Construction and Building Security Raised Floor - Compressed

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

Construction and Building Security

week 6

Raised floor installation


False ceiling
Raised floors
False ceiling Raised floors

The raised floor is the false ceiling upside down



What are raised floor system?
Raised floor systems, also known as access floors, are an
elevated structural floor that is stabilized over a solid substrate,
typically a concrete slab.
• Covering And Finishing Solution .
• Solution for the electric and services that need channels in the
wall and slap.
• Easy maintain by only removing the tile .
• Prefabricated solution which coast less while insulation
What are the types of raised
floors
There are two general types of raised floors
• Traditional/Standard Access Floor (Post and Panel Raised Floor)

Can be above ground starting from 10cm to 180 cm 60x60cm


What are the types of raised
floors
There are two general types of raised floors
• Traditional/Standard Access Floor (Post and Panel Raised Floor)
• Low Profile Access Floor (Cable Management Floor)

Start from its own height to reach 10 cm


Example of Traditional/Standard Access Floor (Post and Panel Raised Floor)

highly controlled mixture of


Panel 24*24 lightweight cement
Up to 60*60
Example of Traditional/Standard Access Floor (Post and Panel Raised Floor)

highly controlled mixture of


Panel 24*24 lightweight cement
Up to 60*60

Understructure - Corner
Lock System
floor height from0.7 cm
to 6.0m
The Corner-Lock design
provides self-engagement
and positioning of floor
panels.
Example of Traditional/Standard Access Floor (Post and Panel Raised Floor)
Understructure - Bolted Stringer System

highly controlled mixture of


Panel 24*24 lightweight cement
Up to 60*60

Understructure - Corner
Lock System
floor height from0.7 cm
to 6.0m
Example of Traditional/Standard Access Floor (Post and Panel Raised Floor)
Understructure - Bolted Stringer System

Panel 24*24
Up to 60*60

Understructure - Corner
Lock System
floor height from0.7 cm
to 6.0m
Example of Traditional/Standard Access Floor (Post and Panel Raised Floor)
Understructure - Corner Lock System

Panel 24*24
Up to 60*60

Understructure - Corner
Lock System
floor height from0.7 cm
to 6.0m
Components of raised floor

Panel 24*24
Up to 60*60
Special physical raised floor
tile types
Airflow Panels & Controls
20% Open Area.
Dia. 6.8mm Hole, 2048 per panel.
Nominal Size: 600mm×600mm×35mm.
Perforated All-Steel construction.
Non-combustible material.
A variety of HPL, Vinyl Tiles are available.
Protected from corrosion by an epoxy paint
finish.
Accessories

Three Cup Lifter Two Cup Lifter

Air Sealing Grommet Adhesive for Pedestals


Accessories

Air Diffuser
Floor Socket Outlets
How to install the raised
floor system
install the raised floor system
install the raised floor system
2 3

4 5
install the raised floor system

6 7

8 9
install the raised floor system

10 11

12 13
install the raised floor system

14 15

16 17
install the raised floor system

18 19

20 21
install the raised floor system

22 23
How draw raised floor in
plan and section of
executional drawings
How draw raised floor in plan and section of executional
drawings
?
How draw raised floor in plan and section of executional
drawings
?
How draw raised floor in plan and section of executional
drawings
?
How draw raised floor in plan and section of executional
drawings
?
How draw raised floor in plan and section of executional
drawings
?
The end 

Any questions
?

You might also like