MILTON ROY INDIA (P) LTD.

Metering Pumps

Instruction
Manual
M -Series
This Manual should be made available to persons
responsible for Installation, Operation and Maintenance.

M-
Pump Model No.........................................................................

Serial No....................................................................................

LPH
Capacity.....................................................................................
Kg/cm 2
Pressure....................................................................................

4, Rajarajan Street, Visalakshi Nagar,


Ekkaduthangal, Chennai - 600 097, India.
Telephone : (044)-22254000 - 3
Fax : 91-44-22254004 E-mail : miltonroyindia@vsnl.net
Web : www.miltonroyindia.com

Issue Date : 03/2005


M - Series Pumps

TABLE OF CONTENTS
WARRANTY Page No.

I. UNPACKING 1

II. LOCATION AND MOUNTING 1

III. ELECTRICAL AND DRIVE 1

IV. LUBRICATION 1

V. PLUMBING CONFIGURATION 1

VI. LIQUID HANDLING ASSEMBLY 1

VII. PUMP OPERATION 3

VIII. MAINTENANCE 4

TROUBLE SHOOTING GUIDE 5

SERIES M DRIVE ASSEMBLY PARTS LIST 7

LIQUID HANDLING ASSEMBLY PARTS LIST 9

MILTON ROY INDIA (P) LTD.


M - Series Pumps

METERING PUMP PRODUCTS TWELVE MONTH


LIMITED WARRANTY
Milton Roy India (P) Ltd., warrants its metering pump products against defects in workmanship or materials for one
year under normal use from the date of shipment from our warehouse or the warehouse of our agent. All metering
pump components are warranted for one year, except that warranties on equipment and accessories furnished with
the pump but manufactured by others are limited to the warranties offered by the manufacturers of their respective
products. This warranty is not extended to electronic control devices supplied with a Milton Roy India (P) Ltd.,
metering pump. These items are covered by the warranties offered by the manufacturer for Electronic Controls and
Actuators.
All obligations and liabilities under this warranty are limited to refunding, repairing or replacing (at our option), f.o.b,
our plant, such allegedly defective units as are returned to our plant, carrier charges prepaid. Repairs or
replacements are made subject to factory inspection of returned items.
This warranty does not extend to damage by corrosion or erosion. The materials of construction offered are
recommendations subject in all cases to verification and acceptance by the customer. These recommendations,
based on previous Company experience and best available information, do not constitute guarantees against wear
or chemical action.
Expressly excluded from this warranty are defects caused by misuse, abuse, or improper application, employment,
or operation of the unit. Expendable items and damage resulting from unauthorised repair are not covered by this
warranty. No liability for consequential damages or reinstallation labour is accepted. Milton Roy India (P) Ltd., will
not assume responsibility for contingent liability for alleged failure of its products.

RETURNING PUMPS TO THE FACTORY

Pumps will not be accepted for repair without a written consent from the Factory Service Department. Pumps
returned to the Factory for repairs should be clearly labeled to indicate the liquid being pumped. Process liquid
should be flushed from the pump liquid end and oil should be drained from the pump housing before the pump is
shipped.
NOTE
These safety precautions will aid the troubleshooting and repair procedure and preclude serious injury to
repair personnel from hazardous residue in pump liquid end.
All inquiries or parts orders should be addressed to your local Milton Roy India (P) Ltd., representatives or sent to :

MILTON ROY INDIA (P) Ltd.,


NO.: 4, RAJARAJAN STREET, VISALAKSHI NAGAR
EKKADUTHANGAL, MADRAS - 600 097.
PHONE NO.: (044) - 22254000 - 3
FAX NO.: 91-44-22254004

MILTON ROY INDIA (P) LTD.


M-Series Pumps
I. UNPACKING and while pumping into open tanks. To prevent this
Remove tubing, injection check valve, pressure relief condition from occurring it is necessary to maintain
valve and foot valve which are supplied loose. Notify approximately 25 PSI (10 PSI for M-13 & M-14) back
Factory and Insurance Company immediately if there are pressure across the pump. This is achieved by a
any sings of damage to the metering pump or parts. spring loaded injection check/antisyphon valve.
Consult ALMI factory for injection check/antisyphon
CAUTION valves with increased back pressure ratings.
3. If chemical level in flooded suction installations
When pumping chemicals make certain that all are more than 3 metres consult factory.
tubing is securely attached to the fittings. It is 4. Fluid Connections - M series metering pumps are
recommended that tubing or pipe lines be shielded equipped with LDPE flexible tubing for both suction
to prevent possible injury in case of rupture or and discharge. In case you wish to use rigid piping
accidental damage. Always wear protective face contact factory for fittings with NPT threads. Following
shield and clothing when working on or near a precautions should be taken.
chemical metering pump. All M Series pumps are * Pressure test all plumbing before use to guard
motor driven mechanical pumps. Your pump has against leaks.
been equipped with a pressure relief valve supplied * Prevent thread sealant from getting inside
by MRIPL & you have to install the same on the head plumbing.
of pump before start-up. * Install a ball valve in the suction side of flooded
suction installation to simplify maintenance.
II. LOCATION AND MOUNTING * A foot valve is a must in suction lift installations.
* Do not use teflon tape on flexible tubing
1. Locate the pump in an area that is convenient to
connectors.
both chemical injection point and electrical
* Do not use pipe wrenches on flexible tubing
supply. MRIPL chemical metering pumps should
connectors.
not be subjected to continuous high temperature
over 500 C
CAUTION
2. Mount the pump at a convenient operating height
on a firm foundation. Be sure installation does not constitute a cross
III. ELECTRICAL AND DRIVE connection. Check local plumbing code.
The pump is driven by a 0.5 H.P., 1440 RPM squirrel
cage induction motor. The input power supply is 415V VI. LIQUID HANDLING ASSEMBLY
3 phase 50 C/S. The drive consists of a speed
reduction by means of a worm and worm wheel. The A. Installing Injection Check Valve
worm is connected to the motor by a love-joy
coupling. 1. The injection check/antisyphon valve should
IV. LUBRICATION always be installed as close as possible to the
Before operating the pump check oil drain plug for point of chemical injection at the very end of the
tightness and fill unit with 250 ml. of SAE 140 Grade tubing run.
Oil (Servo Gear HP-140 of Indian Oil or equivalent).
Check oil level using dip-stick provided with the filler 2. Purpose of injection check/antisyphon valve is to
plug. prevent backflow from treated line. It also
V. PLUMBING CONFIGURTION provides the back pressure required for the
pump.
1. Figures 1 & 2 show typical chemical metering
pump installations. Note location of injection
check valve which is most important. Refer to 3. A 1/2" NPT female fitting with sufficient depth will
liquid handling assembly instructions section accept the injection check/antisyphon valve.
regarding installation of injection check valve.
4. In order to ensure correct seating of the ball inside
2. Back Pressure Requirement
the check valve, the injection check/antisyphon
All metering pumps are prone to overpumping
valve should be installed vertically upwards.
(excessive output) at low discharge pressure

MILTON ROY INDIA (P) LTD.


1
M-Series Pumps

5. Maximum pump pressure rating is reduced with 5. Slide down the coupling nut until threads are engaged.
spring installed in injection check/antisyphon valve. Tighten by hand until tubing is held securely in place.
Remove spring if pressure at injection point is more
than 20 PSI.
Excessive force will crack or distort fittings.
B. Installing Pressure Relief Valve DO NOT USE PIPE WRENCH

1. MRIPL PRV consists of a pressure relief valve with a


mounting adaptor.
6. Follow the same procedure for connecting tubing to
2. Screw in adaptor on the discharge valve plug. Take injection valve.
care to see that the Quad seal sits on the taper nozzle.
Do not use teflon tape. Screw in the PRV into the D. Connecting Suction Tubing
adapter taking care to see that the quad seal in
1. Cut Suction tubing to length such that the foot valve
position.
hangs just above the bottom of the chemical container.
C. Connecting Discharge Tubing Maximum recommended vertical suction lift 5 ft.
(1.5m).
1. Cut tubing to length needed for discharge line.
2. Follow same procedure (see C) in connecting suction
2. Route tubing from injection check valve to chemical tubing to suction valve and foot valve.
metering pump making sure it does not touch hot
surfaces, sharp surfaces, or is bent so sharply that it 3. If a suction tube straightener is desired, one may be
kinks. fabricated from a 3 ft. (1m) piece of 1/2" Schedule 80
PVC pipe.
3. Slide small end of coupling nut onto tubing.
4. In case of flooded suction use a tubing connector with
4. Push tubing over tapped nozzle of discharge valve 1/2 NPT threads. This is available from MRIPL as an
housing so that tubing flares out and reaches the optional accessory.
shoulder. If tubing is stiff from cold, dip end in hot
water.

SUCTION LIFT INSTALLATION FLOODED SUCTION INSTALLATION


helpful when pumping
at very low rate

Fig. 1 Fig. 2
MILTON ROY INDIA (P) LTD.
2
M-Series Pumps
VII PUMP OPERATION (0) mark on the dial when the knob is turned counter-
A. Priming clockwise as far as it will go. This is the zero output
position. The maximum output position. The maximum
Priming can be done only against atmospheric
output position is reached by turning this knob fully
pressure when using a suction lift installation. Flooded
clockwise to 100% setting on dial. Output adjustment
suction installations will allow the unit to prime itself
should be done while the unit is running.
even under pressure.
C. Output Adjustment knob Setting
1. Temporarily remove tubing from injection check
valve and hold the end of tubing so that it is above With the pump operating, turn the output adjustment knob
pump level. counterclockwise until no stroking action is felt when
holding onto the knobs. At the point where stroking action
2. Set pump at 100% stroke and start pump. stops the line on the knob should be directly over the zero
3. As soon as chemical is visible through translucent mark on the dial. If alignment is not correct, knob position
discharge tubing just past the discharge valve, on shaft should be adjusted as follows.
stop the pump. 1. Loosen 2 Nos. set screws on the knob with suitable
4. Pump is now primed. Allen-wrench and remove the knob.
5. Reconnect tubing to injection check valve. 2. Loosen Lock knob.
Note : 3. With a griplier adjust shaft until a point is reached
(a) Pump is normally self-priming if suction lift is no where stroking action just ceases and can go longer
more than 5 ft. (1.5m) and the above steps (A1 be felt when grasping shaft and stop the pump.
thru A3) are followed. 4. Place knob on shaft. Carefully line knob up so that
(b) If the pump does not self prime, remove discharge knob pointer is directly over the zero marking on the
valve housing and ball and pour water or dial.
chemical slowly into discharge port until it is filled. 5. Taking care not to move shaft or knob alignment,
Follow steps A2 thru A5 thereafter. tighten both set-screws.
In all cases priming will be assisted by releasing or 6. Recheck alignment results.
reducing pressure on the pump. This is best D. Calibration
accomplished by pulling the lever of the ALMI Pump output calibration can be easily done if required.
Pressure Relief Valve. The pump is best calibrated after installation by using a
B. Output Adjustment stopwatch to measure the time required to remove a
Pump output is adjusted using the knob located at the known volume of liquid from a tank (fig.4). Proper setting
top of the pump (fig.3). The lock knob holds the shaft of the pump's zero output position should be verified
to prevent charge of setting. Before adjusting the before calibration and is explained is Section B.
pump should be running. The dial under the knob
represents "% of total output" and provides accurate
output adjustment above the 10% setting. The knob is
set properly if the line on the knob lines up the zero

Fig. 3
MILTON ROY INDIA (P) LTD.
3
M-Series Pumps
VIII MAINTENANCE 6. Remove pump head by unscrewing the four/six head
A. Lubricant Change retaining screws holding the head to the spacer.
The m series drive train is oil lubricated. Replace oil 7. Start the pump. With unit running at 100% output,
every 1000hrs. of running with approximately 250 ml. unscrew and remove and old Liquidfram.
of SAE 140 Grade Oil (Servo Gear HP-140 of Indian
8. With pump still running, set output adjustment knob
Oil or equivalent). Check oil level periodically using
back to 90% for models M-09, M-10, M-11 and M-12,
dip-stick and top-up as required.
70% for model M-13 and 50% for Model M-14.
B. Liquifram Replacement
9. Without changing these output settings, screw new
Always wear protective clothing and face shield Liquifram in place.
when working on or near a chemical metering pump. 10. Stop the pump. Rotate the shaft at Love-joy coupling
or Motor fan (after removing fanguard) and make sure
diaphragm is fully retracted. Then check Liquifram
1. Disconnect suction supply line and shut off to alignment by using a straight edge held firmly against
prevent chemical spill. the spacer (take care not to scratch the sealing flange
2. Operate pump until pump head is empited of of Teflon-faced Liquiframs). Centre of Liquifram
chemical. set output adjustment knob at 100% by should be flush with outer edges of spacer (fig. 5).
turning knob fully clockwise.
11. With new liquifram installed, turn on pump and set
3. Stop the pump.
knob at 100% output position. Reinstall pump head
4. Release pressure from discharge line by pulling making sure the part number stamped on the face of
the knob on the PRV. the head is in upright position. Tighten the four/six
5. Disconnect discharge line. Be prepared to catch retaining screws in a criss cross pattern.
excess chemical during this procedure.

DATA SHEET FOR METERING PUMP

MODEL M SERIES

TYPE MECHANICALLY ACTUATED DIAPHRAGM TYPE

MODEL M-09 M-10 M-11 M-12 M-13 M-14

MAX FLOW (IN LPH) 5 10 17 30 50 100

MAX PRESSURE (KG/SQCM) 15 15 12 10 5 3

STROKE PER MINUTE 50 100 144 144 144 144

LINEAR SPEED (M/MIN) 0.4 0.8 1.152 1.152 1.152 1.152

4 MILTON ROY INDIA (P) LTD.


TROUBLE SHOOTING GUIDE
Problem Cause Remedy
Solution drips from hole in Liquifram is ruptured Replace Liquifram. See Liquifram Replacement
spacer instructions in maintenance section of this manual
Liquifram does not move Output adjustment knob is set at zero With pump running, rotate output adjustment knob to a
higher setting.
Power is off Check power supply.
Solution is too viscous Dilute solution.
Injection into excessive pressure. Check and clean valves if clogged. Check system
pressure against maximum injection pressure rating pump. If
discharge pressure is within 20 PSI of pump's m a x i m u m
rating, remove spring in injection check /antisyphon valve.
Liquifram moves, but no solution Trapped air in pump head Operate pump of 100% output setting. Release
is pumped pressure on pump discharge. Follow priming
instructions. Operate pump for a few minutes to purge
head and valves of air.
Suction lift is too high Reduce suction lift or arrange pump and tank for
flooded suction installation.
Loop in suction line permits air trap on Straighten suction tubing.
suction side
Improperly installed, or dirty valve seats Refer liquid Handling Assembly instructions. Clean and
reassemble valves.
Air in suction line. Tighten suction valve fitting. Replace if necessary. Check for
air leaks throughout suction line.
Pumps air bubbles or air. Suction tubing has leaks or pin holes. Replace suction tubing.
Improperly installed, or dirty valve seats. Refer liquid Handling Assembly instruction. Clean and
reassemble valves.
Suction lift is too high. Reduce suction lift or arrange pump and tank for flooded
suction installation.
Solution supply is exhausted. Refill solution container.
Foot valve and strainer assembly is clogged Clean foot valve assembly.
Pumps does not start under low Voltage Check your power supply
rated pressure Pressure rise due to discharge line Clean discharge line or dilute solution.
or viscosity of solution.
Clogged injection check/antisyphon Refer Liquid Handling Assembly instruction. Clean and
valve.. reassemble valves.
Suction tubing collapses Foot valve and strainer assembly is Refer Liquid Handling Assembly instruction. Clean and
clogged. reassemble valves. Replace strainer if necessary.
Excessive pump output output adjustment knob is improperly With pump running turn knob counter clockwise until
set. pump stops stroking. Line on knob should be directly
over the zero mark on the dial. If setting is off, adjust by
following Output Adjustment knob setting instructions
in this manual.
Very low pressure at injection point Install injection check/antisyphon valve on pump.
Excessive positive suction head. When flooded suction installation is used, chemical
supply should be no more than 20 feet (6 metres) above
pump when using standard injection check/ antisypon
valve and zero discharge pressure. Alter location of
pump or consult factory.

5
DRIVE ASSEMBLY - M PUMP

KEY NO PART NO DESCRIPTION QTY

1 13531 10-24 X 3/4" PAN HEAD SCREW 12 (M14) & 8 ( others)

2 130420 SPACER ADAPTOR (M-14) ONLY 1

3 131120S SPACER (M-09, M-10, M-11) 1SET

3 131220S SPACER (M-12) 1SET

3 131320S SPACER (M-13, M-14) 1SET

4 130552 GASKET SPACER 1

5 133525 SPRING 1

5A 11531 ADDITIONAL SPRING (M-12) ONLY 1

6 11711 RETAINER PLATE 1

7 130631 LIQUIFRAM SHAFT 1

8 133626 DOWEL 5 X 15 2

9 130713N GEAR PLATE 1

10 131826 BALL BEARING (6200) 1

11 131511 WIDE CAM SPACER 1

12 131444 WORM WHEEL (M-11,M-12,M-13,M-14) 1

12 131344 WORM WHEEL (M-10) 1

12 131244 WORM WHEEL (M-09) 1

13 134026 CAM BEARING (6204) 1

15 131926 BALL BEARING (6201) 1

16 132011N BEARING CAP 1

17 130931S CAM SHAFT ASSY FOR M 1SET

18 131526 BALL BEARING (6000) 1

19 131722 WORM SHAFT (M-11,M-12,M-13,M-14) 1

19 131522 WORM SHAFT (M-10) 1

19 131622 WORM SHAFT (M-09) 1

20 131726 BALL BEARING (6001) 1

21 132331 ADJUSTMENT SHAFT 1


22 132311N ADJUSTMENT STOP 1

22A 134052 GROMMET FOR ADJUSTMENT STOP 'M' 1

23 134511 DIAL (M-09,M-10, M-11) 1

23 134911 DIAL (M-12) 1

23 134811 DIAL (M-13, M-14) 1

24 132431S ADJUSTMENT KNOB WITH GRUB SCREW 1 SET

25 132613 HOUSING 1

26 152131S VENT CAP WITH GASKET 1SET

27 132531 LOCK KNOB 'M' 1

27A 132641 LOCK KNOB INSERT 'M' 1

28 132841S DRAIN PLUG WITH O-RING 1SET

29 133721 MOUNTING BASE (STD MOTOR) - 0.5 HP 1

29 133821 MOUNTING BASE (FLP MOTOR) - 0.5 HP 1

30 135531 STUD SS M8 X 35 (FT) 4

31 126231 NUT M8 4

32 11252 OIL SEAL LIQUIFRAM SHAFT 1

33 133120 COUPLING (STD MOTOR) - 0.5 HP 1

33 133220S COUPLING (FLP MOTOR) - 0.5 HP WITH GRUB SCREW 1 SET

34 132952N OIL SEAL 1

34A 133011N OIL SEAL HOLDER 1

35 130811N BEARING RING 1

36 134931 CSK SCREW 3/16" X 1/2" 8

37 134831S ALLEN SCREW M5 X 30 WITH SPRING WASHER 4 SET

39 M01677S HEX BOLT M6 X 35 WITH NUT AND WASHER 4 SET


HEX BOLT M8 X 45 WITH NUT AND WASHER ( 0.5 HP FLP
39 M01267S 4 SET
MOTOR)
42 183511 OIL LEVEL INDICATOR 1

43 130713S GEAR PLATE ASSEMBLY M-09 1SET

43 130713D GEAR PLATE ASSEMBLY - M-10 1SET

43 130713T GEAR PLATE ASSEMBLY -M11, M12, M13, M14 1SET


LIQUID END ASSY FOR PUMPS WITH PP HEAD
M-09,M-
KEY NO DESCRIPTION M-12 M-13 M-14 QTY
10,M-11.
2 SPRING 37341 37341 37341 37341 1

3 BALL CERAMIC 10338 10338 10338 10138 3

4 RING SEAL TEFLON 902079 902079 902079 902179N 3

5 SUCTION VALVE SEAT ASSY 902667 902667 902667 902967 2SET

6 QUAD SEAL 905755 905755 905755 905755 2

7 TUBING 10142 I 10142 I 10142 I 10142 I 13FT

8 DISCHARGE VALVE HOUSING ASSY 902767 902767 902767 903067 1SET

9 3/16 X 3/4" PAN HEAD SCREW 13531 13531 13531 NA 4

10 LIQUIFARM (DIAPHRAGM) 30917 31420 31419 25719 1

11 HEAD 900568 900468 900368N 900268 1

12 PRV ADAPTOR 904867N 904867N 904867N 904867N 1

14 Y-STRAINER ASSY 913267S 913267S 913267S 913267S 1SET

15 ANTISYPHON VALVE ASSY 906267 906267 906267 906467 1SET

16 FOOT VALVE ASSY 907067 907067 907067 907167 1SET

17 PRESSURE RELIEF VALVE 904767N 904767N 904767N 904767N 1

18 M6 X 60 HEX BOLT,NUT WITH WASHER NA NA NA M01639S 6 SETS

LIQUID END ASSY FOR PUMPS WITH PVDF HEAD WITH PVC FITTING
M-09,M-
KEY NO DESCRIPTION M-12 M-13 M-14 QTY
10,M-11
2 SPRING 37341 37341 37341 37341 1

3 BALL CERAMIC 10338 10338 10338 10138 3

4 RING SEAL TEFLON 902079 902079 902079 902179N 3

5 SUCTION VALVE SEAT ASSY 902667 902667 902667 902967 2SET

6 QUAD SEAL 905755 905755 905755 905755 2

7 TUBING 10142 I 10142 I 10142 I 10142 I 13FT

8 DISCHARGE VALVE HOUSING ASSY 902767 902767 902767 903067 1SET

9 3/16 X 3/4" PAN HEAD SCREW 13531 13531 13531 NA 4

10 LIQUIFARM (DIAPHRAGM) 30917 31420 31419 25719 1

11 HEAD 29611M 27214M 31053M 32234M 1

12 PRV ADAPTOR 904867N 904867N 904867N 904867N 1

14 Y-STRAINER ASSY 913267S 913267S 913267S 913267S 1SET

14A ONLINE STRAINER ASSY 909867S 909867S 909867S 909867S 1SET

15 ANTISYPHON VALVE ASSY 906267 906267 906267 906467 1SET

16 FOOT VALVE ASSY 907067 907067 907067 907167 1SET

17 PRESSURE RELIEF VALVE 904767N 904767N 904767N 904767N 1

18 M6 X 60 HEX BOLT,NUT WITH WASHER NA NA NA M01639S 6 SETS


LIQUID END ASSY FOR PUMPS WITH SS HEAD
M-09,M-
KEY NO DESCRIPTION M-12 M-13 M-14 QTY
10,M-11.
2 SPRING 37341 37341 37341 37341 1

3 BALL CERAMIC 10338 10338 10338 10138 3

4 RING SEAL TEFLON 902079 902079 902079 902179N 3

5 SUCTION VALVE SEAT ASSY 902632S 902632S 902632S 902932S 2SET

6 QUAD SEAL 905755 905755 905755 905755 2

7 TUBING 10142 I 10142 I 10142 I 10142 I 13FT

8 DISCHARGE VALVE HOUSING ASSY 902732S 902732S 902732S 903032S 1SET

9 3/16 X 3/4" PAN HEAD SCREW 13531 13531 13531 NA 4

10 LIQUIFARM (DIAPHRAGM) 30917 31420 31419 25719 1

11 HEAD 900532 900432 900332N 900232N 1

12 PRV ADAPTOR 904832N 904832N 904832N 904832N 1

14 Y-STRAINER ASSY 913232 913232 913232 913232 1SET

15 ANTISYPHON VALVE ASSY 906232 906232 906232 906432 1SET

16 FOOT VALVE ASSY 907032 907032 907032 907132 1SET

17 PRESSURE RELIEF VALVE 904732N 904732N 904732N 904732N 1

18 M6 X 40 HEX BOLT,NUT WITH WASHER NA NA NA 133431S 6 SETS

LIQUID END ASSY FOR PUMPS WITH PVC HEAD


M-09,M-
KEY NO DESCRIPTION M-12 M-13 M-14 QTY
10,M-11.
2 SPRING 37341 37341 37341 37341 1

3 BALL CERAMIC 10338 10338 10338 10138 3

4 RING SEAL TEFLON 902079 902079 902079 902179N 3

5 SUCTION VALVE SEAT ASSY 902667 902667 902667 902967 2SET

6 QUAD SEAL 905755 905755 905755 905755 2

7 TUBING 10142 I 10142 I 10142 I 10142 I 13FT

8 DISCHARGE VALVE HOUSING ASSY 902767 902767 902767 903067 1SET

9 3/16 X 3/4" PAN HEAD SCREW 13531 13531 13531 NA 4

10 LIQUIFARM (DIAPHRAGM) 30917 31420 31419 25719 1

11 HEAD 900567 900467 900367N 900267 1

12 PRV ADAPTOR 904867N 904867N 904867N 904867N 1

14 Y-STRAINER ASSY 913267S 913267S 913267S 913267S 1SET

14A ONLINE STRAINER ASSY 909867S 909867S 909867S 909867S 1SET

15 ANTISYPHON VALVE ASSY 906267 906267 906267 906467 1SET

16 FOOT VALVE ASSY 907067 907067 907067 907167 1SET

17 PRESSURE RELIEF VALVE 904767N 904767N 904767N 904767N 1

18 M6 X 60 HEX BOLT,NUT WITH WASHER NA NA NA M01335S 6 SETS