NSFC01-01A controller produced by Ascensores Seervas SA is a special door-controller.
The operation manual mainly introduces using method and points for attention of the
NSFC01-01A door-controller. You must read the service manual before you use the door
controller so that you can use it correctly.
1 Classified points for attention
Security points for attention
You must read this handbook before installation, operation, and maintenance, check so that
you can use it correctly.
You can use it after you are familiar with the situation of the relevant facility, security
information and its points for attention.
The column of security points for attention in the service manual is divided into the two
grades: “danger” and “attention”
Danger: danger will appear when there is wrong operation, which can possibly cause
death or serious injury.
Notes: danger will appear when there is wrong operation, which can possibly cause
medium or slight injury and the damage of the goods.
In addition, although remembering the notes, because of different situations, it can also cause
serious results.
The recorded contents in these two situations are all very important, please strictly obey.
1.1 Installation
Attention
Install on the fireproof matters like metal to avoid fire.
� Please do not get close to inflammable matters in order to avoid the fire.
� Please do not hold the terminal’s outer cover by hand during carrying in order to avoid
dropping and damage.
� Do not let the metal fillings drop in order to avoid fire.
� Please install in the place where it can bear its weight according to the operation manual
during the installation in order to avoid dropping and damage.
� Please do not install the lift door’s controller that is damaged or lack of parts in order to
avoid injury.
1.2 Connection
Danger
� Connect the lines after the confirmation that the power is off. When the input power is off,
wait for more than 5 minutes, and then connect during the connection, so as not to touch the
electricity and cause injury.
� Please connect the ground wire in order to avoid electric shock and fire.
� Please trust professional electrician to connect the lines in order to avoid electric shock
and fire.
� Please connect the lines after the entity installation is finished in order to avoid electric
shock and injury.
Attention
� Do not connect the alternating-current power in the output terminals of U、V、W in
order to avoid injury and fire.
1
V2009-1
NSFC01-01A INSTRUCTION MANUAL
� Please correctly connect the wiring of the motor. The door- controller cannot operate
when there is something wrong with the wiring. In order to avoid injury and fire.
� Please correctly connect the control terminal. The door- controller cannot operate when
there is something wrong with the control terminal.
� Confirm that the unanimity of the rated voltage and the voltage of the alternating-current
power in order to avoid injury and fire.
� Please use the designated tools to fasten the screw of the terminal in order to avoid the
fire.
1.3 Operation
Danger
� Input the power after the cover of the terminal is covered. Please do not open the cover of
the terminal during the electrifying in order to avoid electric shock.
� Do not operate the button with the wet hand in order to avoid electric shock.
� Although the lift door’s controller is under the status of stopping during the electrifying,
please do not touch the terminal of the lift door’s controller. In order to avoid electric shock.
� Please use the function of tramping and detecting after full confirmation of the security
and function of the lift’s main control system in order to avoid injury.
� Must input security sensor to the lift’s main controller and make tramping and detecting at
the terminal of the main controller. The function of tramping and detecting of the lift’s door
controller will not act when it reaches the closed position. Please take double safe measures
in order to avoid injury.
� Please must input the arrival signal to the lift’s main controller (limit switch and so on)
and make the arrival detecting at the terminal of the main controller. Please not make the
arrival detecting only by open/closed arrival signal of the lift door’s controller in order to
avoid injury.
Attention
� Radiating fin is a part of radiating. Please do not touch in order to avoid scalding.
� The lift door’s controller can be easily settled to operate from low speed to high speed.
Please make sure that it operates within the permitted range of the motor and facility in order
to avoid injury.
� Please fully confirm the corresponding function when you use without the arrival signal.
(Please take measures to ensure the security of the body, then operate) in order to avoid
injury.
� The direction of the door will change automatically during the repeated control and the
measurement of the door’s width. Please take measures to ensure the security of the body,
and then operate in order to avoid injury.
� When the controller’s power is on, the door machine started by permanent magnetism
synchronous motor will firstly open and close the door at a slow speed and speed impact
may happen. Please take measures to ensure the security of the body, and then operate in
order to avoid injury.
� Please adjust and confirm each parameter. Some accidental movements will appear
because of different settlement of parameter in order to avoid injury.
Danger
� Please cut off the input power when making maintenance and checking. Wait for more
than 5 minutes and then continue in order to avoid electric shock.
2
V2009-1
NSFC01-01A INSTRUCTION MANUAL
� The persons who are not appointed can not make maintenance, check and parts
replacement
[Please take off metal things (watch, bracelet, and so on) (please use tools with insulation
protection) in order to avoid injury.
Attention
� Please trust the professional electrician to fasten the screw of the terminal regularly. If
screw’s terminal is loose, it can result in overheat and fire.
� Please turn off the power switch of the door controller when making voltage-resistant and
insulation measurement on the door machine in order to avoid damaging the door controller.
� When making voltage-resistant and insulation measurement on the power inputting wires
of U, V, and W, please take the three wires apart from the terminal of the door controller and
then operate in order to avoid damaging the door controller.
� Please do not make voltage-resistant and insulation measurement on control wire and the
terminal of the encoder (the voltage is below DC 24V) in order to avoid damage of the door
controller.
1.5 Others
Danger
� Please do not use the load except that of three-phase induction motor and permanent
magnetism synchronous motor.
� Please do not decompose and transform the product in order to avoid electric shock and
injury.
3
V2009-1
NSFC01-01A INSTRUCTION MANUAL
minutes, and then continue. The radiating fin is under the high temperature during the
operation, so please
do not touch it by hand.
◆Obstacle of electric wave
The lift door’s controller contains high frequency harmonic wave, which can interact the
nearby
communication facility like AM radio. Interaction has something with the strength of the
electric wave,
which cannot be eliminated completely.
The ways of changing the direction of radio, setting up the noise filter to the metal box and
using the wire
pipe all can reduce the interaction. (Please consult separately)
◆Please do not make insulation resistance test between the wires. When measuring the
insulation resistance
between the power wire and the electromotor wire, please disconnect the connection of the lift
door’s
controller and measure by wire. Please do not make me ohmmeter measurement on the control
circuit.
◆Please do not use power terminal and load terminal of the electromagnetism contactor to
start and stop the
electric motor (lift door’s controller). Making frequent operation of ON/OFF on the power
terminal will
cause the obstacle of the lift door’s controller. When the lift door’s controller is under the
operation,
Making frequent operation of ON/OFF on the load terminal will cause the lift door’s controller
uncommonly jump out of the brake. Using the operation signal of the switch of the lift door’s
controller to
start and stop the motor.
◆Please do not install phase modulation condenser or surging stopper on the input terminal of
the lift door’s
controller. It can cause the obstacle of lift door’s controller or the damage of the condenser. If
connected,
please take it apart.
◆Please do not use the load except that of three-phase induction motor and permanent magnet
synchronous
motor.
◆Points for attention related with the protection of the lift door’s controller
The lift door’s controller has multi-function like restriction of built-in electric current and
protection of
passing electric current. The protective functions protect the lift door’s controller during using
in order to
avoid the damage of the fittings when they are under the strange situation. It is not the
common using
function. Therefore, when using please avoid using these functions under common situation,
otherwise it
8
will reduce the life of the lift door’s controller and even make it damage.
Please confirm that all points for attention in the service m
◆ anual and the specification of goods are out of question when you use it.
4
V2009-1
NSFC01-01A INSTRUCTION MANUAL
1).To check if all connection is correct, especially power terminal connection and load
terminal connection, and the door inverter will be damaged if worry connection.
2). To check if rated voltage of door inverter and power voltage is same.
3).To check if motor connect to phase-input capacitor, if connected, the door inverter and
capacitor wi
3).To check if motor connect to phase-input capacitor, if connected, the door inverter and
capacitor will both failure.
2、Terminal Function
Name Cable code Function description
(color )
L / N / PE Brown /blue Single phase power supply
/(yellow&green)
OP 2# Input signal: open door (NO)
CL 3# Input signal: close door(NO)
OPI --* Input signal: open limit(NC)
CLI --* Input signal: close limit(NC)
DECO --* Input signal: open speed down(NC)
DECC --* Input signal: close speed down(NC)
ENI Fire function terminal
GNDE 1# Open/close input common port(COM)
U/V/W U/V/W Motor terminal
OPO 5# Output signal: open limit
CMO 4# Open close limit output common port
CLO 6# Output signal: close limit
CMC 4# Close limit output common port
Y-1 Multi-output
standby
Y-2 Multi-output common port
Not ice : 1. the cable with sign --*has been connected in door system , the 6-core wires
control cable should be connected to main control system by user
2. Signal input terminals should be connected with the non-voltage signal or open collector
signal. signal terminal voltage isfor the +24 VDC, input common port GNDE is negative.
3、Keypad &Operation
5
V2009-1
NSFC01-01A INSTRUCTION MANUAL
3. 1 Keypad Definition
operation panel
UP
display
MODE RUN
MODE RUN
DOWN
Name Function
To switch Mode:000 & parameter type : p,d,n
To enter the menu and store data
Modified data and set the forward direction
Modified data and set the reverse direction
start running the door controller
stop running the door controller
Note:1.if enter the menu not in mode000, please press the key & , then the
relevant number will be increasing or decreasing.
2. after modifying the data, press to store them, and exit this menu and enter in to
next parameter.
3.when run the door controller, the user has to press or before pressing
, other wise the contrller won’t run.
3. 2 Keypad Basic Operation
Setting example :Change parameter P05 equal to 22
6
V2009-1
NSFC01-01A INSTRUCTION MANUAL
Press to return
to operation preparation
Figure 1
Notice :please set P01=1 before modify the data.
4、Connection Diagrams
opening 2#
OP closing 3#
NC W
CL open complete
OPI close complete
M CLI
V
PE DECC
Fire function terminal
ENI
door controller GNDE input common port 1#
OPO
open complete common port 4#
CMO
close complete output 6#
CLO close complete common port 4#
CMC
multi-output
L
Y-1
Multi-output common port
Y-2
AC220V
figure 2
Notice :
[1] Make control line and power line separately when connect to main controller.
[2] To be sure the match of the open/close door output logic of door controller and the
Open/close door input signal logic of main controller, when connect to the signal of
Open\close.The initial status of door controller is normal close(NC).
User can select relevant logic status, please refer to the parameter P16 and P17, make 0=
output signal: open door, make 1=output signal : close door
5、Fast Adjustment
7
V2009-1
NSFC01-01A INSTRUCTION MANUAL
Inner wires have been connected and the fuction adjustment has been done before the
controller leave factory. Users could adjust opening/closing curve as the following sept 1-3
according to the actual position
Note: please confirm the following solid line have been connect before power on
opening 2#
OP closing 3#
NC W
CL open complete
OPI close complete
M CLI
V
speed down in opening
DECO
U speed down in closing
PE DECC
Fire function terminal
ENI
door controller GNDE input common port 1#
OPO
open complete common port 4#
CMO
close complete output 6#
CLO close complete common port 4#
CMC
multi-output
L
Y-1
Multi-output common port
Y-2
AC220V
figure 3
Note: if change the parameter in running, motor load will change a lot, sometimes could stop or restar
suddenly, so please take measure to avoid accident.
When replace the battery, opening/closing in speed down and complete opening/closing,
please check the signal normal or not by following steps.
6. 1 Confirmation of the I/O signal (parameter n07,n08,09).monitor.
Press and change to n model, and then press or to get the relevant monitor
parameter, and will get the sinal position by pressing
8
V2009-1
NSFC01-01A INSTRUCTION MANUAL
figure 4
②--close door signal
③--open limit signal
④--close limit signal
⑤—speed down in openg
⑥-- speed down in closing
⑦—fire protection signal figure 4:n07 display
Polarity is independent. the signal terminal connected with the common port (GNDE), The relevant
nixietube with be lighted, if the signal terminal not connected with common port (GNDE),
the nixietube won’t be lighted.
the validity of output signal is relevant to the polarity. Set the polarity of opening limit relay ,closing
limit relay, milti-relay equate to P16、P17、P18, the fuctions are as follows:
0---- if the signal is valid, the relay output terminal connected with the common por, ,the relevant
nixietube with be lighted. if the signal is invalid, the relay output terminal not connected with
common port , and the nixietube won’t be lighted.
1---- if the signal is invalid, the relay output terminal connected with the common por, ,the relevant
nixietube with be lighted. if the signal is valid, the relay output terminal not connected with
common port , and the nixietube won’t be lighted.
9
V2009-1
NSFC01-01A INSTRUCTION MANUAL
Note: if the door closing without enough force, please increase thevalue of P02 properly
7.1.1 When having opening signal, car door operator enhance low-speed torque P02, running
speed d05, After acceleration time d15,the target value is d06,then to open the door
to enter the high-speed operation.
7.1.2 When the door run the position of opening door speed –slow switch, car door operator
will slow down from d06to d07, after acceleration time d16,then run low speed .
7.1.3 When door run the position of opening arrival switch, car door operator run slow down
from d07 to d08
7.1.4 when door run the position of opening limit, keep d10 to run.
frequency
closing arrival keeping opening course opening arrival keeping
d06
d07
d08
d05 d15 d16
d10 distance
door zone position
openging signal
closing signal
opening arrival signal
(2) If opening torque is small on low speed position, increase P02 value,if P02 is big, May
cause motor over-current or over-temperature protection
10
V2009-1
NSFC01-01A INSTRUCTION MANUAL
frequency
opening arrival keeping closing course closing arrival keeping
d02
d03
d04
d01 d13 d14
d09 distance
door zone position
closing signal
opening signal
closing arrival signal
Notice:
(1)closing door arrival keeping frequency is d09,keeping torque is P05。
(2)if the close door torque is small, increase P02 value。If P02 值 value is big,May
cause motor over-current or over-temperature protection
8、function data
8.1 display and inspect data
No. Data name unit note
n01 Running speed HZ
n02 Running current A
n03 Input voltage V
n04 Running times Time
n05 Electrify time
n06 Current zero value -
n07 Input signal state -
Refer to 6.1input output signal
n08 Input signal position state -
Monitor。
n09 Output relay state -
n10 Latest first fault -
n11 Latest second fault - Refer to 10fault code instruction.
n12 Latest third fault -
n13 Inverter edition -
11
V2009-1
NSFC01-01A INSTRUCTION MANUAL
12
V2009-1
NSFC01-01A INSTRUCTION MANUAL
13
V2009-1
NSFC01-01A INSTRUCTION MANUAL
14
V2009-1
NSFC01-01A INSTRUCTION MANUAL
will back to 0
P02 Low speed torque improve 14 14 percent
This parameter to change low speed output torque
P03 High speed torque improve 80 50 percent
This parameter to change high speed output torque
P04 Full opening remain torque 13 13 percent
When door is full opening,controller will output torque as per this parameter
P05 Full close remain torque 9 9 percent
When door full close, controller will output torque as per this parameter
P06 Opening torque loop max 180 120 percent
voltage
This parameter to set max output torque when opening
P07 Closing torque loop max 100 100 percent
voltage
This paramter to set max output torque when closing
P08 Closing decelarate torque 60 50 percent
loop max voltage
This parameter to set output torque loop max voltae when closing decelarate
P09 DC brake voltage 30 30 percent
This paramter to set DC brake torque
P10 Max torque 200 200 percent
This parameter to set inverter max output torque
P11 Overload protect current 1.80 1.80 Amp.
If running curren bigger than this value, it will be overload protected
P12 Closing overload current 1.08 0.83 Amp.
when accelerate and
decelarate
When closing door is accelerate or decelerate,if current bigger than this value, inverter will
treat as closing overload current
P13 Closing overload current 0.62 0.46 Amp.
when smooth running
When door is smooth running,if current is bigger than this value, inverter will treat as
closing overload current
P14 Current zero value 560 560 -
This parameter to set current sensor zero value
P15 Closing overload reopen 1 1 -
enable setting
If this parameter is 0,door will keep closing when overload appears
If this parameter is 1,door will open when overload appears
P16 Full opening relay pole 1 1 -
setting
This parameter to set full opening relay pole setting,that is
0:when full opening,terminal OPO、CMO will short;when door at other place,
terminal OPO、CMO will cut。
1:when full opening,terminal OPO、CMO will cut;when door at other place,
15
V2009-1
NSFC01-01A INSTRUCTION MANUAL
16
V2009-1
NSFC01-01A INSTRUCTION MANUAL
17
V2009-1
NSFC01-01A INSTRUCTION MANUAL
18
V2009-1
NSFC01-01A INSTRUCTION MANUAL
complete relay
When door is in closing complete, inverter will postpone received signal of closing
complete to this set time , then output through closing complete relay
Door operator speed-down 0.10 0.10 second
d27
time when emergency stop
When door is changing from running to 0 speed( such as repairing open door、repairing
close door), the speed-down time will be set by d27. if this parameter is so small, there
will be impact when emergency stop; if this parameter is great, it will slide some
distance when emergency stop.
Revision delay time for 0 0 second
d28
door operator
When door is in opening to closing or from closing to opening, it will perform function
after set given time,setting number shoud be more than d27。
d29 Time for operating reset 10 10 minute
When revise operating parameter from P01 to 1, if in the period of given time for this
parameter, there is no key-press, then inverter will revise P01 to 0 automatically, the
given unit is : minute
Tect total time for opening 16.0 14.0 second
d30
and closing door
When door is in opening/closing automatically,this parameter should set total cycle time
for opening/closing door, and time for opening and closing should be in half
detect filtering time for 6 6 milliseco
d31
currenct nd
This parameter set filtering time of current
filtering time of given 6 6 milliseco
d32
speed nd
This parameter set filtering time of given speed
19
V2009-1