Drcpowamp
DRC Series
31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com
DRC Series
Power Amplifiers
Features
• Easily configured using software or hand held interface
• LED indication of power, output current and fault status
• Compact DIN-rail mount housing
• Multiple modes for single and dual coil applications
• Input options include -10V to 10V, 0 to 20mA
• Programmable enable input
• All input and output limits are independently adjustable
• Adjustable current limited output with short circuit protection
• +10 and -10 volt references for potentiometer/ joystick controls
• Adjustable ramp up and ramp down rates
• Selectable dither frequency up to 1000 Hz DRC4-V-12
• Microprocessor controlled for consistent, reliable performance
Specifications Wiring
Standard Working Conditions Terminal functions are listed in the table below.
• Supply Voltage . . . . . . . . . . .9 to 32 VDC J6
1 2 3
Terminal Function
• Supply Current . . . . . . . . . . .lSOL + 50 mA
J5 J1-1 +V Supply
• Output Current . . . . . . . . . . .DRC*-V-12 = 1.2A max. 1 2 3
J4
J1-2 Supply Common
DRC*-V-25 = 2.5A max.
1 2 3 J1-3 Enable Input
• Solenoid Resistance . . . . . . .2 Ω min.
J2-1 Output Ch. 1
• Reference Voltages . . . . . . .=10V, -10V @ 20 mA DRC4
J2-2 Common
• Dither Settings . . . . . . . . . . .30, 50, 75, 100, 125, 150,
J2-3 Output Ch. 2
175, 200, 225, 250, 275,
USB
Communication with the DRC takes place through the USB port. The
port allows for configuration and monitoring of the operating parameters.
31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com
DRC Series
Power Amplifiers
Applications
DRC1- V-* (Single Solenoid Joystick Control) DRC2- V-* (Double Solenoid Joystick)
The DRC can be controlled with a joystick or potentiometer The DRC can be setup to drive a double solenoid valve
as shown. The recommended potentiometer value is 10kΩ. using one command as shown in the following diagram. If
Mode 1 may be used rather than Mode 2 if the enable is enable is not used, C1 Mode shoul be set to 1 and C2
not used. Dither and Output settings will vary depending on Mode to 3. The minimum and maximum input parameters
the valve and application. for the two channels must be set such that both outputs will
J1
not be active with the same input signal. The settings do
1
2
not have to be the same or mirrored between the two chan-
4 AMP EMERGENCY STOP
3 nels as shown in the example though in many cases they
POS
J1
ENABLE 1
EMERGENCY STOP 2
4 AMP
3
POS
J4
1 9 to 32 VDC
2
NEG
CW
J2 3 ENABLE
1
1
JOYSTICK
2 W
3 J5
1 J4
2
1 1
VALVE 2 2
CCW
2
3
CW
J2 3
1
2 JOYSTICK
W
3
J5
3 1
4 2
CCW
3
VALVE
J4
1
DRC4- V-* (Double/ Single/ Single Solenoid) JOYSTICK 1 2
J2 CCW CW 3
1
3
1
for command inputs. Dither and Output settings will vary depend- VALVE 1 2
3
ing on the valves and the application.
JOYSTICK 2
CCW CW
J1 J3
1
1
1 2
J6
W
EMERGENCY STOP 2 3 1
4 AMP
3 2
POS
VALVE 2 3
9 to 32 VDC JOYSTICK 3
CCW CW
NEG
ENABLE
W
2
VALVE 3
Ordering Information
DRC 1 - V - 12
31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com