CONNECTION NEW COLUMN TO EXISTING
1. GENERAL
This calculation sheet will calculate connection new column to existing in Workshop
2. CALCULATION
Additional Stiffner
Stiffner 1 : 113 x 12 = 1356 mm2
Stiffner 2 : 94 x 12 = 1128 mm2
M = W x a2
2
when :
W = Uniform Load on support
a = overhanging length
2 of 4 .
CONNECTION NEW COLUMN TO EXISTING
2
178527 200
x
M = 200 2
2
= 4463177 Nmm
t =
√ 6M
L σbc
, where σbc : fy/Ωt Ωt (ASD) :
σbc :
1.67
141 Mpa
=
√ 6
200 x
x 4E+06
141
= 30 mm
● Use plate thickness 30mm
Check Bending stress & Shear Stress in base plate stiffner section
P = Aσ
= 11978 x
178527 x 1
200
= 10691987.2 N
Mp = Pg
= 10691987.2 x 77
= 823283011.6 Nmm
3 of 4 .
CONNECTION NEW COLUMN TO EXISTING
σb = 2988.12 Mpa
Bending stress
σb = Mp Cb
I
= 823283012 x 77
69706250
= 909.43 Mpa
σt = Mp Ct
I
σt = 909.428 Mpa
= 823283012 x 253
69706250
= 2988.1 Mpa > 909.428 Mpa (OK)