Standard: LRFD
Shear Plate Description
Connection Details
Connection Capacity
P = 230.9kN; (Plate Strength On Axial Load)
V = 116.3kN; (Bolt Checking)
Design efforts
Case name M P V
SimpleMaxTorsor 0kNm 2.7kN 95kN
Welds thickness
Weld name Thickness
Weld Strength On Main Beam 6.3mm
Profile width - thickness ratio
Profile width - thickness ratio
b/t < 0.56 * SQRT(E/Fy)
100mm/12mm < 0.56 * SQRT(200000N/mm²/248.2N/mm²)
8.33 < 15.9
OK
Bolt Checking
Conditions
Bolt Horizontal Start Distance ≤ 3.5 inch or 90mm
40mm ≤ 90mm
OK
Bolts on beam: [J3]
Minimum Bolt Edge Distance [J3.4]
Minimum Bolt Edge Distance ≤ Bolt Edge Distance
22.2mm ≤ 30mm
OK
Maximum Bolt Edge Distance [J3.5]
Bolt Edge Distance ≤ min (6 inch or 150 mm, 12*min(connected objects thicknesses))
30mm ≤ 96mm
OK
Bolts on connecting object: [J3]
Minimum Bolt Edge Distance [J3.4]
Minimum Bolt Edge Distance ≤ Bolt Edge Distance
Vu ≤ nObj*Phi*C*rnv [Part 7]
95kN ≤ 1*0.75*2.1*121.9kN
95kN ≤ 192.4kN
49.4 %
OK
Local Buckling
Vu * e ≤ Phi * Fcr * Snet [9-6]
95kN*130.5mm ≤ 0.9 * 1853.6N/mm² * 67.9cm³
12.4kNm ≤ 113.3kNm
10.94 %
OK
Conclusion
The connection is correctly designed to resist the applied forces