NO. DESCRITION
1 STERN TUBE SEAL SHAFT PROPELER PORT AND STBD LEAKAGE NEED TO BE RENEW.
2 REPLACE AFT SEAL OIL GEAR BOX PORT SIDE FOUND OIL LEAKAGE.
BLOWER ENGINE ROOM PORT AND STBD FOUND NOISY NEED TO BE CHANGE
3
BEARING AND MAGERING WIRING.
4 BLOWER CO2 ROOM FOUND NOISY NEED TO BE CHANGE BEARING
MAIN SEACHESE VALVE FOUND LEAKAGE DURING CLEANING STRAINER AND NEED TO
5
BE REPAIR.
6 FO QUICK CLOSING VALVE DAILY TANK FOUND LEAKAGE NED TO BE CHANGE.
7 FIRE ALARM SYSTEM EROR NED TO BE CALIBRATION.
FO AND WATER TANK VENTILATION FOUND DAMAGE AND CORODED NEED TO BE
8
REPLACE.
9 BOX BATTERY M/E AND A/E TO SMALL NEED MODIVICATION.
10 ENGINE ALARM SOUND AND SIGNAL LIGH NEED TO BE INSTAL IN ENGINE ROOM.
11 ENGINE INDICATOR GUAGE ON THE BRIDGE NOT WORKING NEED TO BE REPLACE.
12 SEVERAL VALVE OVER BOAT IN ENGINE ROOM NEED TO BE REPAIR.
13 ALL AC IN DOOR AND OUT DOOR NEED TO BE CLEAN.
14 REPAIR LINE ( TREE WAY LINE ) FRESH WATER SERVICE FOUND LEAKAGE.
AUXILIARY ENGINE
GENERATOR / ALTERNATOR NO.1 AND NO.2 NEED TO BE CLEAN WIRING AND
1
MAGERING