SAUDIARAMCO.

TYING WIRE 450mm C/C


STAINLESS STEEL CONCERTINA
NOTES:
BARBED TAPE CBT-65 CORE WIRE 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
TOP RAIL 60.3mm DIA 75.0mm O.D. RAIL COUPLING LINE POST DIA 2.5mm GALV., TAPE WIDTH OTHERWISE NOTED.
@ JOINT AND EXPANSION 21mm, BARB LENGTH 65mm,
TYING WIRE
COUPLING @ 30M C/C FOR COIL DIA 600mm (BEFORE STRETCH) 2. FOR GENERAL NOTES, LEGEND AND ABBREVIATION
60.3mm O.D. CONTINUOUS TENSION WIRE REFER TO DWG NO. TA-497961, TA-497901.
TOP RAIL 3. ALL FENCE MATERIALS INCLUDING FABRIC, POST
AND FITTINGS COATINGS SHALL CONFORM TO

OF
F E HCIS 2017 SEC-02 SPECIFICATION SECTION 6.3.

- - 4. STRAINING POSTS (CORNER, END, GATE OR TENSION)

CONSENT
BARBED WIRE SHALL BE INSTALLED AT THE BEGINNING AND END
AND AT A MAXIMUM OF 90 METERS INTERVALS OF
(6 LINES)
FENCE FABRIC AND AT CHANGES VERTICAL AND
HORIZONTAL ALIGNMENTS EXCEEDING 22.5°DEFLECTION
ANGLE. STRAINING POSTS SHALL BE BRACED IN THE
300

PLANE OF FENCING TO THE ADJACENT LINE POSTS.

TTEN
POSTS AND BRACES

WRI
5. ALL FENCE AND GATE POSTS SHALL HAVE A
MINIMUM YIELD STRENGTH OF 42000 PSI
( 290 Mpa ) AND SHALL MEET ASTM A529

THE
REQUIREMENTS AS A MINIMUM.
F
6.ALL FENCE AND GATE POSTS, RAILS AND RODS
-

THOUT
SHALL BE INTERNALLY AND EXTERNALLY
GALVANIZED IN ACCORDANCE WITH ASTM F1043 AND
THEN FUSION BOND/POLYESTER COATED INTERNALLY

GHT)

WI
AND EXTERNALLY AS PER ASTM F668 WITH MINIMUM
THICKNESS OF 350 MICRON.
A

HEI

NG
DRAWI
-
3000

C
FABRI
POST OUTSIDE WALL WEIGHT

mm
ITEM
LENGTH DIA (mm) THICKNESS KG/M
2700

2700
LINE POST 3600 88.9 7.62 15.27
(SCH 80)

S
NK

THI
LI
CORNER, END
AND STRAINING 3700 114.3 8.56 22.32

N
CHAI

FROM
POST AND
B GATE POSTS

(
(SCH 80)
-

NED
BRACE RAIL
2800 60.3 3.91 5.44
(SCH 40)

OBTAI
BRACE STRUT
3000 60.3 3.91 5.44
(SCH 40)
FGL
TOP RAIL
6000 60.3 3.91 5.44

BE
(SCH 40)

PART,SHALL
FITTINGS
300

REINFORCEMENT
B C GROUND BEAM
7. ALL FENCE FITTINGS MATERIALS TO BE HOT-DIPPED
D SEE DWG. TA-497965.001
GALV. AFTER COAT WITH APCS 3 (DUPLEX COATING).
-
- -
CORNER OR END LINE POST LINE POST
STRAINING POST INTERMIDIATE WIRE PRODUCTS (AS PER HCIS 2017 SEC-02, SEC. 6.11)
STRAINING POST
8. WIRE FOR CHAIN LINK FABRIC GALV.

N
I
FULL,OR
CHAIN LINK FABRIC TESION TYING BARBED WIRE
CLASS
3000 mm ON CENTERS 3000 mm ON CENTERS WIRE WIRE (GALV.)
MESH WIRE DIA
3000 mm ON CENTERS 3000 mm (FOR INT. STRAINING POST) (FOR INT. STRAINING POST)
(FOR CORNER AND END PANELS) {12.5 GUAGE
(MAX.)
3.76/ 4.50/ 3.76/ 2 STRANDS
C 50
LINE POST 4.16 4.90 4.16 4 POINT BARBS
CORNER OR END PANEL

N
STRAINING PANEL

I
AT 125 SPACING
(@ 3.0M C/C)
(@ 90.0M C/C)

ON
9. COATING OF GALVANIZED POST OR BRACE AT

REPRODUCTI
ENTERING POINT IN CONCRETE SHALL BE BY
CLEANING AFFECTED AREA WITH WIRE BRUSH OR
CHAIN LINK SECURITY FENCE HCIS CATEGORY-4
LIGHT SANDING AND THEN APPLYING ONE COAT OF
M8x35
APCS-113 OR APCS-22. THIS TREATMENT SHOULD
STRETCHER BAND 25x3mm CARRIAGE BOLT
EXTEND 125mm IN TO THE CONCRETE.

10. ALL GATES SHALL MATCH HCIS FENCE HEIGHT


AND SHALL HAVE CONCERTINA WIRE ON TOP.

SAUDIARAMCO.NO
ALL OTHER GATE DETAILES CAN BE FOLLOWED
M8x35mm
AS PER ARAMCO STD DWG. AB-036679.
CARRIAGE BOLT
PLAN
M8x35
POST DIA 88.9mm CARRIAGE BOLT
PLAN PLAN
TRUSS ROD POST DIA 114.3mm
DIA 10mm BRACE CUP 60
END BAND 114
POST DIA 114.3mm
PLAN WINDING BRACKET

OF
TENSION WIRE
TRUSS ROD REFERENCE DRAWINGS

PROPERTY
STRETCHER BAR TIGHTENER TD-896993
DWG. CONTROL FOR J.O 10-02029-0003
20x6mm
FENCE FOUNDATION DETAILS TA-497965.001
END BAND 90

M10x100 EYE BOLT

BRACE RAIL

SOLE
M8x35 CARRIAGE BOLT END BAND 114 END BAND 114
CORNER POST 60.3mm O.D.
114.3mm DIA

POST DIA 14.3mm

THE
C D E T A I L D D E T A I L
A D E T A I L B D E T A I L

ARE
SCALE NTS
SCALE NTS
SCALE NTS SCALE NTS -
- (BRACE CUP ELEVATION)
- - (WINDING BRACKET ELEVATION)

N
(STRETCHER BAR ELEVATION) (STRETCHER BAR ELEVATION)

HEREI
CONCERTINA BARBED
HOLES IN HORIZONTAL
TAPE 600mm DIA
FLANGE

NED
(BEFORE STRETCH) SCALE: NTS

CONTAI
LOCK WIRE STRAINING/LINE POST

REVISION VALIDATION
MS T SECTION
+290
+350

THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


50x50x5mm REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

BRACE STRUT @

ON
10-02029-0003-001
EVERY 9.00M C/C

NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)

OUTSIDE INSIDE ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE


+1500

MAS VKP
04/15/18 04/15/18

REV.NO. DATE REVISION DESCRIPTION

I
END BAND DIA 114 00 04/15/18 ISSUED FOR CONSTRUCTION

BOLT/NUT

THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
M8x110mm END POST
10-02029-0003 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY

AND
LINE POST TIOP RAIL
DRAWING TYPE
FOR FOUNDATION
STRUCTURAL DET/ELEV/LAYOUT/PLN SDT
SEE DWG.NO. TA-149065.001

NG
HCIS CATEGORY-4 FENCE

DRAWI
E D E T A I L F D E T A I L GAS GATHERING MANFS. F/LINES
SCALE NTS HAWIYAH SAUDI ARABIA
SCALE NTS
-

S
- (STRAINING POST-EXTENSION ARM SIDE ELEVATION) SECTION FOR BRACE STRUT PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
(EXTENSION ARM SIDE ELEVATION)
H92 M TA-497905 001 00
Saudi Aramco 2615 ENG. (05/05)

RESTRICTED VECTOR CADD-01