 Damage & Failure


If part of the PC sensor is damaged or has failed, replace the entire PC sensor unit.
2
Sec
Fixing bolt (M5)

Detection
shaft

Air hose insertion hole

Removing & Attaching the PC Sensor


1. Remove the PC tensor from the winding unit while the PC sensor is attached.
2. After removing the (M5) bolt shown above and the air hose, remove the PC sensor from the PC
tensor.
* To attach the PC sensor, perform the removal procedure in reverse order.

Attaching and removing the PC sensor while PC tensor is attached to the winding unit may
cause the air hose insertion hole to break.

When Using the Winding Unit without the PC Sensor Attached


Cover the 2 places indicated below with the special parts provided.

Cap

Joint

Sensor connection for the casing Air pipe connected to the PC sensor

2 Doc No. P250


Chapter 4Ia Version 150501

You might also like