Feeding for control box & commands: Tension ⇒ Voltmeter
Groundconnection: Continuity ⇒ ohmmeter Sensors: Resistance ⇒ ohmmeter Signal ⇒ voltmeter Drive solenoids: Resistance ⇒ ohmmeter Harness: Continuity ⇒ ohmmeter Control box: If previous checks were all correct, the box has failed.
FUNCTION CONTROL CONNECTOR N° VALUES
Feeding voltage 1 - 10 - 12 ≈ 12,4 v
Ground continuity 2-3 0Ω Engine rpm sensor resistance 4 ⇔ 11 ≈ 138 Ω model w.counternut ° ° ≈ 1040 Ω model direct fit
Inching resistance 13 ⇔ 28 ≈ 5.6 to 6.2 kΩ at rest
potentiometer green red ° ≈ 260 to 900 Ω pedal fully ° ° stroked
Inching resistance 28 ⇔ 5 ≈ 400 to 900 Ω at rest
potentiometer red yellow ° ≈ 5.6 to 6.2 Ω pedal fully ° ° stroked
Inching resistance 13 ⇔ 5 ≈ 5.2 to 6.3 kΩ at rest or
potentiometer green yellow ° pedal fully stroked ° °
Switch work mode continuity 23 ⇔ 25 0 Ω or infinit when flipping
Lever FWD – REV voltage FWD : 9 ⇔ ≈ 12,4 v
REV : 27 ⇔
FWD & REV resistance FWD : 21 ⇔ 19 ≈ 5,8 to 6.7Ω
Solenoids REV : 20 ⇔ 19 ° °
Coil on drive motor Resistance EV8 situated on the 4,8 Ω