Professional Documents
Culture Documents
Technical Principles of Valves: Symbols and Circuit Functions
Technical Principles of Valves: Symbols and Circuit Functions
3/2-way valve;
when de-energized, port A exhausted Circuit Functions of 4-way Valves
Circuit function L The orifices (DN) available are given in All pressure figures quoted in this
mm and correspond to the diameter of catalog represent gauge pressures.
the valve seats. Pressure ratings are quoted in bar.
Our figures apply for the voltage range
Port Connection 10 %.
If 3/2-way valves are used in a different
In most cases, ports with threads circuit function, the permitted pressure
based on inch-systems (e.g. G 1/2 to range changes.
ISO 228) or metric threads are used. Care should be taken to ensure that
5/3-way valve, when de-energized, all Many devices are also available as the vacuum pump is connected to the
ports are closed. sub-base version. They are space- outlet ports of 2-way valves and to the
saving and can be mounted on R port of 3-way valves.
manifolds or fitted to customer The higher pressure, i.e. atmospheric
Circuit function N designed products. Manifolds must be pressure is thus always present at the
ordered separately. Some types are inlet port P.
also available with special port
connections.
Materials
5/3-way valve, when de-energized, All materials used in the construction +130 C FPM swells
outlet ports 4 and 2 exhausted of Burkert valves are carefully selected PTFE practically resistant against all
to suit a variety of applications. the fluids, unflexible,
Body material, seal material and normally
Flow-rate Values solenoid material are chosen to -20 to +180 C
optimize functional reliability, fluid
compatibility, service life and cost. Body Materials
The size of valve required for a Depending on the application, we
particular application is generally Seal Materials provide different body materials. The
established by the Kv rating to VDI/ The particular mechanical, thermal, most common materials used are
VDE 2173. This figure is evolved for and chemical conditions in an brass, gun metal, stainless steel, PVC,
standardized units and conditions, i.e. application are determining factors in PP, teflon, grey cast iron, steel cast
flow rate in m3/h. the selection of the seal material. The and glass fibre reinforced polyamide.
Kv ratings for each valve are quoted in standard material for neutral fluids at
the catalog. temperatures up to +90 C is normally Solenoid Materials
For valves which are also used for NBR. For higher temperatures and All parts of the solenoid actuator which
pneumatics, the air flow is also critical fluids FPM (Viton), EPDM and come into contact with the fluid are
indicated in QNn. PTFE (teflon) are employed. Steel is made of austenitic corrosion-resistant
used for hot fluids, particularly to reach steel. In this way, resistance is
Kv-Value: measured with water high cycling rates. The PTFE material is guaranteed against corrosive attack by
at inlet port universally resistant to practically all neutral or mildly aggressive media.
with free outlet at technically interesting fluids.
1 bar and +20 C. The Burkert product range includes Coil Material
Indicated in m3/h valves with all fluid-contacting parts of The solenoid epoxy encapsulation
this material. efficiently dissipates the heat
Cv-Value: Cv in USG/ generated by the coil.
min=1,165 Kv in NBR (standard material) resistant
m3/h against mechanical wear as
well as against oils and fats,
QNn-Value: (for gases) Indicated -10 to +90 C
in liter per EPDM resistant against bases and
minute (l/min) acids up to a medium
measured with air at concentration, for hot water and
+ 20 C and 6 bar steam, -40 to +130 C, not
and a pressure resistant for oils and fats.
drop of 1 bar FPM suitable for fluids, where, NBR
across the valve. and EPDM are not resistant, -10
to +130 C, when steam
temperature is higher than
Fluid Viscosity
The Burkert coils are available in all the the energized position, i.e. air gap is Most Burkert solenoid valves have
popular used AC and DC voltages. The closed. This results in a higher output been desigend for continuous
low power consumption, in particular and increased pressure range. In DC operation, i.e. they can stay energized.
with the smaller solenoid systems, systems, after switching on the current,
means that the control via solid state flow increases relatively slowly until a
circuitry is possible. The magnetic constant holding current is reached.
force available, increases as the air gap These valves are therefore only able to Temperature Range
between stopper and armature control low pressures, unless they are
decreases, irrespective whether AC or provided with smaller orifices. A time- We have listed the temperature limits
DC is involved. An AC solenoid system based comparison of the energization for several different factors. Various
has a larger magnetic force available at characterisics for AC and DC solenoids factors, e.g. ambient temperature,
a greater stroke, than a comparable is shown in Figure 2. cycling rate, operation behaviour,
DC solenoid system. The characteristic As well as the Burkert solenoid valves voltage tolerance, installation details
stroke - force graph indicated in Figure with standard coils, we also have can however influence the temperature
1 clarifies this relation. valves available with high voltage, performance.
At the moment of being energized, i.e. impulse and explosion-proof coil The values quoted by us should,
when the air gap is at its maximum, AC systems. therefore, only be used as a general
solenoid valves draw much higher guide. In cases where operation at
currents than when the armature is in extremes of the temperature range are
involved, you should seek advice from
Figure 1 Figure 2 your nearest technical sales office.
The admissible fluid temperatures
depend upon the seal and body
material used and may, with some of
the Burkert valves, amount to up to
+250 C. Ambient temperatures up to
+55 C are generally permissable.
Response Times
The small volumes and relatively high
magnetic forces involved with Burkert
solenoid valves enable rapid response
times to be obtained. The response
time is defined as the time from
electrical switching to the pressure rise
of 90 % or pressure drop to 10 % of
the max. possible operating pressure.
If the operating pressure exceeds 6
bar, the response times have been
determined at 6 bar.
The response times are depending
upon the respectively prevailing
atmospheric pressure, the viscosity of
Electrical Connection On Period the fluid and the system configuration.
For special application requirements
The solenoid systems of the Burkert The on period is defined as the time Burkert provides valves with adjustable
standard program provide one plug- between switching the solenoid current switch-on times.
type connection. The cable plugs, on and off. The total time of the
which in most cases are provided with energized and de-energized periods is
the product are suitable for the cycle period.
connections with a diameter of 7 mm. The relative duty cycle is the
Other versions of electrical percentage ratio of the energized
connections are available on request. period to the total cycle period.
energized period
DC = x 100 (%)
total cycle period
Solenoid Valves
Direct-acting Solenoid Valves
Notes
Do not select servo-assisted valves
with larger orifices than their pipe cross
section. (Figure 5)
Pneumatic Cylinders
With these valve types, an independent Advantages of an externally piloted The independent medium is controlled
pilot medium (air, water) is used to valve: by a 3-way solenoid valve, which can
actuate the valve. In most cases, these 1. High flow rate (large valve stroke) be fitted to the actuator.
are piston or diaphragm controlled 2. No differential pressure of operating
valves. fluid required
3. Option of reversed flow direction
to reduce water hammer
4. Use in hazardous areas (e.g. as pilot
valve in the control room)
5. Control of higher pressures with
larger orifices.
The angle seat design (Figure 6) The is a wide choice of actuator sizes
provides a very favourable flow rate and body materials to suit different
and the design reduces the possibility applications with hot, highly viscous
of dirt being deposited in the valve. and aggressive fluids.
Figure 6:
Piston-operated angle seat valve
The PVC or stainless steel 2-way The valves are maintenance-free and Burkert has many years
valve bodies extremely robust and can be retrofitted experience of the
provide high flowrates and are with a comprehensive range of development and
available in a number of surface accessories, e.g. electrical position production of explosion-
finishes to suit different applications. feedback, stroke limitation or manual proof solenoid valves.
The diaphragm between the actuator override. We have summarized
and valve body hermetically isolates all the important details for you in a
the fluid from the actuator (Figure 7). special Ex-brochure.
Underwriters
Laboratories Inc.
Canadian
Standards Association
GL-Approval
VDE-Approval
Norske Veritas