Cerclaje BMP

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

BIOMET C L I N I C A L I N D I C AT I O N S

A D VA N TA G E S A. Cable Im
• Femur
plants
a
• Proph nd tibia fractur
ylactic b es
• Stabil anding
ization
• Trocha
nt
Cable Implants • Hume eric reattachm
rous fra ent
• Olecra ctu
• 750mm in length, including non frac res
• Patell tures
ar
Combo packs • Ankle fractures
fracture
s
Cable Plates

BMP
• One piece sleeve and plate ™
design eliminates micromotion
• Lower total component cost
offers significant economical
advantage
i c Grip
Total System Trocha n t e r
eater B.
CABLE
t of gr
achmen
• Reatt er following
Approach trochan
t
tal hip
y for to anteric
t e o t o m
• Two cable sizes (2.0mm os och
o c e d u r es or tr
and 1.6mm) pr
ment
• Two cable materials (Cobalt advance
Chrome and Stainless Steel)
• Two trochanteric grips
(medium and large)
• Five cable plates SYSTEM
Instruments
• Tensioner adjustable cam
C . Cable Plates
• Fixatio
bar allows recentering n of fem
humera ora
without disassembly l fractur l, tibial, or
site of a es
• Tensioner T-handle incorpo- n intram near the
• Fixatio edullary
n of fra
rates a speed handle for quick a comb ctures w implant
ina here
release of the cable and cer tion of screws
• Reproducible racheting clage ca
improve ble
crimper prevents “over” stabiliza s would
tion
and “under” crimping
• Non-modular cable passers
facilitate ease of use
• Cable cutter with “offsetting
circle” design delivers clean,
BMP is a trademark of Biomet, Inc.
frayless cut to cable ends U.S. Patent No. 5,607,430

P.O. Box 587• Warsaw, Indiana 46581-0587 • (219) 267-6639 ©1998 Biomet, Inc. All Rights Reserved
web site http://www.biomet.com • eMail:biomet@biomet.com
Form No. Y-BMT-539/031598/K
I N S T R U M E N TAT I O N SYSTEM COMPONENTS
IMPLANTS Cobalt Chrome Implants
Part No. Size Description
120002 2.0mm dia. x 750mm Cable
120003 1.6mm dia. x 750mm Cable
120005 2.0mm Sleeve
Cables 120006 1.6mm Sleeve
All cables are made with a 7 x 7 T-Handle Tensioner 120010 2.0mm dia. x 750mm cable Cable/Sleeve
and 2.0mm sleeve Combo
construction. Seven individual • Cams automatically capture cable
BMP wires form a bundle and seven
bundles are combined to form
each cable optimizing strength
• Speed handle for quick release
of cable
120011
120007
1.6mm dia. x 750mm cable
and 1.6mm sleeve
2.0mm – Med
2.0mm – Lrg
Cable/Sleeve
Combo
Trochanteric Grip
Trochanteric Grip
120009
and flexibility.
Cables cross section
Crimper
CABLE Cobalt Chrome
• 2.0mm and 1.6mm
• Used with Cobalt Chrome and
• 20 to 1 mechanical advantage
• Rachet mechanism prevents
“under-crimping” by not allow-
T-handle Tensioner
Part No.
350800
Stainless Steel Cable and Sleeves
Size
2.0mm x 750mm
Description
Cable
ing release from sleeve until 350805 2.0mm Sleeves*(optional)
Titanium implants minimal crimp is achieved 2.0mm dia. x 750mm cable Cable/Sleeve
350806 and 2.0mm sleeve Combo

SYSTEM Stainless Steel


• 2.0mm
• Used with Stainless Steel
• Dead-stop mechanism in linkage
prevents “over-crimping”
• Precise and consistent crimping
*Not required for use of cable plate

316 L Stainless Steel Cable Plates


Cables of every cable sleeve No. of No. of Cable
implants and the BMP Part No. Length Screw Holes Locations
The Biomet Medical Products
(BMP™) Cable System provides Cable Plates 350813 110mm 3 4
a cost effective and simple
Cable Passers 350815 160mm 5 6
350817 210mm 7 8
method of trochanteric reat- Cable Sleeves • Two sizes to correspond with
bone diameter
350819 260mm 9 10
tachment, fracture fixation, 350821 310mm 11 12
Three sleeves are available: • Simple one piece construction
and cerclage cabling. Our
• 2.0mm CoCr
system features cable
• 1.6mm CoCr Cable Passers Stainless Steel 4.5mm Cable Plate Templates
implants based upon a clinically
proven design concept and
• 2.0mm Stainless Steel Cable Sleeves Trochanteric Grips
Cable Cutter Crimper
Cortical Screws
(Self Tapping) (Packaging–Single) Part No. Description
instrumentation that is a vast • “Offsettting circle” design Plate Template
Part No. Length 498012
improvement over competitive Trochanteric Grip produces clean cut frayless
cable end 18-235114 14mm
Set (5)
3 Hole Plate
cable systems. Our innovative • Cobalt Chrome 18-235116 16mm 498013
Template
cable plates offer both a • Two sizes (medium and large) 18-235118 18mm 5 Hole Plate
technological and economic • Two crimp locations Standard 18-235120 20mm 498015
Template
advantage that is exclusive to • No additional sleeves 18-235122 22mm
the BMP Cable System. The required Trochanteric Grip 18-235124 24mm 498017
7 Hole Plate
Template
BMP Cable System is the 18-235126 26mm
total system for the total Cable Plate
Impactor 18-235128 28mm 498019
9 Hole Plate

solution. Cable Plates • Simple impacting with plastic


18-235130 30mm
32mm
Template
11 Hole Plate
18-235132 498021
• Five lengths available impact surface to prevent 18-235134 34mm Template
(110mm–310mm) implant damage Cable Cutter
18-235136 36mm
• One piece plate and Cable Cutter offsetting 18-235138 38mm Instruments
circle design 40mm
sleeve construction
• Economical advantage
Manipulator/ 18-235140
18-235142 42mm
Part No. Description
44mm 498003 Crimper
• Compression capability
• Eliminates plate/sleeve
Impactor 18-235144
18-235146 46mm Std. Trochanteric
Traditional Design 48mm 498006
• Firmly clamps to trochanteric 18-235148 Grip Impactor
micromotion 18-235150 50mm
grip 498007 T-Handle Tensioner
• Doubles as plate holder by 18-235152 52mm
498008 Cable Passer – Lrg
Cable Plate clamping to plate crimp
18-235154
18-235156
54mm
56mm 498009 Cable Passer – Sm
sleeves 498010 Cable Cutter
Templates 18-235158
18-235160
58mm
60mm 498011 Trochanteric Grip
Biomet Design
• Five lengths available corre- 18-235164 64mm Manipulator/Impactor
sponding to plate size 18-235170 70mm 592038 Sterilization Case
Cable Plate Templates Manipulator/Impactor

You might also like