Professional Documents
Culture Documents
Caie As Biology 9700 Practical v1
Caie As Biology 9700 Practical v1
ORG
CAIE AS LEVEL
BIOLOGY (9700)
SUMMARIZED NOTES ON THE SYLLABUS
CAIE AS LEVEL BIOLOGY (9700)
scales of
the eyepiece graticule and the micrometer Useful for replicated readings.
scale in the field of
view Gradient = Δx Δy
, where
Δy & Δx are height and width
Count the number of divisions on the eyepiece
of triangle.
graticule and
compare them to a known length on the Draw right-angled triangle from 2 points on straight line
micrometer scale to figure
out the length of one
graph or
tangent of curve; Ensure that triangle exceeds
eyepiece unit
half of graph.
Repeat steps 1-3 with the medium-power and high- Final – Initial
% change = Initial × 100%
power objective
lens.
uncertainty
percentage of uncertainty = × 100
actual measurement
1.3. Variables
1.2. Magnification & Mathematics
Independent Variable is the factor whose values are
Magnification, M = Image size, I / Actual size, A decided (and can
be changed) by the experimenter. It is
plotted on the x-axis of the
graph. (Bold in examples)
Calculating the magnification of a photomicrograph or an Dependent Variable is the factor whose results need to
image be collected
during/after the experiment. These results
Measure the width of the cell in mm on the are out of control. It is
plotted on the y-axis of the graph.
photomicrograph using
a ruler (Italics in examples)
Convert the measurement from millimeter to
micrometer. Enzyme concentration on the rate of
activity of rennin
Apply magnification equation, using given value of the Temperature effects on the rate of
activity of catalase
actual
size. Surface area effects on the rate of
diffusion
Calculating magnification from a scale bar Concentration of a solution effects
on the percentage of
Measure the given scale bar using ruler onion cells that become
plasmolysed.
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
Standardized Variable is the factor that can affect the rate Anomalous readings are too low/too high/does not fit the
of
reaction, reducing the reliability of the experiment. It is trend and
are usually discarded, and the experiment
also
known as control. repeated.
Quantitative tests require numerical measurements to be
taken.
1.5. Modifications & Improvements of
Qualitative tests require the quantification of
observation, i.e.
the presence or absence of starch in a experiments
sample after performing the
starch iodide test.
Semi-quantitative tests are used to confirm the presence To standardize temperature, use thermostatically
of certain
chemicals in a sample, and their approximate controlled water
bath
concentration. In
Benedict’s test, red colour shows Use colorimeter instead of colour chart to compare
presence of sugar in high
concentrations, whereas yellow colours.
colour shows presence of sugar in low
concentrations Use buffer solutions to standardize pH, datalogger and
pH sensor to
measure pH.
1.4. Common Errors in Experiments Use same size/shape/volume/mass/surface area of the
prime sample of
investigation (e.g. potato strips/leaves)
from the same plant/potato
when experimenting for
Difficult to judge/compare colour/colour change using
effects of other independent variables on the
colour charts.
strips/leaves.
In experiments that use water-baths, temperature of the
Use larger numbers of the prime sample of investigation
test tube
falls when it is removed from the water bath.
(e.g. potato
strips/leaves)
Fast changes in colour/formation of bubbles can cause
Use digital balance to measure mass accurately.
errors in
timing, i.e., stopwatch started/stopped
To keep surface area constant, use Vernier calipers to
late/early.
measure
lengths and sharp scalpel to cut (e.g. potato
Difficult to start/stop stopwatch and add/remove samples
strips).
at the same
time.
Use graduated pipettes to measure small volumes of
Difficult to judge and count the number of cells that are
solution
accurately.
plasmolysed.
In Benedict’s tests, heat samples for the same amount of
In experiments where length/width/diameter of specimen
time.
is measured,
error occurs due to difficulty in focusing
Carry out experiments for the same amount of time if
both ruler and specimen
at the same time; parallax error;
time is not the
independent variable. To do this, stagger
thickness of ruler lines.
start or carry out
experiments separately.
In immobilizing enzyme reactions, error can occur due to
Carry out experiments at wider ranges of
sodium
alginate beads:
temperature/concentrations
(at least 5)
sticking to the sides of the tube
Make wider ranges of concentration using serial or simple
sticking together with those already dropped
dilutions.
floating up under each other
Repeat experiments at each temperature/concentration
In experiments that require shaking of test tubes, errors
3-5 times AND
take the mean of results.
can occur
due to uneven shaking/varying forces used to
Keep volumes of solution same throughout all the
shake the tubes.
repeats (using
graduated pipette/burette).
Errors can occur due to different sizes of bubbles,
During Benedict’s tests, keep temperature at around 80-
difficulty in
counting number of bubbles (fast formation).
100 degrees
Celsius.
In experiments that require formation of drops using
Use same volume of Benedict’s solution in all tests.
syringe, error
due to different sizes of drops as pressure
Cover H2O2 with lid/aluminum foil to prevent
applied on the syringe.
In experiments that require measurements to be made degeneration.
using eyepiece
graticule and stage micrometer, errors Dry test tube with white towel or use new test tubes
can occur due to before starting
each experiment
Difficulty in judging the edge of the specimen To prevent evaporation, use rubber bungs in test tubes
irregular shape of specimen. or cover the
containers (air-tight).
Errors can occur due to decrease in Hydrogen peroxide To standardize the position of delivery of solution into a
concentration
if left open, as H2O2 degenerates. test
tube, make a mark on the test tube.
Use magnetic stirrer to prevent errors caused by uneven
Errors can occur if test tubes used are not dry, as
shaking of
test tubes.
droplets on
water on sides of test tube can reduce
experiment’s reliability.
increase evaporation rates in experiments
Systematic errors occur throughout the experiments, as
Increase temperatures using thermostatically
they result
from uncertainties in measurements.
controlled water
bath.
Random errors differ across experiments as they arise
Increase wind speed using fan (keep fan speed
due
difficulties in controlling standardized variables and
constant).
measurements
of dependent variable.
Decrease humidity using fan or
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
(calcium/sodium/potassium) Mitosis
hydroxide/chloride/oxide
Silica gel/drying agent
dehumidifier
In experiments where oxygen is released, gas syringe can
be used to
collect oxygen; oxygen sensor can be used to
detect oxygen produced.
Burettes can be used to make drop sizes similar since
pressure is
not applied as in syringes.
To control the effects of light intensity, the lamp can be Early Anaphase
set at a
constant distant/power.
Place a container of water in front of the lamp to act as a
heat
shield.
Alter light intensity by increasing power or adding more
identical
lamps.
Other standardized variables include mass,
concentration, volume,
source, age, storage, conditions,
and genotype of sample depending
on the requirements
of the experiment. Late Anaphase
Preparation
Transverse section of Stem
Two common types of dilution are:
Simple, where a stock solution is diluted by different
ratios:
STOCK solution Final solution
Volume of
Conc. / Conc. /
Volume H2O added Volume /
mol dm −
mol dm −
− 3 − 3
/ cm / cm cm − 3
3 3
1.0 80 2.0 0.8 10.0
1.0 6.0 4.0 0.6 10.0
1.0 4.0 6.0 0.4 10.0 Stem Collenchyma
1.0 2.0 8.0 0.2 10.0
2. Photomicrographs of
Specimen & Biological
Drawings
Sclerenchyma
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
Pith of Stem
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
Sieve Tubes
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
Plant Cell
Protoctists (Amoeba)
WWW.ZNOTES.ORG
CAIE AS LEVEL BIOLOGY (9700)
WWW.ZNOTES.ORG
CAIE AS LEVEL
BIOLOGY (9700)